HomeMy WebLinkAboutFile Documents.624 E Cooper Ave.0040-2024-BCOM (4)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
Red Hill Engineering, LLC
Glenwood Springs, CO 81601
RHE#: 24102001
October 20, 2024
Non-Load Bearing Partition Wall: Removal Approved
Project: ZigZag Restaurant Renovation
624 E Cooper Ave
Aspen, CO 81611
Attn: Pitkin County Building Department
530 E. Main St. Suite 205
Aspen, CO 81611
To whom it may concern,
Based on the structural evaluation conducted on-site by Red Hill Engineering (RHE) on
10/17/24, it has been confirmed that the roof structure, consisting of E-W oriented steel bar joists
bearing on the exterior walls and an intermediate N-S column-beam line, is fully independent of
the partition wall in question. The partition wall, which separates the kitchen from the dining area,
consists of drywall over metal studs and does not provide any structural support to the building.
As called for by current renovation plans, it is approved to remove two feet of this partition
wall floor-to-ceiling without any further considerations. The wall in question serves no
structural significance, and further removal beyond two feet is also approved as needed.
Please feel free to contact me for further clarification or if additional information is
required.
Sincerely,
_______________________________
Red Hill Engineering
Michael J. Dobbs, PE, Founder
Date: 10/20/2024
COMcheck Software Version COMcheckWeb
Interior Lighting Compliance Certificate
Project Title:
2021 IECC
Project Type:Alteration
Construction Site:
624 E Cooper Ave
Aspen, California 81611
Owner/Agent:
Romain Pavee
ZZ HOSP
624 E Cooper Avenue
Aspen, Colorado 81611
6469434994
romain@zz-hospitality.com
Designer/Contractor:
Jeffrey Halferty
Project Information
Energy Code:
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed
Watts
1-Common Space Types:Dining Area - Bar Lounge/Leisure 1800 0.86 1548
1548Total Allowed Watts =
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixture
Common Space Types: Dining Area - Bar Lounge/Leisure (1800 sq.ft.)
LED: Pendant: LED A Lamp 2.5W:1 13 60 780
LED: Chandelier: LED A Lamp 2.5W:8 1 240 240
LED: Inverted Chandelier: LED A Lamp 2.5W:8 1 240 240
LED: Recessed: LED A Lamp 2.5W:1 9 10 90
LED: Underbar: LED Undercabinet Unit 4W:1 4 25 100
LED: Banquettes: LED Undercabinet Unit 4W:1 3 25 75
1525Total Proposed Watts =
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES
Project Title:
Data filename:
10/30/24Report date:
82 ofPage
jeffrey halferty
10/30/24
APPLICATION ACCEPTED DATE: 2024-10-08 PERMIT NUMBER: 0040-2024-BCOM
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT COVERSHEET
PROPERTY INFORMATION
ADDRESS: 624 E COOPER AVE UNIT:
PARCEL ID: 273718225005 LEGAL DESCRIPTION: CITY AND TOWNSITE OF ASPEN
OWNER: HUNTER PLAZA ASSOC LLP
PERMIT CONTRACTOR:
DESCRIPTION OF WORK EPIC PERMIT.
INSTALL FLOORING ON TOP OF TILE FLOOR.
PLASTER AND PAINT ON TOP EXISTING DRYWALL.
DECORATIVE LIGHT FIXTURES.
SEATING
NEW COUNTERTOPS.
REMOVE OLD HOSTESS STAND TO MAKE ADA ACCESS BETTER
USE OF BUILDING Commercial FIRE SPRINKLER REQUIRED? Yes
CLASS OF WORK Commercial FIRE SPRINKLER TYPE NFPA 13
BUILDING TYPE (IRC) REQUIRED SPECIAL
INSPECTIONS
CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE
OCCUPANCY GROUP (IBC) A-2 WORK CHANGES BUILDING
FOOTPRINT? No
CODE EDITIONS 2021 IBC TOTAL SPA SQ.FT.
OTHER CODE EDITIONS 2021 TOTAL SNOWMELT SQ.FT.
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING? Yes
CITY OF ASPEN|2022 427 RIO GRANDE PL| ASPEN, CO
81611
11/04/2024
justinh
Signs require a separate permit.
No exterior work approved, except
for painting. No exterior lighting or
impacts to mechanical equipment
approved in scope of work.
sophiev
11/04/2024ZONING