HomeMy WebLinkAboutFile Documents.801 E Hopkins Ave.0150-2023-BRES (18)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
luisp
12/13/2023ZONING
100% of lamps in
permanently installed light
fixtures must be high efficacy
- IECC R404.1
FIRE RATED HATS &
CEILING RADIATION DAMPERS
REQUIRED
Where floor/ceiling or roof/ceiling assemblies
are required to have a fire-resistive rating,
recessed fixtures shall be installed such that
the required fire resistance will not be reduced.
Ducts and air transfer openings penetrating the
ceiling of a fire rated ceiling assembly must be
protected with a listed ceiling radiation damper.
This includes bathroom exhaust fans.
(IBC 714.4.2 & 717.6.2)
Existing Fireplaces and Woodstoves:
-If you propose to alter the firebox of a fireplace or move a
fireplace, it shall be removed or replaced with a gas direct
vent or electric appliance.
-Conversion to or replacement with gas log is prohibited.
-New or replacement gas fireplaces are subject to REMP.
-If you propose to move or alter a woodstove, it shall be
removed or replaced with a department certified woodstove.
To verify fenestration U-factors, the following is
REQUIRED PRIOR TO GLAZING INSPECTION:
Factory built windows:
An NFRC label must be affixed to the window assembly and
verified at field inspection.
Site built windows:
A certificate of authorization from an NFRC authorized inspection
agency has been received and approved. Project specific NFRC
labels must be affixed to the units or a project specific NFRC
label certificate must be provided prior to field inspection.
Site built windows:
ASHRAE calculations were approved. To document the chain of
custody, an affidavit or other evidence from the manufacturer
confirming compliance with the calculations are required
prior to field inspection.
Site built windows:
A simulation by an NFRC–accredited lab in accordance with
NFRC-100 has been approved. Verification labels must be
affixed to the window units by an accredited independent
inspection agency or a certificate, affidavit or other evidence
from the manufacturer confirming compliance with the
NFRC-100 simulation or testing must be provided for
approval prior to inspection.
READ THIS OR FAIL YOUR INSPECTION!
Dropped Ceilings and Soffits beneath fire rated
assemblies
2021 IBC 803.13
This applies to the attachment of finishes or furring to any
assemblies that are required to be either fire-rated or
non-combustible and is separate from the fire-rated
assembly requirement.
1. Dropped Ceilings & Soffits: If dropped 1 ¾
inches or less, do one of the following:
-Fill spaces with Class A material.
-Fill spaces with inorganic or non-combustible material.
-Fire block 8 feet in all directions.
2. Dropped Ceilings & Soffits: If dropped greater
than 1 ¾ inches:
Framing members, hangers, and other assembly
members must be non-combustible. You may not
use wood.
In Type III and V construction only, you may use fire
retardant treated wood or non-combustible framing.
3. Dropped Ceilings & Soffits below Heavy
Timber T&G ceilings, do all of the following:
-One layer 5/8” type X gypsum board directly
attached with minimum level one finish.
-Drop ceiling according to item 1 or 2 above as
applicable.
(City Policy)
01/12/2024
linzhid
0150-2023-BRES
TETSUYAMA LLC
801 E HOPKINS AVE 5
273718208011
HEALTHSAFE CONCLUSIONS
• There is friable asbestos in the sheet vinyl flooring in the upper-level laundry
closet that shall require a State-certified and State-permitted asbestos
abatement contractor to abate.
Asbestos abatement and clean air report required before
work begins