HomeMy WebLinkAboutFile Documents.800 S Mill St.0018-2024-BRES (6)RENOVATE
SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
2021 IBC Code References
L 100% of lamps in permanently installed lights must be high efficacy, Ordinance 1, 2023.
AS Access and service space for maintenance required, 2021 IMC 306
CO Carbon monoxide detector required per Aspen Municipal Code 8.15
DE Clothes dryer exhaust, 2021 IMC 504. Makeup air required if over 200 CFM
SE Continuous air barrier required; all exterior joints, cracks, and holes to be caulked, gasketed, sealed, Ordinance 1, 2023
DV Direct vent sealed combustion required, Ordinance 1, 2023
EP Electric panel happy space: 30in x 36in x 78in, not in storage, NEC 110.26
EE Emergency escape and rescue opening required 2021 IBC 1031
ET Exhausts terminate 3ft from prop line and openings, 10ft from intakes, 2021 IMC 501.3.1
GR Guards, 42in min high, 4in max opening. Guards within dwelling unit 36in min high 2021 IBC 1015
HR Handrails 34in-38in high, 2021 IBC 1014
IT Intake openings 10ft from lot line & contaminant sources (vents, streets), 2021 IMC 401.4
MA Make up air required if hood exhausts greater than 400 CFM, 2021 IMC 505.4
V Mechanical ventilation required, Ordinance 1, 2023
F New or replacement fenestration in existing residential buildings shall not exceed 0.28 U-factor, NFRC label required, Ordinance 1, 2023
SG Safety glazing required, 2021 IBC 2406
SA Smoke alarm per NFPA 72 required, 2021 IBC 907.2.11
WFP Window fall protection- operable window less than 24in AFF and greater than 72in above exterior grade: use opening control device listed to ASTM F2090, 2021 IBC 1015.8
100% of lamps in
permanently installed light
fixtures must be high efficacy
- IECC R404.1
0018-2024-BRES
CHILDS INVESTMENT COMPANY
800 S MILL ST 305A
273718276011
11/15/2023
02/20/2024
04/16/2024
linzhid
FIRE RATED HATS &
CEILING RADIATION DAMPERS
REQUIRED
Where floor/ceiling or roof/ceiling assemblies
are required to have a fire-resistive rating,
recessed fixtures shall be installed such that
the required fire resistance will not be reduced.
Ducts and air transfer openings penetrating the
ceiling of a fire rated ceiling assembly must be
protected with a listed ceiling radiation damper.
This includes bathroom exhaust fans.
(IBC 714.4.2 & 717.6.2)