Loading...
HomeMy WebLinkAboutFile Documents.1227 Alta Vista Dr.0074-2024-BROF (2) City of Aspen Residential Projects RREMP Calculation Version 1.7(6/18/2024) Complete and submit this page for Residential projects. Project Address: 1227 ALTA VISTA DR Permit Number: 0074-2024-BROF Relevant Sheet Number(s): List all drawing sheets containing REMP information. Use this tab for Residential projects(Group R2&R3,3 stories or less)or for residential portions of mixed used buildings. 1.Enter all new exterior energy uses on the site It existing energy uses are being replaced or relocated enter those uses in this tab as new and also enter them in the REMP-Existing tab under'existing to be moved.'To receive credit for existing to be replaced or relocated energy uses,use the REMP-Existing tab.Existing to remain exterior energy uses must be entered in the REMP-existing tab. Exempt energy uses:The following energy uses may be entered as'exempt'but you must demonstrate how this exemption is met(subject to approval by the building official). In-Slab Snowmelt and Outdoor Electric Heat Mats: 1.A nine square foot portion of emergency escape and rescue window wells is exempt 2.Accessible routes as defined by IBC section 1104.1 and 1104.2 and limited to 48"in width is exempt. Outdoor spa: 1.A maximum of(1)portable spa per property with a water surface area of not more than 64 square Heat tape including roof end gutter deicing systems and exterior piping: 1.Up to 1000 watts are exempt. 2.IMPORTANT::Enter all existing to remain residential exterior energy uses on the site in the RREMP-Existing tab so they can be included in the Annual BTU Exterior a Enteral)new interior fireplaces. 4.Use the appropriate tabs to enter renewable energy credits.Solar hot water system square footage is entered here. 5.Energy offset amounts are totaled here,along wdh total credits.Credit received from existing to be removed or replaced systems as calculated in the REMP-Exiling tab is accounted for here.d you made a payment in lieu earlier in this project,enter that amount in"amont previously paid." 1.Exterior Energy Use Calculations Annual BTU Energy Use Offset required Application Efficiency Budget %Offset PV kW I Payment In lieu 1.In-Slab Snowmek I 0 I sq.ft. Calculated-Total area of proposed in-slab snowmett and heat source efficiency. (1a)Exempt In-Slab Snowmen: 0 sq.ft. Enter area of exempt in-slab snowmelt COA to verify. (ib)Non-Exempt In-Slab Gas Snovnnelt 0 sq.ft. 92.0% - 100% I 0.00 I to.0o I Enter total area of in-slab snowmeh less the exempt area. (ic)Non-Exempt In-Slab Electric Snowmelt: 0 sq.ft. I 100.0% I - 100% I 0.00 I to.0o I Enter total area of in-slab snowmeh less the exempt area. 2.Outdoor Electric Heat Mats: I 0 I Watts Calculated-Total watts of proposed heat mats. (2a)Exempt Heat Mats: 0 Watts Enter watts of exempt electrical heat mats COA to verify. (2b)Non-Exempt Heat Mats: 0 Watts I 100.0% I - 100% I 0.00 I to.0o I Enter total wattage of heat mats less the exempt wattage. 3.Outdoor Spa: I 0 I sq.ft. Calculated-Total area of proposed spa and heat source efficiency. (3a)Exempt Spa: 0 sq.ft. Enter total area of exempt spa.COA to verify. (3b)Non-Exempt Spa: 0 sq.ft. 92.0% - 100% I 0.0o 00.50 I Enter total area of spa(water surface) 4.Outdoor Pool: 0 sq.ft. 92.0% - 100% I o.00 $o.00 I Enter total area of proposed pool(water surface). 5.Heat Tape: I 5740 I Watts Calculated-Total watts of proposed heat tape/trace. (5a)Exempt Heat Tape: 1,000 Watts Enter watts of exempt electrical heat tape/trace(fkw max)COA to verify. (5b)Non-Exempt Heat Tape: 4,740 Watts I 100.0% I 24,340,184 100% I 4.76 I $15,456.35 I Enter total wattage of heat tape/trace less the exempt wattage. 6.Outdoor Electric Heaters: 0 Watts I 100.0% I - 100% I o.00 I $o.00 I Enter watts ofelectricaly powered exterior heaters. 7.Outdoor Gas Fireplaces 8 Firepits: Btu/hr - 100% I 0.0o I to.0o I Enter total emplace&tirepit BTUs(input BTUs). Proposed Exterior Annual Energy Use Budget: 24,340,184 Existing to Remain Exterior Annual Energy Use Budget: - Total Exterior Annual Energy Use Budget: 24,340,184 Cell will tum red if exterior annual energy use budget of 200,000,000 btu is exceeded:reduce proposes Excludes exempt uses. Exterior Energy RREMP Payment Total: I 4.76 $15,456.35 I 2.Interior Energy Use Calculations Offset required Application Annual Use BTU %Offset PV kW Payment in lieu 1.Indoor Gas Fireplaces: 0 Btulhr - I 100% 0.00 $0.00 Enter total fireplace BTUs(input BTUs).Direct vent units only. Interior Energy RREMP Payment Total I 0.00 I $0.00 3.On-site Renewable Credits Offset Applied Supplemental Energy Sources(options for on-line offset of projected energy consumption) equiv PV kW I Credit applied 1.GSHP(Ground Source Heat Pumpl Btu I 0 I 0.00 $0.00 From GSHP Btu capacity on GSHP tab.Complete and submit that sheet 2.ASHP(Air Source Heat Pump) Btu I 0 I I 0.00 I $0.00 From ASHP Btu capacity on ASHP tab.Complete and submit that sheet 3.SHW(Solar Hot Water) sq.H. I 0 I I 0.00 I $0.00 Use installed panel area. 4.PV(to be installed on she) kW I 0.00 I I 0.00 I $0.00 From PV Generation tab.Complete and submit that sheet 5.Alternative Renewable Energy Source 0.00 I $0.00 From Alt Energy Source tab.Complete and submit that sheet Supplemental Energy Credit Total: I 0.00 I $0.00 I 4.Total RREMP Payment: PV kW Payment in lieu Total Exterior and Interior Energy(Sections 1 8 2 above): 4.76 515,456.35 Total Onalte Mitigation(Section 3 above): 0.00 $0.00 Prorated Credit for"Existing to be Removed": $0.00 Prepared by: Amount previously paid on this project: $0.00 email Total RREMP Due: $15,456.35 phone COA reviewer: Llnrh/D I_