Loading...
HomeMy WebLinkAboutFile Documents.315 E Hyman Ave.0011-2023-BCOM (14) CORNINGOWENS 4111111111 FOAM U LAR° g( EXTRUDED POLYSTYRENE (XPS) RIGID FOAM INSULATION F O A M U LA R N G XTM Owens Corning®FOAMULAR®&FOAMULAR®NGX'"250 Extruded Polystyrene(XPS)insulations are closed-cell,moisture-resistant 250 rigid foam boards well suited to meet the needs of a wide variety of building applications' Both products are great for above-and below- grade residential and commercial applications,such as perimeter/ foundation,cavity wall,precast concrete,under slab,and other applications. FOAMULAR®NGX"250 contains the additional benefit of being manufactured with a blowing agent formulation that delivers a 90% reduction to Global Warming Potential(100 years),including the complete elimination of HFC 134a.2 1 Not for use in flat or low-slope roofing.For low-slope roofing applications,use FOAMULAR® &FOAMULAR®NGX"THERMAPINK®or FOAMULAR®&FOAMULAR®NGX"400/600/1000 Extruded Polystyrene(XPS)Rigid Foam insulation. 2 Compared to FOAMULAR®250 blowing agent formulation. Features Physical Properties" PROPERTY TEST METHODS VALUE • •••, Thermal Resistance,'R-Value,hrft2•°F/Btu ASTM C518 (RSI,°C•m2/W) @ 75°F(24°C)mean temperature 5.0(0.88) @ 40°F(4.4°C)mean temperature 5.4(0.95) @ 25°F(-3.9°C)mean temperature 5.6(0.99) SUPERIOR DURABLE EASY TO CUT, Long-Term Thermal Resistance, CAN/ULC LTTR-Value,7 minimum hr•ft2 F/Btu(RSI,°c•m2/W) S770-03 MOISTURE FORM & FIT @ 75°F(24°C)mean temperature 5.0(0.88) RESISTANCE Compressive Strength;minimum psi(kPa) ASTM D1621 25(172) Flexural Strength,'minimum psi(kPa) ASTM C203 50(345) Water Absorption,'maximum%by volume ASTM C272 0.3 Standards,Codes Compliance Water Vapor Permeance;°maximum perm ASTM E96 1.5(86) (ng/Pa.s.m2) • Meets ASTM C578 Type IV Dimensional Stability,maximum i linear change ASTM D2126 2.0 • UL Classification Certificate U-197 Flame Spread1112 ASTM E84 10 • Code Evaluation Report UL ER8811-01 Smoke Developed"'2 ASTM E84 175 • ASTM E119 Fire Resistance Rated Wall Assemblies3 Oxygen Index,"minimum%by volume ASTM D2863 24 Service Temperature,maximum°F(T) - 165(74) • Meets California Quality Standards;HUD UM#71a Linear Coefficient of Thermal Expansion,in/in/°F ASTM E228 3.5 x 10-5 (m/m/°C) (6.3 x 10-5) 3 Visit www.owenscorning.com for more details. 4 Properties shown are representative values for 1-inch-thick material,unless otherwise specified.Extruded Polystyrene Insulation may exhibit different physical properties based upon thickness.Certain physical properties are listed by minimum and maximum values Applications per ASTM C578.For details on specific Test Methods,please contact Owens Corning at PP 1-800-GET-PINK. • Under slabs 5 Modified as required to meet ASTM C578. 6 R means the resistance to heat flow;the higher the value,the greater the insulation • Perimeter/foundation walls power.This insulation must be installed properly to get the marked R-value.Follow the manufacturers instructions carefully.If a manufacturer's fact sheet is not provided with the CaVlt walls material shipment,request this and review it carefully.R-values vary,depending on many • yfactors,including the mean temperature at which the test is conducted and the age of the • Precast walls sample at the time of testing.The U.S.FTC requires the R-value of home insulation to be measured at 75°F mean temperature.R-value claims should always be compared at the • Weather-resistant barrier(when joints are sealed) same mean temperature.Because rigid foam plastic insulation products are not all aged in accordance with the same standards,it is useful to publish comparison R-value data.The R-value for FOAMULAR®&FOAMULAR®NGX"XPS insulation is provided from testing at mean temperatures of:-4°C(25°F),4.4°C(40°F),and 24°C(75°F),and aging techniques of 180-day real-time aged(as mandated by ASTM C578)and accelerated aging"Long-Term Thermal Resistance"(LTTR)per CAN/ULC S770-03. 7 Value at yield or 5%, hi deflection,evroccurs occurs first. CE I\fE 8 Value at yield or 5 i,whichever occurs first. 9 Data ranges from 0.00 to value shown due to the level of precisi t e D 10 Water vapor permeance decreases as thickness increases. 11 These laboratory tests are not intended to describe the hazards presented by this material under actual fire conditions. ^jin-i 2023 R® 12 Dataa from Underwriters Laboratories Inc.®classified.See ClassificatiO r c� -z Product Data Sheet I FOAMULAR®&FOAMULANGX'"250 XPS Insulation I SepASPgrN022 BUILDING DEPARTMENT Technical Information Certifications and Sustainable Features • FOAMULAR®&FOAMULAR® NGX°°XPS insulations are non-structural • Certified by SCS Global Services to contain an materials and must be installed on framing that is independently braced average of 20%recycled content pre-consumer. and structurally adequate to meet required construction and service-loading • GREENGUARD Certified products are certified conditions. to GREENGUARD standards for low chemical • FOAMULAR®&FOAMULAR® NGX'XPS insulations can be exposed to the emissions into indoor air during product usage. For exterior during normal construction cycles. During that time,some fading more information,visit ul.com/gg. of color may begin due to UV exposure,and if exposed for extended periods • Environmental Product Declaration(EPD) has been of time,some degradation or"dusting"of the polystyrene surface may begin. certified by UL Environment. It is best if the product is covered within 60 days to minimize degradation. ' Qualified as an ENERGY STAR®product,under the Once covered,the deterioration stops,and damage is limited to the thin U.S. Environmental Protection Agency and the U.S. top surface layers of cells.Cells below are generally unharmed and still Department of Energy. useful insulation. • Utilizing FOAMULAR®&FOAMULAR® NGX°°XPS insulation can help builders achieve green building • FOAMULAR®&FOAMULAR® NGX°°XPS insulations have a maximum certifications,including the U.S. Green Building service temperature of 165°F. Install only as much FOAMULAR®& Council's Leadership in Energy and Environmental FOAMULAR® NGX°°XPS insulation as can be covered in the same day. For Design(LEED®)certification. horizontal applications,always turn the print side down so the black print • UL CERTIFIED-See Bulk Shipment Certificate does not show to the sun,which may at times act as a solar collector,raising U-197 available at www.owenscorning.com/U197. the temperature of the foam under the print to an unacceptable level. • Do not cover FOAMULAR®or FOAMULAR®NGX'°XPS insulation,either a �• ,,_ r�ENERGY stored(factory-wrapped or unwra ed or partiallyinstalled,with dark- GREENGUARD �� �""" PARTNER unwrapped) GREENGUARD 10.Ec G.E.coNlEW colored(non-white)or clear(non-opaque)coverings and leave it exposed to the sun. Examples of such coverings include but are not limited to filter �� �� ° CERTIFIED NMEEMIV fabrics,membranes,temporary tarps,clear polyethylene,etc. If improperly covered and exposed to the right combination of sun,time,and temperature, FOAMULAR®and FOAMULAR®NGX°N XPS insulation deformation damage Environmental and Sustainability may occur rapidly.See Owens Corning publication"Heat Buildup Due to Solar Exposure Technical Bulletin"(Pub. No. 10015704)for more information. Owens Corning is a worldwide leader in building • This product is combustible.A protective barrier or thermal barrier is material systems,insulation,and composite solutions, required to separate this product from interior living or conditioned spaces servees.g Owensnsd range ofs committedquality productsvin and as specified in the appropriate building code. services. Corning is to driving sustainability by delivering solutions,transforming • All construction should be evaluated for the necessity to provide vapor markets,and enhancing lives. More information can be retarders.See current ASHRAE Handbook of Fundamentals. found at www.owenscorning.com. FOAMULAR®and FOAMULAR®NGX''XPS insulation use blowing agents with zero ozone depletion Product and Packaging Data potential. MATERIAL PACKAGING FOAMULAR®is manufactured with a polystyrene resin Extruded polystyrene closed-cell foam, Shipped in poly-wrapped units with individually and blend of HFC blowing agents that have a global ASTM C578 Type Iv,25 psi minimum wrapped or banded bundles THICKNESS PRODUCT PALLET(UNIT) SQUARE BOARD BUNDLES PIECES PIECES EDGES warming potential(100 years)of less than 750. (IN) DIMENSIONS DIMENSIONS FT PER FT PER PER PER PER FOAMULAR®NGX'" is manufactured with a THICKNESS (TYPICAL) PALLET PALLET PALLET BUNDLE PALLET X WIDTH X WIDTH polystyrene resin and a blend of HFO and HFC LENGTH(IN) X LENGTH X blowingagents that haveglobal in HEIGHT(FT) a warming % °4x24x96 4x8x4 1,920 1,536 4 30 120 Square Edge potential(100 years)of less than 80. I(half unit) ®x 48 x 96 4 x 8 x 4 1,920 1,536 2 30 60 Scored (half unit) Square Edge Disclaimer of Liability 1 1x24x96 4x8x4 1,536 1,536 8 24 96 Technical information contained herein is furnished without charge or 1 x 48 x 96 4 x 8 x 8 3,072 3,072 8 12 96 Tongue& obligation and is given and accepted at recipient's sole risk.Because 1 x 48 x 96 4 x 8 x 8 1,536 1,536 4 12 48 Groove conditions of use may vary and are beyond our control,Owens (half unit) Corning makes no representation about,and is not responsible or 1 x 48 x 108 4 x 9 x 8 3,456 3,456 8 12 96 liable for,the accuracy or reliability of data associated with particular 1 vz 1.5 x 24 x 96 4 x 8 x 8 2,048 3,072 8 16 128 uses of any product described herein.SCS Global Services provides 1.5 x 48 x 96 4 x 8 x 8 2,048 3,072 8 8 64 independent verification of recycled content in building materials and 2 2 x 24 x 96 4 x 8 x 4 768 1,536 4 12 48 verifies recycled content claims made by manufacturers.For more (half unit) information,visit www.SCsglobalservices.com. 2x24x108 4x9x8 1,728 3,456 8 12 96 LEED®is a registered trademark of the U.S.Green Building Council. 2 x 48 x 96 4 x 8 x 8 1,536 3,072 8 6 48 23'2 12.5x 24 x 96 4 x 8 x 8 1,152 2,880 8 9 72 2.5x48x96 4x8x8 1,152 2,880 4 9 36 Notes 3 3 x 24x 96 4x8x8 1,024 3,072 8 8 64 Not for use in roofing.For roofing applications,use FOAMULAR® 3x48x96 4x8x8 1,024 3,072 8 4 32 THERMAPINK®XPS insulation. 4 4 x 24 x 96 4 x 8 x 8 768 3,072 8 6 48 For additional information,refer to the Safe Use Instruction Sheet 4x48x96 4x8x8 768 3,072 8 3 24 (SUIS)foundintheSDSDatabaseviahttp://sds.owenscorning.com. Available lengths and edge configurations vary by thickness.Other sizes may be available upon request. Consult your local Owens Corning representative for availability. OWENS CORNING FOAM INSULATION,LLC ONE OWENS CORNING PARKWAY Limited Warranty TOLEDO,OH 43659 U rot FOAMULAR®&FOAMULAR®NGX'"XPS insulation limited lifetime warranty 111 maintains 90%of its R-value for the lifetime of the building and covers all ww oE 0 ASTM C578 properties.See FOAMULAR®Extruded Polystyrene Insulation Lifetime Limited Warranty for complete details,limitations,and requirements. Pub.No.43522-Q.Printe0145/A. pYe/b21123 The color PINK is a registered trademark of Owens Corning. ©2022 Owens Corning.All Ri hts Reserved. ASPEN BUILDING DEPARTMENT