0016-2023-BCOM_BuildingComments_1 Subject: PlanCheck Page Index: 3 Author: nickt Color: File Name: 30.Special Inspection Agreement.453 E Hopkins.230412.pdf What work requires special inspection? 30.Special Inspection Agreement.453 E Hopkins.230412.pdf (1) Subject: PlanCheck Page Index: 2 Author: nickt Color: File Name: 90.Architectural Plans.453 E Hopkins.23.0327.pdf 2020 NEC 90.Architectural Plans.453 E Hopkins.23.0327.pdf (7) Subject: Employee work area Page Index: 4 Author: nickt Color: File Name: 90.Architectural Plans.453 E Hopkins.23.0327.pdf Employee work areas require an accessible route into and out of the space. Dimension entrance width, door maneuvering clearance, and provide a turnaround (could be a 'T' turnaround). 2015 IBC 1103.2.2 Subject: dining seating 5% Page Index: 4 Author: nickt Color: File Name: 90.Architectural Plans.453 E Hopkins.23.0327.pdf Indicate companion space. 2015 IBC 1108.2.3 and City policy. Subject: PlanCheck Page Index: 4 Author: nickt Color: File Name: 90.Architectural Plans.453 E Hopkins.23.0327.pdf Indicate adjacent occupancy groups (next to, above, and below). Project Address: ________ I have rea _________________ ______ Special Inspection Agency*** Signatu _________________ ______ Owner* Signatu 453 E. Ho CTL|Thompson, Inc. Ryan R. Barbone Lift One Lodge Aspen LLC What work requires special inspection? CODE ANALYSIS: NS 5, IMC 2015, IPC 2015, IECC 2015, NEC 2017 SIBILITY 17.1 2009 RUCTION TYPE EPARATED OCCUPANCIES (PER TABLE 508.4) EPARATION BETWEEN BUILDINGS (PER TABLE 602): FT, 1 HR (SOUTH, EAST, WEST WALLS) FT 0 HR ESISTANCE RATINGS (PER TABLE 601) (HRS): 2020 NEC B A 1 2 STORAGE 107 KITCHEN 106 RECEPTION 101 SALES 102 CORRIDOR 103 OFFICE 104 RESTROOM 105 1'-6 "2'-0"3'-6 " 5'-0" 3'-0 " 1'-6" 1'-6" 3'-0" 3'-0 " 36" CLEAR PATH FOR EGRESS DOORS TO REMAIN OPEN DURING BUSINESS HOURS 6'-0 " 6'-0 " DOORS TO REMAIN OPEN DURING BUSINESS HOURS 4'-0" DW RF SPD OV RF OCCUPANCY GROUP B (INCLUDINGACCESSORY STORAGE): 1,034 GSFOCCUPANT LOAD: 1 OCCUPANT/100 GSF11 TOTAL OCCUPANTS REMOTE POINT A: 51'-2"TRAVEL DISTANCE IS LESS THAN 100'-0"COMMON PATH OF TRAVEL MAXIMUM. 36" EXIT (SPACE HAS LESS THAN 50OCCUPANTS)32" CLEAR EGRESS WIDTH PROVIDED REMOTE POINT B: 62'-2"TRAVEL DISTANCE IS LESS THAN 100'-0" COMMON PATH OF TRAVEL MAXIMUM. EXITCL 3'-0 " 3'-0" R/F REFER TO ENLARGED PLANSFOR FIXTURE CLEAR FLOORAREAS & ACCESSIBILITY REFER TO ENLARGED PLANS FOR FIXTURE CLEAR FLOOR AREAS & ACCESSIBILITY EXIT NEW CLG MTD EXIT SIGN TO REPLACE EXISTING ADJACENT TENANT SPACE EXISTING EXTERIOR MASONRY WALL EXISTING EXTERIOR MASONRYWALL: 1-HR WALL REQUIRED PER TABLE 602: (EXTERIOR WALL IS < 5' FROM PROPERTYLINES) EXISTING DEMISING WALL: PER TABLE508.4, NO SEPARATION OF OCCUPANCIES REQUIRED FOR GROUP B EXISTING DEMISING WALL: PERTABLE 508.4, NO SEPARATION OFOCCUPANCIES REQUIRED FORGROUP B EXISTING COMPOSITE DECK FLOOR RETAILSPACE (GROUP M): PER TABLE 508.4 NOSEPARATION OF OCCUPANCIES REQUIRED. EXISTING TENANT SPACE IN2-STORY COMMERCIAL BUILDING ADJACENT TENANTSPACE EXISTING STOREFRONT:NO SEPARATION REQ. PER TABLE 602: (EXTERIOR WALL IS >30' FROM PROPERTY LINE) DW DOOR ACCESSIBLE DINING 1" 5'-6 5/8"3'-3" 3 1/ 4 " 0.88 SF AREA REDUCTION 0.46 SF AREA INCREASE 0.42 SF AREA REDUCTION FOOTPRINT OF EXISTINGBATHROOM © G u e r i n G l a s s A r c h i t e c t s , P . C . 2 0 2 2 SCALE: 1/4" = 1'-0" ACCESSIBILITY & EGRESS PLAN1 CHANGE OF USE UNDER THIS APPLICATION. NO CHANGE OF OCCUPANCY, OR EGRESS PROPOSED. SCALE: 1/2" = 1'-0" AREA CALC AT DEMISING WALL2 Employee work areasrequire an accessibleroute into and out ofthe space. Dimension entrance width, door maneuveringclearance, and providea turnaround (could bea 'T' turnaround). 2015 IBC 1103.2.2 KITCHEN 106 RECEPTION 101 1'-6" 3'- 0 " 6'- 0 " 6'- 0 " DW RF SPD OV RF 2" LESS THAN 100'-0" AVEL MAXIMUM. 36" EXIT (SPACE HAS LE OCCUPANTS) 32" CLEAR EGRESS WID EXITCL 3'- 0 3'-0" REFER TO ENLARGED PLANS FOR FIXTURE CLEAR FLOOR AREAS & ACCESSIBILITY EXIT NEW CLG MTD EXIT SIGN WALL: PER TABLE OF OCCUPANCIES RED FOR GROUP B EXISTING STOREFRONT: NO SEPARATION REQ. PER TABLE 602: (EXTERIOR WALL IS >30' FROM PROPERTY LINE) DW DOOR ACCESSIBLE DINING Indicate companion space. 2015 IBC 1108.2.3 and City policy. 36" EXIT (SPACE HAS LESS THAN 50 OCCUPANTS) 32" CLEAR EGRESS WIDTH PROVIDED NEW CLG MTD EXIT SIGN TO REPLACE EXISTING EXISTING COM SPACE (GROUP SEPARATION O XISTING STOREFRONT: O SEPARATION REQ. PER TABLE 602: XTERIOR WALL IS >30' FROM ROPERTY LINE) SCA AC 1 C Indicate adjacent occupancy groups (next to, above, and below). 07/24/2023 Subject: PlanCheck Page Index: 6 Author: nickt Color: File Name: 90.Architectural Plans.453 E Hopkins.23.0327.pdf New or replacement glazing U factors may not exceed: Fixed fenestration: U 0.29 Operable fenestration: U 0.37 Entrance doors: U 0.77 2015 IECC C402.4 Document the U-factors of the windows and glazed doors in accordance with City policy: The following are acceptable methods under the IECC to verify fenestration U-factors as part of the building thermal envelope: 1.NFRC certification, factory assembled: NFRC label applied to window assembly and verified at field inspection. 2.NFRC certification, site assembled: provide an NFRC CPD number or certificate of authorization from an NFRC authorized inspection agency prior to permit approval. To document the chain of custody, project specific NFRC labels must be affixed to the units or a project specific NFRC label certificate must be provided prior to field inspection. 3.Provide a simulation or test by an NFRC–accredited lab in accordance with NFRC-100 prior to permit approval. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the simulation or test is required prior to field inspection. 4.Provide a calculation using 2013 (or later) ASHRAE Fundamentals Handbook chapter 15, pg. 15.3: “U-Factor (Overall Coefficient of Heat Transfer)” prior to permit approval. Calculation is required to be in the standard NFRC window size of 47.2” x 47.2”. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the calculation is required prior to field inspection. 5.Use default values from Table 4 U-Factors for Various Fenestration Products in 2013 (or later) ASHRAE Fundamentals Handbook chapter 15, pg. 15.3 prior to permit approval. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the values is required prior to field inspection. 6.Use default values from IECC tables in chapter 3 of the residential and commercial sections. 16'- 6 " INSIDE FACE OF EXISTING STOREFRONT B A A41 D41 D41 D41 D41 A41 A41 A41 STORAGE 107 KITCHEN 106 RECEPTION 101 SALES 102 CORRIDOR 103 OFFICE 104 1 1'- 6 3 / 8 " 3'- 4 1 / 8 " A 102 A 104 A105A 103 A107 A 101 1'-1 5 / 8 " 1" T Y P . 1'- 1 5 / 8 " 15' - 4 3 / 8 " 9 1 / 2 " 3'-4 " 4'-1 1 " 11' - 1 0 1 / 8 " 4'-1 0 1 / 2 " 3" 4 5/8" 1'-2 " MILLWORK BASE TOREPLACE EXISTING, TYP. TAPE & PATCH SEAM BTWNNEW & EXISTING GYP, TYP A 106 1 A21 D41 D41 11 ' - 2 " 9 1 / 4 " 4 3 / 4 " 11' - 8 " 9'-1 0 " 2'-3"3'-4"3'-1" 1'-5"MIN.2'- 1 " 13 ' - 3 1 / 2 " 1'-1 1 / 2 " 1'-1 1 / 2 " 2'- 1 " R/F DW RF SPD OV RF A-502.00 1 MILLWORK CLOSET WALL WALL CABINETS & SHELVING EQUIPMENT CABINET 1'-5"MIN. NEW GYP TO REPLACEEXISTING NEW GYP TO REPLACE EXISTING NEW GYP TO REPLACEEXISTING NEW GYP TO REPLACE EXISTING NEW GYP TO REPLACEEXISTING NEW EXIST NEW MILLWORK PANELS ON 14" Z-CLIPS,REFER TO INTERIOR SERIES FOR DETAILS SCALE: 1/4" = 1'-0" FLOOR PLAN1 New or replacement glazing U factors may not exceed: Fixed fenestration: U 0.29Operable fenestration: U 0.37 Entrance doors: U 0.77 2015 IECC C402.4 Document the U-factors of the windows and glazed doors in accordance with City policy: The following are acceptable methods under the IECC to verify fenestration U-factors as part of the building thermal envelope: 1.NFRC certification, factory assembled: NFRC label applied to window assembly and verified at field inspection. 2.NFRC certification, site assembled: provide an NFRC CPD number or certificate ofauthorization from an NFRC authorized inspection agency prior to permit approval. To document the chain of custody, project specific NFRC labels must be affixed to the units or a project specific NFRC label certificate must be provided prior to field inspection.3.Provide a simulation or test by an NFRC–accredited lab in accordance with NFRC-100 prior to permit approval. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the simulation or test is required priorto field inspection. 4.Provide a calculation using 2013 (or later) ASHRAE Fundamentals Handbook chapter 15, pg. 15.3: “U-Factor (Overall Coefficient of Heat Transfer)” prior to permit approval.Calculation is required to be in the standard NFRC window size of 47.2” x 47.2”. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the calculation is required prior to field inspection.5.Use default values from Table 4 U-Factors for Various Fenestration Products in 2013 (or later) ASHRAE Fundamentals Handbook chapter 15, pg. 15.3 prior to permit approval. To document the chain of custody, an affidavit or other evidence from themanufacturer confirming compliance with the values is required prior to field inspection. 6.Use default values from IECC tables in chapter 3 of the residential and commercial sections. 07/24/2023 Subject: PlanCheck Page Index: 10 Author: nickt Color: File Name: 90.Architectural Plans.453 E Hopkins.23.0327.pdf Show door maneuvering clearance per ICC A117.1-2009 section 404.2.3.2. Lavatory may not encroach. Subject: PlanCheck Page Index: 13 Author: nickt Color: File Name: 90.Architectural Plans.453 E Hopkins.23.0327.pdf Controls for kitchen hood must be within accessible reach range. Subject: Lighting controls and comcheck Page Index: 5 Author: nickt Color: File Name: 90.Electrical Plans.453 E Hopkins.230120.pdf Specifically demonstrate compliance with the provisions of 2015 IECC C405, including: -Provide both interior and exterior lighting Comchecks; coordinated with lighting plans, schedule, and cutsheets. -Provide cutsheets for each fixture. Highlight the maximum fixture wattage (not the wattage of the lamp you intend to use but the maximum that the fixture is labeled for) and highlight the listing by a nationally recognized testing lab. -All fixtures must be specified; no "TBD." -Revise lighting plans to show all lighting control requirements including: -Occupant sensor controls -Time switch controls -Light-reduction controls -Daylight-responsive controls -Exterior lighting controls 90.Electrical Plans.453 E Hopkins.230120.pdf (1) Subject: PlanCheck Page Index: 6 Author: nickt Color: File Name: 90.Interiors Plans.453 E Hopkins.230120.pdf What is this? If this is a fireplace, provide installation instructions, include it on the fireplace registration form, and demonstrate compliance with the installation instructions. 90.Interiors Plans.453 E Hopkins.230120.pdf (1) RESTROOM 105 5'-0 5/8"1'-6"2'-3" 3'- 6 " 2'- 3 " 4'- 6 " 6" 1'-0"2'-0" 3'-0" 11 " 1'- 1 0 " lav wc A105 8'-9 5/8" PL-10 PL-10.1 PL-1 PL-10.2 AC-05 AC-04 AC-03 AC-01 CL CL 54"x60" CLEAR FLOOR SPACE FOR WALL MTD W 30"X48" CLEAR FLOOR SPACE FOR LAVATORY VERTICAL 18" GRAB BAR (NOT SCHEDULED) NOTE: REFER TO ID SERIES FOR PLUMBING AND ACCESSORIES SCHEDULES 1" 5'- 0 " 36 " 60" 36" T-SHAPED TURN AROUN SPACE 60"x54" CFS TURNING SPACE 30 " x 4 8 " SCALE: 1/2" = 1'-0" ENLARGED RESTROOM PLAN1 Show door maneuvering clearance per ICC A117.1-2009 section 404.2.3.2. Lavatory may not encroach. APPLIANCE #APPLIANCE TYPE MANUFACTURER CATALOG # A-1 REFRIGERATOR / FREEZER MIELE KFN 13923 DE EDT/CS A-2 DISHWASHER MIELE G 7591 SCVi AutoDos A-3 BEVERAGE FRIDGE SUMMIT AL55 A-4 SPEED OVEN MIELE DGC 7440 AM A-5 COOKTOP MIELE KM 6320 A-6 DOWNDRAFT HOOD MIELE DA 6881/DUU 2900-900 A-7 GARBAGE DISPOSAL INSINKERATOR 79329A-ISE Controls for kitchen hood must be within accessible reach range. KITCHEN 106 STORAGE 107 B A L1 (x3) L1A (x7) SC-LD-02SC-LD-02 L3 L4 RV1 RK1 -N1-1 RK1 - N1-2 7 8 RK1 - N1-4 N1-3 L1AE 3 L1AE 3 N2-1 SHADE CONTRO SUITE 2: 1 DAYLIGHT ZON © G u e r i n G l a s s A r c h i t e c t s , P . C . 2 0 2 2 Specifically demonstrate compliance with the provisions of 2015 IECC C405, including: -Provide both interior and exterior lighting Comchecks; coordinated with lighting plans, schedule, and cutsheets. -Provide cutsheets for each fixture. Highlight the maximum fixture wattage (not the wattage of the lamp you intend to use but the maximum that the fixture is labeled for) and highlight the listing by a nationally recognized testing lab. -All fixtures must be specified; no "TBD." -Revise lighting plans to show all lighting control requirements including: -Occupant sensor controls -Time switch controls -Light-reduction controls -Daylight-responsive controls -Exterior lighting controls 0'-0" FINISH FLOOR WD-01 WD-01 SF-01 SF-07 0'-0" FINISH FLOOR 5 SALES CENTEROFFICE NORTH ELEVATION SCALE: 1/2"=1'-0"6 SALES CENTEROFFICE EAST ELEVATION SCALE: 1/2"=1'-0" 3 SALES CENTERDINING LOUNGE EAST ELEVATION SCALE: 1/2"=1'-0" WD-01 WD-01 OPEN TO CORRIDORBEYOND 9'-0"CEILING HEIGHT B INTERIOR 3'-4" 3 SC-330 8'- 8 " WD-01 WD-01 4 SC-420 AC-03 5'- 6 " © G u e r i n G l a s s A r c h i t e c t s , P . C . 2 0 2 1 1 2 A B 1REVISION DATE SALES DINING EAST ELEVATION What is this? If this is a fireplace, provide installation instructions, include it on the fireplace registration form, and demonstrate compliance with the installation instructions. 07/24/2023 Subject: PlanCheck Page Index: 2 Author: nickt Color: File Name: 90.Mechanical and Plumbing Plans.453 E Hopkins.230120.pdf You have calculated the amount of outside air required but have not provided any outside air on the plans. Revise to provide outdoor air. 2015 IMC 403.2 90.Mechanical and Plumbing Plans.453 E Hopkins.230120.pdf (1) MECHANICAL EQUIPMENT WIRING AND CONNECTIONS ITEM FURNISHEDUNDER SET IN PLACEOR MTD. UNDER WIRED/CONNECTED UNDER 1.EQUIPMENT MOTORS AND THERMAL OVERLOADS, RESISTANCE HEATERS.MD MD ED 2.VFD'S, MOTOR CONTROLLERS; MAGNETIC STARTERS, REDUCED VOLTAGESTARTERS AND OVERLOAD RELAYS.MD ED(a)ED 3.DISCONNECT SWITCHES (FUSED OR NON-FUSED), HP RATED SWITCHES,THERMAL OVERLOAD SWITCHES AND FUSES AND MANUAL OPERATINGSWITCHES. ED(a)ED(a)ED 4. PUSHBUTTON STATIONS, PILOT LIGHTS, MULTI-SPEED SWITCHES, FLOATSWITCHES, THERMOSTATS, CONTROL RELAYS, TIMECLOCKS, CONTROLTRANSFORMERS, CONTROL PANELS, MOTOR VALVES, DAMPER ACTUATORS,SOLENOID VALVES, EP AND PE SWITCHES AND INTERLOCKS. MD MD MD(b) SCHEDULE NOTES: 1.ALL STARTERS FOR MECHANICAL EQUIPMENT SHALLBE FURNISHED UNDER THIS CONTRACT AND SET INPLACE AND WIRED BY EC. VFD'S NOT INCLUDED ASPART OF THE EQUIPMENT WIRING PACKAGE SHALLBE FURNISHED BY THE MC, AND SET IN PLACE ANDWIRED BY THE EC, U.N.O. 2.NOT ALL EQUIPMENT REQUIRED UNDER THISCONTRACT IS NECESSARILY SPECIFIED ON THE SCHEDULE SHEETS. PLAN & DIAGRAM NOTATIONSAND PROJECT MANUAL CONTAIN EQUIPMENTSPECIFICATIONS AS WELL. 3.NOT ALL CAPACITIES, CHARACTERISTICS, ANDCONSTRUCTION FEATURES REQUIRED ARENECESSARILY INDICATED IN THE EQUIPMENTSCHEDULES. RE: PLANS AND SPECIFICATIONS FORADDITIONAL REQ'MTS. 4.CAPACITIES, CHARACTERISTICS, ANDCONSTRUCTION FEATURES OF THE SCHEDULEDEQUIPMENT ARE HEREBY INCORPORATED INTO THEPROJECT REQUIREMENTS. EQUIVALENT PRODUCTSPERFORMANCE AND CONSTRUCTION FEATURESSHALL MEET OR EXCEED THAT OF THE SPECIFIED EQUIPMENT WHETHER SCHEDULED OR NOT. 5.NOT ALL EQUIPMENT AVAILABLE FROM LISTED "EQUIVALENT" MANUFACTURERS LISTED ISNECESSARILY EQUIVALENT TO THE BASIS OF DESIGNEQUIPMENT SPECIFIED. CONTRACTOR SHALL BESOLELY RESPONSIBLE FOR ANY COSTS, RESULTANTCHANGES TO OTHER DIVISIONS, AND SPATIALREQ'MTS FOR EQUIPMENT OTHER THAN SCHEDULED. 6.ALL MANUFACTURERS REPRESENTATIVES SHALLREAD AND UNDERSTAND THE CONTROL DIAGRAMSAND COORDINATE WITH TCC TO PROVIDE A FULLYFUNCTIONING SYSTEM AS DESCRIBED IN THECONTROL DIAGRAMS. GRILLE, REGISTER, DIFFUSER & LOUVER SCHEDULE MARK SERVICE PATTERN FINISH FRAME/ MOUNTING TYPE MANUFACTURER* & MODEL #ACCESSORIES REMARKS SUPPLY LINEAR BAR RE:INTERIORS BORDER TYPE 500 PRICE LBP16A REMOTE BALANCEDAMPER; XX ENDCONNECTION - RETURN LINEAR BAR RE:INTERIORS BORDER TYPE 500 PRICE LBP15A XX END CONNECTION - ALTERNATE MANUFACTURERS: * TITUS, KRUEGER, METALAIRE, RUSKIN, GREENHECK NOTES: [DESIGNER NOTE: ADD/EDIT AS NEEDED FOR PROJECT. ALL NOTES ARE NOT NECESSARILY USED ON THE PROJECT.] A:CONTRACTOR SHALL DETERMINE PROPER MARGIN STYLE TO MATCH CEILING/WALL CONSTRUCTION UNLESS OTHERWISE NOTED. REFER TOARCHITECTURAL PLAN FOR MORE INFORMATION.B:PROVIDE REMOTE ACCESS BALANCE DAMPER WHEN LOCATED OVER HARD CEILING. A B PLUMBING FIXTURE SCHEDULE SYMBOL TYPE A.D.A.FINISH DESCRIPTION MANUFACTURER* & MODEL # FAUCET TRIM MFR.* & MODEL #GPM/GPF ACCESSORIES REMARKS KITCHEN SINK ---RE: INTERIORS ---- BATHROOMSINK ---RE: INTERIORS --ASSE 1070THERMOSTATIC MIXINGVALVE - TOILET ---RE: INTERIORS ---- FIRE-RATED ICEMAKER BOX NO WHITE LEAD-FREE WITHHAMMER ARRESTERVALVE GUY GRAY FR-12 ----- MANUFACTURERS:FIXTURE: AMERICAN STANDARD, UNIVERSAL RUNDLE, FIAT STERN WILLIAMS FAUCET: SPEAKMAN, DELTA, AMERICAN STANDARD, CHICAGO DRAIN: SIOUX CHIEF, ZURN, JOSAM, WADE, JR SMITH GENERAL NOTES: A: B: P1 P2 P3 P4 SINGLE ZONE VENTILATION SCHEDULE ZONE 1 SUMMARY SPACE NAME SPACE TYPE Az [SQ.FT.] Rp [CFM/PERSON] Ra [CFM/SQ.FT.] PEOPLEDENSITY[#/1000SQ.SF.] Pz [PEOPLE] Vbz [CFM]Ez Vot [CFM] STORAGE GENERAL STORAGE 78 -0.12 --10 0.8 13 KITCHEN BREAK ROOM 265 5 0.06 25 7 51 0.8 64 RECEPTION LOBBY 251 7.5 0.06 30 5 54 0.8 68 DINING LOUNGE BREAKROOM 318 5 0.06 25 8 60 0.8 75 OFFICE OFFICE 88 5 0.06 5 5 31 0.8 39 RESTROOM TOILET ROOM 70 CFM / TOILET --- Vot 259 NOTES: [DESIGNER NOTE: ADD/EDIT AS NEEDED FOR PROJECT. ALL NOTES ARE NOT NECESSARILY USED ON THE PROJECT.] A:SCHEDULE IS BASED ON 20XX INTERNATIONAL MECHANICAL CODE. B: VENTILATION EQUATION VARIABLE DEFINITIONS:BREATHING ZONE OUTDOOR AIRFLOW, VbzZONE FLOOR AREA, AzZONE POPULATION, PzAREA OUTDOOR AIR RATE, RaPEOPLE OUTDOOR AIR RATE, RpZONE AIR DISTRIBUTION EFFECTIVENESS, Ez ZONE OUTDOOR AIRFLOW, VozSYSTEM OUTDOOR AIR INTAKE FLOW RATE, Vot VENTILATION EQUATIONS:Vbz = Rp * Pz + Ra * Az (EQUATION 4-1)Voz = Vbz / Ez (EQUATION 4-2)Vot = Voz (EQUATION 4-3 - SINGLE ZONE SYSTEMS) TATIC ALVE DIAGRAM LAVATORY CW AIR F L O W NO SCALE USE DUCT SEALANT ORGASKETED FITTING ON HIGHVELOCITY DUCT. CONICAL SPIN-IN FITTING W/MANUAL DAMPER, HANDLE, & LOCK NUT. FLEX DUCT. WORM DRIVE S.S. CLAMP. NOTE:DIAGRAM FOR LOW & HIGH VELOCITYDUCTWORK EXCEPT UPSTREAM OFVAV BOXES. OMIT DAMPER & FLEXDUCT UPSTREAM OF VAV BOXES. ROUND DUCT TAKE-OFF DIAGRAM FFUSER REMOTE BALANCE DAMPER DIAGRAM SIBLE BRANCH DUCT DAMPER INSULATED SUPPLYAIR PLENUM. 24" STANDARD CABLEOR AS REQUIRED. ROUNDDAMPER. TAKE-OFF ASREQUIRED. ADJUSTABLEMOUNTING CLAMP. DIFFUSER.ADJUSTS WITH 1/4"NUTDIRVER, SPECIFYOPTIONAL SCREWDRIVERTIP IF LESS THAN 3/8" NOTE:CEILING DIFFUSER SHOWN.FLOOR DIFFUSER SIMILAR. A BC LIFT ONE LODGE ASPEN, LLC605 W. MAIN STREET, SUITE 2ASPEN, CO 81611(970) 544 4196 SEAL IRONGATE, LLC10880 WILSHIRE BLVD SUITE 2222LOS ANGELES, CA 90024 DEVELOPERS PROJECT # SCALE ISSUE DESCRIPTION DATE ARCHITECT GUERIN GLASS ARCHITECTS, P.C.20 JAY STREET, 11TH FL., SUITE 1110BROOKLYN, NEW YORK 11201(212) 358-8380 HAYMAX CAPITAL, LLC605 W. MAIN STREET, SUITE 2ASPEN, CO 81611(970) 544-4196 BG BUILDINGWORKS, INC.251 LINDEN STREET, STE 200FORT COLLINS, CO 80524(970) 221 5691 MEP ENGINEER OWNER LIFT ONE LODGE SALES GALLERY 453 E. HOPKINS AVENUEASPEN, CO 81611 1803 MARTIN BRUDNIZKI DESIGN STUDIO227 W. 29TH STREET, 13TH FLOORNEW YORK, NY 10001(212) 929-2995 INTERIOR ARCHITECT 1 Permit Set 01.20.23 You have calculatedthe amount of outsideair required but have not provided anyoutside air on theplans. Revise to provide outdoor air.2015 IMC 403.2 07/24/2023 Page 1 of 1 20 Jay Street Suite 1110 Brooklyn, NY 11201 T: 212 358 8380 F: 212 358 8381 www.gueringlass.com July 7, 2023 453 E. Hopkins Ave – Architectural Responses to Building Dept. Comments Special Inspection Agreement - Page 3 · No special inspections anticipated other than final. Architectural Plans Page 2 · Current NEC corrected. Page 4 · Entrances width, door maneuvering clearances, and turnaround spaces added to drawings. Existing storage room width does not allow for a turnaround space but a door maneuvering clearance has been provided. · Plan updated to accommodate wheelchair and companion seating at dining. · Adjacent occupancy groups shown on plans, occupancy below space has been added to plans. Space is on top floor, no occupancy groups are above. Page 6 · New entry door has been omitted for existing to remain. No change proposed to existing storefront. Page 10 · Door maneuvering clearance added to plan, door and vanity revised so lavatory does not encroach. Page 13 · Switch for hood control added to plans at 48” aff. Appliance is also able to be operated wirelessly via phone app. Interiors Plans Page 6 · Storage cabinet in office has been omitted to provide door maneuvering clearance. 07/24/2023 2 5 1 L i n d e n S t r e e t , S u i t e 2 0 0 F o r t C o l l i n s , C O 8 0 5 2 4 P 9 7 0 . 2 2 1 . 5 6 9 1 www.bgbuildingworks.com July 10, 2023 Ms. Esther Cho Guerin Glass Architects, PC 20 Jay Street, Suite 1110 Brooklyn, NY 11201 RE: 453 E. Hopkins Ave (Lift One Sales Center) MEP Permit Review Comments BG Project #9649.03 Esther, BG Buildingworks, Inc. (BG) has provided responses to the mechanical, plumbing, and electrical permit review comments completed by the City of Aspen for the 453 E. Hopkins project in Aspen, CO. The following outlines the City’s comment followed by BG responses: 30.Special Inspection Agreement: What work requires special inspection? BG Response: None for MEP. 90.Architectural Plans: Controls for kitchen hood must be within accessible reach range. BG Response: Controls within reach have been added to the plans. 90.Electrical Plans: Specifically demonstrate compliance with the provisions of 2015 IECC C405, including: -Provide both interior and exterior lighting Comchecks; coordinated with lighting plans, schedule, and cutsheets. -Provide cutsheets for each fixture. Highlight the maximum fixture wattage (not the wattage of the lamp you intend to use but the maximum that the fixture is labeled for) and highlight the listing by a nationally recognized testing lab. -All fixtures must be specified; no "TBD." -Revise lighting plans to show all lighting control requirements including: -Occupant sensor controls -Time switch controls -Light-reduction controls -Daylight-responsive controls -Exterior lighting controls BG Response: Plan sheet E-101.00 illustrates occupant sensor controls, daylight responsive controls, daylight zones as well as time switch controls, see flag notes for additional details. See sheet E.300.00 for lighting control panel information including dimming zones on keypads, vacancy sensors, timeclock and photocell as well as their corresponding dimming information. Lighting Control Devices schedule note vacancy sensor information as well as a sequence of operations per IECC 2015. Light fixture schedules are also available on E.300.00 and have been updated to note custom listed socket wattage not lamp wattage. Custom portable table lamps are shown in the fixture schedule for reference only, portable fixtures are not included in Comcheck. Comcheck for interior is available on E-301.00, and has been updated to match the new lighting layout. There is no exterior scope of work on this project as it is a tenant finish, therefore no Exterior Comcheck. 07/24/2023 Lift One Sales Center July 10, 2023 Page - 2 – www.bgbuildingworks.com Cut sheets have been provided as a supplemental package and have been highlighted to note a maximum fixture wattage and national testing lab certification. All custom fixture specifications and testing certification to be submitted as a deferred submittal prior to inspection. Narrative of lighting changes: 1. L3 drapery pocket linear has been removed from Rooms 101, 102 and 106. 2. L3 under counter fixture in Office 104 has been removed. 3. L3 in Storage 107, length has been removed. 4. L11 has been added in Kitchen 106. 5. Decorative fixture type tags have been revised. 6. Sheet 300.00, the Distributed Networked System Lighting Control panel zoning and notes have been revised to accommodate the above changes. The Luminaire schedule has been updated to note revised fixture types. 7. Sheet 301.00, the Comcheck report has been updated to reflect the above changes. 90.Mechanical and Plumbing Plans: You have calculated the amount of outside air required but have not provided any outside air on the plans. Revise to provide outdoor air. 2015 IMC 403.2 BG Response: There is an existing OSA duct to the existing HVAC system; this was not clearly noted in the documents, however it is now noted to remain/be balanced to noted ventilation rates. Sincerely, Erin Pasold, PE Project Manager 07/24/2023