HomeMy WebLinkAboutFile Documents.320 E Hyman Ave.0015-2024-BCOM (4) e e rn e n t ENVIRONMENTAL INC PO Box 2043 Glenwood Springs,CO 81602 josh@elementconsults.com (970) 274-3139 Property Address Asbestos Sampling Report Wheeler Opera House Date:04/05/2024 320 E. Hyman Ave. Aspen, CO 81611 +' Date of Inspection: 03/29/2024 Client: uElement Environmental Project#: Aspen Constructors Inc ACI 032924 Wheeler E 309 AABC Unit G a) Aspen, CO 81611 � Client Job Name Wheeler Opera House Attn: Justin Labier TABLE OF CONTENTS 1.0 -Scope of Work 2.0 -Sampling Requirements 0 3.0 -Sampling Methodology Building Inspector: 4.0 - Laboratory 5.0 -Suspect Materials Sampled Joshua Johnson 6.0 -Table of Results 7.0 - Description of Sampling Area CDPHE#18401 8.0 -Conclusion 9.0 - Lab Report 10.0 -Certificates Asbestos Samples Analyzed: 2 Positive Asbestos Samples: 0 O RE`: Q E D N Q 04/11/2024 ASPEN BUILDING DEPARTMENT 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: -Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.-5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples -Miscellaneous materials- Minimum of 2 samples -Thermal Systems Insulation(TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The friable materials are segregated into separate homogenous areas. The size of the sampling area is determined. Samples are taken according to a random numerical sequence of the subareas, following guidelines per the EPA Pink Book: Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials. 4.0- Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401, performed the inspection. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or<1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional "point count" performed to be considered less than 1% and not be regulated by the CDPHE. The lab's documents with analyses and findings are found below RECEIVED po box 2043, glenwood springs, cJ 8602 24 e e m e n t 970.274.3139 www.elementconsults.com ENVIRONMENTAL 1N(; ASBESTOS LEAD ENVIRO4 I 1L Project#-ACI 032924 Wheeler BUILDING DEPARTMENT 3 5.0- SUSPECT MATERIALS SAMPLES • Drywall • Texture • Joint Compound • Tape 6.0- TABLE OF RESULTS HOMOGENOUS DESCRIPTION OF AREA ACM CATEGORY NUMBER APPROXIMATE ACM ASSESSMENT CATEGORIES %AND TYPE OF AREA OF SQ.FT.* ASBESTOS FOUND SAMPLES (A) Drywall System above Stage Miscellaneous 2 —1,100 sq.ft. Friable Non-ACM No Asbestos Detected Key: ACM Assessment Categories: 1-Damaged or significantly damaged Thermal Systems Insulation 7-Friable ACM with low potential for damage (TSI)ACM Other-ACM not classified in the above Assessment Categories 2-Damaged friable surfacing ACM N/A-Not Applicable 4-Damaged or significantly damaged friable Miscellaneous ACM 5-ACM with potential for damage *Square footage is estimated and not for bidding purposes 6-ACM with potential for significant damage 7.0- DESCRIPTION OF SAMPLING AREA • Drywall System in partition wall in attic above the stage to add Motor Carrier System RECEIVED po box 2043, glenwood springs, cu 8.7602 1 24 e e m en t 970.274.3139 www.elementconsults.com ENVIRONMENTAL 1N(; ASBESTOS LEAD ENVIRONSIIPENL Project#-ACI 032924 Wheeler BUILDING DEPARTMENT 4 Sampling Locations NI Al A2 NTS 8.0- CONCLUSION No asbestos was detected in any of the samples taken. Sincerely, Josh Johnson po box 2043, glenwood springs. co 81g0? e e m e n t 970.274.3139 www.elem(, ,c.,,E ult�. o n E ENVIRONMENTAL INC, ASBESTOS LEAD ENVIRONMENTAL Project#-ACI 032924 Wheeler 04/11/2024 ASPEN BUILDING DEPARTMENT 5 9.0- LAB REPORT tiff• eurofins CEI ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for Element Environmental LLC CLIENT PROJECT: Aspen Constructors 032924 LAB CODE: B246397 TEST METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORT DATE: 04/05/24 TOTAL SAMPLES ANALYZED: 2 #SAMPLES>1%ASBESTOS: 730 SE Maynard Road •Cary, NC 27511 •919.481.1413 po box 2043,glenwood springs, co 81602 e e m e n t 970.274.3139 www.eleme c::.cults.corn ED ENVIRONMENTAL INC ASBESTOS LEAD ENVIRONMENTAL Project#-ACI 032924 Wheeler 04/11/2024 ASPEN BUILDING DEPARTMENT 6 .• eurofins Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY CEI PROJECT: Aspen Constructors 032924 LAB CODE: B246397 METHOD: EPA 600/R93/116 and EPA 600/ M4-82/020 ASBESTOS Client ID Layer Lab ID Color Sample Description Al Layer 1 B246397.01 Off-white,White Joint Compound None Detected Layer 2 B246397.01 Off-white,Brown Drywall None Detected A2 Layer 1 B246397.02 Off-white,White Joint Compound None Detected Layer 2 B246397.02 Off-white,Brown Drywall None Detected 730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 1 of 1 po box 2043,glenwood springs. co 81602 - � e e m e n 't 970.274.3139 www.elem( : .c.r.sults.co:n �� ENVIRONMENTAL INC ASBESTOS LEAD ENVIRONMENTAL Project#-ACI 032924 Wheeler 04/11/2024 ASPEN BUILDING DEPARTMENT 7 .:.• eurofins ASBESTOS BULK ANALYSIS ti• By: POLARIZING LIGHT MICROSCOPY CEI Client: Element Environmental LLC Lab Code: B246397 2314 Stone Creek Court Date Received: 04-02-24 Grand Junction, CO 81507 Date Analyzed: 04-05-24 Date Reported: 04-05-24 Project: Aspen Constructors 032924 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous Al Joint Compound Heterogeneous <1% Cellulose 5% Paint None Detected Layer 1 Off-white,White 35% Calc Carb B246397.01 Non-fibrous 60% Binder Bound Layer 2 Drywall Heterogeneous 20% Cellulose 75% Gypsum None Detected B246397.01 Off-white,Brown 5% Fiberglass Fibrous Bound A2 Joint Compound Heterogeneous <1% Cellulose 5% Paint None Detected Layer 1 Off-white,White 35% Calc Carb B246397.02 Non-fibrous 60% Binder Bound Layer 2 Drywall Heterogeneous 20% Cellulose 75% Gypsum None Detected B246397.02 Off-white,Brown 5% Fiberglass Fibrous Bound 730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 1 of 2 po box 2043,glenwood springs. cn 81602 e e m e n t 970.274.3139 www.eleme r,c.,,r ultr.,,e n ENVIRONMENTAL hr,`. ASBESTOS LEAD ENVIRONMENTAL Project#-ACI 032924 Wheeler 04/11/2024 ASPEN BUILDING DEPARTMENT 8 eurofins CEI LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb =Calcium Carbonate METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORTING LIMIT: <1%by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points REGULATORY LIMIT: >1%by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on inquest. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID and sample description. ANALYST: Zue CPC APPROVED BY: Santi fVicolella Tianbao Bai,Ph.D.,CIH Laboratory Director NVLA TESTING NVLAP LAB CODE 101768-0 730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 2 of 2 po box 2043,glenwood springs. co 81g0? e e m e n t 970.274.3139 www.eleme: ,c ulto.,,o n ED ENVIRONMENTAL INC ASBESTOS LEAD ENVIRONMENTAL Project#-ACI 032924 Wheeler 04/11/2024 ASPEN BUILDING DEPARTMENT 9 ASBESTOS r(-- SAMPLING FORM CE IL-.Aas COMA —06111 , Company Liement Environmental Job Contact Josh Johnson Project Name 4 'i., le.,<f.<.hs '329Ly Proect ID# vtiri/„i• UPi^ Tel 970-274-3139 •11 c-,tn ,04s j7..•.di r PLM I ITEM ,42 r— PLM I I TEM PLM I I TEM PLM I J TEM ( PLM (STEM PLM I 1 TEM 7' PLM I I TEM I PLM I TEM 7- PLM E]TEM PLM I -�TEM PLM 7-1 TEM f 7 PLM [1 TEM �- PLM 1--ITEM PLM I ITEM .1 PLM I ITEM I— PLM j ITEM I PLM I ITEM PLM I ITEM PLM [ ITEM I PLM i 1 1 TEM I PLM r"—I TEM PI M I ITEM �— PL,M I TEM I PLM I ITEM I PLM JTEM 1 i PLM I I TEM . PLM J ITEM 011 PLM I J TEM Page �t VERSION CCOC 0215 2(2 LI) Customer COC Page 2 po box 2043, glenwood springc. 81P0? e e m en t 970.274.3139 www.elemt, c.raults.co:n ENVIRONMENTAL INC ASBESTOS LEAD ENVIRONMENTAL Project#-ACI 032924 Wheeler 04/11/2024 ASPEN BUILDING DEPARTMENT 10 10.0— CERTIFICATES •.,i74 '!react s' tp ,: i; .F Colorado Department (• ` m. of Public Health j- `< •r-H and Environment - y ASBESTOS l`' CERTIFICATION* ?ai., This certifies that f t t_' Joshua Jay Johnson `' Certification No,:18401 a has met the requirements of 25-7-507,C.R.S.and Air Quality Control •n Commission Regulation No.8.Pan B,and is hereby certified by the 4 • �• state of Colorado in the following discipline. g N Project Designer* : �` n a/� , Issued: Marc ,-.0 Expires: March 27,2025 ; .. .A ; rs ',4 nv ir.rih•a . t 1 t k s � r _ . t ! - }'� RAC Q ITk:rr aTI 1 a I Colorado Department C �f Public Health d Environment ,1 i ASBESTOS CONSULTING FIRM +,' This certifies that Element Environmental,Inc. Registration No.:ACF-21640 ,J has met the registration requirements of 25-7-507.C.R.S.and the Air Quality Control Commission Regulation No.8.Part B.and is hereby authorized to perform asbestos consulting activities as required under Regulation No 8.Part B.in the state of Colorado. Issued- January 22 2023 Expires: January 30,2025 po box 2043, glenwood springs. crl 81A0? e e m e n t 970.274.3139 www.eleme, ,c.raults.co:n En ENVIRONMENTAL/Ivc' ASBESTOS LEAD ENVIRONMENTAL Project#-ACI 032924 Wheeler 04/11/2024 ASPEN BUILDING DEPARTMENT