HomeMy WebLinkAboutFile Documents.105 Exhibition Ln.0008-2024-BROF (7) NW CLIENT PROVIDED INFO a
SHEET INDEX BRACKET TYPE: N/A N
CP - Cover Page DECK SHEATHING: N/A ==
VERTICAL EXPOSURE: NIA C/4 w g'
0 0 SR- Snow Retention Sheets HORIZONTAL EXPOSURE: N/A 043 e L
CLAMP-ON TYPE: C22
DT-Detail Sheets EXHIBITION I TIJIV 105 LANE PANEL WIDTH:
RIB HEIGHT: 1.5' Q
16"OC W t
SEAM TYPE: DOUBLE LOCK == ° -2
GENERAL NOTES DECK MOUNT TYPE: NIA Co)_ z o
MOUNT SPACING: N/A ¢ y
SNOW RETENTION
ASPEN CO ROOFING MAT'L: STANDING SEAM , -65
GROUND SNOW LOAD: 120 PSF
1. Snow Bracket/Snow Fence layout has been w
engineered for this specific roof application.Any PROJECT LABELS NW_ oS
deviation from the prescribed layout will void the PD1:C22 CLAMP-ON(SEE DT1.0 PAGE)
product or system warranty.
2. Install Snow Brackets/Snow Fence per W 2
specifications and details provided by TRA Snow a
and Sun. Installer is responsible for the correct REVISIONS
installation of all snow retention system
components. cl
3. Installer shall check existing job site conditions N
and dimensions prior to installation. Installer shall M
report any discrepancies or conflicts to TRA Snow PROJECT NOTES Q o
and Sun prior to commencing work. z 0-
4. Drawings and quotes are based upon information 1.ALL C22 SNOW EAVE COURSES TO BE o I-w
INSTALLED 12"FROM EAVE U.N.O. ¢o
provided by the customer to TRA Snow and Sun. m
TRA Snow and Sun is not liable for any w
CCw
information that is found to be incorrect or false. o 0
5.Any snow bracket quantity shown is for Q0
CO
estimating purposes only and is based on the w w
CC CC
calculated number of snow brackets per roofing
square. Installer is responsible to verify proper STAMP
snow bracket quantity based on actual number of ��
�
roofing squares. 3/21/2024
6.All structures are to be checked for code '°p'
compliance by the customer. _ABBREVIATIONS NW
7. Once every two years, check torque of the snow PD-PROJECT DETAIL W
fence carriage bolts and locking nuts, making sure
LD
30 foot pounds of torque is still applied. Once LAYOUT DETAIL Q
every year perform visual inspection. Z
U
� mO w°
d
111111
DISCLAIMERS w Q
o
A. These drawings are the property of TRA Snow and Sun and
any reuse or further distibution thereof in part or in whole E
without written consent from TRA Snow and Sun is prohibited. E
Drafter is not an architect or engineer. w DRAWN BY: MR
L8 Tv,Ei: -iii i r ir,4\
B.Any change to this layout will result in the need for 1
additional parts and costs above the original quote.Any
additional part costs will be paid by the client and are not the responsibility of TRA Snow and Sun. M ?2140Q 4
0
CVSHEET 1 OF 3
0 March kORk.N
_DING DEPAR-iZv1FNT
SNOW RETENTION PART SCHEDULE —
PLAN LEGEND PART/DESC QTY CLIENT PROVIDED INFO
BRACKET TYPE: N/A
C22 CLAMP-ON 653 DECK SHEATHING: NIA =
BCLAMP ON SNOW
SNOW FENCE A BRACKET CLAMP-ON PIPE L=10' 176 VERTICAL EXPOSURE: NIA C)« o
CLAMP-ON CAPS/COLLARS 315 HORIZONTAL EXPOSURE: N/A
7
SNOW FENCE \% EXPANSION CLAMP-ON TYPE: C22
DECK MOUNT GAP PANEL WIDTH: 16"OC
E
'-
RIB HEIGHT: 1.5" Q U
SEAM TYPE: DOUBLE LOCK == 2 a
0 ICE FLAG DECK MOUNT TYPE: NIA ��
5'-1" MOUNT SPACING: N/A Ea
¢ ‘-::y
TYP ROOFING MATL: STANDING SEAM LL,
*RECOMMENDED PART SCHEDULE GROUND SNOW LOAD: 120 PSF 0,,,:
PART/DESC QTY 2w
_ ICE FLAG(1 @ EACH SPACE) 290 PROJECT LABELS —
ai:ti m _ _ _
- - r m _ _ _ , PD1:C22 CLAMP-ON(SEE DT1.0 PAGE) \`= -
e a ma a 9 9 9 9 9 e e e e 0
- 4'-4/2" m _ W TYP - - - p Et_ m _ , , , 9 9 A X 1R p 'e e a _ _ *TRA RECOMMENDS THE USE OF ICE a
m
- 1 T■ B4 a a - m _ FLAGS FOR ROOFS WITH A SLOPE REVISIONS
8,_83/4„ 6-6„ 5'-1" 4'-1" UNDER 2:12,A SEAM PROFILE OF 1"OR
\/\- -
a s t, a a a a a a a a a a NA m _ GREATER, AND SNOW LOADS OF 30 PSF
/N "/
m OR LESS. RECOMMENDED TO BE N
INSTALLED ON EAVE COURSES. N
M
i - — 40'O" _ - PROJECT NOTES o
e I e e; m FLAT — - FLAT 1.ALL C22 SNOW FENCE EAVE COURSES TO BE o:
J m (::
INSTALLED 12"FROM EAVE U.N.O. ¢oa a a aJ m 8:12TYPU.N.O. _ m
- -
3'9 4' , - - - L
' eee ' ' ' ' ' ee " m m _ _ Q
▪ _ 3'8 a„ T 1"TYP -+ - T P - 8'-11 4„ y f 3,2„ '¢
▪ - [ TYP I ' - - - - ww
1 1 q - m I + CC LC
1 m _ a a a a e e 4:12 _
y - - s'6/2„T 1.- _ - m STAMP
▪ m e 4'-53 4" I m e e-e e-e e e e e e m
-
3/21/2024
_ m I „ 4:12 TYP 'VW
- m m m 210/a m _
r. ABBREVIATIONSNW
- - j - 2 10 2„ �{ m i : : TYP PD PROJECT DETAIL z
- TYP PD1 LD-LAYOUT DETAIL Q
- - _ m 4'-114„
-
-
- - - - o O
4'-3" z
— Eaw
- - : N► m
- -
- m w
_ - - DUE TO SOLAR PANELS INTERFERING WITH THE SNOW RETENTION 0, o
- - - - INSTALLATION WITH TRA SNOW AND SUN'S ENGINEERING STANDARDS, -6
2-3 THIS SECTION WILL NOT BE WARRANTED BY TRA SNOW AND SUN. ._
E
- - ill DRAWN BY: MR
2 APPROVED: CHK'D ,re)
3'7°TYP PRODUCT DETAIL AND INSTALL
INFORMATION: https://trasnowandsun.com/product/c22z-clamp-on/ M '/28/`YOQ4
SNOW RETENTION PLAN
SHEET 2 OF 3
3/32" = 1 r_0►r March AMEN
._,DING DEPARTMENT
CLIENT PROVIDED INFO Niwr g
U
BRACKET TYPE: N/A =: (1
DECK SHEATHING: N/A =E m
VERTICAL EXPOSURE: NIA C )» cg 3
o
HORIZONTAL EXPOSURE: N/A z
CLAMP-ON TYPE: C22
PANEL WIDTH: 16"OC 3 W g
RIB HEIGHT: 1.5" =Z L. y
SEAM TYPE: DOUBLE LOCK =: L m
DECK MOUNT TYPE: NIA CI): g o
MOUNT SPACING: N/A ¢ y
_ROOFING MAT'L: STANDING SEAM LL,
GROUND SNOW LOAD: 120 PSF
u -
PROJECT LABELS
PDI:C22 CLAMP-ON(SEE DTI.0 PAGE) co
- ,6
i "'
W
a
REVISIONS
•PEMOST NOT WEND MORE N
THPN1 YPAOi THE FINALCUMP-0N
lell
N_
OLARS TO DE PLACED Ch
/ INSIDE.CLAMP-ON
aMMDEEOLT r�i �C"�°°"NEPIPE PROJECT NOTES Q-
uj'Z
Oilit
E fIAG
iii,
t \ .
1.ALL C22 SNOW FENCE EAVE COURSES TO BEo I-'„LU
o� ' �� INSTALLED 12"FROM EAVE U.N.O. <o
N
Iw
LU
GIAMPTHE SNOW FENCERITHERIR BY 3/
18
DERCPLATED L
POW GOATEDSTFFL Q m
USING ATORE/1 1ENGI.B Ff-LBS.
FOR SPESMREENGINEDTOEAN SOLI. J
Of W W
FOR SPECIFIC ENGINEERING EERINOANDPLACEMENT CALL LU
TRAsuowAu°sux leopTscesss
STAMPCC CC
�` �`�I
Icl
C22 SNOW FENCE5411 V 41°IiiiHj
®NO SCALE 3/21/2024
ABBREVIATIONS
PD-PROJECT DETAIL Wfry
LD LAYOUT DETAIL Q
J
lil z o
O �
' �Lo
00 w
d
_ `�
? Q
W
� o
0
1E
w DRAWN BY: MR
o
AP V : ' D
. :,%,. 4
PT2140Q 4
(.1 SHEET 3 OF 3
N March 14S2RE N
BU LDING DEPARTMENT