Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.315 E Hyman Ave.0011-2023-BCOM (15)
ESICC EVALUATION SERVICE ICC-ES Evaluation Report ESR-3500 Reissued January 2021 This report is subject to renewal January 2022. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council'Ce' DIVISION: 07 00 00—THERMAL AND MOISTURE assemblies. ceiling assemblies. exterior side of vertical PROTECTION foundations or the underside of on-grade slabs. The Section: 07 21 00—Thermal Insulation insulation is also for use in attics and crawl spaces when installed in accordance with Section 4.4.Under the IRC and REPORT HOLDER: the 2018 and 2015 IBC. the insulation may be used as air- impermeable insulation when installed in accordance with ICYNENE. INC. Section 3.4. and as a vapor retarder when installed in accordance with Section 3.5. Icynene ProSeal and Icynene EVALUATION SUBJECT: ProSeal LE spray foam may be used in fire-resistance-rated construction when installed in accordance with Section 4.5. ICYNENE PROSEAL. ICYNENE PROSEAL LE. ICYNENE and in Types I through IV construction when installed in PROSEAL H5 AND PROSEAL H5-O accordance with Section 4.6. The insulation may be used as an alternative to the water-resistive barrier required in IBC 1.0 EVALUATION SCOPE Section 1404.2 and IRC Section R703.2 when installed as 1.1 Compliance with the following codes: described in Section 4.7. • 2018. 2015. 2012 and 2009 International Building Code' 3.0 DESCRIPTION (IBC) 3.1 ProSeal Insulation: • 2018. 2015. 2012 and 2009 International Residential Icynene ProSeal and Icynene ProSeal LE foam plastic Code''(IRC) insulation is a two-component. medium-density. closed-cell. • 2018. 2015. 2012 and 2009 International Energy spray-applied foam plastic with a nominal density of 2.4 pcf. Conservation Code''(IECC) Icynene ProSeal H5 and Icynene ProSeal H5-O foam plastic insulation is a two-component. medium-density. closed-cell. Properties evaluated: spray-applied foam plastic with a nominal density of 1.5 pcf. • Surface-burning characteristics The polyurethane foam is produced by combining Icynene Based Seal MDI isocyanate(the A component)and Icynene • Physical properties ProSeal resin (the B component).The products have a shelf • Thermal resistance(R-values) life of 12 months when stored in factory-sealed containers • Attic and crawl space installation at temperatures between 60°F and 85°F (16"C and 29"C). The Icynene ProSeal is supplied in one formula for all • Air permeability climates. • Vapor permeability The attributes of the insulation have been verified as • Fire—resistance-rated construction conforming to the requirements of ICC 700-2008 Section 703.2.1.1.1(c) as an air impermeable insulation. Note that • Water-resistive barrier decisions on compliance for those areas rest with the user • Exterior walls of Types I—IV construction of this report. The user is advised of the project-specific provisions that may be contingent upon meeting specific 1.2 Evaluation to the following green standard: conditions.and the verification of those conditions is outside 2008 ICC 700 National Green Building StandardTm the scope of this report. These codes or standards often (ICC 700-2008) provide supplemental information as guidance. Attributes verified: 3.2 Surface Burning Characteristics: See Section 3.1 The Icynene ProSeal and Icynene ProSeal LE insulation. at 2.0 USES a maximum thickness of 4 inches (102 mm) and a nominal density of 2.4 pcf and Icynene ProSeal H5 and Icynene Icynene ProSeal. Icynene ProSeal LE. Icynene ProSeal H5 ProSeal H5-O at a maximum thickness of 4 inches (102 and Icynene ProSeal H5-O spray foam is used as a mm) and a nominal density of 1.5 pcf. have a flame-spread nonstructural thermal insulating material in Types I. II. III. IV index of 25 or less and a smoke-developed index of 450 or and V construction under the IBC and dwellings under less when tested in accordance with ASTM E84 the IRC. The insulation is for use in wall cavities. floor (UL 723). ICC-ES'Eralnanon Reports are nor to be construed as 7 Epresenring aesthetics or am odic) am ibures nor specifically addressed,nor are then to be construed aNS� as an endorsement of the subject of the report or a reromnnendation for its use There is no warranty bi ICC Evaluation Service,LLC,express or implied,as % to a,n finding or other matter in this report,or as to am product covered bi the report aK — ,,, Copyright©2021 ICC Evaluation Service,LLC All rights reserved Page 1 of 7 ESR-3500 Most Widely Accepted and Trusted Page 2 of 7 3.3 Thermal Resistance: in unventilated attic spaces regulated by 2018. 2015 and Icynene ProSeal and Icynene ProSeal LE insulation has a 2012 IRC Section R806.5 (2009 IRC Section R806.4) or thermal resistance. R-value. at a mean temperature of 75'F 2018 IBC Section 1202.3 (2015 IBC Section 1203.3), the as shown in Table 1. insulation must be installed at a minimum thickness of 1.4 inches (35.6 mm). Where Icynene ProSeal H5 and Icynene Icynene ProSeal H5 and Icynene ProSeal H5-O insulation ProSeal H5-O is used as an air-impermeable barrier. such has a thermal resistance. R-value. at a mean temperature as in unventilated attic spaces regulated by 2018. 2015 and of 75"F(24'C) as shown in Tables 2 and 3. respectively. 2012 IRC Section R806.5 (2009 IRC Section R806.4) or 3.4 Air Permeability: 2018 IBC Section 1202.3 (2015 IBC Section 1203.5). the insulation must be installed at a minimum thickness of 1 inch Icynene ProSeal and Icynene ProSeal LE insulation. at a (25.4 mm). The insulation is applied to the intended minimum 1.4-inch (35.6 mm) thickness. is considered thickness. with the first pass being at the maximum air-impermeable insulation in accordance with 2018 IBC thickness set forth in the manufacturer's published Section 1202. (2015 IBC Section 1203.3) and 2018. 2015 installation instructions. Where multiple passes are and 2012 IRC Section R806.5 (2009 IRC Section R806.4). required.the cure time between each pass is in accordance based on testing in accordance with ASTM E2178. with the manufacturer's instructions. Icynene ProSeal H5 and Icynene ProSeal H5-O insulation. 4.3 Thermal Barrier: at a minimum 1.0-inch (25.4 mm) thickness. is considered 4.3.1 Application with a Prescriptive Thermal Barrier: air impermeable insulation in accordance with 2018 IBC Icynene ProSeal. Icynene ProSeal LE. Icynene ProSeal H5 Section 1202.3 (2015 IBC Section 1203.3) and 2018, 2015 and Icynene ProSeal H5-O spray foam insulation must be and 2012 IRC Section R806.5 (2009 IRC Section R806.4), separated from the interior of the building by an approved based on testing in accordance with ASTM E2178. thermal barrier. When installation is within an attic or crawl 3.5 Vapor Permeability: space as described in Section 4.4. a thermal barrier is not Icynene ProSeal and Icynene ProSeal LE insulation ha a required between the foam plastic and the attic or crawl vapor permeance of less than 1 perm (5.7x10-11 kg/ space.but is required between the insulation and the interior Pa s m') at a minimum thickness of 1.5 inches (38.1 mm) of the building. There is no thickness limit when installation is behind a code-prescribed thermal barrier except as noted and may be used where a Class II vapor retarder is required in Sections 4.4.2.1.4.4.2.2 and 4.4.3. by the applicable code. 4.3.2 Application without a Prescriptive Thermal Icynene ProSeal H5 insulation has a vapor permeance of Barrier with DC 315 Coating: Icynene ProSeal and less than 1 perm (5.7x10-11 kg/Pa-s-m') at a minimum Icynene ProSeal LE may be installed without the approved thickness of 2.25 inches(57.2 mm)and may be used where thermal barrier prescribed in IBC Section 2603.4 and IRC a Class II vapor retarder is required by the applicable code. Section R316.4. when the installation is in accordance with Icynene ProSeal H5-O insulation has a vapor permeance this section.The Icynene ProSeal insulation and the DC 315 of less than 1 perm (5.7x10-11 kg/Pa-s-m-) at a minimum Coating may be spray-applied to the interior facing of walls. thickness of 2 inches (25.4 mm) and may be used where a the underside of roof sheathing or roof rafters. and in crawl Class II vapor retarder is required by the applicable code. spaces.and may be left exposed as an interior finish without a 15-minute thermal barrier or ignition barrier. The thickness 3.6 Coatings: of the insulation applied to the underside of the roof 3.6.1 DC 315: DC 315 Coating(ESR-3702), manufactured sheathing must not exceed 14 inches (356 mm). The by International Fireproof Technology, Inc./Paint to Protect thickness of the insulation applied to vertical wall surfaces Inc.. is a water-based coating supplied in 5-gallon (19 L) must not exceed 8 inches(203 mm). The insulation must be pails and 55 gallon(208 L)drums. The coating material has covered on all surfaces with DC 315 Coating at a minimum a shelf life of 12 months when stored in factory-sealed wet film thickness of 24 mils wet(0.61 mm)[16 mils dry(0.41 containers at temperatures between 50°F (10:C) and 80°F mm)] at an application rate of 1 gallon (3.8 L) per 66.8 (27:C) square feet(6.15 M2). The coating must be applied over the Icynene ProSeal insulation in accordance with the coating 4.0 DESIGN AND INSTALLATION manufacturer's instructions, ESR-3702 and this report. 4.1 General: Surfaces to be coated must be dry. clean. and free of dirt. loose debris and other substances that could interfere with Icynene ProSeal. Icynene ProSeal LE, Icynene ProSeal H5 adhesion of the coating. The coating is applied in one coat and Icynene ProSeal H5-O must be installed in accordance with low-pressure airless spray equipment. with the manufacturer's published installation instructions. this report and the applicable code. The manufacturer's 4.4 Attics and Crawl Spaces: published installation instructions and this report must be 4.4.1 Application with a Prescriptive Ignition Barrier: strictly adhered to. and a copy of the instructions and this When Icynene ProSeal. Icynene ProSeal LE. Icynene evaluation report must be available on the jobsite at all times ProSeal H5 and Icynene ProSeal H5-O insulation is during installation. installed within attics or crawl spaces where entry is made 4.2 Application: only for service of utilities. an ignition barrier must be installed in accordance with IBC Section 2603.4.1.6 or IRC Icynene ProSeal. Icynene ProSeal LE. Icynene ProSeal H5 Sections R316.5.3 and R316.5.4. as applicable. The ignition and Icynene ProSeal H5-O must be applied using spray barrier must be consistent with the requirements for the type equipment specified by Icynene. Inc. The insulation must of construction required by the applicable code. and must not be used in areas having a maximum service be installed in a manner so that the foam plastic insulation temperature greater than 180°F(82"C).must not be used in is not exposed. Icynene ProSeal and Icynene ProSeal LE electrical outlet or junction boxes or in contact with rain or insulation may be installed in unvented attics in accordance water. and must be protected from the weather during and with 2018 IBC Section 1202.3(2015 IBC Section 1203.3)or after application. Where Icynene ProSeal and Icynene 2018. 2015 and 2012 IRC Section R806.5 (2009 IRC ProSeal LE is used as an air-impermeable barrier. such as Section R806.4). ESR-3500 Most Widely Accepted and Trusted Page 3 of 7 4.4.2 Application without a Prescriptive Ignition 4.5 One-hour Non-load-bearing Fire-resistance-rated Barrier: Where Icynene ProSeal spray foam is installed in Wall Assembly: an attic or crawl space without a prescriptive ignition barrier. 4.5.1 Exterior Face: Nominally 6-inch-deep(152 mm). No. in accordance with Sections 4.4.2.1 and 4.4.2.2. the 18 gage galvanized steel studs. spaced 16 inches following conditions apply: (406 mm)on center.are fastened to No. 18 gage galvanized 1. Entry to the attic or crawl space is only for the service of steel floor and ceiling tracks. One layer of utilities and no storage is permitted. 1/-1-inch-thick (12.7 mm) Georgia Pacific DensGlass'= Gold 2. There are no interconnected attic. crawl space or Exterior Sheathing is installed parallel to the steel studs with basement areas. vertical joints offset a minimum of 16 inches (406 mm)from the vertical joints of the interior Type X gypsum board. and 3. Air in the attic or crawl space is not circulated to other the horizontal joints offset a minimum of 24 inches parts of the building. (610 mm) from the horizontal joints of the gypsum board. 4. Combustion air is provided in accordance with IMC The sheathing is attached using 1 i/4 inch long (31.7 mm), (International Mechanical Code'')Section 701. self drilling drywall screws spaced 8 inches (203 mm) on center around the perimeter and in the field. Hohmann& 5. Attic ventilation is provided when required by 2018 IBC Barnard DW-10 brick ties. 6 inches (152 mm) long Section 1202.2 (2015. 2012 and 2009 IBC Section by 11/2 inches (38 mm) wide. are spaced 16 inches 1203.2) or IRC Section R806. except when (406.4 mm) on center vertically on each steel stud. and air-impermeable insulation is permitted in unvented secured using two 15/8-inch-long (41.3) self-drilling screws. attics in accordance with 2018 IBC Section 1202.3 through 4-inch (102 mm) red clay brick [31/2 inches (2015 IBC Section 1203.3)or 2018. 2015 and 2012 IRC (89 mm) by 21/4 inches (57 mm) by 73/4 inches Section R806.5 (2009 IRC Section R806.4). (197 mm)]. laid in a running bond pattern with Type S 6. Under-floor (crawl space) ventilation is provided when mortar. leaving a nominally 1-inch (25.4 mm) air gap required by 2018 IBC Section 1202.4[2015 IBC Section between the brick and the exterior sheathing. The stud 1203.4 (2012 and 2009 IBC Section 1203.3)] or IRC cavity is filled with Icynene ProSeal insulation and Icynene Section R408.1, as applicable. ProSeal LE to a maximum nominal thickness of 6 inches. 4.4.2.1 Attics and Crawl Spaces - Uncoated: The 4.5.2 Interior Face: Type X gypsum board. 5/ inch thickness of the Icynene ProSeal and Icynene ProSeal LE (15.9 mm)thick and complying with ASTM C1396.is applied foam lastic a lied to the underside of the roof sheathingto the interior side with the long edge parallel to steel studs. and/or rafters. op the underside of floors. must not exceed 8 and is secured using 11/4-inch-long (32 mm). self-drilling inches(203 mm).The thickness of the spray foam insulation drywall screws spaced 8 inches(203 mm) on center around the perimeter and 12 inches(305 mm)on center in the applied to vertical wall surfaces must not exceed 6 inches field. (152 mm). The insulation does not require a code- The gypsum board joints must be treated with vinyl or prescribed ignition barrier or coating. casein. dry or premixed joint compound applied in two coats to cover all exposed screw heads and gypsum board butt The thickness of the Icynene ProSeal H5 and Icynene joints. A minimum 2-inch-wide (51 mm) paper. plastic. or ProSeal H5-O foam plastic applied to the underside of the fiberglass tape is embedded in the first layer of compound roof sheathing and/or rafters. or the underside of floors. over butt joints of the gypsum board. must not exceed 6 inches (152 mm). The thickness of the 4.6 Exterior Walls in Type I, II, III and IV Construction: spray foam insulation applied to vertical wall surfaces must not exceed 6 inches (152 mm). The insulation does not 4.6.1 General: When used on exterior walls of Types I. II. require a code-prescribed ignition barrier or coating. III or IV construction. the assembly must comply with IBC 4.4.2.2 Attic and Crawl Spaces-Coated: The thickness Section 2603.5 and this section. and the Icynene ProSeal of the Icynene ProSeal and Icynene ProSeal LE foam plastic and Icynene ProSeal LE insulation must be installed at a maximum thickness as described in Table 4. The potential applied to the underside of the roof sheathing and/or rafters. heat of Icynene ProSeal insulation is 2288 Btu/ft or the underside of floors. must not exceed 14 inches (356 (25995 kJ/m2) per inch of thickness. when tested in mm). The thickness of the spray foam insulation applied to accordance with NFPA 259. vertical wall surfaces must not exceed 8 inches (203 mm). 4.6.2 Specific Wall Assemblies: Wall assemblies The Icynene ProSeal and Icynene ProSeal LE insulation complying with Section 4.6 must be as described in must be covered on all surfaces with DC 315 Coating at a Table 4. minimum dry film thickness of 3 mils (0.08 mm) [wet film thickness of 4 mils (0.10 mm)] at a rate of 401 square feet 4.7 Water-resistive Barrier: (37 m2) per gallon (3.8 L). Icynene ProSeal and Icynene ProSeal LE insulation may be The DC 315 Coating must be applied over the Icynene used as an alternative to the water-resistive barrier ProSeal and Icynene ProSeal LE insulation in accordance prescribed in IBC Section 1404.2 and IRC Section R703.2. with the coating manufacturer's instructions and this report. when installed on exterior walls as described in this section Surfaces to be coated must be dry. clean. and free of dirt. the insulation must be spray-applied to the exterior side of loose debris and other substances that could interfere with sheathing.masonry or other suitable exterior wall substrates adhesion of the coating. The coating is applied in one coat to form a continuous layer of 1 inch (25.4 mm) minimum with low-pressure airless spray equipment. thickness. All construction joints and penetrations are to be completely sealed with Icynene ProSeal or Icynene ProSeal 4.4.3 Use on Attic Floors: Icynene ProSeal and Icynene LE insulation. ProSeal LE insulation may be installed exposed at a maximum thickness of 14 inches (356 mm) between and 5.0 CONDITIONS OF USE over the joists in attic floors. The insulation must be The Icynene ProSeal. ProSeal LE. Icynene ProSeal H5 and separated from the interior of the building by an approved Icynene ProSeal H5-O spray foam insulation described in thermal barrier. An ignition barrier in accordance with the this report complies with. or is a suitable alternative to what IBC Section 2603.4 and IRC Section R316.5.3 may be is specified in. those codes listed in Section 1.0 of this omitted. report. subject to the following conditions: ESR-3500 Most Widely Accepted and Trusted Page 4 of 7 5.1 The product must be installed in accordance with 6.4 Engineering analysis of a fire-resistance test in the manufacturer's published installation instructions. accordance with ASTM E119. this evaluation report and the applicable code. In the 6.5 Engineering analysis of a fire test in accordance with event of a conflict between the manufacturer's NFPA 285. published installation instructions and this report. this report governs. 6.6 Report of a room corner fire test in accordance with 5.2 The insulation must be separated from the interior of NFPA 286. the building by an approved thermal barrier in 6.7 Report of a potential heat test in accordance with NFPA accordance with IBC Section 2603.4. except when 259. installation is as described in Section 4.3.2 or in attics 6.8 Report of a critical radiant flux test in accordance with and crawl spaces as described in Section 4.4.2. ASTM E970. 5.3 The insulation must not exceed the thickness and 6.9 Reports of tests in accordance with applicable sections density noted in Sections 3.2, 4.3, 4.4, 4.5 and 4.6 of of the ICC-ES Acceptance Criteria for Foam Plastic this report. Sheathing Used as Water-resistive Barriers (AC71). 5.4 The insulation must be protected from the weather dated February 2013 (editorially revised January during and after application. 2018). 5.5 The insulation must be applied by installers certified by 7.0 IDENTIFICATION Icynene, Inc. 7.1 Containers of Icynene ProSeal. Icynene ProSeal LE. 5.6 Use of the insulation in areas where the probability of Icynene ProSeal H5 and Icynene ProSeal H5-O termite infestation is ''very heavy" must be in components are identified with a label bearing the accordance with IRC Section R318.4 or 2018. 2015 Icynene. Inc.. name and address: the product trade and 2012 IBC Section 2603.9 (2009 IBC Section name [Icynene ProSeal]: the lot number: the flame 2603.8). as applicable. spread and smoke developed indices: mixing 5.7 Jobsite certification and labeling of the insulation must instructions: density: the shelf life and the expiration comply with 2018 or 2015 IRC Sections N1101.10.1 date: and the evaluation report number(ESR-3500). and N1101.10.1.1 (2012 IRC Sections N1101.12.1 and The International Fireproof Technology Inc. / Paint N1101.12.1.1 or 2009 IRC Sections N1101.4 and To Protect. Inc.. DC 315 intumescent coating is N1101.4.1) and 2018. 2015 and 2012 IECC Sections identified with the manufacturer's name. the product C303.1.1. C303.1.1.1. R303.1.1 and R303.1.1.1 (2009 trade name and address. use date of manufacture. I ECC Sections 303.1.1 and 303.1.1.1). as applicable. shelf life or expiration date. manufacturer's instructions 5.8 The A and B components of the insulation are and evaluation report number(ESR-3702). produced under a quality-control program with 7.2 The report holder's contact information is the following: inspections by ICC-ES. ICYNENE, INC. 6.0 EVIDENCE SUBMITTED 6747 CAMPOBELLO ROAD 6.1 Data in accordance with the ICC-ES Acceptance MISSISSAUGA, ONTARIO L5N 2L7 CANADA Criteria for Spray-applied Foam Plastic Insulation. (AC377). dated April 2016 (editorially revised April (905) 363-4040 www.icynene.com 2018). including reports of tests in accordance with Appendix X of AC377. 6.2 Report of air permeance test in accordance with ASTM E2178. 6.3 Report of vapor permeance test in accordance with ASTM E96. TABLE 1-THERMAL RESISTANCE(R-VALUES)PROSEAL AND PROSEAL LE THICKNESS(inches) R-VALUE(°F.W.h/Btu) 1.0 7.1 3.5 24 4.0 28 5.5 38 6.0 42 7.5 52 8.5 59 9.5 66 10.0 69 11.25 78 For SI:1 inch=25 4 mm, 1°F_ft2_h/Btu=0.176110°K.m2_h/W_ 'R-values are calculated based on tested K-values at 1-and 3.5-inch thicknesses ESR-3500 I Most Widely Accepted and Trusted Page 5 of 7 TABLE 2—THERMAL RESISTANCE(R-VALUES)PROSEAL H5 THICKNESS(inches) R-VALUE(°F.ft2.hBtu) 1.0 6 7 3.5 24 4.0 27 5.5 37 6.0 41 7.5 51 8.5 58 9.5 65 10.0 68 11.25 76 For SI:1 inch=25.4 mm; 1°F.ft2.h/Btu=0.176110°K.m2.h/W. 'R-values are calculated based on tested K-values at 1-and 3.5-inch thicknesses. TABLE 3—THERMAL RESISTANCE(R-VALUES) PROSEAL H5-0 THICKNESS(inches) R-VALUE(°F.ft2.hBtu) 1.0 7.2 3.5 25 4.0 29 5.5 39 6.0 43 7.5 54 8.5 61 9.5 68 10.0 72 11.25 81 For SI:1 inch=25.4 mm; 1°F.ft2.hBtu=0.176110°K.m2.h/W. 'R-values are calculated based on tested K-values at 1-and 3.5-inch thicknesses. ESR-3500 I Most Widely Accepted and Trusted Page 6 of 7 TABLE 4—NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES WALL COMPONENT MATERIALS Base Wall System- 1 -Concrete wall. Use either 1,2 or 3 2-Concrete masonry wall. 3-Minimum 35/8-inch-deep(92 mm),No.20 gage,C-shaped steel studs,spaced a maximum of 24 inches on center with lateral bracing every 4 feet(1219 mm)as required by code.Sheathing shall be a described in Exterior Sheathing below. Floorline Firestopping Minimum 4 pcf mineral wool in each stud cavity at each floorline,attached with Z-clips.Thickness must match stud cavity depth. Cavity Insulation-Use either 1,2 3,4 1-None. or 5 2-Partial cavity fill with a maximum air space of 2 inches(51 mm)or full cavity depth not exceeding 75/8 inches(194 mm)of Classic,Classic Plus or Classic Max(ESR-1826); MD-R-210(ESR-3493);or ProseaVProSeal LE(ESR-3500). 3-Any insulation qualified as noncombustible in accordance with ASTM E136. 4-Glass fiber batt insulation'. 5-Mineral fiber insulation". "Insulation must comply with the applicable requirements of 2015 or 2012 IBC Section 720.2(2009 IBC Section 719.2). Exterior Sheathing-Only for Base Wall 1 -Minimum 1/2-inch-thick(12.7 mm),),glass mat gypsum sheathing complying with ASTM C1177. System No.3- 2-Sheathing shall be attached with No.6, 11/4-inch-long(32 mm)self-tapping screws located 8 Use either 1 or 2 inches(203 mm)on center along the perimeter and 12 inches 302 mm)on center in the field of wallboard.Joints must be taped and treated with joint compound in accordance with ASTM C840 or GA-216. Exterior Insulation Maximum thickness of 51/2 inches(140 mm)of Proseal Eco(MD-R-210)(ESR-3493)or ProseaVProSeal LE(ESR-3500). Exterior Wall Covering- 1 -Brick-standard nominally 4-inch-thick(102 mm)clay brick;brick veneer anchors-standard Use either 1,2,3,4, 5,6 or 7 types installed a maximum of 24 inches OC vertically on each stud'. 2-Stucco-minimum 3/4-inch-thick(19.1 mm),exterior cement plaster and lath with a secondary water-resistive barrier may be installed between the exterior insulation and the lath. 3-Natural stone(limestone,granite, marble,sandstone), minimum 2-inch-thick(51 mm)°. 4-Cast artificial stone, minimum 11/2-inch-thick(38 mm),complying with AC51 and subject of a current ICC-ES evaluation report°. 5-Terracotta cladding, minimum of 11/4-inch-thick(32 mm)°. 6-Precast concrete panels, minimum of 11/2-inch-thick(32 mm)°. 7-Concrete masonry units(CMU), minimum of 11/2 inch-thick(38 mm)°. ° The maximum air gap between exterior insulation and cladding shall be 2 inches(51 mm). °.Any standard non-open-jointed installation technique such as shiplap,etc., may be used. ESICC EVALUATION SERVICE ICC-ES Evaluation Report ESR-3500 CBC, CRC and CEC Supplement Issued January 2021 This report is subject to renewal January 2022. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council'' DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: ICYNENE, INC. EVALUATION SUBJECT: ICYNENE PROSEAL, ICYNENE PROSEAL LE, ICYNENE PROSEAL H5 AND ICYNENE PROSEAL H5-0 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Icynene ProSeal. Icynene ProSeal LE. Icynene ProSeal H5 and Icynene ProSeal H5-0. described in ICC-ES evaluation report ESR-3500. have also been evaluated for the codes noted below. Applicable code editions: • 2019 California Building Code(CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD) and Division of the State Architect (DSA). see Sections 2.1.1 and 2.1.2 below. • 2019 California Residential Code(CRC) • 2019 California Energy Code (CEC) 2.0 CONCLUSIONS 2.1 CBC and CRC: The Icynene ProSeal. Icynene ProSeal LE. Icynene ProSeal H5 and Icynene ProSeal H5-0. described in Sections 2.0 through 7.0 of the evaluation report ESR-3500. comply with the 2019 CBC and CRC. provided the design and installation are in accordance with the 2018 International Building Code''(IBC)and International Residential Code'' (IRC)provisions noted in the evaluation report. 2.1.1 OSHPD: The applicable OSHPD Sections and Chapters of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections and Chapters of the CBC are beyond the scope of this supplement. 2.2 CEC: The Icynene ProSeal. Icynene ProSeal LE. Icynene ProSeal H5 and Icynene ProSeal H5-0. described in Sections 2.0 through 7.0 of the evaluation report ESR-3500. comply with the 2019 CEC. provided the design and installation are in accordance with the 2018 International Building Code''' (IBC) provisions noted in the evaluation report. 2.2.1 Conditions of Use: In accordance with Section 110.8 of the 2019 California Energy Code. verification of certification by the Department of Consumer Affairs. Bureau of Household Goods and Services. must be provided to the code official. demonstrating that the insulation conductive thermal performance is approved pursuant to the California Code of Regulations. Title 24. Part 12. Chapters 12-13. Article 3. "Standards for Insulating Material."Certification can be verified with the DCA Bureau of Household Goods and Services using the following link to the bureau's Directory of Certified Insulation Materials: https://bhgs.dca.ca.gov/consumers/ti directory.pdf This supplement expires concurrently with the evaluation report. reissued January 2021. ICC-ES'Eraloarion Reports are nor to be construed as representing aesthetics or am other am ibures nor spec ificall)addressed,nor are the)r ro be construed ANs- as an endorsement of the subject of the report or a recommendation for its use There is no woman iv by ICC Evaluation Ser rice,LLC,express or implied,as , to am-finding or other matter in tins report,or as to any product covered by the report Copyright©2021 ICC Evaluation Service,LLC- All rights reserved Page 7 of 7