HomeMy WebLinkAboutFile Documents.137 Westview Dr.0141-2023-BRES (7)G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc
over
City of Aspen and Pitkin County
FIREPLACE & WOODSTOVE REGISTRATION
*Required—Contact Assessors offices at 920-5160
Registration will not be accepted without a Parcel Id number
List all devices in your home (2 are allowed per building, except for gas appliances)
Note: If the number, type and location on this registration form do not match what is show on your plans or what is actually
installed, your permit or Certificate of Occupancy will be denied.
Type of Building (circle one): Reside ntial Other
Type of device Room Existing New Make & Model
Wood burning fireplace (select one)
?Site-built masonry
?Factory built insert: model
number:
_____________________
Gas log fireplace (select one)
?Site-built masonry
?Factory built insert: model
number:
_____________________
Certified woodstove
Gas fireplace appliance
(attach spec sheet)
If any devices are being removed, please describe here, i.e. “old woodstove removed from living room”
· __________________________________________________________________________________
· __________________________________________________________________________________
· __________________________________________________________________________________
_______________________________________________________ ____________________________
Signature of applicant Date
*Parcel Id number:____ ____ ____ ____ -- ____ ____ ____ -- ____ ____ -- ____ ____ ____
Street Address:_________________________________________________________________________
Owners Name:_________________________________________________________________________
2 7 3 7 1 8 1 2 1 0 0 6
137 Westview Drive
LPI Westview LLC
Living yes
Golden Blount HD5030-TV
Mstr Bed replacement Heat n Glo Mezza 60
Removing and abandoning existing gas appliance in existing Sitting Rm 205
Master Bed existing gas appliance fireplace is being replaced with new gas appliance fireplace
8.07.23
11/17/2023
HD5030-TV is a decorative gas fireplace, not a gas log fireplace.
G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc
over
ASPEN/PITKIN COUNTY FIREPLACE AND WOODSTOVE REGULATIONS
In order to keep our air as clean as possible, the elected officials of Aspen and Pitkin County have passed ordinances to regulate the
number of fireplaces and woodstoves that can be installed in any building. Building permit applicants must file a
fireplace/woodstove registration with the City of Aspen Building Department or the Pitkin County Building Department before the
building permit is issued.
Pitkin County is separated into 2 areas. One is the non attainment area, which includes the City of Aspen and the Metropolitan
areas of the county, i.e. Mountain Valley, Red Mountain, Difficult Ca mpground, T Lazy 7 Ranch, and part of Starwood. The other
is the attainment area which includes the less densely populated parts of the county, i.e. Brush Creek Village, Holland Hills and
Old Snowmass.
Decorative gas appliance: A device utilizing natural gas as a fuel gas designed to appear as a real fireplace with a 4 to 5 inch Class
B vent or direct vent, fixed glass door and a firebox no deeper than 24 inches.
Certified Woodstove: Colorado Phase III certified woodstove or a Phase II EPA certified woodstove.
Gas log fireplace: Meet all codes for burning wood but are used with gas logs. They are not allowed in bedrooms.
Aspen and Metropolitan Areas of Pitkin County in the non attainment area
New buildings in the non attainment area may have either 2 gas log fireplace or 2 certified woodstoves or 1 each. They may also
have an unlimited number of decorative gas appliances. Wood burning fireplaces cannot be installed, nor may coal be used as fuel.
Remodeling or an addition to an existing home in the non attainment area
· If the building has 2 or more fireplaces, gas log fireplaces or woodstoves, they only devices you can add are decorative gas
appliances.
· If the building has 1 fireplace, gas log fireplace or woodstove, you may add 1 gas log fireplace and an unlimited number of
decorative gas appliances.
· If a building has more than 2 fireplaces, gas log fireplaces; if one is affected by the remodel it must be removed.
· If a building has only 1 or 2 fireplaces, woodstoves or gas log fireplaces, please keep in mind:
o If you alter the firebox of a fireplace, it must be converted to gas logs or removed.
o If a woodstove is moved, it must be removed or replaced with a department certified woodstove.
Attainment Area in Pitkin County
New residential buildings in this area may have one wood burning fireplace and one gas log or certified woodstove. If there is no
fireplace, you may have either 2 gas log fireplaces or 2 certified woodstoves or 1 each. Buildings may also have an unlimited
number of decorative gas appliances.
Remodeling or an addition to an existing building in the attainment areas
· If the building has 2 or more fireplaces or woodstoves, the only devices you can add are decorative gas appliances.
· If you have 1 fireplace or woodstove, you may add 1 gas log or certified woodstove and an unlimited number of decorative
gas appliances
· If a building has more than 2 fireplaces or woodstoves: if one is affected by a remodel, it must be removed
· If a building has on 1 or 2 fireplaces, woodstoves or gas log appliances, please keep in mind:
o If a woodstove is moved, it must be removed or replaced with a department certified device.
o If you alter the firebox of a fireplace, and already have another fireplace, it must be converted to gas log
Non residential buildings (which include commercial buildings, restaurants, lodges, public buildings, and hotels) in the attainment
area of Pitkin County are allowed to have gas appliances.
11/17/2023
Specifications
Additional information can be found online at www.heatnglo.com
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
Actual Framing Actual Framing Actual Framing Actual Framing
8-9/16" [218]
1" [25]70" [1778]
17-1/8"[435]
18-5/8"[473]
oCENTERED ON APPLIANCE
8" [203]
47-3/4" [1213]
2-3/8"[60]
8-9/16"[218]2-3/4"[70]
23-3/4"[603]
36-5/8"[930]
63-1/8" [1603]
74" [1880]
15-5/8" [397]
48-1/2"[1232]
24-1/2"[622]
8-7/8" [225]
7-1/4"[184]GAS ACCESS ELECTRICAL ACCESS
4" [102]
8-9/16" [218]
63" [1600]
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MEZZO60
60" Direct Vent Gas Fireplace
MEZZO60
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
MEZZO60 Actual Framing Actual Framing Actual Framing Actual Framing 59-1/2 x 12-1/27072-1/4 70 72-1/4 47-3/4 48 17-1/8 18-1/4
Top
FrontLeft Right
BEFORE FRAMING, PLEASE NOTE:
A minimum of 18" of vertical venting is required before attaching any elbow to the appliance.
11/17/2023
MEZZO60Decorative Fronts Dimensions and Framing
FRONT DIMENSIONS
FINISHED OPENING DIMENSIONS
Clean Face Trim
Inside Fit Method
(Clean Face Trim)
Overlap Fit Method
(Loft Forge, Quattro)
Loft Forge Front Quattro Front
• Rectangular holes on
bottom of access panel
should be covered.
• Approved for 0"-4"
finishing material on inside
fit method
• If finishing materials are 0-1”
thick, the outer trim ring
should be adjusted out so
that the trim ring overlaps
the finishing material. This
is intended to provide the
cleanest look.
• If finishing materials are 1-4”
thick, install the trim ring
all the way in. Finishing
materials may not extend
past the outside edge of
the trim ring.
• Rectangular holes on
bottom of access panel
must be exposed.
• ONLY approved for 0"-1"
finishing material on
overlap fit method
• Rectangular holes on
bottom of access panel
must be exposed.
• ONLY approved for 0"-1"
finishing material on
overlap fit method
25"[635]
24"[610]
13-1/8"[333]16-3/4"[425]
64-5/16" [1634]
63" [1600]
61-3/16" [1554]
5/8" [16]
26-1/4"[667]
7-1/8"[181]
60-3/4" [1543]66-3/4" [1695]
13"[330]
19"[483]27-1/4"[692]
5-7/8"[149]
60-9/16" [1538]
69-1/8" [1756]
12-1/2"[318]
21-3/8"[543]
52-1/2" [1334]
FIREPLACE VIEWING AREA
15-3/4"
[400]
63-1/8" [1603]
FIREPLACE VIEWING AREA17-1/4"
[438]
63-1/8" [1603]
11/17/2023
Specifications
GS/HNG/MEZZO60_0420
PRODUCT LISTING CODES
US ANSI Z21.88-2017
CAN CSA 2.33-2017
UL307B
Additional information can be found online at www.heatnglo.com
Product information provided is
not complete and is subject to
change without notice. Product
installation must adhere strictly
to instructions accompanying
product to avoid risk of fire and
potential injury.
Lakeville, MN Web: heatnglo.com
Phone: 888-427-3973 952-985-6000
MEZZO60
FRAMING DIMENSION
CLEARANCES TO COMBUSTIBLES
APPLIANCE LOCATION
112-3/8"[2854]
79-1/2"[2019]72-1/4[2013]**
72-1/4[2013]**
72-1/4 [2013]**
72-1/4 [2013]**
18-3/4"[476]
31-3/4"[807]1"[25]
1"[25]
See clearancesin install manualRefer to install manual for hearth, mantel and wall projection information.
If a Passive Heat, Heat-Zone or Heat Out will be installed, refer install manual for instructions.
18 in. (457 mm) required when Passive Heat Side Discharge Kit is installed. Refer to the Passive Heat kit instructions for more information.
MANTEL LEG/WALL PROJECTIONS
COMBUSTIBLE OR NON-COMBUSTIBLE
WALL PENETRATION
3 ft. maximum
4-1/2"
minimum
FIREPLACE OPENING
See Appliance dimension diagram
in install manual - Dimension B
Note: Clearance from
opening to
perpendicular wall
Top View
FIREPLACE OPENING
See Appliance dimension diagram
in install manual - Dimension B
Note: Clearance from
opening to
perpendicular wall
Top View
7"
minimum UNLIMITED
Acceptable on both sides of opening
64"
[1626]
10"12"
63"
[1600]
Do not pack withinsulation orother material
* Shows center of vent framinghole for top venting. Center of holeis 1" [25] above center of horizontalvent pipe.
48"[1219]
72-1/4"[1835]
10"[254]
HEADER
DEPTH**
18-1/4"[464]
APPLIANCE MAY BE INSTALLED OFF OF FLOOR***
* Adjust framing dimensions for interior sheathing (such as sheetrock)
** Header depth not to exceed 3-1/2".
*** If appliance is installed off the floor, maintain required clearances to combustibles
Construct platform in accordance with local building codes.
48"[1219]
0"
1" [25]
1" [25]
31" [787]Top ofFireplaceOpening toCeiling
0"
55-1/2"[1410]Bottom ofFireplace toCeiling
MANTEL PROJECTIONS - NON-COMBUSTIBLE
MANTEL PROJECTIONS - COMBUSTIBLE
OVERLAP FIT INSIDE FIT
MEASUREMENTS FROM TOP EDGE
OF THE APPLIANCE OPENING
4
5
6
16
3
2
1
6
7
8
9
10 11
18
MAX.
Measurement from top edge of opening
to bottom of appliance = 24-1/2 IN.
MEASUREMENTS FROM TOP EDGE
OF THE APPLIANCE OPENING
4
5
6
16
9 10
18
MAX.
Measurement from top edge of opening
to bottom of appliance = 24-1/2 IN.
7
11
MEASUREMENT FROM
TOP EDGE OPENING
24
27
30
9
6
3
Measurement from top edge opening
to bottom of appliance = 24-1/2 IN.
MAX.
MEASUREMENTS FROM TOP EDGE
OF THE APPLIANCE OPENING
4
5
6
16
3
2
1
6
7
8
9
10 11
18
MAX.
Measurement from top edge of opening
to bottom of appliance = 24-1/2 IN.
NOTE: All measurements in inches.
WITHOUT
PASSIVE
HEAT
WITH
PASSIVE
HEAT
NOTE: All measurements in inches.
11/17/2023
11/17/2023