Loading...
HomeMy WebLinkAboutFile Documents.100 E Dean St.0043-2021-BRES (7) e e rn e n t ENVIRONMENTAL INC 189 County Rd. 135 Glenwood Springs, CO 81601 josh@elementconsults.com (970) 274-3139 Property Address Asbestos Sampling Report 100 E. Dean St. Unit 3A Date: 01/13/2021 Aspen, CO 81611 H Date of Inspection: 01/12/2021 Client: Element Environmental Project#: 37Degrees 011221 v37 Degrees E 15 S. Willow Ct � Aspen, CO 81611 p Client Job Name Dean Street Attn: Jacob Pipe TABLE OF CONTEIv I O 1.0 -Scope of Work 2.0 -Sampling Requirements °C O 3.0 -Sampling Methodology N Building Inspector: 4.0 - Laboratory 5.0 -Suspect Materials Sampled Ellen Johnson 6.0 -Table of Results 7.0 - Description of Sampling Area CDPHE#23799 8.0 - Conclusion 9.0 - Lab Report 10.0 - Certificates Joshua Johnson CDPHE#18401 Asbestos Samples Analyzed: 3 Positive Asbestos Samples: 1 N I, , 1 ED Q 02/25/2021 ASPEN BUILDING DEPARTMENT 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: 2.1-Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.-5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2-Miscellaneous materials- Minimum of 2 samples 2.3-Thermal Systems Insulation(TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are segregated into separate homogenous areas. The size is determined and then samples are taken. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The samples are taken in a random numerical sequence. 4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 23799, performed the inspection. The findings were reviewed by Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or<1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional "point count" performed to be considered less than 1% and not be regulated by the CDPHE. The lab's documents with analyses and findings are found below. RECEIVED e e m e n t 189 county rd 135 glenwood springs,co 81601 g7o.2743139 21 www.elementconsults.com Project#-37Degrees 011221 ENVIRONMENTAL INC LEAD ASBESTOS ' I • �TDIN "ffMENT 3 5.0- SUSPECT MATERIALS SAMPLES • Drywall • Joint Compound • Texture • Tape 6.0- TABLE OF RESULTS HOMOGENOUS DESCRIPTION OF AREA ACM CATEGORY NUMBER APPROXIMATE ACM ASSESSMENT CATEGORIES %AND TYPE OF AREA OF SQ.FT.* ASBESTOS FOUND I SAMPLES (A) Skip Trowel Texture Surfacing 3 —400sq.ft. No.7—Friable ACM with low 2%Chrysotile in 1 of 3 potential for damage Samples Key: ACM Assessment Categories: 1-Damaged or significantly damaged Thermal Systems Insulation 6-ACM with potential for significant damage (TSI)ACM 7-Friable ACM with low potential for damage 2-Damaged friable surfacing ACM Other-ACM not classified in the above Assessment Categories 3-Significantly damaged friable Surfacing ACM N/A-Not Applicable 4-Damaged or significantly damaged friable Miscellaneous ACM 5-ACM with potential for damage *Square footage is estimated and not for bidding purposes 7.0- DESCRIPTION OF SAMPLING AREA • Skip Trowel texture on the ceiling and walls for a remodel. The remodel included changing out the ceiling lights, adding a larger exterior window, and some interior doors. RECEIVED e e m ent 8g county rd 135 glenwood springs,co 81601 970.274.3139 21 www.elementconsults.com Project#-37Degrees 011221 ENVIRONMENTAL "d LEAD ASBESTOS HAM bUltUIN ''ffMENT 4 8.0- CONCLUSION The area on the Table of Results in Red contains asbestos: • Skip Trowel Texture on the ceiling and around the doors of the mechanical room and exterior door by the deck These materials become friable when they are removed. If these materials are to be disturbed or removed, the materials MUST be remediated in accordance with the CDPHE Regulation No. 8 by a licensed abatement contractor. For residential projects over 32 square feet of surfacing material,50 linear feet of pipe insulation, or 55 gallon drum of waste; and for commercial projects with 160 square feet of surfacing material, 260 linear feet of pipe insulation,or a 55 gallon drum of waste, a permit is required.The permit is through the CDPHE.Along with the permit,a final air clearance is required by a certified Air Monitoring Specialist. For projects over 3,000 square feet, a Project Design and Project Manager is required. Element Environmental is certified and can perform Final Clearances, Project Design, and Project Management if required.All work performed MUST follow all EPA,State Regulation 8, and OSHA regulations to protect the general public,the client,and the workers. Sincerely, Joshua Johnson e e rn en 4 18g county rd i35 glenwood springs,co 81E _7 .27Z '3) E D www,eLementconsults.com Project#-37Degrees 011221 ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 �2 �,To21 ASPEN BUILDING DEPARTMENT 5 9.0- LAB REPORT I► tiff eurofins CEI ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for Element Environmental LLC CLIENT PROJECT: 37 Degrees 011220 LAB CODE: B210588 TEST METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORT DATE: 01/13/21 TOTAL SAMPLES ANALYZED: 3 #SAMPLES>1%ASBESTOS: 1 a e e m e n 189 county rd 135 glenwood springs,co 81E -27 ,.277 www.eLementconsuLts.com 6c� Project#-37Degrees 011221 ENVIRONMENTAL nVC LEAD ASBESTOS HAZ 0 ASPEN BUILDING DEPARTMENT 6 Asbestos Report Summary eurofins .• By: POLARIZING LIGHT MICROSCOPY CEI PROJECT: 37 Degrees 011220 LAB CODE: B210588 METHOD: EPA 600/R93/116 and EPA 600/ M4-82/020 ASBESTOS Client ID Layer Lab ID Color Sample Description 3A Al Layer 1 67711 White,Off-white Skip Trowel None Detected Layer 2 B7711 Off-white Drywall None Detected 3A A2 Layer 1 B7712 White,Off-white Skip Trowel Chrysotile 2 Layer 2 B7712 Off-white Drywall None Detected 3A A3 Layer 1 B7713 White,Off-white Skip Trowel None Detected Layer 2 B7713 Off-white Drywall None Detected Page 1 of 1 e e m en -L. 189 county rd 135 glenwood springs,co 81( 7 ,.277 "3) E D www.elementconsults.com Project#-37Degrees 011221 ENVIRONMENTAL/NC LEAD ASBESTOS HAZ 0 ASPEN BUILDING DEPARTMENT 7 tiff° eurofins ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY CE I Client: Element Environmental LLC Lab Code: B210588 189 CR 135 Date Received: 01-13-21 Glenwood Springs, CO 81601 Date Analyzed: 01-13-21 Date Reported: 01-13-21 Project: 37 Degrees 011220 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous % 3A Al Skip Trowel Heterogeneous 35% Calc Carb None Detected Layer 1 White,Off-white 60% Binder B7711 Non-fibrous 5% Paint Bound Layer 2 Drywall Heterogeneous 20% Cellulose 80% Gypsum None Detected B7711 Off-white Fibrous Bound 3A A2 Skip Trowel Heterogeneous 33% Calc Carb 2%Chrysotile Layer 1 White,Off-white 60% Binder B7712 Non-fibrous 5% Paint Bound Layer 2 Drywall Heterogeneous 20% Cellulose 80% Gypsum None Detected B7712 Off-white Fibrous Bound 3A A3 Skip Trowel Heterogeneous 35% Calc Carb None Detected Layer 1 White,Off-white 60% Binder B7713 Non-fibrous 5% Paint Bound Layer 2 Drywall Heterogeneous 20% Cellulose 80% Gypsum None Detected B7713 Off-white Fibrous Bound Page 1 of 2 e e m en t 18g county rd 135 glenwood springs,co 81E 7 .27z "3) • www.elementconsults.com Project#-37Degrees 011221 ENVIRONMENTAL/NC LEAD ASBESTOS HAZOT 0 i2/2S7To 21 ASPEN BUILDING DEPARTMENT 8 ,!• eurofins CEI LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb =Calcium Carbonate METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORTING LIMIT: <1%by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points REGULATORY LIMIT: >1%by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID and sample description. ANALYST: i G /vim, . APPROVED BY: lc:,.,,✓A� / ------ -- McLane Brown Tianbao Bai,Ph.D.,CIH Laboratory Director NVIAp TESTING NVLAP LAB CODE 101768-0 Page2of2 10.0- CERTIFICATES �++ e e m e n - 189 county rd 135 glenwood springs,co 81(^' 7 ,.27L si3) 1•�D www.elementconsults.com I•w Project#-37Degrees 011221 ENVIRONMENTAL/NC LEAD ASBESTOS HAZ 0 ASPEN BUILDING DEPARTMENT 9 Za�{'IT st "�4`°'J"1 r 't°yZ.'J�+ y# y�.'Mi 00,..41v44 ,.. at �� e r s 4Aee Ss wm 1.4 �.. n v, , .,,, ' i y aaI� �a ' � i 1'',,7 of 'l/vvi 1b:* �a Y � ,�. t t111 � � �=k� ��^�'1 ��.e5 +,�'F •, yr 4 1� X �� t f ' u� � � s „Ill isi -,•.)„„ -e', ( oq Colorado Department Colorado Deputy!em �'p, of Public Health fPublicHeallh ' .e and Environment and Favirormamt ,, i "3, ASBESTOS ASBESTOS , CERTIFICATION* CERTIFICATION* ,,j' This certifies Mat - 1 his ours I,gnat . lA r �(` Joshua Jay Johnson ° Ellen.Tohnson '',.I i Certification No.:23799 y �, Certification No.,18001 � J has met the requirements of 25 7 507,C.R.S.and Air Quality Control - � has met the requirements of 25-7-507,C.RS.and Air Quality Control - s. '. Commission Regulation No 8,Part B,and is hereby certified by the r;:i'ii.13e� Commission Regulation No.8,Part B,and is hereby certified by the state of Colorado m the follote mg dmetplme: state of Colorado in the follomng discipline. a cry - ( Building Inspector* �. Building Inspector* c �. 1 Issued- July 08,2021 y� Issued: August 21.2020 Ls p Jul 19,2021 Exptro August 01,2021 .I y- slim u�v..,mx+to _- �1/ 2 - "Yt ,edHIN�„e�m lw b�.v. .,�,..r,1,,.,M, n i o,aetr Q - __ -.,yam l�W..nn, F' SL.'tc '.� i 7 d I^. 5 ,F. �s ,yq-Ti;,,,,.,i,v4 �i1r R�tM� ',,v / '.t :x2 r ,^`,, f A .la Colorado Department of Public Health and Environment ASBESTOS CONSULTING FIRM This certifies that Element Environmental LLC Registration No.:ACF-21640 • has met the registration requirements of 25-7-507,C.R.S.and the Air Quality Control Commission Regulation No.8,Part B.and is hereby authorized to pert asbestos consulting activities as required under Regulation No 8,Part B,in the state of Colorado. Issued: January 09,2020 Expires: January 25,2021ii----) aunemrsarmaa9n.xuu. ' arat e e m e n 189 county rd 135 glenwood springs,co 81e -7 ,.277 s"3) El) www.elementconsults.com Project#-37Degrees 011221 ENVIRONMENTAL nVC LEAD ASBESTOS HAZ id)A2/ O2-021 ASPEN BUILDING DEPARTMENT