Loading...
HomeMy WebLinkAboutFile Documents.433 E Hyman Ave.0041-2024-BCOM (4) Allrf � � Clear Environmental LI I V G 128o Buffalo Grass Pl. Elizabeth, CO 80107 1720-982-1513 Asbestos Inspection and Sampling Report 433 E. Hyman Ave. Aspen, Co 81611 Prepared for: Rag&Bone Industries LLC Attn: Carmina 425 West 13th St. New York, Ny 10014 Performed&Prepared by: Josh Berard All Clear Environmental Consulting 128o Buffalo Grass Pl. Elizabeth, Co 80107 (720) 982-1513 Project Number: B.I - 1562 Inspection Date:August 14th, 2024 RECEIVED 10/10/2024 ASPEN BUILDING DEPARTMENT Table of Contents Inspection Overview Introduction I Site Description II Scope of Work III Sampling and Analytical Procedures IV IV (a) Sampling Procedure IV (b) Analytical Procedure Inspection Protocol V Homogenous Areas VI VI (a) Classifications of Materials VI (b) Friable Material VI (c) Material Conditions VI (d) Sample Quantities Result Overview VII Photos VIII Laboratory Results IX Conclusion/Recommendations X Limitations XI Certifications XII RECEWED 2 10/10/2024 ASPEN BUILDING DEPARTMENT I. INTRODUCTION On August 14th, 2024 Mr. Josh Berard with All Clear Environmental Consulting conducted an asbestos inspection and collected asbestos bulk-samples of suspect asbestos-containing materials (ACM) within the of the building located at 433 E. Hyman Ave. The purpose of the inspection was to identify and sample potentially hazardous friable and non-friable ACM within the structure that would be impacted. Mr. Berard is Accredited by the Environmental Protection Agency(EPA) and certified by the Colorado Department of Public Health and Environment (CDPHE) as an Asbestos Building Inspector. A copy of his accreditations and certifications can be found in section XI of this report. II. SITE DESCRIPTION The one structure is a commercial retail store III. SCOPE OF WORK Carmina De Dios retained All Clear Environmental to conduct an asbestos inspection regarding suspect asbestos containing material that holds reservations of being disturbed during renovation of interior. The asbestos inspection conducted on August 14th, 2024 constituted a limited inspection and fulfills the asbestos inspection requirements for structures that are to be renovated. IV.SAMPLING&ANALYTICAL PROCEDURES (a) Sampling Procedures: Random bulk-samples representative of the suspect ACM of each homogeneous area were collected according to the guidelines published as EPA Final Rule: Title II of the Toxic Substances Control Act(TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763 and CDPHE Regulation Number 8, Part B -Asbestos (Reg. 8). All Clear Environmental has collected the appropriate number of bulk-samples to meet all regulatory requirements for the classification and quantity of each homogeneous area. Note some minor d r t' sampling was conducted. CMED 3 10/10/2024 ASPEN BUILDING DEPARTMENT (b)Analytical Procedures: Bulk samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116,July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. All bulk-samples were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory using the Polarized Light Microscopy(PLM) method for asbestos content (see X for laboratory report). V. INSPECTION PROTOCOL The asbestos inspection was conducted by an Environmental Protection Agency(EPA) and CDPHE certified Building Inspector. The inspection procedures included identifying and sampling suspect ACM within pre-defined areas. Suspect materials alike in appearance and application were sampled as HAs. After identifying the appropriate suspect ACM, with the use of a random number generator, random samples of suspect drywall &brick mortar building material were taken throughout interior and sent to an NVLAP accredited laboratory for analysis. See lab results in section IX VI. HOMOGENOUS AREAS (a) Suspect materials are divided into three classifications: 1. Thermal systems insulation (TSI): any type of duct, boiler, tank, or pipe insulation. 2. Surfacing material (SM): sprayed or troweled onto structural building member. 3. Miscellaneous (Misc.): other suspect materials ie. flooring, ceiling tiles, insulation, and finishing materials. (b) Friable material is one that, when dry, can be pulverized, or reduced to powder by hand pressure, a non-friable material cannot.A non-friable material may become friable if its condition had deteriorated or has been impacted by forces that have rendered it friable. (c) The three categories in which sampled materials are placed are as follows: Good: None to very little visible damage or deterioration RECEIVED 4 10/10/2024 ASPEN BUILDING DEPARTMENT Damaged: The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the damage is evenly distributed, or one-quarter if the damage is localized Significantly Damaged: The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over greater than io% of the surface if the damage is evenly distributed, or %25 if the damage is localized (d) All Clear Environmental collected at least the minimum number of samples from each homogeneous area necessary to meet all regulatory requirements for the quantity of material to be disturbed. The quantities listed in this report are approximate and on-site verification of the exact quantity of each material is required. The following outlines the minimum sample quantities required per homogeneous area: Thermal System Insulation (TSI): Each homogeneous area requires a minimum of three (3) samples; at least one (1) sample must be collected from each patch; and collect enough samples sufficient to adequately assess the material and determine the asbestos content for TSI fittings such as pipe elbows or "T's". Surfacing Materials (SM): up to l,000 ft2 of material requires a minimum of three (3) samples; between i,000 ft2 and 5,00o ft2 of material requires a minimum of five (5) samples; over 5,00o ft2 of material requires a minimum of seven (7) samples; one (1) sample of each patch Miscellaneous Materials (Misc.): collect enough samples sufficient to determine the asbestos content A Homogenous Area (HA) is defined by material that is uniform in appearance, texture, color and date of application. Once the homogeneous area is determined, the inspector will choose the appropriate number of samples to take in accordance with EPA and CDHPE. (HA) 1. Drywall/Texture 0 Throughout 2. Joint Compound 0 Throughout 3. Brick Mortar 0 Separator Wall &North Wall RECEIVED 5 10/10/2024 ASPEN BUILDING DEPARTMENT VII. RESULTS Asbestos was NOT reported within ALL bulk-samples collected and analyzed.All Clear Environmental collected a total of nine (9) asbestos bulk-samples of three (3)homogeneous areas. The following are the suspect asbestos-containing materials that were collected and their respective asbestos content: Material Asbestos Content All Materials Determined to be Non-Detect ND The following table describes the materials composing each homogeneous area as well as the locations of each bulk-sample collected.Also listed is the classification,condition,friability and estimated quantity of material to be removed and/or disturbed,as well as the asbestos content within each bulk-sample.Please see section IX for a breakdown of each bulk sample. RECEIVED 6 10/10/2024 ASPEN BUILDING DEPARTMENT Asbestos Bulk Sampling Log H.A Sample Material Friable I.D T e Sample Location Condition (Y/N) ACM Type Quantity yP Bath Rm-E. Wall Left of H-1 -of Jamb Bottom Middle ND Dressing Rm 1 -N. Wall O2 Bottom Middle ND Dressing Rm Foyer- W. Wall 03 SM Bottom Middle Good Y ND Approx.1,60o Sq.Ft. 04 Dressing Rm 2-S. Wall ND Bottom Right o MainRm-N. WallW.End ND 5 Bottom H-2- 01 Bath Rm-S.E Corner Wall ND Middle 2 MM Good Y - Approx.75 Sq.Ft. Dressing Rm 2-S.E Corner 02 Wall Bottom ND H- 01 Divider Wall- W.Side Jamb ND 3 Face 3 MM Good N Approx.55o Sq.Ft. Dressing Rm 2-N. Wall 02 Middle Right ND SM-Surfacing Material MM-Miscellaneous Material ND-Non Detect RECEIVED 10/10/2024 ASPEN BUILDING DEPARTMENT VIII. Photos • t. }fit *Mir .3'01 16. A lk 14 -02 N 2 of .e RECEIVED 10/10/2024 ASPEN BUILDING DEPARTMENT H-1-04 Bath p,R 1 D R ? H- 1.05 H-2.01 H-1-02 H-3-02 .H-1.01 _ N-2-02 H-3-01 H-1-03 W S N E Sample Layout RECEIVED 9 10/10/2024 ASPEN BUILDING DEPARTMENT IX. Laboratory Results ANALYTICAL REPORT Prepared for: All Clear Environmental Consulting 1280 Buffalo Grass Place Elizabeth, CO Project: Rag n Bone B.I Order No.: 0042613 Report Date: 08/16/2024 Atlas Technical Consultants LLC Page 1 of 7 14 Inverness Drive East,Building B Suite132,Englewood,CO 80112 Phone 1-303-799-6100 Fax 1-303-799-3441 www.oneatlas.com RECEIVED 10 10/10/2024 ASPEN BUILDING DEPARTMENT T ■ C► BATCH NO. �r 0042613 PLM REPORT SUMMARY NVLAP Lab Code 102031-0 Customer: Josh Berard Atlas Job No.: All Clear Environmental Consulting Batch No.: 0042613 1280 Buffalo Grass Place Report Date: 08/16/2024 Elizabeth, CO Sample Date: 08/15/2024 Project: Rag n Bone B.I Date Analyzed: 08/16/2024 Customer Project No.: 1561 Identification: N/A Test Method: EPA 600/R-93/116,40 CFR, Part 763,Appendix E to Subpart E July 1993 Client No. Lab No. Sample Description/Location Asbestos Content H-1-01 0042613-001 LAYER 1 None Detected Paint/Texture,White/White,24°C Note:Layer is mainly Paint H-1-01 0042613-001 LAYER 2 None Detected Drywall,Brown/Grey,24°C H-1-02 0042613-002 Paint/Texture,White/White,24°C None Detected Note:No Drywall Present H-1-03 0042613-003 Paint/Texture,White/White,24°C None Detected Note:No Drywall Present H-1-04 0042613-004 LAYER 1 None Detected Paint/Texture,White/White,24°C Note:Layer is mainly Paint H-1-04 0042613-004 LAYER 2 None Detected Drywall,Brown/Grey,24°C H-1-05 0042613-005 LAYER 1 None Detected Paint/Texture,White/White,24°C Note:Layer is mainly Paint H-1-05 0042613-005 LAYER 2 None Detected Drywall,Brown/Grey,24°C H-2-01 0042613-006 LAYER 1 None Detected Paint/Joint Compound,White/White,24°C Atlas COPhone Consultants LLC EIVED 14 Inverness Drive East,Building B Suite132,Englewood,C 80112 Phone 1-303-799-6100 Fax 1-303-799-3441 www.onea REC 11 10/10/2024 ASPEN BUILDING DEPARTMENT T ■ A e' BATCH NO. rT �� 0042613 PLM REPORT SUMMARY NVLAP Lab Code 102031-0 Customer: Josh Berard Atlas Job No.: All Clear Environmental Consulting Batch No.: 0042613 1280 Buffalo Grass Place Report Date: 08/16/2024 Elizabeth, CO Sample Date: 08/15/2024 Project: Rag n Bone B.I Date Analyzed: 08/16/2024 Customer Project No.: 1561 Identification: N/A Test Method: EPA 600/R-93/116,40 CFR, Part 763,Appendix E to Subpart E July 1993 Client No. Lab No. Sample Description/Location Asbestos Content H-2-01 0042613-006 LAYER 2 None Detected Drywall Tape,Off White,24°C H-2-01 0042613-006 LAYER 3 None Detected Joint Compound,White,24°C H-2-01 0042613-006 LAYER 4 None Detected Drywall,Brown/Grey,24°C H-2-02 0042613-007 LAYER 1 None Detected Paint/Joint Compound,White/White,24°C H-2-02 0042613-007 LAYER 2 None Detected Drywall Tape,Off White,24°C H-2-02 0042613-007 LAYER 3 None Detected Joint Compound,White,24°C H-2-02 0042613-007 LAYER 4 None Detected Drywall,Brown/Grey,24°C H-3-01 0042613-008 Mortar,Dk.Grey,24°C None Detected H-3-02 0042613-009 Mortar,Grey,24°C None Detected These samples were analyzed by layers.Specific layer or component asbestos content is indicated when relevant.Unless requested by Client,building material manufactured with multiple layers are reported as a single sample.The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation(CVAE).EPA regulations also indicate that Regulated Asbestos Containing Materials(RACM)--materials which are friable or may become friable--be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE.Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested.The results may not be reproduced except in full,and should not be used as a scope of work for abatement without consulting with Atlas Technical. Atlas COPhone Consultants LLC .WEL) 14 Inverness Drive East,Building B Suite132,Englewood,C 80112 Phone 1-303-799-6100 Fax 1-303-799-3441 www.onea ��► 12 10/10/2024 ASPEN BUILDING DEPARTMENT T ■ A C► BATCH NO. �r �1 0042613 PLM REPORT APPROVAL NVLAP Lab Code 102031-0 Customer: Josh Berard Atlas Job No.: All Clear Environmental Consulting Batch No.: 0042613 1280 Buffalo Grass Place Report Date: 08/16/2024 Elizabeth, CO Sample Date: 08/15/2024 Project: Rag n Bone B.I Date Analyzed: 08/16/2024 Customer Project No.: 1561 Identification: N/A Test Method: EPA 600/R-93/116,40 CFR, Part 763,Appendix E to Subpart E July 1993 PLM Analysis Methodology PLM samples were analyzed utilizing the Environmental Protection Agency's Test Method: Method for the Determination of Asbestos in Building Materials(EPA 600/R-93/116.July, 1993)40 CFR, Part 763,Appendix E to Subpart E. Reporting Limit<1%Asbestos. Additional treatment and tests may be required to accurately define composition(i.e.ashing,extractions, acetone treatment,and TEM). Unused portions of samples are archived for one year unless client requests special handling. Samples not taken by laboratory personnel. Laboratory Equipment Laboratory analysis was accomplished utilizing an Olympus BH-2 polarized light microscope.The microscope is equipped with dispersion staining lenses. Quality Control Atlas Technical Consultants LLC is accredited by NVLAP Bulk Asbestos Sample Quality Assurance Program(Lab Code 102031-0).Atlas participates in the NVLAP Bulk Asbestos Sample Quality Assurance Program and maintains an in-house QC/QA program for bulk samples whereby 10%of all submitted samples are reanalyzed and documented in a Quality Control Manual. Atlas also participates in a quarterly round robin QC/QA program for bulk samples with several accredited laboratories throughout the United States. Laboratory Personnel Samples were analyzed by Hailey Hopkins,Laboratory Analyst.Ms.Hopkins has a degree in Ecosystems Science and Sustainability and has successfully completed Atlas Technical Consultants In-House Training Program. bievainityApproved Signatory: w,_DA# Hailey Hopk TESTING NVLAP LAB CODE 102031-0 The non-detection of asbestos fibers in floor tile by PLM is of itself inconclusive.Confirmation by Transmission Electron Microscope(TEM)is recommended for negative floor tile samples. This report must not be used by the client to claim product endorsements by NVLAP or an agency of the U.S.government. This test reports only to the items stated.This report is confidential to customer. Results are not published on a public domain. Atlas COPhone Consultants LLC IVED 14 Inverness Drive East,Building B Suite132,Englewood,C 80112 Phone 1-303-799-6100 Fax 1-303-799-3441 www.onea RET:0E 13 10/10/2024 ASPEN BUILDING DEPARTMENT y26t3 -r T ' e, _ ---.....immunim 1 rrnMwnd. J i.s. 21 1m•• ..ti••• n Ilex if Mt f r•ecoryrl memo A1II Close Iwimire•YI J hrMl Name Rag•beer O 1 &Memo MO O•lldln limn M C•ietlss Aft 1.14 1 Mamas _CieL.re i4 i t n 1% i - - Mte+e?u (7)31101-I,a1 Caiwlw AYess 40 llro An i t cameo best Phowd %podia Il.ur•c7Yre: Laud: iesisitAllt l...0 Aim I>feeeAr[1/reCless ♦ ` Smirk 14B•Z s _ Sample Mood in*,L-oomis 1 11-lal 1W ' 03 • ` N • •3 l • • IIIFFF�YYir , C 11 • 12- l , 1 14 17 i tt 11 1 21 ' 1.4 • • A. M•.4•Nr•.•••••••b mm4 44,411•44wa•.or�4/.........•.qr••♦•0444"w r 444044044.04044/11.rlrMP r IMM•imp 44.44.44.4.r_r 1,41.4411411 S'L%N OE(TI STODZ Rsie spoek.j Ni Herr _ Tim �. N�� MSc te.. -.----.•- - 11134 Roo •"� �/ 0 - .1-21!' e.�.L • ' ��.. ..... �:' - v 1 1 t letrrrn•••Drew V.A.! F1_.itore h &Al L . Keg.. ad CO 80112 Ph. aO3241kt1N.• temrai Ilia Limn RECEIVED 14 10/10/2024 ASPEN BUILDING DEPARTMENT T ■ e' BATCH NO. rT �� 0042613 PLM REPORT RESULTS NVLAP Lab Code 102031-0 Customer: Josh Berard Customer Project No.: 1561 All Clear Environmental Consulting Description: Rag n Bone B.I 1280 Buffalo Grass Place Date Received: 08/15/2024 Elizabeth, CO Date Analyzed: 08/16/2024 Date Reported: 08/16/2024 Collected: 08/15/2024 Comments: Collected By: Josh Berard Collection Address: 433 Hyman Ave Asbestos Non-Asbestos Lab ID Sample Location/ Constituents Constituents Sample# Sample Description (%) (%) 0042613-001 None Detected Cellulose Fiber(Incom) 15% H-1-01 LAYER 1 Carbonates 10% Paint/Texture,White/White,24°C Aggregate 8% Note:Layer is mainly Paint Non-Fibrous Material 67% None Detected Cellulose Fiber(Incom) 40% Fibrous Glass(ISO) <1% LAYER 2 Gypsum 60% Drywall,Brown/Grey,24°C 0042613-002 None Detected Cellulose Fiber(Incom) 2% H-1-02 Paint/Texture,White/White,24°C Carbonates 65% Note:No Drywall Present Aggregate 15% Perlite 5% Binder/Filler 13% 0042613-003 None Detected Cellulose Fiber(Incom) 5% H-1-03 Paint/Texture,White/White,24°C Carbonates 60% Note:No Drywall Present Aggregate 10% Perlite 5% Binder/Filler 20% 0042613-004 None Detected Cellulose Fiber(Incom) 15% H-1-04 LAYER 1 Carbonates 10% Paint/Texture,White/White,24°C Aggregate 8% Note:Layer is mainly Paint Non-Fibrous Material 67% None Detected Cellulose Fiber(Incom) 40% Fibrous Glass(ISO) <1% LAYER 2 Gypsum 60% Drywall,Brown/Grey,24°C 0042613-005 None Detected Cellulose Fiber(Incom) 15% H-1-05 LAYER 1 Carbonates 25% Paint/Texture,White/White,24°C Aggregate 10% Note:Layer is mainly Paint Non-Fibrous Material 50% None Detected Cellulose Fiber(Incom) 40% Fibrous Glass(ISO) <1% LAYER 2 Gypsum 60% Drywall,Brown/Grey,24°C Atlas COPhone Consultants LLC EIVEn 14 Inverness Drive East,Building B Suite132,Englewood,C 80112 Phone 1-303-799-6100 Fax 1-303-799-3441 www.onea ��► 15 10/10/2024 ASPEN BUILDING DEPARTMENT T ■ A C► BATCH NO. 0042613 PLM REPORT RESULTS NVLAP Lab Code 102031-0 Customer: Josh Berard Customer Project No.: 1561 All Clear Environmental Consulting Description: Rag n Bone B.I 1280 Buffalo Grass Place Date Received: 08/15/2024 Elizabeth, CO Date Analyzed: 08/16/2024 Date Reported: 08/16/2024 Collected: 08/15/2024 Comments: Collected By: Josh Berard Collection Address: 433 Hyman Ave Asbestos Non-Asbestos Lab ID Sample Location/ Constituents Constituents Sample# Sample Description (%) (%) 0042613-006 None Detected Cellulose Fiber(Incom) 3% Fibrous Glass(ISO) <1% H-2-01 LAYER 1 Carbonates 65% Paint/Joint Compound,White/White,24°C Aggregate 12% Perlite 10% Binder/Filler 10% None Detected Cellulose Fiber(Incom) 90% LAYER 2 Organic Matrix 10% Drywall Tape,Off White,24°C None Detected Cellulose Fiber(Incom) 5% LAYER 3 Carbonates 65% Joint Compound,White,24°C Aggregate 15% Perlite 5% Binder/Filler 10% None Detected Cellulose Fiber(Incom) 40% Fibrous Glass(ISO) <1% LAYER 4 Gypsum 60% Drywall,Brown/Grey,24°C 0042613-007 None Detected Cellulose Fiber(Incom) 3% Fibrous Glass(ISO) <1 H-2-02 LAYER 1 Carbonates 65% Paint/Joint Compound,White/White,24°C Aggregate 12% Perlite 10% Binder/Filler 10% None Detected Cellulose Fiber(Incom) 90% LAYER 2 Organic Matrix 10% Drywall Tape,Off White,24°C None Detected Cellulose Fiber(Incom) 5% LAYER 3 Carbonates 65% Joint Compound,White,24°C Aggregate 15% Perlite 5% Binder/Filler 10% None Detected Cellulose Fiber(Incom) 40% Fibrous Glass(ISO) <1% LAYER 4 Gypsum 60% Drywall,Brown/Grey,24°C Atlas COPhone Consultants LLC Pe1i�R J' ��� 14 Inverness Drive East,Building B Suite132,Englewood,C 80112 Phone 1-303-799-6100 Fax 1-303-799-3441 www.onea 16 10/10/2024 ASPEN BUILDING DEPARTMENT T ■ A C► BATCH NO. 0042613 PLM REPORT RESULTS NVLAP Lab Code 102031-0 Customer: Josh Berard Customer Project No.: 1561 All Clear Environmental Consulting Description: Rag n Bone B.I 1280 Buffalo Grass Place Date Received: 08/15/2024 Elizabeth, CO Date Analyzed: 08/16/2024 Date Reported: 08/16/2024 Collected: 08/15/2024 Comments: Collected By: Josh Berard Collection Address: 433 Hyman Ave Asbestos Non-Asbestos Lab ID Sample Location/ Constituents Constituents Sample# Sample Description (%) (%) 0042613-008 None Detected Cellulose Fiber(Incom) <1% H-3-01 Mortar,Dk.Grey,24°C Carbonates 25% Aggregate 40% Quartz 10% Perlite 10% Binder/Filler 15% 0042613-009 None Detected Cellulose Fiber(Incom) <1% H-3-02 Mortar,Grey,24°C Carbonates 15% Aggregate 35% Quartz 25% Binder/Filler 25% Analyzed by: `" r' Reviewed by: Atlas COechnical Consultants LLC EIVED 14 Inverness Drive East,Building B Suite132,Englewood,C 80112 Phone 1-303-799-6100 Fax 1-303-799-3441 www.onea 17 10/10/2024 ASPEN BUILDING DEPARTMENT X. CONCLUSION&RECOMMENDATIONS Asbestos was NOT identified within the materials inside the building that were within the scope of the asbestos inspection and bulk-sampling performed on August 14th, 2024; therefore, professional abatement activities are NOT required to remove or disturb the above-sampled building materials. All Clear Environmental (ACE) recommends that when ACM is removed/abated,that only a licensed asbestos abatement contractor using personnel trained in the handling of ACM be allowed to conduct such activities using appropriate methods (HEPA-filtered vacuuming, wet cleaning methods, respiratory protection, protective clothing, personnel decontamination, negative-air enclosures, air monitoring, etc.) XI. LIMITATIONS All reports and recommendations are based on conditions, practices observed and information made available to All Clear Environmental (ACE)by the client and the designated site on the days sampling was conducted. All activities were performed in accordance with all applicable federal, state, and local regulations as well as generally accepted standards and professional practice. No responsibility is assumed by All Clear Environmental for the control or correction of conditions or practices existing at the facility/residence, for and on behalf of the client. Any materials encountered during demolition that were sampled during this inspection should be assumed positive until confirmed otherwise by a Certified Asbestos Building Inspector.Any ACM that will be disturbed should be handled according to CDPHE, EPA(Environmental Protection Agency) and OSHA protocol. All Clear Environmental greatly appreciates the opportunity in providing our services to you. Feel free to call us at any moment if you have any further questions! Kindest Regards, Josh Berard — President All Clear Environmental Consulting 720.982.1513 Josh@AllClearEC.com RECEIVED 18 10/10/2024 ASPEN BUILDING DEPARTMENT — CERTIFICATIONS — •. , ,, . . , , „ • . s - ir 's '.-. \,, , ., ' _ • '".. "I .,4k.4. ; ',,, , SI ....\,/,:,.,„.,...,„,92,,. ti,....-•• 4_4.... ...... - - :•.:-.fi..---._ • 1 * 460:1r ,..,:i. - . . . „ k:. .._ -.:. .ei- • •,, - i ". .. . - r--: Colorado Department . - ,+ of Public limbltit .._ -. anti Lnt,ironment . .. • .. : .. -.: - ASBESTOS .t.,, CERTIFICATION* This oat]tic.that , ..-_, _:-- . _ . .7-••• ., -' .--- E Josh Berard ---- , s, ,,..!- C ertifiestion No.: 23915 - I — $ ... has met the requitrincnits of 2$-1-937,C R.S awl Air Quality Control ,.. ,. CONIIIIina8041 Regulation No_ S.Pan B.and is barb) certified by the 1 -Ilt°''' -..:". :'•::::.-.1 ,. ..-• state oforain the Coldo following discipline: ‘..., ..\,... .. i. :-.• ...:. ,a• :3 - 9• Building Inspector* -4 .-- • ---:•‘ ..-., .. ;.:2• ? r• ., ;..c., '.."-:1.. ' • . .4' •.-.: -;'-',T S hAtartl. tk•ceneber 01. 2023 ---_ . - • ._. ;,', 1%Ores; December 0111. 2024 .-- • „ 1-11F • -. - .. ,..-- __iii . $t•- -1 _. •MA coeloire I.••161 AN*4411b At poservisi.•4• 110 1_ . . r•. novas 06'.410•0-erprword 19.11•1111 norm 41,11V11414.1 •fti. . al 1 ' - 0• iv the Ilasniesse sport*/dam* iimhonnet AV earnmeristaxm '.. ii'- -- • ,_ ,.31 f. 1 . - _ . ,4,. A , IV ,41 I' ..le W •_ .41 . 'OP. I*4-, -4S1, , • 1 -- '. -, •.'1. ."...t• . •'.1-. •••.;?.• ..1•.: i.,.;?.,• k.11`;.: ...y. . .v.,,,,,i,:, .,:.4502,t,',. .-_-_,t,. ,6.0f; .,..:f..!;,;:-..c. :Nr-- Vii, .t.,:c7,-.V-• .--ti',W =!..1;get 4.... ,ww.r.0, 9F4*. 4.--?&A., -4% .4.• 4. "60....P• . 44\ • 10, • ''' RECEIVED 19 10/10/2024 ASPEN BUILDING DEPARTMENT ^I. CHC Training Missouri State Approval MO-136 CI— Environmental Compliance Certification Experts fr www.chctraining.com 1775 W.55th Avenue T RA I NI Nd 303.412.6360 Denver,Colorado 80221 855.60.CERTIFY United States of America CERTIFICATE OF ACHIEVEMENT This certificate is awarded to: jOSHUA BERARD In recognition of satisfactory completion of the EPA-approved annual asbestos refresher training in accordance with the Model Accreditation Plan (MAP) (40 CFR Part 763,Subpart E,Appendix C),AHERA of the Toxic Substances Control Act(TSCA) entitled: BUILDING INSPECTOR COURSE COMPLETION: NOVEMBER 17, 2023 EXAMINATION DATE: NOVEMBER 17, 2023 EXPIRATION DATE: NOVEMBER 17, 2024 COURSE HOURS: 4.0 CHC •o 0.'•..— c/z, 7• . (RAIN!N .yea/fl,PiaNe ��` CEO&Training Program Manager T'OED1SInstructor � 1`,-4 CREDITED . '' CI " •- Credential License ID: ALUMNI „,' CHC Training Certificate No.: Elie. I Verify this Certificate 87279987 R231671-AI-MO Renew this Certificate RECEIVED 20 10/10/2024 ASPEN BUILDING DEPARTMENT T a It i . O• a. 0 t2it • i Ai I 4. IMO J t1 .1 • Mt = a ; �.n V 8 d - 1 r Z E. Li p Q 3 a 4 _ — '9 Y c ii.11 mar gr.IV i Q 10 • I i �, a ci) ' iI ` x I rikr; • J e `- .- id • • t L . c :. J V L " a. r+ .. i ;mill > 4 m = O N • AM P v g Ft t i ,1 ?". i 4 . .. r . r .ir . .A. . v . z . _ 10/10/2024 ASPEN BUILDING DEPARTMENT