Loading...
HomeMy WebLinkAboutFile Documents.1315 Sage Ct.0082-2021-BRES (5) 0082-2021 -BRES_ZoningComments_1 90.Architectural Plans.20210506.pdf(23) Subject:Text Box Page: 5 Only new roof will need height Page Index: 5 measurements, and will need to Author: haleyhbe re-measured for roof pitch Fofwneedhoight Color: ■ since there are two separate uredforroofpitches. See A404 for details. ches.SeeA40 File Name: 90.Architectural Plans.20210506.pdf L'f THIS HAS BEEN UPDATED. ID''''U�6�G6 i®]]6 fib' I111I �-, - Subject: Highlight Page: 5 Page Index: 5 Author: haleyh D.USGS 7776.68' Color: T.O.PLY @ 1/3 point File Name: 90.Architectural Plans.20210506.pdf I /I - Subject: Cloud+ What is the FA for this deck? 0 Page: 6 o �" " Page Index: 6 1 17 Author: haleyh MY MISTAKE -THIS IS Color: ■ FOR THE PROPOSED -- �,rAa File Name: 90.Architectural Plans.20210506.pdf AREA PLAN AND THE 17-''`Mvw."1 A102 EXISTING PLAN IS UPDATED. Subject: Cloud+ I think am getting confused by Page: 6 your legend and labeling. This Page Index: 6 _ t calculation seems to be adding Author: haleyh Color: • together the back patio and the File Name: 90.Architectural Plans.20210506.pdf front porch.Your back patio seems to be below 6"and the 1 — front porch is exempt-therefore, °eELtiWt neither of these would be deck. 'l ` But the symbolism looks like its the same as the deck in the garage. Please clarify what is patio,what is front porch,what is deck, and what is exempt. I dont believe you will count anything towards deck because it is less than 912.81, but if you could clarify that would be helpful on my end. I HAVE CHANGED THE EXEMPT AREA HATCH TO BE TRIANGLES. THE TABLE HAS BEEN UPDATED TO REMOVE THE EXEMPT AREAS THAT ARE WITHIN 6" OF GRADE AND THAT ARE A FRONT PORCH FOR CLARITY. RECEI EP 11/30/2021 ASPEN BUILDING DEPARTMENT Subject: Cloud+ Page: 6 Allowable FA is: 6,085.43 and Page Index: 6 Allowable Deck is 912.81 per Z100-your calculations here are m Author: haleyh Color: • based off of gross lot size, not File Name: 90.Architectural Plans.20210506.pdf net lot size (it should be on net lot size). .m, This was correct on the Proposed FA sheet and I forgot to carry over-the existing table has been updated. Subject: Cloud+ ®® µ Page: 6 Looks like there might be deck to Page Index: 6 the right of the guest bed area in Author: haleyh your drawing? y 3 Color: ■ that is accidentally showing on the existing File Name: 90.Architectural Plans.20210506.pdf_-w - p plans. This has been updated on the plans. Subject: Cloud+ Please update with corrected Vim_ - -R Page: 6 lower level calculations and deck Page Index: 6 Author: haleyh at the garage structure. -- Color: • File Name: 90.Architectural Plans.20210506.pdf This has been updated. ® _ Subject: Cloud+ —1�- --. - o This should be counted as one oaa� Page: 6 Page Index: 6 structure for sub-grade walls: ie: Author: haleyh show subgrade walls as four Color: • walls as it looks like the garage, File Name: 90.Architectural Plans.20210506.pdf mech, guest bed and guest bath o% , all have subgrade walls. This has been updated. Subject: Cloud+ Page: 6 This is calculated as: gross Page Index: 6 square footage of entire structure,then subtract out the Author: haleyh Color: • garage exemption (375 sf), then . File Name: 90.Architectural Plans.20210506.pdf multiply remaining number by subgrade wall percentage. Please Pl revise. This has been updated. RECEIVED 11/30/2021 ASPEN BUILDING DEPARTMENT - z '1 -_= ' -- ' Subject: Cloud+ _ -m __.�0 Page: 6 Why is this 0? 18.69+the area ""_ I = • Page Index: 6 to the right of the guest bed "--1 m i Author: haleyh area?Are you counting this as 0 ___ Color: ■ because the total is less than _a_,,, File Name: 90.Architectural Plans.20210506.pdf 912.81? Yes, the total floor area calculations for deck = 0.0 because it is less than the allowable for the site. Subject: Cloud+ w' Page: 7 This will count as deck. Please _, see note in Landscape Plans o;..--E°°�" _ ® Author: haleyh- -- % Page Index: 7 and revise in FA calculations. ©,o 0-1 �0 ° Color: ■ This is not pad of the structure of the deck 1 File Name: 90.Architectural Plans.20210506.pdf A� and has been lowered so doesn't count as c>.. deck anymore. Correspondence with Haley 0 0 ,� clarified the team's approach. Landscape and ii architectural FAR shows this update. Subject: Cloud+ .® Page: 7 Unsure of what this 14.48 sf of o �- deck is. Is this the existing deck Page Index: 7® r without a calculation on A102? t7MAuthor: haleyh Color: ■ This is a permanent outdoor o °R°°°sE°°° File Name: 90.Architectural Plans.20210506.pdf fireplace that is counted as floor FLOOR JMI A103 area. Subject: Cloud+ Page: 7 This chart has been cut off. Page Index: 7 1 1 t Author: haleyh This has been corrected. .-- - Color: • w °; I File Name: 90.Architectural Plans.20210506.pdf -;. IMr- - 11 I = eEow°�oEw.� Subject: Cloud+ Page: 7 1,052.36 or.66? ® Page Index: 7 Typo corrected. Author: haleyhP Floor Area Pro.m. Color: • ;c-- ,16.. ... File Name: 90.Architectural Plans.20210506.pdf m_d.. ,em Wiun. RECEIVED 11/30/2021 ASPEN BUILDING DEPARTMENT „� A1.@PM9.M Subject: Cloud+ ... �a; ` �”" Page: 7 Please break down deck FA in Page Index: 7 calculation sheet and match on ...� I .� 1 s -�°---,�m� drawings. I am getting 893.92 Author: haleyh �.p 1:s u Color: ■ File Name: 90.Architectural Plans.20210506.pdf a- ^sas3s, Yes that is the total between garage and house (14.58 + 879.35). See chart-This total is still under the allowable so 0 s.f. is counted towards allowable floor area. _ A..,-......e, Subject:Text Box —.. °��-,°,•,,— iiggiiiiiim Page: 7 Because this is cut off I cant Page Index: 7 quite tell what everything is. © Author: haleyh Please make sure you update Color: • your calculations/sub-grade ptlate your calculations/subgratle Talcs File Name: 90.Architectural Plans.20210506.pdf calcs etc ase on the existing deaea„oe FA advise. Please contact me if you need clarification prior to second submittal. .omw„ Charts are corrected to not be cut off. Subject: Cloud+ Page: 9 Demo is calculated by structure Page Index: 9 ie: please separate garage demo Author: haleyh calculations from the house. If i Color: • garage demo is over 40%will ® need to revise RDS approval for - File Name: 90.Architectural Plans.20210506.pdf 0 ~~ _ garage C.2 Garage Placement. �. =: a g: We can talk to Michelle. In the w. ^, 9 future if you are demoing a ` m Not applicable. structure you can just say that �_a"' and not have to show all drawings. Subject: Group Page: 32 Page Index: 32 Author: haleyh Color: ■ v 4 File Name: 90.Architectural Plans.20210506.pdf _ a s ' �.In „r iII m ='Mil Inc EIF ��9,N�NNiVI� — .. < r...... a e RECEIVED 11/30/2021 ASPEN BUILDING DEPARTMENT Subject: Cloud+ Page: 32 Point C? Could you please Page Index: 32 include all the Elevation Labels Author: haleyh on this page that correspond Color: • with Z101 in order to verify Q File Name: 90.Architectural Plans.20210506.pdf height and topography. lII. .111=3. jIlllllllluuu��� Labels to roof points added to i � elevations. Yes this is point C. Subject: Line _ Page: 32 Page Index: 32 EI.,YP.9 Author: haleyh 1l3 Pr BiWN EAVEN•B Color: ■ File Name: 90.Architectural Plans.20210506.pdf PROPOSED SNOW FENCES Subject:Text Box Page: 32 Combine both ridges-take Page Index: 32 combined roof -architect will Author: haleyh create new pitch-that is the Color: • pitch that will be used for all File Name: 90.Architectural Plans.20210506.pdf roofs that are combined together. 9 q (2)For properties in all other A line showing this combined pitch Zone Districts,the height of the has been added and the location of building shall be measured the elevation has been updated in according to the pitch of the roof plan and elevation. as follows. See Subsection (3), below,for measurement method.: For roofs with multiple pitches within one(1)vertical plane,the height of the roof shall be measured by drawing a line within a vertical section between the ridge and the Eave Point(s) and then applying the methodology for the resulting pitch of said line(s)as described above. Subject: 3/16"Scale Q Page: 35 25'-0" Page Index: 35 III ICI I II Author: haleyh • Color: • ■ou==. F File Name: 90.Architectural Plans.20210506.pdf .ER RECEIVED 11/30/2021 ASPEN BUILDING DEPARTMENT 90.Landscape Plans.20210506.pdf(2) _ ;., Subject: Cloud+ This planter will count as deck m Page: 2 �� %� = Page Index: 2 because it is less than 30"from .• ,- m Author: haleyh the deck surface. Or, you can Color: • increase the height. tv , File Name: 90.Landscape Plans.20210506.pdf Please see revised civil plans IaS�'' �' C600. m Please refer to emails dated ..„„ ': e _ 09.21.21 and 09.23.21 Subject: Cloud+ Page: 8 Because this planter is less than Page Index: 8 30"from deck surface,this will Author: haleyh count as deck FA. ® _M W Color: ■ Please see revised civil plans a. _,.o File Name: 90.Landscape Plans.20210506.pdf C600. Please refer to emails dated ,'.y "° :q®': 09.21.21 and 09.23.21 90.Mechanical Plans.20210506.pdf(2) ,E9SI Subject: Cloud+ 26.575.020.E.5 Allowed o��ia i�VI Page: [10]21032 SAGE CT MECH M1 2 ����. ,'.__ Page Index: 3 exceptions to setbacks: i, -ai •iiiii- & Author: haleyh n.Heating and air conditioning ® _ Color: • equipment and similar mechanical equipment shall File Name: 90.Mechanical Plans.20210506.pdf have the following These mechanical units have requirements:1.Prohibited been moved out of the setback. between any lot line adjacent to Refer to sheet M1-2 a street and any structure; and2.Shall be located at least double the minimum setback for a primary structure from any lot line adjacent to a street; and3.lf visible from the street,these features shall be screened in accordance with Section 26.575.050, Fences; and4.lf located within a setback not adjacent to a street,these features shall not exceed thirty (30)inches above or below finished grade. These features may be up to thirty(30)inches above and below finished grade simultaneously. RECEIVED 11/30/2021 ASPEN BUILDING DEPARTMENT Subject: Cloud+ Page: [10]21032-SAGE CT-MECH-M1-2 26.575.020.E.5 Allowed Page Index: 3 exceptions to setbacks: - Author: haleyh n.Heating and air conditioning _ Color: • equipment and similar --_ File Name: 90.Mechanical Plans.20210506.pdf mechanical equipment shall __ have the following 7 . -1 . _,,., requirements:1.Prohibited - ffl'j EllThese mechanical units have between any lot line adjacent to �% been moved out of the setback. a street and any structure; Refer to sheet M1-2 and2.Shall be located at least double the minimum setback for a primary structure from any lot line adjacent to a street; and3.lf visible from the street,these features shall be screened in accordance with Section 26.575.050, Fences; and4.lf located within a setback not adjacent to a street,these features shall not exceed thirty (30)inches above or below finished grade. These features may be up to thirty(30)inches above and below finished grade simultaneously. RECEIVED 11/30/2021 ASPEN BUILDING DEPARTMENT