Loading...
HomeMy WebLinkAboutFile Documents.675 E Durant Ave.0037-2022-BCOM (13) Little Nell Spa & Gym PERMIT/ PRICING SET: 6/1/2022 f`A Type Image Product/Manufacturer Attributes Notes Lighting Control DIN.Panel Lutron Catalog #: Refer to Lutron BOM "Lutron Control System" Description: HomeWorks QSX DIN Rail Panel with Breakers EC to verify power feed phase and breakers. DMX. Lutron Catalog #: Refer to Lutron BOM "Lutron Control System" Description: HomeWorks DMX Processor Keypad Lutron Catalog #: RSDB-**-**-E-CPN7435; RSD-**-**- YP "Lutron Control System" CPN7435 Description: HomeWorks QSX Keypad with White LEDs Lutron Catalog #: Refer to Lutron BOM LV.Panel 1 '° "Lutron Control System" Description: Homeworks Low Voltage Enclosures 1 RECEIVED L Rid 08/18/2022 3 RSA 03/331/2 023 J .MP ASPEN BUILDING DEPARTMENT Type Image Product/ Manufacturer Attributes Notes OS.Ceilin Lutron Catalog #: Refer to Lutron BOM 9 "Lutron Control System" Description: Homeworks Wireless Vacancy Sensor Exact placement to be coordinated with room layout and interiors. OS.WaII Lutron Catalog #: MS-B102 "Sensor" 1 Description: J Occupancy/Vacancy Switch Contractor to verify that switch is compatible with load. Lutron Catalog #: HQP7-2 Processor '- 'T ' ! "Lutron Control System" Description: HomeWorks QSX Processor Lutron Catalog #: Refer to Lutron BOM Repeater —___, "Lutron Control System" Description: Homeworks Hybrid Repeater Total Protection Solutions Catalog #: TK-TTLP-1S240-FL(Breaker Panels) TPS ,_r "Lutron Control System" Description: Surge Protection Lutron system to be protected by complete home lighting/surge protection system. See attached a notes. For additional solutions see Lutron's notes. RECEIVED e 6lf .Q 08/18/2022 ALL INFORMATION TO BE VERIFIED AND CONFIRMED PRIOR TO ORDER. /31/2023 J RSA CONTACT TECHNOLOGY BY DESIGN FOR FACTORY DIRECT PRICING: 855-963-1200 : info@tbd-inc.com :wwv i 'mP ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 DIN.Panel Catalog #: Refer to Lutron BOM Page 1 of 3 MEW RKSQS � product specifications 3691106c 02.04.19 120 V-'- DIN Breaker Panels The Lutron DIN rail panels with integrated arc-fault circuit breakers are designed to accept Lutron DIN power modules(DPMs).The compatible I 0 s[ DPMs can be configured in the panel to control multiple load types to fit the 1 size, lighting plan,and design of a project. DIN panels with breakers reduce the number of wiring connections required when compared to a similar feed through panel. Panels may either be surface-mounted or recess-mounted in an electrical closet or other equipment room. Features 1� •Panels come ready to install up to 8 DIN power modules ma ° •Panels can house these DPMs: —LQSE-2ECO-D —LQSE-4A1-D III b a e � i u i —LQSE-4A-120-D —LQSE-4T5-120-D —LQSE-4S8-120-D —LQSE-4M-120-D U_L• • Includes 8 AFCI breakers factory installed and wired to terminals for each ' _- module row. 15 A and 20 A versions are available I 0 •Panels come with a QS wire landing board(QS-WLB)and QS link wiring 11 E ° I ®! harness for easy installation •Panels include 4 empty breaker positions to power additional general branch �;' ° ° circuits. Breakers are not included.Only use Square D,QO series stab-in }' • breakers li01* •Extensively tested to ensure optimal thermal performance with maximum load in 32°F to 104°F(0°C to 40°C)ambient environment •Rated for 120 applications ��nnn�iwiio^uc„ PD8-65A-120L4-xx shown ra Customer Assistance: RE r E IVE D 1.844.LUTRONI (U.S.A./Canad www.lutron.com/support 1 +1.888.235.2910(Mexico) 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: g49■ ISSUE DATE: 06/01/2022 DIN.Panel Catalog #: Refer to Lutron BOM Page 2 of 3 MEW RKSQS � product specifications 3691106c 02.04.19 120 V-s- DIN Breaker Panels Specifications Model Numbers Single phase 3-wire: 120/240 V - 50/60 Hz 125 A Main input &Power PD8-65A-120L3-15-single phase,3-wire panel with 15 A branch circuit breakers PD8-65A-120L3-20-single phase,3-wire panel with 20 A branch circuit breakers Three phase 4-wire: 120/208 V— 50/60 Hz 125 A Main input PD8-65A-120L4-15-Three phase,4-wire panel with 15 A branch circuit breakers PD8-65A-120L4-20-Three phase,4-wire panel with 20 A branch circuit breakers Capacity* Up to Eight DPMs and one QS-WLB Regulatory Approvals Complies with UL 508;Complies with NOM-003 Environment Ambient operating temperature:32°F to 104°F(0°C to 40°C),0 to 90%humidity, non-condensing.Indoor use only. Cooling Passive cooling Line-Voltage Connections Use copper wire only.Supply conductors should be rated 60°C to 75°C. DIN rail mounted terminal blocks provide convenient connections for field wiring -Main feed terminals accept 6 AWG to 2/0 AWG(16 mm2 to 70 mm2)wire -Load wiring terminal blocks accept one 14 AWG to 10 AWG(2.5 mm2 to 4.0 mm2)wire Breaker Ratings Details for the 8 included breakers are as follows: Manufacturer:Square D Models: 15 A Q0115CAFI,20 A Q0120CAFI Type: Plug-in mount,combination Arc-fault Breaking Capacity:10 kA at 120 Vim,10 kA at 120/240 V'— Dimming Capability: Capable of up to 1920 W of dimming load without nuisance tripping. Breaker rating&local code may reduce the permissible loading. Module Bypass All terminal blocks are shipped with a bypass jumper installed. After verifying each circuit is wired correctly and the modules are installed,remove the bypass jumpers from the H and DH terminals for system operation Ground Bar Terminals 27-position ground bar.1 ground lug accepts 6 AWG to 2/0 AWG(16 mm2 to 70 mm2)wire Dimensions Panel:15.125 in x 64.5 in x 3.94 in(385 mm x 1638 mm x 100 mm) Cover:15.875 in x 65.0 in x 0.06 in(403 mm x 1651 mm x 1.5 mm) Mounting Install and wire in accordance with all local and national codes.Panel may be surface-mounted or recess-mounted.Panel fits between standard 16 in(407 mm)on-center stud framing.Panel must be mounted within+/-7°of vertical.Mount the panel so that line-voltage wiring will be at least 6 ft(1.8 m)from audio or electronic equipment and wiring.Mounting hardware is not provided.Mount panel using one of the following methods: Surface-Mount:Use keyholes with bolts sufficient for 110 lb(50 kg)load,1/4 in(M6)bolts recommended. Recess-Mount:Use hardware sufficient for 110 lb(50 kg)through the corners of the panel. Panel is 3.94 in(100 mm)deep past cover mounting tabs(including pedestal). NOTICE:Breaker panels are required to be installed to provide sufficient access and working space according to the National Electric Code(NEC®).A typical installation may require 3 ft to 4 PG ft(0.914m to 1.22m)in front of the panel and 30 in(772 mm)width to provide sufficient space for panel access. NOTICE:This equipment is air-cooled.Allow at least 12 in(305 mm)of air space at the top, bottom,and front of the cover or as required by local codes(whichever is greater). NOTICE:Power supply will hum slightly and internal relays will click while in use.Mount in a location where such noise is acceptable. NOTICE:Do not vertically stack panels. Construction Panel:16-gauge galvanized sheet metal(unpainted) Cover:Coated metal cover(black)with ventilation holes.Cover is attached using phillips-head screws(included) Warranty www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf Use of non-Lutron equipment in the panel voids the warranty. Customer Assistance: RE EIVED 1.844.LUTRONI (U.S.A./Canad wwW.lutron.com/support 2 +1.888.235.2910(Mexico) 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 DIN.Panel Catalog #: Refer to Lutron BOM Page 3 of 3 MEW RKSQS product specifications 3691106c 02.04.19 120 V-N- DIN Breaker Panels Dimensions and Mounting Dimensions are shown as: in(mm) 3690306) Up PD8-65A-120Lx-xx 14.375 J0oo00000: ooc00000 1.935 15.125 Mount (45) (384) vanel vertically 15.875 10.256 (403) A F (261)X. 4 + 1 11 11 oo®o I`°fie A / ® \ 1.766(45) L ° L 8 R00000000a ° 0000000000 'Do 0.3125(8) o 00 + diameter::::::::� 0 O0 0 0 oo .l..-- ---+ 0.625(16) oo diameter • aeeeeoff . o . . 0 0 IIi -wveee°e�.00 47.88 aaaaaaa 0o I . (1216) o o 111.•ov000001' 65.0 00 64.5 Ill, i 000000 0 aaaaaaa (1651) o (1638) n • • 1 0 O M-w00000 '1' 00 1 AA 0000000 00 Ili p. o 00 o dmm0000m Surface-mount 0000000 0o with keyholes 0 o 0.------- I— (4x) 00 ki 000000E I oo o • 00 j {ll� ® ®1 = ara CI , 0 m,.= 14.854 0 • -81 '<= (377) a � �n=.i-oi�o�s°loa • EEaaaaaaaa S ° i li i iaaa i Q. 0 Ea00000000 .. `� ° Recess 11.256�� 0.375 mount with (286) (10) Screws(4x) 0000 O o00000 f Lutron and HomeWorks are trademarks of Lutron Electronics Co.,Inc.,registered in the U.S.and other countries. Customer Assistance: 1.844.LUTRON1 (U.S.A./CanadRErEIV "' www.lutron.com/support 3 +1.888.235.2910(Mexico) 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: DMX.Pro ISSUE DATE: 06/01/2022 cessor Catalog #: Refer to Lutron BOM Page 1 of 8 QS System QSE-CI-DMX Control Interfaces 369372e 1 02.05.18 QSE-CI-DMX Control Interface Description . The QSE-CI-DMX operates either in a standalone QS <` 111- system or a Quantum system. It performs different F `c'•'Qs QS ;c1e. functions depending on the system in which it is operating. QS Standalone System Atib The QSE-CI-DMX control interface allows zones on a .;�,� GRAFIK Eye QS to control DMX512-controlled devices. Any zone on the GRAFIK Eye QS can be mapped to either a single DMX512 channel or to three separate DMX512 channels,for RGB/CMY color-control applications. Quantum System The DMX channels(maximum of 32)are mapped to Quantum zones,and can be programmed as 1-channel lighting, 1-channel integration,or 3-channel RGB/CMY. If the QSE-CI-DMX is part of a Quantum system,GRAFIK Eye QS zones cannot be programmed to control DMX channels. Features • Map any zone on a GRAFIK Eye QS control unit or any Quantum zone to any single DMX512 channel • Map any zone on a GRAFIK Eye QS control unit or any Quantum zone simultaneously to three DMX512 channels for RGB/CMY color-control • Integral RGB/CMY lookup table that maps GRAFIK Eye QS zone intensities or Quantum zone intensities to RGB/ CMY values(colors) • RGB/CMY table can be customized by using the Lutron QS Color Configuration Tool(PC application available on the CD packaged with the QSE-CI-DMX,and at www.lutron.com/qs),or within the Quantum Q-Design software pa OWTRON SPECIFICATION SUBMITTAL Page 1 Job Name: Model Numbers: R CEIVED Job Number: 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: DMX.Pro gw94■ ISSUE DATE: 06/01/2022 cessor Catalog #: Refer to Lutron BOM Page 2 of 8 QS System QSE-CI-DMX Control Interfaces 369372e 2 02.05.18 Specifications Regulatory Approvals Limitations • RoHS Compliant • In a Quantum system,only 32 DMX channels can be programmed per device.The 32 channels can be any Power Requirements of the 512 available addresses,so DMX combiners • Low-voltage SELV/PELV/NEC®Class 2 can be used if more than 32 DMX channels need to be • Operating Voltage:24-36 V— 65 mA controlled from a single DMX universe. • Daylighting is not supported for DMX loads. Environment • Loadshedding is not supported for DMX loads. • 32°F to 104°F(0°C to 40°C). • Nightlighting is not supported for DMX loads. • Relative humidity less than 90%non-condensing. • 1-channel lighting can be raised/lowered, but • Unit generates heat,maximum 8 BTU/hr. 1-channel integration and RGB can not. Note: In a stand-alone system, raise/lower cycles System Capabilities/Limits through the RGB color table. QS Link System Limits(for units controlled by a Requirements GRAFIK Eye QS control unit) • 100 QS devices per QS link. The QSE-CI-DMX requires the following: • 100 zones per QS link. •At least one GRAFIK Eye QS control unit connected to the QSE-CI-DMX through the QS communication link, QS Link System Limits(for units controlled by a or Quantum system) A Quantum system • 99 QS devices per QS link. •QS Link power supply;either: • 512 switch legs per link(each DMX channel=1 switch leg). -GRAFIK Eye QS control unit,as long as the GRAFIK • 32 DMX channels per QSE-CI-DMX control interface. Eye QS control unit is NOT powering any other QS QS Link Wiring Limits link devices drawing a total of two(2)or more power draw units •Total length of link must not exceed 2000 ft(610 m). • Do not allow SELV/PELV/NEC®Class 2 wires to -QS Link power supply,such as the ASPS P1 1 50 or contact line/mains wires. A Quantum Light Management Hub DMX512 Link System Limits Note:The QSE-CI-DMX consumes 2 power draw units • Consult your DMX equipment installer. on the QS link;see the SELV/PELV/NEC®Class 2 QS Link Requirements and Wiring section for more DMX512 Link Wiring Limits information • Each terminal can accept up to two 18 AWG(1.0 mm2) • DMX512 link terminators at both ends of the DMX512 wires. link(available from Lutron,part number LT-1) • Link must be 1000 ft(305 m)or less. •QS Communication Link Wire(SELV/PELV/NEC® • DMX Link must begin and end with link terminators Class 2).See the Wire Sizes table. (available from Lutron;part number LT-1). •Three pins on the DMX connector for connecting the QSE-CI-DMX to DMX512-controlled equipment. (r�� IARluiooi OWTRON SPECIFICATION SUBMITTAL Page 2 Job Name: Model Numbers: i Job Number: R C E IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: DMX.Pro gw94■ ISSUE DATE: 06/01/2022 cessor Catalog #: Refer to Lutron BOM Page 3 of 8 QS System QSE-CI-DMX Control Interfaces 369372e 3 02.05.18 Example Application The QSE-CI-DMX can be programmed so that any or all zones on a GRAFIK Eye QS control unit can control either 3 channels(e.g., RGB)or 1 channel(i.e., intensity of a single light). Raising or lowering a zone will change the color (for a 3-channel zone)or the intensity(for a 1-channel zone). If,for example,you have an RGB LED fixture and a single stage light,you can configure your settings so that: • Channels 3,4,and 5 correspond to the red,green,and blue channels on the RGB LED fixture • Channel 7 corresponds to the stage light You can then set up the GRAFIK Eye QS control unit so that: •Zone 3's intensity=desired RGB fixture color •Zone 6's intensity=desired stage light intensity When you select a pre-programmed scene on the GRAFIK Eye QS control unit: •The QSE-CI-DMX converts the zone intensities for that scene into DMX512 channel settings. •The RGB LED fixture will go to the color programmed for that scene,and the stage light will go to the desired intensity. GRAFIK Eye QS control unit QSE-CI-DMX o 00 SELV/PELV/NEC®Class 2 DMX output QS link wiring for system communication va OWTRON SPECIFICATION SUBMITTAL Page 3 Job Name: Model Numbers: i Job Number: R C E IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: DMX.Pro ■ ISSUE DATE: 06/01/2022 cessor Catalog #: Refer to Lutron BOM Page 4 of 8 QS System QSE-CI-DMX Control Interfaces 369372e 4 02.05.18 Dimensions Dimensions are in inches(mm) 2.5 Mounting holes (63) Terminal ;�. blocks �J LEDs and addressing on this side switches on this side 3.75 I (4.25 Mounting Hole Detail (95) i 0.1875 �, (5)dia. 0.3125 E� �I (9)dia. 0.1875(5) 5.25 dia. (134) 0.25 • (6) 1.0 #6 or#8(M3 or M4) (27) I screw recommended Mounting Options Mount where terminal blocks,switches,and LEDs Mounting Methods are accessible.Strip 3/8 in(10 mm)of insulation from wires. Each data link terminal will accept up O O to two 18 AWG(1.0 mm2)wires.Connect wiring as shown on the Wiring page. LED 1 is continuously lit(Power)and LED 7 blinks rapidly(Data Link RX) when the SELV/PELV/NEC®Class 2 Data Link is installed correctly.Choose from the following LUT-I9AV-1 U mounting methods: 1.Direct Wall Mounting Mount the control interface directly on a wall,as wall O shown in Mounting Methods at right, using screws I (not included).When mounting, provide sufficient space for connecting cables. control Interface Dr 0_1 2.Rack Mounting R, Place the unit in the LUT-19AV-1U AV rack using screws provided with the unit.The LUT-19AV-1U LUT-5x10-ENC will hold up to four units. 3.Enclosed Wall Mounting If conduit is desired for wiring, use the LUT-5x10-ENC to mount one unit. OWTRON SPECIFICATION SUBMITTAL Page 4 Job Name: Model Numbers: RCEIVED Job Number: 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: DMX.Pro ■ ISSUE DATE: 06/01/2022 cessor Catalog #: Refer to Lutron BOM Page 5 of 8 QS System QSE-CI-DMX Control Interfaces 369372e 5 02.05.18 SELV/PELV/NEC® Class 2 QS Link Requirements and Wiring • System communication uses SELV/PELV/NEC®Class 2 wiring. •Wiring can be daisy-chained or T-tapped(see below). •Wiring must be run separately from line/mains voltage. •Total length of control link must not exceed 2000 ft(610 m). •Connect the terminal 1,3,and 4 connections to all control units,wallstations,and control interfaces. See Powering the QSE-CI-DMX for pin 2 connectivity. •The QSE-CI-DMX consumes 2 Power Draw Units(PDUs)on the QS link. For more information,see Power Draw Units on the QS Link,PN 369405,at www.lutron.com/qs. Wire Sizes(check compatibility in your area) QS Link Wiring Length Wire Gauge Lutron Cable Part Number Less than 500 ft(153 m) Power(terminals 1 and 2) 1 pair 18 AWG(1.0 mm2) GRX-CBL-346S(non-plenum) Data(terminals 3 and 4) GRX-PCBL-346S(plenum) 1 twisted,shielded pair 22 AWG(0.5 mm2) 500 to 2000 ft Power(terminals 1 and 2) (153 to 610 m) 1 pair 12 AWG(4.0 mm2) GRX-CBL-46L(non-plenum) Data(terminals 3 and 4) GRX-PCBL-46L(plenum) 1 twisted,shielded pair 22 AWG(0.5 mm2) Daisy-Chain Wiring Example GRAFIK Eye QS control seeTouch QS unit wallstations QSE-CI-DMX Sivoia QS power panel T-Tap Wiring Example seeTouch QS GRAFIK Eye QS wallstations control unit ® ® ® a Sivoia QS _ power panel al 2 Sivoia QS Ra shade ® _ QSE-CI-DMX (powered separately) QSPS power supply OWTRON SPECIFICATION SUBMITTAL Page 5 Job Name: Model Numbers: R CEIVED Job Number: 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: DMX.Pro ■ ISSUE DATE: 06/01/2022 cessor Catalog #: Refer to Lutron BOM Page 6 of 8 QS System QSE-CI-DMX Control Interfaces 369372e 6 02.05.18 SELV/PELV/NEC® Class 2 Terminal Connections Wire Sizes(check compatibility in your area) QS Link Wiring Length Wire Gauge Lutron Cable Part Number Less than 500 ft(153 m) Power(terminals 1 and 2) 1 pair 18 AWG(1.0 mm2) GRX-CBL-346S(non-plenum) Data(terminals 3 and 4) GRX-PCBL-346S(plenum) 1 twisted,shielded pair 22 AWG(0.5 mm2) 500 to 2000 ft Power(terminals 1 and 2) (153 to 610 m) 1 pair 12 AWG(4.0 mm2) GRX-CBL-46L(non-plenum) Data(terminals 3 and 4) GRX-PCBL-46L(plenum) 1 twisted,shielded pair 22 AWG(0.5 mm2) Connect Drain/Shield as shown. Do not connect to Ground(Earth)or Wallstation/Control Interfaces. Connect the bare drain wires and cut off the outside shield. Data Link:(1)shielded,twisted pair 22 AWG(0.5 mm2) 4:MUX 3:MUX D:Drain/Shield Note:Do not connect Drain/Shield to Ground(Earth)or Wallstation/Control QSE-CI-DMX � (2)12 AWG Interfaces.Connect the bare drain / (4.0 mm2) wires and cut off the outside shield. Fit Note:12 AWG(2.5 mm2)conductors ! • for Common(terminal 1)and V+Power SELV/PEEN/NEC®(Class 2:USA) �I (terminal 2)will not fit in terminals;use 18 AWG(1.0 mm2)pigtails(<6 in[152 mm]). Power wiring: 1:Common (2)12 AWG 2:V+ (4.0 mm2) (2)18 AWG(1.0 mm2)pigtails, To DMX equipment 6 in(152 mm)maximum length GG ra OWTRON SPECIFICATION SUBMITTAL Page 6 Job Name: Model Numbers: — Job Number: RCEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: DMX.Pro ■ ISSUE DATE: 06/01/2022 cessor Catalog #: Refer to Lutron BOM Page 7 of 8 QS System QSE-CI-DMX Control Interfaces 369372e 7 02.05.18 Powering the QSE-CI-DMX • Power for one QSE-CI-DMX counts as two devices toward the maximum of three devices per GRAFIK Eye QS control unit when powered off of Pin 2 of the GRAFIK Eye QS. •Another option is to power the QSE-CI-DMX from a QS Link power supply(ASPS-P1-1-50,QSPS-P2-1-50,or QSPS-P3-1-50);a QS shade panel power supply(QSPS-P2-10-60 for 230 Vti,or QSPS-P1-10-60 for 120 V—);or a Quantum light management hub. Wiring Examples QSE-CI-DMX Powered by a GRAFIK Eye QS Control Unit DMX Lin QS Link Rear View of GRAFIK Eye QS control unit ®®®® n r-r reEl CID o O o O J O 0 o QS link: 1:Common (re 2:V+ 3: MUX 4: MUX QSE-CI-DMX Powered by a QSPS Power Supply GRAFIK Eye QS seeTouch QS control unit wallstations QSE-CI-DMX H ® (powered by QSPS)separately Y DMX Link ra QS Link Lutron Cable QSPS GRX-CBL-346S-500 power supply OWTRON SPECIFICATION SUBMITTAL Page 7 Job Name: Model Numbers: Job Number: R CEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: DMX.Pro ISSUE DATE: 06/01/2022 cessor Catalog #: Refer to Lutron BOM Page 8 of 8 QS System QSE-CI-DMX Control Interfaces 369372e 8 02.05.18 DMX512 Link Wiring Connect the DMX link terminals on the QSE-CI-DMX interface to input terminals on DMX512-controlled equipment. • Each terminal on the QSE-CI-DMX accepts two 18 AWG(1.0 mm2)wires. • Link must be 1000 ft(305 m)or less. • Link must begin and end with link terminators(available from Lutron; part number LT-1). Pin on QSE-CI-DMX Terminal Connection to DMX Equipment 1: DMX512 system COMMON DMX512 system COMMON Note: Do NOT connect to COMMON on GRAFIK Eye QS control unit or other Lutron equipment NC Not connected 3: DMX512 system DATA+ DMX512 system DATA+ 4: DMX512 system DATA- DMX512 system DATA- PO OLutron,Lutron,GRAFIK Eye,seeTouch,Sivoia,and Quantum are trademarks of Lutron Electronics Co.,Inc.,registered in the U.S.and other countries. Q-Design is a trademark of Lutron Electronics Co.,Inc. NEC is a registered trademark of National Fire Protection Association,Quincy,Massachusetts. OLUTRON SPECIFICATION SUBMITTAL Page 8 Job Name: Model Numbers: R CEIVED Job Number: 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: Keypad ■ 1r:I) ISSUE DATE: 06/01/2022 VI Catalog #: RSDB-**-**-E-CPN7435; RSD-**-**-CPN7435 Page 1 of 7 Ima r 5 a Hp EW RKS QS product specification CPN7435a 09.12.16 HomeWorks® QS Wired seeTouch® Architectural Keypads HomeWorks QS seeTouch keypads provide homeowners with a simple and elegant way to operate lights,shades/draperies,motorized screens,thermostats,and many other devices. • HomeWorks QS seeTouch keypads feature • large,easy-to-use buttons, plus a unique White backlit engraving option that makes the keypads readable any time of the day or night. • seeTouch buttons are rounded,allowing engraving to be displayed at an upward angle, increasing readability. Replacement Kits are available in a variety of colors and with custom engraving to clearly identify each button's function.The flexible HomeWorks QS wired seeTouch architectural design of the keypads allows the color, keypads are available in many button number of buttons,and button configuration configurations,shown on the following page. to be changed by installing a new engraved Replacement Kit. All HomeWorks QS wired seeTouch models have two contact closure inputs on the back of the unit which provide independent functions from the front buttons.Other options include configurations with infr red receiver and raise/ lower buttons. Use Lutron®Nova T*®wallplates.Wallplates are included with the keypad.Lutron Nova T* wallplates snap on with no visible means of attachment. ki, pa 1 1 Lutron® www.lutron.com 24/7 Technical Support 800.523.9466 RE( EI /ED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: Keypad 5/1 . fy ISSUE DATE: 06/01/2022 Catalog #: RSDB-**-**-E-CPN7435; RSD-**-**-CPN7435 Page 2 of 7 () r " H�MEW RKS.QS product specification CPN7435a 09.12.16 HomeWorks® QS Wired seeTouch® Architectural Keypads Non-Insert Style Architectural Keypads Model Numbers RSD-W1 BN-XX*-CPN7435 1 Button Keypad RSDB-W1 BN-XX*-E-CPN7435 Engraved Replacement Kt I j RSD-W2BSN-XX*-CPN7435 2 Button Keypad 0 . a RSDB-W2BSN-XX*-E CPN7435 Engraved Replacement Kit a 0 RSD-W3BSN-XX*-CPN7435 3 Button Keypad EDRSDB-W3BSN-XX*-E-CPN7435 Engraved Replacement Kt RSD-W3BSRLN-XX*-CPN7435 3 Button with Raise/Lower W18N W2BSN W3BSN W3BSRLN Keypad RSDB-W3BSRLN-XX*-E-CPN7435 Engraved Replacement Kit RSD-W4BSN-XX*-CPN7435 4 Button Keypad RSDB-W4BSN-XX*-E-CPN7435 Engraved Replacement Kt 0 RSD-W4SN-XX*-CPN7435 4 Scene with Raise/Lower I 1 Keypad l RSDB-W4SN-XX*-E-CPN7435 Engraved Replacement Kt I I I RSD-W5BN-XX*-CPN7435 5 Button Keypad — RSDB-W5BN-XX*-E-CPN7435 Engraved Replacement Kt W4BSN W4SN W5BN W5BRLN RSD-W5BRLN-XX*-CPN7435 5 Button with Raise/Lower Keypad RSDB-W5BRLN-XX*-E-CPN7435 Engraved Replacement Kt RSD-W5BILN-XX*-CPN7435 5 Button with Raise/Lower Keypad and Infrared Receiver RSDB-W5BIRNXX*-E-CPN7435 Engraved Replacement Kt I I I I-- RSD-W6BN-XX*-CPN7435 6 Button Keypad RSDB-W6BN-XX*-E-CPN7435 Engraved Replacement Kt W5BIRN W6BN W6BRLN W7BN RSD-W6BRLN-XX*-CPN7435 6 Button with Raise/Lower Keypad RSDB-W6BRLN-XX*-E-CPN7435 Engraved Replacement Kt • • RSD-W7BN-XX*-CPN7435 7 Button Keypad O RSDB-W7BN-XX*-E-CPN7435 Engraved Replacement Kt I 0 RSD-W1 RLDN-XX*-E-CPN7435 Engraved Replacement Kit RSDB-W1 RLDN-XX*-CPN7435 Dud Group with Raise/Lower Keypad kil RSD-W2RLDN-XX*-CPN7435 Dual Group with Dual Raise/ WIRLDN W2RLDN W3BDN W2BRLN Lower Keypad " '" ICI RSDB-W2RLDN-XX*-E-CPN7435 Engraved Replacement Kit RSD-W3BDN-XX*-CPN7435 Dud Group Keypad RSDB-W3BDN-XX*-E-CPN7435 Engraved Replacement Kt RSD-W2BRLN-XX*-CPN7435 2 Button with Raise/Lower Keypad I I I RSDB-W2BRLN-XX*-E-CPN7435 Engraved Replacement Kit RSD-W4BRLN-XX*-CPN7435 4 Button with Raise/Lower Keypad WSBRLN RSDB-W4BRLN-XX*-E-CPN7435 Engraved Replacement Kit *"XX"in the model number represents color/finish code.Se colors and finishes at end of document. 2 i Lutron® www.lutron.com 24/7 Technical Support 800.523.9466 RE( EI\/ED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: Keypad ■ fy 491ISSUE DATE: 06/01/2022 Catalog #: RSDB-**-**-E-CPN7435; RSD-**-**-CPN7435 Page 3 of 7 r 5 a H�O EW RKS QS product specification CPN7435a 09.12.16 HomeWorks® QS Wired seeTouch® Architectural Keypads Specifications Model Numbers See pages 2 and 3 for complete lists of model numbers. Power 24 V== 30 mA IEC PELV/NEC®Class 2 Typical Power 0.6 W; 1 Power Draw Unit(PDU) Consumption Test conditions:all backlights on medium intensity,two LEDs on(two presets active), keypad powered at 24 V Regulatory Approvals UL,cUL, NOM, FCC, IC,COFETEL Environment Ambient operating temperature:32°F to 104°F(0°C to 40°C), 0%to 90%humidity, non-condensing. Indoor use only. Communications Connects to QS wired device link on Homeworks QS processor. ESD Protection Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2. Surge Protection Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits. Power Failure Power failure memory:should power be interrupted,the keypad will return to its previous state when power is restored. Mounting U.S.wallbox 31/2 in(89 mm)deep, 21/4 in(57 mm)deep minimum,or low-voltage mounting bracket Wiring Control wire must be 1 pair 18 AWG(1.0 mm2) IEC PELV/NEC®Class 2 for power and 1 pair 22 to 18 AWG (0.5 to 1.0 mm2)IEC PELV/NEC®Class 2 twisted/shielded for data (see Wiring). Warranty 8 Year Limited Warranty. http://www.lutron.com/resiinfo Design Features • White status&backlit LEDs. • Use Lutron®Nova T*®wallplates.Wallplates • Backlit button/engraving. are included with the keypad. • Field-changeable Replacement Kits make for • Lutron Nova T* wallplates snap on with no easy customization. visible means of attachment. 1 • All terminal block inputs are over-voltage and • Use Replacement Kits to change color,button miswire-protected against wire reversals and configuration,or engraving pa shorts. 41 Lutron® www.lutron.com 24/7Technical Support 800.523.9466 RECEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: Keypad ISSUE DATE: 06/01/2022 Catalog #: RSDB-**-**-E-CPN7435; RSD-**-**-CPN7435 Page 4 of 7 () HO EW RKS,Q$ product specification CPN7435a 07.08.16 HomeWorks® QS Wired seeTouch® Architectural Keypads Dimensions All dimensions are shown as in (mm) Front View Side View 49/s (116) . 0 0 il 2% 5/6 70 ' ( ) (8)- 11/s (27) Mounting and Parts Identification Wal'plate Adapter Wallate l Adapter Mounting p Keypad MScrews CD 4 Screw s s Sc 0 I® o °o 0 QP► iii nuuuw�F °U i Q III d ®� /3 /„...1yoo; 0 1 fa mrm,„{„„,fWallbox Keypad ° Replacement Kit 51 Luton® www.lutron.com 24/7 Technical Support 800.523.9466 RE( EIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: Keypad ISSUE DATE: 06/01/2022 Catalog #: RSDB-**-**-E-CPN7435; RSD-**-**-CPN7435 Page 5 of 7 () 79 EW RKS,QS product specification CPN7435a 07.08.16 HomeWorks® QS Wired seeTouch® Architectural Keypads Operation Status LEDs Show which keypad button has been activated. Keypad Buttons Press to activate desired levels or positions. IR Receiver Use a compatible IR remote to activate button functions. (not available for glass faceplates) Raise/Lower Buttons Lights increase or decrease in intensity and shades/ draperies move towards the open or close limit. I 6 Lutron. www.lutron.com 24/7 Technical Support 800.523.9466 RECEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: Keypad ISSUE DATE: 06/01/2022 Catalog #: RSDB-**-**-E-CPN7435; RSD-**-**-CPN7435 Page 6 of 7 () H�O EW RKS,QS product specification CPN7435a 09.12.16 HomeWorks® QS Wired seeTouch® Architectural Keypads Wiring Wiring Notes IEC PELV/NEC®Class 2 control wiring: • Keypad wiring may be in a daisy- 18 AWG(1.0 mm2) chain,star or T-tap configuration. Data link:twisted,shielded pair 22 to 18 AWG (0.5to1.0mm) • The total length of wire on a QS Contact Closure wired link is not to exceed 2000 ft 0 Notes (610 m). I O • The contact closure - ah�- inputs can be used • Up to 100 devices can be connected =MIIMI , mh�m� : to the QS wired link.This can ��MINPY� ? : with either dry contact include seeTouch®keypads along g�IMI: �t°"V> s closures or ground- with other devices as defined in th a a referenced solid-state HomeWorks QS software. - outputs. • An external power supply may be In.utzEll °®"W • The outputs must required depending on the total Input,VI I II o Qca'v n stay in the closed or current draw of all wired devices on I open states for at the processor link. o 0 least 40 ms in order to be recognized by the (3) 18 AWG keypad. (1.0 mm2) 0 0 0 g0 5. 0 0 0 o o� o oa• o 0 ki 1 2 3 4 5 1 2 3 4 5 I 0—Pins 1 and 2: 1 pair 18 AWG(1.0 mm2) for power 0 Pins 3 and 4: 1 pair 22 to 18 AWG (0.5 to 1.0 mm2) twisted/shielded for data (Can use Lutron®cable GRX-CBL-346S-500) 61 Lutron® www.lutron.com 24/7 Technical Support 800.523.9466 RE( EIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: Keypad ■ ISSUE DATE: 06/01/2022 Catalog #: RSDB-**-**-E-CPN7435; RSD-**-**-CPN7435 Page 7 of 7 I. S a H�_MEWC�RKS®QS ���� product specification CPN7435a 09.12.16 HomeWorks® QS Wired seeTouch® Architectural Keypads Colors and Finishes Architectural Matte Finishes Architectural Metal Finishes(wallplates only) II il White Ivory Satin Brass Bright Brass Bright Chrome WH IV SB BB BC Almond Light Clear Anodized Black Anodized Brass Anodized AL Almond Aluminum Aluminum Aluminum LA CLA BLA BRA Gray Brown Antique Brass Antique Bronze Satin Chrome GR BR QB QZ SC Black Taupe BL TP Satin Nickel Bright Nickel Gold SN BN AU Sienna Beige GWH CWH iiI t SI BE Green Glass with Clear Glass with 1rol White Paint White Paint — • Due to printing limitations,colors and finishes When ordering metal wallplates, shown cannot be guaranteed to perfectly it is recommended to order the keypad in Black(BL). match actual product colors. • Color chip keychains are available for more precise color matching: Architectural Matte Finishes-AM-CK-1 Architectural Metal Finishes-AMTL-CK-1 71 Luton® www.lutron.com 24/7 Technical Support 800.523.9466 RE r IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 LV.Panel Catalog #: Refer to Lutron BOM Page 1 of 4 aTEW RKS QS product specifications 369-381b 12.14.11 Low-Voltage Enclosure 0 Low voltage enclosures may be either surface-mounted or flush-mounted in an electrical closet or equipment room. Both the number of enclosures and the types of I° components within them are customized to fit the size, lighting plan,and design of a home. ° Low-voltage enclosures can be distributed throughout the home near the rooms they are controlling,to provide maximum flexibility during installation of the low-voltage wiring. 21-inch Low-Voltage Enclosure The 21-inch low-voltage enclosure provides a compact housing for mounting up to two HomeWorks®QS processors or up to two system interfaces and up to five wire landing . . . 0 0 . . . boards(QS-WLB). ° ° The enclosure accepts one 120 Vim- ° ° 0 ° (HQ-LV21-120)or 220-240 Vim- (L-LV21-230) O ° ° ° ° ° ° ° ° ° ° O feed to power the panel,which is self-contained in an enclosed area,thus allowing access to only the low-voltage connections when the enclosure Low-Voltage Enclosure cover is removed. Model Number ===0000 00000 0000=== 6 000®000 C� HQ-LV21-120 120 V^- Low-Voltage 000®000 Enclosure 0000=== ===000= L-LV21-230 220-240 Vti Low-Voltage 0000®== _______ Enclosure LUTRON pa b ® a 0000___ ===0000 ===0000 Low-Voltage Enclosure Cover www.lutron.com Lutron® REc E IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: gw94■ ISSUE DATE: 06/01/2022 LV.Panel Catalog #: Refer to Lutron BOM Page 2 of 4 H�OMEW RKSQS product specifications 369-381b 12.14.11 Low-Voltage Enclosure Specifications Model Numbers HQ-LV21-120 L-LV21-230 Power 120 V.-- Power Input 50/60 Hz 2 A (HQ-LV21-120) 220-240 Vim- Power Input 50/60 Hz 2 A (L-LV21-230) Regulatory Approvals UL,CSA,NOM (HQ-LV21-120) CE,0 C-tick (L-LV21-230) Environment Ambient operating temperature:32°F to 104°F(Ov°C to 40°C) Ambient operating humidity:0-90%humidity,non-condensing. Indoor use only. Mounting Enclosure may be surface-mounted or recess-mounted. Enclosure fits between standard 16 in(41 cm)on-center stud framing.Mount the enclosure so that line-voltage wiring will be at least 6 ft(1.8 m)from audio or electronic equipment and wiring. Mount Enclosure using one of the following methods(mounting hardware is not provided): a.Surface Mount—Use keyholes with bolts sufficient for 100 lb(45 kg) load, 1/4 in(M6)bolts recommended. b.Recess Mount—Use screws sufficient for 100 lb(45 kg)through the corners of the enclosure.Mount enclosure fully into the stud bay, with the back flush against the inner wall surface.Enclosure is 4.088 in(104 mm)deep past cover mounting tabs(including pedestal). Enclosure cover dimensions are 21.5 in x 15.386 in(546 mm x 391 mm). NOTICE:This equipment is air-cooled. Mount in a location where the vented cover wit not be blocked. 12 in(305 mm)of clearance in front of the vents is required. NOTICE:Power supply wit hum slightly and internal relays will click while in use. Mount in a location where such noise is acceptable. Dimensions Enclosure:21 in(533 mm)x 14.375 in(365 mm)x 4.088 in(104 mm) Cover:21.5 in(546 mm)x 15.386 in(391 mm) Construction Enclosure:16-gauge powder coated sheet metal. Cover:16-gauge powder coated metal cover.Cover is attached using four philips-head screws. Capacity Enclosure can accomodate two processors or system interface devices and five wire landing boards(QS-WLB). ra Examples: 1 Processor and 1 System Interface;2 Processors;or 2 Interfaces Line-Voltage Connections Use copper wire only,supply conductors rated at 167°F(75°C).Use supplied wire connections to connect to corresponding power supply harnesses. Warranty 8 Year Limited Warranty. http://www.lutron.com/Technical DocumentLibrary/HomeWorks_Warranty.pdf 2 Lutron® 24/7 Technical Support-800.523.9466 RE( EIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 LV.Panel Catalog #: Refer to Lutron BOM Page 3 of 4 H�MEW RKSQS product specifications 369-381b 12.14.11 Low-Voltage Enclosure Dimensions and Mounting 14.375 (365) Measurements shown as: • 13.285(337) in(mm) 7.750(197) Terminal Surface Mounting L + Shield Pedestal(4x) Line voltage e V #o Power Supply wiring entry DIN rail (non-IEC 6 E o 0 0 ® �F End Stop(5x) PELV/NEC® Class 2) Input Power o o 070 t+7° Switch A 18 (457) 21 (533) 20 0 0 0.312 (508) (7.9) C �0 0.430 o 00 0 -4- 11,1 (10.9) 0 o Jt o I 0.624 (15.8) o ." o0 oa o0 0 �-J :� • t t t 11.5(292) IEC PELV/NEC®Class 2 ONLY rtg!, FOI www.lutron.com Lutron® 3 RECEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 LV.Panel Catalog #: Refer to Lutron BOM Page 4 of 4 H�OMEW RKSQS product specifications 369-381b 12.14.11 Low-Voltage Enclosure Configuration . O � .1 _ Power Supply I '� ASPS-DH-1-60 (up to 2) omomomoomomoomo - ®omomoomomoomoo • fa III o • ICI HomeWorks®QS Processor HQP6-2-1 20 X�OM=W�I FKSQS� 4II XOM.EW(RKS.OS (up to 2) O - J R� - Al W rF;S74 I 0,7 lit lit QS Wire Landing Board ® ® ®ME ME ME QS-WLB ® °® (up to 5, 1 included) ra 4 I Lutron® 24/7 Technical Support-800.523.9466 RE( EIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ fy S ISSUE DATE: 06/01/2022 OS.Ceiling Catalog #: Refer to Lutron BOM Page 1 of 6 Radio Powr SavrTM Ceiling Wireless OccupancyNacancy Sensor 369480h 1 02.1616 Radio Powr SavrTM Wireless Occupancy/Vacancy Ceiling Sensor Lutron®Radio Powr SavrTM occupancy/vacancy sensors are wireless,battery-powered,passive infrared(PIR) sensors that automatically control lights via RF Thn7r0%,©mcommunication to compatible dimming and switching devices.These sensors detect the heat(IR radiation of V9.5 pm)from people moving within an area to determine I�'4 ..•I when the space is occupied.The sensors then wirelessly \,•�j transmit the appropriate commands to the associated Vb. I dimming and switching devices to turn the lights on or off oa =4 =v est automatically.They combine both convenience and exceptional energy savings potential along with ease of installation. Features • Wireless occupancy sensor has 3 settings available: Models Available Auto-On/Auto-Off,Auto-On Low-Light/Auto-Off,and • LRF=OCR2B-P-WH Manual-On/Auto-Off I I—Color Code • Auto-On Low-Light feature will turn lights on automatically Occupancy and Vacancy only if there is less than approximately 10 Lux(1 fc)of Frequency/Channel Code ambient light • LRF2-VCR2B-P-WH • Vacancy-only model available to meet California(U.S.A.) 1 Vacancy Only Title 24 requirements Available for Channel Code 2 Only • Uses Clear Connect®technology • Passive infrared motion detection with exclusive Lutron® Frequency/Channel Codes XCTTM Technology for fine motion detection Available • 360°coverage ranges from 324 ft2(30.2 m2)to 676 ft2 2=431.0-437.0 MHz(U.S.A.,Canada,Mexico,Brazil) (62.4 m2),depending on mounting height 3=868.125-869.850 MHz(Europe,U.A.E.) • Simple and intuitive adjustments available for Timeout, 4=868.125-868.4755 MHz(China,Singapore) Auto-On,and Activity settings 5=865.5-866.5 MHz(India) • Supports advanced occupancy features,such as 6=312.3-314.8 MHz(Japan) dependent occupancy groups and customizable occupied/unoccupied presets in some systems =433.05 434.79 MHz(Hong Kong,Macau) • Multiple sensors can be added for extended coverage. Color Code Refer to product specification submittal of receiving device WH=White to determine system limits Compatible RF Devices • Lens illuminates during test mode to verify ideal locations • For use with Lutron®products only • Multiple ceiling-mount methods available for different ceiling materials • Communicates to various wireless Lutron®systems" ki • Front accessible test buttons make programming easy * Contact Lutron®Customer Service at www.lutron.com for frequency/ i channel code compatibility with your particular geographic region,and for ra • 10-year battery life design integrating with other Lutron®lighting and shading products. • RoHS compliant OLUTRON,. SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number: RCEIVEt 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ lry ISSUE DATE: 06/01/2022 OS.Ceiling .9 Catalog #: Refer to Lutron BOM Page 2 of 6 Radio Powr SavrTM Ceiling Wireless OccupancyNacancy Sensor 369480h 2 02.1616 Specifications Regulatory Range • Lutron®Quality Systems Registered to ISO 9001:2008 LRF2-,LRF3-,LRF4-,LRF5-,LRF7- Standards Approved Local load controls must be located within 60 ft(18 m) LRF2 (USA and Canada) line-of-sight,or 30 ft(9 m)through walls,of a sensor. • cULus Listed LRF6- • FCC certified Local load controls must be located within 40 ft(12.2 m) • IC certified line-of-sight,or 23 ft(7 m)through walls,of a sensor. • Meets CA(U.S.A.)Energy Commission Title 24 Sensor Coverage Test requirements • Front accessible test button • COFETEL • Lens illuminates orange in response to motion during test • ANATEL mode and is visible from 60 ft(18 m) • SUTEL Wireless Communication Test LRF3- • Front accessible test button • CE marked(European Union) • Turn associated loads on and off • TRA type approval(United Arab Emirates) Timeout Options • CITC type approval(Saudi Arabia) • 1 minute* LRF4- • 5 minutes • SRRC type approval(Mainland China) • 15 minutes(default setting) • iDA registered(Singapore) • 30 minutes LRF5- Auto-On Options(Occupancy Versions Only) • WPC Type(India) • Enabled:Sensor turns lights ON and OFF automatically LRF6- (default setting). • *007YUUL0689 • Low Light:Sensor turns lights ON automatically only LRF7- in low ambient light conditions;sensor turns lights OFF automatically. • FCC • Disabled*`:Lights must be turned ON manually from Power/Performance dimming or switching device;sensor turns lights OFF • Operating voltage:3 V— automatically. • Operating current: 14 pA nominal Activity Options • Requires one CR 123 lithium battery • Low Activity: g (default setting) • 10-year battery life • Medium Activity: • Non-volatile memory(saved changes are stored during • High Activity: power loss) • Intended for use in high-activity,briefly occupied areas only. ki Environment " During the 15-second grace period that begins when the lights are • Temperature:32°F to 104°F(0°C to 40°C) automatically turned off,the lights will automatically turn back on in i response to motion.This grace period is provided as a safety and • For indoor use only convenience feature in the event the lights turn off while the room is still r occupied,so that the user does not need to manually turn the lights back Warranty on.After 15 seconds,the grace period expires and the lights must be manually turned on. • 5-Year Limited Warranty.For additional Warranty information,please visit www.lutron.com/ TechnicalDocumentLibrary/Sensor_Warranty.pdf OLUTRON,. SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number: R C E IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ fy ISSUE DATE: 06/01/2022 OS.Ceiling Catalog #: Refer to Lutron BOM Page 3 of 6 Radio Powr SavrTM Ceiling Wireless OccupancyNacancy Sensor 369480h 3 02.16,16 Installation Overview Mounting Sensor Setup Temporary mounting is optional to test sensor coverage • Sensor setup is available as a service by Lutron.For more and wireless communication before permanently installing information see the Sensor Layout and Tuning service the sensor. document(Lutron®P/N 3601235). Drop Ceiling(Compressed Fiber Ceiling Tile) Sensor Placement The mounting wire is provided for both temporary and • To detect motion,the sensor requires line-of-sight of permanent mounting of the sensor to ceiling tiles. It is room occupants.The sensor must have an unobstructed designed to allow temporary mounting,testing,and view of the room.DO NOT mount behind or near tall repositioning(if necessary)of the sensor without cabinets,shelves,hanging fixtures,ceiling fans,etc.The damaging a ceiling tile.Once the final position of the sensor cannot see through glass objects such as patio-or sensor has been chosen,the mounting wire should be shower doors. twisted together to permanently secure the sensor in • Hot objects and moving air currents can affect the place. performance of the sensor.To ensure proper operation, Solid Ceiling(Drywall, Plaster,Concrete,or the sensor should be mounted at least 4 ft(1.2 m)away Wood) from HVAC vents and light bulbs that are below the ceiling • Temporary mounting:Ten(10)temporary mounting strips line. can be purchased in the kit,L-CMDPIRKIT,for temporarily • The performance of the sensor depends on a temperature mounting and testing the sensor. differential between the ambient room temperature and • Permanent mounting:Screws and anchors(for drywall or that of room occupants.Warmer rooms may reduce the plaster)provided to mount the sensor. ability of the sensor to detect occupants. Recess Mount • Devices emitting Radio Frequency(RF)energy can affect • Do not recess mount sensor in a metal surface. the performance of sensors.To ensure proper operation, sensors should be mounted at least 4 ft(1.2 m)away from • Recess-mounting ring requires an opening of 3 in(76 mm) devices that emit radio waves(e.g.,microwave ovens, in diameter. wireless routers or other wireless devices). • Recess-mounting ring secures internally to ceiling.Sensor • For additional information on placing sensors,please see twists into the recess mounting ring and sits flush with the OccupancyNacancy Sensor Design and Application ceiling(see image below). Guide(P/N 368-3197)located at www.lutron.com. • Recess-mounting ring purchased as a separate kit: L-CRMK-WH. Rik I/...1 • • OLUTRON. SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number: RCEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ISSUE DATE: 06/01/2022 OS.Ceiling Catalog #: Refer to Lutron BOM Page 4 of 6 Radio Powr SavrTM Ceiling Wireless OccupancyNacancy Sensor 369480h 4 02.1616 Dimensions A ILUT©I rW II'•'ll 3.57 in 4in (90.7 mm) 2.85(72. mm) O(t1 C=Q C=Test I � V (22.5 0.88mmin)-* 1.13in (28.7 mm) ;;LUTRON0 SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number: R CEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: c cA ISSUE DATE: 06/01/2022 OS.Ceiling Catalog #: Refer to Lutron BOM Page 5 of 6 Radio Powr SavrTM Ceiling Wireless OccupancyNacancy Sensor 369480h 5 02.16.16 Range Diagrams Ceiling 8 ft • (2.4 m) Floor I ; IT 15ft :12ft 9ift 6ft 3ft 0 3ft 6ft 9ift 12ft: 15ft (4.6 m) (3.7 m) (21 m) (1.8 m) (0.9 m) (0.9 m) (1.8 m) (2.7 m) (3.7 m) (4.6 m) 18 ft x 18 ft(5.5 m x 5.5 m)maximum square coverage area when mounted- on an 8 ft(2.4 m)ceiling Sensor 13 ft(4.0 m)radius of coverage at floor when mounted on an 8ft(2.4 m)ceiling r Occupant -400 Sensor Coverage Chart(for sensor mounted in center of room) Ceiling Height Maximum Square Coverage Area* 8 ft(2.4 m) 18 ft x 18 ft(5.5 m x 5.5 m) 324 ft2(30.2 m2) �GG 9 ft(2.7 m) 20 ft x 20 ft(6.1 m x 6.1 m) 400 ft2(37.2 m2) n u 10 ft(3.0 m) 22 ft x 22 ft(6.7 m x 6.7 m) 484 ft2(44.9 m2) ra 12 ft(3.7 m) 26 ft x 26 ft(7.9 m x 7.9 m) 676 ft2(62.4 m2) * 12 ft(3.7 m)is the recommended maximum mounting height OLUTRON. SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number: REICEIVEC 08/18/2022 ASPEN BUILDING DEPARTMENT IIIIIIIIIIIIIIIIIIIIIIIII� IIIIIIIIIIIIIIIIIIIIII� PROJECT: Little Nell Spa & Gym TYPE: ISSUE DATE: 06/01/2022 OS.Ceiling Catalog #: Refer to Lutron BOM Page 6 of 6 Radio Powr SavrTM Ceiling Wireless OccupancyNacancy Sensor 369480h 6 02.16.16 Lens Masking Whenever possible,the sensor should be installed in a location where it cannot view areas outside the intended space,such as hallways or adjacent rooms. If this situation cannot be avoided,portions of the lens may be masked to block the view of the sensor into undesired areas.Ten(10)PIR Lens Masks may be purchased in the kit,L-CMDPIRKIT. Lens sections Lens sections PIR Lens Mask shown in gray shown in white are sold separately are not masked masked with labels (J32 (L-CMDPIRKIT) icn 064 � � 41111) 1111 110 Hallway falls within 0- mil Sensor, s coverage areara i nG � �LJjI ;;LUTRON0 SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number: R CEIVEP 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl R5,1■ ISSUE DATE: 06/01/2022 ■ Catalog #: MS-B102 Page 1 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 1 04.09.14 Maestro® Dual Technology Sensor Switch The Maestro®Dual Technology(Dual Tech)Occupancy Sensor Switch applies our exclusive XCT M Technology to the ultrasonic as well as the passive infrared technology in this sensor to create a product that can detect very fine motion,such as typing.This product also includes all of the great features found in the rest of the Maestro®sensor family,including:adaptive relay switching,smart ambient light detection,and simple button presses for changing settings.The Maestro®Dual Tech Occupancy Sensor Switch is available in single-circuit and dual-circuit versions. The single-circuit versions(MS-A102,MS-B102)can be used to meet many of the Title 20/24,ASHRAE 90.1,and IECC code requirements such as "automatic shutoff".The dual-circuit versions(MS-A202,MS-B202)can be ,—„-- used to meet many of the Title 20/24,ASHRAE 90.1,and IECC code -- requirements such as"automatic shutoff"and"multi-level lighting control". To find some examples of code-specific applications,visit www.lutron.com/energycodes Features • XCT®Technology for major, minor,fine, and very fine motion detection • 180°sensor field-of-view • Tamper-resistant PIR lens MS-A102-XX(Occupancy model) • Up to 900 ft2(81 m2)major motion coverage and 400 ft2(36 m2)minor MS-A102-V-XX(Vacancy model) MS-B102-XX(Occupancy model) motion coverage MS-B102-V-XX(Vacancy model) • Two Ambient Light Detect(ALD)options: -Learning ALD Mode: Uses adaptive algorithm. Sensor learns user's preferred light level over time. -Fixed ALD mode: Four selectable light level thresholds: Hi, Med, Low, Min • Occupancy models(MS-Al02-XX, MS-B102-XX, MS-A202-XX, MS-B202-)0()can be set to Auto-ON/Auto-OFF or Manual-ON/Auto-OFF per circuit • Dual-circuit models(MS-A202, MS-B202)meet Title 24 requirements for multi-level lighting control. LIATICIN • Single-circuit"Vacancy"models(MS-Al02-V-XX, MS-B102-V-)X)available to meet Title 24/Title 20 requirements for vacancy sensors. • Adjustable timeout for each circuit(1,5, 15,or 30 minutes) • Sensitivity adjustment -PIR(Hi, Med, Low, Min) -Ultrasonic(Hi, Med, Low,Off) • Switches all lighting loads: incandescent, halogen, ELV, MLV, CFL, LED, ra magnetic fluorescent,electronic fluorescent• Switches fan loads at 120 Vti MS-A202-XX(Occupancy model) • MS-B102, MS-B102-V work with Maestro®accessory switches in MS-B202-XX(Occupancy model) multi-location applications Notes: • MS-A models DO NOT require neutral wiring,while the MS-B models DO • °xx in the model number represents require neutral wiring. color/finish code.See Colors and Finishes at end of document. • Wallplate not included. OLUTRON® SPECIFICATION SUBMITTAL Page 1 Job Name: Model Numbers: Job Number: R C E IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl I. ISSUE DATE: 06/01/2022 Catalog #: MS-B102 Page 2 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 2 04.09.14 Specifications Advanced Features Regulatory Approvals Switching • UL®Listed to U.S. and Canadian safety requirements • Adaptive zero-cross switching—maximizes (applies only to MS-B102, MS-B102-V, MS-B202) relay life by switching at the point of minimum • NOM certified energy on the AC power curve(patent pending). • Title 20/24 certified lighting control device Actively adapts to variations in relay timing. —Complies with Title 20 and Title 24 section 110.9 Additional Information on Sensors Power/Load Control • For single-circuit PIR Maestro®Occupancy Sensor Switch models, please see Lutron®P/N • 120-277 V-- 50/60 Hz 369666 Key Design Features • For Maestro®Occupancy Sensor C.L.Dimmer • Dual Sensing Technology models, please see Lutron®P/N 369748 • Switches all lighting loads • For dual-circuit PIR Maestro Occupancy Sensor • 6 A of lighting load per circuit at 120-277 V Switch, please see Lutron®P/N 369758 • 4.4 A(1/6 HP)of fan load per circuit at 120 Vti • For more information, please see www.lutron.com/occvacsensors • Crush/tamper resistant lens • Lutron Technical Hotline: 1.800.523.9466. • Smart Ambient Light Detection(ALD) • Fixed Ambient Light Detection • Adaptive zero-cross switching algorithm for extended relay life(patent pending) • XCTT.Technology for major, minor,fine, and very fine motion detection • Programmable Circuit Swapping eliminates need for rewiring to reassign circuits after installation of a dual-circuit product. (patent pending) • Product ground current does not exceed 0.5 mA Environment • Ambient operating temperature: 32°F to 104°F (0°C to 40°C),0%-90% humidity, non-condensing. Indoor use only. Warranty • 5-Year Limited Warranty. For additional Warranty information, please visit www.lutron.com/ TechnicalDocumentLibrary/Sensor_Warranty.pdf Sensor Detection ra_ Lutron®Dual Tech sensors operate by triggering initial occupancy using PIR technology,and maintain occupancy using both ultrasonic and PIR technology. ;;=LUTRON,„ SPECIFICATION SUBMITTAL Page 2 Job Name: Model Numbers: R CEIVED Job Number: 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl ■ ISSUE DATE: 06/01/2022 ■ Catalog #: MS-B102 Page 3 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 3 04.09.14 Custom Settings Custom Settings - Details Default settings shown in bold Ambient Light Detection(ALD)mode 0 -Timeout Lights turn on only when natural light in the room is • 30 min below the set threshold. • 15 min — Learning:The ambient light threshold adjusts to • 5 min the user's preference via manual interaction with • 1 min the sensor switch. — Fixed:Choose a fixed ALD light level from four Mode-Sensor Modes pre-set options: Lights automatically turn off in all sensor modes High, Medium, Low,and Minimum • Occ-Occupancy mode(No ALD)1'2'3 • Lrn-Occupancy with learning ALD mode Manual Off-While-Occupied Options • Fixd-Occupancy with fixed ALD mode ENABLED(default setting) • Vac-Vacancy mode(No ALD)2'3 — When the sensor switch is manually turned off, 1 MS-Al 02-XX,MS-B102-%%default is Occ 2 MS-A102-V-%X,MS-B102-V-XX is locked as Vac the sensor switch will not turn the lights back on 3 MS-A202-XX,MS-B202-XX defaults are:Circuit 1-Occ,Circuit 2-Vac automatically while the room is occupied. a0� - Ultrasonic Sensitivity — Once the room is vacated,the Auto-On feature • High returns to normal operation after the timeout • Med period has expired. • Low — This may be the preference in conference rooms • Off or classrooms while viewing presentations.This feature requires motions to keep the lights off. FIR - Passive Infrared Sensitivity DISABLED • High — When the sensor switch is manually turned off, • Med the Auto-On feature will return to normal operation • Low after 25 seconds. • Min — This may be the preference in a restroom if the Additional Settings user always wants the lights to turn on upon entering and the lights to turn off when the room Fixed ALD Light Level is vacant. • Hi • Med Walk-Thru Mode • Low* ENABLED1 • Min — If motion is not detected within 3 minutes after "Low"is the default setting for any sensor that is set by the user to,Occupancywlth fixed ALD mode initial occupancy,the lights will turn off after 3 minutes,instead of the current timeout. Off-While-Occupied — This setting may be the preference in commercial • Enabled applications where personnel may briefly trigger ra • Disabled sensors during non-working hours. DISABLED(default setting) — When motion is detected,the lights will ALWAYS Walk-Thru Mode remain on for the entire timeout duration, • Enabled regardless of the duration of occupancy detection. • Disabled 1 minute timeout would be overridden if walk-thru mode is also ENABLED ;;=LUTRON,,, SPECIFICATION SUBMITTAL Page 3 Job Name: Model Numbers: R CEIVED Job Number: 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl ■ ISSUE DATE: 06/01/2022 ■ Catalog #: MS-B102 Page 4 of 14 Maestro. Dual Technology Occupancy Sensor Switch Sensor 369773c 4 04.09.14 Load Type and Capacity Neutral Vacancy Number Voltage/Load Type/Maximum Load Minimum 3-Way with Multi-Location Control Connection Only °t (Anywhere in Gang)' Load Mechanical with Accessory Required Circuits Switch Switch MS-A102 1 0 A MS-A102-V ✓ 1 0 A MS-A202 2 120-277 Lighting 6 A 2 0 A MS-B102 ✓ 1 120 V-s- Fan 4.4 A(1/6 HP)3 0 A ✓ ✓ MS-B102-V ✓ ✓ 1 0 A ✓ ✓ MS-B202 ✓ 2 0 A ✓ 1 Ratings shown are per circuit. 2 Sensor Switch Load Type:Designed for use with permanently installed incandescent,halogen,MLV,ELV,CFL,LED,magnetic fluorescent,and electronic fluorescent lighting loads. 3 When controlling light and fan loads simultaneously on a single-circuit,maximum load capacity per circuit is 4.4 A at 120 V--. Sensor Switch Placement • The sensor switch performs better with an unobstructed view of room occupants. • Hot objects and moving air currents can affect the performance of the sensor switch.The sensor switch performs best when located 6 ft(1.8 m)or more away from hot objects or moving air currents. • The PIR performance depends on a temperature differential between the ambient room temperature and that of room occupants.Warmer rooms may reduce the ability of the sensor switch to detect occupants. • The ultrasonic performance can be affected by air currents and moving objects. Consider the effects of fans, HVAC vents,open windows, or moving objects when installing the sensor switch. • If the sensor sees a specific area that is not desired(e.g., hallway), Lutron offers a lens mask kit(Lutron.P/N 50013614)that can be ordered through Tech Support(1.800.523.9466).Alternatively, selectively placing opaque tape(e.g., painter's tape, electrical tape, masking tape)over certain parts of the lens can limit it's field of vision to block undesired detection areas. Masking the lens may effect ALD performance, but DOES NOT block ultrasonic frequencies. Definitions Major motion:movement of a person entering or passing through an area. Minor motion:movement of a person occupying an area and engaging in small activities(e.g., reaching for a telephone,turning the pages of a book,opening a file folder, picking up a coffee cup). Fine Motion:movement of a person occupying an area and engaging in very small activities(e.g.,reading a R� magazine). (A711 Very Fine Motion:movement of a person occupying an area and engaging in very small activities(e.g.,typing on ra a keyboard). ;;=LUTRON,,, SPECIFICATION SUBMITTAL Page 4 Job Name: Model Numbers: R CEIVED Job Number: 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl I rio ISSUE DATE: 06/01/2022 Catalog #: MS-B102 ii44904 Page 5 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 5 04.09.14 Sensor Switch Placement(continued) NEMA WD7 Coverage Passive Infrared Ultrasonic Coverage Beam Diagram (For Reference Only) Major motion coverage:900 ft2(81 m2) (For Reference Only) Minor motion coverage:400 ft2(36 m2) 15 ft 20ft_ fif//// 30 ft (6 m)(9 m) 1 10 ft 20ft �� (3 ml (6 m) 10(3m ft)_ 10 ft 11101 5 ft (3 m) 0 (1.5 m) 0 I 10ft 3 m) 7 10 ft /fr..\\\----__.- 11111 20 ft (3 m) 5 ft (6 m) 30 ft (9 m) 20 ft_ 10 ft 1 (6 m) (1 m) / j// jA 4ft 4ft I 5 ft (1.2 m) (1.2 m)� (4.5 m) 0 10 ft 20 ft 30 ft 0 10 ft 20 ft 0 5 ft 10 ft 15 ft 20 ft 25 ft 30 ft (3 m) (6 m) (9 m) (3 m) (6 m) (1.5 m) (3 m) (4.5 m) (6 m) (7.5 m) (9 m) Test Room Dimensions:37 ft x 38 ft(11.28 m x 11.6 m) Ultrasonic Frequency: 40 kHz Test Floor Surface Material:Carpet Sensor Coverage Angle:180° Major motion coverage:Initial trigger motion detection Minor motion coverage:Maintained motion detection 1I 1 ;;=LUTRON,,, SPECIFICATION SUBMITTAL Page 5 Job Name: Model Numbers: i Job Number: RCEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl ■ Do9 ISSUE DATE: 06/01/2022 4 Catalog #: MS-B102 Page 6 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 6 04.09.14 Dimensions - Single-Circuit Operation MS-A102, MS-A102-V, MS-B102, MS-B102-V Measurements shown as: in(mm). Front View Side View U. Tap button o (tap on/off) I ( ) Programming Or •O - �iIMj>_li LEDs —o l Timeout Ultrasonic Button •$ Bensitivity Button 0 01 aom •RI MI •15 on= •Med Lamm 4�%s .5 .Law Sensor Mod n�plR — Button Mode ."�, .� PIR `�' `�' — -occ Sensitivity I •Rx .Med Button •rxd • w •Vac I . 'MI5 d —i Imo!=�I�/P Sensor LED 1 �� Ultrasonic (behind lens) o Transducers Pulses during o ( ) Test mode. o 0 I PIR Sensor lens 'I 1011 2e5/ie Yl < (30)1 (75) H 5/16(8) Mounting F1/a(a) \e \ �\ Mounting screws Adapter mounting screws r. ,,,,, , 0 1 me. �) �I �I it1.1 (� 111 liti,I ra e 7 i j I - Wallbox* ...) f) * Recommended Wallbox dimensions: Sensor Switch 3.5 in(89 mm)o x 8 in(7e mm)H X z in(51 mm)w Wallplate Adapter/Wallplate • (sold separately) ;;=LUTRON,,, SPECIFICATION SUBMITTAL Page 6 Job Name: Model Numbers: i Job Number: R C E IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl I IF> ISSUE DATE: 06/01/2022 94 Catalog #: MS-B102 Page 7 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 7 04.09.14 Dimensions - Dual-Circuit Operation MS-A202, MS-B202 Measurements shown as: in(mm). Front View Side View r ' A NON O Top Tap button � Controls Circuit 1 ) (tap on/off) Programming Mi=l=lok LEDs o' , O Bottom button Tap 1[1 • Controls Circuit 2 Timeout (tap on/off) Button ISO b,��Ultrasonic .30m ."i Sensitivity ova 4"%s •15 •'.5 man :MButton (119) _ •1 ,,,,,. ,__. •od ,__. ,__. — Sensor Mod i ,,,,.,,,,,,,,,,., , i�Button ModeLam, PIA�pIR —' — °� "' Sensitivity I •rr" :Med Button •Fixdd•Yac —1 —11 Sensor LED 0 (behind lens) Ultrasonic Pulses during o ( ) Transducers Test mode. o 0 I PIR Sensor lens no { 10B III (75) t H� (30) 5/16(8) Mounting —1/8(3) gia it* Mounting screws I Adapter mounting screws 0Ir,- liti, e nd �y ro, I,i r Wallbox* ..., ,,,,,, * Recommended Wallbox dimensions: Sensor Switch 3.5 in(89 mm)o x 3 in(76 mm)H X 2 in(51 mm)w Wallplate Adapter/Wallplate • (sold separately) ;;=LUTRON,,, SPECIFICATION SUBMITTAL Page 7 Job Name: Model Numbers: I — Job Number: RCEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.Wall ISSUE DATE: 06/01/2022 Catalog #: MS-B102 Page 8 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773, 8 C8.09.1 Wiring Diagrams - Single-Circuit Wiring Diagram 1 Single Pole Wiring-Single-Circuit(MS-A102,MS-A102-V) Black o Red •Line/Hot 0 Green/Yellow 120-277 V-- of Load 50/60 Hz it Ground Green Neutral Wiring Diagram 2 Single Pole Wiring-Single-Circuit(MS-B102,MS-B102-V) /Black Black I 0 0 •Line/Hot ' Blue White 11. Load 120-277 Green 50/60 Hz -Ground ONeutral F01 continued on next page... ;;;:,LUTRON® SPECIFICATION SUBMITTAL Page 8 Job Name: Model Numbers: Job Number: R C E IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl I VIVI ISSUE DATE: 06/01/2022 Catalog #: MS-B102 Page 9 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 9 04.09.14 Wiring Diagram 3 120 V—Multi-Location Installation with Maestro-Accessory Switches(MS-B102,MSB102-V) Note:Dual Tech Sensor Switch can be MA-AS or MA-AS or MS-B102 or installed in any location. MSC-AS MSC-AS MS-B102-V However,optimum performance of sensor may depend upon installation location,see sensor Blue Blue Blue switch placement guidelines on 0 0 o page 4. Line/Hat Black Brass A � Black Brass 1R s Black @ EtBlack a - a 120 V— 1 0 I 1 0 1 v White Load 50/60 Hz Green� Green Green =Ground Ground- Ground_ Neutral o 1, Wiring Diagram 4 220/240 V--Multi-Location Installation with Maestro:Accessory Switches(MS-B102,MSB102-V) Note:Dual Tech Sensor Switch can be MA-AS-277 or MA-AS-277 or MS-B102 or installed in any location. MSC-AS-277 MSC-AS-277 MS-B102-V However,optimum performance of sensor may depend upon installation location,see sensor Blue Blue Blue switch placement guidelines on o 0 o page 4. Line/Hot ill Black Red Black Red Black Black [1 Black a a— D d 220/240 V-- 1 0 1 1 0 1 v o White Load 50/60 Hz Green� Green Green =Ground Ground- Ground_ Neutral o V Wiring Diagram 5 277 V--Multi-Location Installation with Maestro®,Accessory Switches(MS-B102,MSB102-V) Note:Dual Tech Sensor Switch can be MA-AS-277 or MA-AS-277 or MS-B102 or installed in any location. MSC-AS-277 MSC-AS-277 MS-B102-V However,optimum performance r,, of sensor may depend upon .' t'A installation location,see sensor ki I Blue Blue Blue switch placement guidelines on i 0 I 1 01 o page 4. i Line/Hat Black Red j Black Red ®Black[^,Black A _ 7 n o 277 V-- 1 0 I 1 0 1 v White Load 50/60 Hz Green� Green Green =Ground Ground- Ground Neutral O W JWTRON® SPECIFICATION SUBMITTAL Page 9 Job Name: Model Numbers: Job Number: CE IVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl I Jr, ISSUE DATE: 06/01/2022 Catalog #: MS-B102 ,40904 Page 10 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 10 04.09.14 Wiring Diagrams - Single-Circuit(continued) Wiring Diagram 6 3-Way Installation-Single-Circuit(MS-B102,MS-B102-V) MS-B102 Standard Mechanical Switch Line/Hot jolt Black o Black A ir Note:Dual Tech Sensor Switch can be installed in any location.However,optimum �p� ' Yellow performance of sensor may depend upon I I, installation location,see sensor switch 17 x Blue 61 Jumperrwi placement guidelines on page 4. 2 White ® (included) 120-277 V-- to o j. Different 50/60 Hz 0 color Green o 0 screw Load Ground = Ground Neutral 0 3-Way Installation For retrofit 3-way installations the mechanical switch needs to be rewired as shown in the diagram below after wiring the Dual Tech Sensor Switch.Otherwise the 3-way installation will not work as expected.Single Pole mechanical switches may also be used in a 3-way installation with MS-B102,MS-B102-V and MS-B202 models. 1.Connect Ground:Ensure the bare copper or green ground wire from the wallbox is connected to the green ground screw of the mechanical switch. 2.Tag circuit Common:Your 3-way mechanical switch should have three screw terminals,two of the same color,and one of a different color.Tag the wire that is connected to the screw terminal of a different color. 3.Identify the wire that matches the color of the wire you connected to the blue wire of the Maestro®Dual Technology Occupancy Sensor Switch.Connect this wire to one of the two terminals of the same color. 4.Combine the tagged wire,the remaining wire and yellow jumper wire(included)using a wire connector.Connect the other end of jumper wire to the different color screw. Traditional 3-Way Mechanical Switch Wiring 3-Way Mechanical Switch Wiring with Dual Tech Sensor Switch 0 0 • • 0 CM jill Traveler 'I II Traveler Rewire to, II II Traveler(to Blue wire) RI i Yellow Jumper ® Tagged Wire Il Common I - wire(included) (Common) )I i- \Different II i 00 !\Different t� screw screw Traveler o • (to Black wire) _ Ground _ Ground OLUTRON® SPECIFICATION SUBMITTAL Page 10 Job Name: Model Numbers: Job Number: RCEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.Wall ISSUE DATE: 06/01/2022 Catalog #: MS-B102 Page 11 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 11 011.09.1.1 Wiring Diagrams - Dual-Circuit Wiring Diagram 1 Wiring Diagram 2 Single Pole,Single Breaker Feed Wiring- Single Pole,Single Breaker Feed Wiring- Dual-Circuit(MS-A202) Dual-Circuit(MS-B202) L Black o Red Load 1 Black I_ o l Black Load 1- Line/Hot i M ° Line/Hot i e Blue LH CO _ �h Qa' Black-Orange o Black-Orange W Hck-Orange White Black-Orang Load 2 � Load 2 Green/Yellow ;j ' 3 120-277 V-- Ia o I 120-277 Vim- = o 50/60 Hz I50/60 Hz Green "I Ground 4 Green Ground Neutral Neutral - O O Wiring Diagram 3 Single Pole,Two Breaker Feed Wiring: Dual-Circuit(MS-A202) Line/Hot LBlack o Red W • Load 1 MT Line/Hot 4J Q . W Black-Orange Black-Orange Load 2 Wiring must comply Green/Yellow with NEC®code for 120-277 V-- I I o wiring multiple branch 50/60 Hz .II circuits.Where two or Ground ii Green more branch circuits Neutral supply devices or 0 equipment on the same yoke,a means Wiring Diagram 4 to simultaneously Single Pole,Two Breaker Feed Wiring: Dual-Circuit(MS-B202) disconnect the ungrounded conductors supplying Line/Hot p Black L Black , those devices shall be • - Load 1 rill u, Blue ® provided at the point Line/Hot 8 0 T. 7 at which the branch Black-Orange W i9`Black-Orange va • ;, Load 2-- circuits originate. _ ,g White 120-277 V� Io I 50/60 Hz Gree en Neutral =Ground O continued on next page... ;L.UTRONO SPECIFICATION SUBMITTAL Page 11 Job Name: Model Numbers: Job Number: —IT RCEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl I rio ISSUE DATE: 06/01/2022 Catalog #: MS-B102 4490,1 Page 12 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 12 04.09.14 Wiring Diagrams - Dual-Circuit(continued) Wiring Diagram 5 3-Way Installation,Single Breaker Feed Wiring:Dual-Circuit(MS-B202) NOTE: Do not use Maestro®accessory switches with MS-B202. MS-B202' Standard Mechanical Switch z,s Black I o I Black I - b Load 1 Line/Hot 0 °4 • a a Blue SSS=���JJJ ® Note:Optimum performance of sensor Black-Orange a Black-Orange may depend upon installation White E—Yellow Jumper r� Different location,see sensor switch 120-277 V� o� p wire(included) 50/60 Hz Green ono o color placement guidelines on page 4. screw Ground Ground _ Load 2—rat O Neutral W Wiring Diagram 6 3-Way Installation,Two Breaker Feed Wiring:Dual-Circuit(MS-B202) Wiring must comply with NEC®code for wiring multiple branch circuits.Where two or more branch circuits supply devices or equipment on the same yoke,a means to simultaneously disconnect the ungrounded conductors supplying those devices shall be provided at the point at which the branch circuits originate. MS-B2021 Standard Mechanical Switchz3 Line/Hot Black Black ® Note:Do not use Maestro®accessory Load t switches with MS-B202. 000 BE1 Blue ! 1 4 e ne/Hot A Black-Orange'i 72 Black-Orange z i White r DiffeF Yellow Jumper li o colorrent wire(included) Note:Optimum performance of sensor 120-277 V� Green o o screw may depend upon installation 50/60 Hz Ground location,see sensor switch Load 2 placement guidelines on page 4. Ground- Neutral O W RI ra 1 Dual Tech Sensor Switch can be installed in any location. - 2 Mechanical switch may be wired to either circuit,and will control both.Do NOT wire mechanical switch to both circuits. 3 You may use no more than one mechanical switch with a dual-circuit Dual Tech Sensor Switch. ;;=LUTROM SPECIFICATION SUBMITTAL Page 12 Job Name: Model Numbers: I Job Number: RCEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl ■ Ey ISSUE DATE: 06/01/2022 Catalog #: MS-B102 „40904 Page 13 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 13 04.09.14 3-Way Installation For retrofit 3-way installations the mechanical switch needs to be rewired as shown in the diagram below after wiring the Dual Tech Sensor Switch.Otherwise the 3-way installation will not work as expected.Single-Pole mechanical switches may also be used in a 3-way with MS-B102,MS-B102-V and MS-B202 models. 1.Connect Ground:Ensure the bare copper or green ground wire from the wallbox is connected to the green ground screw of the mechanical switch. 2.Tag circuit Common:Your 3-way mechanical switch should have three screw terminals,two of the same color,and one of a different color.Tag the wire that is connected to the screw terminal of a different color. 3.Identify the wire that matches the color of the wire you connected to the blue wire of the Maestros Dual Technology Occupancy Sensor Switch.Connect this wire to one of the two terminals of the same color. 4.Combine the tagged wire,the remaining wire and yellow jumper wire(included)using a wire connector.Connect the other end of jumper wire to the different color screw. Traditional 3-Way Mechanical Switch Wiring 3-Way Mechanical Switch Wiring with Dual Tech Sensor Switch CaTraveler 'I ill II Traveler RewireII II Traveler(to Blue wire) Yellow Jumper ® Tagged Wire Common wire(included) (Common) nr, Different 11 iP \Different screw 1� screwr Traveler „' a O• (to Black OR Black-Orange wire) Ground _ Ground How Loads Operate in 3-Way with Dual-Circuit Sensor Switch (MS-B202) Initial Load State After flipping 3-way mechanical switch Circuit 1 Circuit 2 Circuit 1 Circuit 2 When All Lights are OFF Off Off On On When All Lights are ON On On Off Off On Off Off Off When One Circuit is ON Off On Off Off 'C ;;=LUTRON,,, SPECIFICATION SUBMITTAL Page 13 Job Name: Model Numbers: I Job Number: R C E IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: OS.WaIl ■ fy ISSUE DATE: 06/01/2022 Catalog #: MS-B102 ii44904 Page 14 of 14 Maestro® Dual Technology Occupancy Sensor Switch Sensor 369773c 14 04.09.14 Colors and Finishes Gloss Finishes Satin Finishes White Ivory Hot Merlot Plum Turquoise WH IV HT MR PL TQ Almond Light Almond Taupe Eggshell Biscuit Snow AL LA TP ES BI SW . II Gray Brown Palladium Midnight Sienna Terracotta GR BR PD MN SI TC mil - Black Greenbriar Bluestone Mocha Stone Goldstone BL GB BG MS GS Desert Stone Stone Limestone Sea Glass DS ST LS SG ki, ra • Due to printing limitations, colors and finishes shown cannot be guaranteed to match actual product colors perfectly. • Color chip keychains are available for more precise color matching: Gloss Finishes: DG-CK-1 Satin Finishes: SC-CK-1 ;;=LUTRON® SPECIFICATION SUBMITTAL Page 14 Job Name: Model Numbers: Job Number: R C E IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 Processor Catalog #: HQP7-2 Page 1 of 7 H�EW RKS product specifications 3691127b 01.07.20 HomeWorks QSX Processor The HomeWorks QSX processor' provides control and communication to HomeWorks system (HUH® [®®i :•I ji 7,1 components. I The Ethernet links allow communication to the HomeWorks designer software, integration with fl11f0 E® 02a1n� 4 1 third-party systems and communication between HomeWorks QSX Processor multiple processors. HomeWorks QSX processors HQP7-2 24-36 V—250 mA SELV NEC®Class 2 may be connected using either an Ethernet hub/ I lutron.com+1.844.LUTRON1 TRO02.0657 switch or router, or by using Ethernet directly W Ll,++= +4ao2o.n,+= a�—,oA from a PC to the processor(s). Clear Connect- ie�®®WM Type X Gateways cannot be wired directly to the Ethernet port on a HomeWorks QSX processor. i See page 5 for details.All processors on a project ®®rO®®® 1 must be connected to a single network.The HomeWorks designer software and all integration equipment must be connected to the same network as the processors.The HomeWorks QSX processor is required when using the Clear Connect-Type X Gateway for control of residential Ketra light sources. See Lutron Spec Submittal 3691128 at www.lutron. corn for the complete details on Clear Connect- Type X Gateway. The processor is powered from the QSPS-DH-1-75-H power supply. Refer to the HomeWorks designer software to determine link power requirements. The QSX processor can be installed in a HQ-LV21, L-LV21, L-LV14,or PDx control panel. Processor Capabilities Each QSX processor has 1 or 2 links(depending on model number)that can be individually configured as one of two types: • HomeWorks QS wired device link 99 devices/512 zones Fa • HomeWorks Clear Connect-Type A 99 devices/100 zones Model Numbers HQP7-1 HomeWorks QSX 1-link processor' HQP7-2 HomeWorks QSX 2-link processor' HQP7-MDU-1 HomeWorks QSX 1-link MDU processor1•2 HQP7-MDU-2 HomeWorks QSX 2-link MDU processor1•2 1 The HomeWorks QSX processor requires Lutron Designer software 16.x or greater to operate. 2 Only available for multi-dwelling unit projects.Contact your local dealer or Lutron representative for more information. Oust( er S.A.Assistance:anadaRECEIVED www.lutron.com/support 1 1.844.LUTRONI U.S.A./Canada +44.(0)20.7680.4481 (Europe) 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 Processor Catalog #: HQP7-2 Page 2 of 7 H� O.t RKS product specifications 3691127b 01.07.20 HomeWorks QSX Processor Specifications Model Number HQP7-1; HQP7-2; HQP7-MDU-1; HQP7-MDU-2 Power Processor (P): 24-36 V— 250 mA Links(L1/L2): 24-36 V= 2 A per link Typical Power 4.2 W;8 Power Draw Units(PDUs) Consumption Test conditions:Two Ethernet links connected, both device links in use Regulatory Approvals cULus, NOM Environment Indoor use only.32°F to 104°F(0°C to 40°C),0%to 90%humidity, non-condensing Heat Generated 15 BTU/hr—typical (24 BTU/hr with 2 links at 2 A each output) Cooling Method Passive Cooling Power Failure Memory System data stored in non-volatile memory.Timeclock retention for 10 years Internal Timeclock 1 minute per year Miswire Protection All terminal block inputs are over-voltage and miswire protected against wire reversals and shorts Low-Voltage Link Two pair— one pair 18 AWG(0.75 mm2),one pair 18 to 22 AWG Wire Type (0.34 to 0.75 mm2)twisted shielded — IEC PELV/NEC®Class 2 cable Low-Voltage Power 18 AWG(0.75 mm2) Wire Type Communications Ethernet, RS485(QS, RF) Link Capacities HomeWorks QS Wired Device Link 99 devices/512 zones HomeWorks Clear Connect-Type A Link 99 devices/100 zones ESD Protection Meets or exceeds the IEC 61000-4-2 standard Surge Protection Meets or exceeds ANSI/IEEE C62.41 standard Mounting Mounts in HQ-LV21, L-LV14, L-LV21,or PDx-control panel Dimensions With terminal blocks(as shown):4.25 in(108 mm)x 3.94 in(100 mm) Without terminal blocks: 4.25 in(108 mm)x 3.54 in(90 mm) Connections 4-pin removable terminal blocks. 1 for HQP7-1,2 for HQP7-2. I One 4-pin removable terminal block*for Power Input. Two RJ45 standard Ethernet connections. ra *Each terminal will accept up to two 18 AWG(0.75 mm2)wires. Warranty www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf Customer Assistance:RE C E IVE D www.lutron.com/support 2 1.844.LUTRONI (U.S.A./Canada) +44.(0)20.7680.4481 (Europe) 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 Processor Catalog #: HQP7-2 Page 3 of 7 i H�EW RKS product specifications 3691127b 01.07.20 HomeWorks QSX Processor Dimensions Dimensions shown as: in(mm) Front View Side View 4.25 )1 2.38 (108) ` (60.5) - _ A (®HHH) PH I� F� �7 �I 111D E® °mm'°,-= 0 E HomeWorks QSX Processor HQP7-2 ail 3.54 3.94 24-36 V=250 mA SELV NEC.Class 2 lutron.com+1.844.LUTRON1 (90) (100) LUTRON+44.(0)20.7702.0657 L1.24 V—1 O A L2.24 V—1 D A i__®®___e® m 11 1-®®®®�Lonnni._, , [Iiil, Fa Customer.S.A.Assistance:/ anadaRECEIVED www.lutron.com/support 3 1.844.LUTRON1 U.S.A./Canada +44.(0)20.7680.4481 (Europe) 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ISSUE DATE: 06/01/2022 Processor Catalog #: HQP7-2 Page 4 of 7 H�WW RKS product specifications 3691127b 01.07.20 HomeWorks QSX Processor Mounting O:A' i/4 `o DIN Rail i„���,���' 1 Power Supply 6 '.._. " (QSPS-DH-75-H) a s • (( /� _ (4)Red Link 1(optional) IINI I �� . (3)Red Link 2(optional) 4111, _ (2)Red+V Processor Power (11)Black COM(Common) • i gilt T151019 o Q Wire Landing Boards (QS-WLB) L-LV21/HQ-LV21 I ' LJ 1 II ro —_...�iiR.j .3 giallo i 1 1 - 1 I LIMN. I RI --- l a o o o il 1 PO a ®�® it ®� 1 oI Ili 1 L-LV14 PDx-Control Panel Customer Assistance: www.lutron.com/support 4 1.844.LUTRONI (U.S.A./Canada) RECEIVE" +44.(0)20.7680.4481 (Europe) 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 Processor Catalog #: HQP7-2 Page 5 of 7 HI EW RKS product specifications 3691127b 01.07.20 HomeWorks QSX Processor Wiring Diagrams—Networking Connection using an Ethernet hub/switch/router Ethernet Router WAN LAN ,., Ethernet cable:Cat5e(minimum) 328 ft(100 m)maximum Maximum of 5 processors can be daisy chained together. sal - 41I11inI HomeWorks QSX HomeWorks QSX Processor HQP7-2 Processor HQP7-2 Ethernet Router WAN LAN Err] Ethernet cable:Cat5e(minimum) 328 ft(100 m)maximum 4111.1.10 '-• IEEE 802.3af-2003 or 802.3at-2009 compliant HomeWorks PoE Injector/supply Clear Connect- by others. Type X Gateway HQP7-RF HomeWorks QSX HomeWorks QSX Maximum of 5 devices can be Processor HQP7-2 Processor HQP7-2 daisy chained together. ra Customer.S.A.Assistance:/ anadaRECEIVED www.lutron.com/support 5 1.844.LUTRONI U.S.A./Canada +44.(0)20.7680.4481 (Europe) 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ISSUE DATE: 06/01/2022 Processor Catalog #: HQP7-2 Page 6 of 7 Hr OMEW RKS product specifications 3691127b 01.07.20 HomeWorks QSX Processor Wiring Diagrams—HomeWorks Clear Connect-Type A HomeWorks QSX Processor HomeWorks Clear Connect- HomeWorks QS Hybrid Repeater HomeWorks HQP7-2 Type A Device HomeWorks Clear Connect- 0 Clear Connect- Type A Device Type ADevice / 30ft(9 mmaximum) iill Li a I .IM- 1 30ft(9 m) 30ft(9 m) maximum maximum HomeWorks Clear Connect- sx >1 HomeWorks Clear Connect-Type A Link* Type A Link* 60 ft(18 m)maximum 1000 ft(305 m)maximum wire length per run 1000 ft(305 m)maximum wire length per run * HomeWorks Hybrid Repeaters can be powered from the Processor link or a wall-mount transformer.If powering from a wall-mount transformer, Pin 2 does not get connected. Wiring Diagrams—OS Wired Device Link �a������=iamil 1111 ........................... 111 MO al III QS Link ii III up to 99 device addresses u� QS Link Ild up to 99 device addresses Maximum 2 A combined current draw from processor when powering both links from the same power supply. Customer Assistance:RE C E IVE D www.lutron.com/support 6 1.844.LUTRONI (U.S.A./Canada) +44.(0)20.7680.4481 (Europe) 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ISSUE DATE: 06/01/2022 Processor Catalog #: HQP7-2 Page 7 of 7 H�EW RKS product specifications 3691127b 01.07.20 HomeWorks QSX Processor Wiring Diagrams—Link Power More current can be supplied by an additional power supply 4 Red Link 1(optional) Ip � \ � (3)Red Link 2(optional) 7■ 1 (2)Red+C PC Power (1)Black COM(Common) mon) UIf _ ii.A LI 9 2A 2A Max 2 A per link when using a separate power supply for each link Wiring Diagrams—QS Wired Device Link with Shades/Draperies(Controllable Window Solutions) 11I'_ in r ®\ Ratings:111 24V= 1A (4)MUX —120 V� 60 Hz riadmishibilr::-- (3)MUX (2)24 V= , co,�([1 11, Pi 11 ki.EE QS Link om 4 11 i 31e t6 l[ POI 0°ee [11—I[ E. HomeWorks QS wired devices eee eee q 11 QSPS-10PNL QS Smart Power Lutron,HomeWorks,Clear Connect,and Maestro are trademarks or Panel — — -- registered trademarks of Lutron Electronics Co.,Inc.in the US and/or HomeWorks QS other countries. wired devices All product names,logos,and brands are property of their respective owners. Customer Assistance:REC EivED www.lutron.com/support 7 1.844.LUTRONI (U.S.A./Canada) +44.(0)20.7680.4481 (Europe) 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 Repeater Catalog #: Refer to Lutron BOM Page 1 of 5 H�MEWQRKS.QS product specifications 369351c 04.27.16 HomeWorks® QS Hybrid Repeaters HomeWorks®QS Hybrid Repeaters add wireless Radio Frequency(RF)communication and extend the range of RF signals that are Hybrid Repeater sent between dimmers,switches,keypads, visor control receivers,shades/draperies,and other devices. Repeaters ensure error-free Repeater Status communication between system components and prevent interference from neighboring •;� •wed systems. PTe . . . . The first repeater connects to the HomeWorks®QS processor to provide RF LUTRON communication that extends up to 30 ft(9 m) Pone flmeseer67.4 in every direction. Up to four(4)total Hybrid I Repeaters can be used per link to extend the RF range for larger system applications. Each Repeater has an RF range of 30 ft(9 m) between repeater and devices or 60 ft(18 m) between repeaters, covering a total area of approximately 2500 sq ft(232 m2). Model Numbers Frequency HQR-REP-120 434 MHz HQK-REP 868 MHz HQM-REP 868 MHz Limited HQN-REP 865 MHz HQR-REP-120-BA 434 MHz(Brazil) HQQ-REP 434 MHz Limited Only available in White(WH). V PC HomeWorks®QS software will select the correct frequency/channel code for compatibility with your particular geographic region. www.lutron.com/help Lutron® 1 RECEIVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 Repeater Catalog #: Refer to Lutron BOM Page 2 of 5 H�MEWQRKS.QS product specifications 369351c 04.27.16 HomeWorks® QS Hybrid Repeaters Specifications Model Number HQR-REP-120; HQK-REP; HQM-REP; HQN-REP; HQR-REP-120-BA; HQQ-REP Power Hybrid Repeater: DC adapter: 9 V= 300 mA Link:24 V—50 mA DC adapter: Input: 100-240 Vim- 50/60 Hz 6.5 W Output:9 V= 300 mA Typical Power Hybrid Repeater:0.6 W Consumption Test conditions: one LED on, powered by a 9 V—adapter. Regulatory Approvals Hybrid Repeater: FCC, IC,COFETEL,CE,CCC,TRA, CTICK,ANATEL, IDA,SUPERTEL,SUTEL Environment Ambient operating temperature:32°F to 104°F(0°C to 40°C), 0%to 90%humidity, non-condensing. Indoor use only. Unit generates heat, maximum 4 BTU/hr Low-Voltage Wire Type Two pair-one pair 18 AWG(1.0 mm2),one pair 22 AWG to 18 AWG (0.5 mm2to 1.0 mm2)twisted shielded-NEC®Class 2/PELV cable. Required for connecting the first repeater to the processor and may be used to connect additional Hybrid Repeaters. Communications The first Hybrid Repeater communicates with the HomeWorks®QS processor on the RF wired link.Subsequent Repeaters may be wired on this link or may communicate over Radio Frequency(RF).All RF devices must be located within 30 ft(9 m)of a Repeater.All Repeaters must be within 60 ft(18 m)of another Repeater. ESD Protection Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2. Surge Protection Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits. Power Failure Power failure memory:should power be interrupted,the Repeater will return to its previous state when power is restored. Mounting Mount on a wall,ceiling,or level surface using the two#6(M3)screws provided. 'C Connections Hybrid Repeater: RS485 Warranty www.lutron.com/TechnicalDocumentLibrary/warranty.pdf Design Features • Test button-enters the RF repeater test mode. • RS485 port to connect to the HomeWorks® • Activate button-provides repeater activation QS RF link and to other repeaters through a within system. wired link(daisy-chain). 21 Lutron® Customer Assistance: 1.800.LUTRON1 RECEIVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ISSUE DATE: 06/01/2022 Repeater Catalog #: Refer to Lutron BOM Page 3 of 5 :5, FiRKS.QS �`�� product specifications 369351c 04.27.16 HomeWorks® QS Hybrid Repeaters Dimensions Measurements shown as: in(mm) Front View Side View hsee table below > — I I Hybrid Repeater Repeater Sam 51A 1/4) f11 Cammunica._n CI f (133 �� (6) Setup re.¢ np..em . • . • 2 3/4 (70) wmoN Mounting Holes �> I-c- 33/4(95) -).-I I 11/6 4-- 41/4(108) (27) Model Dimension HQR-REP-120,HQR-REP-120-BA, 6.25(158.8) HQQ-REP Mounting HQK-REP,HQM-REP,HQN-REP 3.13(79.4) Vertical Horizontal CeilingII um D� Ra #6(M3)screw I recommended (2 included) • III m- 121.111. AZIPIF www.lutron.com/help Lutron® 3 RE( EIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ■ ISSUE DATE: 06/01/2022 Repeater Catalog #: Refer to Lutron BOM Page 4 of 5 H�MEWC�RKS.QS product specifications 369351c 04.27.16 HomeWorks® QS Hybrid Repeaters Operation Hyur 1 t.„ i,, Repeater s E ij `°""'" •„,., Displays theStatu activationLDs status or „. test status of the Repeaters in • • Repeater Status the system. • I P •1 1 12 13 14 RF and wired LEDs Displays the Tx/Rx activity on i = Communication the RF and wired links. •I RF I Wired (Green=Tx; Orange=Rx) • Test and Activate Buttons Setup Press and hold to enter the Testl Activate system into Test mode or 1 • 1 • Activate mode. Test and Activate LEDs Flashes green to indicate that the system is in Test mode or Activate mode. Wired and RF Configuration Hybrid Repeater •xx rigi L 7 i -11.-1,30 ft(9 m) ''''.."7....."1 30 ft(9 m) 30 ft(9 m) ra 6 I maximum ` A„ t t maxi +< <, maxi i i ; RF I- 60 Link -I Wired Link(Daisy-chain) 60 ft(18 m) 1000 ft(305 m)maximum maximum IEC PELV/NEC.Class 2 cable Two pair-one pair 18 AWG (1.0 mm2),one pair 22 AWG to 18 AWG(0.5 mm2 to 1.0 mm2) twisted shielded. 4 I Luton® Customer Assistance: 1.800.LUTRON1 IE C E IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: ISSUE DATE: 06/01/2022 Repeater Catalog #: Refer to Lutron BOM Page 5 of 5 HkA WQRKS.QS �`�� product specifications 369351c 04.27.16 HomeWorks® QS Hybrid Repeaters Connections Top View RF range: To Repeater: 60ft(18m) To other devices: 30 ft(9 m) Bottom View Wired Link(Daisy Chain) maximum 1000 ft(305 m) >COM >24 V=Power Input MUX MUX ra Power Jack(to adapter) NOTE:Power must be provided by a IEC PELV/NEC®Class 2 9 V—adapter or 24 V—power on the O O HomeWorks®QS processor link. www.Iutron.com/help Lutron® 5 RECEIVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: TPS ISSUE DATE: 06/01/2022 Catalog #: TK-TTLP-1S240-FL (Breaker Panels) Page 1 of 9 Application Note#97 Overview Lightning strikes may cause permanent damage to household electrical equipment, including LutronRSystem components. Lightning strike-damaged equipment is not covered by the LutronR Warranty and should be reported to the homeowner's insurance company. All LutronRproducts are designed with integrated surge suppression devices. (Lutron follows the IEEE C62.41-1991 recommended practice on Surge Voltages in Low Voltage AC Power Circuits.) These integrated suppression devices are effective for preventing damage in most installations. Despite this fact, high-risk homes that are located in lightning-prone locations may experience surge levels that are capable of damaging LutronRdevices, particularly in the case of a direct lightning strike on the property. (For additional information on lightning-prone areas of the U.S. and abroad, see the maps at the end of this application note.)Although this type of damage is typically covered by the homeowner's insurance,there is inconvenience involved in getting equipment replaced and/or having non-functional products. Many installers and homeowners are interested in adding additional protection hardware to their systems to minimize the risk of this sort of disruption.This application note was written to address these interests. The devices recommended in this document are some of the most rugged and cost-effective protection devices available.Although installing these devices will provide an added degree of protection, in the most extreme circumstances damage is still a possibility.The likelihood of damage occurring will be greatly reduced when surge protection is used.This application note covers surge protection of low voltage links and the high voltage side of the installation with use of AC panel mount surge suppression with filtering.This may require additional solutions including: lightning rods, grounding methods, and local (near to a component)surge suppression, etc. High voltage surge suppression requires expertise(consider consultants if this is not internal to your organization) and up-front planning/design. Our customers often ask why Lutron doesn't integrate the surge protection provided by the external devices directly into our products.The primary reason is that over time(many surges)or given a surge with sufficient energy the suppression devices can/will fail. When they fail they tend to fail "shorted"to ground.This failure mode is "good" in the respect that it continues to protect the LutronRequipment, although communications on the link will no longer work. External surge protection devices can be replaced easily, at low cost, with no reprogramming. If the devices were built into the LutronRproduct,the entire product would have to be replaced.We may have delayed the product replacement but we haven't prevented it. Other benefits of external protection are: • For maximum protection, it is best to have surge energy shunted away before it gets into the LutronR llU� equipment as •The physical space required is impractical to implement in many products• Not every customer needs to "pay" (in terms of size or cost)for this protection (for example, per the lightning strike maps, someone in the Northwest with a single building install, no integration connected,...) LUTRON® 2 www.lutron.cRE C "IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: TPS ISSUE DATE: 06/01/2022 Catalog #: TK-TTLP-1S240-FL (Breaker Panels) Page 2 of 9 Application Note#97 Recommendations Installation Based Recommendations • Protect all electrical breaker panels feeding dimmers, processors, and dimming panels. A panel mounted surge suppression unit with enhanced filtering will protect equipment from catastrophic events, clean the power, and suppress internally generated transients that can lockup electronics, necessitate reprogramming of controls, and gradually deteriorate sensitive electronics. See Section 3.4.3, IEEE Std.1100-2005. • Protect all RS-232 ports with permanently connected third party equipment (typically other processors that are part of integration systems). While RS-232 communication wire runs are themselves short, all of the equipment and wire runs that are connected to the third-party equipment provide an electrical path to conduct damaging surges. Damage most often occurs because the ground referencing between the two systems can become separated during a surge. This creates high voltages that damage the RS-232 ports, and is the most common type of port failure. • Protect any link or bus that travels between buildings regardless of geographical location. Again damage may occur because the ground referencing between buildings can become separated during a lightning strike. Lutron recommends using fiber optic communication between buildings. Using fiber cable breaks the electrical connection (by using light rather than current carrying conductors)and will minimize damage if one building gets struck. Refer to "RS-485 Communication Using Fiber Optics Modem FAQ" on the HomeWorksRResource Website. • Protect Links/Busses that have wire runs over 500 ft(152.4 m) long even if they are contained within a single building. A long wire run is susceptible to high levels of capacitively coupled surge energy as it travels alongside other wires and through the structure and mechanicals of the building. Geographical Based Recommendations Refer to the lightning strike maps at the end of this document. • Protect all breaker panels feeding lighting system from internal and external surges. • Protect 120 V— outputs from dimming modules which go outside(such as to landscape lighting) in areas that are determined to be at high risk, such as those at high elevations, and those in close proximity to water. • Protect all links/busses for installations in orange and red areas. In the US, for example, this would include Florida, the Southeast, and portions of the Midwest. [fib • Protect all links/busses for installations in areas that are determined to be at high risk, such as 119Rll1 those at high elevations, and those in close proximity to water. as Note: The lightning strike maps in this application note are best viewed in color. Please view on a computer or print out in color. LUTRON® 3 www.lutron.cRE C "f VE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: TPS ISSUE DATE: 06/01/2022 Catalog #: TK-TTLP-1S240-FL (Breaker Panels) Page 3 of 9 Application Note#97 Surge Protection Equipment The following surge protection equipment may be used to protect lighting panels and all dimming controls.The following suppression units will protect the electrical system from external transients entering the system through the power lines. The filtering part of the units will clean the power, and suppress internally generated transients that can lockup electronics, necessitate reprogramming of controls, and gradually deteriorate sensitive electronics. See Section 3.4.3, IEEE Std.1100-2005. Breaker Panel Protection 1. Total Protection Solutions Breaker - Panel Protection Manufacturer: Total Protection Solutions, LLC. Model Number: TK-TTLP-1 S240-FL Website: www.TPSsurge.com RS-232 Surge Protection The following surge protection equipment may be used to protect RS-232 ports 1. Total Protection Solutions RS-232 Surge Protection r Manufacturer:Total Protection Solutions, LLC Model Number:TK-CT2-DB9-DIN2 a 67 Website: www.TPSsurge.com as LUTRON® 4 www.lutron.cRE C "IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: TPS ISSUE DATE: 06/01/2022 Catalog #: TK-TTLP-1S240-FL (Breaker Panels) Page 4 of 9 Application Note#97 Surge Protection Equipment (continued) RS-485 Protection The surge protection equipment listed below may be used to protect the RS-485 links. 1. Total Protection Solutions RS-485 Surge Protection Manufacturer: Total Protection Solutions, LLC. � Model Number: TK-CT2-24LIT24 f R o Model Number: TK CT2 24LIT12 -Mu / o m Model Number: TK-CT2-24LIT4 ° a Website: www.TPSsurge.com TK-CT2-24LIT24(12 pair) TK-CT2-24LIT12(6 pair) TK-CT2-24LIT4(2 pair) Note:24-Terminal(12-pair), 12-terminal(6-pair),and 4-terminal(2-pair)devices are available.Choose model based on the number of RS-485 links and H48/D48 dimming busses to be protected.Same unit can be used for both dimming busses and links. H48/D48 dimming interface Protection (HomeWorksRand HomeWorksRQS only) The surge protection equipment listed below may be used to protect the H48/D48 dimming interface. 1.Total Protection Solutions H48/D48 Surge Protection iw - Manufacturer: Total Protection Solutions, LLC. Model Number: TK-CT2-24LIT24 s/ o Model Number: TK-CT2-24LIT12 - r `ate 141 TK-CT2-24LIT24(12 pair) TK-CT2-24LIT12(6 pair) FO Website: www.TPSsurge.com Note: 24-Terminal(12-pair)and 12-terminal(6-pair)devices are available.Choose model based on the number of RS-485 links and H48/D48 dimming busses to be protected.Same unit can be used for both dimming busses and links. LUTRON® 5 www.lutron.cRE C "IVE D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: TPS ISSUE DATE: 06/01/2022 Catalog #: TK-TTLP-1S240-FL (Breaker Panels) Page 5 of 9 Application Note#97 Line Voltage Protection Breaker Panel Equipment Placement- Using Total Protection Solutions Example: Connection to breaker panel. Locate and install one TK-TTLP-1 S240-FL at each breaker panel feeding HomeworksRprocessors, dimming modules and remote module interface. 120 V- Power/ Circuits s Protect Power to Equipment Breaker / 'tii=•• Panel 1< ' 1 Dimming ' Panel Remote Module o • Interface TK-TTLP-1S240-FL HomeWorks'— �- -4 Processor f }rnrrll' Breaker Panel Wiring Detail - Using Total Protection Solutions Installation Based Recommendations Install on all breaker panels powering LutronRequipment. 120/240 V- split phase breaker panel Install white and green wires llU� to the Neutral/ Foi ground bus i Install two black ! i wires to a 2 Pole111 W 20Aor30A — " Circuit Breaker i TK-TTLP-1S240-FL LUTRON® 6 www.lutron.cRE C E IV "'D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: TPS ISSUE DATE: 06/01/2022 Catalog #: TK-TTLP-1S240-FL (Breaker Panels) Page 6 of 9 Application Note#97 Line Voltage Protection (continued) Dimming Module Equipment Placement- Using Total Protection Solutions Example: Connection to 120 V— landscape lighting Protect Dimming Modules , r May require an additional enclosure g To landscape to house surge protections I _• lighting. :� ! TK-LT120-20A-DIN2 i Note:Surge suppressor must be i� grounded to a common point ground �`t !�— A. which is tied to the AC ground of the it processor. Dimming Module Wiring Detail - Using Total Protection Solutions Total Protection Solutions Installation Based Recommendations TK-LT120-20A-DIN2 From DimmingHot Hot To Landscape Modules Neutral I '- Neutral Lighting i3 b Ground Ground va LUTRON® 7 www.lutron.cRE C E IV "'D 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: TPS ISSUE DATE: 06/01/2022 Catalog #: TK-TTLP-1S240-FL (Breaker Panels) Page 7 of 9 Application Note#97 HomeWorks® QS (continued) RS-485 Equipment Placement- Using Total Protection Solutions Example: HomeWorks systems with low-voltage wire runs outside or between buildings using Total Protection Solutions o / \ HomeWorksRQS Processor TK-CT2-24LIT24 ME TT Keypad GRAFIC EyeR H QS unit TK-CT2-24LIT24 ► QS Link Hybrid Repeater T11T I ITK-CT2-24LIT24 Example: System components that are wired greater than 500 ft(152.4 m)from the processor: Protect Processor and Interface UKeypad & B .. ; B g 2 Lieja g e -�- - - FO 2 B B 2 d e g g lo n 0 Module HomeWorksRQS Wiring distance greater Interface Processor than 500 ft(152.4 m) 11 TK-CT2-24LIT24 TK-CT2-24LIT4 LUTRON® to www.lutron.cRECEIVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: TPS ISSUE DATE: 06/01/2022 Catalog #: TK-TTLP-1S240-FL (Breaker Panels) Page 8 of 9 Application Note#97 HomeWorks® QS (continued) RS-485 Component Wiring Detail - Using Total Protection Solutions Total Protection Solutions TK-CT2-24LIT24 with Inter-Processor Link, Module Interface Link, GRAFIK Eye. Link, Shade Interface or Dimmer Interface not powered by Processor 1 2 3 4 LutronR TK-CT2-24LIT24 Processor ' m Link or ;�_ To a TK-CT2-24LIT24, CommonModule Interface I __f N/C rface HomeWorksR Field wiring Device V MUX EarthA. MUX J Ground' U Total Protection Solutions TK-CT2-24LIT24 with Keypad Link, Hybrid Repeater Link 1 2 3 4 LutronR or TK-CT2-24LIT24 Processor Link or To a TK-CT2-24LIT24, Module Common Keypads or Hybrid Interface +24 VZ i Field wiring Repeaters -it �� — � MUX MUX Earth Ground'. NOTES: a = 1 A good connection must be made between the TK-CT2-24LIT24 and earth Wa ground.This can be done with the terminal post on the top of the unit 2 Connect+24 V terminal only if the keypads or Hybrid Repeater is being powered form the link and not from an external power supply or local transformer. 3 The TK-CT2-24LIT24,TK-CT2-24LIT12 and the TK-CT2-24LIT4 can be used on both dimming busses and RS-485 links. RI POI LUTRON® 11 www.lutron.cREC iVED 08/18/2022 ASPEN BUILDING DEPARTMENT PROJECT: Little Nell Spa & Gym TYPE: TPS ISSUE DATE: 06/01/2022 Catalog #: TK-TTLP-1S240-FL (Breaker Panels) Page 9 of 9 Application Note#97 Contact Information Total Protection Solutions, LLC Parts List PO Box 3760 Winter Park, FL 32790-3760 Total Protection Solutions, LLC Phone:+1.800.448.4087 Parts List Fax: +1.407.951.5887 Breaker Panel Protection Web:www.TPSsurge.com TK-TTLP-15240-FL Unlimited Amperage Sales Email: Maureen@TPSsurge.com Technical Support: Bob@TPSsurge.com Dimming Module Protection TK-LT120-20A-DIN2 Max 20 A Circuit TK-LT120-15A-DIN2 Max 15 A Circuit RS232 Protection TK-CT2-DB9-DIN2 RS232 DB9 Connection RS-485&H48/D48 Dimmer Interface Protection TK-CT2-24LIT24 24 Wire(12 pair) TK-CT2-24LIT12 12 Wire(6 pair) TK-CT2-24LIT4 4 Wire(2 pair) Lutron,HomeWorks QS,HomeWorks,RadioRA are registered trademarks and RadioRA 2 is a trademark of Lutron Electronics Co.,Inc. Lutron Contact Numbers WORLD HEADQUARTERS EUROPEAN HEADQUARTERS ASIAN HEADQUARTERS USA United Kingdom Singapore Lutron Electronics Co.,Inc. Lutron EA Ltd. Lutron GL Ltd. 7200 Suter Road 6 Sovereign Close 15 Hoe Chiang Road Coopersburg,PA 18036-1299 London,E1W 3JF United Kingdom #07-03,Tower 15 TEL:+1.610.282.3800 TEL:+44.(0)20.7702.0657 Singapore 089316 FAX:+1.610.282.1243 FAX:+44.(0)20.7480.6899 TEL:+65.6220.4666 Toll-Free: 1.888.LUTRON1 FREEPHONE(UK):0800.282.107 FAX:+65.6220.4333 D b Technical Support: 1.800.523.9466 Technical Support:+44. Technical Support:800.120.4491 intsales@lutron.com (0)20.7680.4481 FDI lutronlondon@lutron.com lutronsea@lutron.com h America Asia Technical Hotlines North&Sout Technical Hotlines Northern China: 10.800.712.1536 Southern China: 10.800.120.1536 USA,Canada,Caribbean: Hong Kong:800.901.849 USA, 6 Indonesia:001.803.011.3994 1.800Japan:+81.3.5575.8411 Mexico: +1.888.235.2910 Macau:0800. Taiwan:00.801.137.737 Central/South America: Thailand:001.800.120.665853 +1.610.282.6701 Other Countries:+65.6220.4666 Lutron LUTRON® 17 7200 SutertRoads Co.,Inc. RECEIVED Coopersburg,PA 18036-1299 U.S.A. R �� P/N 048097 Rev.G 12/2014 08/18/2022 ASPEN BUILDING DEPARTMENT