Loading...
HomeMy WebLinkAboutFile Documents.1315 Sage Ct.0082-2021-BRES (24) HealthSafe e I NSPECTIO NS HealthSafe Inspections Inc 390 Apple Drive Basalt CO 81621 970-920-2100 Jim Baker CDPHE Asbestos Building Inspector#13437 Ben Baker CDPHE Asbestos Building Inspector#25863 ASBESTOS REPORT DATE 04/11/2021 CLIENT Matt Johnson PROPERTY ADDRESS of INSPECTION 1315 Sage Court,Aspen, Colorado 81611 • t RECEIVED 1 06/04/2021 ASPEN BUILDING DEPARTMENT fr a ' -k �' I 4 C fir . , , j3 ass 2i' "- e-rI ' l'el''-?"idt. `,*, , '-' --' ...,___„' 4 I ry,1 it i 1 ) IP'r _._.. -may. - _ - i" Y?rx`. CLIENT BACKGROUND & PLANS The Client, Matt Johnson, is planning an interior renovation-remodel of the above referenced house and a full demolition of the detached garage/ADUs,which will have impacts of disturbance, detachment, deconstruction, demolition and disposal (5D) of drywall and roofing building materials, of which some are suspect asbestos containing materials (ACM) or suspect asbestos containing building materials (ACBM). Prior to 5D, Matt is required to have an asbestos inspection by a State of Colorado CDPHE certified asbestos inspector who will collect bulk samples of the suspect ACM/ACBM and have those samples analyzed at a certified laboratory for asbestos content. Iglehart Construction Company hired HealthSafe Inspections, Inc. (hereinafter, HealthSafe)to perform a limited asbestos inspection for the house interior and an unlimited asbestos inspection for the detached garage/ADUs. For the purpose of this inspection report, the detached garage is oriented with the overhead doors west and man doors north. VISUAL INSPECTION & LABORATORY FINDINGS An inspection was conducted by Ben Baker of HealthSafe on Thursday,April 01, 2021 with the house vacant during the initial survey, inspection and sample collecting.All suspect ACM/ACBM were identified by homogenous materials and sampled randomly respective to the scope of those materials slated for 5D.The suspect ACM/ACBM collected and analyzed by EPA 600 Method PLM analysis are the following: 1. Garage Orange Peel Surfacing Texture, a homogeneous spray-applied surfacing material/texture [samples 1-5: G-OP-1,2,3,4,5], collected randomly from the garage east wall south corner corner, ceiling next to the overhead door motor, west wall north of the overhead door below the cover plate, second-floor ADU south wall below the west window and north pony wall between the baseboard heaters, respectively, using the AHERA random sampling grid# 15. This surfacing material/texture is on the ceilings and walls of the garage and second-floor ADU. The estimated impact area of 5D is more than 1,000 sf, but less than 5,000 sf(+3,800 sf), requiring a minimum of at least three surfacing/texture material samples. The PLM analytical estimated results: NONE DETECTED. RECEIVED 2 06/04/2021 ASPEN BUILDING DEPARTMENT 2. Drywall System Joint Compound: a homogeneous miscellaneous seam taping compound requiring at least two samples [samples 6-7: G-JC-1,2], collected from the garage north closet SW corner and the second-floor ADU NW closet SW corner, respectively. This material is applied to the garage and second-floor ADU drywall system. The PLM analytical estimated results: NONE DETECTED. 3. Drywall System, a homogeneous taped and joint compounded drywall system (classified as a miscellaneous material as a complete integral system) [samples 8- 9: G-J-1,2], collected from the garage north closet SW corner and the second- floor ADU NW closet SW corner, respectively. These composite layered taped and joint compounded drywall materials are on the ceilings and walls of the garage and second-floor ADU with an orange peel applied surfacing material/texture. The estimated impact area of 5D is more than 1,000 sf, but less than 5,000 sf(±3,800 sf), requiring a minimum of at least two composite core samples of all layers. The PLM analytical estimated results: NONE DETECTED. 4. Garage East ADU Fine Orange Peel Surfacing Texture, a homogeneous spray- applied surfacing material/texture [samples 10-12: ADU-FOP-1,2,3], collected randomly from the garage east ADU bathroom under the base behind the toilet, west wall north of the south electrical receptacle and north wall west of the man door, respectively,using the AHERA random sampling grid# 15. This surfacing material/texture is on the ceilings and walls of the garage east ADU. The estimated impact area of SD is more than 10 sf,but less than 1,000 sf(±920 sf), requiring a minimum of at least three surfacing/texture material samples. The PLM analytical estimated results: NONE DETECTED. 5. Garage East ADU Drywall System Joint Compound: a homogeneous miscellaneous seam taping compound requiring at least two samples [samples 13- 14:ADU-JC-1,2], collected from the garage east ADU bathroom closet SE corner and living space NE corner, respectively. This material is applied to the garage east ADU drywall system. The PLM analytical estimated results: NONE DETECTED. 6. Garage East ADU Drywall System, a homogeneous taped and joint compounded drywall system (classified as a miscellaneous material as a complete integral system) [samples 15-16:ADU-J-1,2], collected from the garage east ADU bathroom closet SE corner and living space NE corner, respectively. These composite layered taped and joint compounded drywall materials are on the ceilings and walls of the garage east ADU with a fine orange peel applied surfacing material/texture. The estimated impact area of 5D is more than 10 sf, but less than 1,000 sf(±920 sf), requiring a minimum of at least two composite core samples of all layers. The PLM analytical estimated results: NONE DETECTED. 7. House Orange Peel Surfacing Texture, a homogeneous spray-applied surfacing material/texture [samples 17-23: H-OP-1,2,3,4,5,6,7], collected randomly from the kitchen area south wall in the TV nook, living room fireplace wall under the SW side of the hearth, master closet west wall north corner, kitchen area west wall below the south window, second-floor north bathroom next to the ceiling vent fan, second-floor east bedroom closet north wall east of the doors and second-floor stair landing area SE corner, respectively, using the AHERA random samplin gRECEIVED 3 06/04/2021 ASPEN BUILDING DEPARTMENT grid# 15. This surfacing material/texture is on the ceilings and walls of the house interior excluding the entry and area south of the kitchen (office, laundry, mudroom). The estimated impact area of SD is more than 5,000 sf requiring a minimum of at least seven surfacing/texture material samples. The PLM analytical estimated results: NONE DETECTED. 8. House Drywall System Joint Compound: a homogeneous miscellaneous seam taping compound requiring at least two samples [samples 24-25: H-OP-JC-1,2], collected from the second-floor east bedroom closet SW corner and the main-floor mechanical room NE corner, respectively. This material is applied to the house interior drywall system excluding the entry and area south of the kitchen(office, laundry, mudroom). The PLM analytical estimated results: NONE DETECTED. 9. House Drywall System, a homogeneous taped and joint compounded drywall system (classified as a miscellaneous material as a complete integral system) [samples 26-27: H-OP-J-1,2], collected from the second-floor east bedroom closet SW corner and the main-floor mechanical room NE corner, respectively. These composite layered taped and joint compounded drywall materials are on the ceilings and walls of the house interior excluding the entry and area south of the kitchen(office, laundry, mudroom) with an orange peel applied surfacing material/texture. The estimated impact area of 5D is more than 5,000 sf requiring a minimum of at least two composite core samples of all layers. The PLM analytical estimated results: NONE DETECTED. 10. House Flat Finish Surfacing Texture, a homogeneous trowel-applied surfacing material/texture [samples 28-30: H-FF-1,2,3], collected randomly from the office west wall south of the desk, laundry room west wall south of the man door and the entry SE wall in the center, respectively, using the AHERA random sampling grid# 15. This surfacing material/texture is on the ceilings and walls of the entry and area south of the kitchen (office, laundry, mudroom). The estimated impact area of SD is more than 10 sf,but less than 1,000 sf(±850 sf), requiring a minimum of at least three surfacing/texture material samples. The PLM analytical estimated results: NONE DETECTED. 11. House Flat Finish Drywall System, a homogeneous taped and joint compounded drywall system(classified as a miscellaneous material as a complete integral system) [samples 31-32: H-FF-J-1,2], collected from the laundry room NW corner above the cabinets and powder room south corner under the vanity, respectively. These composite layered taped and joint compounded drywall materials are on the ceilings and walls of the entry and area south of the kitchen(office, laundry, mudroom)with a flat finish applied surfacing material/texture. The estimated impact area of 5D is more than 10 sf,but less than 1,000 sf(±850 sf), requiring a minimum of at least two composite core samples of all layers. The PLM analytical estimated results: NONE DETECTED. 12. House Powder Room Wallpaper, a homogeneous miscellaneous material requiring a minimum of at least two samples [samples 33-34: PWD-WP-1,2], collected from the powder room south corner and west corner under the vanity, respectively. The PLM analytical estimated results: NONE DETECTED. 13. Master Bedroom Wallpaper, a homogeneous miscellaneous material requiring a minimum of at least two samples [samples 35-36: MST-WP-1,2], collected from RECEIVED 4 06/04/2021 ASPEN BUILDING DEPARTMENT the south bay window area under the west window and the east window, respectively. The PLM analytical estimated results: NONE DETECTED. 14. Garage Roofing Tar Paper, a homogeneous miscellaneous material requiring a minimum of at least two samples [samples 37-38: RF-TP-1,2], collected from the garage roof NW corner and SW corner, respectively. The PLM analytical estimated results: NONE DETECTED. A total of 38 suspect homogeneous ACM/ACBM bulk samples were collected, and 38 samples were analyzed. The bulk samples were analyzed by EPA 600 PLM analytical methods by a NVLAP accredited laboratory in accordance with Colorado State Regulation 8 for the presence of asbestos mineral fibers. There is NO asbestos in all 38 samples. See supporting Hayes Microbial Consulting, Inc. data report#21011122_1. RECEIVED 5 06/04/2021 ASPEN BUILDING DEPARTMENT •• x / � Q ; 0 a sz j \ Z i , I / l /j i .1� \`J. e / �i:., •b i i 1 �1111 / ISO / — \ i ir `•° I / OF ' w w O / L i Il� /• L r / — .-, \ 0 / L \ iIi i \� 7 ni- .=.. —tura Al \ § i ; s ; I It> g_o i _sue C1:,.i ja RECEIVED 6 06/04/2021 ASPEN BUILDING DEPARTMENT U ! f, m i> Q _ . , t_____,, ‘,. , i., , , ., if a � ' ' II m r �• 11 Tf <'.,, I r- i I ‘',mik\r-7.14$,,, \., .A 0 i to•N‘s‘ .,, 1111 -1) / s,,,,; ..„ .., , ,, ,..,. / i \,,,:,___:,,4 ik, ,,<// \',_ „..._ ff i t. i; Y`C^�,, 4 Ci+ J ti® ik i filili 1 . r� o : 4)-- ,i/ !UPI '44 11110 // ftip I % / ,0 i / 0, \\� %i - \\\ / 0 0 111-L---.--;--I.: , . 11111:111- • 4) II '•� L 4 If , : 1 i9 I ___,, ..-.......N_,, RECEIVED 7 06/04/2021 ASPEN BUILDING DEPARTMENT HEALTHSAFE CONCLUSIONS • There is NO asbestos in any of the suspect building materials slated for 5D in this full garage demolition and house interior remodel project. NO asbestos abatement will be required for any of the building materials.All building waste and debris can be disposed of in any landfill which accepts normal, non-hazardous building waste. Sincerely Submitted, Ben Baker RECEIVED 8 06/04/2021 ASPEN BUILDING DEPARTMENT COLORADO & FEDERAL ASBESTOS REGULATIONS SUMMARY Regulation No. 8 Part B—Asbestos of the Colorado Department of Public Health and Environment(CDPHE),Air Quality Control Commission requires a State-certified Asbestos Building Inspector to inspect and collect bulk samples of all suspect asbestos containing materials (ACM) or suspect asbestos containing building materials (ACBM) prior to their disturbance, removal or demolition and disposal. The suspect materials shall be analyzed by a NVLAP accredited laboratory by polarized light microscopy(PLM) using EPA 600 analytical method.A material which is estimated to contain more than 1% asbestos is classified as ACM/ACBM and regulated by the State and Federal governments.Any friable (able to crush or reduce to powder by finger pressure) asbestos with trace amounts of asbestos fibers or less than 1%must be point-counted using EPA 400 analytical method to prove that it is indeed less than 1%; if not, it must be classified as ACM/ACBM and shall be treated as a State and Federal regulated material.Any friable asbestos containing material (greater than 1% asbestos concentration) or ACM/ACBM that could be rendered friable during its removal or demolition and disposal shall require an asbestos abatement by a certified asbestos abatement contractor to remove and dispose of the material(s). A Colorado State (CDPHE) issued asbestos abatement permit is required for the following trigger levels of ACM/ACBM: 1. Residential buildings of four or fewer units--if more than 32 square feet of any surface coverage (e.g., gypsum wallboard or drywall and associated applied surfacing materials/textures, acoustic sprays,joint compounds,plaster, etc.), 50 feet of asbestos covered or asbestos insulated pipe or any material which would fill a 55-gallon drum is going to be disturbed, removed or disposed of, an asbestos abatement permit is required. 2. Residential complexes with more than four residential units, public access areas to a residential building, commercial and retail buildings, public and civic buildings, industrial buildings--if more than 160 square feet of surfacing materials, 260 linear feet or more than 35 cubic feet(NESHAP) or 55-gallon drum(CDPHE) of suspect ACM/ACBM is going to be disturbed, removed or disposed of, an asbestos abatement permit is required under NESHAP and by the CDPHE. See note below on OSHA. The regulations require an absolute minimum of 3 samples (EPA suggests 9)per homogenous suspect surfacing and TSI materials and an absolute minimum of 2 samples of homogenous miscellaneous materials or any number of"samples sufficient to determine whether a material is ACM" (Reg8.IV.D.3). More samples are required based on surface area or volume. These are minimums; the asbestos building inspector has the field responsibility to determine homogenous materials and the number of samples to collect per material; more than the minimum number of samples may be necessary at the discretion of the inspector.An assessment of friability and functional space conditions of the materials are also the inspector's field responsibilities. RECEIVED 9 06/04/2021 ASPEN BUILDING DEPARTMENT OSHA compliance is required for all employers and employees no matter the quantity of asbestos present with strict regulations regarding 10 sf or more of TSI or friable surfacing materials, and therefore it does not matter what the quantity or State trigger levels are: all suspect ACM/ACBM shall be inspected and tested for asbestos prior to their disturbance, removal and disposal for worker protection and safety. See EPA 40 CFR 763.121 Worker Protection Rule, OSHA 29 CFR 1910.134 Respirator Protection Standard, OSHA 29 CFR 1910.1001 General Industry Standard and OSHA 29 CFR 1926.1101 Construction Standard regulations when dealing with asbestos hazards. Note: County or City regulations may be more stringent. RECEIVED 1 06/04/2021 ASPEN BUILDING DEPARTMENT 4 AYE S MICROBIAL CONSULTING #21 o1 1 1 22 Analysis Report prepared for We would like to thank you for trusting Hayes Microbial for your analytical needs! We received 38 samples by FedEx in good condition for this project on April 2nd, 2021. HealthSafe The results in this analysis pertain only to this job, collected on the stated date, and should not be used Inspections in the interpretation of any other job. This report may not be duplicated, except in full,without the written consent of Hayes Microbial Consulting, LLC.. 390 Apple Drive This laboratory bears no responsibility for sample collection activities, analytical method limitations,or Basalt, CO 81621 your use of the test results. Interpretation and use of test results are your responsibility. Any reference to Phone: (970) 920-2100 health effects or interpretation of mold levels is strictly the opinion of Hayes Microbial. In no event, shall Hayes Microbial or any of its employees be liable for lost profits or any special, incidental or consequential damages arising out of the use of these test results. Matt Johnson 131 5 Sage Ct Aspen, CO 81611 44( n *A....0 Collected: April 1, 2021 Steve Hayes,BSMT(ASCP) Received: April 2, 2021 Laboratory Director Reported: April 9, 2021 Hayes Microbial Consulting,LLC. �ciED ST,40T7 J s 7----- AL�o,,o \ w 1DPH 1 tia � \+T CnnuDpme 4C pROjE Health Pubhc RECEIVED EPA Laboratory ID: VA01419 Lab ID: #188863 DPH License: #PH-0198 06/04/2021 Hayes Microbial Consulting,LLC. 3005 East Boundary Terrace,Suite F. Midlothian,VA.23112 (804) 562-3435 contact@hayesmicrobial.com Page: 1 of 7 ASPEN BUILDING DEPARTMENT Ben Baker #21011122 HealthSafe Inspections Matt Johnson 390 Apple Drive 1315 Sage Ct Basalt,CO 81621 Aspen,co 81611 Asbestos PLM Bulk (970) 920-2100 EPA 600/R-93,M-4/82-020 # Sample Material Description Non-Asbestos Fibers Asbestos Fibers 1 1 -G-OP-1 Brittle/White None Detected 2 2-G-OP-2 Brittle/White None Detected 3 3-G-OP-3 Brittle/White None Detected 4 4-G-OP-4 Brittle/White None Detected 5 5-G-OP-5 Brittle/White None Detected 6 6-G-JC-1 Joint Compound/White None Detected 7 7-G-JC-2 Joint Compound/White None Detected 8 8-G-J-1 Drywall/White/Brown 5%Cellulose Fibers None Detected Joint Compound/White None Detected Joint Compound/Drywall/White/Brown 5%Cellulose Fibers None Detected Lab Note:Composite of Drywall&Joint Compound. Collected:Apr 1,2021 Received:Apr 2,2021 Reported:Apr 9,2021 RECEIVED H A Y E S0 Project Analyst: Date: Reviewed By: rD�rte/O 4 2 0 2 1 MICROBIAL CONSULTING Darien Williams, j ,� C''C/"" Q'"t 04 09 2021 Renaldo Drakes, `� 04 09 2021 3005 East Boundary Terrace,Suite F. Midlothian,VA.23112 (804)562-3435 contact@ha esmicrobial.com BUILDING DE ASV Ben Baker #21011122 HealthSafe Inspections Matt Johnson 390 Apple Drive 1315 Sage Ct Basalt,CO 81621 Aspen,CO 81611 Asbestos PLM Bulk (970) 920-2100 EPA 600/R-93,M-4/82-020 # Sample Material Description Non-Asbestos Fibers Asbestos Fibers 9 9-G-J-2 Drywall/White/Brown 5%Cellulose Fibers None Detected Joint Compound/White None Detected Joint Compound/Drywall/White/Brown 5%Cellulose Fibers None Detected Lab Note:Composite of Drywall&Joint Compound. 10 10-ADU-FOP-1 Brittle/White None Detected 11 11 -ADU-FOP-2 Brittle/White None Detected 12 12-ADU-FOP-3 Brittle/White None Detected 13 13-ADU-JC-1 Joint Compound/White None Detected 14 14-ADU-JC-2 Joint Compound/White None Detected 15 15-ADU-J-1 Drywall/White/Brown 5%Cellulose Fibers None Detected Joint Compound/White None Detected Joint Compound/Drywall/White/Brown 5%Cellulose Fibers None Detected Lab Note:Composite of Drywall&Joint Compound. Collected:Apr 1,2021 Received:Apr 2,2021 Reported:Apr 9,2021 RECEIVED HA V E S Project Analyst Date: Reviewed By: rD�rte/O 4 2 0 2 1 MICROBIAL CONSULTING Darien Williams, of j ,� C'.(/"" Q'"6 04 09 2021 Renaldo Drakes, `� (/ 04 09 2021 3005 East Boundary Terrace,Suite F. Midlothian,VA.23112 (804)562-3435 contact@haa„esmicrobial.com BUILDING DE ASV Ben Baker #21011122 HealthSafe Inspections Matt Johnson 390 Apple Drive 1315 Sage Ct Basalt,Co 81621 Aspen,co 81611 Asbestos PLM Bulk (970) 920-2100 EPA 600/R-93,M-4/82-020 # Sample Material Description Non-Asbestos Fibers Asbestos Fibers 16 16-ADU-J-2 Drywall/White/Brown 5%Cellulose Fibers None Detected Joint Compound/White None Detected Joint Compound/Drywall/White/Brown 5%Cellulose Fibers None Detected Lab Note:Composite of Drywall&Joint Compound. 17 17-H-OP-1 Brittle/White None Detected 18 18-H-OP-2 Brittle/White None Detected 19 19-H-OP-3 Brittle/White None Detected 20 20-H-OP-4 Brittle/White None Detected 21 21 -H-OP-5 Brittle/White None Detected 22 22-H-OP-6 Brittle/White None Detected 23 23-H-OP-7 Brittle/White None Detected 24 24-H-OP-JC-1 Joint Compound/White None Detected 25 25-H-OP-JC-2 Joint Compound/White None Detected Collected:Apr 1,2021 Received:Apr 2,2021 Reported:Apr 9,2021 RECEIVED H AY E S Project Analyst: Date: Reviewed By: rD�rte/O 4/2 0 2 1 LV V Darien Williams, 0,,,,, 6(...,-6 Q''"� 04- 09 -2021 Renaldo Drakes, P (/ ) 04-09 -2021 MICROBIAL CONSULTING - //" 3005 East Boundary Terrace,Suite F. Midlothian,VA.23112 (804)562-3435 contact@ ah esmicrobial.com BUILDING DE RTMENT Ben Baker #21011122 HealthSafe Inspections Matt Johnson 390 Apple Drive 1315 Sage Ct Basalt,Co 81621 Aspen,Co 81611 Asbestos PLM Bulk (970) 920-2100 EPA 600/R-93,M-4/82-020 # Sample Material Description Non-Asbestos Fibers Asbestos Fibers 26 26-H-OP-J-1 Drywall/White/Brown 5%Cellulose Fibers None Detected Joint Compound/White None Detected Joint Compound/Drywall/White/Brown 5%Cellulose Fibers None Detected Lab Note:Composite of Drywall&Joint Compound. 27 27-H-OP-J-2 Drywall/White/Brown 5%Cellulose Fibers None Detected Joint Compound/White None Detected Joint Compound/Drywall/White/Brown 5%Cellulose Fibers None Detected Lab Note:Composite of Drywall&Joint Compound. 28 28-H-FF-1 Brittle/White None Detected 29 29-H-FF-2 Brittle/White None Detected 30 30-H-FF-3 Brittle/White None Detected Collected:Apr 1,2021 Received:Apr 2,2021 Reported:Apr 9,2021 RECEIVED 0 H AY E S Project Analyst: Date: Reviewed By: n 66/O 4/2 0 2 1 Darien Williams, ��� k ,�U1.,,,,6 04- 09 -2021 Renaldo Drakes, .P (/ L ) V0V4/-09 -2021 MICROBIAL CONSULTING .1- V /// 3005 East Boundary Terrace,Suite F. Midlothian,VA.23112 (804)562-3435 contact@ ah esmicrobial.com BUILDING DER BE RTMENT Ben Baker #21011122 HealthSafe Inspections Matt Johnson 390 Apple Drive 1315 Sage Ct Basalt,Co 81621 Aspen,co 81611 Asbestos PLM Bulk (970) 920-2100 EPA 600/R-93,M-4/82-020 # Sample Material Description Non-Asbestos Fibers Asbestos Fibers 31 31 -H-FF-J-1 Drywall/White None Detected Joint Compound/White None Detected Joint Compound/Drywall/White None Detected Lab Note:Composite of Drywall&Joint Compound. 32 32-H-FF-J-2 Drywall/White None Detected Joint Compound/White None Detected Joint Compound/Drywall/White None Detected Lab Note:Composite of Drywall&Joint Compound. 33 33-PWD-WP-1 Paper/White 70°%o Cellulose Fibers None Detected 34 34-PWD-WP-2 Paper/White 70°%o Cellulose Fibers None Detected 35 35-MST-WP-1 Bulk Material/Tan 80°%o Cellulose Fibers None Detected 36 36-MST-WP-2 Bulk Material/Tan 80°%o Cellulose Fibers None Detected 37 37-RF-TP-1 Tar Paper/Black 30°%o Cellulose Fibers None Detected 38 38-RF-TP-2 Tar Paper/Black 30°%o Cellulose Fibers None Detected Collected:Apr 1,2021 Received:Apr 2,2021 Reported:Apr 9,2021 RECEIVED (110 H A V E S Project Analyst: Date: Reviewed By: n r:6e./0 4/2 0 2 1 Darien Williams, ��� /�j �U1.,,,,6 04- 09 -2021 Renaldo Drakes, .P (/ ) V0V4/-09 -2021 MICROBIAL CONSULTING .1- V /// 3005 East Boundary Terrace,Suite F. Midlothian,VA.23112 (804)562-3435 contact@ ah esmicrobial.com BUILDING DBE RTMENT Ben Baker #21011122 HealthSafe Inspections Matt Johnson 390 Apple Drive 1315 Sage Ct Basalt,CO 81621 Aspen,CO 81611 Asbestos Analysis Information (970) 920-2100 Analysis Details All samples were received in acceptable condition unless otherwise noted on the report.This report must not be used by the client to claim product certification, approval,or endorsement by AIHA,NIST,NVLAP,NY ELAP,or any agency.The results relate only to the items tested. Hayes Microbial Consulting reserves the right to dispose of all samples after a period of 60 days in compliance with state and federal guidelines. PLM Analysis All Polarized Light Microscopy(PLM) results include an inherent uncertainty of measurement associated with estimating percentages by PLM. Materials with interfering matrix,low asbestos content,or small fiber size may require additional analysis via TEM Analysis. TEM Analysis Analysis by TEM is capable of providing positive identification of asbestos type(s) and semi-quantitation of asbestos content. Definitions 'None Detected'-Below the detected reporting limit of 1%unless point counting is performed,then the detected reporting limit is .25%. New York ELAP Per NY ELAP198.6(NOB),TEM is the only reliable method to declare an NOB material as Non-Asbestos Containing. Any NY ELAP samples that are subcontracted to another laboratory will display the name and ELAP Lab Identification number in the report page heading of those samples.The original report provided to Hayes Microbial Consulting is available upon request. RECEIVEI H AY E SQ 06/04/2021 MICROBIAL CONSULTING 3005 East Boundary Terrace,Suite F. Midlothian,VA.231 12 (804) 562 3435 contact�a hayesmicrobial.com ASPS 7 of 7 BUILDING DEPARTMENT 1--0e'BlthSafe Inspection's SHIP: FEDEX ENV 50 ASBESTOS • i .! l L _t f DATE: 04 22 2021 390 Apple Drive ._ , MICROBIAL CONSULTING Basalt, CO 81621 e159 8641 7262 Job Number: II��illNIIIIIII11111111111111111111111 21011122 Job Name: /v1 A f r Jct,,,sate, Collector y4fa..g l ef 3 i 5 j��y e Cfi 3 n / c,/Ser Mobile: 970-920-2100 Email: Date Collected: U y U Mobile: l U N.ii healthsafeinspections@gmail -_j--�-�, - II Note: ,6 Analysis Type i 1 es7 � � e/� r330 5va,c„ /. e r7;�, - _s Analysis Methods PLM Bulk EPA 600 I� • Turnaround Times _ 3 Hour Same Day 1 Day I 2 Day 3 Day ' 5 Day Point Count 400 Point,1 000 Point 3 Hour Same Day 1 Day 2 Day 3 Day 5 Day Vermiculite CARE 435 TEM Air 3 Hour Same Day 1 Day 2 Day 3 Day 5 Day EPA AHERA,NIOSH 7402 Bulk Chatfield - Same Day 1 Day 2 Day 3 Day 5 Day - Same Day 1 Day 2 Day 3 Day 5 Day Wipe ASTM D6480-05 • Microvac ASTM D575 - - Same Day 1 Day 2 Day 3-Day 5 Day 5-09 _ _ PCM Air NIOSH 7400 - Same Day 1 Day 2 Day 3 Day 5 Day -- :�,-- - -�a Same Day 1 Day 2 Day 3 Day # Group Number -. .. -- --_ -_ ---- ., TN--m7—a,-�.r —_._�_�-- —A____ _ _ _ 5 Day Sample Name Analysis Type+vti VTumaround Volume/Area 1 Stop (+)� 1 G vh I _ 2 _ C.; 0;) )_ l�L Ai 5 �);r 3 3 -I rj v,) 4 vi G-u c (; v?� y 6 G•-3c- 1 7 G -j c- 8I 9 G -7-I 10 Ci -7-3- ADv - Foie -I III 4 0 v -1L)i) )- 13 410u -rvi' 3 1111 14 1Dz-, - Tc- I 15 A1) - •T( -)- - I 16 4(.) ,3 17 /) I)li - J--)- Released by: � (74rED Date: 0 cl/a.' Received By: z .,� � I Hayes Microbial Consulting,LLC. Date: 3005 East Boundary Terrace,Suite F. Midlothian,VA. 23112 (804)562-3435 contact Nhayesmicrobial.com / 21 Form T 2 .Rev.3, I C71. chain of Custody ASPEN BUILDING DEPARTMENT t '..". ' '' ''' • ______......mommommEMIIMMENIMMI. 11.11111011.111111111.11M1 2-2- i;ii°9"lilIllIIl.l*ll. IMI.IillI.II.11li . H - OP • 7 2. , 13T'-1 2_.5- liganill.111.1111111111.11.11111111111111111.111.11111111111.11.1111M M11.1.1....remm..1111111 .111.111111111111111111.1 z 377� iiiiiiiiii.1.111111.111.11.1111.1M111 11111111.1. 11.11111111111111111111111011111111111.1 7-: ass ��r� 11111.111.11110 .3� 3o t fiF--F Y'- � - 32 . mii.....11.1Mr111.. 1.111111111111 �- 33 riiiiiii1iErrlrl C111.11111.111.11.1 351 f4 i- iii k/ +' 111.1111=1.11 35 T- wr'-1 - :1111111111 — 319 M5 - w? -)- 3 7 RP- P- I 3 ` � - 1 p o I SHIP: FEDEX - ENV SO ASBESTOS 1 I\I DATE: 04-02-2021 Lil 8159 8641 7262 ������ 81591 641 7261111110 21011122 1- 9 7 . . 4 1 . Lig K/ _ Li _____ _ INIE .:,) . . 50 1 ____. , • 06/04/2021 -- 1 1 BUIL(. ;DEPARTMENT +yv ' .4. !^' ;'•f1.:.♦ , ffi, �1�IffI•• ,1i.�.-fl.,, .. !frP'' •,ii ..r-►1" •••ti iWa: . - ^� �1P 1�►Y1'••.. l--. � 'ii. .;.^ ��l %�/.,•x t. \�,�-- � �i1 '�����—%•�i/.,•�;:..::\� /��/ ,,y� -. ---•�.�i%' 7�?'.V~�i1'�"J ' t d 7//0 .-.\t.,*tok\.•/ '"X.l.%4%:i Z.\,N 0• 040. ,1 f/, .�p . 41f4�N,r ,r• ,/./6.r. 1�.. \ 1 . A - h . a r b . 1.1 r•/,%'b i. �• f % .%' ,b M a I''_ \ .►t` •• �� '► . r % •I b �C\.. ./.f .%% A...„'b \►'�\, .••/ .I,1./\li%' � 'b.\�1. •/.r I,/ :v 1 1. r IL Jr. /11 1. . i IId,11 • v1. f♦. yr,''/i/i./• •H.. e..\ :: ,;,111;,'/:.40..•. ..per,..' ,, j1/,1.1p t 147 , i A y ..1 - : • 1� � A � • 1�J.m ' •� y ' q, i 1 x • i . I�. ti _▪ - ?. t .4 l :1 ._r•-..L '1 • -.: •' ..: 1 .n.1., 1. .1,1,.*i'*, .J.ri,lri'to, 1.1 1i �r , . . . • • ', . r S .�+,1 ,1 .lt.tJ,tl. it"i.,.rV. il. rJ� .tJ. .�1.�.tty1't,,S,$.�i�dJ.H��1.V,J.V,IY.n,1 .lt U..1t f},tr rrt- . ...!..,...A..,..uire, -.-- cr, •• .,:.:*.A.: .' .. . ....„....... � = r� •...: - C:' ..;•..:1 ,..- CM- t teN .. ,A ram^ COD w Milt p ��. O . ,• r - 0 � _ .•� - 4444., ^ jfl \ \\ r 0--.:4„—., .,_ t„ s, : , � . . .,....,:a. 4,.... �� � t r* N... ._: . N ( y. p Its •.. IMMI O = = ^ 3 F - ' ;AI'''. 4.C51:10. ( =..- —-----: - f:c. izo 'D /� ' S _ R . hI Fi(ifi,:ita tp, 1 f:;., „,,,, 4 .,: ....::...:. 1,-, )714.,....t;„....7:10-1-:.......1*. ..'" .•:.”4-.•"-i•:-.+0, o a• = , "• tv ▪ ,egi..,„; 73 -, - '% ; t t 'Le 41 fa 4 1 1 11 1 1 'V l ? 'it! A ,. l4l x1 +ia atoitxlt.(Frlia,+.cax? u > > . fe SS oi( ) A#� �� t, T T qi- T , T �T !... '.11.CS:1-Ii.t:tikl2NtOrkflY1W4:5•ZIN *I) Fie, .s*:. /(4,..„!,,i :� N?i .Oii,.'tyii r:r::�:4• t l ...'illiiiii....':i•. :I..i.:..I..iJin :':e,,, .••►. ...i„.,„q ... R :g ' ii.4 •.1,-,:,....!•• 1 .\.`iN �'14•.., ,a.-,-A ..I .51..riii ,, \.-. 1.; 0•0 11j,;" . a ..• ; ;' u . �Y . :. fC:{1.0..1 .62-I6 �' 1t1•Iflf,' 4.t:1 '::•J..4e..iii"•r/".10;' \7 :' i Iy. , t P.� ' 4 0 . t,. dl /% V . :•I• %• \rZ aI �i ! ' E „ / - .., - j t/ p, 13 J , ►11im,0 . 1 l om., tayoZIpOssQ0 //tI•..,...00 _-H4&.: 4 �1i ��00 .-'4E! //4L•i1�.,-;1•\1, ' .;' ..^j :•71`.,--:.4 BUILDING DEPARTMENT /::J�♦•�.•,�,, / i'1‘+��.�•�.1,r�, i+1��1�t�t�•• \ti .•t�t��;t/•*•• a i t t�+.�t`t�•• �tf. •tttl tit t•.a \ ••+p+��1;t�t••• s� 1't i•• \Ti .+11't4•• \, .V t�'• �•�.J�111 jl%°i• q 4►440,•�•/•la :�►1Y1.•�.4,;,I. :;:tai•►�I�,too . ,.i��.i�f1+1�ieei., .;.:::44.40•vq„ 4 g4��0,.,� 001:�, v.11,�►��j��40,,,,, .i; it�►►•�1�1,,,/�i•, .i,,N.,4,mi.t: +t.: ►1%11$/ ,%. „��1�1��..0,0,•$1,1).,v1,1:0►40,140., 410.44. /j�f0p,„\{1140.4,0,14,,,n ,va,',11� 4.4.0,001/f/7;.s�yl,:to.-,I/./,/f//v,.i,,;,;• t,1./ /j/ff/i.•:y1;'1►1►1►�I0,1,,#/....�yAlik itz::::0 O•�tp,,,/IA,\\'�Zi;111iiN,41,,, �h\..�r4►:lH1j0,l,,/j�fir,\.\1,,,w,.,111p11,/,,,-4,, r!,,§N..1.11/1//i;�:,,,\,11:,,,Hski,/i�r;i,',4;,,,..►,',/,;,;r:4��;I:iN��•.44,"%if41 1.',*1.►1i:1111/irs'1 y.l,�;�-'-, ..�'t• '. f//nia\'!�ir;iiti�' ///�\a�"!��r':,:i(' /1/� ti •(i.i,�4../// a�a'�4�i•�•i�r;�4� !J/n\�a..��•li.i�r<<�-•%f/^a� �'!��'�il" ///�a`a`,!;i•,iiS yG ///^\,a.. �rr,•,1. 4i J//^a\ail��.:�.•' ..�,,. -1,14011%V' r. 44/1�yity!''''� ` iltg tt'o.:1t:1:::"' /4SAIa��',ta; r//j0h\ya�y.,yi0,,,; jff�/,4%:,, ;,;.,,._f/fp...\%,,,'f';t. /sse,1,1k ` %/lts�\ya;r�"�. �',a �yaN\ !//i ,yN\ / Ott\a\ /yi: �y�\y\ /0/ ��\\N\s f/f, ��y> f//i �yy\y\ f/ f a / ,•v ����t ' •ii��C-...� aY •Y �Y V 4 Y �Y�'iY V Y� Y Y Y Y YLea Y W i i� f E:i r ,r�r /ice, �. -SJI,, ......„,,JICI, IUI•.....UIIUIJt,,,,JUiIUI,IL,�L, ,. l.e,„ . .$'�J.J,JU I�j J,IUI,II��U�,,....„1,IU,.....UI,,UI(lJ1,iL;lJ,;Ul, liul,JUI,iUJ,J AIL �� _? 4.�j►...."- a.ivvvv'�'i�'vvvvvv C!►`v° +L•1� v v avvv`v '•, • .•. :- _ �.. \* :s , * (fig �••.. .....-sue v \ ,J zz :• ^: ii/� '—'� is Colorado Department •....t ay of Public Health (Cc ' �� and Environment )) ` ;.:_ =_ �) ASBESTOS (« - -.: f� CERTIFICATION* � '= r`tlp ����\�` 1. C�":�:'/,irii aria '�) This certifies that c, _-__` +(/// ) ») Benjamin L Baker « o,"-",r_: `., (Cc _ . P_= =, ' _ ='-� Certification No.. 25863 ac .,440''., )) has met the requirements of 25-7-507, C.R.S. and Air Quality Control iC:':::;;)»lY;. 4 ,o: 3) Commission Regulation No. 8, Part B, and is hereby certified by the  =` : : �' � state of Colorado in the following discipline: Kc = _ =~ � -4a)) i&.---ii_.;"---,-;:,:f.-1.e.t:. . t ' �) Building Inspector* Ic >�»>;. ��_:::.;��) Issued: September 08, 2020 {ic; :;,,.�;:,•C •: _ )) (cC `22 ?)) Expires: September 25, 2021 OK = =�:•% s ue s/ ) CC'; .. .r. ;•�%;=%= ) .This certificate is valid only with the possession of a (lC7. = Z�: `��• ,) current Division-approved training course certification (tom-•law. _ :,• •,5,- .J. , in the discipline specified above. -,IAr//' . .�) Authorized` CD Representative ((C �`si�*��=~• 53 SEAL « 1 iii%%:. :1.1 iFF:tft-:;-:1.',7*i..!--V, .� -'� �•• rla,• PN9'a'• •Ia•M"4 Pa./\..a,/44./'a.I'a•ON 4."IS•Ia./'a.••4^4 Pa• ./'a.Ia •I'\•n./�.n,•/t i I'a.Ia•n4 n.Ia1• A/ .I'ar �- ..� tL.�Urt Ital II'la I� ;�etriti nle, IMIntaltRIr�l„ 1;nM121I l terill:trInt tatta�,.1Jn�Jrl J 'IvAT �.I t'll tln�J .� un im14,r ..,,sit;, D *:. , ,. % 1' ,CAI ,;>•lA ,% 4 ; ; �,.,, •��%�\\` /°I%1,,77i.' \ Y,41%;,.Jli \`I/°°I° '.ii:,..\�\\v1:1°L:'P�; �\014:7'.'ii \i, k/°/ .�4,' tt4.4'/°II°I. •Y \ %°/°%;'• ;h;„ya 1\•'Y%`f�i i+• ===.�►\\\//i ,ri,•,�;, \,Nv/ir!;r;••,,.;,.,\Z�\v/�°'�''�0�%� :���,�/° '',�;�';��� \i�yv/ /'�;�';,. \�N\/1�//�9 `r5�r,>\�\\V1�11,�,',w�•�e•. Ii°i!',;•'•'.,�r: i\\\\//�Ir-�.�Z�++ ,•« ;;--7`1\;41/,,,,*:4'.l.,tl, Azi,4 N,d/�•,ff1r,,0,,\1V///,ir,1'„�,•,,,,,.\�r/,,,r{F•P!•;,,,„,\1\y/I•�r,i1;Iee ,l•` \y\�I/{'I.1 •t•'1 .�\,It ei," Nei �//I of�....,,�,t,-$\�//;;;g�� �, '••.�•'1�tt\ ����lii/IPI•��+1�tltl��:y�i/lllllisl•1.,�\tl\��rli%11P1•il•1ll�tt\i��r�i11jP1Pi0f11�1t\y``\r��i%'P�flil`1��1y�\Zr//. 1/11i �yFl�t\\�Yf� ,1��/1°�p/ie.N!da\��v/��di%i, :ie 't%•t 1►I�j,-1,�0R/i1/1/1111�1;10,,�`!�t/i0,..,.1:$�4,!\,i i j/il/114►•�++1`A4,:4,°t/1/I►1►1���►e.,, flotIj►m►+f1�\�\i'`,14.,00.,{tt�li'% jl..f 14 ►,�tlS`4,v.1j104,440f► 0t. .; '.V11f10,i'o►' I ♦. • 4 r. 4-........, 4 r. trii+�. �i,� t.••t�.. /^ a�+�.�. /,`• ......... AS'E BUILDING DEPARTMENT