HomeMy WebLinkAboutFile Documents.315 E Hyman Ave.0011-2023-BCOM (31) 11)1.1 IvaI IL
THE CITY OF ASPEN City of Aspen and Pitkin County
FIREPLACE & WOODSTOVE REGISTRATION
*Parcel Id number: -- -- --
Street Address: 315 East Hyman Ave, Aspen CO 81612
Owners Name: Gravity Haus
*Required—Contact Assessors offices at 920-5160
Registration will not be accepted without a Parcel Id number
List all devices in your home (2 are allowed per building, except for gas appliances)
Note:If the number, type and location on this registration form do not match what is show on your plans or what is actually
installed,your permit or Certificate of Occupancy will be denied.
Type of Building (circle one): Residential Other
Type of device Room Existing New Make & Model
Wood burning fireplace (select one)
?Site-built masonry
?Factory built insert: model
number:
Gas log fireplace (select one)
?Site-built masonry
?Factory built insert: model
number:
Certified woodstove
Gas fireplace appliance
(attach spec sheet) Restaurant 201-1 & 202-1 2 Flare FF-70H & FF-30H
If any devices are being removed, please describe here, i.e. "old woodstove removed from living room"
.4.717/7 03-20-2023
Signature of applicant Date RECEIVED
G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc 0 4/10/2 0 2 3
over
ASPEN
BUILDING DEPARTMENT
ASPEN/PITKIN COUNTY FIREPLACE AND WOODSTOVE REGULATIONS
In order to keep our air as clean as possible,the elected officials of Aspen and Pitkin County have passed ordinances to regulate the
number of fireplaces and woodstoves that can be installed in any building. Building permit applicants must file a
fireplace/woodstove registration with the City of Aspen Building Department or the Pitkin County Building Department before the
building permit is issued.
Pitkin County is separated into 2 areas. One is the non attainment area,which includes the City of Aspen and the Metropolitan
areas of the county,i.e.Mountain Valley,Red Mountain,Difficult Campground,T Lazy 7 Ranch,and part of Starwood. The other
is the attainment area which includes the less densely populated parts of the county,i.e.Brush Creek Village,Holland Hills and
Old Snowmass.
Decorative gas appliance:A device utilizing natural gas as a fuel gas designed to appear as a real fireplace with a 4 to 5 inch Class
B vent or direct vent,fixed glass door and a firebox no deeper than 24 inches.
Certified Woodstove: Colorado Phase III certified woodstove or a Phase II EPA certified woodstove.
Gas log fireplace:Meet all codes for burning wood but are used with gas logs. They are not allowed in bedrooms.
Aspen and Metropolitan Areas of Pitkin County in the non attainment area
New buildings in the non attainment area may have either 2 gas log fireplace or 2 certified woodstoves or 1 each. They may also
have an unlimited number of decorative gas appliances. Wood burning fireplaces cannot be installed,nor may coal be used as fuel.
Remodeling or an addition to an existing home in the non attainment area
• If the building has 2 or more fireplaces,gas log fireplaces or woodstoves,they only devices you can add are decorative gas
appliances.
• If the building has 1 fireplace,gas log fireplace or woodstove,you may add 1 gas log fireplace and an unlimited number of
decorative gas appliances.
• If a building has more than 2 fireplaces,gas log fireplaces;if one is affected by the remodel it must be removed.
• If a building has only 1 or 2 fireplaces,woodstoves or gas log fireplaces,please keep in mind:
o If you alter the firebox of a fireplace,it must be converted to gas logs or removed.
o If a woodstove is moved,it must be removed or replaced with a department certified woodstove.
Attainment Area in Pitkin County
New residential buildings in this area may have one wood burning fireplace and one gas log or certified woodstove. If there is no
fireplace,you may have either 2 gas log fireplaces or 2 certified woodstoves or 1 each. Buildings may also have an unlimited
number of decorative gas appliances.
Remodeling or an addition to an existing building in the attainment areas
• If the building has 2 or more fireplaces or woodstoves,the only devices you can add are decorative gas appliances.
• If you have 1 fireplace or woodstove,you may add 1 gas log or certified woodstove and an unlimited number of decorative
gas appliances
• If a building has more than 2 fireplaces or woodstoves: if one is affected by a remodel,it must be removed
• If a building has on 1 or 2 fireplaces,woodstoves or gas log appliances,please keep in mind:
o If a woodstove is moved,it must be removed or replaced with a department certified device.
o If you alter the firebox of a fireplace,and already have another fireplace,it must be converted to gas log
Non residential buildngs(which include commercial buildings,restaurants,lodges,public buildings,and hotels)in the attainment
area of Pitkin County are allowed to have gas appliances.
RECEIVED
G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc 0 4/10/2 0 2 3
over
ASPEN
BUILDING DEPARTMENT
FLARE
`) FI REPLACES
SECTION 10 31 00
MANUFACTURED FIREPLACES
PART 1 - GENERAL
1.1 SECTION INCLUDES
A. Flare FF-30-H: Manufactured indoor gas direct vent fireplaces and accessories.
1.2 RELATED SECTIONS
A. Section 26 05 00 - Common Work Results for Electrical.
B. Refer to Mechanical and Electrical Specifications and Drawings for related information on air, gas,
flue, venting and electrical requirements.
1.3 CERTIFICATION REFERENCES
A. ANSI Z21.88—CSA 2.33 Vented Gas Fireplace Heater
B. CLASS 2901 04— DOMESTIC HEATERS (GAS) —Vented Fireplace (2901-04, 2901-84)
1.4 DESIGN / PERFORMANCE REQUIREMENTS
A. Comply with ANSI Z21.88/CSA 2.33a and gas-fired appliances for use at high altitudes CAN/CGA
2.17-M91/
B. Appliances are CSA marked as Certified to US Standard CLASS 2901 04 - DOMESTIC HEATERS (GAS)
Vented Fireplace (2901-04, 2901-84)
C. Direct Vent appliances shall be electrically grounded in accordance with the local codes or, in the
absence of local codes, with National Electric code, ANSI/NFPA 70, or the Canadian Electric Code,
CSA C22.1 as applicable.
1.5 SUBMITTALS
A. Submit under provisions of Section 01 33 00.
B. Product Data: Manufacturer's data sheets on each product to be used, including:
1. Preparation instructions and recommendations.
2. Storage and handling requirements and recommendations.
3. Installation methods.
C. Shop Drawings: Provide drawing of required clearances, rough-in of enclosure and utilities.
1.6 PRE-INSTALLATION MEETINGS
A. Convene a minimum two weeks prior to starting work of this section. RECEIVED
B. Installation must be handled by a certified fireplace technician, or trained dealer rep ree4 0/2023
ASPEN
BUILDING DEPARTMENT
1.7 DELIVERY, STORAGE, AND HANDLING
A. Deliver and store products in manufacturer's unopened packaging bearing the brand name and
manufacturer's identification until ready for installation.
B. Handling: Handle materials to avoid damage.
1.8 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits
recommended by manufacturer for optimum results. Do not install products under environmental
conditions outside manufacturer's recommended limits.
1.9 SEQUENCING
A. Ensure that products of this section are supplied to affected trades in time to prevent interruption
of construction progress.
1.10 WARRANTY
A. Provide the manufacturer's product body and firebox 10 Year Limited Warranty and the ceramic
glass 5 Year limited warranty against thermal breakage.
1. Flare Fireplaces Warranty Policy
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Flare Fireplaces LLC . - 890 N Dorothy Dr Suite 900, Richardson, TX 75081
Email: info@flarefireplaces.com Phone: 1 (866) 639-1590
B. Alternate Manufacturer: Not permitted.
2.2 MANUFACTURED INDOOR GAS FIREPLACES
A. Flare FF-30-H
1. Glass Viewing Area Flare-FF-30-H W 28 4/16 inches x H 24 inches
2. Maximum Heat Output (BTU) NG: 34000
3. Maximum Heat Output (BTU) LP: 23000
4. Efficiency: 80 percent efficient
5. Vent: Use Simpson Dura-Vent (4x6 and 5x8 Catalog I 3x5 Catalog) or ICC double-wall vent
system only.
a. Direct Vent: 46DVA.
b. Power Vent System: 35CVS.
c. Vertical or Horizontal direct vent termination.
6. Glass:
a. Single pane ceramic glass with screen barrier.
b. Double pane with inner ceramic and outer tempered glass, equipped with•'qu et f fn; 1 cr
assistance. *Requires air intake below the firebox.
04/10/2023
ASPEN
BUILDING DEPARTMENT
7. Decorative Media:
a. Ceramic Stones: [White] [Black] [Earth]
b. Ceramic Pebbles: [White] [Black] [Gray]
c. Driftwood Logs: [Small] [Large]
d. Fire Glass: [Silver] [Clear] [Black] [Bronze] [Gold] [Chestnut] [Black Diamond] [Raindrop]
e. Ceramic Logs
f. Ceramic Branches
g. Birchwood
h. Stone Balls: [White] [Black] [Gray]
8. Interiors:
a. Standard matte black interior finish.
b. Reflective Back: Neo-ceramic black reflective glass.
9. Controls: On/Off, thermostatic mode, child safety, and flame height operation.
a. Wall Switch (Included)
b. Timer (Optional)
c. Remote Control (Included)
d. Home Automation Integration (Optional)
10. Optional Accessories:
a. Flare Inline Power Vent System with DuraVent 35CVS. (*Optional, based on unique vent
run requirements)
b. Flare End-of-Line Horizontal Power Vent System with DuraVent 35CVS. (*Optional,
based on unique vent run requirements)
c. Flare End-of-Line Vertical Power Vent System with DuraVent 35CVS. (*Optional, based
on unique vent run requirements)
d. Flare End-of-Line Summer Kit
e. Flare Inline Summer Kit
f. Flare RGB LED Lighting
g. Flare Outdoor Kit
E. Provide other materials, not specifically described but required for a complete and proper
installation, as selected by Contractor, subject to Architect's approval.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Do not begin installation until substrates have been properly prepared.
B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory
preparation before proceeding.
3.2 PREPARATION
A. Clean surfaces thoroughly prior to installation.
B. Prepare surfaces using the methods recommended by the manufacturer for achievin ; 1e abet j�,,�i r=
result for the substrate under the project conditions.
04/10/2023
ASPEN
BUILDING DEPARTMENT
C. Prepare fireplace installation location with noncombustible materials only. Use clearances
information from the installation manual.
D. Confirm vent path and vent termination location.
3.3 INSTALLATION
A. Install in accordance with manufacturer's instructions, ANSI Z21.88—CSA 2.33
B. Use manufacturer's guidelines for minimum clearances to combustibles, walls, and finishes.
C. Confirm heat release size and location based on installation manual. Confirm air intake location and
size if using the Double Glass option.
D. Anchor all components firmly in position for long life under hard use.
3.4 FIELD QUALITY CONTROL
A. Upon completion of installation, visually inspect all exposed surfaces. Touch up scratches and
abrasions with touch-up paint recommended by the manufacturer, make imperfections invisible to
the unaided eye from 5 feet.
B. Test for proper operation, control, and safety devices.
C. Complete Installer's Warranty Validation Card.
3.5 PROTECTION
A. Protect installed products until completion of project.
B. Touch-up, repair or replace damaged products before Substantial Completion.
END OF SECTION
RECEIVED
04/10/2023
ASPEN
BUILDING DEPARTMENT
,8FLARE
FIREPLACES PRODUCT SHEET: FLARE-FF-30-H
DIRECT VENT FLARE-FF-30-H
FLARE FRAMELESS MODERN FRONT FACING FIREPLACE
SKU: DVFF3OH
Item Details
Gas Type Options Natural Gas (NG) or Liquid Propane (LP)
Safety Standards CSA File # 263124 -ANSI Z21.88 - CSA 2.33
Gas Valve System SIT Proflame II
Electrical 110 Volts, 15 Amps (Dedicated Circuit Recommended)
Glass Height 24"
Safety Barrier Safety Screen (Standard Barrier) - SS Double Glass (Optional Upgrade) - DG
In Crate No Crate
Weights 311 lbs. (SS) 330 lbs. (DG) 287 lbs. (SS) 298 lbs. (DG)
Included Features Power Supply, Wall Switch, Remote, Option of Classic Media
Cool Wall Tech Allows television or art piece 12" above fireplace opening
Burner Advanced 3D Multi-Row Burner System
Double Glass Reflective Back Summer Kits
Optional Features Features Page
RGB LEDs Reflective Sides Power Vents
Interior Media Flare Fireplace Media Options
PRODUCT SPECIFICATIONS
• The Flare Fireplace is certified for use with either Natural Gas (NG) or Propane (LP)
• The Flare Fireplace operates with a direct vent, balanced flue system. A direct vent gas fireplace is room-
sealed using ceramic glass.
• The Flare Fireplace use's double pipe vent flue to pull in fresh air from outside & release exhaust gases to the
outside. Clearances to combustible materials MUST be maintained. Refer to Installation Manual for clearance
distances.
• The Flare Fireplace must be properly connected to a venting system.
• The Flare Fireplace must be installed according to requirements as presented in the Installation Manual, as
well as complying with all local codes. If no codes exist, then the current CSA installation code must be followed.
RECEIVED
04/10/2023
ASPEN
BUILDING DEPARTMENT
F LARE
FIREPLACES
PARTS INCLUDED: OPTIONAL FEATURES:
• Flare Fireplace • Double Glass Safety Barrier
• Ceramic Glass Panel(s) • Reflective Black Ceramic Glass Back & Sides
• Invisible Mesh Safety Screen • Summer Kit Heat Control System
• Option of "Classic" Media • Home Automation (3rd Party Support Only)
• Complete Electronic Ignition Pilot • Battery Backup (Screen Units Only)
• Spare Parts Kit
• Telescopic Legs & Mounting Brackets APPROVED VENTING:
• AC Power Supply, Remote, & Wall Switch • DuraVent
• ICC
• Natural Draft Pipe Size: 4x6
• Power Vented Pipe Size: 3x5
GAS PRESSURE& POWER OUTPUT NG EFFICIENCY 79% I LP EFFICIENCY 81%
SIT
GAS INLET PRESSURE MANIFOLD MAX BTU ORIFICE SIZE BURNER SIZE
TYPE MIN MAX PRESSURE INPUT LEFT CENTER RIGHT LEFT CENTER RIGHT
BURNER BURNER BURNER BURNER BURNER BURNER
NG 7.0"WC 8.0"WC 3.5"WC 34,000 0 1000 0
LP 10.0"WC 11.0"WC 9.5"WC 23,000 0 260 0 0 22" 0
HONEYWELL(LEGACY)
INLET PRESSURE ORIFICE SIZE BURNER SIZE
GAS MANIFOLD MAX BTU LEFT CENTER RIGHT LEFT CENTER RIGHT
TYPE MIN MAX PRESSURE INPUT BURNER BURNER BURNER BURNER BURNER BURNER
NG 7.0"WC 8.0"WC 4.0"WC 34,000 0 800 0
LP 10.0"WC 11.0"WC 10.0"WC 26,200 0 260 0 0 22" 0
GV60(LEGACY)
INLET PRESSURE ORIFICE SIZE BURNER SIZE
GAS MANIFOLD MAX BTU LEFT CENTER RIGHT LEFT CENTER RIGHT
TYPE MIN MAX PRESSURE INPUT BURNER BURNER BURNER BURNER BURNER BURNER
NG 7.0"WC 8.0"WC 6.4"WC 34,000 0 800 0
LP 10.0"WC 11.0"WC 10.6"WC 26,200 0 260 0 0 22" 0
For more information on Flare, or our amazing features, please visit: https://www.flarefireplaces.com
RECEIVED
04/10/2023
ASPEN
BUILDING DEPARTMENT
FLARE
`) FI REPLACES
SECTION 10 31 00
MANUFACTURED FIREPLACES
PART 1 - GENERAL
1.1 SECTION INCLUDES
A. Flare FF-70-H: Manufactured indoor gas direct vent fireplaces and accessories.
1.2 RELATED SECTIONS
A. Section 26 05 00 - Common Work Results for Electrical.
B. Refer to Mechanical and Electrical Specifications and Drawings for related information on air, gas,
flue, venting and electrical requirements.
1.3 CERTIFICATION REFERENCES
A. ANSI Z21.88—CSA 2.33 Vented Gas Fireplace Heater
B. CLASS 2901 04— DOMESTIC HEATERS (GAS) —Vented Fireplace (2901-04, 2901-84)
1.4 DESIGN / PERFORMANCE REQUIREMENTS
A. Comply with ANSI Z21.88/CSA 2.33a and gas-fired appliances for use at high altitudes CAN/CGA
2.17-M91/
B. Appliances are CSA marked as Certified to US Standard CLASS 2901 04 - DOMESTIC HEATERS (GAS)
Vented Fireplace (2901-04, 2901-84)
C. Direct Vent appliances shall be electrically grounded in accordance with the local codes or, in the
absence of local codes, with National Electric code, ANSI/NFPA 70, or the Canadian Electric Code,
CSA C22.1 as applicable.
1.5 SUBMITTALS
A. Submit under provisions of Section 01 33 00.
B. Product Data: Manufacturer's data sheets on each product to be used, including:
1. Preparation instructions and recommendations.
2. Storage and handling requirements and recommendations.
3. Installation methods.
C. Shop Drawings: Provide drawing of required clearances, rough-in of enclosure and utilities.
1.6 PRE-INSTALLATION MEETINGS
A. Convene a minimum two weeks prior to starting work of this section. RECEIVED
B. Installation must be handled by a certified fireplace technician, or trained dealer repreM11110/2023
ASPEN
BUILDING DEPARTMENT
1.7 DELIVERY, STORAGE, AND HANDLING
A. Deliver and store products in manufacturer's unopened packaging bearing the brand name and
manufacturer's identification until ready for installation.
B. Handling: Handle materials to avoid damage.
1.8 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits
recommended by manufacturer for optimum results. Do not install products under environmental
conditions outside manufacturer's recommended limits.
1.9 SEQUENCING
A. Ensure that products of this section are supplied to affected trades in time to prevent interruption
of construction progress.
1.10 WARRANTY
A. Provide the manufacturer's product body and firebox 10 Year Limited Warranty and the ceramic
glass 5 Year limited warranty against thermal breakage.
1. Flare Fireplaces Warranty Policy
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Flare Fireplaces LLC . - 890 N Dorothy Dr Suite 900, Richardson, TX 75081
Email: info@flarefireplaces.com Phone: 1 (866) 639-1590
B. Alternate Manufacturer: Not permitted.
2.2 MANUFACTURED INDOOR GAS FIREPLACES
A. Flare FF-70-H
1. Glass Viewing Area Flare-FF-70-H W 67 10/16 inches x H 24 inches
2. Maximum Heat Output (BTU) NG: 52000
3. Maximum Heat Output (BTU) LP: 45000
4. Efficiency: 78 percent efficient
5. Vent: Use Simpson Dura-Vent (4x6 and 5x8 Catalog I 3x5 Catalog) or ICC double-wall vent
system only.
a. Direct Vent: 58DVA.
b. Power Vent System: 35CVS.
c. Vertical or Horizontal direct vent termination.
6. Glass:
a. Single pane ceramic glass with screen barrier.
b. Double pane with inner ceramic and outer tempered glass, equipped with•'qu et f fn; 1 cr
assistance. *Requires air intake below the firebox.
04/10/2023
ASPEN
BUILDING DEPARTMENT
7. Decorative Media:
a. Ceramic Stones: [White] [Black] [Earth]
b. Ceramic Pebbles: [White] [Black] [Gray]
c. Driftwood Logs: [Small] [Large]
d. Fire Glass: [Silver] [Clear] [Black] [Bronze] [Gold] [Chestnut] [Black Diamond] [Raindrop]
e. Ceramic Logs
f. Ceramic Branches
g. Birchwood
h. Stone Balls: [White] [Black] [Gray]
8. Interiors:
a. Standard matte black interior finish.
b. Reflective Back: Neo-ceramic black reflective glass.
9. Controls: On/Off, thermostatic mode, child safety, and flame height operation.
a. Wall Switch (Included)
b. Timer (Optional)
c. Remote Control (Included)
d. Home Automation Integration (Optional)
10. Optional Accessories:
a. Flare Inline Power Vent System with DuraVent 35CVS. (*Optional, based on unique vent
run requirements)
b. Flare End-of-Line Horizontal Power Vent System with DuraVent 35CVS. (*Optional,
based on unique vent run requirements)
c. Flare End-of-Line Vertical Power Vent System with DuraVent 35CVS. (*Optional, based
on unique vent run requirements)
d. Flare End-of-Line Summer Kit
e. Flare Inline Summer Kit
f. Flare RGB LED Lighting
g. Flare Outdoor Kit
E. Provide other materials, not specifically described but required for a complete and proper
installation, as selected by Contractor, subject to Architect's approval.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Do not begin installation until substrates have been properly prepared.
B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory
preparation before proceeding.
3.2 PREPARATION
A. Clean surfaces thoroughly prior to installation.
B. Prepare surfaces using the methods recommended by the manufacturer for achievin ; 1e abet j�,,�i r=
result for the substrate under the project conditions.
04/10/2023
ASPEN
BUILDING DEPARTMENT
C. Prepare fireplace installation location with noncombustible materials only. Use clearances
information from the installation manual.
D. Confirm vent path and vent termination location.
3.3 INSTALLATION
A. Install in accordance with manufacturer's instructions, ANSI Z21.88—CSA 2.33
B. Use manufacturer's guidelines for minimum clearances to combustibles, walls, and finishes.
C. Confirm heat release size and location based on installation manual. Confirm air intake location and
size if using the Double Glass option.
D. Anchor all components firmly in position for long life under hard use.
3.4 FIELD QUALITY CONTROL
A. Upon completion of installation, visually inspect all exposed surfaces. Touch up scratches and
abrasions with touch-up paint recommended by the manufacturer, make imperfections invisible to
the unaided eye from 5 feet.
B. Test for proper operation, control, and safety devices.
C. Complete Installer's Warranty Validation Card.
3.5 PROTECTION
A. Protect installed products until completion of project.
B. Touch-up, repair or replace damaged products before Substantial Completion.
END OF SECTION
RECEIVED
04/10/2023
ASPEN
BUILDING DEPARTMENT
,8FLARE
FIREPLACES PRODUCT SHEET: FLARE-FF-70-H
DIRECT VENT FLARE-FF-70-H
FLARE FRAMELESS MODERN FRONT FACING FIREPLACE
SKU: DVFF7OH
Item Details
Gas Type Options Natural Gas (NG) or Liquid Propane (LP)
Safety Standards CSA File #263124 -ANSI Z21.88 - CSA 2.33
Gas Valve System SIT Proflame II
Electrical 110 Volts, 15 Amps (Dedicated Circuit Recommended)
Glass Height 24"
Safety Barrier Safety Screen (Standard Barrier) - SS Double Glass (Optional Upgrade) - DG
In Crate No Crate
Weights 467 lbs. (SS) 511 lbs. (DG) 423 lbs. (SS) 445 lbs. (DG)
Included Features Power Supply, Wall Switch, Remote, Option of Classic Media
Cool Wall Tech Allows television or art piece 12" above fireplace opening
Burner Advanced 3D Multi-Row Burner System
Double Glass Reflective Back Summer Kits
Optional Features Features Page
RGB LEDs Reflective Sides Power Vents
Interior Media Flare Fireplace Media Options
PRODUCT SPECIFICATIONS
• The Flare Fireplace is certified for use with either Natural Gas (NG) or Propane (LP)
• The Flare Fireplace operates with a direct vent, balanced flue system. A direct vent gas fireplace is room-
sealed using ceramic glass.
• The Flare Fireplace use's double pipe vent flue to pull in fresh air from outside & release exhaust gases to the
outside. Clearances to combustible materials MUST be maintained. Refer to Installation Manual for clearance
distances.
• The Flare Fireplace must be properly connected to a venting system.
• The Flare Fireplace must be installed according to requirements as presented in the Installation Manual, as
well as complying with all local codes. If no codes exist, then the current CSA installation code must be followed.
RECEIVED
04/10/2023
ASPEN
BUILDING DEPARTMENT
FLARE
`� FIREPLACES
PARTS INCLUDED: OPTIONAL FEATURES:
• Flare Fireplace • Double Glass Safety Barrier
• Ceramic Glass Panel(s) • Reflective Black Ceramic Glass Back & Sides
• Invisible Mesh Safety Screen • Summer Kit Heat Control System
• Option of "Classic" Media • Home Automation (3rd Party Support Only)
• Complete Electronic Ignition Pilot • Battery Backup (Screen Units Only)
• Spare Parts Kit
• Telescopic Legs & Mounting Brackets APPROVED VENTING:
• AC Power Supply, Remote, & Wall Switch • DuraVent
• ICC
• Natural Draft Pipe Size: 5x8
• Power Vented Pipe Size: 3x5
GAS PRESSURE&POWER OUTPUT NG EFFICIENCY 82% 1 LP EFFICIENCY 79%
SIT
INLET PRESSURE ORIFICE SIZE BURNER SIZE
GAS MANIFOLD MAX BTU
TYPE MIN MAX PRESSURE INPUT LEFT CENTER RIGHT LEFT CENTER RIGHT
BURNER BURNER BURNER BURNER BURNER BURNER
NG 7.0"WC 8.0"WC 3.5"WC 52,200 420 900 420
14" 32" 14"
LP 10.0" WC 11.0"WC 9.5"WC 45,000 140 260 140
HONEYWELL(LEGACY)
GAS INLET PRESSURE MANIFOLD MAX BTU ORIFICE SIZE BURNER SIZE
TYPE MIN MAX PRESSURE INPUT LEFT CENTER RIGHT LEFT CENTER RIGHT
BURNER BURNER BURNER BURNER BURNER BURNER
NG 7.0"WC 8.0"WC 2.7"WC 52,200 480 1000 480
LP 10.0" WC 11.0"WC 6.3"WC 43,000 160 320 160 14" 32" 14"
GV60(LEGACY)
INLET PRESSURE ORIFICE SIZE BURNER SIZE
GAS MANIFOLD MAX BTU
TYPE MIN MAX PRESSURE INPUT LEFT CENTER RIGHT LEFT CENTER RIGHT
BURNER BURNER BURNER BURNER BURNER BURNER
NG 7.0"WC 8.0"WC 3.2"WC 52,200 480 1000 480
LP 10.0" WC 11.0"WC 6.7"WC 43,000 160 320 160 14" 32" 14"
For more information on Flare, or our amazing features, please visit: https://www.flarefireplaces.com
RECEIVED
04/10/2023
ASPEN