HomeMy WebLinkAboutFile Documents.801 E Hopkins Ave.0150-2023-BRES (18)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. luisp 12/13/2023ZONING 100% of lamps in permanently installed light fixtures must be high efficacy - IECC R404.1 FIRE RATED HATS & CEILING RADIATION DAMPERS REQUIRED Where floor/ceiling or roof/ceiling assemblies are required to have a fire-resistive rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced. Ducts and air transfer openings penetrating the ceiling of a fire rated ceiling assembly must be protected with a listed ceiling radiation damper. This includes bathroom exhaust fans. (IBC 714.4.2 & 717.6.2) Existing Fireplaces and Woodstoves: -If you propose to alter the firebox of a fireplace or move a fireplace, it shall be removed or replaced with a gas direct vent or electric appliance. -Conversion to or replacement with gas log is prohibited. -New or replacement gas fireplaces are subject to REMP. -If you propose to move or alter a woodstove, it shall be removed or replaced with a department certified woodstove. To verify fenestration U-factors, the following is REQUIRED PRIOR TO GLAZING INSPECTION: Factory built windows: An NFRC label must be affixed to the window assembly and verified at field inspection. Site built windows: A certificate of authorization from an NFRC authorized inspection agency has been received and approved. Project specific NFRC labels must be affixed to the units or a project specific NFRC label certificate must be provided prior to field inspection. Site built windows: ASHRAE calculations were approved. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the calculations are required prior to field inspection. Site built windows: A simulation by an NFRC–accredited lab in accordance with NFRC-100 has been approved. Verification labels must be affixed to the window units by an accredited independent inspection agency or a certificate, affidavit or other evidence from the manufacturer confirming compliance with the NFRC-100 simulation or testing must be provided for approval prior to inspection. READ THIS OR FAIL YOUR INSPECTION! Dropped Ceilings and Soffits beneath fire rated assemblies 2021 IBC 803.13 This applies to the attachment of finishes or furring to any assemblies that are required to be either fire-rated or non-combustible and is separate from the fire-rated assembly requirement. 1. Dropped Ceilings & Soffits: If dropped 1 ¾ inches or less, do one of the following: -Fill spaces with Class A material. -Fill spaces with inorganic or non-combustible material. -Fire block 8 feet in all directions. 2. Dropped Ceilings & Soffits: If dropped greater than 1 ¾ inches: Framing members, hangers, and other assembly members must be non-combustible. You may not use wood. In Type III and V construction only, you may use fire retardant treated wood or non-combustible framing. 3. Dropped Ceilings & Soffits below Heavy Timber T&G ceilings, do all of the following: -One layer 5/8” type X gypsum board directly attached with minimum level one finish. -Drop ceiling according to item 1 or 2 above as applicable. (City Policy) 01/12/2024 linzhid 0150-2023-BRES TETSUYAMA LLC 801 E HOPKINS AVE 5 273718208011 HEALTHSAFE CONCLUSIONS • There is friable asbestos in the sheet vinyl flooring in the upper-level laundry closet that shall require a State-certified and State-permitted asbestos abatement contractor to abate. Asbestos abatement and clean air report required before work begins