HomeMy WebLinkAboutFile Documents.1315 Sage Ct.0082-2021-BRES (30) SCIENCE. SERVICE. SOLUTIONS. G4RLISLE COATINGS & WATERPROOFING ■ 9 : II Vapor-Lock Description installation.Terminate flashing on wall per Carlisle 500-9 Details.Install Carlisle's Vapor-Lock System utilizes the CCW-711-90 sheet membrane CCW-500 Membrane over horizontal portion of flashing and onto the as a preformed first course on difficult-to-waterproof substrates vertical portion during the field membrane installation. such as lightweight structural concrete and wood.The CCW-711-90 Install Sure-Seal®EPDM,Sure-Seal FleeceBACK®115-mil EPDM or sheet membrane is a 90-mil composite consisting of a self-adhering Sure-Seal FleeceBACK 120-mil AFX TPO flashings in exposed areas per rubberized asphalt membrane laminated to high-strength, heat resistant Carlisle recommendations.Apply a thin film of CCW Contact Adhesive woven polypropylene mesh.The woven mesh is designed to withstand in a four foot square area around drains.Allow primer to dry one hour high temperatures,allowing the membrane to become an integral minimum,eight hours maximum.Apply 90 mil of CCW-500 membrane to reinforcement part of the CCW-500R Hot-Applied Membrane System. cover primed areas.Install a three foot square section of CCW-711-90 or uncured neoprene flashing over the drain and onto the deck. No splices The second course of the Carlisle Vapor-Lock System is the application or seams are allowed within three inches of the drain flange.Terminate of CCW-500.The CCW-500 is a single-component rubberized asphalt the flashing under the clamping ring of the drain and cut away the inner compound that forms a tough,flexible, monolithic membrane over the portion of the flashing.Use firm pressure to press the flashing against the CCW-711 sheet membrane.The fast setup time speeds the completion of CCW-500 surface and ensure good adhesion. Do not interfere with weep the waterproofing system. holes. The Vapor-Lock System is used to waterproof lightweight structural Apply CCW Contact Adhesive to all surfaces to receive CCW-711-90 sheet decks, inverted roof systems with steel decks covered by gypsum, membrane.Avoid puddles.Allow primer to dry for one hour minimum, DensDeck®or plywood.The Vapor-Lock System is also ideal for eight hours maximum. Membrane will not properly adhere to wet primer. conventional waterproofing of split slabs,tunnels and plaza decks. Apply CCW-711-90 sheet membrane from low to high point,in a shingle fashion so that laps will shed water. Begin installation at low edge of Installation deck overlapping horizontal portion of previously installed flashings. Surface Preparation:The substrate surface must be thoroughly clean, Overlap all edges at least 2'h".End laps shall be staggered.Place dry and free from any surface contaminates or cleaning residue that may sheet membrane carefully so as to avoid wrinkles and fishmouths.After harmfully affect the adhesion of the membrane. installation, roll with a metal roller wrapped with a resilient material. Detailing and Flashing: Detail expansion joints per manufacturer's Roller should be 18" 24"wide and weigh at least 100 lbs. recommendation. Preferred Curb and Parapet Flashing Method(VL- Heat CCW-500 membrane blocks in a twin wall kettle with continuous 5004A):Apply CCW Contact Adhesive at the juncture of all horizontal agitation(Caution: Do not exceed maximum safe operating temperatures surfaces and vertical surfaces to the height indicated on the drawings of 375°F.) Apply a coat of CCW-500 Hot-Applied Membrane at a rate of (8" min. recommended),such as parapet walls,curbs,columns and all 13 sq.ft.per gallon or as required to obtain an average thickness of 125 penetrations through the deck.Avoid puddles.Allow primer to dry for one mils.Total thickness of the CCW Vapor-Lock System shall be 215 mils. hour minimum,eight hours maximum. Membrane will not properly adhere Apply CCW-500 at 125 mils over the CCW-711-90 flashing or uncured to wet primer.Apply 90 mils of CCW-500 membrane to cover primed neoprene flashing. areas. Install CCW-711-90 sheet membrane or uncured neoprene flashing into this first course of CCW-500 to cover the vertical section and extend Protection Course:The membrane must be protected from damage. 6"onto deck surface. Flashing installation may be done during crack Install CCW Protection Board H or HS while CCW-500 is still warm and and joint.Completely cover all flashing material during installation of the tacky. CCW Protection Board shall be spliced together using CCW-500 subsequent layers of CCW-500 membrane. for expanded warranties.Integrity testing can be performed with the At the juncture of all horizontal surfaces to vertical surfaces,such as protection board installed. Install CCW MiraDRAIN and CCW Root Barrier parapet walls,curbs,columns and all penetrations through the deck, relative to the requirements of the designed overburden. apply CCW Contact Adhesive on the vertical sections to the height Testing: Test is required for all expanded warranties beyond the indicated on the drawings 8" min.recommended).Allow primer to dry. standard material warranty of horizontal applications.The test can Apply the CCW-500 over the primed substrate.Install CCW-711-90-mil be done with Electronic Vector Mapping or flood testing.Flood testing or over the CCW-500 to cover the vertical section and extend 6"onto requires 2" minimum head of water for a period of 24 hours. the deck surface.Install CCW-500 Membrane over horizontal portion of flashing and onto the vertical portion during the field membrane Carlisle Coatings&Waterproofing 900 Hensley Lane I Wylie,TX 75098 1800.527.7092 I www.carlisleccw.com SCIENCE. SERVICE. SOLUTIONS. G4RLISLE COAT/N... & WATERPROOFING 1 A11 m ■ 11 ■ „ 1 , Vapor-Lock Flood Test:Allow CCW-500 membrane to cool. Plug drains and provide Typical Properties barriers necessary to contain flood water. Flood surface with two inch head of water for 24 hours.Inspect for leaks and repair membrane if Property Method Typical Value leaks are found.Retest after making repairs. Solids Content ASTM D1353 100% Repairs:In the event the CCW-500 Hot-Applied Liquid Membrane is Flow ASTM D5329 Control<3 damaged,clean the area with a cloth wet with mineral spirits,allow Post Heating<3 to fully dry and apply CCW-500 Hot-Applied Liquid Membrane to the Penetration(1/10 mm) ASTM D5329 Control @ 77°F=76 damaged are Control @ 122°F=124 Post Heating @ 77°F=72 Coverage Rate Post Heating @ 122°F=108 g Flash Point ASTM D92 579°F(304°C) The following is a guide to estimate the amount of materials required for Water Vapor Permeance ASTM E96(E) 1.2 ng/Pa•s•m2 various membrane thicknesses. Elongation ASTM D412 >1,000% 215 mils applied=1.53 Ibs/ft2=7.46 ft2/gal Toughness CGSB-37.50-M89 8.5J 125 mils applied= .89 Ibs/ft2=12.83 ft2/gal Ratio of toughness to peak load CGSB-37.50-M89 0.044 90 mils applied=0.64 Ibs/ft2=17.83 ft2/gal Adhesion CGSB-37.50-M89 Pass Viscosity CGSB-37.50-M89 Control-6 Limitations Post Heating-4 • Do not apply CCW-711-90 membrane if temperature is less than 25°F. Water Absorption CGSB-37.50-M89 0.32g Do not apply CCW-500 membrane if temperature is less than 0°F.Do max.0.35g[gain] not install waterproofing to a damp,frosty or contaminated surface. Pinholing CGSB-37.50-M89 N/A Low temperature flexibility CGSB-37.50-M89 Pass • Alternate Substrates:Adequate structural support and the number,type Low temperature crack bridging CGSB-37.50-M89 Pass and location of fasteners required to meet applicable codes should be Heat stability in viscosity, ASTM E 154 Pass determined and verified by the project engineer. penetration,flow or low temp • Steel decking shall be 22 gauge minimum covered with 5/8" minimum flexibility after aging fire-rated Type X gypsum board or approved equal. Resiliency ASTM D3405 >60°i° Resistance to mild acids No effect • Wood decking shall be 1/2"minimum exterior grade tongue-and-groove Minimum ambient 0°F plywood installed with the long dimension perpendicular to joists.All temperature for application butt joints shall be supported by framing. Acid Resistance ASTM D896 50%Sulfuric Acid w/o blistering, deterioration,delamination or Warnings and Hazards re-emulsification Use with adequate ventilation.Workers must use proper protection to Sodium Chloride Resistance ASTM D896 Passed 20%Sodium Chloride w/o blistering,deterioration, prevent burns.Refer to the MSDS for important warnings and product delamination or re-emulsification information. Fertilizer Resistance ASTM D896 Passed 30/10/10 Fertilizer w/o blistering,deterioration, Packaging delamination or re-emulsification CCW-500 is packaged in 45-lb.blocks,one block per carton,64 cartons per pallet.Each block is sealed in a polyethylene bag inside the carton. Limited Warranty The block,including the bag, is placed in the kettle, leaving only disposal Carlisle Coatings&Waterproofing Incorporated(Carlisle)warrants this product of the carton. to be free of defects in workmanship and materials only at the time of shipment CCW-711-90 sheet membrane is packaged in roll sizes of 12"x 45' (45 from our factory.If any Carlisle materials prove to contain manufacturing defects sq.ft.), 18"x 45' (67.5 sq.ft.),24"X 45'(90 sq.ft.) and 36"x 45' (135 that substantially affect their performance,Carlisle will,at its option,replace the sq.ft.) materials or refund its purchase price.This limited warranty is the only warranty extended by Carlisle with respect to its materials.There are no other warranties, Standards including the implied warranties of merchantability and fitness for a particular purpose.Carlisle specifically disclaims liability for any incidental,consequential,or • US Patent#5,979,133 other damages,including but not limited to,loss of profits or damages to a structure • Canadian Specification CGSB-37.50-M89 or its contents,arising under any theory of law whatsoever.The dollar value of • UL 790 Class A Carlisle's liability and buyer's remedy under this limited warranty shall not exceed the purchase price of the Carlisle material in question. Carlisle Coatings&Waterproofing 900 Hensley Lane I Wylie,TX 75098 1800.527.7092 I www.carlisleccw.com 09.16.15©2015 Carlisle. Carlisle,Sure-Seal and FleeceBACK are trademarks of Carlisle. REPRINT CODE:600866-Vapor-Lock Technical Data Sheet DensDeck is a trademark of Georgia Pacific.