Loading...
HomeMy WebLinkAboutFile Documents.688 Spruce St.0119-2020-BRES (18) THE CITY OF ASPEN 74-jk City of Aspen and Pitkin County 14- FIREPLACE & WOODSTOVE REGISTRATION *Parcel Id number: 273707400009 -- -- -- Street Address: 688 Spruce St Owners Name: MNKN, LLC *Required—Contact Assessors offices at 920-5160 Registration will not be accepted without a Parcel Id number List all devices in your home (2 are allowed per building, except for gas appliances) Note:If the number, type and location on this registration form do not match what is show on your plans or what is actually installed,your permit or Certificate of Occupancy will be denied. Type of Building(circle one): CReside ntiaa Other Type of device Room Existing New Make & Model Wood burning fireplace (select one) ?Site-built masonry ?Factory built insert: model number: • Gas log fireplace (select one) 1. Living Room X ?Site-built masonry ?Factory built insert: model 2. Outdoor Room X number: Isokern BV-46 _ Certified IN • Gas fireplace appliance (attach spec sheet) If any devices are being removed, please describe here, i.e. "old woodstove removed from living room" existing house to be demolished, scrape and replace Dgkally signed by Mike Chmura Mike Chmura DN cr Mike Chmura,qou D,t:l-miYe0.15I6 4:1406' 10/15/2020 Date:2020.10.151634:14-06'00" Signature of applicant Date RECEIVED G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc over 10/29/2020 ASPEN BUILDING DEPARTMENT ASPEN/PITKIN COUNTY FIREPLACE AND WOODSTOVE REGULATIONS In order to keep our air as clean as possible,the elected officials of Aspen and Pitkin County have passed ordinances to regulate the number of fireplaces and woodstoves that can be installed in any building. Building permit applicants must file a fireplace/woodstove registration with the City of Aspen Building Department or the Pitkin County Building Department before the building permit is issued. Pitkin County is separated into 2 areas. One is the non attainment area,which includes the City of Aspen and the Metropolitan areas of the county,i.e. Mountain Valley,Red Mountain,Difficult Campground,T Lazy 7 Ranch,and part of Starwood. The other is the attainment area which includes the less densely populated parts of the county,i.e.Brush Creek Village,Holland Hills and Old Snowmass. Decorative gas appliance:A device utilizing natural gas as a fuel gas designed to appear as a real fireplace with a 4 to 5 inch Class B vent or direct vent,fixed glass door and a firebox no deeper than 24 inches. Certified Woodstove:Colorado Phase III certified woodstove or a Phase II EPA certified woodstove. Gas log fireplace:Meet all codes for burning wood but are used with gas logs. They are not allowed in bedrooms. Aspen and Metropolitan Areas of Pitkin County in the non attainment area New buildings in the non attainment area may have either 2 gas log fireplace or 2 certified woodstoves or 1 each. They may also have an unlimited number of decorative gas appliances. Wood burning fireplaces cannot be installed,nor may coal be used as fuel. Remodeling or an addition to an existing home in the non attainment area • If the building has 2 or more fireplaces, gas log fireplaces or woodstoves,they only devices you can add are decorative gas appliances. • If the building has 1 fireplace,gas log fireplace or woodstove,you may add 1 gas log fireplace and an unlimited number of decorative gas appliances. • If a building has more than 2 fireplaces, gas log fireplaces; if one is affected by the remodel it must be removed. • If a building has only 1 or 2 fireplaces,woodstoves or gas log fireplaces,please keep in mind: o If you alter the firebox of a fireplace,it must be converted to gas logs or removed. o If a woodstove is moved,it must be removed or replaced with a department certified woodstove. Attainment Area in Pitkin County New residential buildings in this area may have one wood burning fireplace and one gas log or certified woodstove. If there is no fireplace,you may have either 2 gas log fireplaces or 2 certified woodstoves or 1 each. Buildings may also have an unlimited number of decorative gas appliances. Remodeling or an addition to an existing building in the attainment areas • If the building has 2 or more fireplaces or woodstoves,the only devices you can add are decorative gas appliances. • If you have 1 fireplace or woodstove,you may add 1 gas log or certified woodstove and an unlimited number of decorative gas appliances • If a building has more than 2 fireplaces or woodstoves:if one is affected by a remodel, it must be removed • If a building has on 1 or 2 fireplaces,woodstoves or gas log appliances,please keep in mind: o If a woodstove is moved,it must be removed or replaced with a department certified device. o If you alter the firebox of a fireplace,and already have another fireplace,it must be converted to gas log Non residential buildngs(which include commercial buildings,restaurants,lodges,public buildings,and hotels)in the attainment area of Pitkin County are allowed to have gas appliances. RECEIVED G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc 10/29/2020 over ASPEN BUILDING DEPARTMENT Isokern® BVETTOT" B-Vent Gas Fireplaces and Chimney System Installation, Operation, Maintenance and Owner's Manual Isokern BVETTO Models 80B36 & 80B46 A PRODUCT OF EARTHCORE'R' INDUSTRIES, LLC IMPORTANT: This manual contains assembly rules, installation steps and guidelines, and use and maintenance in- structions for Isokern B-VENT gas appliances (BVETTO).This manual must become the property of and be reviewed by all current and future users of this product. It is the responsibility of the distributor, general contractor and the installer of this product that the instructions in this manual are followed exactly and,further that the allowed gas log appliance used in this product be installed in strict accordance with the gas log manufacturer's listing and explicit installation and operation instructions. INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference Be Sure to Read Entire Manual Before Beginning Construction. Contents of this manual may change without prior notification. Do not install the BVETTO B-Vent Gas Fireplace in a AWARNING: manufactured home or mobile home or recreational FIRE OR EXPLOSION HAZARD vehicle. Failure to follow safety warning exactly could result in serious injury, death, or property damage. — This appliance complies with National Safety and is tested and listed to ANSI Z21.50 - 2014 as — Do not store or use gasoline or other vented gas fireplaces. flammable vapors and liquids in the vicinity — Installation must conform to local codes. Check of this or any other appliance. local codes prior to installation. In the absence of local codes, installation must conform with — WHAT TO DO IF YOU SMELL GAS current National Fuel Gas Code,ANSI Z223.1. • Do not try to light any appliance. • Leave the building immediately. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's PFS Report No. 09-79 instructions. SAP No. 506022-03 • If you cannot reach your gas supplier, call USA: ANSI 2.2 2 -2014 Canadian: CSA .22-2014 the fire department. — Installation and service must be performed PFs+ Issued: November 2018 by a qualified installer, service agency or the Revision: 006 gas supplier. US ©2017 Earthcore Industries, LLC THESE FIREPLACES ARE DESIGNED for USE with: CEIVEt) PROPANE (LP) or NATURAL GAS (NG), ONLY 10/29/2020 THIS MANUAL CAN ONLY BE REPRODUCED IN ITS ENTIRETY ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 Table of Contents General Information 3 B-Vent Metal Chimney Installation 21 - 22 Safety Instructions 4- 5 Firebrick Installation 23 BVETTO B-Vent Series 36" Drawing 6 Flush Wall Finish Detail 24 Component List - BVETTO B-Vent Series 36"..7 Clearance to Combustible Trim 25 BVETTO B-Vent Series 46" Drawing 8 ISOKERN Gas Log Set - Component List - BVETTO B-Vent Series 46"..9 General Information 26 Burner Parts List 27 Required Clearance to Combustibles 10 Wiring Diagrams 28 Burner Installation 29-31 Calculating Flooring Loads 11 Log Set Installation 32 Installing/Replacing Batteries 33 Rough Framing Dimensions 12 Lighting Instructions 34-35 Remote Operations 36 General Assembly Instructions 13 Cleaning&Servicing 37 Troubleshooting 38 Assembly Instructions - BVETTO B-Vent Series 14 - 18 ECODAMPER System 39 Installation 40 B-Vent Metal Chimney Installation- General Information 19 Registration Card 43 B-Vent Metal Chimney Components 20 Warranty 44 BVETTO Rating Label ISOKERN BVETTO B-VENT GAS FIREPLACE:MODELS 301336 AND 80646 EARTHCDRE INDUSTRIES,INC. JACKSD NV ILLS FL 32256 PF- USTED VENTED DC CANADIA PER N 22150 2014 BV MODELe � US AND CANADIAN CSA2Z6-Z019 ❑80636 ❑8064fi VJ NOT FOR USE WRH SOLID FUEL - PFS REPORT NO.09-79 SERIAL NO: SUITABLE FOR USE WITH PROPANE ILPI OR NATURAL GAS,SEE GAS IDENTIFYING TAG ON BURNER 0 IBV36 MODEL e80B36 PROPANE ILPI BTU MIN:22,000;BTU MAX:50,000 01 BV36 MODEL o 801336 NATURAL GASINGI BTU MIN:21,000;BTU MAX:65,000 IBV46 MODEL o 801346 PROPANE ILPI BTU MIN:3,000;BTU MAX:60,000 0 IBV46 MODEL e 801346 NATURAL GAS I NG I BTU MIN:22,000;BTU MAX:75,000 ^Soo Bomb,Rating Plate For Additional Information MANIFOLD PRESSURE:PROPANE ILPI:10"WATER COLUMN;NATURAL GAS:3.5"WATER COLUMN MINIMUM PERMISSIBLE GAS SUPPLY PRESSURE FR PURPOSE OF INPUT ADJUSTMENT: PROPANE ILPI:11"WATER COLUMN/NATURAL GAS:5"WATER COLUMN CLEARANCE TO COMBUSTIBLES: f ELECTRICAL RATING: UNIT:ELECTRONIC UNIT FRONT AND SIDES =Oin 1 PH UNIT REAR =15in. 60mm 60 HZ COMBUSTIBLE SHEATHING ABOVE OPENING TOP =bin. 205mm SHEATHING OR TRIM TO OPENING SIDES =bin. 205mm 120 VOLTS MANTLE ABOVE OPENING =12in. 305mm LESS THAN 5 AMPS INSULATION FROM FIREBOX =3in. 75mm RECEIVED -CAUTION.THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN THE AFTER-MARKET.PERMANENTLY LOCATED.MANUFACTURED HOME{USA DNLYI OR MOBILE HOME.WHERE NOT PROHIBITED BY LOCAL CODES. SEE OWNERS MANUAL FOR DETAILS-THIS APPLIANCE IS NOT CDNVERTIBLE FOR USE WITH OTHER GASES,UNLESS A CERTIFIED KIT IS USED: (� T a3pliarne must be installed ina�:,:=-a with local WORD,8any if none,folUw the current ANSIZ222,O/NFPA 54 or CSA B149.1 10/29/2020 2 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace General Information BVETTO Models 80B36 and 80B46 are tested and fireplace operation. Check local codes for combustion air listed by PFS Corp., USA Report No. 09-79 to ANSI requirements. Z21.50 - 2014 and Canadian Standard CSA 2.22 - 2014. Each of these topics will be covered in detail The BVETTO models are top-vented, gas only fireplaces throughout this manual. Special attention must be given that are listed for use only with the ISOKERN Gas Log to each topic as the installation progresses. appliance listed in this installation manual. These gas The installation of the BVETTO must conform with appliances come with a gas control valve that includes local codes or, in the absence of local codes, with the an automatic shut-off switch.The gas valve is available in current National Fuel Gas Code, ANSI-Z223.1/NFPA 54 a millivolt remote control pilot assembly. or the current Natural Gas and Propane Installation Code, The exhaust flue gases are to be vented through CSA B149.1. the top of the unit with listed B-Vent piping. A ten inch (10") diameter, double wall B-Venting system and a listed Seismic Code Specifications vent cap are not supplied but are required for proper If installation of the Isokern Firebox is to be installed in operation of all BVETTO Models, 36 and 46. See venting an area with Seismic Codes please follow these instruc- instructions on pages 19-22. tions. Four No.4 ASTM A615 Grade 40 minimum,vertical reinforcing bars, 2 on each side of the fine box running WARNING: This gas appliance must not be connected from mid-height (where the tapered section of the box to a chimney flue servicing a solid fuel burning appliance. begins) of the structure to approximately 4 inches into the concrete slab(for anchorage). Intended Use Statement The BVETTO is intended to burn propane (LP) gas or natural gas (NG), only.This appliance is not intended to be used as a primary source of heat. The BVETTO and its approved components are safe when installed according to this installation manual and when operated as recommended by the manufacturer. Unless you use Earthcore Industries, LLC approved components tested for this appliance, you may cause a fire hazard or serious injury. Before you begin the installation of this appliance, read these instructions completely. Earthcore Industries, LLC disclaims any responsibility for the following actions: 1. Modification of the appliance or any of its components. 2. Use of any component part not approved by Earthcore Industries in combination with this appliance. 3. Installation or operation in a manner other than in- structed in this manual. 4. Burning of anything (solid fuel) other than the listed Important: The top plate of the firebox is not meant to gas log unit and the type of gas approved for use in this be used as a structural support. Please consult structural gas appliance. engineer for structural support of any veneer bearing weight on the Isokern top plate. The most important areas of concern with the Note: Do not scale drawings. Illustrations in this manual installation of the top venting BVETTO are clearance to are not to scale and are intended to show "typical" combustible materials, proper assembly of component parts, load carrying capacity of underlying floor system, installations. height of chimney system, hearth extensions and the Nominal dimensions are given for design and framing techniques employed in applying finishing materials to reference only, since actual installations to job specific design preferences. Alwa �it the wall surrounding the BVETTO. Combustion air inlet stated minimum clearances to combus i aterlas. kits though not required for the BVETTO may help improve Do not violate any specific installation requi i 'y �/2020 3 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 Safety Instructions WARNING: This product contains or generates 4. For propane (LP) use do not place propane supply chemicals known to the state of California to cause tank(s) inside any structure. Locate propane supply cancer or birth defects or other reproductive harm. tank(s) outdoors.To prevent performance problems, do not use propane fuel tank of less than 100 lbs. capacity. IMPORTANT: Read this owner's manual carefully and completely before trying to assemble, operate or 5. Do not install the BVETTO B-Vent Gas Fireplace in a service this fireplace. Improper use of this fireplace manufactured home or mobile home or recreational can cause serious injury or death from fire, burns, vehicle. explosions and carbon monoxide poisoning. 6.This fireplace reaches high temperature. Keep children DANGER: CARBON MONOXIDE POISONING MAY and adults away from hot surfaces to avoid burns or LEAD TO DEATH! clothing ignition. Fireplace will remain hot for a time after This fireplace is a vented product and will not produce shutdown.Allow surfaces to cool before touching. any gas leakage into your home if properly installed by a qualified service person. If this unit is not properly 7.Turn the BVETTO B-Vent Fireplace off and allow to cool installed by a qualified service person, gas leakage may before servicing. Always shut off any electricity and gas occur. to the BVETTO B-Vent Fireplace while working on it. Only Propane (LP) gas and natural gas (NG) are both a qualified service person should install, service or repair colorless and odorless gases. An odor-making agent is this fireplace. Have your fireplace inspected annually by a added to each of these gases to help you detect a gas qualified service person. leak. However, the odor added to these gases can fade and gas may be present even though no odor exists. 8. It is imperative that the unit's control areas, burners Carbon Monoxide Poisoning: Early signs of carbon and circulation air passages be kept clean. monoxide poisoning resemble flu symptoms, including headaches, dizziness or nausea. If you have these signs 9. Venting system should be inspected annually by a the fireplace may not have been installed properly, get qualified service person. If needed have venting system fresh air at once! Have the fireplace inspected and cleaned or repaired. serviced by a qualified service person or your gas supplier. Some people are more affected by carbon monoxide 10. Keep all combustible material, gasoline and other than others.These include pregnant women, people with flammable liquids at a safe distance from the fireplace. heart or lung diseases or anemia, people at high altitude Do not use the fireplace where these items are used or or under the influence of alcohol. Earthcore Industries stored. Decorations,clothing and other such combustible strongly recommends the use of a carbon monoxide items should not be placed on the fireplace. detector/alarm device wherever gas fired appliances are in use. 11. Do not use the BVETTO B-Vent Series Fireplace to All parties either involved in or associated with the cook food or burn paper or other objects. installation, service and use of this fireplace must read this entire manual. Keep this manual for reference and as 12. Do not use any solid fuels - wood, coal, paper, a guide book to safe operation of this fireplace. cardboard, etc. - in this fireplace. Use only the gas type listed on the fireplace's gas log label. WARNING:This unit is not for use with solid fuel. 14. Keep all insulation and vapor barriers a minimum 1.Always check local building codes governing fireplaces of three inches (3") away from all BVETTO B-Vent and and fireplace installations. The BVETTO B-Vent Series chimney components. installation must comply with all local, regional, state and national codes and regulations. 15.This American Gas Association fact sheet provides an overview of the requirements for the electrical bonding 2.The BVETTO B-Vent Series fireplaces are listed for use of fuel gas piping systems to the electrical grounding with the decorative gas log appliance listed in this system based on ANSI Z223.1/NFPA 54, National Fuel manual only. Gas Code - 2015 (NFGC). The bonding requirements in previous code editions, in local jurisdictions or in specific 3. This appliance is only for use with the type of gas situations, may differ. indicated on the rating plate.This appliance can be field\/ED converted for use with other gases with Propane (LP) or 16. Do not pack or fill required air space I I. �/ Natural Gas (NG). or other material. No material is allowed in these spaces. 10/29/2020 4 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace Safety Instructions 17. Never install a BVETTO B-Vent Series component, 29. Do not nail or screw into the isokem fireplace, chimney component or accessory that has visible or which includes firebox or smoke dome components suspected physical damage as a result of handling or unless attaching the anchor plate for the metal transportation. These items should be inspected by a flue system. This may alter the integrity of the qualified representative to ensure safe condition. When fireplace and cause a house fire.THIS WILL VOID THE in doubt, consult your local supplier. WARRANTY OF THE FIREPLACE. 18. Do not alter or modify the BVETTO B-Vent Series, 30. Never spray or apply any type of sealer, insulation or venting components under any circumstances. other materials to the fireplace. Modification or alteration of the venting components may void manufacturer's warranty, listings and approvals. 19. Do not use a fireplace blower insert, heat exchanger or any other product not specified by the manufacturer herein for use with this fireplace. 20. Do not use any BVETTO B-Vent Series appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 21.The BVETTO B-Vent Series is not intended to heat an entire home or to be used as a heat source. 22. Children and adults should be alerted to the hazards of high surface temperature and should stay away from this appliance to avoid burns or clothing ignition. 23. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental \/ contact burns.A physical barrier is recommended if there are at-risk individuals in the house.To restrict access to the fireplace, install a adjustable safety gate to keep toddlers, young children and other at-risk individuals out of the room and away from hot surfaces. 41411111144111111441114?1/1 24. Clothing or flammable material should not be placed 1 on or near the appliance. 25. Due to high temperatures, the appliance should 11111111" be located out of traffic and away from furniture and 1 / draperies. I. 28. Installation and repair should be done by a qualified I 11111111r service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etcetera. IrIP* I/ It is imperative that control compartments, burners, and ^� circulating air passageways of the appliance be kept ��Opt. )14 clean. oie" i•, il + II Er) 11 /2 "I 2020 5 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 BVETTO B-Vent Series 36" (80B36) 221/2"-1," 25 1/4" l A illi 1 1 16" J 36 3/4" High Temp Lintel 16" i711/4" 711/4" limmil i A LS _ II 361/8" El MI31 '/2" 31 Y2" 34 1/2" 4— II i 101/2" 111 1 , 43 alNote:These are inside rough dimensions 5" Front View before firebrick Side View Uses 10"Metal-Fab or DuraVentType B Gas Vent Chimney. r 10 3/4n -4-- \ 271/4 25 '/4" 25 '/4" 14" Flue Outlet -0-22 ' "H 361/8" ► 43„ ► Plan View Top View RECEIVED 10/29/2020 6 ASPEN BUILDING DEPARTMENT Earthcore Industries = BVETTO B-Vent Gas Fireplace Component List - BVETTO B-Vent Series 36" (80B36) Component Part# Description Component Part# Description rz5v." \/ V t0v. Isokern BVETTO 36S Isokern BVETTO Base Rate 0 Top Plate /43 �\/434" V 4" 4" 12 Isokern BVETTO 11 Isokern BVETTO Smoke Dome(QTY.2) 16. Smoke Dome(QTY.2) 16. 42,Y.� j 32vzNN/ j 2514 A 01/2" 34 Isokern BVETTO Isokern BVETTC te" Badkwall(QTY.3)* Side Sloping(QTY.4) V i � *NOTE: One additional backwall and two additional sidewalls 2514 �A can be added to obtain an opening of 42"tall before brick ��II Isokern BVETTO is installed, as well as,Two additional badkwalls and four tovz * additional sidewalls can be added to obtain an opening of 52Yi' I Sidewall(QTY 6) tall before brick is installed.To obtain this height the additional pieces will need to be ordered in addition to the 80B36 fireplace kit. RECEIVED 10/29/2020 7 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 BVETTO B-Vent Series 46" (80B46) 33 1/2"-I.- 25 1/4„ • 16" l36 3/a" ii High Temp 1 Lintel 16" i 71 Ya" 71 1/4" • IImmi • A AO 31 31 1/2" 341/2" 10 Y2" II 53" p l Note:These are inside rough A 5" dimensions Front View before firebrick Side View Uses 10"Metal-Fab or DuraVent Type B Gas Vent Chimney. 0 10 3/4" 37 1/a" 25'/a" /...._ 251/4" I 14" Flue Outlet F.- 331/z" . 47 1/8" I. • 53" • Plan View Top View RECEIVED 10/29/2020 8 ASPEN BUILDING DEPARTMENT Earthcore Industries = BVETTO B-Vent Gas Fireplace Component List - BVETTO B-Vent Series 46" (80B46) Component Part# Description Component Part# Description rz5v." N/ V tay. Isokern BVETTO Base Rate Isokern BVETTO /53 �\0 Top Plate /43i" V 4" 4" I J Isokern BVETTO 11 Isokern BVETTO Smoke Dome(QTY.2) 16. Smoke Dome(QTY.2) 16. 42,Y.� 1 Sz,Y.N/ i 2514" ,, i ,ovs ,e" 34 Isokern BVETTO Isokern BVETTO Side Sloping(QTY.4) Badkwall(QTY.3)* ao- V i >B- *NOTE: One additional badkwall and two additional sidewalls 25 Y`�illA can be added to obtain an opening of 42"tall before brick �I/ Isokern BVETTO is installed, as well as,Two additional badkwalls and four tovz Sidewall(QTY 6)* additional sidewalls can be added to obtain an opening of 521/2' rig tall before brick is installed.To obtain this height the additional pieces will need to be ordered in addition to the 80B46 fireplace kit. RECEIVED 10/29/2020 9 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 Required Clearance to Combustibles The BVETTO fireplaces and chimney systems are tested and listed for installation with "clearance to _....444410 combustibles" as follows: Zero inch (0") clearance to the combustible floor; (Isokern Base Plate must be used) Zero inch (0") clearance at the Isokern firebox sides and front and smoke dome sides and front. One and one half inches (1-1/2") clearance at the -` Isokern firebox back wall and smoke dome back wall. ��,` One inch (1 ") minimum air space to combustibles at all B-Vent double wall chimney components' outer layer. ;,; When installing on a combustible floor system 14011iiiiikii.:--- the front of the fireplace must be covered with a non- ' /1 --.10• '" combustible hearth extension material set tight against 0 ► the fireplace front and extending at least twenty inches ,I ` (20") out from the finished front of the fireplace and at least twelve inches(12") beyond the finished sides of the fireplace opening. IMPORTANT: "Combustibles" are defined as "normal construction materials" and considered to be: wood framing materials, particle board, mill board, plywood paneling, plywood subflooring and wood flooring. �\�/ CAUTION: Maintain three inches (3") clearance to �` insulation and vapor barriers from all firebox, smoke III dome and B-Vent flue components' outer layer. NII�\II �1�\ EXCEPTION: If insulation is used in walls surrounding �II�'II �// I�/ the fireplace, insulation may be installed behind sheathing ,// ; of gypsum board, plywood, particle board or other rigid, ,/ fire rated material on the side facing the Isokern. The •7 facing material cannot be within 1 1/2" to the fireplace sidewalls. NOTES: 1. The fireplaces must sit upon a support designed to bear the total installed weight of the fireplace. 2. All BVETTO installations will result in the minimum finished fire brick floor of the firebox being at least four \ and one half inches (4-1/2") above the combustible floor system. Never place a BVETTO on a combustible floor I 1 without the base plate. illi Min. • ' I ,1�CI —II_I� i A14 •=i1� • • •— Iif COMBUSTIBLE FRAMING / 0" i . 0,. Min. iiMin. AA '' --- —— VED a..sori.F...- FIGURE 1 FIGURE 2 10/29/2020 10 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace Calculating Flooring Loads Floor framing for BVETTO installation will need to be designed and built to accept substantial dead loads spread over a relative small floor area. (Figure 3) The following weights and sizes can be used to calculate loading. It is the contractor's responsibility to provide adequate floor system load capacity. BVETTO Weights and Load Calculations Total dead load amounts include (but are not necessarily limited to) the following items and their corresponding weight estimates as listed below: 1. Isokern unit model weights: a. BVETTO-46: 1400 lb b. BVETTO-36: 1200 lb 2.Approximate weight of log set: 100 lb. 3. Fire brick and Adhesive: 350 lbs. - 1800 lbs. depending on brick size and pattern ' 4. Facing material: per general contractor Hearth Extension 5. B-Vent metal flue: per manufacturer (non-combustible) The floor area for each model is as follows: ' BVETTO-46 @ 53" x 25.25" = 9.30 sq. ft. BVETTO-36 @ 43" x 25.25" = 754 sq.ft. �// (///,� Earthcore is not responsible for structural floor support details for this fireplace system. Unless otherwise noted all floor framing drawings in this manual N "' are merely illustrations to indicate the presence of an Combustible underlying floor system. Floor System Consult your local structural engineer for proper floor (non-insulated) system design, sizing and specifications. FIGURE 3 RECEIVED 10/29/2020 11 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace t}'20f8 Rough Framing Dimensions • Typical Installation Framing Dimensions deP ® BVETTO Width Height Depth r ® A B C Model 36 44" 72,'83", 93" 26 3/4" ® Model 46 54" 72,'83", 93" 26 3/a" Frame .40 Notes: opening 1. "B" includes the 3" thick base plate. t 2. "Raised hearth" requires additional rough opening height at "B" equal to the height of the raised hearth detail. 3. Rough framing dimension for width "A" allows for the 1/2" for each side to build fireplace in the space.There is ��` 0" required clearance at the sides of the Fireplace. 4. Rough framing dimension for depth "C" allows for the open Famed ne Y required 1-1/2" clearance at the back of the Fireplace. FIGURE 4 5. Opening height of 83" requires minimum 9' flue; 93" height requires minimum 12' flue. -_:H MMM:MiMrilllii M " Corner Installation Framing Dimensions c I B ' BVETTO A B C D ' Model 36 44" 49" 32" 70" o Model 46 54" 59" 39" 77" A / Note:The following chart of plan dimensions is intended Ito aid in the positioning of an BVETTO in a corner . condition. r I A FIGURE 5 RECEIVED 10/29/2020 12 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace General Assembly Instructions When beginning the assembly process, mix the Earthcore Adhesive with clean water to a smooth, workable texture (without lumps or dry pockets) of a "toothpaste" consistency. This mixture is suitable for application onto Isokern components by using a masonry grout bag supplied with the unit. Attention should be paid that the Adhesive mixture is not too thin or runny, as this will not allow the Adhesive to reach its maximum bonding strength. Mark out the position of the base plate on the supporting floor system. Apply a thin layer of Earthcore Earthcore Adhesive to the area and set base plate in the Adhesive. Adhesive (Figure 6) Earthcore Adhesive is then squeezed from a grout bag onto the contact surfaces of the Isokern components as FIGURE 6 they are fitted together. NOTE: It is important that a 1/2" bead of Adhesive is piped onto all the components' contact surfaces, about 1/2" in from all edges. (Figure 7) Earthcore Adhesive Earthcore When setting the next component onto the Adhered contact surface of the base plate, some Adhesive should Adhesive squeeze out along the face of the entire joint as a sign of complete and proper sealing of the joint. On broader contact surfaces it is advisable to apply several additional 1/2" beads of the Earthcore Adhesive to the area to assure proper sealing of the joint. Properly Adhered firebox and smoke dome assembly requires approximately 100 pounds (dry measure) of Earthcore Adhesive. Leveling and Aligning Components: FIGURE 7 Be sure to assemble all Isokern components level and flush with adjoining components. Earthcore Adhesive is not intended to create a Adhesive joint of any thickness for leveling purposes. Therefore, leveling and alignment adjustments are made by the use of small plastic shims supplied with the unit. (Figure 8) The shims can be inserted under a component to level and align it with adjacent Isokern components. Be sure to re-grout any and all gaps resulting from shim insertion to maintain components to full bearing. Broken Components: Components can be repaired by using Earthcore Adhesive along the break line as the component is set into place.Components broken into multiple small pieces \ 41111111111141111111444 11.°1° should be discarded and replaced. IMPORTANT: 1.Do not mix Earthcore Adhesive with anti-freeze agents. 2.The maximum recommended Adhesive joint thickness R EMO/ED at Isokem components is 1/47 10/29/2020 13 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 Assembly Instructions - BVETTO B-Vent Series • The following assembly instructions identify the • parts by name, part number and the placement of each part in the assembly process. NOTE:At all component placement, be sure to Adhesive Base Plate: all contact surfaces with Earthcore Adhesive. Check for 36": Part 21 complete sealing of each contact joint while assembly • 46": Part 23 progresses. 1. Set the base plates in a full bed of Earthcore Adhesive on a level support surface. See page 11 for supporting floor system. (Figure 9). Do not set the base plate so Earthcore that it is in span. Adhesive Flush Hearth: — If the design preference is for a "flush hearth" the base FIGURE 9 plate can be omitted from the assembly and the firebox walls built directly on a minimum 4" concrete support slab.The fire brick floor of the firebox is then set directly II to the concrete support slab. This makes the fireplace finished fire brick floor approximately one and one-half ,\/ inches (1-1/2") above the top of the concrete support slab.The noncombustible hearth material will butt tight 1 101 iup against the fire brick floor. (Figure 10) I, ' Raised Hearth: I �' If the design preference is fora raised hearth (floor I '% II / of the fireplace elevated above the room's floor), then the base plate can be set on a noncombustible platform FIGURE 10 II / \/ that is built up to the desired raised hearth height on the II I I concrete support slab. (Figure 11) 1 When calculating raised hearth height be sure to Flush Hearth 4111141111141114 '�/I� allow for the three inch (3") thick base plate plus the one on Concrete ` and one half inch (1-1/2") thick fire brick floor in addition Foundations Only ` to the height of the platform. For all "raised hearth" construction where concrete 1 blocks are used to create the raised platform, it is necessary to use the base plate. Be sure to Adhesive # 5 the concrete block platform together. CMU used for base plate support should be rated ASTM 90. Whether a flush hearth or a raised hearth is installed, the combustible floor in front of the fireplace must be 1. jril covered with a noncombustible hearth extension set tight against the fireplace front and extending at least 20 inches out from the finished fireplace and at least 12 .4 inches beyond the finished sides of the fireplace opening. I / WARNING: "Flush hearth" installations are possible ``I / only where the BVETTO support is a concrete slab 111111111114141144% \ / \� without any wood underpinning as the base plate FIGURE 11 ' is omitted. Never place a BVETTO on a combustible \ '10I it floor without the base plate. Raised hearth ♦ RECEI for wood or 1 D concrete installs 10/29/2020 14 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace Assembly Instructions - BVETTO B-Vent Series 2. Set the first course of the firebox side walls and back Earthcore walls into place. (Figure 12-13) O1 Adhesive NOTE: It may be convenient to dry set the first course of II side walls and back walls into place on the Isokern base I2b Part#20 plate and then trace their position on the base plate with a pencil. After outlining the dry set pieces, remove them and apply Earthcore Adhesive to the areas traced on the base plate where the side walls and back wall are to sit. By doing this, the first layer of wall components can be set directly into Adhesive already applied to the proper areas on the base plate. 3. It is required that the two supplied high temperature wires be routed from the inside of the BVETTO as follows: Once the lowest, left hand side wall firebox FIGURE 12 component is set in place (left, when facing the fireplace) drill a 1/4" - 3/8" dia. hole in the inner face of this side wall located four to six inches (4" -6") out from the back Earthcore wall of the BVETTO and at three to four inches (3" - 4") Adhesive above the BVETTO base plate. (Figure 14) Backwall: This drill hole must intersect the hollow core of the '`. 36": Part 25 BVETTO firebox side wall. 46": Part 31 Feed the two lengths of high temperature wire from the inside of the BVETTO firebox through the drilled hole Part#20 and into hollow space of the firebox side wall. Bring the two lengths of wire up and out through the top of the \ side wall component (Figure 14). NOTE: For Seismic Installation - With the Seismic installation the opening in the sidewalls are used to anchor the Isokern Fireplace to the floor with rebarb and Part#20 backfilled with concrete. The high tempertaure wires will need to be run outside of the Isokern unit and not through the openings in the sidewall. The wires will be run through the bottom course of the sidewall and out to the side of the Isokern Fireplace. FIGURE 13 Another 1/4" hole should be drilled in the first course of side sloping to attach to the high temperature wires to the high temp lintel for the High Temperature switch. 1.4 3. Continue assembly of the consecutive courses of the firebox side wall and back wall.Apply Adhesive to the top 0 \ \ of each layer of wall components, set the next course above into place. Be sure to Adhesive all vertical joints of the side wall to back wall connection when setting each component to its mate. (Figure 15) Look for some Adhesive to squeeze out along the joints of all contact surfaces as a sign that the joint is thoroughly sealed with the approved Adhesive. IVED 1 i 20 15 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 Assembly Instructions - BVETTO B-Vent Series Backwall: 4. When all of the firebox sidewall and backwall 36": Part 25 S1components are set, check the top surface of the firebox 46": Part 31 for level. If necessary, adjust the top surface of the box assembly for level by inserting a shim supplied with the ; 1 unit between the lowest wall component and the top 11 io I surface of the base plate. 10#20 Any gap created under the wall components during 110 the Shim leveling process must be filled with Earthcore IO Adhesive to fill bearing against the base plate. 5. Begin the smoke dome assembly by setting the rear bottom smoke dome component on top of the firebox back wall assembly in a bed of Earthcore Adhesive.The smoke dome component should sit flush with the back FIGURE ::....„,,,iside of the firebox assembly. (Figure 16) p Then set the front bottom smoke dome component across the firebox opening so that the smoke dome piece spans the firebox opening and is flush with the front of Smoke Dome: the firebox. 36": Part#11 IIIIISso. 6. Position the smoke dome's sloping sidewalls at each 46": Part#13 end of the bottom smoke dome components. The sloping sidewalls fit in between the front and rear smoke dome components and also fit into the 4 i haunches at the ends of the front and rear smoke dome ' components. 110" The smoke dome sloping sidewalls have a beveled I- bottom edge so that they will sit tight onto the flat top of 116. O os the firebox side walls. I7. Set the upper course of front and rear smoke dome components directly on top of and aligned with the bottom front and bottom rear smoke dome components III%IIIIIIIIIIIIIIIIII that are already in place. FIGURE 1617 I Set the two upper smoke dome sloping sidewalls into position, one at each end of the upper front and rear smoke dome components. (Figure 17) Top Plate: 8.Set the top plate into position and adhere on top of the 36": Part#36 smoke dome wall assembly. 46": Part#77 One side of the top plate shows a thickened center. This side is the bottom face. Side Sloping: The flue hole in the top plate is centered in the 36": Part#34 smoke dome from side to side but is offset from front to 9.44 t 46": Part#34 back, the center being ten and three-fourths inches (10 ' 3/a") from the back of the firebox. (Figure17) 11111. 01. 9.The high temp lintel,as supplied, is forty five inches(45") ' long and fits the BVETTO models 36&46. Field cut the high templintel equally at theperforated lines as required for the '� %/ q Y q 36" unit.This will ensure the limit switch and micro-switch are located in the proper position on the lintel. Connect the two (2) leads from the h. ED wires to the thermocouple junction bloc page 29). FIGURE 17 10/29/2020 16 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace Assembly Instructions - BVETTO B-Vent Series Measure and locate the centerline of the fireplace open- 2 HighTemperature P p Wires "ing.Align notch at the front of the lintel to the centerline of ,,.7-1- the fireplace. Install lintel using 1 1/2" masonry screws. ;„,,» HighTemperature Limit Switch NOTE: The limit switch and microswitch are already sup- , plied and mounted in the BVETTO high temp lintel compo- nent. Connect the two high temperature wires (coming out " the top of the BVETTO left hand firebox side wall)to the two high temperature wires that are attached to the limit switch Tab to be bent upward to stand vertical with ceramic wire nuts. (both sides) FIGURE 18 The small tab near damper lever should be bent upward �` to stand vertical.This protects wires passing through the Limit Switch harness. U � Front WARNING: Do not bypass the high temperature limit Alternate wire Fadng switch. Install downdraft diverter at the top plate. (Figure location 20) Orient assembly such that the wire cable is toward the front of the fireplace opening. Loosen screws on the cable clamp and loop between the two washers at the end of the handle asembly. NOTE: Wire clamp should be approximately 4" from the Iliiiiill%11111111111?1011.111111 washers.Tighten lock nuts on the handle if necessary. Pull , 1 ' cable to close the damper and adjust the length of wire 4 /#cable by swinging the handle between open and close po- sitions. When in the open position, the damper should be ' 41 rotated a full 90 degrees from the closed position. Retighten , Ill screws on the cable clamp and remove excess cable. 110111111 The high temp lintel fits horizontally up toward the bot- 114%1tom of the smoke dome.The adjoining short leg of the hightemp lintel fits up against the bottom of the smoke domecomponent. (Figure 19) I The high temp lintel has 4 pilot holes for the screw Metal Canopyt FIGURE 19 placement. Attach the high temp lintel flush against the front face of the smoke dome with 4 mounting screws driv- en into the face of the BVETTO smoke dome. Ti- Any excess wire draped between the high temp lintel and the left hand firebox sidewall should be neatly tucked into the hollow core of the left hand sidewall. Excess wire should not be visible below the canopy bottom. Smoke Dome Component NOTE:The 2 high temperature wires inside of the BVETTO firebox will connect to the appropriate contacts found on �� the gas log assembly during the installation of the gas log 11 set. rm1 (1111, ,,, hl rio,.....„, HighTemperature Limit Switch MITA Metal Canopy D 19 20 17 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 Access Modification - Combustion Air Kits, Gas & Electrical Line Feed 4" Combustion air inlet kits are not required by The combustion air kit consist of a sliding stainless steel Earthcore but may help improve fireplace operation or black access door affixed to a four inch (4") in diameter in homes tightly sealed and with other ventilating stainless steel sleeve approximately twelve inches (12") appliances installed. (Figures 21 & 22) The following long. An exterior vent with dress plate, weather hood and is a general representation of a combustion air kit. rodent prevention screen of a maximum one-quarter inch (1/4")wire mesh and ten feet(10')of hose completes the kit. Flex DuctTo Fireplace The access door is fitted into the front 1/3 of the side (All Parts Noncombustible) wall.The twelve inch(12")long sleeve can be introduced into the firebox side wall by core drilling an appropriately sized hole at the selected firebox location. Keep the top of the access hole no more than six inches (6") above the finished Exterior firebrick floor.The hole size should allow for a one-quarter � q Wall inch (1/4") mortar joint around the air access sleeve for heat thlllllllllllllft expansion. Do not install in the rear of the firebox because iI sparks will be blown into room. The sleeve passes through the firebox side wall and must be connected to a UL Listed Air Duct pipe that leads FIGURE 21 to the source for outside combustion air, as directly as Exterior Air Vent possible from the fireplace. It is recommended that the duct With Dress Plate terminate as close to the fireplace opening as possible but must terminate a minimum of 3 feet below the chimney cap level.Air inlet ducts shall not terminate in attic spaces. If the installation is to be longer than ten feet(10'), then the six inch (6") adapter will be needed. This adapter will attach to the existing four inch (4") sleeve outside of the unit. e The six inch adapter includes an additional twenty feet of 6" ® flex hose, for a maximum run of thirty feet(30'). WARNING: Do not use combustible duct material. Avoid installing a combustion air inlet where the opening could be ' blocked by snow, bushes or other obstacles. Air inlet ducts shall not terminate in attic, basement or garage spaces. , 11r1 \ Gas Line Feed For a fireplace having the provision for installation of a gas `114111� 1 ` pipe, the provision is intended only for connection to a Placement of decorative gas appliance. tailsliok Bic Conduit tail Below) , CAUTION: When using the decorative appliance, the fireplace damper must be set in the fully open position. Gas CAUTION: line for gas log sets used in the Isokern firebox can be routed All access holes must be through the side wall, bydrillingan appropriately sized hole FIGURE 22 grouted with mortar-after 9 line or conduit feed to seal using a masonry drill bit. (Figure 23) any gaps or cracks around line feed conduits Electrical Line Feed Should be routed through the BVETTO firebox side walls by drilling an appropriately sized hole using a masonry drill bit (Figure 61). Be sure to follow the gas log Appliance Fire Brick Side Manufacturer's explicit electrical line connection instructions for vented masonry fireplace installations. Gas line and electric line must be fed through separate access holes. Gas or Electric Conduit CAUTION:All access holes must be grout NOTE:Fill Any Gaps after line or conduit feed-to seal anygaps �/ Around Conduit with Mortar line feed conduits. (Figure 23) FIGURE23 10/29/2020 18 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace B-Vent Metal Chimney Installation - General Information The BVETTO Series Fireplaces are tested and listed or try to match with other products or use improvised for use with the specified factory-built metal B-Vent solutions. Chimney Systems. The design and installation require Install your Isokern fireplace as described in this that the system use the Metal-Fab Type B Gas Vent or installation manual and maintain all required clearances. the DuraVentType B Gas Vent Chimney Systems. Connect only one fireplace per chimney. Follow the fireplace safety manual for maximum efficiency and APPROVED MANUFACTURERS safety. Do not over fire. Any damage to the fireplace or Metal-Fab®(UL 441 & ULC S605)Type B Gas Vent chimney can possibly void the warranty. DuraVent®(UL 441 & ULC S605)Type B Gas Vent Do not burn wood, driftwood, plastic, or chemically treated wood such as railroad ties.They are corrosive to NOTE: The selected, approved chimney manufacturer your chimney system.THIS ISA GAS ONLY FIREPLACE. must provide the masonry anchor plate with down draft diverter designed to fit their flue system. (Figure 24) All chimneys and chimney liners must be installed in accordance with the manufacturer's installation A major cause of chimney related fires is instructions and under the terms of their listing for use with open faced fireplaces. failure to maintain required clearance (air spaces) to combustible material*. Minimum Refer to metal flue manufacturer for number clearance for 10" diameter air-cooled eco- of offsets, approved chimney shrouds, clearance to steel chimney is one (1) inches. It is of utmost combustibles and any information specific to that flue importance that this chimney is installed system. Only tested and listed chimney terminations only in accordance with these instructions. can be used on metal flue chimney systems. B-Vent Chimney is not designed for use on products that operate — at continuous temperatures in excess of 1000°F. IMPORTANT: Never fill any required clearance space with insulation or any other building materials surrounding the chimney. Exterior metal parts, with exception of the top portion of the chimney cap, can be painted with a high temperature rust proof paint. Wash the metal surface with a vinegar and water solution to remove any residue before painting. Painting the chimney will help to increase chimney life. Interior chimneys shall be enclosed where they extend through closets, storage areas, occupied spaces, or anywhere the surface of the chimney could be contacted by persons or combustible materials.The air space between the outer wall of the chimney and the enclosure shall not be less than 1 inches. Except for installation in one or two family dwellings, a factory built chimney that extends through any zone above that on which the connected appliance is located is to be provided with an enclosure having a fire resistance rating equal to or greater than that of the floor or roof assemblies through which it passes. In cold climates, chimneys mounted on an outside wall should be enclosed in a chase. Exterior chases reduce condensation and enhance draft. Proper planning for your B-Vent Chimney installation will result in greater safety, efficiency and convenience. RECEIVED must use only B-Vent Chimney parts and components to maintain a listed chimney system. Do not mix parts 10/29/2020 19 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace l}l2018 Metal-Fab B-Vent Components DuraVent B-Vent Components Component Part# Description Component Part# Description 1OM12 B-Vent 12'Length 1OM18 B-Vent 18'Length ` B-Vent 18'Length 1OM24 B-Vent 24'Length 1OM3 B-Vent 3'Length 1OM4 B-Vent 4'Length B-Vent 3'Length 1OM5 B-Vent 5'Length 10M12a B-Vent 12'Adjustable Length 10GV12A B-Vent 12'Adjustable Length 10M18A B-Vent 18'Adjustable Length elk 45 Deg Adjustable Elbow 45 Deg Adjustable Elbow kit B-Vent Draft Diverter -" B-Vent Draft Diverter 10MG= B-Vent Guy Ring B-Vent Firestop Support I' kR Mrf OM= B-Vent Standard Flashing = B-Vent Adjustable Flashing Lji 10Pv1FS B-Vent Firestop 01B-Vent Firestop B-Vent Storm Collar B-Vent Storm Collar B-Vent Flat Tall Cone Flashing == B-Vent FlatTall Cone Flashing Ec IVED B VentVent Cap/Termination II B-VentVen apgermina ion 10/29/2020 20 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace B-Vent Metal Chimney Installation 1.Mount Anchor Plate with down draft diverter:Chimneys IBV Anchor Plate for Isokern BVETTO fireplaces begin with an Anchor Plate with down draft diverter. It is important that the surface of the Isokern chimney 001,1,11111 has a level surface on which to attach the Anchor Plate. If the top of the Isokern does not have a level surface, then it will need to be modified accordingly. Center the Inswool blanket over Isokern Top Plate ISOWOOL hole and trace outline of hole with a pen or marker. Cut Ceramic a hole in the blanket to match the hole in the Isokern Fiber Blanket top plate. Center the Inswool blanket over the Isokern Top Plate flue opening, then center anchor plate over the Inswool blanket. Make sure nothing interferes with the \/ damper plate movement. IBV Firebox Secure the Anchor Plate with four (4) masonry anchors. (Figure 24) If the Anchor Plate with Damper is installed the damper should swing freely. When the chain is pulled down,the damper should close (horizontal position). When the chain is released (no weight on the chain), the damper should swing open (vertical position). To install the lintel hook, place the damper plate in the closed (horizontal) position. Determine and mark 11111111k46/1 the position of the lintel hook. The lintel hook should be mounted in a position so as to provide a small amount of I. tension in the spring attached to the chain. .• \' The tension is needed to prevent the damper plate I I from rattling when closed. Mount the lintel hook to I masonry with the screws provided. Do not obstruct oval openings in the anchor plate. I/ WARNING: Do not locate Anchor Plate with Down Draft FIGURE 24 Diverter in a location inaccessible for inspection, cleaning and servicing after installation. 2. Starting at the anchor plate, attach the first section of • B-Vent Pipe. It is acceptable to use screws to attach the B-Vent to the anchor plate. 1, suRELocTM K The B-Vent sections and components use the Metal- TAB Fab positive twist lock for interconnections. Align the ends of the vent, push together then twist section to lock in place. (Figure 25) No additional fasteners are required to assure a safe MINOV • installation. It is acceptable to apply screws at the joints LINE UP PIPE ENDS TWIST TO ENGAGE TWIST if local code requires, or at the installingcontractor's AND PUSH TOGETHER. LOCK AND DEPRESS q SURELOCKTM TAB TO option, provided that the screws do not penetrate the SECURE RPATENTE si;IONS flue. • NOTE: When installing B-Vent always align "Up" arrow away from appliance. Chimneys must be installed so that access is provided for inspection and cleaning. - c 9k • RECEIVED TO UNLOCK,SIMPLY BEND PULL PIPE APART OUT THE TAB AND UNTWIST = � 2 0 21 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 B-Vent Metal Chimney Installation 3.If the B-Vent must penetrate the ceiling between floors, cut a hole in the ceiling 2 inches larger than the outside diameter (OD) of the outer casing. The B-Vent is to be centered in this opening.When installed, check to make sure the one inch (25.4 mm) clearance to combustible has been maintained. MC CAP . - .- NOTE: The B-Vent type chimney system must be enclosed within a chase when installed in or passing STORM COLLAR through a living area where combustibles or people may �, I c ROOFING TO come in contact with it. This is important to prevent \, OVERLAP possible personal injury or fire hazard. FLASHING BASE ON HIGH SIDE 4. Continue with B-Vent penetrating the roof. MF FLASHING NOTE: For Canadian installations, use labeled ULC section, designated with Suffix G, on vent sections exposed to atmosphere. MAINTAIN 1'(25.4 mm) f WALL BAND-REQUIRED At the roof, the opening should be 2 inches (51 mm) CLEARANCE TO FOR EVERY FT. reater than the B-Vent OD. Above the roof, a flashin is COMBUSTIBLETHRU OF VENT HEIGIG HT g g JOIST AREA I• required to maintain the one inch (25.4 mm) clearance to r _ _ the combustibles of the roof. Installation of a storm collar 1 \_ allows water to drain over the flashing. FIRESTOP 5. Install the B-Vent cap (MC) onto the B-Vent. ARROWS ALWAYS UP POINPLIANCY EROR�� NOTE: See height of vents under "SAFETY': APPLIANCE FOR t g EACH SECTION \_/�/ A B-Vent Cap should be used on all installations to prevent back drafts and to keep out rain and debris. FIGURE 26 The vent must extend through a flashing, and should terminate with the lowest discharge opening no closer to the roof than the minimum height shown in the table below. These minimum heights may be used provided the vent is not less than 8' from any vertical wall. For installations not covered in table below, the lowest discharge opening of the vent cap should be at least 2' above the highest point where it passes through the roof. All gas vents extending above the roof more than 5 feet must be securely guyed or braced. Roof Pitch Minimum Height Flat to 7/12 (305 mm) 1.0 ft Over 7/12 to 8/12 (451 mm) 1.5 ft Over 8/12 to 9/12 (610 mm) 2.0 ft Over 9/12 to 10/12 (762 mm) 2.5 ft Over 10/12 to 11/12 (991 mm) 3.25 ft Over 11/12 to 12/12 (1218 mm) 4.0 ft Over 12/12 to 14/12 (1524 mm) 5.0 ft Over 14/12 to 16/12 (1829 mm) 6.0 ft Over 16/12 to 18/12 (2134 mm) 7.0 ft Over 18/12 to 20/12 (2286 mm) RECEIVED Over 20/12 to 21/12 (2438 mm) 10/29/2020 22 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace Firebrick Installation The manufacturer requires that the fireplace fireboxes be covers the 1/2" expansion gaps where both the floor lined with a minimum one and one-eighth (1-1/8") thick firebrick and the back wall firebrick were held off the units firebrick for the Floor, Backwall and Sidewalls. Thicker side walls. (Figure 29) firebrick may be used as an option. The pattern for the All required through-wall accesses (gas and air intake firebrick lining is an owner option.The ISOSET mortar by supply access holes) should be drilled before the required Earthcore is to be used when lining the Isokem Fireplace. firebrick lining is installed. Do not cover these areas with firebrick. The ISOSET Firebrick Mortar Application: Earthcore makes no claims as to the performance •Add .75 quarts of water per 101bs of dry product until of firebrick or firebrick mortar(s). It is typical for heat completely blended. stress cracks to appear in the firebrick in fireplaces. •Only mix what can be utilized within 15 minutes • Do not retemper(the addition of water after the chemical reaction has begun). •The use of warm water will accelerate setup I I •Joint thickness should be thin (1/16"-1/8") I I I •Complete set time is between 48&72 hours. • For best results, please allow seven days before heat is applied. •Approximately 35 to 40 lbs of prepared mortar will Expansion FIGURE 27 lay up one hundred 9x41 x21 " Straights. _ 1/2"Gap • DO NOT add additives such as fireclay,sand, cement, or other accelerators. These instructions may vary because of different climates and conditions. The use of good masonry practices for your area should also be considered. Installation Instructions: 1.Wet mop the inside of the fireplace with a damp sponge to remove dust and loose particles from the interior before firebricking. r- —\ I I I I I For Best Results: Expansion 1/2"Gap 1. After wet sponged interior of firebox apply a 1/4 notch bed joint on rear sides and floor. Fire Brick Floor 2. Dip each firebrick in a pale of water before applying r (Built First) mortar to one side for adherence to firebox. FIGURE 28 2. Face joint dimensions of 1/8" to 3/8" in the brick work is recommended and has the best appearance. Other face joint dimensions are acceptable however smaller joints may not leave room for heat expansion of firebrick. 3. Start the firebrick at the front edge of the floor of the lsokern firebox, proceeding inward toward the back. Let the floor brick gap approximately 1/2" off the back wall and side walls.This air space allows heat expansion of the firebrick and is to be left empty of mortar. (Figure 27) , l 4. Next, apply firebrick to the back wall of the unit.The back No Gaps ' wall firebrick covers the 1/2" expansion gap left at the brick Fire Brick Floor floor along the back wall of the firebox. (Figure 28) and Back Wall J (Built First) ' RECEIVED 5. Set the side wall firebrick by starting at the front edge ,� of the unit's side wall and working inward toward the back wall firebrick. The side wall firebrick, when completed, (FII gin 2 0 23 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 Flush Wall Finish Detail BVETTO units are designed to be installed so that the Clearance to Drywall: rough front face of the Isokern firebox and smoke dome sit Drywall can be placed directly in contact with the front flush to the room face of the rough framing members that of the BVETTO smoke dome. (Figure 24)With the Isokern create the room wall finish. firebox/smoke dome set flush with the interior face of wall framing, drywall can be hung on the framing members and IMPORTANT Do not build a combustible frame wall in pass across the face of the BVETTO smoke dome and in front of the BVETTO firebox/smoke dome assembly. contact with it. (Figure 30) The drywall must be cut back a minimum of eight inches (8") from the sides of the firebox opening and Wall Framing for the room wall where the BVETTO is eight inches (8") back from the top of the BVETTO firebox set must not be placed across the front face of the BVETTO opening, leaving BVETTO material exposed around the firebox and smoke dome assembly. face of the BVETTO firebox opening. These drywall cut back areas will be filled with grout in conjunction with the installation of the required fire brick lining requirements. Combustible wood sheathing such as plywood and particle board may be used to cover the front of the Isokern smoke dome and be in direct contact with it. Application of such combustible sheathings must assure that the sheathing is held a minimum of eight inches (8") away from each side of the finished fireplace opening and / a minimum of eight inches(8") inches above the top of the finished fireplace opening. (Figure 30&31) V If combustible wood sheathing is installed across the 11 1 ' face of the Isokem smoke dome front be sure that when ' , the required noncombustible finished facing materials \I (. 1' are applied directly to the front of the BVETTO, that no (/ gaps or voids are left behind the finished facing materials. I40 Completely seal the required noncombustible finished I facing materials directly to the Isokern unit with Earthcore 7 Adhesive or other non-combustible grout. ,III 1. IMPORTANT: Since there is no fire brick set along the FIGURE 30 • `II top of the BVETTO firebox opening, when setting the ,♦III noncombustible facing material onto the drywall across \tI I the top of the firebox opening there will be a gap between III the back of the noncombustible finish material and the rough front face of the Isokem Smoke Dome. (Figure 32) Be sure to fill this gap with Earthcore Adhesive in conjunction with placement of the code required noncombustible finish facingmaterial that is set across ,, the top of the firebox opening. WARNING: Avoid false I chimneys. I ,�1`�` Y !lir �1 ��1IMPORTANT: Failure to seal an a s between the front � 1 Ygp1` face of the BVETTO and the back of the noncombustible ' 11 �� I finished facing material will create what is known as 1L \' 1 ��i,`II �� a "false chimney" or "secondary chimney:' A "false � / chimney';in this case is the narrow gap (mentioned above) • /� between the back of the noncombustible facing material �ii, at the top of the firebox opening and the rough front of �� \� the BVETTO smoke dome. If left unfilled this gapereates a `` N�I I III "false chimney" which can cause a fire hazard by drawing b410j ► considerable heat out of the firebox and ``������ behind the noncombustible finish facing arR i ED ��� into the wall cavity behind the drywall or other sheathing FIGURE 31 material that houses the Isokern fireplace. 10/2 9/2020 24 ASPEN BUILDING DEPARTMENT Earthcore Industries 1112018 BVETTO B-Vent Gas Fireplace Clearance to Combustible Trim Mantle and Mantle Shelf Clearances: All combustible trim projecting less than one and one-half inch (1 1/2") must be kept eight inches (8") from the sides of the fireplace opening. All combustible trim projecting more than one and one-half inch (1 1/2") must kept twelve inches (12") from the fireplace opening. a2 be P P g minimum clearance (Figure 34) from opening Parts of the combustible mantle assembly located to ceiling along the sides of the fireplace opening, which project more than one and one half inches(1-1/2")from the face of the fireplace, shall have additional clearance equal to that of the projection. Parts of the combustible mantle assembly located above and projecting more than one and one half inches (1-1/2") from the fireplace opening shall not be placed less than twelve inches (12")from the top of the fireplace opening. (Figure 33) Adjoining Walls: Side walls and walls to rooms adjoining the Isokern fireplace installation cannot be closer than twenty four inches (24") to the finished fireplace opening. (Figure 33 Ceilings: The minimum clearance from the top of the fireplace Combustible FIGURE 32 Floor System opening to a ceiling is forty-two inches (42"). (Figure 32) (non-flammable) NOTE: "Clearance to Combustible Trim" are those distances required to ensure that a fireplace mantle or Adjoining Room Wall facing will not catch fire. In most cases the distances should also be adequate to prevent any discoloration or warping due to heat. However each installation presents a unique and completely different set of circumstances involving many variables. Fr/ S. These include paint or finish composition, previous _ ` exposure to heat, methods and quality of construction, air flow patterns, etc. Because of these variables, the B Hearth 12" manufacturer does not guarantee that heat warping or Extension 20" discoloration will never occur. (non-combustible) 24 1111 FIGURE 33 =M=I■ Hearth Extension (non-combustible) I/ Combustible IVED Floor System (non-flammable) 9t _R 4D20 25 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 ISOKERN Gas Log Set - General Information The BVETTO burner system is to be installed only in DO NOT USE IF GAS PRESSURE IS LOWERTHANTHE an ISOKERN B-vent (BVETTO) fireplace with a working MINIMUM REQUIREMENT. flue and constructed of noncombustible material. The The minimum inlet gas-supply pressure for purposes installation, including provisions for combustion and of input adjustment is 5" water column (w.c.) on natural ventilation air must conform with all guidelines found in gas and 11" w.c. on L.P. gas. Insuffi cient gas pressure the instructions supplied with the BVETTO fireplace. will affect proper operation of the pilot (if equipped). Do The chimney damper MUST be fully opened when not install this gas appliance if minimum pressure is not burning the unit.The unit is designed to burn with yellow available.The maximum inlet gas-supply pressure is 10.5" flames;thus adequate ventilation is absolutely necessary. w.c. on natural gas and To comply with certification, listings, and building 13"w.c.on L.P.gas.The L.P.source must be regulated. code acceptances, and for safe operation and proper (Do not connect this appliance directly to an unregulated performance of this burner system, use ONLY BVETTO L.P. gas tank - this can cause an explosion.) Do not parts and accessories. Use of other controls, parts, and connect this appliance to a portable L.P. gas cylinder. accessories that are not designed for use with BVETTO The gas piping system must be sized to provide burner systems is prohibited and will void all warranties, minimum inlet pressure at the maximum fl ow rate (BTU/ certifi cations, listings, and building code approvals, and hr). may cause property damage, personal injury, or loss of Undue pressure loss will occur if the pipe is too life. Earthcore will not be liable for any damages caused small, or the run is too long. Gas supply pipe must be by this misuse. 1/2" minimum interior diameter. If the gas line is longer than 20', a larger diameter line may be necessary. Refer IMPORTANT:Solid-fuels shall not be burned in a fireplace to the NFPA 54 guidelines for further details. where a decorative appliance is installed. Input ratings shown in BTU per hour are for elevations up to 2,000 ft. For elevations above 2,000 ft., refer to the BE CAREFUL: If not installed, serviced, and used National Fuel Gas Code or contact manufacturer before correctly per these instructions, this product can cause installing this product. serious personal injury, property damage, or loss of life. This gas appliance and its main gas valve must be This appliance is only for use with the type of gas disconnected from the gas-supply piping system during indicated on the rating plate.This appliance is NOT FIELD any pressure testing of that system at test pressures in CONVERTIBLE for use with other gasses. excess of 1/2 psig. CHECK GAS TYPE (natural or L.R): The gas supply This gas appliance must be isolated from the gas- must be the same as stated on your burner system supply piping system by closing the equipment shutoff rating plate. If gas supply is different, DO NOT INSTALL. valve connected to the gas-supply line during any Contact your dealer for immediate assistance. pressure testing of the gas-supply piping system at test INSUFFICIENT GAS PRESSURE WILL KEEP THE pressures equal to or less than 1/2 psig. PILOT (IF EQUIPPED) FROM OPERATING PROPERLY. Table 1 - Product Specifications BTU Rating Thermal Firebox Model Efficiency Burner Model - - • (purchased separately) Nat Gas LP Gas P4* High Low High Low ISO-IBV36 model IBV-36 65k 21 k 50k 22k 42% ISO-IBV46 model IBV-46 75k 22k 60k 23k 46% *P4(EnerGuidel is a measurement of the Canadian Office of Energy Efficiency. Efficiencies are based on Normal input operation. Table 2 -Technical Data Specification Value QTY. Burner system battery type AA battery 4 Remote transmitter battery type 12V battery 1 RECEIVED 10/29/2020 26 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVEI IO B VentGasFireplace ISOKERN Gas Log Set - Burner Parts List Thermocou•le . co �LL-, 13F __ 'C O Pilot '''1441( - s' Electrode I•. _ 1110 A \ , III I- 1 14 ,44 1 Y. , Luic., 15 I / O I -Flashtube O Remote transmitter and switch box batteries included with burner system. / 0 . _ 24/30 burner model shown - Note: Photos not to scale ►' , Replacement parts can be ordered 1 Irik -- . • ,,� re from your local ISOKERN dealer. CO ` The log set is purchased and packaged + separately;contactyour local ISOKERN4111 dealer when ordering. Refer to the O Q instructions included with the log set. Bottom view - L ISO-IBV36 model ISO-IBV46 model Item Description Part No. Qty. Part No. Qty. 1. Pilot assembly(natural) PAC-12 1 PAC-12 1 or Pilot assembly(propane) PAC-12P 1 PAC-12P 1 2. Control valve (natural) SV-47 1 SV-47 1 or Control valve (propane) SV-47P 1 SV-47P 1 3. Control module/remote receiver IMP-6 1 IMP-6 1 4. Main &motor harness assembly I WH-02 1 WH-02 1 5. Battery box BAT-02 1 BAT-02 1 6 Switch box assembly SBA-02 1 SBA-02 1 (includes battery box, switch,heat shield) 7. Decorative heat shield HS-42 1 HS-42 1 8. Flex connector(w/adapter), 1/2"O.D.x 24" CK-5-24SP 1 CK-5-24SP 1 9. Remote transmitter(only) AT-2VA-1 1 AT-2VA-1 1 10. Lava fyre coals LFC-6 1 LFC-6 1 11. Lava granules LF-5 1 LF-5 i 1 12. Glowing embers EM-21B 2 EM-21B 3 13. Brytecoals EM-11 1 EM-11 1 IE`'' "I�� 14. Wood chunks WC-6 1 WC-6 1 15. Log locator w/screw and nut(ISO-IBV46 model only) - - UP-17 2 10/2 9/2020 27 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 ISOKERN Gas Log Set - Wiring Diagrams cab' m iJ Pilot rim assembly insulated copper Black copper Main wire harness Gr n 1 White • (Main gas out) Orange Black 1 (GND) I1l OFT Pilot (Pilot gas out) EMaln GInlea -3 t Step motor j Valve —', Ignition main flame module d I Battery ( I. Red _ Main flame pack d I Black I S step output . II Motor wire harness FIGURE 351 WIRING DIAGRAM WIRING DIAGRAM TO SPILL TO SPILL SWITCH SWITCH AND POWER VENT Ignition Ignition Motor wire ..._` module Motor wire module harness harness To To Red ' fireplace Red r � fireplace 1� spill ,.3 spill Q 7r�. L switch - 'ice, i-- i switch Black Female Male Black a� Male ' l Red Female Black 1-11 Red Black Male Female Power vent Battery f control box pack Female Male Male Female Battery_' pack FIGURE 36 FIGURE 37 RECEIVEUJ 10/29/2020 28 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace ISOKERN Gas Log Set - Burner Installation The BVETTO burner system must be installed in an `. t ISOKERN B-vent (BVETTO) fireplace and by a qualified professional service technician. Instructions must be followed carefully to ensure proper performance and full _ NM benefit from the burner system. Check to be sure the `' I FIGURE 38 burner system is designed and labeled for the type of s—_ • gas (natural or propane gas) supplied to the fireplace. - Fireplace floor must be level, clean, and smooth. — — ---- Place burner WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts Keep clean and DO NOT specifically approved with this appliance may result ,, cover with embers N in property damage or personal injury. __ REFER TO THE PARTS LIST WHEN FOLLOWING FIGURE 39 THESE INSTRUCTIONS. - — ISO-IBV36 burner model shown here. Ensure a clean panel 1. MAKE SURE THE FIREPLACE GAS SUPPLY IS _ TURNED OFF. • 2. Place the burner system in the fireplace. Center the ' 0 Switch box burner from left to right in the fireplace. Reference Figure 35 for orientation. •l 1 't--:Alf `� FIGURE 40 NOTE: Ensure the porcelainized panel is clean of all dust. ��� 11 ."-4/. ' Use a clean soft cloth if necessary. (Figure 39) Aiiiii„,.. A 3. Disconnect the black wires, from the main harness to Aille the switch box, as shown in Figure 40. isc black wires For units to be installed without a power vent, Switch 1n harness wire follow step 4 below. For units to be installed with afilirDLownirneeirct_ •�F power vent follow step 5. I *si 1 4. Units without Power vent: Locate the two spill switch '. - i FIGURE 41 wires coming out of the hole in the lower right side of the trio _ .10 fireplace. Connect them to the free wires now coming from the main harness and switch box(male to female). , • See Figure 41 and the WIRING DIAGRAM TO SPILL SWITCH in the SPECIFICATIONS section. Connect spill switch wires RECEIVED 10/29/2020 29 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 ISOKERN Gas Log Set - Burner Installation I - 5. Units with Power vent: Locate the two spill switch Main harness wire Spill switch wire and two power vent wires coming out of the hole in the lower right side of the fireplace. Connect them to FIGURE 42 the free wires now coming from the main harness and switch box (male to female). See Figure 42, Figure 3, and the WIRING DIAGRAM TO SPILL SWITCH AND POWER VENT in the SPECIFICATIONS section. Power vent wire Spill switch wire Connect spill switch and power vent wires 6. At this stage the burner system batteries are to be installed. Reference the INSTALLING/REPLACING BATTERIES section for details. • ` 7. Place the switch box on its side, at the rear left corner •__ of the fireplace. It should rest with its bottom as near as FIGURE 43 , possible and facing the fireplace wall. It must not be Power vent wire Switch box wire placed directly next to the burner pan area to avoid damage to the batteries. See Figure 44& Figure 45. _ - IMPORTANT: Ensure that the box wire remains away Connect power vent to switch box wire from the burner system and its flame during operation. •• 8. Place the decorative heat shield over the switch box as Nir shown in Figure 46. FIGURE 44 ` ` 1'4 Place switch box Place switch box /4117 FIGURE 45 DO NOT place box , in this area Place switch box: • Rear left corner,on side, • exposed side against fireplace wa I Proper box placement Must rest on floor and at rear corner FIGURE 46 `~J RECEIVED CEIVED Place heat shield 10/29/2020 30 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace ISOKERN Gas Log Set - Burner Installation 9. Locate the gas-supply stub inside the fireplace and Gas su..l stub remove the cap, if attached. CAUTION:When removing the cap, make sure the stub • does not turn, loosening the connection inside the wall. FIGURE 47 10. Be sure gas to the fireplace is off. Remove the Flex connector Adapter adapter connected to the flex connector(pre-installed on the burner system).Attach the adapter to the gas-supply stub using a pipe compound resistant to all gasses. Tighten securely. Then attach the open end of the flex Connect gas supply connector to the adapter.Tighten securely. (Figure 47) 11. LEAK TEST Turn on the fireplace gas supply, and test � \� at all connections for leaks using the appropriate soapy water solution. If bubbles appear, a leak is present.Turn FIGURE 48 off the gas and tighten at all connections. Repeat until • no leaks are present. If a leak persists, turn off the gas supply and contact the local gas company or dealer. NEVER USEA FLAMETO CHECK FOR LEAKS. Place lava media 12. LIGHTING TEST: Prior to proceeding with installation, perform a lighting test (see lighting instructions for lighting your burner). Allow the unit to completely cool after testing. 13. Spread the supplied lava granules on the floor of the fireplace, around the front and sides of the burner system. (Figure 48) The lava granules may be placed around the switch box. Leave the front of the switch box clear for control access. 14. Repeat this process for the supplied lava coals (on top of the already placed lava granules). NOTE: DO NOT place any lava media on the burner system, or behind it. 15. Spread the supplied wood chunks on the lava media, around the front and sides of the burner system. Leave the front of the switch box clear for control access. NOTE: DO NOT place any wood chunks on the burner system, or behind it. LOG LOCATORS (if applicable) IMPORTANT: For all valves,the air MUST be purged from ISO IBV 46" models include a set of log locators. They the gas line before the pilot will light and burn properly. are used to support the front logs of select log sets. If The time needed to purge will depend on the length of the log set chosen includes log locator install details (in the gas line to the unit and the amount of time since the placement instructions), install accordingly. If not, discard unit or gas line was last used. It may take several minutes the log supports. before all the air is purged and the pil d burn properly. Reference the LIGHTING�,; section in this manual. 10/29/2020 31 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 ISOKERN Gas Log Set - Log Set Installation Log Set Placement Follow the instructions included with the log set for . step by step log placement. Read all safety warnings and l~wras,.», important information in the instructions supplied with te�, f5i :: rtf -a the log set to ensure proper placement. t '" ;' IMPORTANT DO NOT add any additional embers to this log set.Any additional embers will cause unsafe operation. )," IMPORTANT: Adequate ventilation is absolutely necessary! Provided significant, noticeable sooting does -% • t= " not occur, some flexibility is possible in log placement Charred Hickory(ISF CH 24) shown to suit your individual preference (select log sets). If you experience a continued accumulation of black carbon (soot) on your logs it is an indication of incomplete combustion and you should move the effected log(sl so as to minimize the flame contact on the effected log(s). Read the instructions supplied with the log set completely and carefully. '1444,14 �� _ CAUTION: BURN HAZARD! Logs will remain hot for ' 0 , + 4. -4, some time after use. If you need to reposition any log to maintain the proper layout, use heat-resistant gloves or t, allow logs adequate time to cool before handling. Summit Pine (ISF-SP-24) shown a = _ < -t" bt t i'eta s p� 'YC k i1 )" ''''r� w✓� Sandhi!! Oak (ISF-SH-24) shown RECEIVED 10/29/2020 32 ASPEN BUILDING DEPARTMENT Earthcore Industries 112018 BVETTO B-Vent Gas Fireplace ISOKERN Gas Log Set - Installing/Replacing Batteries CAUTION: Ensure the unit is connected to the gas line and has been tested for leaks before you insert batteries. iffr CAUTION:Turn off the remote and/or burner and allowthe unitto completely cool prior to any battery replacements. Important: Prior to inserting batteries, always apply a smallamount of dielectric grease to both ends of each battery. This will ensure conductivity and prevent moisture from affecting the contact. Remove lid for FIGURE 49 IMPORTANT: Low/dead batteries will affect burner 12V battery system operation. Replace batteries any time the burner access 1114 will not turn on. RemoteTransmitter Battery The remote transmitter requires one 12V battery to operate (included).Locate the transmitter, remove the lid (found on rear), and properly insert the new battery as marked. Re-secure the lid. (Figure 49) Switch Box Batteries The burner system requires 4 AA batteries to operate (included). Locate the switch box and turn it over. Detach the battery box from the Velcro. Use a small Phillips screwdriver to remove the screw found on the bottom of the battery box, then remove the battery lid. Properly insert the new batteries as marked. (Figure 50) Replace AA Batteries the battery lid using the screw, replace the battery box ontothe Velcro, and re-position the switch box in the ` �� �� fireplace. IMPORTANT: Always replace the decorative heat shield over the switch box after battery replacement. i FIGURE 50 RECEIVED 10/29/2020 33 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 ISOKERN Gas Log Set - Lighting Instructions FORYOUR SAFETY,READ BEFORE LIGHTING C. Use only the control system or remote to light the pilot.This valve will not operate if the pilot is not lit and WARNING: If you do not follow these instructions stable. exactly, a fire or explosion may result causing property damage, personal injury or loss of life. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician A.This appliance is equipped with an ignition device that to inspect the appliance and to replace any part of the automatically lights the pilot. DO NOT attempt to light control system and any gas control which has been the pilot by hand. under water. Attempted operation may result in fire or explosion resulting in property damage, personal injury B. BEFORE OPERATING, smell all around the appliance or loss of life. area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. Remote Lighting CAUTION: DO NOT attempt to light the pilot by hand. WHATTO DO IF YOU SMELL GAS: • Do not light any appliance. NOTE: If the remote does not function, and batteries • Do not touch any electric switch; do not use any with an adequate power level are installed, refer to the phone in your building. SYNCING THE REMOTE section. •Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. NOTE: Steps 1 and 2 may not be required if previously If you cannot reach your gas supplier, call the done during an earlier lighting. fire department. 1. Locate the ON/OFF switch at the front of the switch box. Press the switch to the OFF (0) position. (Figure 51) ON FIGURE 51 Qom' '1/ 2. Locate the OFF/REMOTE slide actuator on the left rear OFF of the burner. Slide the actuator to the right / REMOTE position. (Figure 52) \ J Switch box,ON/OFF 3. Locate the remote transmitter and press the ON button. (Figure 53)The system will beep and the ignition Remote receiver 0 sequence will begin. The igniter will begin to spark. After the pilot lights andis established, the valve will automatically open and FIGURE 52 the burner will light. Adjust to the desired setting with ®(� � the remote transmitter. See the REMOTE OPERATING INSTRUCTIONS section for details. NOTE: The ignition sequence will take approximately 5 OFF/REMOTE slide actuator (left rear of burner) seconds. WARNING: If pilot fails to light within 10 seconds, press the OFF button on the remote transmitter or slide the Signal OFF/REMOTE slide actuator (left) to OFF to turn off the light 0 ON system. Allow five (5) minutes for any gas in the unit to button dissipate, then repeat steps 2 &3 above. IFYOU SMELL ON ) GAS,SEE STEP B ABOVE. FIGURE 53 OFF OFF ) If the pilot fails to light after several tries, turn all button ( HI )• HI-LOW control/remote system components to OFF and contact flame a qualified professional service technician. ( Low) adjustment buttons RECEIVED Remote transmitter detail 10/29/2020 34 ASPEN BUILDING DEPARTMENT Earthcore Industries = BVETTO B-Vent Gas Fireplace ISOKERN Gas Log Set - Lighting Instructions Manual Lighting CAUTION: DO NOT attempt to light the pilot by hand. Remote receiver c� 1. Locate the OFF/REMOTE slide actuator on the left rear of the burner. Slide the actuator to the left/OFF position. I FIGURE 54 (Figure 54) 2. Locate the ON/OFF switch at the front of the switch box. Press the switch to the ON (I) position. (Figure 55) The igniter will begin to spark. After the pilot lights and OFF/REMOTE slide actuator(left rear of burner) is established, the valve will automatically open and the burner will light. NOTE:The ignition sequence will take approximately 5 seconds. ON WARNING: If the pilot fails to light within 10 seconds, OFF FIGURE 55 turn OFF the system. Allow five (5) minutes for any gas in the unit to dissipate,then repeat step 2 above. IF YOU SMELL GAS, SEE STEP B AT BEGINNING OF Switch box,ON/OFF LIGHTING INSTRUCTIONS. If the pilot fails to light after several tries, turn the 1 system OFF and contact a qualifi ed professional service technician. NOTE: In manual mode, the remote transmitter will not operate the burner system. FIGURE 56 Shutting Down • For remote shut down, press the OFF button on the remote transmitter. If remote is unavailable, slide the OFF/REMOTE slide actuator(on left rear of burner)to the left/OFF position. Proper pilot flame • For manual shutdown, press the ON/OFF switch on the front of the switch box to the OFF (0) position. NOTE: If the system needs to be relit immediately after shutting down,the thermocouple will require 20 seconds to cool down before the system can reignite. Pilot Appearance Periodically check the pilot for proper flame pattern. The pilot flame should encircle the, and is preset at the factory. (Figure 56) If the pilot flame burns incorrectly; shut down completely and contact a qualified professional service technician. RECEIVED 10/29/2020 35 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 ISOKERN Gas Log Set - Remote Operations ORIENTATION Prior to remote transmitter use, light the appliance per the REMOTE LIGHTING section. The remote transmitter will only operate the unit when it is in the Signal 1 remote mode. Familiarize yourself with the transmitter light 0 ON buttons, as illustrated in Figure 57. 'button Identify the four transmitter buttons (used with this system): ( ON )•' • ON BUTTON:Turns the system ON. • OFF BUTTON:Tums the system OFF OFF /i'( OFF ) • HI BUTTON:When the system is on, this button is button ( HI )• HI-LOW used to increase the flame to the desired height. flame • LOW BUTTON:When the system is on, this button ( Low) adjustment is used to decrease the flame to the desired buttons height. FLAME HEIGHT Remote transmitter detail Seven flame height levels are available. Press the HI or LOW buttons to enter the Flame Height mode. Pressing the HI or LOW button once will increase or I FIGURE 57 decrease the flame height by 1 of 7 increments. (Figure 54) RECEIVED 10/29/2020 36 ASPEN BUILDING DEPARTMENT Earthcore Industries >>l2ni 8 BVETTO B-Vent Gas Fireplace ISOKERN Gas Log Set - Cleaning & Servicing NOTE:Servicing may be necessary to ensure proper pilot Flame Description operation and proper burn characteristics.Always shut off Observe the flames. The top and middle burner the gas to the appliance while performing service work. flames should be blue at the base and a combination of blue/yellow at the body and at the tips.The top flames Allow the appliance to cool before servicing. should be approximately 3-5' above the logs, with the center flame being the tallest.The middle flames should Installation, service, and repair must be done by be approximately at or below the top of the front log.The an NFI Certified or other qualifi ed professional service ember flames should be 1/4" to 1" above the embers. technician. The appliance should be examined before (Figure 59) use, and must be inspected at least annually to prevent burner shutdown,sooting,odors,etc. It must be checked for clean burning operation and proper pilot appearance, with the correct tools to service this unit. More frequent servicing may be required. It is imperative that all control components and compartments, burner(s), air shutters, and circulating air passageways of the appliance be kept . (rear of burner assy) '` J clean and free of all obstructions (as applicable). . In addition,a periodic examination and cleaning of the — — Control module ISOKERN fireplace venting system should be conducted -- by a qualified professional service technician. - Any safety screen or guard removed for servicing --�q must be replaced prior to operating this appliance. �_ -14 Verify proper operation after servicing. • If, after a period of use, the flames start to exhibit SYNC button unusual shapes and behavior, or the burners fail to ignite smoothly, the burner may require cleaning or servicing. If Sync detail FIGURE 58 this happens, it is recommended to contact the nearest dealer to get the appliance serviced. Do not remove the rating plates or the warning tags.These are an integral safety and identification r -- component of this appliance. We recommend following these instructions at the beginning of each fireplace season and as needed -�«. throughout the year, depending on your usage pattern ''� and the environmental conditions in your home. More 1, ' , frequent cleaning and maintenance may be necessary . when burning propane gas than with natural gas. �. I►+ IF Syncing The Remote System ' _ NOTE: Syncing the remote system will cause the burner ,4.,,, �-.,y. ! �, to ignite. r. ‘)........---.rtiri:•«.S IIF,•-% , Ensure the burner system is off and completely cool. " : y<Y_ The remote receiver (found on the rear of the burner Flame appearance assembly) has a sync button. (Figure 58) Locate the OFF/REMOTE switch actuator on the left FIGURE 59 rear of the burner.Slide the actuator to the right/REMOTE position, then press the sync button and release. One beep will be heard.Then press and hold the ON button on the remote transmitter, until 4 rapid beeps are heard and the pilot begins to spark.The remote system is now synced. If ignition is not desired, press OFF on the remote to shut off. RECEIVED 10/29/2020 37 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 11/2018 ISOKERN Gas Log Set - Troubleshooting BURNER SHUTTING DOWN DURING OPERATION A. Insufficient or excessive gas pressure Al.Check gas pressure(Read D.-F.of IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION section,&checkwith local gas company). A2. Other gas appliances may be on the same gas line, dropping gas pressure to log set.Check pressures with everything operating to ensure adequate pressure. B. Log placement B. Reference the LOG PLACEMENT section in this manual for recommended log positioning. C. Pilot flame lifting off thermocouple/generator C. Check gas pressure (see section Al). D. Pilot (remote compatible) D. Contact your dealer for instructions on replacement. E. Blockages on burner E. Vacuum any lava granules or material that may have fallen onto burner pipe area. PILOT WILL NOT LIGHT A. Pilot flame lifting off thermocouple/generator A. Check gas pressure (see Section 1, Al of this table). B. Electronic spark not lighting pilot B. Check to ensure sparking when activated. Note:You may need to turn or press igniter several times to ignite pilot. See LIGHTING INSTRUCTIONS for your control valve. C. Igniter electrode wire loose C. Check wiring and reconnect any loose wiring. D. Gas supply off/manual shutoff valve closed D.Turn on gas supply or open manual shutoff valve. E. Air in gas line E. Bleed the gas supply line and repeat LIGHTING INSTRUCTIONS until air is removed. F. Pilot hood blocked F. Check for debris or dirt/Clean pilot LOW FLAME HEIGHT A. Gas pressure A. Check gas pressure (see Section 1, Al of this table). BURNER NOT BURNING EVENLY A. Burner orifice clogged A. Clean burner orifice. B. Remote set on low fl ame (if option available) B. Adjust flame with remote transmitter. C.Top burner lights; Cl. Check gas pressure. Can be caused by too small of a gas line (see bottomburner has delayed ignition. Section 1, Al of this table). C2. Low propane ODORS A. Gas leak A. Shut off gas, if possible. Follow instructions on front page. Have a qualified professional installer or the gas company correct all leaks. B. New home, new carpet, or new paint B. When these odors are drawn into the fireplace, this may cause objectionable odors. Thoroughly ventilate the area before restarting your log set. C. Damper closed C. Ensure that damper is open. PILOT WILL NOT STAY LIT A.Valve won't hold A. Contact your dealer for instructions on replacement. B. Pilot hood not aimed at thermocouple B. Pilot hood bent; replace pilot or angle pilot hood properly so pilot flame hits thermocouple. C. Pilot line bent/kinked at connection to valve C. Replace pilot line. D.Thermocouple is loose D.Tighten thermocouple nut at gas control valve. (Do not over tighten.) E.Thermocouple cracked or worn out E. Replace thermocouple. E Excessive down draft F. Install chimney cap / Outside chimney too close to other peaks / Check chimney flue for proper height/Poorly designed chimney. BURNER WILL NOTTURN ON A. System deactivated due to closed damper A. Open damper. RECEIVED L�J� .� B. Low/dead batteries in remote transmitter B. Replace batteries as needed (if applicable). AND/OR remote receiver/switch box (select models only) 10/29/2020 38 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace General Information & Components The environmentally friendly ENERVEX EcoDamper Component Part# Description System is the first completely automated draft and damper system for use with gas fireplaces. The EcoDamper System quietly manages a perfect draft and prevents conditioned air from escaping through the chimney when the fireplace is not in use. It eliminates the need for glass doors, opening up many new design IXH0021 RS 9 Chimney Fan options while allowing for a larger view area of the fire and a more natural look. The system consists of the RS 9 Chimney Fan, the Mechanical Fireplace Damper (MFD), the ADC100 Control and the PDS-1 Proven Draft Switch. RS 9 Chimney Fan - Made of high quality, recycled cast aluminum, RS Chimney Fans keep the perfect draft for a long time.The EXH2810 24 MFD Mechanical Fireplace Damper fan features a quiet, enclosed pre-lubricated motor and is recommended to be used with gas or oil fireplaces, stoves, ovens, furnaces, water heaters, BBQs and pizza ovens. MFD Mechanical Fireplace Damper The low profile Mechanical Fireplace Damper (MFD) is an accessory to be used in conjunction with an ADC100 "°`10 0 ' control and a chimney fan as part of the EcoDamper and IXH0060 ADC100 Draft Control Intellidraft System.This damper prevents conditioned air (includes PDS-1) •NMYI% from escaping through the chimney when the fireplace is not in use and eliminates the need for glass doors. ADC100 Draft Control The ADC100 Control, for gas appliances, has pre- Mil • and postpurge features, an integrated damper relay and includes a draft switch that shuts the appliance off when EXH1130 PDS-1 Proven Draft Switch ..,. (included with ADC100) there isn't enough draft, protecting your family from • dangerous flue-gasses. PDS-1 PROVEN DRAFT SWITCH Use the PDS-1 Proven Draft Switch to provide protection from insufficient draft.When there is an unsafe draft, the switch shuts down the gas-fired appliance or fireplace. Installations must conform to requirements of the authority having jurisdiction. Where required by the authority having jurisdiction, the installation must also conform to the Standard for Draft Equipment and The National Fuel Gas Code, ANSI Z223.1/NFPA 54. All electrical wiring must be in accordance with the requirements of authority having jurisdiction or, in the absence of such requirements, with the National Electrical Code, NFPA70. This installation manual does not contain any system design documentation. System design documentation is available from any authorized ENERVEX representative. RECEIVED Accessories, fans, and variable frequency drives are ,! not covered by this manual. Please refer to these component's individual manuals. 10/29/2020 39 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 1/20}8 ECODAMPER System - Installation TO REDUCE THE RISK OF FIRE, ELECTRICAL MECHANICAL DRAFT SYSTEM FOR A GAS-FIRED SHOCK OR INJURY TO PERSONS, OBSERVE THE FIREPLACE WITH DAMPER AND SAFETY SYSTEM FOLLOWING: PER NFPA 54/IFGC 1. Use this unit in the manner intended by the manufacturer. If you have questions, contact the Application manufacturer at the address or telephone number listed This installation shows a combination fireplace on the front of the manual. and damper system. The ADC100 control monitors fan and damper operation and the safety system. No 2. Before servicing or cleaning the unit, switch off at adjustments are necessary after the system is installed service panel and lock service panel to prevent power and commissioned. The ADC100 does not have to be from being switched on accidentally. visible and can be installed in the attic. (Figure 60) 3. Installation work and electrical wiring must be done by Proven Draft Switch is part of ADC100 control. a qualified person(s) in accordance with applicable codes and standards. SEQUENCE OF OPERATION 1. During commissioning, the fan speed is set using the 4. Follow the appliance manufacturer's guidelines and potentiometer located on the ADC100 control board. safety standards such as those published by the National Fire Protection Association (NFPA), and the American 2. When the gas igniter is activated, the fan speed Society for Heating, Refrigeration and Air Conditioning increases and the damper begins to open. Once the Engineers (ASHRAE), and the local code authorities. damper is fully open and the proven draft switch closes, the fan returns to the speed setting of the potentiometer 5.This system must be grounded. and the ADC100 releases the gas valve. 3. If proper draft is not maintained, the ADC100 will increase fan speed gradually until the PDS closes. If the Chimney PDSo has not closed 10 seconds after the fan reaches Fan =__ "' 100% speed, the ADC100 will shut off the gas valve and go into alarm mode. If the PDS closes while in alarm mode, the fan will resume the original speed setting. ' Junction MFD Automated i Box 4. Once the fireplace is turned off, the fan will continue Damper " to operate for a set post-purge time (adjustable between 0-10 minutes) to remove any remaining products of Chimney combustion before shutting down.The damper closes 10 Probe • seconds after the fan is shut off. 5. In case of a mechanical or electrical failure the ADC100 PDS, Proven will shut off the gas valve. ADC100 Draft Switch 0 Gas I. Valve y I _ , o 0 RECEIVED FIGURE60 10/29/2020 40 ASPEN BUILDING DEPARTMENT Earthcore Industries 111201 s BVETTO B-Vent Gas Fireplace ECODAMPER System - Wiring Diagram FAN MOTOR C . a I I 1 I 0 e I i x 1 � ADC 100 1 � I I I 11241249126 AUX 2 ALM I I P01 /AUX 2 Au%I vM ID AC FAR OUT M RRELAY PROM RELA CTRL OUTT OUTn 1;100I0100 R ® 000 I011 M 010 0I0 ®I0�0I0I0® ® 000 I I i FIGURE 61 I I L rJ I I I I 1 LIN L LL� .J 1•1120 VAC r AP RAt L I ; L ENH Must Be DocketedJ PDS-1 FIREPLACE POORSuPPLT mow Lt L---- CAS VALVE 1•120 WC GENERATOR NOT CO' N I I I C ND NC TN TR a 0 0 0D 0 pER0 ACTUATOR OR IGNITION RECEIVED 10/29/2020 41 ASPEN BUILDING DEPARTMENT Eartheore Industries BVETTO B-Vent Gas Fireplace '1'2018 Notes R t,. ',iV D 10/29/2020 42 ASPEN BUILDING DEPARTMENT Earthcore Industries 11/2018 BVETTO B-Vent Gas Fireplace Registration Card Please tear out along dashed lines and send to: Earthcore Industries Attn:Technical Department 6899 Phillips Industrial Blvd Jacksonville, FL 32256 Dealer Date of Purchase: Date Of Installation: Address: City, State, Zip: Phone No.: Fireplace Size (Circle One): BVETTO 36" (80B36) BVETTO 46" (80B46) Gas Type (Circle One): Natural Gas Propane Fireplace Serial Number: (Located on Rating Plate Inside Fireplace) Buyer: Address: City, State, Zip: Phone No.: Installed By: Address: City, State, Zip: Phone No.: RECEIVED 10/29/2020 43 ASPEN BUILDING DEPARTMENT /�/ii• ♦� •i'i'.7•i i' `I .i�`c, ii' ♦� .i'i',. v `I -•ii,:���ii' ♦� •i'i�.;iS `I -1 �`i�:'is ♦t/ •i'i�0�-•;i•• `I 1 �`i�h';;; ♦t/ v ��I-•i' `I •i1 �.r ��r.44k� rsQ /I�e `r� r�� fir �r� u�� /I�.r `r� r�� �d �r� r.�� I�.r `r� N� �.r �r� e��!.I6Alyik:t.r `r� r�� I�,r �r� t���.I4Pitx•Fii.r `r� r���\ .� ;. ..\��� .Q.. � � cam •/flAf' �: , ,. � � ..� \ " ..� . � .. ==arrantp & Mizriaimer Isokem BVETTO B-Vent Gas Fireplace "'` : -.tt! Earthcore offers a Lifetime Warranty for all Isokern components, to be free from defects in materials that negatively )11 :` > % affect system performance from the date of purchase, subject to the terms and conditions of this limited warranty. '�\ e:I. This warranty covers only the above stated components.THIS WARRANTY DOES NOT COVER DRAFTING, SMOKING !0 i.:7 ` �• OR PUFFING OF THE FIREPLACE SYSTEM. Factors beyond the manufacturer's control affect fireplace drafting, %"•% j:�!! smoking, and puffing, and ISOKERN cannot guarantee these aspects of performance. A:E ' EXCLUSIONS AND LIMITATIONS ! i This Lifetime Warranty applies only if the Isokern Product is installed in the United States and Canada and only if Q�` operated and maintained in accordance with the printed instructions accompanying the Product and in compliance with j " ,•.;. all applicable installation and building codes and good trade practices.This warranty is non-transferable and extends to • it .. the original owner only.The following do not carry the Lifetime Warranty but are warranted as follows: �� ': Burner-The BVETTOgas logburner has a oneyear warrantyagainst anyperformance defects. - :;;zi �� 9 = =-� :• Gas Logs-The BVETTO gas logs have a one year warranty against breakage;except breakage due to mishandling or is negligence. lit!i Control Valve- If the BVETTO gas log burner was purchased with a gas control valve,the gas control valve has a ones year warranty against any performance defects. :` •r Gas Logs -All painted surfaces that get wet due to rain, flooding, household pets, wild animals or birds, or get s:e ed er, arranty. ` Accessories due-to negligence and lava coaltthat have get wet due to rain, flooding, householdpets, wild animals or birds, orget •/��_ %‹ damaged due to negligence or disaster, have no warranty. '� �.. r-4 Parts not otherwise listed carry a 90 day warranty from the date of installation. �� he terms of this warranty the ty o hom s warranty s �% shall component ofy Earthco a 6899 Phill ps defective dusty Industrial Blvd, Jacksonville, Florida 2256r ntw it writing, byl registered Imail twitthinn �S thirty(30)days following the discovery of the defect within the lifetime warranty period.The notice shall contain(1)the date of purchase; (2)place of purchase; (3)address of installation; (4)name, address and phone number of the owner, '�I` and (5)a brief description of the defect. ''e*. %% Earthcore, or any division thereof, is not responsible for any labor costs or indirect costs incurred for the replacement -� �� of defective components. •'!� ' � Earthcore is not responsible for misuse or mishandling of components. Nothing in this warranty makes Earthcore, or �� : j�!':- any division thereof, liable in any respect for any injury or damage to the building or structure in which the fireplace or '!�: . •=hl_/_ chimney system has been installed or to persons or property therein arising out of the use, misuse, or installation of �._ ::• properly manufactured ISOKERN product. ::° • EARTHCORE,ORANY DIVISI ONTHEREOF SHALL NOT BE HELD LIABLE FORANY INCIDENTAL OR CONSEQUENTIAL :-.. •<<': DAMAGES OR EXPENSES ARISING OUT OF THE USE OF THE FIREPLACES OR CHIMNEY SYSTEMS. ALL SUCH 'l1 DAMAGES AND EXPENSES ARE HEREBY EXCLUDED. This warranty is null and void when the fireplace or chimney systems are not installed pursuant to the installation :-•••• S ; instructions provided by Earthcore or local building codes have not been followed completely. ;j .- This warranty applies only to those fireplace and chimney systems installed in the continental United States and ,,:=• Canada. If any part of this warranty is found to be unenforceable, the remaining parts shall remain in force and effect id. ljc EARTHCORE HEREBY DISCLAIMS ALL GUARANTEES AND WARRANTIES, EXPRESS OR IMPLIED, BEYOND THE 'j i% WARRANTIES SET FORTH HEREIN. '`'� eart h core° `'' : ::::.. .��-40: 6899 Phillips Industrial Blvd. ••Jacksonville, FL 32256 ••904.363.3417 ••f: 904.363.3408 •• earthcoreREC E �,,s :„.........,....„ ,.;.......„ „... ....„.... ).: z,.:.t.,,,, :AC .-!:'41.... *;a:: d.t.:.,,f, 19-N:: .44':',-. >1..E....': d.t.:.,,,T, 21.=-:< ...,T.t.t, *;*:,,,!;•,1,,,•:::-*;:!..1,. .,0;;;:;(;) V�,;./r `0- :•Vt./ r``.r. 1)i./ r `„�.0• , r``,X %/ r 10"`r, t :.. r`r.427:"_%. r `r.••p. N, r``r.!. ...;.//r`4.! •..,r,//r`.,,�i ?AKE 004_09., BUILDING DEPARTMENT