Loading...
HomeMy WebLinkAboutFile Documents.624 E Cooper Ave.0040-2024-BCOM (4)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. Red Hill Engineering, LLC Glenwood Springs, CO 81601 RHE#: 24102001 October 20, 2024 Non-Load Bearing Partition Wall: Removal Approved Project: ZigZag Restaurant Renovation 624 E Cooper Ave Aspen, CO 81611 Attn: Pitkin County Building Department 530 E. Main St. Suite 205 Aspen, CO 81611 To whom it may concern, Based on the structural evaluation conducted on-site by Red Hill Engineering (RHE) on 10/17/24, it has been confirmed that the roof structure, consisting of E-W oriented steel bar joists bearing on the exterior walls and an intermediate N-S column-beam line, is fully independent of the partition wall in question. The partition wall, which separates the kitchen from the dining area, consists of drywall over metal studs and does not provide any structural support to the building. As called for by current renovation plans, it is approved to remove two feet of this partition wall floor-to-ceiling without any further considerations. The wall in question serves no structural significance, and further removal beyond two feet is also approved as needed. Please feel free to contact me for further clarification or if additional information is required. Sincerely, _______________________________ Red Hill Engineering Michael J. Dobbs, PE, Founder Date: 10/20/2024 COMcheck Software Version COMcheckWeb Interior Lighting Compliance Certificate Project Title: 2021 IECC Project Type:Alteration Construction Site: 624 E Cooper Ave Aspen, California 81611 Owner/Agent: Romain Pavee ZZ HOSP 624 E Cooper Avenue Aspen, Colorado 81611 6469434994 romain@zz-hospitality.com Designer/Contractor: Jeffrey Halferty Project Information Energy Code: Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts 1-Common Space Types:Dining Area - Bar Lounge/Leisure 1800 0.86 1548 1548Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixture Common Space Types: Dining Area - Bar Lounge/Leisure (1800 sq.ft.) LED: Pendant: LED A Lamp 2.5W:1 13 60 780 LED: Chandelier: LED A Lamp 2.5W:8 1 240 240 LED: Inverted Chandelier: LED A Lamp 2.5W:8 1 240 240 LED: Recessed: LED A Lamp 2.5W:1 9 10 90 LED: Underbar: LED Undercabinet Unit 4W:1 4 25 100 LED: Banquettes: LED Undercabinet Unit 4W:1 3 25 75 1525Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: 10/30/24Report date: 82 ofPage jeffrey halferty 10/30/24 APPLICATION ACCEPTED DATE: 2024-10-08 PERMIT NUMBER: 0040-2024-BCOM COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 624 E COOPER AVE UNIT: PARCEL ID: 273718225005 LEGAL DESCRIPTION: CITY AND TOWNSITE OF ASPEN OWNER: HUNTER PLAZA ASSOC LLP PERMIT CONTRACTOR: DESCRIPTION OF WORK EPIC PERMIT. INSTALL FLOORING ON TOP OF TILE FLOOR. PLASTER AND PAINT ON TOP EXISTING DRYWALL. DECORATIVE LIGHT FIXTURES. SEATING NEW COUNTERTOPS. REMOVE OLD HOSTESS STAND TO MAKE ADA ACCESS BETTER USE OF BUILDING Commercial FIRE SPRINKLER REQUIRED? Yes CLASS OF WORK Commercial FIRE SPRINKLER TYPE NFPA 13 BUILDING TYPE (IRC) REQUIRED SPECIAL INSPECTIONS CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE OCCUPANCY GROUP (IBC) A-2 WORK CHANGES BUILDING FOOTPRINT? No CODE EDITIONS 2021 IBC TOTAL SPA SQ.FT. OTHER CODE EDITIONS 2021 TOTAL SNOWMELT SQ.FT. HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? Yes CITY OF ASPEN|2022 427 RIO GRANDE PL| ASPEN, CO 81611 11/04/2024 justinh Signs require a separate permit. No exterior work approved, except for painting. No exterior lighting or impacts to mechanical equipment approved in scope of work. sophiev 11/04/2024ZONING