Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.315 E Hyman Ave.0011-2023-BCOM (6)
Change Narrative TO: Nick Thompson DATE: 9/15/2023 FROM: Rebecca Stone PROJECT Gravity Haus Aspen NAME: SUBJECT: Change Narrative PROJECT#: 123034.00 CC: Gravity Haus:Grady Huff,Alicia FILE#: Deters;OZ Architecture:Chris Vandall,Suzanne Stawiarski ARCHITECTURAL A0.1 COVER PAGE • none A0.2 SHEET INDEX • none A0.3 SPECIFICATIONS • Glazing performance note added A0.4.1 CODE PLAN • Code occupancy calculation clarification • updated restaurant exiting A0.4.1A CODE PLAN • Code occupancy clarification A0.4.2 CODE PLAN • None A0.4.3 FIRE SEPARATION RECEIVED • None 09/18/2023 A0.4.4 ACCESSIBILITY PLAN ASPEN • Laundry room accessibility graphics added to show cor eo Nu DEPARTMENT A0.4.5 ACCESSIBILITY PLAN • None A0.4.6 ACCESSIBILITY DETAILS • None A0.4.7 ACCESSIBILITY DETAILS • None A0.6.2 UL ASSEMBLIES • Nomenclature changes from column to floor. 9/15/2023 3003 LARIMER ST (303)861-5704 Page 1 of 8 DENVER,CO 80205 OZARCH.COM • A.07.1 WALL, FLOOR, & ROOF ASSEMBLIES • Vapor retarder location updated. A.07.2 FIREPROOFING • None A0.8.1 DOOR SCHEDULE • Door schedule has been updated • Egress doors with panic hardware clarified • Exterior door threshold detail has been provided. A0.8.2 GLAZING SCHEDULES • None A0.8.3 HARDWARE SPECIFICATION • Hardware specification Sheet updated. • Glazing specification moved to this sheet A0.11.0 CREMP PLAN • None A0.23 FLOOR AREAS • None A0.26 Tier 1 & 2 PLANS • Sheet updated A0.27 Leasable Plans • Sheet added for BD A1.1.0.1 SITE PLAN RECEIVE[ • None 09/18/2023 AE1.1.1 BASEMENT EXISTING PLAN ASPEN • None BUILDING DEPARTMENT AD1.1.1 BASEMENT DEMO PLAN • None A1.1.1 ENLARGED BASEMENT RENO PLANS • None AE1.1.2 LOWER LEVEL EXISTING PLAN • None AD1.1.2 LOWER LEVEL DEMOLITION PLAN • none 9/15/2023 Page 2 of 8 A1.1.2.1 LOWER LEVEL RENO PLAN • Additional doors added to be replaced. A1.1.2.2 LOWER LEVEL RENO PLAN • None A1.1.2.3 LOWER LEVEL RENO PLAN • None AE.1.1.3 UPPER LEVEL EXISTING PLAN • None AD.1.1.3 UPPER LEVEL DEMO PLAN • None A1.1.3.1 UPPER LEVEL RENO PLAN • Door added A1.1.3.2 UPPER LEVEL RENO PLAN • None AE.1.1.4 ROOF EXISTING PLAN • None A1.1.4.1 ROOF RENO PLAN • None A1.1.4.2 ROOF DRAINAGE PLAN • None A1.2.1 BASEMENT RCP l'r • None A1.2.2 LOWER LEVEL RCP 09/18/2023 • None ASPEN A1.2.3 UPPER LEVEL RCP BUILDING DEPARTMENT • None A2.1 EXTERIOR ELEVATIONS • None A2.2 EXTERIOR ELEVATIONS • None A2.3 EXTERIOR ELEVATIONS • None 9/15/2023 Page 3 of 8 A2.4 EXTERIOR ELEVATIONS • None A2.5 EXTERIOR ELEVATIONS • None A2.6 EXTERIOR ELEVATIONS • None A2.7 EXTERIOR ELEVATIONS • None A2.8 EXTERIOR ELEVATIONS • None A2.9 BUILDING SECTIONS • None A2.10 BUILDING SECTIONS • None A2.11 BUILDING SECTIONS • None A4.1 DETAILS • Roof details updated. • Detail 17 added. • Detail 15 revised A4.2 DETAILS • None , j. ; , �__,r A4.3 DETAILS 09/18/2023 • None ASPEN A4.4 DETAILS BUILDING DEPARTMENT • None INTERIOR DESIGN ID0.1 COVER • None ID0.10.1 FINISH SCHEDULE • None ID0.10.2 FINISH SCHEDULE 9/15/2023 Page 4 of 8 • None ID1.1.1 BASEMENT RENO PLAN • None ID1.1.2 LOWER LEVEL RENO PLAN • None ID1.1.3 UPPER LEVEL RENO PLAN • None ID1.2.1 BASEMENT RCP • None ID1.2.2 LOWER LEVEL RCP • None ID1.2.3 UPPER LEVEL RCP • None ID1.3.1 BASEMENT FINISH PLAN • None ID1.3.2 LOWER LEVEL FINISH PLAN • None ID1.3.3 UPPER LEVEL FINISH PLAN • None ID1.4.2 LOWER LEVEL FURNITURE PLAN • None ID1.4.3 UPPER LEVEL FURNITURE PLAN • None 09/18/2023 ID3.1 INTERIOR ELEVATIONS ASPEN • None BUILDING DEPARTMENT ID3.2 INTERIOR ELEVATIONS • None ID3.3 INTERIOR ELEVATIONS • None ID3.4 INTERIOR ELEVATIONS • None ID3.5 INTERIOR ELEVATIONS • None 9/15/2023 Page 5 of 8 ID3.6 INTERIOR ELEVATIONS • None ID3.7 INTERIOR ELEVATIONS • None ID3.8 INTERIOR ELEVATIONS • None ID3.9 INTERIOR ELEVATIONS • None ID4.1 INTERIOR DETAILS • None STRUCTURAL SO STRUCTURAL GENERAL NOTES Revised Special Inspections-2015, Item 1 B. S1 FOUNDATION PLAN None S2 MAIN LEVEL FRAMING PLAN None S3 UPPER LEVEL FRAMING PLAN I None S4 ROOF FRAMING PLAN None S5 SECTIONS 09/18/2023 • None ASPEN S6 SECTIONS BUILDING DEPARTMENT • None S7 DETENTION TANK • Revised shoring note to include "temporary." MECHANICAL AND PLUMBING M0.02 • None M0.03 9/15/2023 Page 6 of 8 • None M0.04 • None M0.05 • None M1.01 • Added fire dampers at wall penetrations of the mechanical room M 1.02 • None M 1.03 • Additional information has been provided. To be clear the dryer exhaust penetrates the abandoned elevator shaft through the side wall overrun. M 1.04 • Additional information has been provided. To be clear the dryer exhaust penetrates the abandoned elevator shaft through the side wall overrun. ME1.02 • None ME1.03 • None ME1.04 • None P0.01 09/18/2023 • None ASPEN P0.02 BUILDING DEPARTMENT • None P1.01 • None P1.02 • None P1.03 • None 9/15/2023 Page 7 of 8 P1.04 • None P2.01 • None PE1.04 • None ELECTRICAL E0.00 • None E0.01 • None E0.02 • None E1.01 • None E2.01 • None E2.02 • None FOOD SERVICE RECEIVED FS 1 RECEIVED Ili • None FS2 09/18/2023 • None ASPEN FS3 BUILDING DEPARTMENT • None FS4 • None FS5 • Combi-Oven removed • Water filtration for combi-over removed 9/15/2023 Page 8 of 8