HomeMy WebLinkAboutFile Documents.800 S Mill St.0018-2024-BRES (6)RENOVATE SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. 2021 IBC Code References L 100% of lamps in permanently installed lights must be high efficacy, Ordinance 1, 2023. AS Access and service space for maintenance required, 2021 IMC 306 CO Carbon monoxide detector required per Aspen Municipal Code 8.15 DE Clothes dryer exhaust, 2021 IMC 504. Makeup air required if over 200 CFM SE Continuous air barrier required; all exterior joints, cracks, and holes to be caulked, gasketed, sealed, Ordinance 1, 2023 DV Direct vent sealed combustion required, Ordinance 1, 2023 EP Electric panel happy space: 30in x 36in x 78in, not in storage, NEC 110.26 EE Emergency escape and rescue opening required 2021 IBC 1031 ET Exhausts terminate 3ft from prop line and openings, 10ft from intakes, 2021 IMC 501.3.1 GR Guards, 42in min high, 4in max opening. Guards within dwelling unit 36in min high 2021 IBC 1015 HR Handrails 34in-38in high, 2021 IBC 1014 IT Intake openings 10ft from lot line & contaminant sources (vents, streets), 2021 IMC 401.4 MA Make up air required if hood exhausts greater than 400 CFM, 2021 IMC 505.4 V Mechanical ventilation required, Ordinance 1, 2023 F New or replacement fenestration in existing residential buildings shall not exceed 0.28 U-factor, NFRC label required, Ordinance 1, 2023 SG Safety glazing required, 2021 IBC 2406 SA Smoke alarm per NFPA 72 required, 2021 IBC 907.2.11 WFP Window fall protection- operable window less than 24in AFF and greater than 72in above exterior grade: use opening control device listed to ASTM F2090, 2021 IBC 1015.8 100% of lamps in permanently installed light fixtures must be high efficacy - IECC R404.1 0018-2024-BRES CHILDS INVESTMENT COMPANY 800 S MILL ST 305A 273718276011 11/15/2023 02/20/2024 04/16/2024 linzhid FIRE RATED HATS & CEILING RADIATION DAMPERS REQUIRED Where floor/ceiling or roof/ceiling assemblies are required to have a fire-resistive rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced. Ducts and air transfer openings penetrating the ceiling of a fire rated ceiling assembly must be protected with a listed ceiling radiation damper. This includes bathroom exhaust fans. (IBC 714.4.2 & 717.6.2)