Loading...
HomeMy WebLinkAboutFile Documents.485 Rio Grande Pl.0024-2024-BREP (5) APPLICATION ACCEPTED DATE: 2024-0.4 PERMIT NUMBER: 0024-2020-BREP Field Plan Set Must Be Printed In Color �►I COMMUNITY DEVELOPMENT DEPARTMENT 1` ',� ;`'p'/ BUILDING PERMIT COVERSHEET `��� CITY.OF ASPEN d'►F CITY OF ASPEN I PROPERTY INFORMATION ADDRESS: 085 RIO GRANDE PL UNIT: PERMIT NO.0024-2024-BREP CITY OF PARCEL ID: 273707347851 REGAL DESCRIPTION: NTRIN COUNTY CEN, ASPEN PITON COUNTY OWNER PITKIN COUNTY ASPEN PERMIT CONTRACTOR: ADDRESS 485 RIO GRANDE PL These plans muus e.M pt at the DESCRIPTOR OF WORK Break up aHaul away 60'long concr wide a5'deep sectbndNoor in hallway PARCEL ID 273707347851 building site or inspection Haulaway din and concrete delays may occur.Construction Remove and replace 180)eig5ty feet of O.cast iron pipe and replace wall 4"PVCELYP shall conform to these plans.All Provide and installdeal000 for future service changes shall be approved by Provide and instal16"of gravel below piping Ing official. (MORN remaining trench with gravel Papaw concrete Televise measure proper Installation SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING,MECHANICAL,OR USE OF BUILDING Mixed-Use FIRE SPRINKLER REQUIRED? FIRE SPRINKLER WORK CLASS OF WORK Commercial FIRE SPRINKLER TYPE SMOKE ALARMS AND CARBON MONOXIDE BUILDING TYPE INC) REQUIRED SPECIAL REQUIRED INSPECTIONS THROUGHOUT DWELLING UNIT PER CITY OF ASPEN CONSTRUCTION TYPE Ina ENERGY CODE COMPLIANCE Prescriptive Table MUNICIPAL CODE 8.15 OCCUPANCY GROUP DMF3 WORK CHANGES BUILDING FOOTPRINT? CODE EDITIONS 2021 I8C TOTAL SPA SQ.FT. I It should be known that this review shall not relieve the applicant of their OTHER CODE EDITIONS TOTAL SNOWMELT MST. responsibility to comply with the requirements of the City of Aspen I HISTORIC PROPERTY? No TOTAL POOL SIFT. Municipal Code.Pursuant to Sec.26.104.050,any permit or approval issued in error or otherwise not in FIRE SPRINKLER EXISTING, conformity with the requirements of this Title,shall be void.Similarly,any permit or approval issued in reliance upon or as a result of,a materially false statement or representation made in the process of obtaining the permit or development approval shall,likewise, A FilMiligirilio `C f�� �_ of5 pF�vM•� / be void. o person orang ppiovaa (. void or voidable permitavi or approval shall not be relieved from having to � rl• 5o4 E. MA.10 S, • comply with all applicable terms and t`t tt conditions of this Title and the City shall D V not be estopped from fully enforcing / - S Ase same. 0J ~'\ t I'r.►'no°�' I - riliEWIE�t/WIMMEI E��11■ tea„Ir04/2024 Di i �� I je LVr _ awCQ z I14 ill 0.1" s6L • 1 /4.7d, E a•� ortsz- 1 _.> Lim e. Psi PLUMBING SYSTEMS INC. Master License 185796 t S ( 5w•� T • _ PO Box 4160,Gypsum,Colorado 8als III 13 r r- A�A � -�!+ F �� 970.926.0500 Office to.xA 4 Or w S ill") t ____..s uu TIBG I,oR ��� t I - Narrative Date: August 30,2024 Jo .". Client/Owner: Pitkin County Jail 'IC Project Address: 485 Rio Grande PI 0 Aspen,CO 81611 Problem: • Sewer pipe has a singular large low spot where multiple lines from the jail cell toilets tie into causing backups. Steps to Fix It: • • Break up a 60'long x 2.5'wide x 5'deep section of floor in hallway • Haul away dirt and concrete • Remove and replace(80)eighty feet of 4"cast iron pipe and replace with 4"PVC pipe • Provide and install cleanouts for future service • Provide and install 6"of gravel below piping • Backfill remaining trench with gravel • Repour concrete • Televise to ensure proper installation