Loading...
HomeMy WebLinkAboutFile Documents.315 E Hyman Ave.0011-2023-BCOM (30) FLARE FIREPLACES WARNING: If the information in these � L5l. NJGR instructions are not followed exactlly. a fire or explosion may result causing property HOT GLASS WILL damage, personal injury or loss of life. CAUSE BURNS. DO NOTTOUCH GLASS — Do not store or use gasoline or other UNTIL COOLED. flammable vapors and liquids in the vicinity of NEVER ALLOW CHILDREN this or any other appliance. TO TOUCH GLASS. — WHAT TO DO IF YOU SMELL GAS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must • Do not try to light any appliance. be installed for the protection of children and other at-risk individuals. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a , ,p FLARE REQUIRES INSTALLATION BE neighbor's phone. Follow the gas =P �So PERFORMED BY AN NFI CERTIFIED INSTALLER, supplier's instructions. �° f OR A CERTIFIED FLAREAUTHORIZED • If you cannot reach your gas supplier, call z m INSTALLER.INSTALLATIONS THAT DO NOT the fire department. %meg' FOLLOW THIS INSTRUCTION WILL NOT BE COVERED BY WARRANTY OR SERVICED. — Installation and service must be performed by a qualified installer, service agency or the gas supplier. NOTICE INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. INSTALLATION AND SERVICE OF THIS APPLIANCE MUST BE PERFORMED BY QUALIFIED CERTIFIED NFI PERSONNEL OR CERTIFIED FLARE FIREPLACE DEALER. Massachusetts: The piping and final gas connection must be performed by a licensed plumber or gas fitter in the State of Massachusetts. Also, see Carbon Monoxide detector requirements on page 56. Modern Gas Fireplaces-Linear Fireplaces Fireplaces Installation Guide- SIT Proflame 2 RECEIVED Flare Fire p �1. [Flare Double Corner, Left Corner, Right Corner, Front, See-Through, Passage, and Room Det 4r}0/2023 v18.6 ASPEN 1311ILDING DEPARTMENT FLARE FIREPLACES TABLE OF CONTENTS SAFETY INFO AND WARNINGS 5 FLARE FIREPLACES—FRAMELESS IN EVERY WAY 7 SAFETY 7 CSA CERTIFICATION 7 MANUAL MODEL LIST&INFORMATION 8 FIREPLACE OPERATION 9 REMOTE CONTROL INSTRUCTIONS 9 IFC Proflame 2 Remote buttons: 9 Remote control specification: 10 Temperature indication display 10 Turning the system ON and OFF using the remote control 11 Remote Flame modulation 11 Room thermostat option 12 Smart room thermostat option 12 Fan Speed Control 13 Continuous Pilot Ignition/Intermittent Pilot Ignition(CPI/IPI) 13 Key Lock 13 Low battery power detection 13 SIT BATTERY BACKUP-OPTIONAL—SCREEN UNIT ONLY 14 PAIRING REMOTE WITH FIREPLACE RECEIVER 15 Initializing the system for the first time 15 Ignition Sequence 15 WALL SWITCH—OPTIONAL 16 MEDIA ARRANGEMENTS 17 FEATURE REMOVAL 18 SAFETY SCREEN REMOVAL 18 EXTERNAL TEMPERED GLASS REMOVAL—DOUBLE GLASS FIREPLACE 19 INTERNAL CERAMIC GLASS REMOVAL 20 SIDE GLASS TRIM REMOVAL!INSTALLATION—FLARE H&EH 22 REFLECTIVE BACK INSTALL 23 INSTALLATION STEPS 24 ACCESS PANEL 25 COMPONENT WHIP 25 SIZING RECOMMENDATIONS 26 INSTALLATION PREPARATION 27 FIREPLACE UNPACKING 27 FIREPLACE TELESCOPIC LEGS SETUP 28 LEG SETUP FOR FRONT AND SEE-THROUGH UNITS 29 LEG SETUP FOR CORNER UNITS RECEED 04/10/2023 2IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES UNPACKING CONTROL UNIT AND ACCESSORIES 31 FIREPLACE POSITIONING 32 LED LIGHTS 33 LED LIGHT INSTALL AND POWER 34 LED CONTROLLER AND REMOTE 35 OPTIONAL BLOWER KIT FOR SCREENED UNIT 37 VENT TERMINATION 38 VENT AND FIREPLACE SIZE 39 MINIMUM COMBUSTIBLE CLEARANCES FROM VENT 39 VERTICAL TERMINATION 40 VENT TERMINATION CLEARANCES 42 VENT RESTRICTOR SETUP 43 CHIMNEY PATH INSTALLATION AND PLANNING 44 FLARE 30/30H 45 FLARE 45/45H/45EH 46 FLARE 50/50H/50EH 47 FLARE 60/60H/60EH 48 FLARE 70/70H/70EH 49 FLARE 80/80H/80EH 50 FLARE 100/100H/100EH 51 POWER VENTING 52 ELECTRICAL CONNECTION TO THE PV SYSTEM 54 GAS INSTALLATION 55 GENERAL 55 USING A REDUCER TO DE-RATE YOUR FLARE FIREPLACE 57 ADDING THE FLARE FIREPLACES DE-RATING REDUCER 58 ORIFICE SIZE 59 GAS VALVE ACCESS DOOR 59 MANUAL GAS SHUTOFF 59 LIQUID PROPANE USAGE IN FLARE FIREPLACES 60 COMMONWEALTH OF MASSACHUSETTS 61 FLARE FIREPLACES-DOUBLE GLASS 62 OVERVIEW 62 DOUBLE GLASS-INSTRUCTIONS 63 POWER REQUIREMENT—ELECTRICAL REQUIREMENT 64 TELEVISION MOUNTING ABOVE FIREPLACE 64 TV INSTALL—FLAT EXAMPLE 65 TV INSTALL—LTYPEE RECE /ED 04/10/2023 3IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES TV INSTALL RECESS-45 DEGREE ELBOW ON TOP OF THE UNIT 67 TV INSTALL WITHOUT RECESS—MANTEL INSTALLATION 68 CLEARANCES 69 METAL FRAMING SPECIFICATIONS 69 WOOD FRAMING SPECIFICATIONS 70 CLEARANCES SPECIFICATION 78 MANTEL CLEARANCE 79 CLEARANCE TO SPRINKLER 80 HEAT RELEASES 81 AIR INTAKE 81 EXAMPLES OF HEAT RELEASES 82 SETTING UP YOUR FLARE FIREPLACE FOR ENHANCED OPERABILITY 83 KEEPING THE WALL ABOVE YOUR FIREPLACE AS COOL AS POSSIBLE 83 KEEPING YOUR DOUBLE GLASS AS COOL AS POSSIBLE 84 FLARE FRONT,SEE THROUGH,AND CORNER FIREPLACE CLEARANCE 85 Flat—side and isometric view 85 L shape—side and isometric view 87 Side Overhang Specification on Left, Right, &Double Corner Fireplaces 89 INDOOR/OUTDOOR KIT 90 OUTDOOR KIT INSTALLATION CONSIDERATIONS 90 OVERHANG REQUIREMENT 91 OUTDOOR KIT FRAMING AND FINISH 92 OUTDOOR KIT CLEARANCE TO NON-COMBUSTIBLE WALL 92 OUTDOOR KIT OPENING DIMENSIONS 93 WEATHER-PROOF YOUR OUTDOOR KIT CAVITY 94 BURNER DIMENSIONS 95 HOME AUTOMATION ERROR! BOOKMARK NOT DEFINED. ELECTRIC AND CONTROL 96 ELECTRIC DIAGRAM-SCREEN 97 DIAGRAM—DOUBLE GLASS AND POWER VENT 98 DOUBLE GLASS BOARD&LED LIGHT GUIDE 99 ELECTRIC DIAGRAM—PV SYSTEM 100 REPLACEMENT PARTS 101 MAINTENANCE 102 TORUBLESHOOTING 104 ADJUSTING YOUR AIR SHUTTER TO PREVENT SOOTING 104 APPENDIX 105 MAINTENANCE LOG 105 WARRANTY POLICY 106 RECEIVED 04/10/2023 4IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES SAFETY INFO AND WARNING WARNING ! If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. Installation and services must be performed by a qualified installer, service agency or the supplier. The direct vent system appliance must be installed as an OEM installation in manufactured homes (USA only), or an aftermarket permanently located, or a mobile home,where no prohibited by local codes and must be installed in accordance with Manufacturer's instructions and the Manufactured Home Construction and Safety Standard,Title 24 CFR, Part 3280, in the United States, or the Standard for Installation in Mobile Homes, CAN/ CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate.A conversion kit is supplied with the appliance. NEVER LEAVE CHILDREN OR ANY OTHER AT-RISK INDIVIDUAL ALONE WITH THE APPLIANCE. This appliance must be electrically wired and grounded in accordance with local codes,or in the absence of local codes, with National Electric Code ANSI/NFPA 70—latest edition or the Canadian Electric Code CSA C22.1 A 110-120V AC Circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes,when it is installed in locations such as bathrooms or near sinks. Due to high temperatures,the appliance should be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. State of California. Proposition 65 Warning. Fuels used in gas,wood-burning or oil-fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health &Safety Code Sec. 25249.6 RECEIVED 04/10/2023 5IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES WARNING ! Young children should be carefully supervised when they are in the same room as the appliance.Toddlers,young children, and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at-risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers,young children,and other at-risk individuals out of the room and away from hot surfaces. Proposition 65 Warning: Fuels used in gas,wood burning or oil-fired appliances, and the products of combustion of such fuels,contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health&Safety Code Sec.25249.6. In the State of Massachusetts,only a licensed plumber and gas fitter may install this product. See Note for the Commonwealth of Massachusetts. When an existing Category I heater is removed or replaced,the original venting system may no longer be sized to properly vent the attached appliances. Instructions shall also indicate effects of an improperly sized venting system (formation of condensate, leakage, spillage, etc.) and shall specify the following test procedure. WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow the steps outlined below for each appliance connected to the venting system being placed into operation could result in carbon monoxide poisoning or death. The following steps shall be followed for each appliance connected to the venting system being placed into operation, while all other appliances connected to the venting system are not in operation: 1) Seal any unused openings in the venting system. 2) Inspect the venting system for proper size and horizontal pitch, as required in the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code, CSA 8149.1 and these instructions. Determine that there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause an unsafe condition. 3) As far as practical, close all building doors and windows and all doors between the space in which the appliance(s) connected to the venting system are located and other spaces of the building. 4) Close fireplace dampers. 5) Turn on clothes dryers and any appliance not connected to the venting system. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they are operating at maximum speed. Do not operate a summer exhaust fan. 6) Follow the lighting instructions. Place the appliance being inspected into operation. Adjust the thermostat so appliance is operating continuously. 7) Test for spillage from draft hood equipped appliances at the draft hood relief opening after 5 minutes of main burner operation. Use the flame of a match or candle. 8) If improper venting is observed during any of the above tests, the venting system must be corrected in accordance with National Fuel Gas Code, ANSI Z223.1/NFPA and/or Natural Gas and Propane Installation Code, CSA B149.1, 9) After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas fired burning appliance to their previous '► conditions of use. RECEIVED 04/10/2023 6IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES FLARE FIREPLACES — FRAMELESS IN EVERY WAY Flare Fireplaces is where innovation, quality and luxury come together to form innovative ideas. By combining superior raw materials, contemporary design, creative technology, and a frameless way of thinking,we have created a full line of direct-vent fireplaces that are luxurious, simple to operate, and efficient. Our modern gas fireplaces are distinguished by their clean linear design, superior built quality, and unique features. SAFETY CSA CERTIFICATION All our fireplaces are tested and have been certified to meet stringent CSA guidelines, ensuring optimum quality, safety, and efficiency. All our fireplaces have been certified and tested to work with Natural Gas or Propane. Certification Information: CSA File # 263124 CSA/ANSI Z21.88-2019 • CSA 2.33-2019-Vented Gas Fireplace Heaters CSA CLASSES: CLASS 2901 84/CLASS 2901 04 All fireplaces are rated for commercial and residential use. (r."—)tSIGN Cpic) ro (4) OCERTIFIED C US FR T i o v0 The CSA Mark The Canadian Standards Association (CSA) is a nonprofit association serving business, industry,government and consumers in Canada and the global marketplace. Among many other activities, CSA develops standards that enhance public safety. A Nationally Recognized Testing Laboratory, CSA is familiar with U.S. requirements.According to OSHA regulations,the CSA-US Mark qualifies as an alternative to the UL Mark. Here are some areas where CSA standards are applied: • Canadian Electrical Code, Part III-Outside Wiring • Electrical Engineering Standards • Electromagnetic Compatibility RECEIVED 04/10/2023 7IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES MANUAL MODEL LIST & INFORMATION The Following manual should be used for the following Flare Fireplaces Models: • Flare Front 30-100"—16" (R), 24" (H),30" (EH) • Flare See-Through 30-100"—16"(R),24" (H),30" (EH) • Flare Corner Right&Left 30-100"—16"(R),24" (H) • Flare Double Corner 30-100"—16" (R), 24" (H) • Flare Room Definer 45-100"—16"(R),24" (H), 30" (EH) All models share the same gas valve system, remote,gas connection, and glass type,simplifying installation and operation. All warnings and instructions apply to all models. Refer to the model's name for specific model,clearance and installation information. Flare Fireplaces should only be connected to M&G DuraVent or ICC 4x6 or 5x8 venting system. Refer to the specific appliance model and size to determine vent size (Gas specification table)and chimney pathway requirements (Chimney path installation&planning table). For detailed chimney installation information please use the M&G DuraVent direct vent installation manual:http://www.duravent.com For details on ICC direct vent installation, please use the ICC installation guide. http://icc-chimney.com/en/exceldi rect-support This product is listed to ANSI standards for"Vented Gas Fireplace Heaters"and applicable sections of"Gas Burning Heating Appliances for Manufactured Homes and Recreational Vehicles", and "Gas Fired Appliances for Use at High Altitudes". Installation MUST comply with local, regional, state,and national codes and regulations.Consult insurance carrier, local building inspector,fire officials or authorities that have jurisdiction over restrictions, installation inspection and permits. This installation must conform to local codes. In the absence of local codes,you must comply with the National Fuel Gas Code,ANSI Z223.1-latest edition in the U.S.A.and the CAN/CGA B149 Installation Codes in Canada. Improper installation,adjustment,alteration, service, or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified service technician,service agency or your dealer. .!►� FLARE REQUIRES INSTALLATION BE OSP 16 PERFORMED BY AN NFI CERTIFIED INSTALLER, 00 • 9 OR A CERTIFIED FLARE DEALER. O INSTALLATIONS THAT DO NOT FOLLOW THIS iNSTITU'�� INSTRUCTION WILL NOT BE COVERED BY RECEIVED WARRANTY OR SERVICED. �► 04/10/2023 8IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES FIREPLACE OPERATION REMOTE CONTROL INSTRUCTIONS IFC PROFLAME 2 REMOTE BUTTONS: - Main ON/OFF switch - Main Burner Flame Modulation 6 Levels Blue Back lit LCD display - Continuous or intermittent pilot mode (Intermittent is default) On/Off Key Thermostat Key Up/Down Arrow Key - Thermostat or smart thermostat functions. Mode Key - Accent light modulation 6 levels (NOT USED). - Mode Key (Flame Height, Lights, Smart Lock, Auxiliary Fan On/Off) Key Lock Transmission - Low battery alarm o� Room Thermostat OF °C Temperature On/Off/Smart I ON 1.111 SMA J CPI mode — (Optional) Set Point Temperature/Level/State MUST BE ON AUX Flame On 6 Levels6 • Not used MAX MAX MAX Not used RGB LED Control RECEIVED 04/10/2023 91Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES REMOTE CONTROL SPECIFICATION: - Need 4.5 voltage supply. - 0-50 °C ambient temperature rating. - 315 MHz radio frequency. ti TEMPERATURE INDICATION DISPLAY - When the system is turned off the LCD screen will display the current room temperature in Fahrenheit (°F) or in Celsius (°C.) - To change from Fahrenheit (°F) to Celsius (°C) or vice versa press the thermostat key and the mode key at the same time. oC ■ of • UMW ■ RECEIVED 04/10/2023 10IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES TURNING THE SYSTEM ON AND OFF USING THE REMOTE CONTROL ■_• • °F With the system OFF, press the ON/OFF Remote Key. The remote LCD will then j show other icons.At that time,the module will activate the appliance and a single U U beep from the receiver will confirm reception command from the remote When the system is ON, press the ON/OFF remote key,the remote LCD will show the room temperature icon, at the same time the module will shut off the appliance. F •SMART ■ ■ For information on using the remote and wall switch, click here. •=M M=• I■■I ID it=D I I ■■=■ m MAIL REMOTE FLAME MODULATION The Proflame 2 has 6 levels of modulation. ■�=r�•F ■m■G F When the system is ON the flame level will be ■s •▪•�� at the maximum level. ON ILI - gm' ■■_■ By pressing the down arrow key once it will :�■j�� reduce the flame height by one step. —• ma Continued pressing of the down arrow will 1 t result in the unit TURNING OFF. To return to T normal fireplace operation use the up-arrow I I key to increase the flame height to HI. ■ma mime•F moms■=■0 F ■■ ■■ ■■.= . .=■ oN II I ON II ■■l=■ ■■_■ • • � 1 II= ■ If the up arrow has been pressed while the system is ON, but the flame is OFF the flame I will come ON in the high position. MAX RECEIVED 04/10/2023 11IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES ROOM THERMOSTAT OPTION ROOM TEMPERATURE The Remote control can operate as a room _- thermostat. The thermostat can be set to a desired I°F °F temperature to control the room temperature. To im ON activate this option, press the thermostat key. The thermostat icon on the LCD screen will display the �M I11•M II1 thermostat status is ON.The user can then set a suitable Ali�I� Ali ; temperature for the space. To adjust the desired temperature,use the up or down arrow until the desired temperature is displayed on the remote LCD screen. SET TEMPERATURE SMART ROOM THERMOSTAT OPTION The smart thermostat option will adjust the flame height — depending on the set temperature that has been set by the a ��� °F °F user. When the room temperature gets close to the set SMARTI ■ temperature the smart thermostat function will modulate SIMI MGM the flame down. I■■1 It ilk! BEI I I To activate the smart thermostat function, press the ■ thermostat key while the appliance is on until the word SMART appears beside the icon of the thermostat. Nux To adjust the set temperature, press the up or down arrow keys until the desired temperature is displayed on the LCD. Note that:when the smart thermostat is activated,the flame level modulation is not activated. RECEIVED 04/10/2023 12IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES FAN SPEED CONTROL This feature is not used with the Flare fireplaces. ■m: ■°F /'�{ ■m■ ■o F • itON I I •ON I I.Q II• I11 •1I ■ I•�r u minium 1 * 1 1r� CONTINUOUS PILOT IGNITION/INTERMITTENT PILOT IGNITION (CPI/IPI) ■ml 1*F Imo :°F By default, the Flare Fireplace is setup for IPI operation, but this can be 4 •ON ON 1 1 changed to CPI on screen units only. When the system is OFF pressing the 11.11 rm. ■ Mode key to index to CPI mode icon. Press the UP arrow will select the CPI irUI Li mode(but it is still not activated.)There is also a switch on the CPI/IPI that is located on x5 port in the module. Pressing down arrow key will activate the IPI mode at the same time turn the IPI/CPI switch in X5 port on the module. A single beep will confirm the command. KEY LOCK To avoid unsupervised operation of the remote control this feature has been created.To activate this feature,press the mode and up arrow at the same time.A lock icon will appear in the LCD screen.To 40.®1 I°F deactivate this feature, press the mode and up arrow at the same time. LOW BATTERY POWER DETECTION The life of the remote batteries depends on - Battery quality - Number of ignitions of the appliance - The number of actions on the remote control When the remote battery is low an empty battery icon will appear on the LCD Screen p CAUTION: DO NOT USE a screwdriver or other metallic object to remove the batteries from the battery box!This could cause a short circuit to the system. E AEI ED 04/10/2023 13IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES SIT BATTERY BACKUP -OPTIONAL — SCREEN UNIT ONLY Batteries—Remote • 4 x AA(alkaline recommended). • Low battery indicator on handsets with display. • Battery replacement is recommended after 1 years. Batteries—Receiver • 4 x 1.5 V"AA"(alkaline ONLY). • An AC Mains Adapter may be connected in addition to batteries. • Without using a mains AC adapter, battery replacement is recommended at the beginning of each heating season as part of the yearly service check. • Battery pack to be used with screen units only.Will not work on double glass units. • Battery pack attaches to X5 cable at black end cap. 07) ill - ,=. ECEIVED 04/10/2023 14 I P a g e ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES PAIRING REMOTE WITH FIREPLACE RECEIVER Your remote will come paired with the fireplace receiver to allow for operation out of the box. In the event of a remote or receiver replacement, use the following procedure to pair the remote with the receiver: INITIALIZING THE SYSTEM FOR THE FIRST TIME - Install 3 AAA type batteries in the remote battery bay located on the remote back. - Press the SW1 button on the module see the following figure, the module will beep 3 times to indicate that it is ready to synchronize with the remote. - Press the ON/OFF button in the remote,the module will beep 4 times to indicate that the remote and the module are synchronized to each other. " AI ®� ® fr I - SW, . lii •�.�. 0000 LI IIIIIIIIIII "--'' FUU SW1 =Programing Button IGNITION SEQUENCE Starting from OFF, press the remote power button. Four seconds after it is pushed the SIT module will send spark to the pilot hood, and spark for 60 seconds. If there is no flame ignition during the first ignition sequence,the SIT module will stop sparking for approximately 35 seconds and then begin sparking again.The second attempt will spark for 60 seconds. If there is no positive ignition after the second sequence the SIT module will go into a Lock Out and the LED Indicator Light will blink three times in intervals until the system is reset. -Ignition sequence will spark for 60 seconds,followed by a 35 second wait,60 second spark and then lock out if flame is not ignited. -The lock out will blink on the LED indicator light will blink three times. Reset Using the Transmitter ON/OFF power button:Turn the system off by pressing the remote power button.After approximately 2 seconds press it again Low Battery Condition(<4V) Remote Control: Battery icon will appear on LCD remote control display. Replace batteries. Low Battery Condition(<4V) Battery Backup: Red LED Indicator will blink(1)time in intervals. Low double-beep emit- ted from SIT control module when it receives an ON/OFF command from the remote control. Replace Batteries. Pilot Flame Error Condition: Red LED Indicator will blink(2)times in intervals. Contact your dealer if this occurs. System Lock Out Condition: Red LED Indicator will blink(3)times in intervals. Make sure gas is turned on and sensor is not shorted. Follow Reset Using the Transmitter ON/OFF power button instructions above. RECEIVED 04/10/2023 15IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES WALL SWITCH — OPTIONAL In case of losing the remote control or empty batteries,there is another option to control the fireplace which is located on the X8 port of the IFC module which the WALL SWITCH.The following operation can be done from the wall switch: - Turn ON fireplace - Turn OFF fireplace T. , —Jr �c° 1 .vim U w q II rcTs�� � a 2, �/ f Note: Flare Fireplaces supplies each fireplace a wall switches and a remote control to control the unit. Please note, only one device should be used in a cycle of powering the unit on and off. If you utilize the remote .....'_ control to power the appliance on, use the remote to also power the unit off. \I Trying to utilize different methods in a cycle could result 1': in one method failing to control unit until appliance has - - been powered down and the cycle ended. SIT wall switch can be run with up to 100 FT of wire. RECEIVED 04/10/2023 16lPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES MEDIA ARRANGEMENTS Flare Fireplaces can be equipped with different media types. Follow the instructions below for information on how to add and arrange media in your Fireplace.Click here for Media Calculation Guide • Do not place any type of media on the pilot or in front of the pilot. Keep 1"distance from the pilot to allow correct operation of the pilot. • Media can be put over the Flare burner.Avoid placing media over the main burner ports as it may disrupt flame in case of a clogged port.Avoid placing driftwood arching over burner, instead place in front or behind. • If using media that was not supplied by Flare Fireplace, make sure that the media is certified/suitable to be used in direct vent gas fireplaces. • Keep the pilot front cover view open to be able to view the pilot spark and flame from outside. • Fireglass: a. 'A"or%" Fire Glass may be used. b. When the fireplace viewing window is open,and media is placed, make sure Fire Glass does not fall on the ceramic glass lower frame as that may cause breakage when putting back the ceramic glass. c. Make sure pilot is clear of any Fire Glass particles. d. Flare Fire Glass can be put safely into the firebox.Avoid overloading the burner with Fire Glass, specifically over the main burner ports. • Maintain minimum distance of'A"from media to the fireplace glass panels. • Use the manual for instructions on how to remove, replace,&arrange the fireplace glass media PROPER DRIFTWOOD PLACEMENT IMPROPER DRIFTWOOD PLACEMENT 111011‘11 1111 1 Illir Nu...-- --'i Ceramic Pebbles Fireglass ti EV/ ‘ • it c' ;k- 'i. r=s • j . e : 11 _ I CHOKING HAZARD! Ensure that the fireplace area is clear of fire glass particles as these could be ingested by small children.Vacuum area after installation RECEI D 04/10/2023 17 I P a g e ASPEN BUILDING DEPARTMENT FLARE FIREPLACES FEATURE REMOVAL SAFETY SCREEN REMOVAL Follow the instructions below for safety screen removal. PLEASE NOTE:Safety screen may be shipped separately from the appliance. I The barrier is designed to reduce the risk of burns from the hot viewing glass and is provided with this appliance. It must remain installed for the protection of children and other at-risk individuals. Do NOT operate the fireplace without the safety screen barrier. Front,See Through,and Corner Units • Safety screen removal requires no tools. • Push the top frame of the screen up until it clears the bottom of the opening. • Tilt the bottom of the screen out and pull down so the top frame clears the opening. • POW' • &VC sot- RECEIVED 04/10/2023 181Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES EXTERNAL TEMPERED GLASS REMOVAL — DOUBLE GLASS FIREPLACE Follow the procedure below to remove and install back the fireplace external glass(double glass fireplace configuration). Note: Suction cups are needed to remove the glass. Warning!Turn off the fireplace and allow time for the unit to cool before proceeding. Caution:The glass is very fragile and should be handled with care. Warning! Double glass fireplace should NOT be operated without the external glass • Confirm lock screws have been removed during install (should be done once,during install only). • Attach glass suction cups to the glass. Use more than one suction cup if needed (any unit above 45"). • Using suction cups, slightly push in the external glass top edge. • Once glass has been pushed,slightly lift the glass to clear bottom part of the glass. • Remove the glass and place in a secure location. Install back external glass • Removal •_` ..'" .r r w_ e Use suction cops •. Pont,glass naxl up Clear boltan glass fist • Attach glass suction cups to the glass. Use more than one suction cup if needed (any unit above 45") • Place upper edge of the glass in position and push latching trim. • Once trim has been pushed in,slide glass top in position. • Tilt in bottom edge of the glass in position as you are lifting the glass up. • Glass is now secure in place. No bolts are needed to lock the glass. 77 \\\ �� �. .. Push lop ton wet the pass Side n Impart fist No manual bow need RECEIVED 04/10/2023 19IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES INTERNAL CERAMIC GLASS REMOVAL Follow the procedures below to remove and install the internal ceramic glass(double glass fireplace configuration). Warning!Turn off the fireplace and allow time for the unit to cool before attempting to remove the glass. CAUTION:The ceramic glass is very fragile and should be handled with care. J CAUTION: Do not operate the appliance with glass removed,cracked,or broken. Replacement of the panel(s)should be done by a licensed or qualified service person. /UNITS LARGER THAN 45" REQUIRE TWO SUCTION CUPS AND TWO TECHNICIANS Step 1—Remove the bottom, left, and right magnetic trim pieces, place in a secure location to prevent damage. Step 2—Locate and loosen the hand screws within the top frame of the fireplace.These will loosen the top butterfly trim, releasing the glass from the inner gasket, preparing it for removal. Step 3—Locate and loosen the hand screws,on the right, within the frame of the fireplace.These will loosen the right trim which can be removed and set aside to prevent any damage. Step 4—Locate and loosen the hand screws,on the left,within the frame of the fireplace.These will loosen the left trim which can be removed and set aside to prevent any damage. Step 5—Locate and loosen the hand screws,on the bottom,within the frame of the fireplace.These will loosen the bottom trim which can be removed and set aside to prevent any damage. Step 6—Attach your suction cup(s)to the inner layer of glass.Once secure, lift,clearing the bottom frame. Pull out and down to clear top frame, and lay glass on a soft flat surface in a safe location. WHEN REINSTALLING YOUR GLASS DO NOT OVERTIGHTEN THE HAND SCREWS SECURING THE TRIM AGAINST THE GLASS. Step 1 Step 2 it `, I I . _4) ii _. , . 4,,- : - ^, .. 11 it . . .11-.:::....... .„::: ::.:„..:::.;. ^ • a . - • ED 04/10/2023 20 I P a g e ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES Step 3 Step 4-1 1114 IF ai. i I..: - . -11 ._ .., ; ____ . __ '' . __,..,„ _.. , ... ,, i , „. .. . ... 1- . . 7,`‘ . _ ' �\ Step 4-2 IF 1 .. ., ii . 411 Hf `.-:-.: i ..".;;E:::::-:=. - -__ -./.'-'-'''''''''..1 ' ,1 • i ems..-- I Al When putting back the glass,DO NOT overtighten the bolts or glass may break. • Use step 4—1 for putting the glass back. • Glass trim screws should be closed hand tight. DO NOT overtighten the bolts or glass may break. RECEIVED 04/10/2023 21IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES SIDE GLASS TRIM REMOVAL / INSTALLATION — FLARE H & EH The additional side trim piece for the H & EH models is installed differently than the standard height unit's side trim pieces&has additional steps required to remove&apply it successfully. All work should be done with a cold fireplace,fireplace appliance turned off and manual gas valve shutoff. Unplug the fireplace from any electric power(Double Glass Units) Step 1: Using a drill, untighten the screw that is located at the right The below picture shows the right-side glass trim. top of the trim side as shown in picture below. iii 1 ; (V, 4 1 1 a IP I \ , ,„„ 1111 - - \\ IJJUJJ+1.. �11111....\\\\\ .1J111111i� Step 2: Move the right trim glass to the left as shown Step 3: Remove the lower side of the trim slowly as in picture below. shown in picture below. 5 of 1 ="' 1 ,.. . . , . '. 7.:. ::: I�J I ,r= �,' -v W/ ' HU - -' 111N - -- y/,/////////////IN11 LI I I 111111111N\\\ fr. . RECEIVED 04/10/2023 22IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES REFLECTIVE BACK INSTALL The Flare Fireplace may be ordered with a reflective ceramic glass backing.The ceramic glass is tinted black to create a reflection when the fireplace is running.The ceramic glass will enhance and protect the fireplace look and is easy to clean. The reflective back is shipped outside the unit, inside a sleeve with the other glass panes. It should be mounted at the back of the fireplace, placed in the gap between the fire bed (shown yellow below)and held by the top mounting brackets(red circle). • Carefully carry the reflective back using suction cups,and place at a 45-degree angle as shown below. / • Screw the mirror clamp as shown below,make sure you do not over-tighten the screw,&leave 1"of the screw length out. 1 • N-/ 41 .00.0. 1111111. RECEIVED 04/10/2023 23IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES INSTALLATION STEPS 1. Prior to starting the installation,make sure you read and understand all WARNING information in the manual.Do not start the installation if you are unclear about any of the installation related subjects. 2. Determine the following: • The vent system configuration to be used based on the fireplace location. Follow the manual venting section(Chimney path installation&planning tables)to determine the venting requirements and setting. Note:Venting requirements are model specific. Note: Make sure the vent requirements are supported by the Flare manual and installation instruction. • Clearance requirements from combustible and non-combustible materials. Follow the clearance instruction and example in the manual. Note:Clearance instructions and examples are model specific. • Gas supply piping. • Confirm if the fireplace is going to operate using Natural Gas(NG)or Propane. Use the attached product label to confirm the fireplace is set for the expected gas type. • Electrical wiring requirements. • Framing and finishing details. 3. Unpack the fireplace box,adjust telescopic legs and place in the upright position. Follow instruction for fireplace unpacking. 4. Put the Fireplace in the desired location.Verify clearance to non-combustible and combustible materials. Follow the clearance instruction and example in the manual. 5. For LED units,connect LED system and test LED. 6. Attach the units back bracket to the wall framing. 7. For double glass units only: remove glass locking screws and discard. 8. Adjust Fireplace vent restrictor based on vent configuration and planning guide. Document vent restrictor setup here: 9. Connect vent system to the Fireplace. 10. Connect gas (Gas connection section) line to the Fireplace and verify gas inlet and outlet pressure. Measure and document gas pressure here: Inlet W.C. 11. Confirm if adjustments for high altitude are needed (Installation at above 2000 Ft from sea level). 12. Connect electrical wiring for applicable units. 13. Insert and place Fireplace media. Use media arrangement guide from the manual. 14. Verification of: • Ignition and pilot system. • Burning and flame. 15. Complete framing and wall cover. Read all the instructions before starting the installation.Follow these instructions carefully during the installation to ensure maximum safety and benefit. Follow the Steps above to insure proper installation of the Gas appliance. WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation.DO NOT install damaged,incomplete or substitute components. RECEIVED 04/10/2023 24IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES ACCESS PANEL The Flare Fireplace gas valve and control system is on a component "whip" that can be stretched up to 50" from the middle of the fireplace and placed next to the access door location. Do not place the gas valve or controls above the level of the burner. Keep the area storing the fireplace components clean and free of unnecessary debris. If the fireplace sits too low on the floor, the controls must be placed outside the non- combustible zone or insulated from the heat from the fireplace. The access door can be placed on any side of the fireplace, below the non-combustible line. The use of a 12"x12" access door is highly recommended. If no access door is installed, it's possible to access the gas valve from inside the fireplace by removing the glass. The access door can also be used as a lower air intake (FOR A DOUBLE GLASS INSTALLATION) if it's perforated, and the open air-flow requirements are maintained. The access door can be concealed in many ways, such as HVAC vent cover or removable piece of finishing material attached with magnets or screws to the framing. COMPONENT WHIP All Flare fireplaces ship with the components attached to a 50" whip, centered, at the underside of the fireplace. This allows an installer to drag the components to the far left, far right, behind, below, or directly underneath the fireplace. Opening unlimited possibilities for implementing access based on the unique project parameters and the 50" component whip. COMPONENT OVERHANG BASED ON SIZE OF FIREPLACE 30" Fireplace: 35"On left and right side 45" Fireplace: 27.5"On left and right side 50" Fireplace: 25"On left and right side 60" Fireplace: 20"On left and right side 70" Fireplace: 15"On left and right side 80" Fireplace: 10"On left and right side 100" Fireplace: NO OVERHANG COMPONENT < > RE ..EIVED 50" WHIP 04/10/2023 25IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES SIZING RECOMMENDATIONS Access panels will come in all different shapes and sizes, below are some minimums outlining what is important for creating meaningful access. These are recommendations, not requirements. Use best judgement for sizing based on the unique design parameters of the project. EXAMPLE 1—REMOVEABLE FINISH PIECE A ^—_ T EXAMPLE 3 -DOOR 44 18„ T I 12" EXAMPLE 2—LINEAR LOUVERED GRATE A 4 12 > < 24„ > < 12 > EXAMPLE 4—REMOVEABLE LINEAR TOE KICK < > REMOVEABLE L-SHAPED TOE KICK— LENGTH OF FIREPLACE OR CAVITY— HELD BY SCREWS OR MAGNENTS POSSIBLE POSITIONS REMOVEABLE STONE FINISH EXAMPLE _ _ ; -- I__ r RECEIVED 04/10/2023 26IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES INSTALLATION PREPARATIO'� FIREPLACE UNPACKING Follow the instructions below for unpacking the unit: • Check the packing and confirm there is no external damage.If damage exists,please notify Flare Fireplaces immediately. • Remove the top wood studs and pull the external carton box up. • Please do not remove the blue wrap completely at this stage. • Leave the fireplace placed on the pallet for the next step: Fireplace legs setup. �_- o-_�.- •, rerrecuonnuppycom' 1 1 - 5; r i T = 1 ,— f.'1Cr'ir ;Oft - i , --r-:;:x/W ,,- vje-%'---;"‘44-::7,471'" -.,t.,.. 4-;;--1, -- \ . . . _, )111 . -___ _ . RECEIVED 04/10/2023 27IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES FIREPLACE TELESCOPIC LEGS SETUP The fireplace legs will need to be set up once box is removed.The legs can be configured so that the bottom of the glass will be between 10"-19"above the floor.This means the bottom of the fireplace will be 4"-13"above the floor. Follow the steps below for telescopic legs setup prior to final positioning of the fireplace. On Corner units(Flare-RC/LC/DC/RD)front legs will need to be assembled. I Fireplace must NOT be installed without telescopic legs extracted to a minimum of 3". Installing fireplace without telescopic legs is a fire hazard. Installing the Fireplace without legs(sitting on the fireplace frame) may bend the frame&cause glass breakage. Fine Tuning After extending the legs to the desired length, use the wrench included to fine tune the feet so that the fireplace is level. ,'Tr • � a N .rYs Note that the feet are intended for minimal adjustments and not to be extended completely for � i �L"It extra height. Doing so will make the fireplace unstable. ,ate The Yc @?are used for Ms ganuolg o zhogsod on&Ttr adju ted once gThe v1178poage ll Zg8ncloogo Oprpkg or®xte.n:d ng ps_llso boo much woo' mos as Vkapkgs fro L ©oms aflagaL ll • RECEIVED 04/10/2023 28IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES LEG SETUP FOR FRONT AND SEE-THROUGH UNITS • Step1-Release the pin. • Step2-Release the 2 screws from the leg. • Step 3-Extend the telescopic leg to the desired length, minimum 4" (That will set the fireplace 10"from the bottom of the glass to the floor). • Step 4-Retighten the three screws to secure the telescopic leg in position. Note that the top pin inserts into the holes only for alignment.The two bottom screws tighten down on the legs. • Step 5-Repeat Steps 1-4 for each on the fireplace so that they are all extended to the same length. • Step 6-Stand the fireplace up and fine tune the feet with the wrench included so the fireplace is level.Open the screws to raise the fireplace.Close the screws to lower the fireplace. Step 1 Step 2 I • i IJ c. .. • 4 .,, --s %to" -- . iiiiii6,-. ,..„..-----_—;- -.--..----, 11. I. r ' v. - r r Irk ...r 1 ` Y� _ , ,,-\ .. 41 ' 'An - X--_-_ndliiiiiiiliNgi" Step 3 Step 4 RECEIVED 04/10/2023 29IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES LEG SETUP FOR CORNER UNITS Included are 4 screws, 2 adjustable legs, 1 foot for fine tuning,and 1 special wrench for adjusting the feet while the fireplace is standing. • First, identify the correct order to connect the legs.The first adjustable leg that attaches to the fireplace has Rivnuts as seen in the image below.The second adjustable leg has a place for the foot to be screwed in on the bottom as seen in the images below. Rivnuts Rivnuts -----4 III - • • • • • *:;-71;.- eiooeosees ...,,,,,,. R � h M Legs attached to the fireplace Adjustable legs 2ry Fine tuning • Next, determine which holes to insert the 4 screws so that the fireplace will stand at the desired height after the foot for fine tuning is also screwed in. • Insert the 4 screws into the holes and Rivnuts beneath and tighten. Screw in the foot so that it can later be adjusted to slightly raise or lower the fireplace. • Configure remaining legs to the same height. s- :6:9 to • • • • • ' evl a), • • • • • •( ).b.„ imimmiirer__ ______ _. . ispoompar-- -nir-- ___ _ _ _ 2, --_. 'Ir Legs attached to the fireplace Adjustable legs 21r. Fine tuning • Stand the fireplace up and fine tune the feet with the wrench provided so the fireplace is level. Open the screws to raise the fireplace. Close the screws to lower the fireplace. .1.. , e leve ers are use• o `'4 e tuning & should only be NOTE: Please note all corner ' .djus •nce the fireplace is units must have their telescopic standing. legs attached to achieve the .` ?'.y,,,� minimum height required to the .. Opening or extending the" '' underside of the fireplace. l 11111011P ii— egs too much will cause the fireplace to become unstable ED 04/10/2023 30 I P a g e ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES UNPACKING CONTROL UNIT AND ACCESSORIES Unpack the accessories(remote, power adapter&wall switch).The gas valve, receiver,control module(for double glass units)will remain wrapped until first test of unit. • Place accessories (white bag) in a secure location. • The control unit(gas valve and receiver)is attached to the fireplace on an "umbilical cord". Once fireplace is moved to its final location the control unit can be put close to the service access door. I 1 ic : - iiiiii"-- _ i ____..1 Aftlimir ' _ fi / i ' It\- ____ ._....sie t ',AP .fir+« Gas valve and receiver: ***GAS VALVE WILL COME WRAPPED,ONLY TO BE OPENED FOR UNITS FIRST FIREUP f r e 44# 1 w / .y • I ' � ( r ` ,\ ��r .\ ... i % _ .lie r Sic LIS�1�9 ., o f i . It+ 1IIhuJIPhhIh1 ! . ? F F By^sa an Exhaust ADjjjJ 1.1111111111111 RECEIVED 04/10/2023 31IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES FIREPLACE POSITIONING Once Fireplace has been set to the upright position, it can be moved to its final installation location. • Make sure the control unit is secure and not dragging on the floor during transport and positioning. • Unit should remain on the pallet during transport inside the site location. • When positioning the fireplace,take into consideration the clearance requirements and framing. Use the manual clearance guide for more details. • Attach the fireplace top brackets to the metal stud in the back to secure the fireplace in place.The bracket length can be adjusted by releasing the screws on the top. a 111. MEI wommm=m444414 Fireplace should remain on the wood pallet when carried to final installation location. Do not attempt to use a pallet jack or any other moving tools if the unit has been removed from the wood pallet as it may harm the fireplace components under the unit. • Make sure to use only non-combustible material in case top the brackets need to be extended to connect to the back or sides. RECEIVED 04/10/2023 32IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES LED LIGHTS The Flare Fireplace can be ordered with optional multi-color interior RGB LED lighting.The lights allow perfect flames to be viewed across a bed of illuminated crushed glass,or any other direct vent approved media option. RGB LED—The multicolored option is controlled by a remote for the color selection.Once the color has been selected by the operator,the LED memory will remember that color for the next time the unit is turned on. i I ► •1111111 • a LED Operation: Option 1—Double Glass unit • LED power is connected to the Flare control system (Labeled in picture above as LED Power Outlet,and below as Connection C) • LED will turn On and Off with the fireplace,controlled by the fireplace remote or wall switch. • Color control can be done by the LED remote. • Once a color is selected,the LED remote can be stored away. • LED to be switched Off when fireplace is turned off. • LED cannot be switched on when fireplace is off. Option 2—Screen or Double Glass • LED can be connected to independent power source, home automation system or smart outlet. • LED can be turned ON/OFF from LED remote, independent from the fireplace. • LED can be turned on, even when fireplace is off. RECEIVED 04/10/2023 33IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES LED LIGHT INSTALL AND POWER It is best if LED lights are connected and tested during the initial stages of installation to allow easy access under the unit(before the wall finishing material is done). Testing the LED light requires a 110V power source. Installation steps: 1. Remove all LED components from the shipping bag. 2. Components are pre-connected prior to shipping. Connect LED connectors(points A)to the fireplace using the quick connect connectors. 3. Connect LED control system to the power supply(point B) 4. Connect LED Power supply to an external power source(point C). Do not connect the LED to the Flare control LED plug at this point. Use the LED remote to turn the LED on the LED system. Once testing is done,connect the LED power adapter to final power source(Point C),Option 1 or Option 2 as detailed in the previous page. Power outlet on the Flare control is optional for LED ONLY I Flare Fireplace A . LED connector B . LED DC control power plug LED Light .l LED Controller LED Power Adapter • • • • LED Light A A A . LED connector C . 110V Power input LED Remote 11.117:11h1111111F.PE.EAAO/Fre n E., e 1111 1 �..ro. - � Lt _a RECEIVED 04/10/2023 34IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES LED CONTROLLER AND REMOTE e ,,, LED Remote a a H �a y o , SIT RECEIVER i1 1 LED POWER n 1'1 LED Controller Point C CABLE IS POST V LED Light 1 LED Light 2 BLACK CA. ATIVE - Product Specification The Flare high-performance RGB LED touch remote controller adopts the most advanced PWM control technology.This remote controls all RGB LED products with 4 lines of circuits(COMMON ANODE),owning 64 thousand colors&20 automatic changing modes to choose from. RBG Strip is using 24V DC power adapter. MATERIAL 110x52x2Omm POWER AAA Battery *2pcs REMOTE MATERIAL ABS Multicolor Printing& UV FABRICATION PROCESSING Varnish SIZE 85x45x23mm WORKING VOLTAGE DC12V^'24V CONTROL WAY RGB 3 CHANNELS CONTROLLER MAX LOAD PER CHANNEL 6A OUTPUT CONNECTION COMMON ANODE TELECONTROL DISTANCE 30 METERS PROGRAMS 20 KINDS or` rtw CABLE IS POSITIVE LED POWER — - TOUCH SCRENLED v ~ LED Strip 24V or 12V R ~ BLACK CABLE IS NEGATIVE Y cable :�...�.r.- ArOromt 1H RECEIVED 04/10/2023 35IPage ASPEN BUILDING DEPARTMENT AFLARE FIREPLACES 1.ON — 0 2.OFF 4. Indicating light e -3.Color ring 11)5.Speed+ 6. Brightness+ ,� y' 9. Mode+ ii 7.Brightness- 10. Mode- 8.Speed- Mode selection and remote BRIGHTNESS NUMBER MODE STATE SPEED STATE 1 STATIC WHITE ADJUSTABLE UNADJUSTABLE 2 WHITE COLOR GRADUAL CHANGES ADJUSTABLE ADJUSTABLE 3 ALL COLORS GRADUAL CHANGES ADJUSTABLE ADJUSTABLE 4 RED/GREEN/BLUE 3 COLORS GRADUAL CHANGE ADJUSTABLE ADJUSTABLE 5 7 COLORS JUMP TO CHANGE ADJUSTABLE ADJUSTABLE 6 3 COLORS JUMP TO CHANGE ADJUSTABLE ADJUSTABLE 7 RED/GREEN JUMPS TO CHANGE ADJUSTABLE ADJUSTABLE 8 REB/BLUE JUMPS TO CHANGE ADJUSTABLE ADJUSTABLE 9 BLUE/GREEN JUMPS TO CHANGE ADJUSTABLE ADJUSTABLE 10 WHITE COLOR FREQUENTLY BLINKS ADJUSTABLE ADJUSTABLE 11 WHITE COLOR GLITTERS ADJUSTABLE ADJUSTABLE 12 RED COLOR FREQUENTLY BLINKS ADJUSTABLE ADJUSTABLE 13 RED COLOR GLITTERS ADJUSTABLE ADJUSTABLE 14 GREEN COLOR FREQUENTLY BLINKS ADJUSTABLE ADJUSTABLE 15 GREEN COLOR GLITTERS ADJUSTABLE ADJUSTABLE 16 BLUE COLOR FREQUENTLY BLINKS ADJUSTABLE ADJUSTABLE 17 BLUE COLOR GLITTERS ADJUSTABLE ADJUSTABLE 18 YELLOW COLOR FREQUENTLY BLINKS ADJUSTABLE ADJUSTABLE 19 YELLOW COLOR GLITTERS ADJUSTABLE ADJUSTABLE 20 CIRCULATION MODE Code Matching: Please follow the instructions below: - Confirm it is correctly connected between power supply, LED controller& LED load. - Switch the power off,then switch it on again, &press key 5 once (within 3 seconds)the moment you see the light is on. - The LED will blink twice slowly when it is completed. Code Clearing: The code can be cleared as needed.The kit(remote&controller)will stay in the original state after code clearing and can work again when code re-matching is done. Please follow the instructions below: Confirm it is correctly connected between power supply, LED controller& LED load. - Switch the power off,then switch it on again, &long press key 5(within 3 seconds)the moment you see the light is on. - The LED blinks 9 times swiftly when completed. RECEIVED 04/10/2023 36 I P a g e ASPEN BUILDING DEPARTMENT FLARE FIREPLACES OPTIONAL BLOWER KIT FOR SCREENED UNIT The Flare silent blower kit ships standard on all Double Glass units, keeping the glass cooler to the touch, but can also be added to a safety screened unit to circulate more heat from the front of the fireplace into the room. _ -_— - — • 4 • r J_ On a Flare screen unit, the blowers will be installed and delivered with an 110V Plug. The operation of the blowers is controlled with a power ON/Off to the outlet they are connected to. The customer has the option to: • Install a smart outlet to control the blowers. • Use a wall switch to start & shutdown the blowers whenever they want. An electrician will need to wire the wall switch to control the power to the fireplace fans. • Buy a remote system for the outlet. Please note that the blowers will need air intake to work. (Same requirements for double glass) For reference to the air intake specifications for your unit please see pg. 74 of Flare Install Manual. RECEIVED 04/10/2023 37 I P a g e ASPEN BUILDING DEPARTMENT FLARE FIREPLACES VENT TERMINATION Framing for vents in combustible walls and ceilings: When passing through combustible walls and ceilings,framing will depend on the type of vent installation--horizontal or vertical. Ensure that the insulation is kept clear of the vent pipe using either a wall thimble or an attic insulation shield. Follow the installation instructions supplied with the individual venting components. � 1 These instructions should be used as a guideline and do not supersede local codes in any way.Install venting according to local codes,these instructions,the current National Fuel Gas Code(ANSI-Z223.1)in the USA or the current standards of CAN/CSA- B149.1 in Canada. Approved Pipe-This appliance is approved for use with M&G DuraVent venting and ICC. DO NOT mix pipe,fittings or joining methods from different manufacturers. For detailed DuraVent chimney installation information please use the M&G DuraVent direct vent installation manual: http://www.duravent.com For detailed ICC chimney installation information please use the ICC direct vent installation manual: http://icc-chimney.com/en/exceldirect Instructions • Where a vent pipe passes through a floor or ceiling,a ceiling firestop MUST be used to retain insulation and maintain proper clearances. Use roof support brackets where needed. • Install the first section of vent pipe into the collar on top of the fireplace. • Connections between each vent system component must be tightly joined and secured. Follow the vent manufacturer's instructions for information on how to seal and secure vent and vent connections. • Horizontal runs of vent pipe must be supported to prevent any downward sags. Horizontal pipe sections should be supported at least every 4 feet.Wall Straps can be used for this purpose. • When installing the vent pipe, make sure that the vent pipe is supported by the structural/frame surrounding and not by fireplace. Follow the vent manufacturer's instruction for information on how to install,seal,and secure vent and vent connections. WARNING! DO NOT pack insulation around the vent. Insulation must be kept back from the pipe to prevent overheating. ALWAYS maintain specified clearances around venting and firestop systems. Install wall shield and ceiling firestops as specified. RECEIVED 04/10/2023 38IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES VENT AND FIREPLACE SIZE Vent Size Flare 30 4x6 Flare 45* 5x8 or 4x6 * Flare 50 5x8 Flare 60 5x8 Flare 70 5x8 Flare 80 5x8 Flare 100 5x8 *Flare-RD-45 is shipped with 5x8 vent.All other Flare 45 are shipped with the 4x6 vent. MINIMUM COMBUSTIBLE CLEARANCES FROM VENT • HORIZONTAL VENT CLEARANCES:A minimum clearance of 3 inches(76mm)to the top and 1 inch(51mm)to the sides and bottom of the vent pipe on all horizontal runs to combustibles is required. • VERTICAL VENT CLEARANCES:A minimum of 1 inch (25mm)all around the vent pipe on all vertical runs to combustibles is required except for clearances in appliance enclosures. • Horizontal vents must be level or have a 1/4-inch rise for every 1-foot of run towards the termination. • When penetrating through combustible walls and ceilings,frame a minimum of 10.5 in x 10.5 in opening and ensure that the insulation is kept clear of the vent pipe using either a wall thimble or an attic insulation shield. use the DuraVent framing cutout dimension table based on your selected part. Frame cutout table taken from the DuraVent or ICC installation manual TABLE 1 DIRECTVENT PRO FRAMING OR CUTOUT DIMENSIONS STOCK NUMBER COMPONENT DESCRIPTION SIZE 46DVA-WT Wall Thimble 10"x 10" 46DVA-WTS Wall Thimble(Small) 9"x 9' 46DVA-WTU Wall Thimble Universal 9"x 9" 46DVA-CS Ceiling Support 10-3/4"x 10-3/4' 46DVA-FS Fire Stop 9"x 9" 46DVA-WFS Wall Fire Stop 10"x 10' 46DVA-VSS Vinyl Siding Standoff 17"x 17" 46DVA-CF Counter Flashing(Assembled) 13-1/Tx 13-1/2" 46DVA-CFK Counter Flashing(4pc.Kit) 13-1/2"x 13-1/2" 46DVA-CFKS Counter Flashing(Kit Small) 10-1/Tx 10-1/2" 46DVA-VSK Vinyl Siding Standoff(4 Pc.Kit) 13-1/2"x 13-1/2" 46DVA-VSKS Vinyl Siding Standoff(Kit Small) 10-1/Tx 10-1/2' 46DVA-IS Insulation Shield 9"x 9" 58DVA-WT Wall Thimble 10-1/2"x 10-1/2" 58DVA-WTS Wall Thimble(Small) 9"x 9" 58DVA-WTU Wall Thimble Universal 9"x 9' 58DVA-CS Ceiling Support 10-3/4"x 10-3/4" 58DVA-FS Fire Stop 10-1/Tx 10-1/2' 58DVA-WFS Wall Fire Stop 10-1/2"x 10-1/2" 58DVA-VSS Vinyl Siding Standoff 19-1/2"x 19-1/2" 56DVA-VS58DVA-CFK Vinyl Siding Standoff(4 Pc.Kit) 16"x Counter Flashing(Assembled) 16"x 16" RECEIVED 58DVA-CFK Counter Flashing(4pc.Kit) 16"x 16" 58DVA-IS Insulation Shield 11"x 11' 0 4/1 0/2 0 2 3 39IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES VERTICAL TERMINATION See the table on the previous page for minimum cutout dimensions or frame openings around wall venting. Make sure clearances to combustible material are maintained based on vent part used. Note: size of vents depends upon specific fireplace and cutout sizes vary according to the DuraVent or ICC part number used. Minimum height from roof to lowest discharge opening. Horizontal Overhang y 2 FT Vertical 2 FT MIN. MIN. wall Lowest w _ Discharge Vent Opening = Termination I F T_ ' _i = H' .-. Storm Collar X � E L Flashing,\. 12 Roof Pitch is X/12 —►.--1 inch(25.4 mm)Minimum Clearance to Combustibles Concentric Vent Pipe Vertical Vent Termination Opening/Framing will 'H=minimum height from roof to lowest discharge opening of vent. depend on the part used.See table above or vent installation manual. Termination Heights for Vents Above Flat or Sloped Roofs (Ref.NFPA 54/ANSI Z223.1) Root Pitch *Feet *Meters Flat to 6/12 1.0 0.3 6/12 to 7/12 1.25 0.38 7/12 to 8/12 1.5 0.46 8/12 to 9/12 2.0 0.61 9/12 to 10/12 2.5 0.76 10/12 to 11/12 3.25 0.99 11/12 to 12/12 4.0 1.22 12/12 to 14/12 5.0 1.52 14/12 to 16/12 6.0 1.83 16/12 to 18/12 7.0 2.13 18/12 to 20/12 7.5 2.29 20/12 to 21/12 8.0 2.44 • Minimum 24" horizontal clearance to any surface (such as an exterior wall)for vertical terminations RECEIVED 04/10/2023 40 I P a g e ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES Multiple terminations A B 6 in.(minimum)up to 20 in. Sin.minimum 152 mm/508 mm 457 mm 20 in.and over 0 in.minimum _----' -''''' l ' Gas.Wood or Fuel Oil Termination Cap 1 I 1 �. B iTAl . il'bl-•-----1, ' - .... ...%„%,,%,,..,,,...............%%,...... ..,> Gas Termination .11-1111- Cap.. 000=. ■0000 0000■ ■0000 0000■ ■0000 If using decorative cap cover(s),this distance may need to be increased.Refer to the installation instructions supplied with the decorative cap cover. _- In a staggered installation with both gas and wood or fuel oil terminations,the wood or fuel oil termination cap must be higher than the gas termination cap. HORIZONTAL TERMINATION A minimum distance of 18 inches should be kept between multiple horizontal terminations. See the table on page 32 for minimum cutout dimensions or frame openings around wall venting. Make sure clearances to combustible material are maintained based on vent part used. Note:size of vents depends upon specific fireplace and cutout sizes vary per the DuraVent part number used. w RECEIVED 04/10/2023 41IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES LENT TFRMINATI( N CL.F .RANGES O -i G .. A I D } 4'2 E �y FIXED B �1 LOSED V AL L ABBLEE CLOSED if;� M \\ B -r IV J---� -1 VK } MREA WHERE VENT TERMINAL C) AIR SUPPLY INLET IS NOT PERMITTED TERMINAL In GAS METER A ^12 inches(30 cm)min. Clearances above grade,veranda,porch,deck,or balcony B **12 inches(30 cm)min. Clearance to window or door that may be opened C 12 inches(30 cm) min. Clearance to permanently closed window recommended to prevent condensation on window D 24 inches(76 cm) min.for Flare units 80" Vertical clearance to ventilated soffit located above the terminal within and 100" a horizontal distance of 2 feet(60 cm)from the edge of the terminal 18 inches(46 cm) min.for Flare units 70" and below(vinyl surfaces require 24 inches (61 cm)min.) E 24 inches(76 cm) min.for Flare units 80" Clearance to unventilated soffit. and 100" 18 inches(46 cm) min.for Flare units 70" and below(vinyl surfaces require 24 inches (61 cm)min.) F 6 inches(15 cm) min. Clearance to outside corner G 6 inches(15 cm)min. Clearance to inside corner H 3 feet(90 cm) min. *Not to be installed above a meter/regulator assembly within 3 feet(90 cm) horizontally from the centerline of the regulator I 3 feet(90 cm)min. Clearance to service regulator vent outlet J *12 inches(30 cm) min. Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance K *6 feet(1.8 m)min. Clearance to a mechanical air supply inlet L ***7 feet(2.1 m) min. Clearance above paved sidewalk or a paved driveway located on public property M ****20 inches(51 cm) min. Clearance under veranda, porch,deck,or balcony A Vent shall not terminate directly above a sidewalk or paved driveway,located between two single family dwellings,serving both dwellings. ** Only permitted if veranda,porch,deck,or balcony is fully open on a minimum of 2 sides beneath the door. * Clearance in accordance with local installation codes and the requirements of the gas supplier. * As specified in CGA B149 Installation Codes,note local Codes or Regulation may require different clearances. * For U.S.A.Installations follow the current National Fuel Gas Code,ANSI Z223.1 *** Horizontal vent termination minimum clearance to adjacent structure or fence is 48".**** Minimum 24"horizontal clearance to any surface(such as an exterior wall)for vertical terminations. RECEIVED 04/10/2023 42IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES VENT RESTRICTOR SETUP Flare Fireplace direct vent system is equipped with a vent restrictor. Use Chimney Path Installation and Planning on the next page to determine the right vent restrictor setup for your installation. Vent restrictor changes and setup should only be done by a certified installer. • The unit leaves the factory with the vent restrictor open. • The vent restrictor is adjusted using a 10mm wrench below the front upper frame. • The vent restrictor setting is from 1(minimum restriction)to 6(maximum restriction). • The installer will document the restrictor setting in the end of the installation. • Use the vent planning guide and table to determine the restrictor setting. iMilir-701/ ill 1 6 j Q Signs the vent restrictor needs to be adjusted: Vent restrictor should be opened if the flame has the following characteristics: • Flame is excessively tall and lifting. • Flame lacks movement. Vent restrictor should be closed if the flame has the following characteristics: • Flame height is low. • Flame has excessive movement Document any change to the restrictor setting. Contact Flare Fireplaces for support if needed. J RECEIVED 04/10/2023 43IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES CHIMNEY PATH INSTALLATION AND PLANNING Before vent installation,the installer should read these instructions to ensure the proper vent configuration has been selected. To calculate the vent runs, use the following tables and instructions. Please note that power vent runs are model (burner) specific. Use the tables below to calculate the restrictor setting.These fireplaces are designed and tested to function with natural venting in equal pressure environments.The natural venting allows hot air and CO2 to rise and exhaust out through the vent naturally while simultaneously creating a slight draft of oxygen to allow the flame to burn clean and efficiently. Please know that if your installation environment presents negative or positive pressure,caused by strong HVAC systems or kitchen hoods,a power vent system may be needed to counter this unique environment. General Instructions • Diagonal runs have both vertical and horizontal vent aspects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect. • Various combinations of vent runs may be used. Refer to the tables below based on Fireplace size. Use the attached example for clarification on how to use the table. • The numbers in the table represent the restrictor setting based on the vent path. • Symbol "x"in the table means the path is not allowed. • Setting the restrictor to 1 means there is no restriction. • Numbers in the table represent the restrictor setting to be set. • Document the restrictor setting configuration prior to leaving the installation site. • The tables apply to both NG (Natural Gas)and Propane. • Minimum 3 ft vertical run(A) required before any bend or turn. o See Flare Front and Flare See Through exception. o See Flare 50&60 5x8 table for exception • A maximum of four 902 vent elbows are allowed in the vent run.Any configuration with more than 4 elbows requires vent review and approval from Flare Fireplaces. • Two 452 elbows may be used in place of one 902 elbow. • The tables represent the manufacturer's guideline based on testing and design.Additional external factors may affect the restrictor choice needed. If flame appears to be not typical, please contact Flare Fireplaces for restrictor size recommendations. • Use the empty table in the page below to document and calculate the installation vent path. • Any venting pathway that does not appear the tables below require approval from Flare Fireplaces. For optimum performance and flame appearance, keep the vent length to a minimum and limit the nurrRrEpVED 04/10/2023 44IPage ASPEN BUILDING DEPARTMENT AFLARE FIREPLACES FLARE 30/30H/PASSAGE Suitable for all Flare 30 Fireplaces Length Calculation Guide G C Y-Effective Axis Parameters ji 01. �1 E e A- 1st Flue Length(3 ft. Minimum Rise) E._I—, m B - Vertical Flue Length B C- Roof Terminal = 1.5 ft. _0'ay E . H FM� 1 H - Small Elbow (45') = 1 ft. E B 'D —' X-Effective Axis Parmeters 1 'ilk H D- Horizontal Flue Length -1 E - Elbow (90') = 3 ft. F - Elbow (Lying 901 = 6 ft. I II I G - Wall Terminal = 3 ft. I I Vent Restrictor Setting:Set to 1-6 based on Table below. X: Run may need to be Power Vented Fwe30/30H X- Effective Horizonal Length FEET 0 10' I 13' I 17' I 20' I 23' I 26' I 30' I 33' I 36' I 39' -< 3' 3 2 1 i 1 1 1 1 1 1 X X X X m 6' 3 2 2 1 1 . 111 1 1 1 1 X X io' 3 2 2 1 1 1 1 1 1 1 1 1 1 CD n 13' 2 2 1 1 1 1 1 1 1 1 1 1 1 <' 16' 2 1 1 1 1 1 1 1 1 1 1 1 1 19' 2 1 1 1 1 1 1 1 1 1 1 1 1 CD 23' 2 1 1 1 1 1 1 1 1 1 1 X X t' F—i- 26' 1 1 1 1 1 1 1 1 1 1 1 X X n.CO 3°' 1 1 1 1 1 1 1 1 1 X X X X 33' 1 1 1 1 1 1 1 1 1 X X X X 36' 1 1 1 1 1 1 X X X X X X X MI 39' 1 1 1 1 1 1 X X X X X X X = 43' 1 1 1 1 1 1 X X X X X X X 46' 1 1 1 1 1 1 X X X X X X X so' 1 1 1 1 1 1 X X X X lk,E CtIVED 04/10/2023 45IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES FLARE 45/45H/45EH Suitable for all Flare 45/45H/45EH Fireplaces Length Calculation Guide G C '' Y-Effective Axis Parameters • B 1 E l— A - 1st Flue Length (3 ft. Minimum Rise) E,.-4 E -, B - Vertical Flue Length B E , H C- Roof Terminal = 1.5 ft. O''' . F f� 1 H Small Elbow (45") = 1 ft. ��r B X-Effective Axis Parmeters Ali& H D- Horizontal Flue Length �' E - Elbow (90') = 3 ft. r� F - Elbow (Lying 901 = 6 ft. 1 II !II I G - Wall Terminal = 3 ft. I I Vent Restrictor Setting:Set to 1-6 based on Table below. X:Run may need to be Power Vented Flare 45/45H/45EH X- Effective Horizonal Length 1 FEET 6' I 10' I 13' I 17' I 20' I 23' I 26' I 30' I 33' I 36' I 39' 3' 1 1 1 1 1 1 1 1 X X X X X rn 6' 3 2 2 1 1 1 1 1 X X X X X � 10' 3 2 2 1 1 1 1 1 1 1 X X X CD r) 13' 2 2 2 1 1 1 1 1 1 1 1 1 X r-i- <' 16' 2 1 1 1 1 1 1 1 1 1 1 1 X 19' 2 1 1 1 1 1 1 1 1 1 1 X X CDC 23' 1 1 1 1 1 1 1 1 1 1 X X X r�-h 26' 1 1 1 1 1 1 1 1 1 X X X X .� 30' 1 1 1 1 1 1 1 1 X X X 33' 1 1 1 1 1 1 1 1 X X X X X r CD 36' 1 1 1 1 1 1 1 1 X X X X X D 01:1 39' 1 1 1 1 1 ' 1 1 X X X X X X S 43' 1 1 1 1 1 1 1 X X X X X X 46' 1 1 1 1 1 1 X X X X X X X 50' 1 1 1 1 1 1 X X X X X ECXEIvXE 04/10/2023 46IPage ASPEN BUILDING DEPARTMENT AFLARE FIREPLACES FLARE 50/50H/50EH Suitable for all Flare 50/50H/50EH Fireplaces Length Calculation Guide C G I Y-Effective Axis Parameters ell E A-1st Flue Length(3 ft.Minimum Rise) E, � E D D i B-Vertical Flue Length B H E C-Roof Terminal=1.5 ft. ,.O"‘I • I H-Small Elbow(45°)=1 ft. F _fmmummar E X-Effective Axis Parmeters A _° �• H D-Horizontal Flue Length A I E-Elbow(90°)=3 ft. F-Elbow(Lying 90°)=6 ft. l II !il I I I G-Wall Terminal=3 ft. Vent Restrictor Setting:Set to 1-6 based on Table below. X: Run may need to be Power Vented Flare 50/50H X- Effective Horizonal Length FEET 0 1 10' , la' I 20' 23 26 I 30' I 33' 1 36' 3' 2 2 2 2 1 1 1 1 1 1 1 X X 1 rn 6' 3 3 2 2 2 2 1 1 1 1 1 1 1 fD 10' 3 3 2 2 2 2 1 1 1 1 1 1 1 n 13' 3 3 2 2 2 1 1 1 1 1 1 1 1 C 16' 3 3 2 2 2 1 1 1 1 1 1 1 1 19' 2 2 2 2 2 1 1 1 1 1 1 1 1 C 23' 2 2 2 2 1 1 1 1 1 1 1 1 1 r•-r 26' 2 2 2 2 1 1 1 1 1 1 1 1 1 v 3°' 2 2 2 1 1 1 1 1 1 1 1 1 1 33' 1 1 1 1 1 1 1 1 1 1 1 1 1 I— fD 36' 1 1 1 1 1 1 1 1 1 1 X X X D 0'I 39' 1 1 1 1 1 1 1 1 1 1 X X X rrt — = 43' 1 1 1 1 1 1 1 1 1 1 X X r X 46' 1 1 1 1 1 1 1 1 1 X X X X so' 1 1 1 1 1 1 1 I 1 1 X X X X RECEIVED 04/10/2023 47 I f ASPEN BUILDING DEPARTMENT AFLARE FIREPLACES FLARE60/6OH/6OEH Suitable for all Flare 6O/6OH/6OEH Fireplaces Length Calculation Guide `p G i C Y-Effective Axis Parameters • B I E A- 1st Flue Length(3 ft. Minimum Rise) All Ili Er ea ' B-Vertical Flue Length B E H C- Roof Terminal=1.5 ft. �-`' • F ��H -Small Elbow(45") = 1 ft. r B D�2 X-Effective Axis Parmeters A N. D-Horizontal Flue Length A I E- Elbow(901 =3 ft. F- Elbow(Lying 90°) =6 ft. I II !Il I G-Wall Terminal = 3 ft. I I Vent Restrictor Setting:Set to 1-6 based on Table below. X: Run will need to be Power Vented Fare 60/60H X- Effective Horizonal Length FEET I 6' I 10' I 13' I 17' r 20' I 23' T 26' I 30' I 33' I 36' I 39' 3' 1 2 2 1 1 1 1 1 1 1 1 X X X m 6' 3 3 2 1 1 1 1 1 1 1 1 1 X fD so' 2 2 2 1 1 1 1 1 1 1 1 1 1 r�-F 13' 2 2 2 2 1 1 1 1 1 1 1 1 1 < 16' 2 2 2 1 1 1 1 1 1 1 1 1 1 CD 19' 2 2 1 1 1 1 1 1 1 1 1 1 1 rD 23' 2 2 1 1 1 1 1 1 1 1 1 1 1 -' rfi 26' 1 1 1 1 1 1 1 1 1 1 1 1 1 n, 30' 1 1 1 1 1 1 1 1 1 1 1 1 1 I— 33' 1 1 1 l 1 1 1 1 1 1 1 X X X CD 36' 1 1 1 1 1 1 1 1 1 1 X X X O't) 39' 1 1 1 1 1 1 1 1 1 1 X X X : 43' 1 1 1 1 1 1 1 1 1 X X X X 46' 1 1 1 1 1 1 1 1 1 X X X X 5°' 1 1 1 1 1 1 1 1 1 X X X X RECEIVED 04/10/2023 48IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES FLARE 70/70H/70EH Suitable for all Flare 70/70H/70EH Fireplaces Length Calculation Guide O' G V c Y-Effective Axis Parameters de s I E III m A- 1st Flue Length (3 ft. Minimum Rise) E .- 1- D —,1111 B -Vertical Flue Length B i E H C- Roof Terminal = 1.5 ft. O' if F dI . 1 H-Small Elbow (45") = 1 ft. E B D 11111 X-Effective Axis Parmeters A I ' H D- Horizontal Flue Length �' E- Elbow (901 = 3 ft. F - Elbow (Lying 90') = 6 ft. l II !Il I G -Wall Terminal = 3 ft. I I Vent Restrictor Setting:Set to 1-6 based on Table below. X: Run will need to be Power Vented 11Oore 70/70H/70EH X- Effective Horizonal Length FEET 0 3 I 6' I 10' I 13' I 17' I 20' I 23' I 26' I 30' I 33' I 36' I 39' 3' 1 1 1 1 1 1 1 1 1 X X X X 6' 2 2 1 1 1 1 1 1 1 1 X X X 1.:7111"1 10' 321111111111X CD 13' 321111111111X 16 2211111111111 19' 221111111111X 23 21111111111XX 26' 1 1 1 1 1 1 1 1 1 1 X X X n 30' 1 1 1 1 1 1 1 1 1 1 X X X IU 33' 1 1 1 1 1 1 1 1 X X X X X (D 36' 1 1 1 1 1 1 1 1 X X X X X D 0r4 39' 1 1 1 1 1 1 1 X X X X X X r--t S 43' 1 1 1 1 1 1 1 X X X X X X 4 6' 1 1 1 1 1 1 1 X X X X X X 50' 1 1 1 1 1 1 1 X X X X X X RECEIVED 04/10/2023 49IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES FLARE 80/80H/80EH Suitable for all Flare 80/80H/80EH Fireplaces Length Calculation Guide 'cp G c Y-Effective Axis Parameters •� B I E B A- 1st Flue Length (6ft.Minimum Rise) e,.-111-+ e m B -Vertical Flue Length B C- Roof Terminal = 1.5 ft. r0"' E � H F f� � H-Small Elbow (45") = 1ft. .E B 11.111141( X-Effective Axis Parmeters `� A I . H D- Horizontal Flue Length A' E- Elbow (90") = 3 ft. F - Elbow (Lying 90') = 6 ft. l II I G - Wall Terminal = 3 ft. I I Vent Restrictor Setting:Set to 1-6 based on Table below. X: Run will need to be Power Vented Fiore 80/80H/80EH X- Effective Horizonal Length FEET 0 I 3 I 6' I 10' I 13' I 17' I 20' I 23' 1 26' I 30' I 33' I 36' I 39' 3' X X X X X X X X X X X X X rn 6' 2 1 1 1 1 1 X X X X X X X fi 10' 2 2 1 1 1 1 1 1 X X X X X (D f) 13' 2 2 1 1 1 1 1 1 1 X X X X rt <' 16' 2 1 1 1 1 1 1 1 1 X X X X 19' 2 1 1 1 1 1 1 1 1 X X X X f 23' 1 1 1 1 1 1 1 1 1 1 X X X e�-F 26' 1 1 1 1 1 1 1 1 1 1 1 X X n•EU 30' 1 1 1 1 1 1 1 1 1 1 X X X r 33' 1 1 1 1 1 1 1 1 1 X X X X fD 36' 1 1 1 1 1 1 1 1 X X X X X D 0r4 39' 1 1 1 1 1 1 1 1 X X X X X r-P S 43' 1 1 1 1 1 1 1 X X X X X X 46' 1 1 1 1 1 1 X X X X X X X so' 1 1 1 1 1 1 X X X X X X X RECEIVED 04/10/2023 50IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES FLARE 100/100H/100EH Suitable for all Flare 100/100H/100EH Fireplaces Length Calculation Guide G c Y-Effective Axis Parameters � B I E { E A- 1st Flue Length (6ft.Minimum Rise) E l-, m B -Vertical Flue Length B 1 C- Roof Terminal = 1.5 ft. .�' ' E F \ H-Small Elbow (45`) = 1 ft. f� E B D 1, X-Effective Axis Parmeters D Horizontal Flue Length f I E- Elbow (90") =3 ft. r� F - Elbow (Lying 901 = 6 ft. I II I G - Wall Terminal =3 ft. I I Vent Restrictor Setting:Set to 1-6 based on Table below. X: Run will need to be Power Vented X- Effective Horizonal Length 100/100N/IOOEHFEET0 3 6' I 10' 13' 17' I 20' I 23' I 26' I 30' I 33' I 36' 39' 3' XXXXXXXXXXXXX 1111Flare 6' 211111XXXXXXX io' 22111111XXXXX 13' 221111111XXXX 16' 211111111XXXX 19' 211111111XXXX z3' 1111111111XXX (121 CD z6' 11111111111XX 30' 1111111111XXX 33' 1 1 1 1 1 1 1 1 1 X X X X 36' 1 1 1 1 1 1 1 1 X X X X X D 39' 1 1 1 1 1 1 1 1 X X X X X lir* 43' 1 1 1 1 1 1 1 X X X X X X 46 1 1 1 1 1 1 X X X X X X X so' 1 1 1 1 1 1 X X X X X X X RECEIVED 04/10/2023 511Page ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES For unsupported vent routes(based on the gravity vent tables above)a power venting solution is required.The power venting solutions allow Flare Fireplaces to operate in vent conditions that would not be possible without the motor unit.See the Flare Power Vent Installation Manual for more specific instructions. The system is designed and tested with DuraVent 3x5 gasket direct vent pipes. It is critical for the safety and operation of the system to use the DuraVent 3x5 gasket system. Front view Side view [12 313.40 . fir _ — . r , . i Air Intoke� I Q o \ I �� i tI i.10 Smoke C �, `� 439 Top view Side view 1 3/5,. [12A"1 11 . 312 19 16' 500 lkoc ke op?000l I J • IIli' 424 I �' pep N' — - Power Cable �; Control COON `� kockN opiofd 2 INLET OPTION 2 Open hoot Moos*must not be bRt CE IVE D 04/10/2023 52IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES When using the power vent system,direction of flow through the vents can be up,down, horizontal or diagonal since the system is sealed and vacuumed.The vent restrictor level should be set based on length in feet, number of elbows and the vent termination. NOTE:A minimum length of 12ft venting is required between the Fireplace and the SK, Flare Fireplaces sizes 30"-70".A minimum length of 15ft, Flare sizes 80"-100", is required between the fireplace and the SK. For more information, please reference the Power Vent Installation Manual. Clearance-Clearances between the vent pipe and combustible materials must be maintained at 3" inches top and 1"for side and below. Maintain the same clearance from the power vent box to any combustible materials. Vertical Wall PV INLINE Now • • . .. .. .. .. .. . . . • . . . . • • . . . . . . • • . . t l 1. • . t. .t 8 • • I I Power vent unit must be installed by a qualified installer in accordance with these instructions. CAUTION! Failure to install,operate,and maintain the power venting system in accordance with manufacturer's instructions will result in conditions which may produce bodily injury and/or property damage J RECEIVED 04/10/2023 53IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES ELECTRICAL CONNECTION TO THE PV SYSTEM • The PV system will need to be connected to an AC 110V 15A power outlet. • The PV system is connected to the Fireplace control system with a low voltage(6V)3 wire cable-labeled below as connection "Fan Exhust Optional". • Cable to be used is 16 AWG-3 copper wire(not solid wire). Cable is not included with the PV kit. • Connect low voltage cable from the Power Vent to Connection 6(below), matching colors-white to white, black to black &green to green). • fans and sensors on the main board are optional and will be included on double glass systems. • b� • Bypass , LA r BV OUT Fan Exhust 1 (optional) J- Ill PV Control Board GNO - + GNO - + 1 w O Q Q 110V AC 0 D U cool Fan 1 G 44 43 42 41 40 39 110V AC Input o A + C 49 48 47 X 46 45 011 DC 6V 000 White Black Green rywSenu / Blue LED-PV/FE Red LED-Power To Fireplace Board White LED- Relay 6V DC—3 line wire Master Bypass Main Board 2019 • PV/F.E 6V Relay DG Fans Optional LED 110V Summer Kit Plug Plug Plug Plug plug 110VACInput " N 1213io 9 11111111 oswz o„ Blue LED-PV/FE Red LED-Power 8 7 6 5 4 3 2 1 oswl • • 11111111 White LED-Relay R ■ CEIVED Fan LED Indicators Q 12 11 10 9 8 7 6 5 4 3 2 1 1 4/10/2023 54IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES GAS INSTALL GENERAL 111VARNING! Risk of Fire or Exp osiom All gas handling and installation should be performed by qualified service technician or installer. Gas build-up during line purge could ignite. Ensure adequate ventilation. Make sure there are no ignition sources/sparks or open flames. Do not change the gas valve setting! The fireplace gas valve has been preset at the factory. Installing an external manual gas valve before connection to the fireplace is a must. Make sure to check for gas leaks before lighting the fireplace for the first time. When checking for leaks do not use open flame. / 1 This appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at test pressures more than% psig(3.5 kPa). This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig(3.5 kPa). • Move the appliance into position and secure it to the wall using the back or side mount. • Install a manual gas valve before the connection to the fireplace appliance automatic valve. • Connect the gas line to the fireplace.The appliance is designed to accept a 1/2"(13mm)gas supply. • Connect the gas supply in accordance with local codes,CAN/CSA-B149.1 in Canada or to the current National Fuel Gas Code,ANSI Z223.1/NFPA 54 in the United States. • Check for gas leaks using non-corrosive commercially available leak-check solution before operating the gas appliance. • Measure and document gas pressure here: Inlet W.C. Burner(Manifold) W.C. --Make sure the Min/Max inlet pressure match the table below. • Lighting the fireplace for the first time may take some time until the line is purged. Note: Do not place the gas valve or controls above the level of the burner. Gas Pressure Natural Gas Propane Inlet pressure 7.0" W.0 10". W.0 Acceptable Inlet Gas pressure table WARNING! Risk of Fire or Explosion! High pressure will damage valve. Low pressure could cause explosion. Verify inlet pressures. Verify minimum pressures when other household gas appliances are operating. RECEIVED 04/10/2023 55IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES Stepper motor Main saltie connection(ereen) to Outlet pressure tap —�' Pilot connection(orange) i / - -` 40v_ e 1 l • • e 4 ` Inlet pressure tap Pilot flame adjustment miiii410 44. r 4 `mi. 4 , � - +AIli I' lit - , 0 • Have the gas supply line installed in accordance with local codes, if any. If not available,follow ANSI 223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality(in the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter). RECEIVED 04/10/2023 56 I P a g e ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES USING A REDUCER TO DE-RATE YOUR FLARE FIREPLA_ I Flare Fireplaces appliances use the SIT ProFlame II valve and are tested/approved for installations at elevations of 0-4500 feet(0- 1372 meters) above sea level using the standard burner orifice sizes.At the time of installation, it must be determined by the installer if the appliance needs to be de-rated for elevations above 4500 feet. Contact your local gas supplier for the de-ration requirements in your area. Only use the Flare Fireplaces de-rating reducer on installations above 4500 Ft. If the installer must convert the unit to adjust for varying altitudes, the information sticker must be filled out by the installer and adhered to the appliance at the time of conversion. DE-RATE TABLE MODEL GAS TYPE REDUCER SIZE CALC BTU. STANDARD BTU 30" LPG 1.6 mm 18000 23000 45" LPG 1.9 mm 22000 28000 50" LPG 2.0 mm 27000 35000 60" LPG 2.2 mm 36000 43000 70" LPG 2.5 mm 38000 45000 80" LPG 2.7 mm 42000 49000 100" LPG 2.9 mm 51000 57000 30" • 3.0 mm 27000 33000 45" NG 3.2 mm 30000 36000 50" NG 3.5 mm 35000 45000 60" .__ 3.8 mm 40000 51000 70" NG 4.1 mm 44000 52000 80" NG 4.5 mm 48000 55000 100" NG 4.7 mm 49000 57000 RECEIVED 04/10/2023 57IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES ADDING THE FLARE FIREPLACES DE-RATING REDUCER Add the de-rating reducer when your fireplace is being installed at elevations over 4500 ft above sea level. Please contact your local gas supplier for de-ration requirements in your area. 1. Shut off gas, remove power, and locateft co - your gas valve. Once disconnected, verify direction of gas flow by locating the flow- rn arrow on top of the valve. Turn off gas and o remove hard line to valve. SEE EXAMPLE 1 .0 fl�.r, 41- 41Pli /.1 - HISHI r.-e7, it!) ! ice* . * qt. _ mph v , - EXAMPLE 1 2. Add reducer between gas hard line and T' • flex line connected to SIT ProFlame valve ° =;� on the burner side. Us appropriate reducer , ' as specified in "DE-RATE TABLE". o SEE EXAMPLE 2 411 �i, :. F"u o- BURNER SIDE EXAMPLE 2 11 RECEIVED 04/10/2023 58 I P a g e ASPEN BUILDING DEPARTMENT FLARE FIREPLACES ORIFICE SIZE Flare Fireplace appliances are tested and approved for installations at elevations of 0-4500 feet(0-1372 meters)above sea level using the standard burner orifice sizes.At the time of installation, it must be determined if the appliance needs to be de- rated. Contact your local gas supplier for deration requirements for your area. De-rated installation consideration can start at 2000 Ft above sea level.At higher elevations,the amount of BTU fuel value delivered must be reduced by either using gas that has been de-rated by the gas company or by changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the(USA) National Fuel Gas Code NFPA 54/ANSI Z223.1- latest edition or in Canada,the CAN/CSA- B149.1 code—latest edition. GAS VALVE ACCESS DOOR The Flare Fireplace gas valve and control system is on an "umbilical cord"that can be stretched up to 50"from the middle of the fireplace and be put next to the access door location. Do not place the gas valve or controls above the level of the burner. If the fireplace is to sit low on the floor,the controls must be placed outside the non-combustible zone or insulated from the heat from the fireplace.The access door can be placed on any side of the fireplace, below the non-combustible line.The use of a 10"x10"access door is highly recommended. If no access door is installed, it is possible to access the gas valve from inside the fireplace by removing the glass.The access door can also be used as a lower air intake for a double glass installation if it is perforated, and the opening requirements are maintained.The access door can be concealed in many ways such as HVAC vent cover, removable tile connected with Velcro straps and more. MANUAL GAS SHUTOFF The installation of this appliance REQUIRES the implementation of a readily accessible Manual Gas Shut Off. Confirm requirements of location and shut off type with your local codes. NOTE:The Electronic Ignition of Flare Fireplaces DOES NOT satisfy the requirement for a Manual Gas Shut Off. See below for example of Manual Gas Shut Off Bowl, RECEIVED 04/10/2023 59IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES LIQUID PROPANE USAGE IN FLARE FIREPLACES The Flare Fireplace can operate and fire using Natural Gas (Default) or Liquid Propane gas. If your installation requires the fireplace to operate using Liquid Propane gas, make sure only to use the Flare Fireplaces liquid propane conversion kit. Depending on your fireplace ignition system, LPG conversion kit may include the following: • LPG burner orifices • Pilot LPG orifices • SIT Valve LPG Conversion Kit NEVER OPERATE A FIREPLACE ORDERED FOR NATURAL GAS WITH LP GAS UNLESS CONVERTED BY A CERTIFIED FIREPLACE TECHNICIAN. USE ONLY FLARE FIREPLACE LP CONVERSION KIT. ALWAYS MEASURE GAS INLET PRESSURE AND OUTLET PRESSURE POST CONVERSION Your Fireplace may be shipped to support Liquid Propane Gas. Check your Flare Fireplaces gas rating plate at the back of your valve to confirm the gas type. Use the following link for the Flare Fireplace NG to LPG conversion on SIT ignition Use the following link for the Flare Fireplace NG to LP conversion on Maxitrol ignition NOTICE Flare Fireplaces does offer the ability to run your fireplace with a liquid propane tank though there are certain limitations this fuel type presents when compared to the usage of natural gas. Liquid propane burns more efficiently and hotter than natural gas so to accommodate this increase in heat we must use smaller orifices to achieve a lower BTU that can cause your flame to appear smaller than on a unit run on natural gas. Flame height on Flare Fireplaces using Liquid Propane is roughly 4-6" in height because of this adjustment. RECEIVED 04/10/2023 6OlPage ASPEN BUILDING DEPARTMENT FLARE 1/41/4,S FIREPLACES COMMONWEALTH OF MASSACHUSETTS State of Massachusetts Carbon Monoxide Detector/Vent Terminal Signage Requirements for all side wall horizontally vented gas fueled equipment installed in every dwelling,building or structure used in whole or in part for residential purposes,including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven(7)feet above finished grade around the venting,including but not limited to decks and porches,the following requirements shall be satisfied: 1. INSTALLATION OF CARBON MONOXIDE DETECTORS.At the time of installation of the side wall horizontal vented gas fueled equipment,the installing plumber or gas fitter shall observe that a hard-wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed.In addition,the installing plumber or gas fitter shall observe that a battery operated or hard-wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling,building or structure served by the side wall horizontal vented gas fueled equipment.It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard-wired carbon monoxide detectors. a. If the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic,the hard-wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. b. If the requirements of this subdivision cannot be met at the time of completion of installation,the owner shall have a period of thirty(30)days to comply with the above requirements;provided,however,that during said thirty(30)day period,a battery-operated carbon monoxide detector with an alarm shall be installed. 2. APPROVED CARBON MONOXIDE DETECTORS.Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certified. 3. SIGNAGE.A metal or plastic identification cation plate shall be permanently mounted to the exterior of the building at a minimum height of eight(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment.The sign shall read,in print size no less than one-half(1/2)inch in size,"GAS VENT DIRECTLY BELOW.KEEP CLEAR OF ALL OBSTRUCTIONS". 4. INSPECTION.The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless,upon inspection,the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2)(a)1 through 4. (b)EXEMPTIONS.The following equipment is exempt from 248 CMR 5.089(2)(a)1 through 4. 1.The equipment listed in Chapter 10 entitled"Equipment Not Required to Be Vented"in the most current edition of NFPA 54 as adopted by the Board;and 2.Product Approved side wall horizontal vented gas fueled equipment installed in a room or structure separate from the dwelling,building or structure used in whole or in part for residential purposes. (c)MANUFACTURER REQUIREMENTS—GAS EQUIPMENT VENTING SYSTEM PROVIDED.When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment,the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 1.Detailed instructions for the installation of the venting system design or the venting system components;and 2.A complete parts list for the venting system design or venting system. (d)MANUFACTURER REQUIREMENTS—GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED.When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fuel gases,but identifies"special venting systems",the following requirements shall be satisfied by the manufacturer. 1.The referenced"special venting system"instructions shall be included with the appliance or equipment installation instructions;and 2.The"special venting systems"shall be Product Approved by the Board,and the instructions for that system shall include a parts list and detailed installation instructions. (e))A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment,all venting instructions,all parts list for venting instructions,and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. RECEIVED 04/10/2023 61IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES FLARE FIREPLACES - DOUBLE GLASS OVERVIEW With an effort to make our fireplaces safer, Flare Fireplaces is offering our full line of products with safety double glass technology.The Flare Fireplace double glass is built with two layers of glass.The design allows cool air to flow between the two layers,with the help of built-in blowers,which significantly lowers the temperature of the external glass, making it safe for a brief touch. Double Glass is suitable for commercial as well as residential use. The double glass feature provides a sleek look with no frame,while maintaining heating characteristics and efficiency.This feature does not affect the clearance or venting requirements. Heat Release - Cooled External Glass — 3 ■ ;r Active Blowers Air Intake RECEIVED 04/10/2023 62 I P a g e ASPEN BUILDING DEPARTMENT FLARE FIREPLACES DOUBLE GLASS - INSTRUCTIONS The double glass design depends on the blower's ability to move room temperature air from the lower air intake, up between the internal and external glass,through the chase above the fireplace, and out the upper heat release.These relatively quiet blowers cannot be turned off and are required for the continued operation of your Double Glass system. The following sizes MUST be maintained for the upper heat release: For fireplaces sized 80"& 100"—vent area must be at least 200 square inches OPEN AIR FLOW. For fireplaces sized 60"&70"-vent area must be at least 140 square inches OPEN AIR FLOW. For fireplace sized 50"and below-vent area must be at least 100 square inches OPEN AIR FLOW. The following sizes MUST be maintained for the lower air intake: For fireplaces sized 80"& 100"—vent area must be at least 100 square inches OPEN AIR FLOW. For fireplaces sized 60"&70"-vent area must be at least 70 square inches OPEN AIR FLOW. For fireplaces sized 50"and below-vent area must be at least 50 square inches OPEN AIR FLOW. FOR SEE THROUGH FIREPLACES THE AIR INTAKE REQUIREMENTS ARE DOUBLE, EQUAL ON BOTH SIDES. NOTE:Openings above for Heat Release and Air Intake are measured for open air space. NOTE:On all See Through and Room Definer units the air intake must be doubled To reduce you chase and double glass heat increase your heat release&air intake above listed minimum. The upper heat release may be a single or multiple opening if the total size of all the openings is at least the minimum requirement listed above.They can be set at the front, back, sides or top. The lower air intake may be a single or multiple opening if the total size of all the openings is at least the minimum requirement listed above.They can be set at the front, back, or sides. It is recommended to place one long opening on below the long glass,to allow for better distribution across all fans of air taken in from the bottom. If implementing side air intakes, make sure side opening are not farther than 2 feet to the side of the fireplace. On all See Through and Room Definer units the air intake must be double,to accommodate fans on either facing. Lower air intake is REQUIRED for Double Glass and units with an optional blower kit. RECEIVED 04/10/2023 63IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES MIQUIREMENT — ELECTRICAL RtIREMENT Screen Unit: 110V, 15A Outlet (Dedicated circuit is optional but recommended) or directly wired. When using an outlet, make sure the outlet is accessible in the event of servicing. **110V, 15A additional power source needed if Optional RGB-LEDs are included in unit. Double Glass: 110V, 15A Outlet (Dedicated circuit is optional but recommended) or directly wired. When using an outlet, make sure the outlet is accessible in the event of servicing. **No additional power source needed for optional RGB-LEDs. ELEVISION MOUNTING ABOVE FIREPLACE The Flare Fireplace frameless design directs the heat from the fireplace into the fireplace chase to be released from the top vent opening. The design allows for a relatively low temperature on the external wall above the fireplace. Follow the charts and instruction below for suggested installation of a television above the fireplace. • Please note that electric wiring used for the television must be insulated when installed inside the chase above the fireplace. • It is critical that wiring insulation does not obstruct the hot air flow from going to the top part of the chase to be released back to the room. • Placing insulation above the fireplace may result in a Fire hazard. Air flow above the fireplace should remain open to allow heat to be released from the top of the chase. • Follow the chart below for clearance and sizing. • It is recommended to double wall the area behind the TV to allow cables and other related material to be installed with less concern of blocking hot air flow. Use non-combustible material for double wall. • All wires MUST be secured and anchored to the frame to prevent any possibility of wires dropping on top of the Fireplace. • TV can be recessed when installed above the Fireplace, be protected by a mantel or flush installed above the fireplace. • Wires should be inserted into the recess from the top or sides (In order to avoid proximity to the fireplace vent). • To reduce the amount of heat around and below the TV, increase the size of the heat release above the minimum required for your fireplace size unit. *Please note that most television manufactures and manuals will instruct the owner not to install television above or near a fireplace. Mounting a television above the fireplace is based on the owner's decision and responsibility. Flare will not be held liable for any adverse effects on a TV, artwork or other equipment located near the Flare appliance. It is the customer's responsibility to verify that their TV or artwork can withstand the wall temperatures at the installation site. RECEIVED 04/10/2023 641Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES TV INSTALL — FLAT EXAMPLE • Combustible Material 11 Non-Combustible Material I Maintain 1"Min. clearance to vertical vent pipe Maintain3" Min. 12" Min clearance to combustible frame Maintain 2" Min. minimum clearance to non-combustible cover C • • i •• • • *THE EXAMPLE SHOWN ABOVE IS NOT AN EXACT RENDERING OF EVERY FIREPLACE STYLE AND VENT PLACEMENT OFFERED BY FLARE BUT MEANT TO CONVEY RELEVANT MEASUREMENTS FOR USE ON ALL UNIT INSTALLATIONS. FOR EXACT DRAWINGS OF THE FIREPLACES AND THEIR VENT PLACEMENT PLEASE DOWNLOAD DIMENSION OR FRAMING GUIDES FROM OUR DIRECT VENT DOWNLOAD CENTER WARNING — Maintain Open Air flow between the fireplace and drywall. Make sure cables or;a oI �1j�(� materials are not blocking hot air flow. �� �� �/ 04/10/2023 65IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES TV INSTALL — L TYPE E , , / , i , , , , 1T , , T i i 1 I 1 I ® I i 1 / 1ST METAL STUD ^ 6"MAX RECESS OVER FIREPLACE FLAT-FACED TO i • ALLOW AIRFLOW / T` . ice' 1"MINIMUM FROM PIPE TO NON-COMBUSTIBLE C 14"MAX TV RECESS © 12" BACK WALL MINIMUM </ 0"-4.5"RECOMMENDED MAX NON-COMBUSTIBLE 3"MINIMUM TO OVERERHANG I 8"MAX COVERED WOOD FRAMING COMBUSTIBLE MATERIAL 2"MINIMUM TO ■ NON-COMBUSTIBLE MATERIAL NON-COMBUSTIBLE 1 C ) BACK WALL • 18"NON-COMBUSTIBLE METAL FRAMING ONLY ZONE • • • • •• A. Directly over the fireplace the television recess should be no deeper than 6" inches. B. A minimum of 12" above the top of the fireplace glass opening to the underside of the recess. c. Extending the overhang to the max of 8" and recessing into the cavity to the max of 6" can create an overhang up to 14" deep. NOTE: Use non-combustible framing and finishing materials only for overhang construction, making sure your finishing materials do not extend into the glass installation zone. See an example of this above. Do not recess any deeper than 14" from the face of your finishing material to the back of the recess, as it will hinder air flow&damage the TV. *THE EXAMPLE SHOWN ABOVE IS NOT AN EXACT RENDERING OF EVERY FIREPLACE STYLE AND VENT PLACEMENT OFFERED BY FLARE BUT MEANT TO CONVEY RELEVANT MEASUREMENTS FOR USE ON ALL UNIT INSTALLATIONS. FOR EXACT DRAWINGS OF THE FIREPLACES AND THEIR VENT PLACEMENT PLEASE DOWNLOAD DIMENSION OR FRAMING GUIDES FROM OUR DIRECT VENT DOWNLOAD CENTER WARNING — Maintain Open Air flow between the fireplace and drywall. Make sure cables or aR t1j ElvED materials are not blocking hot air flow. 04/10/2023 66IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES TV INSTALL RECESS — 45 DEGREE ELBOW ON TOP OF THE UNIT When planning a TV recess, clearance to the vent pipe in the chase is critical and needs to be a minimum of 1" to the non-combustible recessed wall.This is to prevent heat from radiating from the vent to the recessed wall and being transferred to the TV. Due to the central location and diameter of the vent (8 inches) on our front facing& see-through models, one of the following solutions may be necessary to maintain the clearance requirement: 1. The television recess should be no more than 6" inches deep, 12" above the top of the fireplace glass opening. You must maintain a 1" clearance from your recess to the vent pipe to prevent overheating. 2. Install two 45 elbows directly above the fireplace followed by a minimum 4 ft vertical vent rise.The two small elbows will move the vertical section back 5 5/8". Note that the 1-inch clearance from the vent applies also to the back non-combustible wall. 3. Do not use any elbow with an angle larger than 45 degrees. 4. A 4 ft minimum vertical vent rise must be used after the two 45-degree elbows on fireplaces sized between 30" and 70". A 6 ft minimum rise will be required for units sized at 80" and 100". 5. Note: Max recess of TV into the cavity should not exceed 6". Recesses exceeding this dimension run the risk of creating a shelf and hindering air flow above unit, resulting in a wall that may overheat. 6. The following vent path should be used for Flare Front and Flare See Through only. 4x6 5x8 Offset Rise Offset Rise 5" 13 1/2" 5 5/8" 15 3/8" — I J `1 Clearance to vent increased r► . �' due t 45 degree elbow RISE Two 45 Degree elbow 4 4 Ft minimum vertical OFFSET Flare Front Vent Adapter Centered RECEIVED 04/10/2023 67IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES TV INSTALL WITHOUT RECESS — MANTEL INSTALLATION Minimum Requirements for Installing a Television without a Recess: • The TV must be at least 11 Inches total above the glass of the fireplace. • A mantel at least 1 inch thick and 6 inches deep should be installed a minimum of 8 inches above the glass. • The TV must be at least 2 inches above the mantel and 1 inch back from the edge of the mantel. • To reduce the amount of heat around and below the TV, increase the size of the heat release above the minimum required for your unit. •All measurements shown are minimum requirements. ■ Combustible • Non-Combustible 1"Min. 1"Min. 2"Min 1"Min r 8"Min IE • • *Please note that most television manufactures and manuals will instruct the owner not to install television above or near a fireplace. Mounting a television above the fireplace is based on the owner's decision and responsibility. Flare will not be held liable for any adverse effects on a TV, artwork or other equipment located near the Flare appliance. It is the customer's or contractor responsibility to verify that their TV or artwork can withstand the wall temperatures at the installation site. *THE EXAMPLE SHOWN ABOVE IS NOT AN EXACT RENDERING OF EVERY FIREPLACE STYLE AND VENT PLACEMENT OFFERED BY FLARE BUT MEANT TO CONVEY RELEVANT MEASUREMENTS FOR USE ON ALL UNIT INSTALLATIONS. FOR EXACT DRAWINGS OF THE FIREPLACES AND THEIR VENT PLACEMENT PLEASE DOWNLOAD DIMENSION OR FRAMING GUIDES FROM OUR DIRECT VENT DOWNLOAD CENTER RECEIVED 04/10/2023 68IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES CLEARANCES METAL FRAMING SPECIFICATIONS NON-COMBUSTIBLE FIRESTOP REQUIRED HEAT RELEASE 40" MINIMUM FROM TOP OF THE UNIT WITHIN 1-3" OF FIRESTOP SIZED BASED ON SIZE OF UNIT pagamisimmingimiLimmigimm I I 18" ABOVE FIREPLACE NON-COMBUSTIBLE ZONE STEEL STUDS ONLY FIRST, FLAT-FACED, METAL HEADER 1/2"MIN. IP CLEARANCE ABOVE UNIT a � 2" MINIMUM AIR GAP METAL STUD 1/2" MINIMUM FROM FIREPLACE TO NON- CLEARANCE FROM UNIT COMBUSTIBLE BACK WALL FACED TO CREATE AIR GAP-► BETWEEN UNIT AND NON-COMBUSTIBLE BOARD 2" MINIMUM AIR GAP BETWEEN UNIT AND NON- COMBUSTIBLE BOARD MINIMUM 1/2"THICK NON-COMBUSTIBLE BOARD Ll+ 4.0 • AIR INTAKE FOR DOUBLE GLASS UNITS ONLY SIZED BASED ON SIZE OF UNIT FOR MORE DETAILED FRAMING INFORMATION PLEASE REFER TO YOUR UNIT SPECIFIC FRAMING GUIDE RECEIVED 04/10/2023 69IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES WOOD FRAMING SPECIFICATIONS NON-COMBUSTIBLE FIRESTOP REQUIRED HEAT RELEASE 40" MINIMUM FROM TOP OF THE UNIT WITHIN 1-3" OF FIRESTOP SIZED BASED ON SIZE OF UNIT 111111111111111111111111111111111111.11111111.1111 I I 18" ABOVE FIREPLACE NON-COMBUSTIBLE ZONE- STEEL STUDS ONLY • FIRST, FLAT-FACED, METAL HEADER 1/2"MIN. CLEARANCE ABOVE UNIT _ 2" MINIMUM AIR GAP COVERED WOOD STUD 3" FROM FIREPLACE TO NON-COMBUSTIBLE BACK MINIMUM CLEARANCE FROM FIREPLACE SIDES AND SIDE WALLS MINIMUM 1/2"THICK 1111111M11.1. NON-COMBUSTIBLE BOARD simivormilm AIR INTAKE FOR DOUBLE GLASS UNITS ONLY SIZED BASED ON SIZE OF UNIT FOR MORE DETAILED FRAMING INFORMATION PLEASE REFER TO YOUR UNIT SPECIFIC FRAMING GUIDE RECEIVED 04/10/2023 70IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES 1. Floor clearance—The minimum clearance to floor is 1 inch, although the minimum telescopic legs retract to 4 inches below the fireplace.This means the legs may be set into the floor a maximum of 3 inches while maintaining the minimum clearance to the floor. Recessing the legs to the floor is not a recommended setup and should be avoided. NOTE: Install appliance on hard metal,cement board, drywall, or wood surfaces, extending full width and depth. WARNING! -DO NOT install directly on carpeting,vinyl,or any combustible material other than wood. J 2. Front clearance-Do not put furniture or any combustible objects within 36 inches(914 mm) of glass front of appliance. 3. Clearance to Metal frame—Clearance to metal frame is 1/2-inch (12.7 mm) minimum. In the chase,a metal header is required 18 inches above the fireplace if framing is needed.Above that,wood studs covered by non-combustible material are allowed.See the next page for details. 4. Minimum Combustible Clearances from Vent Pipe— • HORIZONTAL VENT PIPE CLEARANCES:A minimum clearance of 3 inches(76mm)to the top and 1 inch (25mm)to the sides and bottom of the vent pipe on all horizontal runs,to combustibles, is required. • VERTICAL VENT PIPE CLEARANCES:A minimum of 1 inch (25mm)around the vent pipe on all vertical runs,to combustibles, is required. Except for clearances in appliance enclosures. • Horizontal Vents must have a minimum 1/4 inch (6mm)rise per 1-foot run towards the termination. WARNING!-Never allow the vent to run downward.A downward slope can trap heat and become a possible fire hazard. WARNING! Maintain vent clearance to combustibles as detailed above. DO NOT pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe could cause overheating and fire. WARNING! Flare fireplaces are not designed to be load baring or support weight of any architectural framing. All framings should be self- supported,supported by back wall,side wall,or ceiling.Attempting to mount framing to a fireplace subjects'glass to unsupported weight and could result in damage to fireplace or breakage of glass. Improper framing or mounting to unit will void product warranty. Please consult Flare Fireplaces directly for additional questions or concerns about framing options. 5. Mantel Clearance—Combustible mantel clearance can vary according to the mantel depth and height. Use table and diagram on page 73 for guidelines on Mantel Installation RECEIVED 04/10/2023 711Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES 6. Fireplace shelf enclosure—The minimum height to the inside of a shelf above the top of the fireplace is 6 inches(12 inches above the glass).The shelf must be built with non-combustible material at least 5/8"thick. Due to the low size of shelf enclosure, it is recommended to build the enclosure using a Skamol board.The Skamol board is a light non-combustible material that can help prevent the formation of cracks and is a good insulator.The shelf enclosure MUST have an additional heat release opening centered on top of your shelf,as well as a standard heat release on the face or sides to make up for the additional heat we are creating in such a small space. See example below SHELF TOP VIEW f\\\\\\\\\\\\\\\\\\\\\\\\\\\\ 1 ADDITIONAL HEAT RELEASE ON TOP OF SHELF 7. Ceiling Clearance- The minimum ceiling height fora Flare Fireplace is 40"above the top of the fireplace. The heat release above the fireplace is critical for keeping the chase and surrounding walls at a relatively low temperature. 8. Minimum clearance to sides and back-Non-combustible—The minimum clearance from the back and sides of the fireplace to any non-combustible material (i.e., cement board or Type X fire rated board) is 2 inches.This clearance allows for proper air flow. 9. Minimum clearance to sides and back—Covered combustible_Combustible material at the back or sides of the fireplace, MUST be covered with non-combustible material that is at least 1/2 inch thick. Covered wood can be placed a minimum 3"away from the side and back. /„ Example:A non-combustible cement board is placed 2 1/2" inches from the back of the fireplace.The cement board used is%" inch . S thick. Combustible material can be used behind cement board as FIREPLACE F 2''A" m o it is a total of 3 inches away from the back of the fireplace and is o covered with a non-combustible material. - �y 3" 10. Minimum clearance to sides and back—Combustible—Clearance to combustible material at the back or sides of the fireplace, below the non-combustible line is 8".Please note this does not include minimum clearance directly above the fireplace inside the chase.Please see items starting at 12. 11. Minimum clearance directly above the fireplace inside the chase—non-combustible—All non-combustible studs to be installed a minimum of%"away from the fireplace. Metal studs should not connect to the fireplace or touch the fireplace. Doing so will result in heat transfer from the fireplace to the metal stud. Make sure not to block hot air flow to the heat release. RECEIVED 04/10/2023 72IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES 12. Minimum clearance directly above the fireplace inside the chase—Combustible • First 18"directly above the fireplace MUST be framed using non-combustible material. Metal Studs.Zone A • All combustibles above the 18" must be covered. Zone B. There should be no combustible materials left uncovered above the fireplace inside the chase. Fireplace chase should be designed and built to allow hot air to release from the unit and rise-up in a non-combustible channel to the heat release. • Covered combustibles allowed up to Fire-Stop 18 inches Metal Header area only Top of the Fireplace FjjPjce (16chjss) 13. Chase ceiling-Top of the chase must be covered with noncombustible material (Firestop). No exposed combustible materials are allowed inside the chase. RECEIVED 04/10/2023 73IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES 14. Hearth Clearances— A.Clearance to an uncovered combustible hearth below the glass is 2 inches as seen in EXAMPLE 1. B.When bringing your hearth to glass height it must be non-combustible for the first 7"extending from the glass before any combustible material can be used to finish the hearth.As seen in EXAMPLE 2 15. Adjacent Wall 1—Distance to any side adjacent wall must be at least 7 inches from the glass. As seen in EXAMPLE 1 EXAMPLE 1 ADJACENT WALL 7"CLEARANCE 2"CLEARANCE COMBUSTIBLE HEARTH EXAMPLE 2 ADJACENT WALL 7"CLEARANCE -41 11117111Mr COMBUSTIBLE HEARTH RECEIVE() 04/10/2023 74IPage ASPEN BUILDING DEPARTMENT 4 FLARE FIREPLACES 16. Finishing Around Front of Fireplace - Non-combustible finishing material (i.e., cement board, brick, stone,tile& minimum 1/2" inch Type X fire rated drywall) MUST be used to finish around the front of the appliance. Covered combustible material, can also be used to finish around the front of the fireplace, but only if the proper distance from the fireplace is maintained. Use example below to find proper distance. See Examples 1,2,and 3 below for further details. EXAMPLE 1 COMBUSTIBLE MATERIAL NON-COMBUSTIBLE MATERIAL I I iI t ABOVE FIREPLACE OPENING FLAT-FACE METAL STUD r1/2"MIN.GAP 6 ik 2"MIN. O If 18" NON—COMBUSTIBLE ZONE ____.--___,_ METAL STUDS ONLY i BELOW FIREPLACE OPENING /' [ I 4 i o e 2" MIN. O c , :,. CC1.1 I; c .o ff °_' ® " ® ':0' o 1 ,U � E ...... .„, ..... .------________________________----- o . 4/17,b23 75 P a e I g ASPEN BUILDING DEPARTMENT FLARE FIREPLACES EXAMPLE 2 COMBUSTIBLE MATERIAL NON-COMBUSTIBLE MATERIAL - ' I ' ABOVE FIREPLACE OPENING \ \ o . fl 1/2" 0 (MIN. 4.- • -,,, , , . , , . , , , METAL STUD . , . , . . . , 1/4"MIN. , •41-1•• 0 1/8"MIN. 1 • 4 4. , 4.5"to8"MAX 18" NON-COMBUSTIBLE ZONE ...._...„.„ ..., METAL STUDS ONLY ..... .- BELOW FIREPLACE OPENING ---, ,;/' ' :o On: . :0 ! e: , . . • ° , 11-1-11111H , , • , , 1 i , e " 1/8" MIN. , , I 1/2" W , MIN. I ° • +.1-1.— t 1'\ ° • is• • METAL STUD o ( . , , • • • 0 , , ; ss,s,„-----f .. , • , • ( , , , . • A I :,, , . . „ , , , , , :0 0: • :It'; 1: , • , I .. 0 „N 0 N II- Ill: ---------''' RECEIVED 04/10/2023 76IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES EXAMPLE 3 COMBUSTIBLE MATERIAL NON-COMBUSTIBLE MATERIAL ABOVE FIREPLACE OPENING \ FLAT-FACED METAL STUD 1/2" MIN. GAP oe ,,, lk O 1 __ 18" NON-COMBUSTIBLE ZONE ,• `. META_ STUDS ONLY 1 BELOW FIREPLACE OPENING ! 1 i . 1 i 1 :o o: • : p7, e: c)riiii : 1 0 ...., m -ii.ii o � C • r t . . Iss � . I . . • 0 C a , ss , . . . , ,,,„: : 11 o • . r m . • a c :a o°, o: ® ® :1 o I: c : °:: 9 • NOTE: DO NOT CONNECT MATERIALS TO OR DRILL INTO THE METAL FIREPLACE FRAME. THIS CAN RESULT IN EXCESSIVE HEAT TRANSFER AND/OR DAMAGE TO THE FIREPLACE AND SURROUNDING MATERIALS. RECEIVED 04/10/2023 77IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES CLEARANCES SPECIFICATION Non-Combustible Materials Specification Material which will not ignite and burn.Such materials are those consisting entirely of steel, iron, brick,tile, concrete, slate, glass or plasters,or any combination thereof. Materials that are reported as passing ASTM E 136,Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C shall be considered non-combustible materials. Non-combustible cement board approve must be at least 1/2"(13 mm)thick. Non-combustible material may be installed on the fireplace frame to cover the metal part as detailed in the installation examples and clarifications only if there is no weight transfer to the fireplace. Facing and/or finishing materials must never overhang into the glass opening. DO NOT connect materials to or drill into the metal fireplace frame.This can result in excessive heat transfer and/or damage to the fireplace and surrounding materials. All joints between the finished wall sheathing and the appliance must be sealed with non-combustible materials. WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Examples of noncombustible materials to be used: • Skamol Skamotec • Promat PROMAFOUR System 1/2"/12 mm, 5/8"/15 mm,3/4"/18 mm • James Hardie-Hardiebacker® 1/2"Cement Board • 1/2" or 5/8"Type X fire rated drywall.Type X gypsum board must comply with ASTM C1396 specification.Type X fire rated gypsum board can be used around the fireplace or at the back as a non-combustible material. 5/8"thickness is preferred because of better R-value. • Combustible Materials Specification Materials made of or surfaced with wood,compressed paper, plant fibers, plastics,or other material that can ignite and burn, whether flame-proofed or not,or plastered or un-plastered shall be considered combustible materials. RECEIVED 04/10/2023 78IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES MANTEL CLEARANCE Combustible mantel clearance can vary per the mantel size and location. Use chart and provided table for information on mantel install. Do not anchor any mantel or shelf to the fireplace. Only use metal studs above the fireplace as anchor points. Non-combustible mantels do not have a minimum clearance to the fireplace opening and can be brought as close to the glass as allowed by the frame of the fireplace. Please keep in mind any material used could potentially heat up dramatically the closer to the fireplace you bring it and the longer the fireplace is on. REF Height Mantel Depth A 2" 1" B 4" 4" C 6" D 10" 12" car -- ALL Jv Mantel Clearance table and example RECEIVED 04/10/2023 79IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES CLEARANCE TO SPRINKLER In a situation where a sprinkler head is installed within proximity to a Heat Release,the diagram below MUST be followed.The distance between the sprinkler head & Heat Release opening cannot be less than 60" in length at every point from the origin of the Heat Release.You must also verify the sprinkler head sensor is set to the proper heat setting so it does not activate when the room heats up from the fireplace being operated normally. DO NOT INSTALL A SPRINKLER IN THE FIREPLACE CAVITY. Please follow local building code to determine what temperature setting is relevant for your installation. 1 ceiling Sprinkler Head I'FIRESTOP AAAAAA 60"Minimum WARNING VAULTED CEILINGS CAN CREATE A CHANEL THAT FUNNELS HOT AIR DIRECTLY TOWARDS A SPRINKLER HEAD PLACED AT THE PROPER DISTANCE FROM HEAT RELEASE,AS STATED ABOVE.IF SPRINKLER HEAD SENSOR IS NOT RATED FOR HIGH HEAT IT COULD POTENTIALLY SET OFF THE SPRINKLER SYSTEM INADVERTENLY.PLEASE WORK WITH BUILDER&INSPECTOR TO VERIFY YOUR SPRINKLER SYSTYEM IS PROPERLY SET TO ACCOMMODATE HIGHER TEMPERATURES&IS NOT SET UP IN A HEAT CHANEL RECEIVED 04/10/2023 8OIPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES HEAT RELEASES All Flare Fireplaces(both safety screen and double glass units)require heat releases for warm air to flow back into the room. This controls the temperature of the surrounding walls, keeping them relatively cool. These relatively quiet blowers cannot be turned off and are required for the continued operation of your Double Glass system. Top Hot Release-The release/outlet for hot airflow from the wall enclosure MUST remain OPEN.The outlet must be at the top part of the enclosure but not necessarily at the front,so long as the measurements below are maintained. Heat release opening can be installed at the sides of the enclosure (one on every side), back or on top of(in case of a drop wall design). For fireplaces sized 80"& 100"—vent area must be at least 200 square inches OPEN AIR FLOW. For fireplaces sized 60"&70"-vent area must be at least 140 square inches OPEN AIR FLOW. For fireplace sized 50"and below-vent area must be at least 100 square inches OPEN AIR FLOW. The top of the outlet(s)must be at least 1" (25mm)down from the ceiling firestop,and no more than 3" (76mm) down.The vent can also be installed on top of the enclosure, as a drop wall (a chase that is not built all the way to the upper ceiling).Any opening greater than the minimum size is highly recommended and will help reduce the temperature of the surrounding walls.Make sure a non-combustible fire stop is placed atop the inside of the chase and is framed in a way that does not allow any pockets of heat to be formed.All rising heat should be able rise to the fire stop and freely flow though the heat release opening into the room. AIR INTAKE Required for installation with double glass or safety screen with optional blower kit.This allows air circulation which cools the external glass and increases the efficiency of the fireplace. Lower Air Intake-Optional for normal safety screen installation. Required for installation with double glass or safety screen with optional blower kit. For fireplaces sized 80"& 100"—vent area must be at least 100 square inches OPEN AIR FLOW. For fireplaces sized 60"&70"-vent area must be at least 70 square inches OPEN AIR FLOW. For fireplaces sized 50"and below-vent area must be at least 50 square inches OPEN AIR FLOW. FOR SEE THROUGH AND ROOM DEFINER FIREPLACES,THE AIR INTAKE SIZE REQUIREMENTS ARE DOUBLED.THIS CAN BE ACHIEVED BY OPENING UP MULTIPLE SIDES EQUALLY,OR BY DOUBLING THE OPENING ON THE LONGEST SIDE. NOTE:Openings above for Heat Release and Air Intake are measured for open air space.The fans for the Double Glass cannot be turned off during operation. Lower vent opening can also be used as an access door to the gas valve if it meets both requirements in terms of size. Lower vent opening can be installed at the sides of the enclosure(one on every side), back or front. It is recommended to place one opening on either side of longer units,to allow for better distribution across all fans of air taken in from the bottom. NOTE ***VERTICALLY ORIENTED HEAT RELEASES ARE NOT ACCEPTABLE,AND WILL LEAD TO OVERHEATING*** ALL VENTILATION OPENINGS MUST BE INTERIOR FACING TO AVOID EXPOSING THE INDOOR FIREPLACE AND COMPONENTS TO EXTERIOR ELEMENTS. RECEIVED 04/10/2023 811Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES EXAMPLES OF HEAT RELEASES Classic Drop Registers Wall Openings at the front, sides, The wall does not reach to or back(pick one or more) the ceiling and is left open can be covered with vent on top. registers. It is possible to heat multiple rooms this way. ono Shadow Line A recess hides the opening at the top for heat release or at the bottom for air intake (for Finished Shadow Line Heat Release double glass units). Top Shadow Line _ ■■■summons _ ■■1111ww ■U NV■ 1 —11a FIVER Bottom Shadow Line 04/10/2023 82 I P a g e ASPEN BUILDING DEPARTMENT FLARE FIREPLACES The Flare Fireplace is a finely tuned machine that operates at the highest of standards.To get the most out of your Flare Fireplace installation please see the following suggestions for optimal performance and functionality. KEEPING THE WALL ABOVE YOUR FIREPLACE AS COOL AS POSSIBLE The Flare Fireplaces installation guide calls for,and clarifies,the minimum requirements for a heat release in your build to make sure your fireplace operates within the safely set nationwide guidelines for direct vent fireplaces.To make sure the wall above your Flare Fireplace is as cool as possible, Flare suggests enlarging your heat release to increase how fast the heat created in your fireplace cavity is evacuated into the space.The faster heat can evacuate the cavity above your fireplace the cooler your wall will be. Flare offers many ways to implement a heat release that mask its existence,allowing you to increase its size dramatically without ruining the visual aesthetic(SEE SECTION REFERENCING EXAMPLES OF HEAT RELEASES AND AIR INTAKES IN FLARE INSTALLATION MANUAL). For example,if you are installing a Flare Fireplace with a 50" length you will need a minimum of 100 SQ "of open-air flow to evacuate your cavity successfully. But by meeting the minimum specification allowed,the wall temperatures will remain safe but at the higher end of the spectrum allowed for these style fireplaces. By implementing a shadow line heat release as close as 3"from your ceiling you can increase the opening by more than double to create a cavity that evacuates heat at a much faster rate.Allowing for a wall that reaches temperatures well below the minimum standard required for safe operation. - SHADOW LINE FRAMING • ETED SHADOW IIIXAMPLE 3" FROM CEILING tot: --- �� _ • / (Ij r y, • 5 RECEIVED 04/10/2023 83IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES KEEPING YOUR DOUBLE GLASS AS COOL AS POSSIBLE The Flare Fireplaces installation guide calls for,and clarifies,the minimum requirements for the air intake sizing on your double glass fireplace build, making sure your fireplace operates within the safely set nationwide guidelines for direct vent fireplaces.To get the outer layer of glass on your double glass equipped Flare Fireplace as cool as possible, Flare suggests enlarging your air intake and heat release to increase the amount of room temperature air being pulled in cycled through the system.The more room temperature air the silent intake fans can pull between the two panes of Double Glass,the cooler your outer layer will be. Flare offers many ways to implement an air intake that mask its existence,allowing you to increase its size dramatically without ruining the visual aesthetic(SEE SECTION REFERENCING EXAMPLES OF HEAT RELEASES AND AIR INTAKES IN FLARE INSTALLATION MANUAL). For example, if you are installing a Flare Fireplace with a 50" length you will need a minimum of 50 SQ"of open-air flow to cool your double glass successfully. But by meeting the minimum specification allowed,the glass temperatures will remain safe but at the higher end of the spectrum allowed for these style fireplaces. By implementing a shadow line air intake(ALSO KNOWN AS A FLOATING HEARTH)as close as 3"from your floor,you can increase the opening by more than double to create a cavity that evacuates heat at a much faster rate.Allowing for an outer layer of glass that reaches temperatures well below the minimum standard required for safe operation. AIR INTAKE INSTALLED AS FLOATING HEARTH. PANEL IN FLOATING HEARTH �'s # � THAT IS PARALLEL TO THE FLOOR IS WIDE OPEN,ALLOWING FOR MUCH MORE AIR FLOW ` 411111114111001:4 RECEIVED 04/10/2023 84IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES FLARE FRONT, SEE THROUGH, AND CORNER FIREPLACE CLEARANCE FLAT — SIDE AND ISOMETRIC VIEW Combustible A �� 7.<11\ifi � Non-Combustible i 1 1 i yl /111 p G E F • • ~ H Warning! —Maintain open Air flow between the fireplace and drywall. Make sure cables or any other materials are not blocking hot air flow. RECEIV D 04/10/2023 85IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES A.Top Vent system-Hot Airflow outlet from the wall enclosure MUST remain open.The outlet must be at the top part of the enclosure, but not necessarily at the front, if the measurements below are maintained. For fireplaces sized 80"& 100"—vent area must be at least 200 square inches OPEN AIR FLOW. For fireplaces sized 60"&70"-vent area must be at least 140 square inches OPEN AIR FLOW. For fireplace sized 50"and below-vent area must be at least 100 square inches OPEN AIR FLOW. B. Open air flow for hot air to rise from the fireplace to the top of the enclosure.The enclosure can be supported by studs, but open-air flow MUST be always maintained. In case needed, insulation for electric wires or systems may be added but it is important to keep most of the air flow open. Never place any insulation on the fireplace. C. Metal Stud below non-combustible material line. Below non-combustible line,all studs used should be metal type. No studs to be connected to the fireplace frame (1/2 Inch clearance). Open hot airflow MUST be maintained and should not be blocked. Note:Max recess of TV cavity should not exceed 6".Recesses exceeding this dimension run the risk of creating a shelf and hindering air flow above unit,resulting in a wall that may overheat. D. Non-combustible material is placed flat on the front fireplace support bracket.The support bracket holds the fire-rated, non-combustible, material and allows hot air to rise from the glass into the fireplace enclosure. Hot air is to be released into the room using the top static vent opening. The fireplace enclosure must allow air to rise and circulate from the top of the fireplace glass(from lower vent opening),to be released back to the room from the top. To increase heating,the enclosure should prevent hot air from being released to the attic by venting it back to the room using the static vent system (A). Non-combustible stud MUST NOT be connected or drilled into the fireplace frame. Drilling into the fireplace frame can result in damage to the fireplace. E.Cold air,drafted from the room through the lower static vent, (G)flows up and is heated by the fireplace.The Cold air gap should remain open to allow air to flow up and exchange heat with the fireplace.The fireplace can be installed with double glazing glass system or safety screens. Blower system may be used to push cold air up(F). F. Heat exchange blowers are optional when fireplace is installed with safety screens. Heat exchange blowers must be included when installing a double-glazing fireplace.The blowers are designed to move cold air from the room using the lower vent opening(G)up against the fireplace glass.As the air flows on the glass,it is heated and released back to the room from the glass front and from the top(A)vent opening. G. Lower vent opening. OPTIONAL for normal installation. A MUST for double glass installation or blower kit option. For fireplaces sized 80"& 100"—vent area must be at least 100 square inches OPEN AIR FLOW. For fireplaces sized 60"&70"-vent area must be at least 70 square inches OPEN AIR FLOW. For fireplaces sized 50"and below-vent area must be at least 50 square inches OPEN AIR FLOW. FOR SEE THROUGH FIREPLACES THE AIR INTAKE REQUIREMENTS ARE DOUBLE, EQUAL ON BOTH SIDES. H.Adjustable fireplace legs. RECEIVED 04/10/2023 86IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES L SHAPE — SIDE AND ISOMETRIC VIEW A j CorinbuStlble Non-Combustible \ ,1\i L , „Min 1"Min f C Po Z" 14111110 legmmeN— • G -•14 ` F • I :40- H I- WARNING! Maintain open air between the fireplace and drywall. Make sure cables or any other materials are not blocking hot air flow. RECEI EC) 04/10/2023 871Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES A.Top Vent system-Hot Airflow outlet from the wall enclosure MUST remain open. For Flare See Through fireplace, open vent must exist in both sides of the glass.The outlet must be at the top part of the enclosure but not necessarily at the front if the measurements below are maintained. For fireplaces sized 80"& 100"—vent area must be at least 200 square inches OPEN AIR FLOW. For fireplaces sized 60"&70"-vent area must be at least 140 square inches OPEN AIR FLOW. For fireplace sized 50"and below-vent area must be at least 100 square inches OPEN AIR FLOW. B. Open air flow for hot air to rise from the fireplace to the top of the enclosure.The enclosure can be supported by studs, but open-air flow MUST be always maintained. In case needed, insulation for electric wires or systems may be added but it is important to keep most of the air flow open. Never place any insulation on the fireplace. C. Metal Stud below non-combustible material line. Below non-combustible line,all studs used should be metal type. No studs to be connected to the fireplace frame(1/2 Inch clearance). Open hot airflow MUST be maintained and should not be blocked. Note:Max recess of TV cavity should not exceed 6".Recesses exceeding this dimension run the risk of creating a shelf and hindering air flow above unit,resulting in a wall that may overheat. D. Non-combustible material is placed flat on the front fireplace support bracket.The support bracket holds the fire-rated, non-combustible, material and allows hot air to rise from the glass into the fireplace enclosure. Hot air is to be released into the room using the top static vent opening. The fireplace enclosure must allow air to rise and circulate from the top of the fireplace glass(from lower vent opening),to be released back to the room from the top.To increase heating,the enclosure should prevent hot air from being released to the attic by venting it back to the room using the static vent system (A). Non-combustible stud MUST NOT be connected or drilled into the fireplace frame. Drilling into the fireplace frame can result in damage to the fireplace. E.Cold air,drafted from the room through the lower static vent, (G)flows up and is heated by the fireplace.The Cold air gap should remain open to allow air to flow up and exchange heat with the fireplace.The fireplace can be installed with double glazing glass system or safety screens. Blower system may be used to push cold air up(F). F. Heat exchange blowers are optional when fireplace is installed with safety screens. Heat exchange blowers must be included when installing a double-glazing fireplace.The blowers are designed to move cold air from the room using the lower vent opening(G)up against the fireplace glass.As the air flows on the glass, it is heated and released back to the room from the glass front and from the top(A)vent opening. G. Lower vent opening. Optional for normal installation.A Must for double glass installation or blower kit option. For fireplaces sized 80"& 100"—vent area must be at least 100 square inches OPEN AIR FLOW. For fireplaces sized 60"&70"-vent area must be at least 70 square inches OPEN AIR FLOW. For fireplaces sized 50"and below-vent area must be at least 50 square inches OPEN AIR FLOW. FOR SEE THROUGH FIREPLACES THE AIR INTAKE REQUIREMENTS ARE DOUBLE, EQUAL ON BOTH SIDES. H.Adjustable fireplace legs. RECEIVED 04/10/2023 88IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES SIDE OVERHANG SPECIFICATION ON LEFT, RIGHT, & DOUBLE CORNER FIREPLACES When installing a Left, Right, or Double Corner fireplace with left and right non-combustible overhangs, please follow the specification outlined below to maintain a safely operating fireplace and surround. - First 18"of framing above the fireplace must be metal studs. - All finishing materials within and above this glass recess must be non-combustible - At no point can your overhang reach down into the viewing area. - There is no maximum distance for overhangs on the left or right side of the fireplace. SIDE OVERHANG SPECIFICATION FOR LEFT, RIGHT, & DOUBLE CORNER STYLE FIREPLACES NO MAXIMUM 1111111 NO MAXIMUM RECEIVED 04/10/2023 89IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES INDOOR/OUTDOOR KIT The following installation information is used for the Flare Fireplace outdoor kit. The outdoor window kit can only be used with Flare Front, Flare See Through, and the Flare See Through Passage fireplaces. The Flare outdoor kit is installed like a window and must be weatherproofed on all sides. It must include an overhang or cover to protect the face from exterior elements. All fireplace clearances must be followed when installing a Flare Fireplace next to this outdoor window kit. OUTDOOR KIT INSTALLATION CONSIDERATIONS Because the outdoor kit only adds weather resistance the face of an interior fireplace, a weatherproof enclosure is required for the unit and its components. It will also need the openings for your heat release, and if using double glass, air intakes to face the interior of the build, and only install these units with the proper overhang or roof considerations. This will help with the long-term protection of your fireplace and its components. Below are other examples of elements to consider for your outdoor kit equipped fireplace. • The fireplace must be installed in a completely weatherproof enclosure, with one interior facing wall. • The outdoor kits are made from a high-quality black painted stainless steel and are weather resistant on the front window only. • All fireplace controls and gas components must be installed in a weatherproof enclosure. • The outdoor kit can occasionally tolerate small amounts of water but is not waterproof. • The fireplace must be enclosed in a weatherproof enclosure covered in typical weatherproof material, such as siding/stucco/stone/tile, etc. and have a weatherproof structure to shed water that extends horizontally beyond the front and side perimeter of the fireplace. • Water running down vertical surfaces should be directed away from the fireplace using flashings. Measures must be taken to ensure any accumulated water drains away from the fireplace and structure. • When the fireplace is installed on surfaces where water may collect or cause damage, a suitable drainage pan should be placed under the unit and the water drained away. • Do not use the remote-controlled handset supplied with the appliance. The use of the thermostat on the remote may result in continued operation of the fireplace. • Exposure to outdoor sun - Exposure to outdoor sun light will cause some painted finishes to fade over time. Fading is unavoidable and not covered under warranty. Minimize fading by installing the fireplace away from direct sunlight. • Make sure the fireplace is fully turned off when attempting to clean the front of the fireplace (including pilot). RECEIVED 04/10/2023 90IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES OVERHANG REQUIREMENT A weatherproof overhang in front of the fireplace is 1/2 the height of the fireplace face-wall, measured from the base of the unit to the ceiling. Overhang 1 2 Outdoor Window Kit f ' RECEIVED 04/10/2023 91IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES OUTDOOR KIT FRAMING AND FINISH All studs and surrounding material should follow the fireplace clearances and non-combustible requirements Z Wood stud with Non Combustible back wall: ‘sliiii*.....**'Ll*PN --"".., '1"••••.441 ,_ i Covered with Non- Cl/ ombustible t I ► __,_ , ffr Steel Studs X 111 Non -Combustible Board OUTDOOR KIT CLEARANCE TO NON-COMBUSTIBLE WALL iii: 1 vz 0 INDOOR 0 M 7 7:. 41 j— _ ; MI: :- , [7' min.] i�= ////////A 51 min. •. OUTDOOR RECEIVED 04/10/2023 921Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES OUTDOOR KIT OPENING DIMENSIONS Cement Board Wall [2rnax.1 , [81 4 min.] 60 max. /, 210 min. L 1/ t i ' 1 External Opening Dimensions H L Inch 20 43 13/-6 4,5 mm 508 1113 Inch 20 50 8/16 50 mm 508 1283 Inch 20 60 5/-6 60 mm 508 1783 Inch 20 70 3/15 70 mm 508 1783 Inch 20 82 12/16 80 mm 508 2102 Inch 20 99 17-6 100 mm 508 2532 Use the Flare architectural guide for information on the window size and opening:http://flarefireplaces.com/portfolio-items/flare-outdoor/ RECEIVED 04/10/2023 93 l P a g e ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES WEATHER-PROOF YOUR OUTDOOR KIT CAVITY The outdoor window kit should be sealed with non-combustible tape, around the inner most flange, prior to covering with brick or stucco. All non-combustible finishing material can come directly to the outer-most flange around the face of the fireplace. Creating that frameless appearance around your opening. t �L ' . c J y 1 i RECEIVED 04/10/2023 94IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES BURNER DIMENSIONS i BURNER TYPE SIZE (cm) SIZE (in) FIREPLACE SIZE #OF BURNERS A 55 cm 21 11/16" 30" 1 B 80 cm 31 12/16" 45" 1 C 105 cm 40 1/16" 50" 1 D 125 cm(35 cm,55 cm,35 cm) 50 1/16"(14",22",14") 60" 3 E 150 cm(35 cm,80 cm,35 cm) 59 15/16"(14",32",14") 70" 3 F 175 cm(35 cm,105 cm,35cm) 68 4/16"(14",40",14") 80" 3 G 215 cm(55 cm,105 cm,55 cm) 84" (22",40",22") 100" 3 ***For updated product dimensions and framing information,please visit Flare's PRODUCT PAGE,navigate to the product of your choice,scroll to four tabbed charts,&click"DOWNLOAD CENTER". *** RECEIVED 04/10/2023 95IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES HOME AUTOMATION A Flare Fireplace can be operated through an external source (See cautionary remark below) such as a smart home (home automation) system by using the 6- pin connector on the SIT receiver X8 port in place of the included Wall Switch. The existing Flare Fireplace wall switch cable must be used to connect the receiver to the home automation system. The existing Flare Fireplace wall switch cable can be located by removing the included Flare Fireplaces wall switch, exposing the wire provided, and replacing it with a dry contact On/Off relay controlled by the home automation system. The existing Flare Fireplace wall switch cable can be extended up to 100 FT for integration into a new or existing Home Automation System. Please contact Flare Support for additional information on appropriate relays to be used. 1. The included Flare Fireplaces Wall Switch 2. An example of the exposed wall switch with cables used Can be seen in the example below to connect to dry contact On/Off relay can be seen below. -4 /4, f; 3. Remove the physical switch exposing 4. Use exposed cables to connect your system to dry your wires as seen below contact On/Off relay and tie into home automation or smart product. 14 CAUTION DO NOT CONTROL FIREPLACE FROM OUTSIDE OF HOME USING EXTERNALLY CONNECTED DEVICE. ONLY OPERATE 3RD PARTY APPLICATION OR HOME AUTOMATION WHEN YOU CAN PHYSICALLY SEE THE FIREPLACE TURNING ON & OFF. IT IS NOT MEANT TO OPERATE WITHOUT LINE OF SIGHT TO FIREPLACE RECEIVED 04/10/2023 96IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES ELECTRIC AND CONTROL ELECTRIC DIAGRAM - SCREEN - Wall switch/Home Automation connects directly to X8 port. - X4 port is always closed circuit. - SIT 110v will be powered by home wall socket. � 1111 • /� :'S �I ro g■ ar7 !INp � ' (e oJj124' 4 X9 X8 X7 X6 X5 X4 X3 X2 X13 X11X10 X1 ][OOOOflOD0 ; x,t I v ICIN‘ Wall Switch �U •fi7 AC 110v SIT System power X1:Green=Ground White=Common Black=Line RECEIVED 04/10/2023 97IPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES DIAGRAM - DOUBLE GLASS AND POWER VENT • Aux port(X13) is used as switch to open and close the relay port of the control system (To activate and deactivate the control system) • ON/OFF switch(X4) are controlled via the Flare Control system �t1W' • ARt EIIIE/LAC(I 1 ILARI EIRUP I LACE ,�'� , .,"N"L 1 1. l..t IrI. 1�.I AC in 110V _.1... ADANGER L �L . ( . , • , ,--- , .........Venaff• wrinorr.....fter I t I :I.daft Wall Switch illI o0 • IEl n P1 o 7 V � l o pl g 1 X9 X8 X7 X6 X5 X4 X3 X2 i i I 1 X13 X11 X1'0, ..r�C00OJ� X1 II x. Relay cable x13 T-6 ►- _.- 1 • t ► j r i s SIT system AC in 110V X1:Green=Ground White=Common Black=Line RECEIVED 04/10/2023 98lPage ASPEN BUILDING DEPARTMENT FLARE 4 FIREPLACES DOUBLE GLASS BOARD & LED LIGHT GUIDE r ��' �t 111111P 3 m a „s \lip ug E$QE LED '-POWER VE r LED U9: 11,• u. _�. -.TTlJnc '.' ■ P ® .1 < 4 C L J , _ CND° - • I�L E — __ f '1 , T � E �r.Z1 � II,'' • ohms CE1 b �_ ��- .t 1KL•. - _I .L_- Il Conform 10 61556-]-6 Y Kz s <_< sK 7Sl<F-fin- ._ :g -"JERT�: •$ems= LSi KK Alw W. + - -1.0 . _ 7 +gam-'-,er-'- o R 24 - - K�.a-Fb,. --�fi�=a te= 52 s..ve-L.�§e- .t_ 3 amas s.g�?�1e{ 1^. a3E-jO01O©0® g . F. --,B 'vaE E—s>g.-r i-^a.i 1 I a 80r©©C0®_ I sew-3 ^?0ae:.--Y g :7e$ -olf F � 'o T ' F + L io F ?cse-E io5° . -+`- [.-1.--}ej1 '1 '1 1 I r{ E I J2 J3 c 'ry JS ( per. Se ._:1 C E+Ele 7aEt4- ;Fete{-74o$e4-!' 1 2 3 , 4 5 6 7 B 9 10 11 12 - �' 000 b ® ®®0 Y + iN.— O N ��!I D�S TO•. "r:.z..s:1 _ -.� I12] 1ol[811 .1 jwEli t a, i3: 11111 . 117115113111Jr 0 1 2 8 4 5 6 7 E3 \,:ib 1.. 1.... .� .<... -.. ..• r� ... FAN BYPASS SWITCHES&LEDs IA L, (***NUMBER OF FANS CAN CHANGE BASED ON MODEL SIZE***) ; J c l .1.1�='�1/'� � The dipswitches, in the"FAN BYPASS"area r• - � of the Double Glass Board,are used to IrT f . _ i - S O determine what fans will be monitored by the board,verifying all fans are (V iziagsgir,rr isindeed working properly before allowing the fireplace burner to start.Turn3L 2 4 6 6 7 Et the switch ON (UP)to bypass monitoring of fan number of your choice, &OFF (/) (DOWN)to begin to monitor fan activity. If no fan is present,set switch to on i -- -_ '�J CO so it will bypass the need to verify fan activity.The switches are numbered to CA O N (� correlate with the LED lights they are associated with above.The final switch r— r— is the"Master Bypass"option.Turning this on bypasses all checks to the fant)I system&Power Vent. FAN LED INDICATORS A. Red-Fan is not connected or malfunctioning. B. Off-Fan is being bypassed. C. Green-Fan is running properly. POWER LED INDICATOR The Red Power LED lets you know the board is receiving power. POWER VENT LED INDICATOR The Blue Power Vent LED lets you know the Power Power-Vent is properly sending&receiving signal to the board. FAN&POWER VENT REQUEST LED The White LED indicates the GV60 has requested to start the fans& Power Vent, if connected. RECEIVED 04/10/2023 99IPage ASPEN BUILDING DEPARTMENT FLARE FIREPLACES ELECTRIC DIAGRAM — PV SYSTEM PV Control Board GND _ + GND _ PV 1 Fan U U U 11OV AC U U U Cool Fan 1 G 44 43 42 41 40 39 110V AC Input o _ A + C 49 48 47 X 46 45 U - DC6V El 11 U White Black Green FlowSense I To Fireplace Board 6V DC - 3 line wire Ports 49-47 are connected to J6 on fireplace main board. RECEIVED 04/10/2023 100 ( Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES REPLACEMENT PARTS See below for flare replacement part list. • Please contact your fireplace dealer to purchase any replacement part. • Please make sure to provide the description and part number. • Please make sure to use a certified installer for any service related to your fireplace. FLARE FIREPLACES I GENERAL PARTS-GV60 PART _ _ DESCRIPTION SKU GV60 Complete System Gas Valve System,Receiver,GV60 Wiring 1GVCGS 2 Way-Receiver-GV60-Green GV60 Receiver-Green Stickered 1GVRCG 2 Way-Receiver-GV60-Blue _ GV60 Receiver-Blue Stickered 1GVRCB Power Adapter 6V DC Power Adapter For Receiver 1OGVPA 2 Way-Remote-GV60-Blue GV60 Remote-Blue Stickered 1GVWSC GV60 Wallswitch 20'Cable to Receiver lOGVWS Home Automation Cable _ 20'Cable 1GVHAC GV60 Gas Valve Gas Valve,Thermocouple House,Inlet/Outle Gas Fittings lOGVGV Thermocouple Valve Housing - Black Plastic Housing for Thermocouple Valve _ 100PTP 1/2"Inlet Gas Fitting - Flare Fitting for Gas Valve Inlet 1GV121 3/8"Inlet Gas Fitting _ Flare Fitting for Gas Valve Outlet 1GV381 Data Cable _ GV60 8-Pin Data Cable 1GV8DC Red Cable _ GV60 Thermocouple Cable 1GVTRC Yellow Cable _ GV60 Switch Cable 1GVTYC WiFi Cable WiFi Module Cable 1GVWFC Pilot Assembly Pilot Housing,Spark Cable,Spark Ignitor Electrode, 100CPA Thermocouple,Pilot Gas Line,Orifice NG(or LP if specified) Pilot Housing Housing for Pilot Assembly 1000PH Spark Cable - GV60 Spark Cable _ 100PSC Spark Ignitor Electrode _ Electrode Used in Spark Ignitor 100PSP Thermocouple _ Fitting to Thermocouple Valve Housing 100PTH Pilot Gas Line Fitting to Gas Valve 100PPT Pilot Orifice NG Natural Gas Pilot Orifice 1PORNG Double Glass Solenoid _ Solenoid Replacement For Double Glass Units 100DGS Pilot Orifice LP Liquid Propane Pilot Orifice 1PORLP Control System _ For units with Double Glass,Power Vent,SK ONLY:Control Box 1ODGCB Control Power/Relay Cable _ From board to plug,plug to power and relay 1GVCPRC Control Receiver Cable _ _ From board to plug,plug to yellow and red 1GVRC Control PV Cable Cable with connection to board 1PVCBS Control SK Cable Cable with connection to board 1SKDGC Control LED Cable _ Power plug with connection to board 1RGBPC LED Power Supply 24V DC power supply 1RGBPS LED Wiring Harness Y-shaped wiring harness from LED strips to controller 1RGBYC RBG LED Controller RGB Controller and Remote 1RGBCR RGB LED Strip _ RGB LED Light Strip 1RGBLS PV High Voltage Cable 50 feet PVCBLHV SK High Voltage Cable _ 50 feet SKCBLHV Suction Cups _ 2 suction cups 1GVCUP Narrow Glass Gasket 3/8"Wide GASKN Wide Glass Gasket 5/8"Wide GASKW 8"DG Fan Replacement 8"Fan used in Double Glass Fireplaces 10DGEF RECEIVED 04/10/2023 101 ( Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES diiiiiiiii WARNING! • It is recommended that a qualified service technician perform a routine inspection at the beginning of each heating season. • Disconnect power before attempting maintenance or repair of the fireplace. • Installation and maintenance must be performed by an authorized qualified installer, service agency or gas supplier. • Any safety screen or guard removed for servicing placed back before operating this appliance. • DO NOT USE this appliance if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas valve that has been under water or impacted. • Any alteration to the product that causes soot or carbon to form and results in damage is not the responsibility of the manufacturer. • Do not modify or substitute any part of this appliance. • Inspect the external vent cap on a regular basis to make sure that no debris,plants,trees, or shrubs are interfering with the air flow. • Do not operate the fireplace without the fireplace glass. • It is imperative that control compartments, screens, or fans system for double glass be kept clean and free of obstructions. These areas provide the air necessary for safe operation. • Light the heater using the built-in igniter. Do not use matches or any other external device to light your heater. • Never remove,replace, modify, or substitute any part of the heater unless instructions are given in this manual.All other work must be done by a trained technician. Do not modify or replace orifices. RECEIVED 04/10/2023 102 ( Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES Yearly Service-Commercial fireplaces may need to be serviced more frequently depending on usage. Failure to inspect and maintain the fireplace may lead to improper combustion and a potentially dangerous situation. We recommend the following procedures be done by a qualified technician. Glass Maintenance • Always use suction cups to remove the fireplace glass. Use the manual procedure for instruction on how to remove the fireplace glass.Always use gloves when removing the glass to protect your hand and prevent fingerprints on the glass. • DO NOT USE abrasive cleaners on the glass panels. DO NOT ATTEMPT to clean the glass panels when they are hot. • Do not use normal household(usually ammonia-based)glass cleaners to clean the glass as these cleaners can leave a permanent stain. Only a gas fireplace glass cleaner should be used. • Verify no cracks or breakage in the glass. • Place glass in a safe location to prevent breakage. • Never attempt to operate the fireplace without the fireplace glass. Pilot Maintenance • Visually inspect the pilot flame.The pilot flame should be always present when the fireplace is in operation. • Make sure the pilot flame has two flame tips pointing to the flame sensor(thermocouple)and to the center of the burner. • Make sure the pilot area is clean from any dust, media or any other debris that may disrupt the operation of the ignition system. Lint or foreign material must be removed with a brush or vacuum. • Verify fireplace ignition using the remote or wall switch.Verify electronic ignition,sparking sequence, pilot operation and burner ignition. Burner Maintenance • The flames from the burner should be visually checked.The flame should have a blue base and yellow tops and be candle- like in appearance. • If excessive soot is found inside the firebox area, the fireplace will require adjustment. Verify the air shutter and vent restrictor setting and document any changes. • If the flame becomes sooty, dark orange in color, or extremely tall,do not operate the heater. • Measure gas pressure. Inlet W.C., Outlet W.C. Vent Maintenance The following venting system inspection by a qualified service technician is recommended every six months: • Inspect for excessive condensation, e.g., water droplets forming in the inner lining and subsequently dripping out of the joints.This can cause corrosion in the system. • Check for corrosion in areas exposed to the elements.Where rust spots or holes have appeared,these must be immediately replaced. • Ensure that there is no foreign material in the vents.Survey by removing the cap and shining a light down the vent. • Check all joints and pipes to make sure that nothing has been disturbed or loosened. Double Glass Fans • Disconnect power to the Flare control system. • Remove the external glass and the covering trim. • Inspect the fans around the Flare firebox and make sure they are all turning. • Clean all fans with a brush and vacuum to remove any dust or debris. • Inspect the lower fireplace intake. Clean the lower vent intake with a brush and vacuum any dust or debris. • Connect back the Flare control power and press the Flare remote arrow down. Make sure all fans are working properly. • Turn off the fans and install back the trim and glass. RECEIVED 04/10/2023 103 ( Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES TORUBLESHOOTING ADJUSTING YOUR AIR SHUTTER TO PREVENT SOOTING The correct fuel-air mixture in your Flare Fireplace produces yellow flame tips, with blue base and offers minimal soot buildup. The Fuel-air mixture is set by the factory, but may need adjustment by fireplace installer, depending on site conditions. 1. Identifying and locating the air shutter on your Flare Fireplace. EX 1:AIR SHUTTER ON INSIDE OF FIREPLACE ON THE BURNER EX 2:AIR SHUTTER ADJUSTMENT UNDER YOUR FIREPLACE a 40 4140 4P 4, 4W 4W 4W 4W 40 4D 4W 4W 4, 4 POQ ® o ® ov • .- .T ITT -70O • • •""' 100 •41- • , • Example 1: If the fireplace has been completely installed, and no access can be had to the underside of the fireplace,the adjustment can be done from inside the fireplace, on the burner. Each burner(up to three burners, on units 60" and above) has a +and—sign located on it. In between that+ and—sign is a Philips head screw that can be turned to either increase or decrease the air to gas mixture. See Ex. 1 above for visual. • Example 2:The second option allows you to adjust your Flare Fireplaces air shutter by accessing it from directly underneath the fireplace. See Ex. 2 above for visual. FOR CLARITY ON HOW YOUR ADJUSTMENTS IMPACT THE FLAME COLOR AND SOOTING PLEASE CLICK THIS LINK TO WATCH AN ELABORATE AIR SHUTTER VIDEO Adjust the Air shutter if the Air to Fuel mixture is not correct: • Flame is Yellow or orange producing soot (low air leading to a rich flame) - Introduce more air by turning clockwise. • Flame is very blue (too much air) - Reduce the air by turning counterclockwise. Common reason air shutter adjustment may be needed: • LP conversion has been done. • High above sea level installation. High elevation with low oxygen in the air. • Soot buildup on the glass or termination cap In all cases, it is recommended to verify inlet pressure to match recommended values, in addition to setting the air shutter on the burner. RECEIVED 04/10/2023 104 I ASPEN BUILDING DEPARTMENT FLARE FIREPLACES APPENDIX MAINTENANCE LOG Flare Fi replaces — Maintenance log The following document should be used by the service technician.A copy should be kept with the technician and owner for future reference. Service Date: Unit Information Model Type and Size: Serial#: Owner Information Name: Address Technician Information Name: Company Name Technician NPI# Service Information Yearly Maintenance: Other: Details: RECEIVED 04/10/2023 1051Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES WARRANTY POLICY Flare Fireplaces subjects every fireplace and component to rigorous testing to verify it is free from any defects before it leaves our warehouse. Flare Fireplaces photographs and documents the fireplace and all components' moments before shipping them to our nationwide network of authorized dealers for installation,verifying full operation of the fireplace and all components. Our factory is supervised by CSA and subject to the highest operating standards. 18 MONTH COMPREHENSIVE WARRANTY Effective beginning 18 months from the original date of purchase from an authorized Flare Fireplaces Dealer, our Comprehensive Warranty includes replacing or repairing any defective electronic components.These parts include the following components: • Gas Valve • Receiver • Remote • LED Lighting Strips, Remote,&Controller • Authorized Media • Wall Switch This warranty does not apply to any component that shows evidence of misuse, abuse, improper installation,exposure to water or moisture,excessive heat,dust, or paint. LIMITED FIVE-YEAR COVERAGE Effective for five years from the original date of purchase, Flare Fireplaces Limited Five-Year Coverage includes replacing both ceramic and tempered glass.This coverage is warrantable under the following circumstances: • Thermal Breakage Only This coverage is void if the glass is damaged due to construction, improper, storage, pitting,transport, handling, or cleaning.This includes using ammonia or detergent based cleaning-solvents or solutions instead of lukewarm water and a lint free cloth.Other products may leave streaking or a honeycomb shaped stain on your fireplace glass. LIMITED 10-YEAR COVERAGE Limited Lifetime Coverage is extended to the following components: • Firebox • Burners RECEIVED 04/10/2023 106 ( Page ASPEN BUILDING DEPARTMENT FLARE FIREPLACES CONDITIONS • Warranty coverage begins on the date of original purchase. • Minor warping of certain components or discoloration is normal and is not considered a defect that is covered under this warranty. Major disruption and buckling of parts can be caused by over-firing of your fireplace. Over- firing above the rated value specified in the manual is contrary to the manufacturer's instructions and may void this warranty. • All installations must be performed by a qualified technician in accordance with applicable local and national requirements. • Installations must be done in accordance with the Flare Fireplaces installation manual.The Limited Warranty applies only if the product is installed in the United States or Canada and only if installed, operated, and maintained in accordance with the attached product manual. • It is the responsibility of the installer to ensure the appliance is firing per the rating plate. • Any part that is found in our judgment to be defective shall be repaired, replaced,or refunded at Flare Fireplaces' option. • This warranty only covers appliances that are purchased through a Flare Fireplaces authorized dealer or distributor. • The warranty is only valid while the appliance remains at the site of original installation. • Flare Fireplaces does not install or provide installation services.The installation of the fireplaces must be done by authorized installer.The fireplace limited warranty does not cover the installation service,or any part related to the installation of the fireplace or surrounding of the fireplace and venting. • Contact your dealer for warranty service. If the dealer is unable to provide necessary parts,contact the nearest Flare Fireplaces authorized dealer or supplier. EXCLUSIONS • This warranty does not apply to any component that shows evidence of misuse, abuse, improper installation, accident, or lack of maintenance. • Flare Fireplaces is not responsible for televisions, mantels,surrounds or finishing material around the fireplace. • Flare Fireplaces is not responsible for installation,operational or environmental conditions beyond our control. • Flare Fireplaces shall in no event be liable for any special, indirect, or consequential damages of any nature which are more than the original purchase price of the product. • Flare Fireplaces may at its discretion discharge all obligations by refunding the wholesale price of the defective part. • This warranty may not be extended or modified by our dealers or representatives. • The Limited Warranty only covers parts and labor as provided above. Flare Fireplaces will not be responsible for materials, components, or construction, which are not manufactured or supplied by Flare Fireplaces or for the labor necessary to install, repair or remove such materials, components, or construction. WARRANTY VOIDED WHEN • An unauthorized media type is used in the firebox. • The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine,or other damaging chemicals.Over-firing can be identified by, but not limited to,warped plates or pipes, rust colored iron or bubbling, cracking and discoloration of steel or enamel finishes. • The appliance is subjected to prolonged periods of moisture or condensation. • There is any damage to the appliance or other components due to water or weather damage,which is the result of, but not limited to, improper chimney or venting installation. • Holes have been drilled into the fireplace for any reason. RECEIVED ( 04/10/2023 107 ( Page ASPEN BUILDING DEPARTMENT