HomeMy WebLinkAboutFile Documents.675 E Durant Ave.0037-2022-BCOM (12) 111116 COMcheck Software Version 4.1.5.5
A(1 Interior Lighting Compliance Certificate
Project Information
Energy Code: 2015 IECC
Project Title: The Little Nell Spa&Gym
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
675 East Durant Ave Robert Singer&Associates
Aspen, CO 81611 655 E.Valley Road
Basalt, CO 81621
970-963-5692
info@rsa-light.corn
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B X C)
1-Lobbies(Common Space Types:Lobby-General) 439 0.90 395
Allowance:Decorative Appearance/Fix. ID:01/012;01/008 144(a) 1.00 144(b)
Allowance:Decorative Appearance/Fix. ID:02/008 54(a) 1.00 54(b)
2-Foyer/Pre-Function(Common Space Types:Conference/Meeting/Multipurpose) 353 1.23 434
Allowance:Decorative Appearance/Fix. ID:02/010;03/010 96(a) 1.00 96(b)
Allowance:Decorative Appearance/Fix. ID:02/009 240(a) 1.00 240(b)
11-Private Reception(Common Space Types:Conference/Meeting/Multipurpose) 690 1.23 849
Allowance:Decorative Appearance/Fix. ID:04/011;03/011 48(a) 1.00 48(b)
Allowance:Decorative Appearance/Fix. ID: D1.001;07/011 384(a) 1.00 384(b)
Allowance:Decorative Appearance/Fix. ID:06/011 32(a) 1.00 32(b)
Allowance:Decorative Appearance/Fix. ID: 10/011 24(a) 1.00 24(b)
Allowance:Decorative Appearance/Fix. ID:05/011 50(a) 1.00 50(b)
Allowance:Decorative Appearance/Fix. ID: 12/011 48(a) 1.00 48(b)
Allowance:Decorative Appearance/Fix. ID:02/011 a 48(a) 1.00 48(b)
3-Gym(Gymnasium/Fitness Center:Exercise Area) 1235 0.72 889
Allowance:Decorative Appearance/Fix. ID:01/016;02/016 144(a) 1.00 144(b)
Allowance:Decorative Appearance/Fix. ID:04/016 96(a) 1.00 96(b)
Allowance:Decorative Appearance/Fix. ID: D1.006; D1.011; D1.016 576(a) 1.00 576(b)
Allowance:Decorative Appearance/Fix. ID: D1.006; D1.011; D1.016 120(a) 1.00 120(b)
4-Reception(Retail:Sales Area) 228 1.59 363
Allowance:Decorative Appearance/Fix. ID:04/014 8(a) 1.00 8(b)
Allowance:Decorative Appearance/Fix. ID: 10/014 144(a) 1.00 144(b)
Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:02/014;03/014 28(a) 1.40 39(b)
Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:06/014;07/014; 200(a) 1.40 240(b)
08/014
5-Restrooms(Common Space Types:Restrooms) 373 0.98 366
Allowance:Decorative Appearance/Fix. ID:03/001;03/003 40(a) 1.00 36(b)
Allowance:Decorative Appearance/Fix. ID:04/001;04/003 100(a) 1.00 96(b)
Allowance:Decorative Appearance/Fix. ID:05/001 48(a) 1.00 48(b)
Allowance:Decorative Appearance/Fix. ID:Water Closets 120(a) 1.00 120(b)
6-Electrical Room(Common Space Types:Electrical/Mechanical) 49 0.95 47
7-Storage Rooms(Common Space Types:Storage<50 sq.ft.) 139 1.24 172
8-Massage Treatment Rooms(Healthcare Facility:Exam/Treatment) 660 1.66 1096
Allowance:Decorative Appearance/Fix. ID:02/031;02/026;02/021 480(a) 1.00 4 0
lft)
Project Title: The Little Nell Spa &Gym Report`dat :- . 8/25
Data filename: \\192.168.25.2\data\PROJECTS\Bill Poss\Little Nell Spa &Gym\CONTROL\COMcheck\22-0825 TL Rage -1 f„o7
V 1LL22
COMcheck.cck �L
o4
"° ASPEN
,.mo BUILDING DEPARTMENT
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B X C)
10-Private Bathrooms(Common Space Types:Restrooms) 575 0.98 564
Allowance:Decorative Appearance/Fix. ID:02/033;02/028;02/024;02/020A 192(a) 1.00 192(b)
Allowance:Decorative Appearance/Fix. ID: D1.021; D1.026 288(a) 1.00 288(b)
Allowance:Decorative Appearance/Fix. ID:02/032;02/027;02/022;02/019 72(a) 1.00 72(b)
9-Hall/Corridor(Common Space Types:Corridor/Transition<8 ft wide) 84 0.66 55
Supplemental Allowed Watts(null)= 21
Total Allowed Watts= 9117
(a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s)are specified.
(b)Allowance is(B x C)or the actual wattage of the fixtures given in Proposed Power section,whichever is less.
(c)Supplemental watts must be associated with retail merchandise highlighting fixtures.
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Lobbies (Common Space Types:Lobby-General 439 sq.ft.)
'BW'Downlight:01/012;01/008:Art Downlights:Other: 1 12 12 144
'ID1'Decorative Picture Light:02/008:Decorative Art Picture Lights:Other: 1 6 9 54
'BW'Downlight:01/007:General Downlights:Other: 1 4 12 48
'B'Downlight:02/007:General Downlights:Other: 1 3 12 36
48W Power Supply:03/008:R5 Linear:Other: 1 6 48 288
Foyer/Pre-Function (Common Space Types:Conference/Meeting/Multipurpose 353 sq.ft.)
'B'Downlight:01/009;01/010:General Downlights:Other: 1 11 12 132
'B'Downlight:02/010;03/010:Art Downlights:Other: 1 8 12 96
48W Power Supply:02/009:R6 Linear:Other: 1 5 48 240
'TV/'TA'Linear Track&Insert:03/009:T1/TA Track:Other: 1 5 48 240
Private Reception (Common Space Types:Conference/Meeting/Multipurpose 690 sq.ft.)
'B'Downlight:01/011a;01/011:General Downlights:Other: 1 6 12 72
'B'Downlight:08/011;09/011: Bar Downlights:Other: 1 7 12 84
'B'Downlight:04/011;03/011:Art Downlights:Other: 1 4 12 48
'B'Downlight:02/011:Billiards Downlights:Other: 1 4 12 48
48W Power Supply: D1.001;07/011:RC&R5 Linear:Other: 1 8 48 384
'ID6'Decorative Pendant:06/011:Decorative Pendants:Other: 1 4 8 32
'ID7'Decorative Pendant: 10/011:Decorative Pendants:Other: 1 3 8 24
'ID11'Decorative Pendant:05/011: Decorative Pendant:Other: 1 1 50 50
96W Power Supply: 13/011:R5 Bar Linear:Other: 1 1 96 96
48W Power Supply: 12/011:R2 Linear:Other: 1 1 48 48
'T1'/'TA'Linear Track&Insert:03/011a:T1/TA Track:Other: 1 3 96 288
'B'Downlight:02/011a:Art Downlights:Other: 1 4 12 48
48W Power Supply: 11/011:R2 Linear:Other: 1 1 48 48
96W Power Supply: 14/011:R6 Bar Linear:Other: 1 1 96 96
Gym (Gymnasium/Fitness Center:Exercise Area 1235 sq.ft.)
'BW'Downlight:01/016;02/016:Art/Column Downlights:Other: 1 12 12 144
96W Power Supply:04/016:R6 Linear:Other: 1 1 96 96
96W Power Supply:03/016;01/017: R6H Linear:Other: 1 14 96 1344
48W Power Supply:03/016;01/017: R6H Linear:Other: 1 1 48 48
96W Power Supply: D1.006; D1.011; D1.016: RP*Panels:Other: 1 6 96 576
30W Power Supply: D1.006; D1.011; D1.016: RP*Panels:Other: 1 4 30 120
Reception ( Retail:Sales Area 228 sq.ft.)
'B'Downlight:01/014:General Downlights:Other: 1 4 12 48
'ID9'Decorative Pendant:04/014:Decorative Pendant:Other: 1 1 8 8
48W Power Supply: 10/014:R5 Linear:Other: 1 3 48 144
'B'Downlight:02/014;03/014: Merchandise Downlights:Other: 1 5 12 60
Project Title: The Little Nell Spa &Gym RepoPt'Zx'at 0 Et
Data filename: \\192.168.25.2\data\PROJECTS\Bill Poss\Little Nell Spa &Gym\CONTROL\COMcheck\22-0825 TLI Ra§e 1i 9�20722
COMcheck.cck VV
ii EVOIME
3 DI
"°.mo ASPEN
, BUILDING DEPARTMENT
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
48W Power Supply:06/014;07/014;08/014: R6 Linear:Other: 1 5 48 240
96W Power Supply:09/014:R7 Linear:Other: 1 1 96 96
48W Power Supply:05/014:R5 Linear:Other: 1 3 48 144
Restrooms (Common Space Types:Restrooms 373 sq.ft.)
'B'Downlight:01/001;01/003;Water Closets:General Downlights:Other: 1 14 12 168
'BW'Downlight:02/001;02/003:Sink Downlights:Other: 1 4 12 48
'ID8'Decorative Sconce:03/001;03/003: Decorative Sconces:Other: 1 8 4 36
48W Power Supply:04/001;04/003: R6 Linear:Other: 1 2 48 96
48W Power Supply:05/001:R8 Linear:Other: 1 1 48 48
30W Power Supply:Water Closets: R2S Linear:Other: 1 4 30 120
Electrical Room (Common Space Types:Electrical/Mechanical 49 sq.ft.)
'L4'Utility Light:01/036:Surface Mount:Other: 1 2 23 46
48W Power Supply:02/036:RK Linear:Other: 1 1 48 48
Storage Rooms(Common Space Types:Storage<50 sq.ft. 139 sq.ft.)
'E'Utility Light:Storage Rooms:Surface Mount:Other: 1 2 20 40
Massage Treatment Rooms( Healthcare Facility:Exam/Treatment 660 sq.ft.)
48W Power Supply:03/031;03/026;03/021: R6 Linear:Other: 1 3 48 144
96W Power Supply:01/031;01/026;01/021: R6 Linear:Other: 1 9 96 864
96W Power Supply:02/031;02/026;02/021: R2 Linear:Other: 1 5 96 480
Private Bathrooms (Common Space Types:Restrooms 575 sq.ft.)
'B'Downlight:01/019;01/032;01/027;01/022:General Downlights:Other: 1 10 12 120
'B'Downlight:01/033;01/028;01/024;01/020A:WC Downlights:Other: 1 4 12 48
'C'Downlight:01/020B;01/034;01/029;01/025:Shower Downlights:Other: 1 7 12 84
'C'Downlight:01/030;01/023:Sauna Downlights:Other: 1 3 12 36
48W Power Supply:02/033;02/028;02/024;02/020A: R2W WC Linear:Other: 1 4 48 192
48W Power Supply:02/034;02/029;02/025;02/020B: R2W Shower Linear:Other: 1 6 48 288
96W Power Supply: D1.021; D1.026: RT Sauna Linear:Other: 1 3 96 288
'ID10'Decorative Sconce:02/032;02/027;02/022;02/019:Decorative Sconces:Other: 1 8 9 72
Hall/Corridor(Common Space Types:Corridor/Transition <8 ft wide 84 sq.ft.)
'B'Downlight:01/018:General Downlights:Other: 1 4 12 48
Total Proposed Watts= 9026
Interior Lighting PASSES
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Name-Title Signature Date
r,,
Project Title: The Little Nell Spa &Gym RepoPt'Zx'at Et
Data filename: \\192.168.25.2\data\PROJECTS\Bill Poss\Little Nell Spa &Gym\CONTROL\COMcheck\22-0825 TLI VVRase 1L 9k0722
COMcheck.cck
iiEWlliEDI
"° ASPEN
BUILDING DEPARTMENT
COMcheck Software Version 4.1.5.5
Inspection Checklist
Energy Code: 2015 IECC
rA
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 Plans, specifications, and/or EComplies Requirement will be met.
[PR4]1 calculations provide all information Does Not
with which compliance can be
determined for the interior lighting ❑Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) r EIVF D
Project Title: The Little Nell Spa &Gym Repo te: /
Data filename: \\192.168.25.2\data\PROJECTS\Bill Poss\Little Nell Spa &Gym\CONTROL\COMcheck\22-0825 TL 6a§e 1, L
¢ f„0722
COMcheck.cck L�
-0.,EVOleeafi
ASPEN
BUILDING DEPARTMENT
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID 1
C405.2.1 Lighting controls installed to uniformly ❑Complies Requirement will be met.
[EL15]1 I reduce the lighting load by at least ❑Does Not
50%. [Not Observable
I ❑Not Applicable
C405.2.1 I Occupancy sensors installed in ❑Complies Requirement will be met.
[EL18]1 I required spaces. ❑Does Not
[Not Observable I
❑Not Applicable
C405.2.1, Independent lighting controls installed ❑Complies Requirement will be met.
C405.2.2. per approved lighting plans and all ❑Does Not
3 manual controls readily accessible and ❑Not Observable
[EL23]2 visible to occupants.
❑Not Applicable
C405.2.2. Automatic controls to shut off all ;❑Complies Requirement will be met.
1 building lighting installed in all ❑Does Not
[EL22]2 buildings. ❑Not Observable
❑Not Applicable
01 .3 Daylight zones provided with ;❑Complies Exception: Requirement does not apply.
individual controls that control the ❑Does Not
lights independent of general area
lighting. ❑Not Observable
❑Not Applicable
C405.2.3, Primary sidelighted areas are Complies Exception: Requirement does not apply.
C405.2.3. equipped with required lighting ❑Does Not
1, controls.
C405.2.3. ❑Not Observable,
2 ❑Not Applicable
[EL2O]1
C405.2.3, Enclosed spaces with daylight area ;❑Complies Exception: Requirement does not apply.
C405.2.3. under skylights and rooftop monitors ❑Does Not
1, are equipped with required lighting
C405.2.3. controls. Not Observable
3 ❑Not Applicable
[EL21]1
C405.2.4 �Separate lighting control devices for EComplies Requirement will be met.
[EL4]1 specific uses installed per approved Does Not
lighting plans.
ENot Observable
❑Not Applicable 1
C405.2.4 Additional interior lighting power ❑Complies Requirement will be met.
[EL8]1 allowed for special functions per the ❑Does Not
approved lighting plans and is
automatically controlled and ['Not Observable
separated from general lighting. ❑Not Applicable
i
C405.3 Exit signs do not exceed 5 watts per ❑Complies Requirement will be met.
[EL6]1 face. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
(High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Ripri'FARTD
Project Title: The Little Nell Spa &Gym Report date: 08/25/2
Data filename: \\192.168.25.2\data\PROJECTS\Bill Poss\Little Nell Spa &Gym\CONTROL\COMcheck\22-0825 TLI 68§e 1 L,5 f20722
COMcheck.cck /
it 03/31,023 pi, ASPEN
BUILDING DEPARTMENT
Section
# Final Inspection Complies? Comments/Assumptions
& Req.ID
C303.3, ;Furnished O&M instructions for ❑Complies Requirement will be met.
C408.2.5. systems and equipment to the ❑Does Not
2 building owner or designated
[F117]3 representative. [Not Observable
❑Not Applicable
C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values.
[F118]1 lighting power is consistent with what ❑Does Not
is shown on the approved lighting
plans, demonstrating proposed watts ['Not Observable
are less than or equal to allowed ❑Not Applicable
watts.
C408.2.5. :Furnished as-built drawings for ❑Complies Requirement will be met.
1 electric power systems within 90 days ❑Does Not
[F116]3 of system acceptance.
[Not Observable
ENot Applicable
C408.3 1Lighting systems have been tested to ❑Complies Requirement will be met.
[F133]1 ensure proper calibration, adjustment, ❑Does Not
programming, and operation. [Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Ripri'FARTD
Project Title: The Little Nell Spa &Gym Report date: 08/25/2
Data filename: \\192.168.25.2\data\PROJECTS\Bill Poss\Little Nell Spa &Gym\CONTROL\COMcheck\22-0825 TLI oae 1,6 9f20722
COMcheck.cck
o1aDit 2023
ASPEN
BUILDING DEPARTMENT
rf
Project Title: The Little Nell Spa &Gym Rent QS/IVf D
Data filename: \\192.168.25.2\data\PROJECTS\Bill Poss\Little Nell Spa &Gym\CONTROL\COMcheck\22-0825 TL V Rae 1i9f„0722
COMcheck.cck / L
= a ASPEN
BUILDING DEPARTMENT