Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.688 Spruce St.0046-2022-BCHO (10)
.•. .•••• SILFAB PRIME ••• SIL - 370 HC S I L FA B • SOLAR •i RELIABLE ENERGY. DIRECT FROM THE SOURCE . Introducing Silfab Prime Designed to outperform. Koru-OK. Dependable, durable, high performance solar panels RE4EIVED engineered for North American homeowners. S I L FA B S O grJ'�' �i 12/08/2022 ❑I sus ® I EL A Fraunhofer c �o2o23 J �] • 'Chu���p^rq�,,� on insurance to Silfab SA EN Intertek Intertek ISE �yp{Nli�. /-\J L j imp BUILDING DEPARTMENT ELECTRICAL SPECIFICATIONS Test Conditions STC NOCT Module Power(Pmax) I Wp 370 267 Maximum power voltage(Vpmax) V 34.95 31.68 Maximum power current(Ipmax) A 10.60 8.43 Open circuit voltage(Voc) V 41.75 37.84 Short circuit current(Isc) A 11.25 8.94 Module efficiency % 20.2% 18.3% Maximum system voltage(VDC) V 1000 Series fuse rating A 20 Power Tolerance Wp 0 to+10 Measurement conditions:STC 1000 Who'•AM 1.5•Temperature 25°C•NOCT 800 W/m2•AM 1.5•Measurement uncertainty 2 3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+10W. •MECHANICAL PROPERTIES/COMPONENTS METRIC11111=11.111 IMPERIAL AIIIMII Module weight 20kg±0.2kg 441bs±0.41bs Dimensions(H x L x D) 1762 mm x 1037 mm x 35 mm 69.4 in x 40.8 in x 1.37 in Maximum surface load(wind/snow)' 5400 Pa rear load/5400 Pa front load 112.8 lb/ft^2 rear load/112.8 lb/ft^2 front load Hail impact resistance 0 25 mm at 83 km/h 01 in at 51.6 mph Cells 120 Half cells-Si mono PERC 120 Half cells-Si mono PERC 9 busbar-83 x 166 mm 9 busbar-3.26 x 6.53 in Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, DSM antireflective coating DSM antireflective coating Cables and connectors(refer to installation manual) 1350 mm,0 5.7 mm,MC4 from Staubli 53.15 in,0 0.22 in(12AWG),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film,fluorine-free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP67 rated WARRANTIES Temperature Coefficient Inc +0.064%/°C Module product workmanship warranty 25 years" Temperature Coefficient Voc -0.28%/°C Linear power performance guarantee 30 years Temperature Coefficient Pmax -0.36%/°C >_97.1%end 1st yr N 91.6%end 12th yr OCT(±2°C) 45°C >_85.1%end 25th yr Operating temperature -40/+85°C >_82.6%end 30thyr CERTIFICATIONS SHIPPING SPECS ULC ORD C1703,UL1703,CEC listed***,UL 61215-1/-1-1/-2"`,UL 61730-1/-2, Modules Per Pallet: 26 or 26(California) Product IEC 61215-1/-1-1/-2"`.IEC 61730-1/-2"',CSA C22.2#61730-1/-2"',IEC 62716 Ammonia Corrosion;IEC61701:2011 Salt Mist Corrosion Certifed,UL Fire Rating:Type 2 Pallets Per Truck 34 or 32(California) Modules Per Truck 884 or 832(California) " A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolar.com "* Certification anticipated May 2021. SILFAB SOLAR INC. I< c' 69.4"[1762mm] >I ff 800CornwallAve o E Bellingham WA 98225 USA n o.s"[lzmm x v T +1360.569.4733 a � >II o info@silfabsolar.com x= 53.15"[1350mm] 7 n m SILFABSOLAR.COM E 2' % ri c \ II_-__,E7)- o 0 240 Courtneypark Drive East m \\ MMississauga ON L5T 2Y3 Canada E E T +1905.255.2501 E E F +1905.696.0267 3 0 a N O v m u 1.4"[35mm] Silfab-SIL-370 HC m ,< >i No reproduction of any kind is allowed.Data !IT: , (7/ and information is subject to modifications - without notice.©Silfab 2020. w 3" 3 2 PAN files generated from 3rd party O 0.06"[1.5mm] performance /RE ED �i�"i< at:silfabsolar.colar.co m 1 F o o •s 2.4"[60mm] >113 V ENE 12/08/2022 8"[200mml < 02/02/2023 J <14"[356mm] >< 41.34"[1050mm] >< 14"[356mm] CDIXDOIY'IACE ASPEN j imp BUILDING DEPARTMENT Data Sheet Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready F' Enphase IQ 7A Micro' dramatically simplifies the IQ 7A M icroi nverter installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules. Part of the Enphase IQ System,the IQ 7A Micro integrates with the Enphase IQ EnvoyTM, Enphase IQ BatteryTM, and the Enphase Enlighten'"" monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) • Efficient and Reliable . • • Optimized for high powered 60-cell and 72-cell modules • Highest CEC efficiency of 97% = • More than a million hours of testing e,ENPHASE` r ^ u, • Class II double-insulated enclosure IQ7A �$ - WAJNING:.� - • UL listed IA Smart Grid Ready a'm s ova! m F • Complies with advanced grid support,voltage and frequency ride- through requirements • Envoy and Internet connection required • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) RECEIVED CERTIFIED Hytt SE To learn more about Enphase offerings,visit enphase.com �� EP22 02/02/2023 + MIIIIMINCE ASPEN i imp BUILDING DEPARTMENT Enphase IQ 7A Microinverter INPUT(DC) IQ7A-72-2-US Commonly used module pairings' 295 W-460 W+ Module compatibility 60-cell and 72-cell PV modules Maximum input DC voltage 58 V Maximum input DC current 10.2 A Peak power tracking voltage 38 V-43 V Operating range 18 V-58 V Min/Max start voltage 30 V/58 V Max DC short circuit current(module Isc) 15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; C side protec t requires max 20A per branch circuit OUTPUT(AC) @ 240 VAC @ 208 VAC Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Nominal(L-L)voltage/range2 240 V/211-264 208 V/183-229 V Maximum continuous output current . A(24 AC) 1.39 A(208 VAC) Nominal frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 11 (240 VAC) 11 (208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor(adjustable) 0.85 leading... 0.85 lagging EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.0% 96.5% MECHANICAL Ambient temperature range -40°C to+60°C Relative humidity range 4%to 100%(condensing) Connector type:DC(IQ7A-72-2-US) MC4 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2.Voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. RECEIVEDTo learn more about Enphase offerings,visit enphase.com CDWV L�2019 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc.Data sub e E NIB p"u /� 22 2019-08-07 ' "" � 02/02/2023 FORDauteumnota ASPEN j imp BUILDING DEPARTMENT Data Sheet Enphase Networking Enphase The Enphase IQ Commercial EnvoyTM gateway delivers solar production and energy consumption IQ Commercial Envoy data to Enphase EnlightenTM monitoring and analysis software for comprehensive, remote maintenance and management of three-phase Enphase IQ Systems. With integrated production metering and optional consumption monitoring,the Envoy IQ is the platform for total energy management and integrates with the IQ MicroinvertersTM and Enphase IQ Battery1M Smart EN PHASE • Enables web-based monitoring and control • Bidirectional communications for remote upgrades 4=0 • Supports power export limiting and zero- AIM - export applications -- rj CJ. Simple , • Easy system configuration using Enphase Installer Toolkit"mobile app • Flexible networking with Wi-Fi, Ethernet,or cellular Reliable • Designed for installation indoors or outdoors in an enclosure • Five-year warranty 143 RECEIVED LISTED CA III WL ENQ ►$ fl22 To learn more about Enphase offerings,visit enphase.com 02i02i2023 J RIAGODtCAJMHINICE ASPEN j imp BUILDING DEPARTMENT Enphase IQ Commercial Envoy MODEL NUMBERS Enphase IQ Commercial Envoy'° Three-phase communications gateway with integrated PV production metering(+/-0.5%) ENV-IQ-AM3-3P and optional consumption monitoring(+/-2.5%). Includes three 200A continuous rated production CTs. ACCESSORIES(order separately) Enphase Mobile Connect' Plug and play industrial grade cellular modem with five-year data plan(expandable to -CELLMODEM-M1 (4G LTE Category M1) 12 years)for systems up to 60 microinverters(expandable).Available in the US,Canada, -CELLMODEM-M1-B(4G LTE Category M1) Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in the installation area. Consumption Monitoring CTs Split-core current transformers enable consumption metering. CT-200-SPLIT(order three or six,as needed) POWER REQUIREMENTS Power requirements 208Y/120 VAC three-phase 220Y/127 VAC three-phase Max 20 A overcurrent protection required Typical Power Consumption 5W CAPACITY Number of microinverters polled Up to 300 MECHANICAL&ELECTRICAL DATA Dimensions(WxHxD) 21.3 x 12.6 x 4.5 cm(8.4"x 5"x 1.8") Weight 17.6 oz(498 g) Ambient temperature range -40°to 65°C(-40°to 149°F) -40°to 46°C(-40°to 115°F)if installed in an enclosure Environmental rating IP30.For installation indoors or in an NRTL-certified,NEMA type 3R enclosure. Altitude To 2000 meters(6,560 feet) Production CTs -Are limited to 200A of continuous current/250A OCPD—72kW AC -Allow for parallel connected CTs for up to 500A—144kW AC(if possible) -Internal aperture measures 19.36mm to support 250MCM THWN conductors(max) -Accuracy of+/-0.5%for production metering Consumption CTs -For electrical services to 250A with parallel runs up to 500A -Internal aperture measures 0.84"x 0.96"(21.33mm x 24.38mm)to support 3/0 THWN conductor -CT wire insulation rating of 600V -Accuracy of+/-2.5%for consumption monitoring INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable,not included Mobile Optional,CELLMODEM-M1 (LTE),CELLMODEM-01 (3G),or CELLMODEM-03(4G), not included COMPLIANCE Compliance UL 916 CAN/CSA C22.2 No.61010-1 47 CFR,Part 15,Class B,ICES 003 IEC/EN 61010-1:2010, EN50065-1,EN61000-4-5,EN61000-6-1,EN61000-6-2 To learn more about Enphase offerings,visit enphase.com RECEIVE ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Commercial Envoy,and other trademarks or service na Ole KA ,'E 1�P 22 trademarks of Enphase Energy,Inc.Data subject to change.07-12-2021 UU 02/02/2023 J FOR am comitima ASPEN j imp BUILDING DEPARTMENT Datasheet IRONRIDGE Flush Mount System r, *Confirm if available in black, or review alternate option to match nanels. Air Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance e Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty IVEDEntire system and components meet _ Twice the protection offer ,E a7 newest effective UL 2703 standard. co fi,tag rs_ D MOM' 12/08/2022 02/02/2023 m+ucomota ASPEN jimp Datasheet - XR Rails O XR10 Rail XR100 Rail XR1000 Rail Bonded Splices iliihli i A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish • Clear anodized finish • Forms secure bonding - Clamps & Grounding O — UFOs Stopper Sleeves Grounding Lugs Microinverter Kits -- t......... 1. �..—__ =ilowli— . Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount Mls or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled & lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • Sized to match modules • Single tool installation • Kit comes assembled • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 - Attachments O — FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs co 1 PA L �_ -A,...., _ Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System with superior waterproofing. attachment. to roof attachments. to various heights. • Twist-on Cap eases install • Secure rail connections • T& Square Bolt options • Works with vent flashing • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • 4" and 7" lengths • Mill and black finish • Clear and black finish • Assembled and lubricated • Ships assembled - Resources fETi Design Assistant NABCEP Certified Training AE�P$__ Go from rough layout to fully �' Earn free continuing education :edit; _ NABCEP D engineered system. For free. while learning more abouGo to IronRidge.com/design ��""`""°°`- Go to IronRidge.com/tr i �' D �� 12w 2 22 02/02/2023 d + 601161.1MICE A N im• iimirj ©2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.30 POWERWALL Tesla Powerwall 2 is a fully-integrated AC battery system for -r = 55 I_ n residential or light commercial use. Its rechargeable lithium-ion battery pack provides energy storage for solar self-consumption, load shifting, and off-grid use. Powerwall's electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage(Nominal) 208 V,220 V,230 V, Dimensions 1150 mm x 755 mm x 155 mm 100/200 V,120/240 V (45.3 in x 29.7 in x 6.1 in) Feed-In Type Single&Split Phase Weight 125 kg(276 Ibs) Grid Frequency 50 and 60 Hz Mounting options Floor or wall mount Total Energy' 14 kWh Usable Energy' 13.5 kWh ENVIRONMENTAL SPECIFICATIONS Real Power,max continuous2 5 kW(charge and discharge) — Operating Temperature -20°C to 50°C(-4°F to 122°F) Real Power,peak(10s)2 7 kW(discharge only) Operating Humidity(RH) Up to 100%,condensing Apparent Power,max continuous2 5.8 kVA(charge and discharge) — Maximum Altitude 3000 m(9843 ft) Apparent Power,peak(10s)2 7.2 kVA(discharge only) Environment Indoor and outdoor rated Imbalance for Single-Phase Loads 100% Enclosure Type NEMA 3R Power Factor Output Range +/-1.0 adjustable Ingress Rating IP67(Battery&Power Electronics) Power Factor(full-rated power) +/-0.85 IP56(Wiring Compartment) Depth of Discharge 100% Noise Level @ 1 m <40 dBA at 30°C(86°F) Internal Battery DC Voltage 50 V Round Trip Efficiency',3 >90% Warranty 10 years ENERGY GATEWAY SPECIFICATIONS 'Values provided for 25°C(77°F),3.3 kW charge/discharge power. Dimensions 240 mm x 243 mm x 130 mm 2Values region-dependent. (9.5 in x 9.5 in x 5.1 in) 'AC to battery to AC,at beginning of life. Weight 2 kg(4.5 Ibs) COMPLIANCE INFORMATION Enclosure Type NEMA4 Ingress Rating IP65 Safety UL 1642,UL 1741,UL 1973, UL 9540,UN 38.3,IEC 62109-1, User Interface Tesla App IEC 62619,CSA C22.2.107.1 Connectivity Wi-Fi,Ethernet,3G4 Grid Standards Worldwide Compatibility AC Meter Revenue grade Emissions FCC Part 15 Class B,ICES 003, EN 61000 Class B Operating Modes Support for solar self-consumption, load shifting,and off-grid use Environmental RoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, Modularity Supports up to 10 AC-coupled Powerwalls 2006/66/EC '3G optional Seismic AC156,IEEE 693-2005(high) RECEIVED rg-02/02/202312/08/2022 T-5Ln GOIXC(1 i'IACE j imp TESLA.� GY ����yy BUILDING DEPARTMENT TYPICAL SYSTEM LAYOUT Optional 127' Solar panel 0 0 1. Solar inverter •o 0 Main panel Utility meter T = 5 L F Energy Gateway non Powerwall Home loads RECEIVED mewireD 12/08/2022 T-5 L n 02/02/2023 J COIXC(1 i'1111NCE j imp TESLA.. GY ����yy BUILDING DEPARTMENT POWERWALL Backup Gateway 2 The Backup Gateway 2 for Tesla Powerwall provides energy management ; L and monitoring for solar self-consumption,time-based control,and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker,the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage(Nominal) 120/240V Dimensions 660 mm x 411 mm x 149 mm Feed-In Type Split Phase (26 in x 16 in x 6 in) Weight 20.4 kg(45 lb) Grid Frequency 60 Hz Mounting options Wall mount,Semi-flush mount Current Rating 200 A Maximum Input Short Circuit Current 10 kA' Overcurrent Protection Device 100-200A;Service Entrance Rated' rm, Overvoltage Category Category IV AC Meter Revenue accurate(+/-0.2%) Primary Connectivity Ethernet,Wi-Fi T S. S IL R Secondary Connectivity Cellular(3G, LTE/4G)2 User Interface Tesla App Operating Modes Support for solar self-consumption, 660 time-based control,and backup Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC-coupled Powerwalls Optional Internal Panelboard 200A 6-space/12 circuit Eaton BR Circuit Breakers Warranty 10 years 'When protected by Class J fuses,Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 411 149 2 The customer is expected to provide internet connectivity for Backup Gateway 2;cellular should not be used as the primary mode of connectivity.Cellular connectivity subject to network operator service coverage and signal strength. COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS Certifications UL 67,UL 869A,UL 916,UL 1741 PCS Operating Temperature -20°C to 50°C(-4°F to 122°F) CSA 22.2 0.19,CSA 22.2 205 Operating Humidity(RH) Up to 100%,condensing Emissions FCC Part 15, ICES 003 Maximum Elevation 3000 m(9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R REE1\(ED rrat 12/08/2022 02/02/2023 JJ TESL n NA 2020-05-23 CAJWINCE TESLA.C,�OMLE GY j imp A r��N BUILDING DEPARTMENT