HomeMy WebLinkAboutFile Documents.634 W Hopkins Ave.0106-2021-BRES (24)C620STIO C-View See Through Indoor Outdoor
TECHNICAL SPECIFICATION
† Actual glass temperature will vary based on BTU, vent run configuration, fireplace
size, utilized media and panels, ambient temperature and other factors
GLASS
Glass Width: 72”
Glass Height: 20”
Glass Type: 5 mm or 6 mm thick tempered glass (standard)
8 mm tempered glass available (optional)
Laminated safety glass standard on units > 96” tall
No Glass: Open units are available
GLASS TEMPERATURE
COOL-Pack < 172°F †
Power COOL-Pack Up to a 60°F reduction†
TYPICAL INTAKE
Intake Location: Front, below glass
Intake Damper: Optional, tied into control system
TYPICAL EXHAUST
Power Vent: Integrally built into the system
GAS
Rating Input: Estimated 95,000 BTU/hr
Minimum Inlet Pressure: 5.5” w.c. Natural Gas / 11” w.c.
Propane
Gas System: ½” NPT, Hot Surface Ignition, Smart Valve
Concealed Burner with 8” ribbon flame or 16” high-low flame
CONSTRUCTION
Full stainless steel
ELECTRICAL
Standalone custom control panel mounted within 150’ of
fireplace, 208-240 VAC w Neutral, AMP rating depends on
actual spec
BURNER MEDIA
Glass media, driftwood logset, ceramic stones
OPTIONS
Uplighting, downlighting, lighting remote control, black
reflective glass, privacy glass
TESTING STANDARDS
ANSI Z21.50/ CSA 2.22-2016, ANSI Z21.97/ CSA 2.41-2017
GLASS DIMENSIONS CAN BE CUSTOMIZED
For further information visit:
www.montigo.com/commercial-fireplaces
Contact: quotes@montigo.com
This Montigo commercial fireplace and its associated components are part of a custom
engineered system.
This system is available with COOL-Pack or Power COOL-Pack cool-touch glass
technology, which is ideal for public use applications and residential common or
entertaining areas. All systems are power vented with multiple options available and are
tested and certified to current ANSI Standards with CSA International US and Canada.
All Montigo commercial fireplace systems are highly customizable. Please contact
Montigo to confirm if your installation requirements are within the parameters of these
standard specifications.
Finishing a Commercial Fireplace Facings
This guide applies to the following configurations:
STIO / ODD
C View STIO / ODD
C
C
FRAMING & FINISHING - PROUD
C
C
FRAMING & FINISHING - FLUSH
C
C
FRAMING & FINISHING - FLUSH
3¼”
Min.
3¼”
Min.Leave
area under
window
clear for air
intake: 12”
min
Leave
area under
window
clear for air
intake: 12”
min
Exterior
Finish
Interior Finish
OU
T
D
O
O
R
IN
D
O
O
R
Exterior FinishWaterproofing
Membrane Waterproofing
MembraneSteel Framing Steel Framing Steel Framing
Air Intake:
Must have 12”
clearance along
entire bottom
of window
Air Intake:
Must have 12”
clearance along
entire bottom
of window
Header
Must not rest on fireplace.
1” clearance from top of
fireplace throat.
Header
Must not rest on fireplace.
Leave 3/8” gap
all around window
frame to allow for
glass removal
Flue Gas
Exhaust
Flue Gas
Exhaust
Flue Gas
Exhaust
Do
n
o
t
f
i
n
i
s
h
t
h
e
f
r
a
m
e
o
r
f
r
o
n
t
fa
c
e
,
t
h
i
s
w
i
l
l
i
m
p
a
i
r
t
h
e
e
x
h
a
u
s
t
sy
s
t
e
m
a
n
d
g
l
a
s
s
r
e
m
o
v
a
l
Do
n
o
t
f
i
n
i
s
h
t
h
e
f
r
a
m
e
o
r
f
r
o
n
t
fa
c
e
,
t
h
i
s
w
i
l
l
i
m
p
a
i
r
t
h
e
e
x
h
a
u
s
t
sy
s
t
e
m
a
n
d
g
l
a
s
s
r
e
m
o
v
a
l
PROUD FINISH
This unit is designed to be
installed on an exterior wall,
or entirely outdoors. The air
intake channel at the base
of the exterior window must
not be obstructed.
SURFACE TEMPERATURES NOTE
Expect surface temperatures on body of fireplace to be approximately 120°-135°F on STIO and
ODD units. Temperature will vary with size of unit and ambient temperature.
FLUSH FINISHING
This unit is designed to be
installed on an exterior wall,
or entirely outdoors. The air
intake channel at the base
of the exterior window must
not be obstructed.
FLUE GAS EXHAUST
TEMPERATURES
Flue gas exhaust and vent
area are hot, temperatures of
200F-220F can be expected.
1” Gap 1” Gap 1” Gap 1” Gap
MANTELS AND SURROUNDS
Combustible mantels may safely be installed over the
fireplace provided that they do not project beyond the
shaded area shown.
There are no restrictions on Non-combustible mantels
providing they do not project beyond the facing material edge
and interfere with glass removal, and the weight of the mantel
is fully supported by the framing.
A NOTE ON MANTELS & SURROUNDS
National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government
demands for the wise use of energy, has prompted us to
manufacture many models of fireplaces which are hot, fuel
and energy efficient.
Please be aware; temperatures over the mantel will rise above
normal room temperature and walls above the fireplace may
be hot to touch.
We recommend careful consideration be given to the effects
of elevated mantel temperatures which may be in excess of
product design, for example: candles, plastic, or pictures. This
elevated heat can cause melting, deformation, discoloration
or premature failure of a TV and radio components.
123456789101112
1
1
5
5
18
11
15
2
2
6
6
19
12
16
3
3
9
7
7
8
9
10
11
12
13
20
13
17
4
4
10
8
14
Ve
r
t
i
c
a
l
H
e
i
g
h
t
(
I
n
.
)
Horizontal (In.)
Ensure the weight
of the mantel
and finishing will
not be resting on
the throat of the
fireplace
Combustible
construction
allowed in
shaded area
Finishing a Commercial Fireplace Mantels & Hearth
C View STIO / ODD
123456789101112
HEARTHS
Due to the air intake channel, no
hearths, combustible or otherwise, are
permitted within 12” of the frame edge.
Ai
r
i
n
t
a
k
e
Air exhaust
FLUE GAS
ELECTRICAL
INDOORSIDEOUTDOORSIDE
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
C620STIO
Front Intake
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES: FRACTIONAL + 1/8”
DATE
15/10/2020
w w w.monti g o .com
EXAMPLE CONFIGURATION
MONTIGO COMMERCIAL FIREPLACES ARE CUSTOM
BUILT FOR EACH PROJECT. THIS DRAWING IS FOR
REFERENCE ONLY.
FLUE AND AIR INTAKE SIZES ARE SUBJECT TO CHANGE
DEPENDING ON VENT RUN.
PRELIMINARY
DRAWING ONLY
Power COOL-Pack