HomeMy WebLinkAboutFile Documents.1225 Alta Vista Dr.0086-2024-BROF (5) CITY OF ASPEN • ••*• I • Eno ork ,,,,� 1 Field Plan Set Must Be Printed In Color �`►►i �
PERMIT N0. __ �. ...-_, , ��� /
0086-2024-BROF
(r ` } ♦`� e' ICC
•
EVALUMION
OWNER OAK LODGE LLC �'t _ .��.��• �� I EiTL cr CITY OF
ADDRESS 330 LAKE AVE - • .440
ASPEN
Toilet .11
PARCEL ID 273512128001 >i�z:. s w
wwcc•es.orq I(800)423-6587 I(562)699-0543 A Subsidiary of the International Code Councile These plans must be kept at the
w.i
building site or inspection
ICC-ES Evaluation Report Reissued December2021 delays may occur.Construction
r
APPLICATION ACCEPTED DATE: 2024-10-02 PERMIT NUMBER: 0086-2024-BROF IPW a ESR-3267 This report is subject to renewal December 2023. Shall Conform t0 these plans.All
III e , r 7j DIVISION:07 00 00—THERMAL AND MOISTURE 3.1.2 Three-tab Shingles and Five-tab Shingles:Three- changes shall be approved by
` PROTECTION lab and five-tab shingles are composed of a single layer of the building official.
�� , Section:073113—Asphalt Shingles reinforcing felt,impregnated and coated with surfacing
COMMUNITY DEVELOPMENT DEPARTMENT 1 I�j�/� - material on the weather side and with a surfacing release
;1',/� . REPORT HOLDER: agent on the underside.
BUILDING PERMIT COVERSHEET ��� / +* 3.1.3 Laminated Shingles: Laminated shingles are SEPARATE PERMITS ARE
CITVOFASPEN .• 7 GAF composed of multiple thicknesses or coated and surfaced REQUIRED FOR ELECTRICAL,
- -~0 La ker A r e 'Z1k b J • EVALUATION SUBJECT: reinforcing fell cut and bonded together in atac:different
r patterns.The weather side is surfaced with surfacingmaterial on PLUMBING,MECHANICAL,OR
PROPERTY INFORMATION • - - s - GAF SHINGLE ROOF COVERING SYSTEMS gent on the'underside.he n side and with a surfacing release FIRE SPRINKLER WORK
• 1.0 EVALUATION SCOPE 3.1.4 Hip and Ridge Cap Shingles:Hip and edge cap
ADDRESS: 330 LAKE AVE UNIT: 1,
- shingles consist of reinforcing felt,impregnated and coated SMOKE ALARMS AND
PARCEL ID: 273512128001 LEGAL DESCRIPTION: HOME LOT SPLIT - — - Compliance with the following cedes: CARBON MONOXIDE
OWNER: OAK LODGE LLC with asphalt on both sides and surfaced with surfacing
•2018,2015,2012,2009 and 2006 Infemational Building material on the weather side and a surfacing release agent DETECTORS REQUIRED
PERMIT CONTRACTOR: Code®(IBC) oa the back side for use in covering hips and edges.See
flki -. -.1:
■2018, 2015, 2012, 2009 and 2006 Infemational Table 2 for product sizes,exposure to the weather and THROUGHOUT DWELLING
} - 1 manufacturing locations.See also Figure 2.
- _ I • - Residential Code®(IRC) UNIT PER CITY OF ASPEN
- Propertiesevalualed: 3.1.4.1 Royal Sovereign®Ritlge Cap Shingles:These MUNICIPAL CODE 8.15
- , ridge cap shingles are fieldcut from Royal Sovereign®
lb 1 ♦ ilip
■Weather resistance three-tab strip shingles.The field-cut ridge cap shingles are
DESCRIPTION OF WORK Remove and properly dispose of existing cedar shingles.Fabricate and install 24 ga.pre-finished flashing. M compatible with any of the GAF shingles recognized in this
•Fire Gasification
Furnish and install full coverage high temp ice and water shield.Furnish and install architectural asphalt report.
•Wind resistance
shingles.Furnish and install all roof penetration flashing.Install 55 pre-finished snow guards.Properly dispose of r•l t 44gs 3.1.4.2 Z°Ridge Ridge Cap Shingles:These shingles are
all debris. id
l �y 2.0 USE strips that are scored for separation into four ridge cap It should be known that this review Shall
+JP • t t i shingles.
e GAF asphalt shingles describes in this report ar not relieve the applicant of their
• alternatives to asphalt shingles complying with IBC Section 3.1.4.3 Seal-A-Ridgec Ridge Cap shingles, seal-A- responsibility to comply with the
1507.2 and IRC Section R905.2 and are Class A roof Ridge'Protective Ridge Cap Shingles,Seal-A-Ridges requirements of the City Aspen of
Snow stops required at all locations verings when installed as described in this report. A AS SBS-Modified IR Ridge Cap Shingles, and Seal-A-
where roofs could shed snow onto t _ 3.0 DE Ridge° ArmorShield® SBS-Modified IR Ridge Cap Municipal Code.Pursuant to
Shingles:These shingles are steps that are scored for
USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? Yes walkways,stairs,alleys,decks,exits, r• Sec.26.104.050,any permit or approval
y y 3.1 Shingles: ridge cap shin iris.Seal-A-Rid
utilities and meters,emergency escape ♦ 1 O/`- separation into threeg fie®
and rescue opening window wells,or F 3.1.1 General:The GAF asphalt shingles comply with the A R:dso i Ridge cap Shingles are also labeled as seal- issued in error or otherwise not in
rl ICC-ES Acceptance Criteria for Alternative Asphalt Roofing A-Ridge°AS SBS-Modified IR Ridge Cap Shingles. conformity with the requirements of this
CLASS OF WORK Residential FIRE SPRINKLER TYPE adjacent properties-Ordinance 1, _ �� • Shingles (AC438), and have been qualified for wind 3.1.4.4 Ridglass®Premium Ridge Cap Shingles:These Title,shall be void.Similarly,any permit
2023. •Mir • , . resistance as noted in Section 4.3 and Table 1.The shingles shingles are individual,thick,ultra-high-profile ridge cap or approval issued in reliance upon or
available as three-tab,five-tab and laminated asphalt shingles available in two widths.
iT- •1` WTI, ' ow shingle roof coverings.See Table 1 and Figure 1 for as a result of,a materially false
REQUIRED SPECIAL ♦- e recognized oduct names and classifications, shingle 3.1.4.5 Timbertea® Premium Ridge Cap Shingles:
g pr g statement or representation made in
BUILDING TYPE(IRC) One family INSPECTIONS - r .• - types, manufacturing locations, overall dimensions, These shingles are double layer stops that are scored for
maximum exposure to the weather and fastening details. separation into three ridge cap shingles. the process of obtaining the permit or
The shingles are self-sealing by means of adhesive strips 3.1.4.6 TimberCresr, Premium SBS-Modified Ridge development approval shall,likewise,
located on either the weather side or the underside.See Cap Shingles: These shingles are individual, thick, be void.Any person having received a
CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE Figure 1 for dimensions,nailing locations and adhesive strip ultra-high profile ridge cap shingles with a bulinose leading void or voidable permit or approval
location for field shingles. edge available in two widths.See Figure 2.• shall not be relieved from having to
WORK CHANGES BUILDING comply with all applicable terms and
OCCUPANCY GROUP(IBC) R-2 ICC.ES Evallowton Rem are nal iubea-,^,m°...rv..,.^r,^s°emere,,,,,,,,,,,,,x..°,obuies rug,rnlc.m,we,.,..e.tun-are gl,to Pr,oM,�,m
FOOTPRINT? °e,,,,,r„m,^,A,n ea of the 11,0,p,„fi,,i ,e There;,^^„n„°^rib,,rr.:-,,mbo,Service.uc..,,�,^rmy".... •"�' conditions of this Title and the City shall
not be estopped from fully enforcing
CcPNSh:02021 ICC Evaluation service,LLC.All,acu reserves. Pepe,or 12 same.
CODE EDITIONS 20211BC TOTAL SPA SQ.FT.
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT.
HISTORIC PROPERTY? Yes TOTAL POOL SQ.FT.
.............. rEWE a2/2024 J
FIRE SPRINKLER EXISTING? \ Asphalt Roof Shingles FppCUINVANCE
\\ linzhid
Work on heat tape is not permitted under this scope.
If any existing heat tape is touched or new heat tape
Existing PSU 30 High Temp Ice&Water Shield is proposed, it will be subject to REMP payment and
Plywood&Fascia 24 ga.pre-finished metal flashing heat tape control requirements and will require a
sub-electrical permit.
Reach out to your permit reviewer with questions.
Final Roof Inspection
REQUIRED
om
0D o 7
Once roof work is complete, you FA .N m
Mid-Roof Inspection must request a final roof )>Z N
REQUIRED inspection. z 0
After your roof permit is issued, Inspectors will inspect snow
and you have started work, you guards and heat tape (if
must request a mid-roof applicable).
inspection.
NOTE If there is heat tape NOTE: You many not substitute roofing components/products that stray
Inspectors will verify your Class present, a final roof inspection from the approved and issued ESR/QAI report without Building
A assembly on site. cannot be requested until the department approval. MID-ROOF AND FINAL
sub electrical permit is applied Class A assemblies are tested and listed with the specific roof products ROOF INSPECTIONS
You will request inspection for as both final inspections will called out in the associated documentation. Installers shall follow all REQUIRED TO RECEIVE A
directly on SalesForce. occur simultaneously. manufacturer's installation instructions for Class A roof assembly. LETTER OF
COMPLETENESS