Loading...
HomeMy WebLinkAboutFile Documents.616 E Hyman Ave.0035-2024-BCOM (5) NOBLE UNDERCOUNTER DISHMACHINES • 7 I 0 B E WAREWASHING INSTALLATION , OPERATION , AND SERVICE MANUAL `OBLE NOBLE U H30-FN D NOBLE UL30 en RECEIVED Noble UH30-FND/UL30 Manual •07610-004-37-38-P ►24 ASPEN BUILDING DEPARTMENT REVISION HISTORY Revision Date Made by Process Details A 7-18-16 JH N/A Initial release of the manual. B 3-7-17 JH N/A Added UL30 and UL3OH units. Updated pg.43 with new motor and assembly P/Ns. Updated water line connection information.Changed wording in the chemical feeder pump program- ming section to indicate changes are lost if closed without saving. Changed the steps in the Heater Contactor Wiring and Shutdown&Cleaning sections to be appli- C 5-17-17 JH 8511 cable to units with a mechanical timer.Removed item#25 from pg.48.Changed Discharge Hose to 05700-004-43-76 in the Wash Manifold Assembly. Added 05700-004-36-95 to UH3O-FND Display page and corrected the P/N for the Display Decal. Added a Plumbing Options page. D 6-6-17 JH N/A Corrected draining procedure.Corrected wash motor amps for UL30/UL3OH on Electrical Require- ments page.Updated the UL30/UL3OH schematic. Removed the UH3O-FND from the manual. E 8-23-17 JH QOF-386 Added the 100"chemical tubes for red,white,and blue to Chemical Feeder Pump Assembly page. F 10-17-17 JH N/A Added the UH3O-FND to the manual. Updated pg.2.Corrected references to flow pressure on pg.6. Updated references to E and G 2 19 19 JH 8585 F outputs on pgs.9-10.Corrected part numbers of motor assembly and motor only on pg.42. 8599 Updated parts on pg.44.Changed item#11 on pg.48. Updated item#6 on pg.52 and added link to instructions.Added links to instructions on pg.53. Revised Programming Chemical Feeder Pumps section. Updated chemical feeder pump assemblies. H 6-23-20 JH 8709 Updated plumbing for UL30. Revised UL30 and UL3OH control panel pages.Corrected drain hose 19-680 P/N. J 11-14-20 JH 8469 Revised drain line size. Updated dimensional drawing.Added mechanical timer instructions for UL30/ UL3OH. Updated timer P/N on pg.25. K 6-16-21 JH N/A Updated amp values of UL3OH.Changed P/N of high limit thermostat on UL3OH Optional Heater Components page.Added UL3OH float to Miscellaneous Parts page. 22-1201 Removed water hardness test strip.Updated Chemical Feeder Pumps section with black dot roller L 5-17-22 JH 22 1202 and corrected P/Ns and components.Added door magnet bracket to Door pages. Removed UL30 without heater and changed references of UL3OH to UL30. M 12-7-22 JH 8901 Changed chemical tubing.Updated peri-pumps to black components. 22-1505 N 5-16-23 JH 8905 New control panel,digital controls,door, kick panel,plumbing,rinse tank,and schematic for UH30- FND. P 11-13-23 JH 22-2163 Updated pen-pump assemblies.Added P/N for cable to displays.Changed strainer spacer P/N. Added UH3O-FND Display Wiring section. Updated UH3O-FND schematic. RECEIVED 10/10/2024 ASOEN BUILDING DEPARTMENT NOMENCLATURE WAREWASHING UH3O-FND Undercounter dishmachine; high-temperature, hot-water sanitizing, with a booster tank and detergent and rinse-aid chemical feeder pumps. U L30 Undercounter dishmachine; low-temperature with wash tank heater, chemical-sanitizing, with detergent, rinse-aid, and sanitizer chemical feeder pumps. The manufacturer provides technical support for all of the machines detailed in this manual. We strongly recommend that you refer to this manual before making a call to our technical support staff. Please have this manual open when you call so that our staff can refer you, if necessary, to the proper page. Technical support is not available on holidays. Contact technical support toll free at 1-888-800-5672. Technical support is available for service personnel only. RECEIVED 10/10/2024 ASHEN BUILDING DEPARTMENT TABLE OF CONTENTS GUIDES Symbols 1 Abbreviations &Acronyms 1 SPECIFICATIONS Machine Dimensions 2 Operating Parameters 3 Electrical Requirements 4 INSTALLATION Installation Instructions 5 Inspection 5 Unpacking 5 Plumbing 5 Water Supply Connections 5 Pressure Regulator 6 Shock Absorber 6 Connecting the Drain Line 6 Plumbing Check 6 Electrical Power Connections 7 Voltage Check 7 Surrounding Area 7 Thermostats 7 Chemical Feeder Equipment 8 Preparing Chemical Feeder Pumps 8 Priming Chemical Feeder Pumps 8 Programming Chemical Feeder Pumps (UL30) 9 Leveling 12 Initial Fill (UH3O-FND Only) 12 OPERATION Operating Instructions 13 Preparation 13 Filling the Wash Tub 13 Ware Preparation 14 Washing a Rack of Ware 14 Operational Inspection 14 Shutdown & Cleaning 15 Deliming UH3O-FND 17 Deliming UL30 18 Detergent Control 19 RECEIVED 10/10/2024 ASPEN BUILDING DEPARTMENT TABLE OF CONTENTS MAINTENANCE Preventative Maintenance 20 TROUBLESHOOTING UH3O-FND Setpoints 21 UH3O-FND Fault Codes 25 Troubleshooting 28 PARTS UH3O-FND Control Panel 30 UL30 Control Panel 32 UH3O-FND Display Panel 33 UL30 Display Panel 34 Terminal Block Box 35 UH3O-FND Chemical Feeder Pumps 36 UL30 Chemical Feeder Pump Assembly 37 UL30 Chemical Feeder Pumps 38 UH3O-FND Plumbing 39 UL30 Plumbing 41 Plumbing Options 43 Vacuum Breaker 44 Wash Manifold 45 Motor & Pump 47 Rinse Arms & Wash Arms 49 UH3O-FND Rinse Tank 51 UH3O-FND Door 52 UL30 Door 54 Miscellaneous Door Components 56 Frame & Panel Components 58 Miscellaneous Parts 60 Stands & Components 61 UL30 Heater Components 62 UL30 Vacuum Switch 63 UL30 Vacuum Switch Install 64 SCHEMATICS UH3O-FND 208-240 V, 50/60 Hz, 1/3 Phase 65 UL30 115 V, 50/60 Hz, 1 Phase 66 UH3O-FND Display Wiring 67 RECEIVED 10/10/2024 AthEN BUILDING DEPARTMENT GUIDES GUIDES SYMBOLS \I\ - Risk of Injury to Personnel WARNING N / 1 v - Risk of Damage to Equipment CAUTION - Risk of Electrical Shock A Caustic Chemicals 0 - Reference Data Plate V - Lockout Electrical Power NOTICE - Important Note I — - Instructions Hyperlink ❑- ABBREVIATIONS & ACRONYMS ANSI -American National Standards Institute Btu/Hr- British Thermal Units per Hour CFM - Cubic Feet per Minute GHT- Garden Hose Thread GPH - Gallons per Hour GPM - Gallons per Minute GPG - Grains per Gallon HP - Horsepower Hz- Hertz ID - Inside Diameter kW- Kilowatts MCA- Minimum Circuit Ampacity MOP - Maximum Overcurrent Protection NFPA- National Fire Protection Association NPT- National Pipe Thread OD - Outside Diameter PRV- Pressure Regulating Valve RECEIVED PSI - Pounds per Square Inch V-Volts 10/10/2024 07610-004-37-38-P ASftEN BUILDING DEPARTMENT SPECIFICATIONS MACHINE DIMENSIONS LEGEND A- Electrical Connection C- Drain Hose (1" ID, install into 1 1/2" MIN Drain with Air-gap) B-Water Inlet(with 6' Hose) (3/4" Male GHT, connect to true All dimensions from the floor can be increased 1" 1/2" ID line, MIN 110 °F) using the machine's adjustable feet. 24 1/4 `iIII-' 1!rc IiJ E 2 1/8 E c,--, E [54mm] Lu U ND EZ f A FRONT � Ez TOP NC, �' w CO cfl a 0 1 a E E E Mco coco V O �® _ir= 1 Z —W .- Eo o 0 ch E O a - — co CO CC 710 p I I I I .I. c' • II All ' CI I 1 �I■ C I ti BACK tallMachine Do NOT install ®Drain Hose into Drain Hose to * vi11/2[38 mm] "bottom"of FloorI !10hb0 A ,-' _ co _' _,1u MIN Floor Drain Drain or Sink. or Sink This can cause 00 E E Er I splashback. oo Nor__..._.L,_,'4 pal. ll0L,9 ,1 131 lik�W" 1 7/8 10 1/2 w.-, [48 mm] [267 mm] B Lc —E—' MN C RECEIVED NOTICE UH3O-FND shown. 10/10/2024 07610-004-37-38-P AS2EN BUILDING DEPARTMENT SPECIFICATIONS OPERATING PARAMETERS Operating Capacity: UH3O-FND UL30 Racks per Hour 24 24 Dishes per Hour 600 600 Glasses per Hour 864 864 Gallons per Rack 1.1 1.2 Gallons per Hour 26.4 28.8 Tank Capacity (Gallons): Wash Tank 1.1 1.2 Rinse Tank 3.0 N/A Electrical Loads (as applicable): Wash Motor HP 1.0 1.0 Rinse Heater kW 6.7 (208 V)/8.2 (230 V) N/A Wash Heater kW N/A 1.5 NOTICE Always refer to the machine data plate for specific electrical and water 0 requirements. The material provided on this page is for reference only and is subject to change without notice. HOT WATER SANITIZING Water Temperatures (°F): Minimum Wash Temperature 150 N/A Minimum Rinse Temperature 180 N/A Minimum Incoming Water Temperature 110 N/A CHEMICAL SANITIZING Water Temperatures (°F): Minimum Wash Temperature N/A 120 Minimum Rinse Temperature N/A 120 Minimum Incoming Water Temperature N/A 120 Other Water Requirements: Water Flow Pressure (PSI) 20 ± 5 20 ± 5 Flow Rate Minimum (GPM) 6.6 6.6 Water Line Connection Size (NPT) 3/4" GHT 3/4" GHT Water Line Size (NPT) 1/2" 1/2" Drain Line Size (NPT) 1" ID 1" ID NOTICE Install drain line into MIN 1 1/2"Drain with Air-gap. Minimum Chlorine Required (PPM) N/A RECEIVED 10/10/2024 07610-004-37-38-P AS@EN BUILDING DEPARTMENT SPECIFICATIONS ELECTRICAL REQUIREMENTS NOTICE Electrical Characteristics 0 © UH30-FND All electrical ratings provided in this manual are for reference VOLTS 208 230 only.Always refer to the machine data plate to get exact electrical information for this machine. All electrical work performed on machines should be done in accordance with applicable PHASE 1 1 local, state, territorial, and national codes. Work should only be performed by qualified electricians and authorized service agents. FREQ 60 60 The electrical configurations of this series of machines are as follows: WASH MOTOR 5.O A 5.O A Available Electrical Characteristics: AMPS UH30-FND RINSE • 208 V, 60 Hz, Single-phase HEATER 32.2 A 35.7 A • 230 V, 60 Hz, Single-phase AMPS UL30 TOTAL 37.2 A 40.7 A • 115 V, 60 Hz, Single-phase LOAD Available Wash Tank Heater: UL30 • 1.5 kW (UL30 Only) *Motor and heater do not operate at same time. Total load based VOLTS 115 on motor load. PHASE 1 FREQ 60 I WASH MOTOR 10.0 A AMPS WASH HEATER 13.0 A AMPS TOTAL 10.0 A* LOAD RECEIVED 10/10/2024 07610-004-37-38-P AS4EN BUILDING DEPARTMENT INSTALLATION INSTRUCTIONS INSPECTION Before installing the unit, check packaging and machine for damage. Damaged packaging might be an indication of damage to the machine. If there is any type Do not throw away of damage to both packaging and unit, do not throw away the packaging. The container if damage is dishmachine has been inspected at the factory before shipping and is expected evident! to arrive in new, undamaged condition. However, rough handling by carriers or others might result in damage to the unit while in transit. If this occurs, do not return the unit to the manufacturer. Instead, contact the carrier and ask them to send a representative to the site to inspect the damage and request that an inspection report be completed. Contact the carrier within 48 hours of receiving the machine as well as the dealer that sold you the unit. UNPACKING Remove the box and machine from the pallet before installing. Open the front door and remove all of the materials from inside. Once unpacked, verify there are no missing parts (reference the Parts section). If a part is missing, contact the manufacturer immediately. PLUMBING All plumbing connections must be made to adhere to local, state, territorial, and national codes. The installing plumber is responsible for ensuring the incoming water lines are flushed of debris before connecting to the machine. Note that chips and materials from cutting processes can become lodged in the solenoid valves The plumber must flush and prevent them from opening or closing.Any valves that are found to be fouled the incoming water line! or defective because of foreign matter left in the water line, and any subsequent damage, are not the responsibility of the manufacturer. A water hardness test must be performed.A hardness test kit can be found on the warning tag that is attached to the incoming plumbing connection on the back of the A water hardness test machine. If water hardness is higher than 3 GPG, install a water softener or install must be performed. the optional Scale Prevention System (SPS). See the Plumbing Options page and the next section for more information on the SPS. See the Machine Dimensions page and reference item "B"for water inlet connection location. NOTICE The manufacturer does NOT endorse "Tankless On-demand"water heaters for use with their dishmachines. The manufacturer DOES endorse, and highly recommends, the standard "Tank"style water heaters, sized to properly handle the water heating requirements of the facility. RECEIVED 10/10/2024 07610-004-37-38-P AS5EN BUILDING DEPARTMENT INSTALLATION INSTRUCTIONS WATER SUPPLY Awater hardness test must be performed. If water hardness is higher than 3 GPG CONNECTIONS: and a water softener is not being used, install an SPS (see Plumbing Options page) into the water line between the facility water line and the machine water line WATER HARDNESS (installed at the factory). Observe proper inlet/outlet water directions. A water shut- HIGHER THAN 3 GPG off valve should be installed before installing the SPS to allow access for service. The water supply must be capable of a minimum of 20 ± 5 PSI "flow" pressure at the recommended temperature indicated on the data plate. Facility Shut-off Adapter SPS Adapter Machine Water Line Valve Water Line EINCI 1 1 Example AM! nna9on�t U nmr�onu� 1# I *Adapters needed will vary. WATER SUPPLY If water hardness tests at 3 GPG or lower, connect the machine water line (installed CONNECTIONS: at the factory)to the facility water line. A water shut-off valve should be installed in the water line between the facility supply and the machine to allow access for WATER HARDNESS service. The water supply line must be capable of a minimum of 20 ± 5 PSI "flow" LOWER THAN 3 GPG pressure at the recommended temperature indicated on the data plate. PRESSURE The manufacturer has an optional water pressure regulator to accommodate areas REGULATOR where water pressure fluctuates or is higher than the recommended pressure. Take care not to confuse static pressure with flow pressure: static pressure is line pressure Take care not to confuse in a "no flow" condition (all valves and services are closed); flow pressure is the static pressure with pressure in the fill line when the valve is opened during the cycle. See the Plumbing flow pressure! Options page. SHOCK ABSORBER It is suggested that a shock absorber(not supplied) be installed on the incoming water line. This prevents water hammer(hydraulic shock)—induced by the solenoid valve as it operates—from causing damage to the equipment. See the Plumbing Options page. CONNECTING THE The dishmachine has a pumped (pressure) drain capable of pumping waste water DRAIN LINE to a height of 24" above the floor to the kitchen's drain system. Each dishmachine is supplied with a drain hose. When installed, it will extend from the rear side of the machine. There must be an air-gap between the machine drain line and the floor sink or drain. If a grease trap is required by code, it should have a flow capacity of 12 GPM. PLUMBING CHECK After installing the incoming fill line and the drain line, slowly turn on th (r� { -VED ply to the machine. Check for any leaks and repair as required.All leaks must be repaired before operating the machine. 10/10/2024 07610-004-37-38-P ASBEN BUILDING DEPARTMENT INSTALLATION INSTRUCTIONS ELECTRICAL POWER Electrical and grounding conductors must comply with the applicable portions of the CONNECTIONS National Electric Code ANSI/NFPA 70 (latest edition) and/or other electrical codes. �., The data plate is located at the left-front side of the dishmachine. Refer to the data •(a \) plate for machine operating requirements, machine voltage,total amperage, and serial A number. Disconnect electrical Remove the back panel and set aside. This will require removing the screw at the power at the breaker or bottom of the back panel with a phillips screwdriver. Install 3/4" conduit into the pre- disconnect switch and punched holes in the back of the control box. Route power wires and connect to power tag-out in accordance with block and grounding lug. Install the service wires (L1 and L2 for UH3O-FND, Li and procedures and codes. N for UL30)to the appropriate terminals as they are marked on the terminal block. Install the grounding wire into the lug provided. It is recommended that"DE-OX" or another similar anti-oxidation agent be used on all power connections. UH3O-FND UL30 if itioilTils A ,......., • or.,,,,,,,,... tiwati _ mi imil A .._ VOLTAGE CHECK Ensure the ON/OFF switch is in the OFF position and apply power to dishmachine. Check the incoming power at the terminal block and ensure it corresponds with the voltage listed on the data plate. If not, contact a qualified service agency to examine \ e the problem. Do not run dishmachine if voltage is too high or too low. Shut-off the service breaker and advise all proper personnel of the location of the breaker and any problems. Replace the control box cover and tighten-down the screws. SURROUNDING This is a commercial dishmachine and reaches temperatures that can exceed AREA those generated by a residential machine. Surrounding countertops, cabinets,flooring material, and subfloor material must be designed and/or selected with these higher temperatures in mind. NOTICE Any damage to surrounding area that is caused by heat and/or moisture to materials that are not recommended for higher temperatures will not be covered under warranty or by the manufacturer. THERMOSTATS The thermostats on this dishmachine have been set at the factory. ThRECElED be adjusted by an authorized service agent. �/ 10/10/2024 07610-004-37-38-P ASFEN BUILDING DEPARTMENT INSTALLATION INSTRUCTIONS CHEMICAL FEEDER CAUTION! Chlorine-based sanitizers can be detrimental to this machine EQUIPMENT ' if the chemical solution is too strong. See a chemical professional to CAUTION ensure the dispenser is set-up correctly. The bottom of the chemical container cannot be located any higher than 8"from the floor. If the unit is equipped with the 6"or 18"table stand, the highest position will be 14" or 26"from the floor, respectively. It is important to remember that if you decide to operate the unit in chemical-sanitizing mode, you must ensure an appropriate chlorine-based sanitizer is used in the final rinse line. PREPARING The UH30-FND dishmachine is supplied with detergent and rinse-aid chemical CHEMICAL FEEDER feeder pumps. PUMPS The UL30 dishmachine is supplied with detergent, rinse-aid, and sanitizer chemical feeder pumps. Locate the open ends of the chemical tubes with the tube stiffeners and place each one in the appropriate container. • Red Tubing = Detergent • Blue Tubing = Rinse-Aid • White Tubing = Sanitizer PRIMING CHEMICAL Chemical feeder pumps need priming when the machine is first installed or if the FEEDER PUMPS chemical lines have been removed and air was allowed to enter. CAUTION! Water must be in the sump and wash tank before chemicals CATION are dispensed. WARNING U H 30-F N D 1. Press and hold prime button toward DETERGENT PRIME until display shows WARNING! Some of the timer. Priming cycle defaults to 70 seconds. Observe wash tank during priming chemicals used in cycle. If too much detergent, press prime button to stop priming cycle. If not dishwashing might cause enough, run priming cycle again. chemical burns if they come in contact with skin. -, Wear protective gear when handling these chemicals. 'iu _ If any contact with skinAir occurs, immediately follow the treatment 2 Press and hold prime button toward RINSE AID PRIME until display shows instructions provided timer. Priming cycle defaults to 180 seconds. with the chemicals. 0 Alr„ieule. DETERGENT 'INSPRIME E ge AID Alimrn:ar POWER &ergo eier3enie Ayda Emua ® I n n • NORMAL EXTRA HEAVY• a 414. NE TampneNre de LevadD Normal Muy Diflcil P vc ale juagn D I! I .I— • HEAVY DELIME • Temperatira de F,Jua3o Diflrl Descalcificacion • 2024 07610-004-37-38-P ASOEN BUILDING DEPARTMENT INSTALLATION INSTRUCTIONS PRIMING CHEMICAL 3. The amount of detergent might need adjustment depending on water quality and FEEDER PUMPS type of detergent. The amount of rinse-aid might need adjustment depending on water hardness and results. Refer to UH3O-FND Setpoints section for instructions on adjusting amount of chemicals being dispensed. UL30 4. Hold each prime switch (Detergent, Rinse-aid, and Sanitizer) until the respective chemical can be seen entering the wash tank. Iml 0 = p O O O 5. Detergent is dispensed as required during the wash cycle by the timer. The amount of detergent might need to be increased or decreased depending upon water quality and type of detergent. 6. Rinse-aid is dispensed as required into the final rinse. The amount of rinse-aid might need to be adjusted depending upon water hardness and results. 7. Sanitizer is dispensed proportionally into the final rinse water line. The amount of sanitizer might need to be adjusted depending on concentration. 8. See Programming Chemical Feeder Pumps (UL30)section to adjust chemical amounts using the universal timer. PROGRAMMING To access programming mode, machine must be ON and between cycles. CHEMICAL FEEDER The PROGRAM(PGM) light will be flashing. PUMPS (UL30) 1. Locate universal timer. On the timer, locate programming board and programming buttons. _ 1 �� - i UL30 DIP-switch Settings 1, 00 Io0oso000l `— (0=On,X=Off) ■ , OO X XXX II ON 0 0 0 0 y 8 7 6 5 4 3 2 1 1 0 I CIO) 0 Universal timer is ■ located on control panel. Use Parts section of this' O manual for reference. o; -- la. rikilialinaM IEIVED i 10/2024 07610-004-37-38-P Ell AS9EN BUILDING DEPARTMENT INSTALLATION INSTRUCTIONS PROGRAMMING 2. Programming board and buttons are not labeled on the timer. Use the graphic CHEMICAL FEEDER below for reference. PUMPS (UL30) ) LIGHTS TIME IN 1 SEC PGM A I I 8 B I 4 C I I 2 I D I I 1 E I I 0.8 F I I 0.4 G I I 0.2 H O] 0.1 ACCEPT L I , I MOVE 0 BUTTONS ENTER 0 I I Cl/1/ 11 3. Press and hold both the MOVE and ENTER buttons simultaneously for two seconds then release. PGM light will go steady and light A will start flashing. LIGHTS TIME IN SEC PGM A ® 8 B I 4 C I 2 = Light Steady I I 08 E I I 0.8 F I I = Light Flashing H I I 0.2 ACCEPT I I MOVE BUTTONS ENTER /// 4. Press MOVE button to move the flashing light to E, F, G, or H. Options A—D are not adjustable. LIGHTS TIME IN SEC PGM f ' A O 8 PGM UL30 B O 4 c O 2 Example here shows E Rinse aid D E o o1s option G(sanitizer) F Fill F O o4 being selected. H O 0.1 G Sanitizer ACCEPT I I H Detergent MOVE C() BUTTONS ENTER RECEIVED 10/10/2024 07610-004-37-38-P AWN BUILDING DEPARTMENT INSTALLATION INSTRUCTIONS PROGRAMMING 5. Press ENTER button. PGM light will stay steady, lights for the current time CHEMICAL FEEDER setting will come on,\and ACCEPT light will start flashing. PUMPS (UL30) J LIGHTS TIME IN SEC PGM A 8 B I I 4 Example here shows D 1 current setting for G _ = Light Steady E I I 0.4 at 9.2 seconds(each G 0.2 selected time option I I = Light Flashing ACCEPH T ® 0.1 is added to get the , total). MOVE fl BUTTONS ENTER p 1 _ 6. Press MOVE button to cycle through the different time options. To choose a time option, press ENTER while the light is flashing on that option. To deselect the option, press ENTER again. LIGHTS TIME IN PGM A I I 8 ■ B 4 C CAUTION C 2 Example here shows D 0 1 setting for G changed CAUTION! Light for each F 0.4 to 6.5 seconds(each desired option must be G o 0.2 selected time option steady before moving on. ACCEPT II 0.1 is added to get the total). MOVE BUTTONS ENTER // 1 / 7. Once all desired time options are selected, press MOVE button until ACCEPT light is flashing (lights for selected time options should still be steady). LIGHTS TIME IN SEC PGM A I I 8 B MI 4 C 2 = Light Steady E II I I 0.8 F 0.4 I I = Light Flashing G I I 0.2 H 0.1 ACCEPT ® , MOVE BUTTONS ENTER RECEIVED 10/10/2024 07610-004-37-38-P ASitN BUILDING DEPARTMENT INSTALLATION INSTRUCTIONS PROGRAMMING 8. Press ENTER button. This saves the changed parameters and exits the CHEMICAL FEEDER programming mode. PGM light will go from steady to flashing. PUMPS (UL30) LIGHTS TIME IN SEC PGM ® V A I I 8 B I I 4 C 0 2 D I I 1 E I I 0.8 F I I 0.4 G I 0.2 H I I 0.1 ACCEPT , I „ MOVE n BUTTONS ENTER�� \ 9. To change any other values, repeat the process above. To revert back to a previous setting, repeat the process above and change parameters back to previous settings. In programming mode, if there have been no keypad inputs for approximately two minutes, the system will automatically exit out of programming mode.Any changes to parameters will be lost when programming mode is automatically exited. LEVELING The dishmachine is designed to operate while level. This is important to prevent any damage to the machine during operation and to ensure the best possible results. The unit comes equipped with adjustable bullet feet which can be turned using a pair of pliers. Since this machine is an undercounter unit, it should be leveled as close as possible to the unit's location before it is pushed under the counter. INITIAL FILL 1. Press POWER button and listen for machine to stop filling. (UH30-FND ONLY) 2. Press POWER button and listen for machine to stop draining. 3. Repeat Steps 1 and 2. UH3O-FND models with serial numbers before 4. Press POWER button and listen for machine to stop filling. 23D415452 have different 5. Machine is now ready for operation. initial fill instructions. Click here to open earlier manual. 117 D) ) x2 RECEIVED 10/10/2024 07610-004-37-38-P AN BUILDING DEPARTMENT OPERATION OPERATING INSTRUCTIONS PREPARATION Before operating machine, verify: 1. Strainer is in place and clean. 2. Wash and rinse arms are screwed securely into place and end-caps are tight. UL30 has combined wash/ rinse arms. �4'� 3. Wash and rinse arms rotate freely. • I/ 13 4. Chemical levels in chemical containers are correct. FILLING THE 1. Close door. WASH TUB 2. Turn machine on. UH3O-FND UL30 See Initial Fill section a�`°° oo o — — for UH3O-FND models. ct,,,r) m..EGA. o 0 0 3. Machine will automatically begin to fill. 4. Once wash tub is filled, wait until wash temperature is at least 150 °F for UH30- FND and 120 °F for UL30 before operating machine. RECEIVED 10/10/2024 07610-004-37-38-P A&N BUILDING DEPARTMENT OPERATION OPERATING INSTRUCTIONS WARE Properly preparing ware will help ensure good results and fewer re-washes. If not PREPARATION done properly, ware might not come out clean and the efficiency of the machine will be reduced. Putting unscraped dishes into the machine affects its performance, so alwasys remove scraps from ware before loading into a rack. Pre-rinsing and pre- soaking are good ideas, especially for silverware and casserole dishes. Place cups and glasses upside-down in racks so they don't hold water during the cycle. The dishmachine sanitizes as well as cleans. To do this, ware must be properly prepared before being placed in the machine. WASHING A RACK UH3O-FND OF WARE 1. Ensure machine is on and at operating temperature. 2. Open door and load rack. 3. Push START button. III III ¶ 4. LED will turn green. Operator has three seconds to close door before LED goes out and START button must be pressed again. 5. Cycle automatically starts when door is closed. UL30 1. Ensure machine is on and at operating temperature. 2. Open door and load rack. 3. Close door and ensure WASH/DELIME switch is on WASH. 4. Push START button. Cycle light comes on and cycle automatically starts. OPERATIONAL Based on use, the strainer might become clogged with soil and debris as the INSPECTION workday progresses. Operators should regularly inspect the strainer to ensure it has not become clogged. If clogged, it will reduce the washing capability of - Instruct operators to clean out the strainer at regular intervals or as re•ti �. .. �,/ workload. 10/10/2024 07610-004-37-38-P A5' N BUILDING DEPARTMENT OPERATION OPERATING INSTRUCTIONS SHUTDOWN & 1. At end of workday, close door. UH3O-FND: Press POWER button. UL30: Flip ON/ CLEANING OFF switch to OFF position. UH3O-FND UL30 = clEFE? / t0 0 ld ; : ':' \ 2. Drain pump will activate and empty machine of water. 3. When draining stops, remove strainer. .o C eu 'r o i 4. Remove soil and debris from strainer and set aside. Meg WOE ggaimme ImgaggE AMO.SW.MAWN ee8 CAUTION eg gg E °����='^#a�����^'wee vaaae c asba� e�a�r CAUTION! Do NOT beat almm;ee e, strainers to remove �e ;e ANS �a$�e�$ae�e�e�e$aaee soil and debris! ` `� '8g° ea fealn8 B oe EIS IC WA a a 5. Unscrew wash and rinse arms manifolds. Remove end-caps and flush arms with water. Use a brush to clean inside of the arms. If nozzles appear to be clogged, use a toothpick to remove debris. ri II 1 UL30 has combined wash/ 'O40, 1111 rinse arms. Nozzle r End-cap Ir % RECEIVED 10/10/2024 07610-004-37-38-P A&N BUILDING DEPARTMENT OPERATION OPERATING INSTRUCTIONS SHUTDOWN & 6. Wipe inside of machine out, removing all soil and scraps. CLEANING i-l+ 0 in 41,1 `i 111 7. Reassemble wash and rinse arms. 8. Replace wash and rinse arms.The arms only need to be hand-tight, do not use tools to tighten them down. UL30 has combined wash/ ,) rinse arms. 9. Reinstall strainer and close door. 1 le el v4II watt SEAR : RECEIVED 10/10/2024 07610-004-37-38-P AWN BUILDING DEPARTMENT OPERATION OPERATING INSTRUCTIONS DELIMING 1. Remove rinse arms and place in sink with deliming solution (leave for amount of UH3O-FND time recommended by chemical supplier). If machine is equipped with an SPS and lime is becoming a frequent problem, the cartridgeksszt needs to be replaced. To order a replacement cartridge, call the manufacturer. 2. Replace rinse arms. 3. If the machine is full of water, close door, press power button, and allow the machine to drain and shut-off. 4. Follow Filling the Wash Tub section of this manual. 5. Open door and add amount of deliming solution recommended by chemical supplier. 6. Use cycle button to select Delime. oa o-a11311 . . O P R _. les= i i I of I_IL I I 7. Close door and the machine will begin delime cycle. Cycle timer shows on right display. LED on power button will turn green. o=„ M ';:E O oo Jm Ii it o —litO 1 I_I!I i_I_I mrn 8. The machine will delime, drain, and refill. When cycle is complete right display will turn off. 9. Wait five minutes and inspect the machine. If the machine is not delimed, run again. 10. When clean, use cycle button to select Normal. ;,e PaME"'® PaME PowER I[i I of r I_I!I 1 11. Run two Normal cycles to remove residual deliming solution.12. The machine is now ready for normal operation. RECEIVED 10/10/2024 07610-004-37-38-P AITN BUILDING DEPARTMENT OPERATION OPERATING INSTRUCTIONS DELIMING 1. Flip ON/OFF switch to ON position. U L30 If machine is equipped o a = 0 with an SPS and lime is o 0 becoming a frequent problem, the cartridge 2. Flip WASH/DELIME switch to DELIME position. needs to be replaced. To order a replacement cartridge, call the 0 0 manufacturer. om = = = 0 0 3. Add deliming solution per chemical supplier's instructions. 4. Close door. 5. Push START button. 6. Wait until cycle is complete and inspect inside of machine. If machine is not delimed, run again. NOTICE UH3O-FND and UL30: This equipment is not recommended for use with deionized water or other aggressive fluids. Use of deionized water or other aggressive fluids will result in corrosion and failure of materials and components. Use of deionized water or other aggressive fluids will void the manufacturer's warranty. RECEIVED 10/10/2024 07610-004-37-38-P AS1$N BUILDING DEPARTMENT OPERATION OPERATING INSTRUCTIONS DETERGENT Detergent usage and water hardness are two factors that greatly contribute to the CONTROL machine's operating efficiency. Using the proper amount of detergent can become a source of substantial savings.A qualified water-treatment specialist can determine what is needed for maximum efficiency from the detergent. • Hard water greatly affects the performance of the machine, causing the amount of detergent required for washing to increase. If the machine is installed in an area with hard water, the manufacturer recommends the installation of water treatment equipment. • Deposited solids from hard water can cause spotting that will not be removed with a drying agent. Treated water will reduce this occurence. • Treated water might not be suitable for use in other areas of operation and it might be necessary to install a water treatment system for the water going to the machine only. Discuss this option with a qualified water treatment specialist. • Properly train operators on how much detergent is to be used per cycle. Meet with a water treatment specialist and chemical supplier to discuss a complete training program for operators. • Water temperature is an important factor in ensuring the machine functions properly, and the machine's data plate details what the minimum temperatures O must be for the incoming water supply, the wash tank, and the rinse tank. If minimum requirements are not met, it's possible that dishes will not be clean or sanitized. • Instruct operators to observe the required temperatures and to report when they fall below the minimum allowed.A loss of temperature can indicate a larger problem. RECEIVED 10/10/2024 07610-004-37-38-P AWN BUILDING DEPARTMENT MAINTENANCE PREVENTATIVE MAINTENANCE PREVENTATIVE The manufacturer highly recommends that only qualified service personnel perform any MAINTENANCE maintenance and repairs not specifically discussed in this manual. WARNING! Unqualified personnel performing maintenance on the machine may void the warranty, lead to larger problems, or cause harm to the operator. ■ WARNING By following the operating and cleaning instructions in this manual, you should get the most efficient results from your machine.As a reminder, here are some steps to take to ensure that you are using the dishmachine the way it was designed to work: 0 1. Ensure the water temperatures match those listed on the machine data plate. There can be a variety of reasons why your water temperature could be too low. 2. Ensure all strainers are clean and securely in place before operating the machine. CAUTIONN When cleaning out strainers, do NOT beat them on waste cans. Wipe out strainers \ with a rag and rinse under a faucet if necessary. Use a toothpick to dislodge any CAUTION! stubborn debris. Do NOT beat strainers to remove debris! 3. Ensure all wash and rinse arms are secure in the machine before operating. 4. Remove as much soil from dishes by hand as possible before loading into racks. 5. Do not overfill racks. 6. Ensure glasses are placed upside-down in the rack. 7. Ensure all chemicals being injected into machine have been verified at the correct concentrations. 8. Clean out the machine at the end of every workday per the Shutdown and Cleaning section of this manual. 9. Follow all safety procedures,whether listed in this manual or put forth by local, state, or national codes/regulations. RECEIVED 10/10/2024 07610-004-37-38-P AnN BUILDING DEPARTMENT TROUBLESHOOTING UH3O-FND SETPOINTS RINSE TEMP To access Setpoints, the machine must be on and not in cycle. 1. Push and hold cycle button a minimum of six seconds. Temperature shows on left display and will flash on and off. Adjustable Setpoints: EM®-zr o Rinse Temp ." Drain Time 180 F Detergent Time Rinse-aid Time 2. Once button is released, press prime button (left rocker to increase and Detergent Priming Time right rocker to decrease). This changes rinse temp one degree at a time to a Rinse-aid Priming Time maximum of 192 °F or a minimum of 180 °F. Temperature Scale IUD of 3. Once desired temperature is selected, press and hold cycle button a minimum of three seconds and no more than five seconds (after three seconds temperature will stop flashing). Release cycle button to accept and move to next setpoint(drain time). ion F 7� DRAIN TIME 1. Once setting changes to drain time, current setting shows on left display and will flash on and off. ..® .,.. ., 0 a If there is no activity (button presses) for 30 seconds, display will exit 2. Press prime button (left rocker to increase and right rocker to decrease). This Setpoints mode without changes drain time one second at a time. saving changes. To exit Setpoints at any 20 time, hold cycle button a minimum of six seconds. 3. Once desired time is selected, press and hold cycle button a minimum of three Display will stop flashing seconds and no more than five seconds (after three seconds time will stop and return to wash flashing). Release cycle button to accept and move to next setpoint (detergent temperature. Machine is time). ready to operate. ® a.E 2n 0 U RECEIVED 10/10/2024 07610-004-37-38-P AktN BUILDING DEPARTMENT TROUBLESHOOTING UH3O-FND SETPOINTS DETERGENT 1. Once setting changes to detergent time, current setting will flash on and off. TIME m-si oa If there is no activity (button presses) for 30 seconds, display will exit 2. Press prime button (left rocker to increase and right rocker to decrease). This Setpoints mode without changes detergent time one second at a time. saving changes. ooa .... 3. Once desired time is selected, press and hold cycle button a minimum of three seconds and no more than five seconds (after three seconds time will stop flashing). Release cycle button to accept and move to next setpoint(rinse-aid time). ..®W.. ... ink cm= U RINSE-AID 1. Once setting changes to rinse-aid time, current setting will flash on and off. TIME �. ®. o To exit Setpoints at any time, hold cycle button a minimum of six seconds. 2. Press prime button (left rocker to increase and right rocker to decrease). This Display will stop flashing changes rinse-aid time one second at a time. and return to wash temperature. Machine isa ready to operate. E I 3. Once desired time is selected, press and hold cycle button a minimum of three seconds and no more than five seconds (after three seconds time will stop flashing). Release cycle button to accept and move to next setpoint(detergent priming time). n 0 V RECEIVED 10/10/2024 07610-004-37-38-P AWN BUILDING DEPARTMENT TROUBLESHOOTING UH3O-FND SETPOINTS DETERGENT 1. Once setting changes to detergent priming time, current setting will flash on and PRIMING TIME off. R ... 0 If there is no activity (button presses) for 30 seconds, display will exit 2. Press prime button (left rocker to increase and right rocker to decrease). This Setpoints mode without changes detergent priming time one second at a time. saving changes. O - 3. Once desired time is selected, press and hold cycle button a minimum of three seconds and no more than five seconds (after three seconds time will stop flashing). Release cycle button to accept and move to next setpoint(rinse-aid priming time). 0 . C=1=III RINSE-AID 1. Once setting changes to rinse-aid priming time, current setting will flash on and PRIMING TIME off. To exit Setpoints at any = time, hold cycle button a minimum of six seconds. 2. Press prime button (left rocker to increase and right rocker to decrease). This Display will stop flashing changes rinse-aid priming time one second at a time. and return to wash temperature. Machine is =El 0 . - ready to operate. l l I 3. Once desired time is selected, press and hold cycle button a minimum of three seconds and no more than five seconds (after three seconds time will stop flashing). Release cycle button to accept and move to next setpoint(energy saver on/off). V RECEIVED 10/10/2024 07610-004-37-38-P A2N BUILDING DEPARTMENT TROUBLESHOOTING UH3O-FND SETPOINTS TEMPERATURE 1. Once setting changes to temperature scale, °F or°C will flash on and off. SCALE o If there is no activity (button presses) for 30 seconds, display will exit 2. Press prime button to switch to other setting. Setpoints mode without saving changes. To exit Setpoints at any time, hold cycle button a minimum of six seconds. 3. Once desired scale is selected, press and hold cycle button a minimum of three Display will stop flashing seconds and no more than five seconds (after three seconds scale will stop and return to wash flashing). Release cycle button to accept and move to next setpoint(back to temperature. Machine is wash temp). ready to operate. w RECEIVED 10/10/2024 07610-004-37-38-P AWN BUILDING DEPARTMENT TROUBLESHOOTING UH3O-FND FAULT CODES DISPLAY SHOWS POSSIBLE CAUSES REMEDY 1.Verify incoming water pressure is 10±2 PSI. 1. Low or no water pressure. 2.Verify that fill relay is supplying voltage to fill solenoid. 2. Faulty inlet valve or fill relay. Replace faulty component. 3. Contactor to booster heater not turning off. 3. Check for welded contacts.Verify that output from 10 module turns off when above the set temperature. "Fl Service needed," 4. Faulty temperature input(P12)on 10 "No water in Booster" module. 4. Substitute a 1.2 kQ resistor for T3, and verify that booster heater turns off. If not, replace 10 module. 5. Faulty temperature probe (T3). 5.Verify that the booster-probe resistance is correct with 6. Faulty float switch allows heaters to respect to temperature(see table on pg. 24). If not, replace operate with no water in tub. T3. 6. Replace float switch. 1. Check for welded contacts.Verify that output from 10 1.Contactor to booster heater not turning off. module turns off when above the set temperature. "F2 Service needed," 2 Faulty temperature input(P12)on 10 module. 2. Substitute a 1.2 kQ resistor for T3, and verify that booster "Check booster heater turns off. If not, replace 10 module. thermostat" 3. Faulty temperature probe(T3). 3.Verify that the booster probe resistance is correct with respect to temperature(see table on pg. 24). If not, replace T3. 1. Malfunction of fill solenoid or fill relay. 1. Replace faulty component. "F3 No water in wash tank,""Check inlet 2. Door is open,which inhibits fill mode. 2. Close door to activate door switch. water and door" 3. Faulty door switch. 3. Replace or adjust door switch. "F4 Service needed," 1. Incoming power not properly connected. 1. Check connections to heater. "Check incoming 2. L3 is missing (3-phase machines only). 2. Verifythat L3 ispresent and connectedproperly. power" ( p 1. Substitute a 1.81(0 resistor for T3, and verify that booster heater turns on. If not, replace 10 module. 1. Faulty temperature input(P12)on 10 2.Verify that T3 resistance is consistent with the table on module. pg. 24. If not, replace T3. "F5 Service needed," 2. Faulty temperature probe (T3). "Check booster3. Replace high-limit switch. thermostat and high 3. Faulty high-limit switch. limit" 4. Check booster heater for proper resistance. Replace if 4. Faulty booster heater. incorrect. 5. Booster heater contactor not energizing. 5.Verify that drive voltage to contactor coil is present during a call for heat and that contactor closes. If voltage is present, replace contactor. If voltage is not present, check wiring. RECEIVED 10/10/2024 07610-004-37-38-P A&N BUILDING DEPARTMENT TROUBLESHOOTING UH3O-FND FAULT CODES DISPLAY SHOWS POSSIBLE CAUSES REMEDY 1.Verify incoming water pressure is 10±2 PSI. 1. Low or no water pressure. 2.Verify that fill relay is supplying voltage to fill solenoid. 2. Faulty inlet valve or fill relay. Replace faulty component. 3. Contactor to wash heater not turning off. 3. Check for welded contacts.Verify that output from 10 "F6 Service needed," module turns off when above the set temperature. "No water in wash tank" 4. Faulty temperature input(T1)on 10 module. 4. Substitute a 1.2 kQ resistor for T1, and verify that wash heater turns off. If not, replace 10 module. 5. Faulty temperature probe (T1). 5.Verify that T1 resistance is correct with respect to 6. Faulty float switch allows heaters to temperature(see table on pg. 24). If not, replace Ti. operate with no water in tub. 6. Replace float switch. 1. Check for welded contacts.Verify that output from 10 1. Contactor to wash heater not turning off. module turns off when above the set temperature. "F7 Service needed," 2. Faulty temperature input(P10)on 10 2. Substitute a 1.2 kf2 resistor for Ti, and verify that wash "Check wash tankmodule. heater turns off. If not, replace 10 module. thermostat" 3. Faulty temperature probe (T1). 3.Verify that T1 resistance is correct with respect to temperature(see table on pg. 24). If not, replace Ti. 1. Malfunction of fill solenoid or fill relay. 1. Replace faulty solenoid or fill relay. "F8 No water in wash tank,""Check inlet 2. Door is open,which inhibits fill mode. 2. Close door to activate door switch. water and door" 3. Faulty door switch. 3. Replace or adjust door switch. "F9 Service needed," 1. Incoming power not properly connected. 1. Check connections to heater. "Check incoming power" 2. L3 is missing (3-phase machines only). 2.Verify that L3 is present and connected properly. 1. Substitute a 1.8 kf2 resistor for T1, and verify that wash 1. Faulty temperature input(T1)on I/O heater turns on. If not, replace I/O module. module. 2.Verify that T1 resistance is correct with respect to "F10 Service needed," 2. Faulty temperature probe (Ti). temperature(see table on pg. 24). If not, replace Ti. "Check wash tank 3. Faulty high limit switch. 3. Replace high-limit switch. thermostat and high limit" 4. Faulty wash heater. 4. Check wash heater for proper resistance. Replace if incorrect. 5. Wash heater contactor not energizing. 5.Verify that drive voltage to contactor coil is present during a call for heat and that contactor closes. If voltage present, replace contactor. If voltage not present, check wiring. F11 Service needed -check wash tank Faulty temperature probe(T1). Replace probe that connects to P10. thermostat RECEIVED 10/10/2024 07610-004-37-38-P AnN BUILDING DEPARTMENT TROUBLESHOOTING UH3O-FND FAULT CODES DISPLAY SHOWS POSSIBLE CAUSES REMEDY "F12 Service needed," "Check booster Faulty temperature probe(T3). Replace probe that connects to P13. thermostat" 1. Fully disconnect 6-pin cable at each end, and reconnect 1. Loose connection in 6-pin cable between each end until a click is heard. display board and I/O module. 2. Inspect for broken wire or unseated terminal by gently "F13 Communication 2. Faulty 6-pin cable between display board pulling on each wire at each end of the cable. Reseat any error," and I/O module. loose terminals by inserting it fully into the housing using "Check 6-pin cable" long-nosed pliers. Replace cable if broken wire is found. 3. Faulty communication port on I/O module or display board. 3.Temporarily substitute a verified good display board, and check if F13 message recurs. If so, repeat substitution with a good I/O module. 1. Low or no water pressure. "F14 Service needed," 1.Verify correct PSI. "Check incoming 2. Faulty pressure switch. water pressure or 2. Replace pressure switch. pressure switch" 3. Faulty fill valve or fill valve not receiving 3. Check continuity and replace if faulty. power. "F16 LLC violation" Faulty or corroded probe. Clean or replace probe. "F17 Excessive inlet Inlet water supply too hot. Ensure inlet water supply is at required temperature. temp" RESISTANCE-TO-TEMPERATURE VALUES R(kQ) °F 11.58 69.8 10.37 75.2 9.30 80.6 7.78 89.6 3.05 140.0 2.54 150.8 2.18 159.8 1.58 179.6 1.45 185.0 1.33 190.4 1.16 199.4 0.96 212.0 RECEIVED 10/10/2024 07610-004-37-38-P AS$1N BUILDING DEPARTMENT TROUBLESHOOTING TROUBLESHOOTING WARNING! Inspection, testing, and repair of electrical equipment should only be performed by qualified service personnel. Certain procedures in this section require electrical tests or measurements while power is applied WARNING to the machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect power, attach test equipment, and reapply power to test. When replacing electrical parts, disconnect power at source circuit breaker. OBSERVATION POSSIBLE CAUSE REMEDY Water overflow 1. Clogged drain. 1. Remove obstruction. from bottom of door. 2. Machine not level. 2. Level machine or increase height to the front. 3. Excessive inlet pressure. 3. Install pressure regulator or adjust if one is present. Ensure flow meets data plate specification. 4. Detergent foaming. 4. Reduce detergent quantity. 5. Wash/rinse arm end-cap missing. 5. Replace. Wash motor 1. Loose or broken wires. 1. Reconnect or replace wires in motor. doesn't operate on 2. Defective WASH/DELIME switch. 2. Verify WASH/DELIME switch triggers input on PLC. If delime wash. not, check wiring/replace membrane. 3. Defective motor starting relay. 3. Replace. 4. Machine in FAULT mode and locked out. 4. Review fault screen for active faults. No water comes through the arms when 1. Water not turned on. 1. Turn water on. the WASH/ DELIME switch 2. Defective solenoid valve 2. Replace solenoid valve. is depressed. Little or no water 1. Limed-up heads or piping. 1. Delime heads. coming through the wash/rinse 2. Low water pressure. 2.Adjust pressure regulator(not supplied) or increase assemblies. pipe size to machine. Rinse water runs 1. Defective plunger in solenoid valve. 1. Replace. continuously with breaker 2. Defective diaphragm in solenoid valve. 2. Replace diaphragm. turned off. RECEIVED 10/10/2024 07610-004-37-38-P AWN BUILDING DEPARTMENT TROUBLESHOOTING TROUBLESHOOTING WARNING! Inspection, testing, and repair of electrical equipment should only be performed by qualified service Ipersonnel. Certain procedures in this section require electrical tests or measurements while power is applied WARNING to the machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect A/\ power, attach test equipment, and reapply power to test. When replacing electrical parts, disconnect power at source circuit breaker. OBSERVATION POSSIBLE CAUSE REMEDY Wash 1. Water level low. 1. Check water level. If low, run new fill cycle. temperature not at required 2. RTD setpoint too slow. 2. Check fault screen.Adjust wash temperature setpoint temperature range. 3. Defective RTD. 3. Replace. 4. Wash heater defective. 4. Replace heater element. 5. Defective heater contactor R1. 5. Replace. Rinse water 1. Incoming rinse water does not 1.Adjust as required. not at meet minimum criteria indicated on required machine data plate. 2. Replace if necessary. temperature range. 2. RTD is defective. 3. Check amperages. Replace if necessary. 3. Rinse heaters damaged. 4.Adjust rinse tank setpoint. 4. Setpoint screens set low. Machine 1. Drain clogged. 1. Remove obstruction. doesn't drain when POWER 2. Defective drain valve. 2. Replace. button is pressed. No indication of 1. Water turned off. 1. Turn water on. pressure. 2. Pressure gauge failure. 2. Replace pressure gauge. RECEIVED 10/10/2024 07610-004-37-38-P At BUILDING DEPARTMENT PARTS UH3O-FND CONTROL PANEL NOTICE Machines with serial numbers before Q 23D415452 have a different control panel. Click here to open earlier manual. LID irii!i . I/O MULE [r, ill 404) ® w I _ IId & G�� 0 0 © 0 Imo- ® O ®® o 20 Akki w ,! . Op, 21 0 .. ,_ 0 0 O OI:O 000 0004:1 0000 ®00 000 000 0000 0000 ih.a 1/.-4, / L2 - LI --� I wr r 1 I i t t 00 I'll 0 o Sm Gip Cil 'oft . e ri---.........11LL, -I.. 1. 1.iiik" 0 1� 0 0 0 ® 0 RECEIVED 10/10/2024 07610-004-37-38-P A$tiN BUILDING DEPARTMENT PARTS UH3O-FND CONTROL PANEL ITEM QTY DESCRIPTION PART NUMBER 1 2 Contactor, 30 A, 240 VAC 05945-002-74-20 2 1 I/O Module 06401-005-10-88 3 2 End Bracket, Terminal 05999-004-90-66 4 5 Separator, Terminal Block 05999-004-90-67 5 16 Terminal Block, Single Level 05999-004-90-68 6 16 Tag, Marking 05999-004-90-72 7 1 1 Power Supply 05950-004-81-79 8* 1 1 Peri-pump Assembly, 14 RPM 05700-002-72-48 9 1 Din Rail, 5 3/4" 05700-021-72-75 10 4 P-clamp, 1/4" ID 05975-002-61-42 11 1 Bushing, 1 1/8" 05975-210-08-00 12 1 Bracket, Control Panel 05700-004-96-19 13 4 Screw, 10-32 x 1/2" 05305-002-80-88 14 9 Fastener, 10-32 05340-111-58-10 15 1 Fuse, Time-delay 8 A, 250 V 05920-004-85-54 16 5 Nut, Plated 6-32 05340-118-04-00 17 3 Screw, 6-32 x 3/8" 05305-002-25-91 — 18 1 2 Screw, 10-32 x 1" 05305-002-19-42 19* 1 1 Peri-pump Assembly, 36 RPM 05700-003-78-74 20 2 Jumper Bars, 4-Pole 05999-004-41-80 21 2 Jumper Bars, 3-Pole 05999-004-90-71 22 1 Jumper Bars, 2-Pole 05999-004-41-79 23 1 Screw, 10-32 x 1/2" 05305-011-39-36 24 1 Decal, Ground 09905-011-86-86 25 1 1 Fuser Holder, One Only 05920-002-42-13 26 1 Relay, 10 A, 240 VAC 05945-111-89-75 27 6 Locknut, 10-24 Hex with Nylon Insert 05310-373-01-00 28 2 Screw, 6-32 x 1/2" 05305-004-23-63 29 2 Stiffener, Chemical Tube 05700-002-66-49 30 1 Chemical Port Assembly 05700-004-30-86 31 1 1 Tubing, Blue, 1/4" 04720-604-11-00 32 1 1 Tubing, Red, 1/4" 04720-601-12-00 33 1 1 Tubing, Clear, 1/8" 04720-111-58-09 *See UH3O-FND Chemical Feeder Pumps section for peri-pump components. RECEIVED 10/10/2024 07610-004-37-38-P MAN BUILDING DEPARTMENT 7= PARTS UL30 CONTROL PANEL 77 0 © © lI -' 4, grO te li§,1341 � rriA01V1 ridr.'' , y 00,40 f 0Ve �11 I :111;;;; o , tS `. \ lis • r,),), ,K.iii-lk .Til r.*;,- (a I0 b, r;elitap , 1v 0 O ITEM QTY DESCRIPTION PART NUMBER 1 2 Contactor, 110 V 05945-109-05-69 2 2 Relay, Omron 05945-002-47-41 3 3 Open/Closed Bushing 05975-003-35-21 4 1 Control Panel Weldment 05700-004-35-76 5 1 Universal Timer 05945-003-75-23 6 4 Screw, 10-32 x 1" 05305-002-19-42 7 1 1 Thermostat Plate 05700-004-37-67 8 1 Thermostat, Electric 06685-004-17-27 9 7 Screw, 10-32 x 3/8" 05305-173-12-00 RECEIVED 10/10/2024 07610-004-37-38-P AnN BUILDING DEPARTMENT PARTS UH3O-FND DISPLAY PANEL NOTICE Machines with serial numbers before 23D415452 have a different display CI fillpanel. Click here to open earlier manual. 4 O O 0 . Alimentar DETERGENT RINSE AID Alimentar ,-,� POWER Energia I Detergente PRIME PRIME Ayuda Enjuage \\_,%/ GEMMED 0 NORMAL 0VY. : H ACMEMEM HEAVY DELIME • Temperature de Enjuage Ddcil Descalcilicacion O 0 0 11111 CI CIO O 0 0 i 1 . .I ■ 0 Iwi It: 0. i ° ' t :1 ° 1 1 e \ O 0 0 ITEM QTY DESCRIPTION 1.11 PART NUMBER mll 1 1 Switch, Power 05930-004-85-60 2 1 Switch, Prime 05930-004-97-47 3 2 Display, LED 05945-004-85-61 4 1 Bracket, Display Panel 05700-005-07-33 5 1 Decal, Display Panel 09905-005-06-64 6 1 Switch, Cycle 05700-003-14-91 7 4 Locknut, 10-24 Hex with Nylon Insert 05310-373-01-00RErEI ED 8 1 Cable, Communication to Displays (Not Shown) 05999-004-99-35 I..66��II 10/10/2 24 07610-004-37-38-P AN BUILDING DEPARTMENT PARTS jidl1=11. UL30 DISPLAY PANEL 0 \ .------------------'''''Cl" 0 LII _,.,,ci ii/ ,. _ ,..... .......342 * 1,i, * 0I tli 0 �. IU►.Li�i 01 11 �I 0 o 0 1 0 * IIF m ITEM QTY DESCRIPTION PART NUMBER 1 11 Bracket, Control Panel 05700-004-37-73 2 1 Thermometer, 48" Rinse 06685-004-31-47 3 2 Light, Red 05945-504-07-18 4 3 Prime Switch 05930-011-49-54 5 2 Switch 05930-011-49-55 6 2 Light, Red 05945-111-44-45 7 11 Decal, Hi-Limit Ring 09905-004-37-89 8 1 Counter 05990-111-35-38 9 1 Light,Amber 05945-111-44-44 10 1 Light, Green 05945-111-44-43 11 1 Decal, Display Panel 09905-004-37-7 RECEIVED 10/10/2024 07610-004-37-38-P MAN BUILDING DEPARTMENT PARTSAllin TERMINAL BLOCK BOX 0 f%" 1111111111111.1:, .4 0 4440 10 4 4 4 Is e 1 0 -4, 0 0 • 0 ITEM QTY DESCRIPTION PART NUMBER Decal, Power Connections, UH30-FND 09905-011-62-72 1 1 Decal, Power Connections, UL30 09905-011-47-64 2 1 Terminal Block Box 05700-003-27-69 1 Terminal Box Cover(Not Shown) 05700-003-27-70 3 1 Decal, Copper Conductors 09905-011-47-35 4 2 Screw, 10-32 x 1/2" 05305-011-39-36 5 1 Ground Lug 05940-200-76-00 6 2 Terminal Block 05940-500-02-19 7 1 Locknut, 10-24 SS Hex with Nylon Insert 05310-373-01-00 8 1 Terminal Block Track 05700-000-43-6cRECEIVED 10/10/2024 07610-004-37-38-P ASIEN BUILDING DEPARTMENT PARTS UH3O-FND CHEMICAL FEEDER PUMPS NOTICE r � Machines with serial numbers before @' � 231418248 have different pumps. ItiI • �, m � l A .\ . (4k — 0 0 0 � iii 'On ' e4 c'c' in 10 to._ ll Os 0 I I #41 ‘ .�u8/ o o O 8 06 ° 0 I Amp-- 00, 00 4, 0 ,6),? ° ITEM I QTY DESCRIPTION PART NUMBER 1 2 Pump Housing 04320-111-37-09 2 4 Screw, 8-32 x 3/8" Phillips 05305-011-37-07 3 1 Roller, Plastic 04320-002-82-28 4 1 2 Pump Cover 04320-111-37-08 5 8 Screw, 6-32 x 3/4" Phillips 05305-011-37-05 6 4 Screw, 8-32 x 1/2" Phillips 05305-011-37-06 7 1 Tube, Squeeze, 8" 05700-003-22-89 8 1 Motor, 36 RPM 04320-111-47-47 9 1 Roller, Plastic 04320-111-65-27 10 1 Tube, Squeeze, 9" 05700-011-65-21 11 1 Motor, 14 RPM 04320-111-47-46 RECEIVED 10/10/2024 07610-004-37-38-P AOIN BUILDING DEPARTMENT PARTS AIL UL30 CHEMICAL FEEDER ASSEMBLY 0 4 0 it / '4( o 0 04c,i o , , ' \ tl* `\ `• ct, , �r m o o y 111 r ,.�.�1»jjb 11 rl. jkr ) 4' IV \ ITEM QTY DESCRIPTION PART NUMBER 1 1 Complete Peri-pump Assembly, 14 RPM* 05700-004-71-61 2 2 Complete Peri-pump Assembly, 36 RPM* 05700-004-71-60 3 1 Tubing, White, 1/4"x 48" 05700-002-62-13 4 1 Tubing, Blue, 1/4"x 48" 05700-002-62-11 5 1 Tubing, Red, 1/4"x 48" 05700-002-62-12 6 1 Tubing, White, 1/4"x 100" 05700-003-20-67 7 1 Tubing, Blue, 1/4" x 100" 05700-003-20-68 8 1 1 Tubing, Red, 1/4"x 100" 05700-003-03-45 9 1 Track Mount Assembly 05700-004-37-94 10 1 Peri-pump Channel 05700-003-53-25 *Components on next page. RECEIVED 10/10/2024 07610-004-37-38-P AS TN BUILDING DEPARTMENT PARTS AM UL30 CHEMICAL FEEDER PUMPS c ... ICI ,p L• i) . 0 ..§ 0 1,,.• ,, c4 r e. ttc) 00 , cc), 1 V 1-kt% ..; fil 1,14 )lk OT 0 ° • : wt ("--o ri 0 1..© 0 os, c4 I 00 4. 0OT J 4 ITEM QTY DESCRIPTION PART NUMBER 1 2 Pump Housing 04320-111-37-09 2 4 Screw, 8-32 x 3/8" Phillips 05305-011-37-07 3 1 Roller, Plastic 04320-002-82-28 4 2 Pump Cover 04320-111-37-08 5 8 Screw, 6-32 x 3/4" Phillips 05305-011-37-05 6 4 Screw, 8-32 x 1/2" Phillips 05305-011-37-06 7 1 Tube, Squeeze, 8" 05700-003-22-89 8 1 Motor, 14 RPM 04320-111-35-13 9 1 Motor, 36 RPM 04320-111-35-14 RECEIVED 10/10/2024 07610-004-37-38-P AMIN BUILDING DEPARTMENT PARTS Mii . UH3O-FND PLUMBING NOTICE ,�\ 5 Machines with serial numbers before 23D415452 have different plumbing. 4111) Click here to open earlier manual. \� 0 2 olio Q 41 ; CI 4 ii- a ,- , it ilo 0 m 0 4110 fli Ifs` 1 0 „..„ _ 2 Avk g . , 0 0 • 0 J�i -- ® 0 0 k G �0 0 i O© Vi-,a • ;' 0 GI 0 kto t , RECEIVED 10/10/2024 07610-004-37-38-P A$aN BUILDING DEPARTMENT PARTS UH3O-FND PLUMBING ITEM QTY DESCRIPTION PART NUMBER 1 1 Elbow, 1/2" 90-Degree 04730-206-08-00 2 2 Adapter, 1/2"x 1/2" 04730-004-97-23 3 1 Adapter, Male 04730-401-03-01 4 1 Tube, Copper 1/2"x 22" 05700-003-32-16 5 1 Vacuum Breaker 04820-003-06-13 6 2 Plug, 1/4" Brass 04730-209-01-00 7 1 Pipe Clamp 05700-011-38-62 8 1 Injector Adapter 05700-031-40-44 9 1 Check Valve 04820-111-51-14 10 1 Fitting, Outlet Elbow 04820-111-51-18 11 1 Nut, Tube 04730-011-59-45 12 1 Bushing, 1/4"x 1/8" 04730-003-05-61 13 1 1 Valve, 1/2" 208/60 04810-003-71-56 14 1 1 Hose Adapter 04720-004-24-68 15 1 Elbow, 1/2" 04730-406-31-01 16 1 Copper Tube 1/2"x 3" 05700-003-36-25 17 1 Union, 1/2" 04730-412-05-01 18 1 Elbow, 1/2" 90-Degree 04730-406-32-01 19 1 Tee, 1/2"x 1/2"x 1/4" Female 04730-411-25-01 20 1 Copper Pipe, 4 3/4" Long 05700-002-91-02 21 1 Adapter, 1/2" Male 04730-011-59-53 22 2 Rinse Hub Weldment 05700-021-38-31 23 2 Pipe Clamp (Side of Unit) 05700-000-35-05 24 1 Fitting, 1/2"x 1/4" 05700-004-36-74 25 11 1 Pressure Transducer 05945-004-84-32 26 1 Thermistor Probe, 4" 06685-004-34-58 NOTICE Use teflon tape on threads. Do NOT use"pipe dope." RECEIVED 10/10/2024 07610-004-37-38-P Agtt BUILDING DEPARTMENT PARTS All= UL30 PLUMBING •Lc 4.0 0 ‘* ® m 0 0 3 C 0 0 ® ° VI wanommoimil 0 0 0 / co CO 0 RECEIVED 0 0 10/10/2024 07610-004-37-38-P AWN BUILDING DEPARTMENT PARTS UL30 PLUMBING ITEM QTY DESCRIPTION PART NUMBER 1 1 Vacuum Breaker 04820-003-06-13 2 1 Elbow, 1/2" NPT x 3/4" Hose, 45-Degree 04730-003-29-22 3 1 Pipe Clamp 05700-011-38-62 4 2 Pipe Clamp (Side of Unit) 05700-000-35-05 5 1 Hose Union, 1/2" 04720-004-24-68 6 1 Male Adapter 04730-401-03-01 7 2 Elbow, 1/2" 04730-406-31-01 8 1 Copper Pipe, 1/2"x 1 3/8" 05700-004-69-44 9 1 Valve, 1/2" 04810-003-71-55 10 1 Copper Pipe, 1/2"x 6 1/2" 05700-002-60-71 11 1 Copper Pipe, 1/2"x 5 1/4" 05700-002-04-92 12 1 Elbow, 1/2", 45-Degree 04730-011-67-77 13 1 Copper Pipe, 1/2"x 25 1/2" 05700-011-59-85 14 1 Male Adapter 04730-011-59-53 15 1 Upper Manifold 05700-031-34-82 16 2 Rinse Plumbing Plate 05700-011-82-86 17 1 Rinse Plumbing Gasket 05330-111-42-81 18 1 Manifold 05700-002-13-75 19 1 Manifold Tube Position Bracket 05700-011-34-63 20 1 Lower Manifold 05700-021-52-80 21 1 0-ring 05330-002-60-69 22 1 Deflector Plate 05700-002-62-49 NOTICE Use teflon tape on threads. Do NOT use"pipe dope." RECEIVED 10/10/2024 07610-004-37-38-P AN BUILDING DEPARTMENT PARTS PLUMBING OPTIONS SHOCK ABSORBER (WATER ARRESTOR) OPTION r Water Arrestor, 1/2" 06685-100-05-00 "(L.ml.mnjilP 4 Tee, 1/2" x 1/2" x 1/2" Nipple, 1/2" NPT, Brass ��( 04730-211-27-00 04730-207-15-00 Water Arrestor Repair Kit (Plunger& 0-ring) 06401-003-06-23 PRESSURE REGULATING VALVE (PRV) OPTION • Pressure Regulating Valve, 1/2" 04820-100-04-07 iI r *t%e III L 1 0 SCALE PREVENTION SYSTEM (SPS) OPTION Replacement Cartridge (inspect at least every 6 months) r^404730 003 28 04 SPS System � Replacement Test Strip 04730-003-28-03 ill° � (Not Shown) 06401-003-28-06 NOTICE Must be installed vertically. The provided II bracket is secured to the wall. Observe proper inlet/outlet water directions(flow directions are molded into the top of the head).Line pressure should be released before changing cartridges.Machine should be delimed before installation. RE�;AEIVNE� I 10/10/20W24 07610-004-37-38-P BUILDING DEPARTMENT PARTS VACUUM BREAKER VACUUM BREAKER ASSEMBLY g Cap Screw 9 Data Plate—► D Cap Cap Retainer 0-Ring r 1 � Plunger Body ITEM QTY DESCRIPTION PART NUMBER 1 1 Components of Repair Kit 06401-003-06-23 Complete Vacuum Breaker Assembly 1/2" NPT 04820-003-06-13 RECEIVED 10/10/2024 07610-004-37-38-P AWN BUILDING DEPARTMENT PARTS WASH MANIFOLD u tiV 0 ro 0 See Motor& Pump Page O \ / 0 im� '' ,, 6mq i* 12 ! 01--4�s Ball Valve Assembly f :UH3O-FND �(!(�04730-003-33-64 ,. IrtUL30 �� S / 04730 003 34 60 t � I CO00, -,„2 : , f;0 0 0,..S. �1r�\1� O 0 VII I 0 . 0 RECEIVED 10/10/2024 07610-004-37-38-P AN BUILDING DEPARTMENT PARTS WASH MANIFOLD ITEM QTY DESCRIPTION PART NUMBER 1 1 1 Hub, Discharge Machine 05700-021-37-90 2 1 Gasket, Manifold 05330-200-23-00 3 1 1 Nut, Jam 1 1/2-12 05700-000-86-23 4 4 Hose Clamp, 1 5/16"-2 1/4"#28 04730-719-01-37 5 1 Hose, 1 1/4"x 2 1/4" Reinforced 05700-011-44-48 6 1 Hose, Bottom Manifold Pump 05700-001-22-92 7 3 Clamp, 3/16"to 1 1/2" 04730-719-06-09 8 1 Discharge Hose 05700-004-43-76 9 1 Hosebarb, 1"x 3/4" NPT Polypropylene 04730-011-65-86 10 1 1 Spacer, Drain Valve 05700-003-31-93 11 1 Bracket, Drain Valve Support 05700-004-35-85 12 1 Hose, 1" ID x 6' Long 04720-004-50-76 13 1 Hose-barb, 90-Degree 1"x 3/4" NPT 04730-011-65-87 RECEIVED 10/10/2024 07610-004-37-38-P AN BUILDING DEPARTMENT PARTS MOTOR & PUMP O ,,( , 1\ 1-- ) /o \ 1 Qi , ,i %r Q, J 4 ) 0 ( re IPA ,, /( (C.: u1� %fRic% ,-- 0 t iii;qiij Vil n 0 1 RECEIVED 10/10/2024 07610-004-37-38-P AN BUILDING DEPARTMENT PARTS MOTOR & PUMP Complete Pump& Motor Assembly 06105-004-35-22 ITEM QTY DESCRIPTION PART NUMBER 1 1 Pump Casing SS, 60 Hz 05700-002-85-00 2 1 Impeller, 60 Hz 05700-002-81-86 3 1 Mechanical Seal, 60 Hz 05330-002-34-22 1 Seal Plate, 60 Hz 05700-002-81-87 4 1 Case 0-ring, 60 Hz 05330-002-81-83 1 Drain Plug (Not Shown) 04730-002-81-89 5 1 1 Motor Only 06105-004-32-04 6 1 Shim Kit 05700-002-82-58 7 1 Case Capscrew 05305-356-04-00 2 Bolt, 3/8" 05305-276-03-00 8 2 Lock washer, 3/8" 05311-276-01-00 2 Nut Hex, 3/8-16 05310-276-01-00 9 1 1 Mounting Bracket 05700-003-31-58 RECEIVED 10/10/2024 07610-004-37-38-P Agt$N BUILDING DEPARTMENT PARTS RINSE ARMS & WASH ARMS Complete Wash Arm Assembly 1 per Unit on UH3O-FND 2 per Unit on UL30 05700-021-39-23 4114144 1 4.2 1 11 ft 1 4,...0 0 CO ITEM I QTY DESCRIPTION I PART NUMBER 1 1 I Wash Arm with End-cap 05700-021-46-58 2 1 Bearing,Assembly 05700-021-35-97 3 11 0-ring 05330-002-60-69 4 12 End-cap, Wash Arm 05700-003-31-59 RECEIVED 10/10/2024 07610-004-37-38-P AN BUILDING DEPARTMENT PARTS RINSE ARMS & WASH ARMS Complete Rinse Arm Assembly 0 2 per Unit on UH3O-FND 0 per Unit on UL30 CO, 05700-031-39-21 Rinse Arm Bearing Kit 06401-004-57-50 0 0 'uuiuuuuuuuuunuumnnnoaoaojjp°° , 0 ITEM QTY DESCRIPTION PART NUMBER 1 1 Retaining Ring 05340-112-01-11 2 1 0-ring (included in item #3) 05330-002-60-69 3 1 Bearing Assembly, Rinse Arm 05700-004-54-71 4 1 Rinse Arm 05700-031-38-30 5 2 End-cap, Rinse Arm 04730-111-60-41 RECEIVED 10/10/2024 07610-004-37-38-P Aga N BUILDING DEPARTMENT PARTS UH3O-FND RINSE TANK '-' T & 0 0 70 I1 12 11� 13 o _ O . O .,,,,4 * 0 ( I et?!gill , 0 .o * ......, /irlfic% i Complete Rinse Tank Assembly 0 r Vic,, . 05700-005-08-50 (Items 1-9) NOTICE Machines with serial numbers before 23D415452 have a different rinse tank. Click here to open earlier manual. ITEM QTY DESCRIPTION PART NUMBER 1 1 Heater, 8.2 kW, 230 V 04540-111-43-21 2 1 Gasket, Heater 05330-011-47-79 3 4 Lock Washer, 5/16" Split 05311-275-01-00 4 4 Nut, 5/16-18 SS Hex 05310-275-01-00 5 1 Fitting, 1/4" Imperial Brass 05310-924-02-05 6 9 Locknut, 1/4-20 SS Hex with Nylon Insert 05310-374-01-00 7 1 Rinse Tank Weldment 05700-005-08-49 8 1 Probe, High Water 06680-200-02-68 9 1 Locknut, 10/24-20 SS Hex with Nylon Insert 05310-373-01-00 10 1 Thermostat Bracket 05700-004-36-37 11 1 High Limit Thermostat 05930-004-33-15 12 1 Probe, Thermister 4" 06685-004-34-58 13 1 Cable, Temperature Probe 05700-004-33-23RECEIVED 10/10/2024 07610-004-37-38-P Agit N BUILDING DEPARTMENT PARTS UH3O—FND DOOR Complete Door Assembly 05700-005-07-44 0 NOTICE ,. © o Machines with serial numbers before O 23D415452 have a different door. Click �1 ' ' -'4111111111111111IN ° here to open earlier manual. © 1 o 0 OJ 0 , II:. 01: RI" 1 1 ,(11! 0 C ' 4:v14 0 (Dglk 10 I i ° .. 0 a m W0II 23 • ,a a m `\I 0 O © a 0 0 RECEIVED 10/10/2024 07610-004-37-38-P ATAN BUILDING DEPARTMENT PARTS UH3O-FND DOOR ITEM QTY DESCRIPTION I PART NUMBER 1 1 Outer Door Weldment 05700-005-07-43 2 2 Screw, 10-32 x 1/4" 05305-173-01-00 3 2 Bolt, 1/4-20 x 3/8" Hex 05305-274-20-00 4 2 Washer, SS 1/4-20 ID 05311-174-01-00 5 12 Fastener, 10-32 05340-111-58-10 6 1 Door Handle 05700-003-26-62 7 2 Stop, Door Hinge 05700-003-32-55 8 1 Hinge, Left 05700-003-32-71 9 1 Hinge, Right 05700-003-32-72 10 1 Inner Door 05700-003-33-21 11 1 Baffle, Door 05700-003-33-38 12 2 Hinge Spacer 05700-003-33-42 13 2 Retaining Plate 05700-011-44-37 14 1 Channel, Door Seal 05700-003-55-49 15 6 Screw, 1/4-20 x 1 1/2" Hex 05305-274-23-00 16 1 Gasket, Door L 05330-004-36-05 17 1 Gasket Clamp 05700-004-36-56 18 6 Pop Rivet, 1/8"x 3/8" 05320-003-06-98 19 12 Screw, 10-32 x 1/2" Pan Phillips Head 05305-002-32-37 20 2 Locknut, 10-32 with Nylon Insert 05310-373-02-00 21 1 Bracket, Door Magnet 05700-004-52-68 22 1 Magnet, Door 05930-002-88-42 23 2 Screw, 10-32 x 1/2" Pan Phillips Head 05305-011-44-52 RECEIVED 10/10/2024 07610-004-37-38-P A&N BUILDING DEPARTMENT PARTS UL30 DOOR 0 0 ® N©© 0 % 1 4 • m lik 0 s. , ‘ ,,,, ,,„, Ilt :, 4kairmil,,_-- "l'ims- ,,..„,(411 0 v e m 0 1 1 p All 0 / m ---- ,„,,, , ,, , ,._ . o g---- -: I o o 19 'r, 0 , �% �� 1 ° 0 0 12 Ihl , _1 0 14 m° 0 ,1 0 2 RECEIVED 10/10/2024 07610-004-37-38-P AN BUILDING DEPARTMENT PARTS UL30 DOOR ITEM QTY DESCRIPTION I PART NUMBER 1 1 Outer Door Weldment 05700-004-36-55 2 2 Screw, 10-32 x 1/4" 05305-173-01-00 3 2 Bolt, 1/4-20 x 3/8" Hex 05305-274-20-00 4 2 Nut, Lock 10-32 Hex with Nylon Insert 05310-373-02-00 5 2 Washer, SS 1/4-20 ID 05311-174-01-00 6 1 Bracket, Door Magnet 05700-004-52-68 7 1 Door Handle 05700-003-26-62 8 2 Stop, Door Hinge 05700-003-32-55 9 1 Hinge, Left 05700-003-32-71 10 1 Hinge, Right 05700-003-32-72 11 1 Inner Door 05700-003-33-21 12 14 Screw, 10-32 x 1/2" Pan Phillips Head 05305-011-44-52 13 1 Baffle, Door 05700-003-33-38 14 2 Hinge Spacer 05700-003-33-42 15 1 Switch Assembly 05700-003-34-80 16 2 Retaining Plate 05700-011-44-37 17 1 Magnet, Door 05930-002-88-42 18 1 Channel, Door Seal 05700-003-55-49 19 6 Screw, 1/4-20 x 1 1/2" Hex 05305-274-23-00 20 1 Gasket, Door L 05330-004-36-05 21 1 Gasket Clamp 05700-004-36-56 22 6 Pop Rivet, 1/8"x 3/8" 05320-003-06-98 RECEIVED 10/10/2024 07610-004-37-38-P AMEN BUILDING DEPARTMENT PARTS MISCELLANEOUS DOOR COMPONENTS S 0 UL30 it j1 ° ® 004 HIONO ° o� `7 1111 -41W V ci/iiiiiiiIiiiIiIii /IIIIIIIIIiIIIIII/IIIIIIIIIIIII/II/1 0 0 �/ 0 o t l• ' M \ N.,_ \ PI i \,,1.- I -- ,, ® 1 '2 • UH3O-FND L 0 1� l o RECEIVED 10/10/2024 07610-004-37-38-P AgeN BUILDING DEPARTMENT PARTS MISCELLANEOUS DOOR COMPONENTS ITEM QTY DESCRIPTION PART NUMBER 1 1 1 Switch Mounting Plate Assembly 05700-003-33-54 2 1 Door Spring 05700-003-32-85 3 11 1 Cover, Left Hinge Weldment 05700-004-36-80 4 1 Cover, Right Hinge Weldment 05700-004-36-81 Hinge Components secured with Locknut, 1/4-20 Hex with Nylon Insert 05310-374-01-00 5 2 0-ring 05330-003-32-34 6 1 Latch Spring 05700-003-32-32 7 2 Latch Nut 05700-003-32-33 2 Hardware: Locknut, 6-32 Hex with Nylon Insert 05310-373-03-00 8 2 Screw, 6-32 x 1/4" Flat Head 05305-171-01-00 9 1 Door Switch 05930-003-31-44 11 1 Door Switch Bracket 05700-003-31-43 10 1 Door Switch & Bracket Assembly 05700-003-32-21 11 1 Complete Switch Mount Assembly (UL30) 06401-004-47-76 12 1 Complete Switch Mount Assembly (UH3O-FND) 05700-005-07-45 RECEIVED 10/10/2024 07610-004-37-38-P ASZN BUILDING DEPARTMENT PARTS FRAME & PANEL COMPONENTS O 0 11 • V' 01 O s. ,N, ,, . I 0 0:0, • 1, ° N: 1 v " J.• . ►« O RECEIVED 10/10/2024 07610-004-37-38-P AWN BUILDING DEPARTMENT PARTS FRAME & PANEL COMPONENTS ITEM QTY DESCRIPTION PART NUMBER 1 1 Top Shroud Weldment 05700-003-37-06 2 1 Left Shroud Weldment 05700-003-37-04 3 1 Right Shroud Weldment 05700-004-36-82 4 1 Left Frame Weldment 05700-003-31-91 5 1 Swivel Feet 05340-108-02-00 1 Right Frame Weldment 05700-003-31-90 6 4 Hardware: Nut, 1/4-20 Serrated Hex 05310-959-03-00 4 Nut, 5/16-18 Cad Spine 05310-959-03-00 7 2 Bottom Strap 05700-003-92-20 8 1 Optional Back Panel 05700-003-33-55 9 1 Standard Back Panel 05700-004-36-83 10 2 Shroud Plug 05700-003-32-50 RECEIVED 10/10/2024 07610-004-37-38-P AffaN BUILDING DEPARTMENT PARTS MISCELLANEOUS PARTS Parts are not shown to scale in relation to each other. 0 ;yip 010 0 CO 4,';i9- ��e CO , �1 � e , 208-230 V Drain Water Tempering r / Kit Install Instructions ile❑ 0 A ITEM QTY DESCRIPTION PART NUMBER Components secured with Locknut, 1/4-20 SS Hex with Nylon Insert 05310-374-01-00 1 1 Rail, Left Rack 05700-031-37-89 2 1 Rail, Right Rack 05700-031-37-88 3 1 Splash Shield 05700-003-33-51 1 Strainer Spacer 05700-021-35-83 4 Attaches with: Nut, Nylon Wing, 1/4-20 05310-994-01-00 5 1 Strainer Weldment 05700-031-35-81 6 1 Drain Water Tempering Kit (UH3O-FND) 06401-004-61—R4- /E D 7 1 Switch, Horizontal Float(UL30) 06680-004-05- �/ 10/10/2024 07610-004-37-38-P AQN BUILDING DEPARTMENT PARTS STANDS & COMPONENTS 0 0 0 %44444 <:::!:::> rft. r 0 0 le 10 111 O 4-414* 6"Stand �! Install Instructions II— IIW ill o_ it h e 1ill r Il I1 Inv 0 0 'Cl 18"Stand 1! Install Instructions I- ❑— ❑— ITEM QTY DESCRIPTION PART NUMBER 1 1 6" Stand Assembly 05700-003-34-24 2 1 Stand 05700-002-88-82 3 4 6" Leg 05700-021-61-10 4 4 Bullet Foot 05340-108-01-03 5 1 18" Stand Assembly 05700-003-34-25 6 1 Stand 05700-002-88-82 7 4 Bullet Foot 05340-108-01-03 8 4 18" Leg 05700-002-89-47 9 4 Cross Brace 05700-003-25-90 10 4 Cross Member Bracket 04730 003 2�5 - rEIVED 10/10/2024 07610-004-37-38-P MAN BUILDING DEPARTMENT PARTS UL30 HEATER COMPONENTS dill '..0 %< .1 „... ... Ijfr ,...„ 4 ;1 ,. i •04. _ t tom(it\i4=i, 4 /i, 1f idp ‘of � OI I ,9 � IIIII rr 0 ." ,cam, I� �I ,- �o , %**-. , ..., , ...._, . . , (( ,.0- 9,, *4-; a 0 ,....,..,94' �I 1I'� 0 - k ITEM QTY DESCRIPTION PART NUMBER 1 1 Thermostat Bracket 05700 004 36 37 2 1 High Limit Thermostat 05930-004-33-15 3 1 Probe Bracket 05700-004-38-45 4 1 Wash Heater, 115 V, 1.5 kW 04540-004-33-76 5 4 Lockwasher, Split, 5/16" 05311-275-01-00 6 4 Nut, Hex 5/16-18 05310-275-01-00 7 1 Wash Heater Gasket 05330-011-61-34�ECEIVED 8 1 Thermostat, Electric Dual 06685-004-17-27 10/10/2024 07610-004-37-38-P AlaN BUILDING DEPAR T MEN" PARTS UL30 VACUUM SWITCH 0 I mow^ i1�� 0 Allo 4 Al rc © `,Aac O 0 0 0 0 . ,:., -. re ITEM QTY DESCRIPTION PART NUMBER Complete Assembly 05700-003-55-98 1 1 Box, Vacuum Switch 05700-003-55-96 2 2 Switch, Vacuum 06685-003-36-13 3 2 Wye, 1/4" Barbed PVDF 04730-003-36-14 4 6 Tubing, Clear 5/16" ID 04710-003-53-26 5 1 Tube, Red 1/4" OD x 100" Long 05700-003-03-45 6 1 Tube, White 1/4" OD x 100" Long 05700-003-03-45 7 1 Fitting, Liquidtite .231" x .394" Heyco 05700-003-20-67 8 2 Pressure Switch Bracket 05700-003-53-03 9 2 Spice, Blue Butt 05940-200-11-44 10 6 Locknut, 10-24 x 3/8" Phillips Truss 05945-602-01-16 11 14 Cable, 18 GA/5 Con 46" 05700-003-55-97 12 3 Tube Stiffener 05700-002-66-49 13 2 Splice, Red Butt 05940-200-26-00 RECEIVED 10/10/2024 07610-004-37-38-P Ala BUILDING DEPARTMENT UL30 VACUUM SWITCH INSTALL t Remove locknut on plumbing support bracket and mount 1. switch box over existing stud. Reinstall bracket and route red and white tubes behind blue hose as shown. Route gray cable down back and under the tub along inlet plumbing, remove wires from existing pressure switches, and �` connect to gray cable per instructions below. Detergent Switch (Red Tube) ' 1. Connect black wire from gray cable to black/yellow wire from switch. _wr ' 2. Connect brown wire from gray cable to blue wire from switch. Sanitizer Switch (White Tube) . 1. Connect white wire from gray cable to white/yellow wire from switch. 2. Connect red wire from gray cable to blue wire from switch. Back of machine showing use of existing mounting hardware for installation of vacuum switch assembly. 1 il .,-, 1 . Illt After cutting the existing red and white tube approximately 12" above the gray tube stiffener, insert the cut ends into the clear tubes as shown. ill MI RECEIVED 10/10/2024 07610-004-37-38-P A4N BUILDING DEPARTMENT SCHEMATICS UH30-FND NOTICE Machines with serial UH3O-FND numbers before 23D415452 SCHEMATIC have a different schematic. GND CO L2 Click to open earlier GRN ° 208/230 VOLTS, 50/60 Hz, 1-PHASE c manual. H1 10 GA DLK LIO I11(-D. 10 GA BLK fl El H El El El n I0 GA RED TO II 02 10 GA RED RINSE HEATER Z 14 GA BLK C Ij a BLK M1 WHT TO II 62 14 GA RED WASH MOTOR 6l (F1 FUSE WHT/BLK HI PS H4 RED • • 18 GA BLK 24VDC 24VDC- 18 GA GRY/BLK RED/BLK lyl POWER, CYCLE pI5_2 P15_1 TO P5-3 TO PUMP- 2 AND PRIME _DISPLAYS °B2 0 INT.POWER 0 SWITCHES SUPPLY 24 VDC 24 VDC I/O MODULE WHT/BLK Sl�l WHT/YEL 1 R4 2 CONTROL/DOOR )TO P14 II RS-232 PJ HLRS ° POWER P1-1 OKII 0 131-2 WHT/BLK ERG/BLK e0e RINSE HEAT CTR RINSE HEATER PI-3 0 I PI-4 ERG P2-1 03 I I P2-2 P2-3 di I I P2-4 P3-1 015 I 0 P3-2 )FROM R4-4 K6I BLK/YEL WASH PUMP P3 3 0 II 0 P3-4 VIE FILL SOL P4 I 0 II 0 P4-2 BLU VIE .CD. WASH PUMP CTR DRAIN OPEN P4-3 KB P4-4 GRN/WHT o id BLU 0+0_RINSE/FILL SOL DRAIN CLOSE P5-I 091 I 0 P5-2 GRN P5-3 K10 P5-4 WHT/BRN L2) AL E DETERGENT PUMP O 0 LI) BLK 2 J1 DRAIN<OPTIONUENCH CONN RINSE AID PUMP P6-I oll I 0 P6-2 WHT/BLU II_ GRN/WHT 3 J )GRAY/BLK 24VDC~ CYCLE START LED P6-3 o II I P6 4 SPL M3 SPL FROM POWER SUPPLY 0 BLK WHT O DRAIN MOTOR r WHT P8 LLC PROBE GRN GRN/YEL ri RING L GND J SP r[BUTTON CONNECTORC PT O O P9 LINE PRESSURE R4•6 M4 TTT WHT/BRN RED/WHT C74 DETERGENT PUMP -g D P10 WASH TEMP TO P3-3 I/ RED/WHT GRY/BLU BLK/YEL PI1 RINSE TEMP GRY/BLU WHT/BLU RINSE AID PUMP YELLOW RED/BLUPIe BOOSTER TEMPVIOLET RED/BLU0 GRY/YEL 70„.„37±K D RED/BLKCK SBf P13 P14 FROM PS 24V➢C<N 15 14 I3 I2 I1 ' 10 0 0 0 Q1 GRY/YEL 0 CYCLE START LED secgsTega cN JACKETEDWYEL( CORD FROMHT/SI GRAM 1 GRY/RE➢ DRAIN QUENCH KIT (OPTION) EMPTY GRY/BLII EMPTY EMPTY a OUT TRIG EMPTY EMPTY J ® iris L1 Cannecnon Diagram for 10 Module PLUG (MATES W/Jl> SOLENOID DELAY-OFF � • MER .11.11.1.11 MRlNr Ta TS Is TI I3 11E PIS M e LEGEND /un•. s S IS)'U_-s1ls. vccour RC pings(4 it LI Q T T T47GE AW.lOG Door MP L1,L2 POWER DISTRIBUTION BLOCK it O Hvb1�rr a QU GND EARTH GROUND 11 UM 4 'LOOIEITPWM Pre El CYCLE SWITCH LED CO KOea.RIne "s 9 D.e s D IC RTM Al HEATER, RINSE ��4�_ U R'I Ml MOTOR, WASH PUMP ' N Yo[our/as-13) �----� M3 MOTOR, DRAIN j 8 !I Qa� �4 �� ti M4 MOTOR, DETERGENT PUMP �,+_j,���K1 RV® m Rtg'DC RPM M5 MOTOR, RINSE AID PUMP s'r-oo'r'Ym r r ® GRN a 0 RED IH24VOC) Rl CONTACTOR, RINSE HEATER K)RII a3 N N5 RS ND KS1 N3 EGO 11N2 DLgID m WMT R3 CONTACTOR, WASH PUMP Pi 12 PI N PE Me R4 RELAY, CONTROL MM1 MIRE PAb13 / Fl FUSE- Ll CONTROL DE W D G 8 Si SWITCH, DOOR IntARCOnne tERbleiA L e N L R L S2 SWITCH, CYCLE START 3 twisted s3p.m ROT R N R HLRS HIGH-LIMITILT-STAY, RINSE HEATER RE�'EIVE� 3ten9 pnrs RFS RINSE/FILL SOLENOID 0 ® 5 d© PT PRESSURE TRANSDUCER Connectors shown in top PS POWER SUPPLY 24VDC Elv.(wire.mte.ton end) CO RRESPONDINGcONNECIOR Jl CONNECTOR, DRAIN QUENCH (OPTION) 09905-TAS-10-26-0 GOING TO DISPLAY PCB SPL SPLICE 10/10/2024 07610-004-37-38-P AWN BUILDING DEPARTMENT SCHEMATICS I UL30 UL30 SCHEMATIC 115 VOLTS, 50/60 Hz, 1-PHASE GND LI N • 0 Ml _i_ R1� RI BLK L1 ' TI BLK 1 WHT O II�2 WHT • m Ell_ R2 R2 BLK • Ili BLK BLK , n n n n n n WHT O I I O WHT• LI TIrL T2 L2 BLU BLU J WHT/RED WHT/RED ? L1 L2• • le BLU r OPTIONAL P�HLK/WHT BLK/WHTTS I ORG/YE R3 ORG R4 —I FL RED HL•WHT/GRN•®• WHT/RED. o O O o O I I O 'O O RE� cr.,• • •WHT/BLU•�• WHT/RED• L AB J • • BLU • BLU 0WHT/RED• BLK Q10 BLU/WHT • BLU/WHT TM WHT/RED• qDl ^ S9 A B BRN BRN O BLK WHT/YE WHT/RED• S2 VID ES WHT/RED D 1 R3 NC ` BRN • RED �0 WHT BLK/YEL• •OWHT/RED• BLK • I GRY/WHT S4 ORG �O 4 6 • O •04 HT/RED S3 V� N0 • L E G E N D BLK WHT WHT •- • WHT/RED. Cl CYCLE/RESET MICRUSWITCH BLU •C2 OFF/DRAIN MICROSWITCH [ r K/ORG Ra WHT/RED♦J 1 C3 WASH MICRUSWITCH L C4 DRAIN MICROSWITCH C NC S4 0 CS FILL MICROSWITCH BRN C2 BLK/ORG E2 WHT/RED C6 SANITIZER MICROSWITCH 0 BLU/WHT • C7 DETERGENT MICRUSWITCH L.) BLU/WHT C8 RINSE AID MICROSWITCH rRa El POWER LIGHT BLU/YEL' YEL/BLK' NC c E2 CYCLE LIGHT a� 6__ a VIO/WHT VIO/WHT Rl WHT/RED• E3 FILL LIGHT OPTIONAL •• ORG ,e A B E4 HI LIMIT LIGHT (OPTIONAL) E5 DETERGENT LIGHT NC E6 SANITIZER LIGHT NOTE ORG C Q GRN/WHT • BLK GI) WHT/RED FS FILL SOLENOID WITH OPTION OMITTED, 0 YEL/VHT . GRN • FL FLOAT (OPTIONAL) BLU/YEL WIRE NO 77 CT Hl WASH HEATER (OPTIONAL) CONNECTS TO C3-NC. RED/WHT 10000001 WHT/RED. HL WASH HEATER OVERLOAD (OPTIONAL) NC Ml WASH PUMP MOTOR CRED/WHT n •RED/WHT 0 WHT/RED• BLU/WHT M2 DRAIN MOTOR • O NO o S M3 SANITIZER PUMP MOTOR 0'1 .7 WHT/RED• M4 DETERGENT PUMP MOTOR /" M5 RINSE AID PUMP MOTOR NC M3 BRN/WHT WHT/RED R1 WASH MOTOR CONTACTOR • R2 WASH HEATER CONTACTOR (OPTIONAL) • BLU/WHT c6 R3 CONTROL RELAY 0 •BLU O 6 R4 WASH HEATER RELAY (OPTIONAL) NO S1 POWER SWITCH D S2 CYCLE SWITCH BLU/WHT C NC BLK/WHT WHT/RED • S3 DOOR SWITCH • 0 C7 S4 WASH/DELIME SWITCH 0 •BLU O� S6 SANITIZER PRIME SWITCH S7 DETERGENT PRIME SWITCH N� ORG/WHT • MS WHT/RED S8 RINSE AID PRIME SWITCH BLU/WHT cB S9 DETERGENT VACUUM SWITCH 0 S8 S10 SANITIZER VACUUM SWITCH NO BLU Cr--- TM TIMER MOTOR D TS THERMOSTAT TIMING CHART 10 20 30 40 50 60 70 80 90 100 110 120 YCLE N.C.11 BI C 1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 ElOFF N.0.IIIR III 1111111111111111111111111111111111111111 DRAIN N.C......J111111111111111111111111111111111111111111111111111111111111111111111111 111 WASH N.OIII. I 11111111 N.C._..J111111 111111111111111111111111111111111111111111111111111111111111111111........111111111111111111111111111111111111 m DRAIN N'O. 1111111111111111". N.C•IIIIIIIIII11111111111111111111111111111111111111111111111111 11111111111111111111111111111111111111111111 El FILL N'O. 11111111 N.C.IIIIIIIIII 11111111111111111111111111111111111111111111111111111111111111111........1111111111111111111111111111111111111 m SANIT. NO. 1111111 N.C.II111111II 111111111111111111111111111111111111111111111111111111111111111111111. 1111111111111111111111111111111111 El DET. 0 111111111111 N.C.111111.... II 1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 mRINSE N.O. 1111111 AID N.C.IIIIIIIIII111111111111111111111111111111111111111111111111111111111111111111111. 1111111111111111111111111111111111 09905-004-39-51 REV K RECEIVED 10/10/2024 07610-004-37-38-P AMN BUILDING DEPARTMENT SCHEMATICS UH3O-FND DISPLAY WIRING of DISPLAY DISPLAY CYCLE BUTTON ili/lliliin ,C)/ 4 ' 1/54,4 , / liMMM, killil IAi ._in PRIME POWER l� BUTTON BUTTON \ / I' \ RECEIVED 10/10/2024 07610-004-37-38-P ASZN BUILDING DEPARTMENT RECEIVED 10/10/2024 ASPEN BUILDING DEPARTMENT NOBLE UNDERCOUNTER DISHMACHINES 1,NDBILE WARE WASH ING Noble Warewashing•Lancaster, Pennsylvania www.nobleproducts.biz For Service Call 1-888-800-5672 RECEIVED Noble UH30-FND/UL30 Manual •07610-004-37-38-P ►24 ASPEN BUILDING DEPARTMENT