HomeMy WebLinkAboutFile Documents.800 S Monarch St.0097-2023-BCHO (5)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
SEE NOTES #1 PLANS
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
SPECIAL INSPECTION REQUIRED:
-Structural steel welding: Field & Shop
-High strength bolting
-Epoxy anchors
-Intumescent paint
-Spray applied fire resistive materials
-Permanent micropiles
Special inspection is required per 2015 IBC
section 1704. Inspector to verify that copy of
agreement for inspection program to be on
the job site prior to performing any
inspections. A copy of all Special Inspector
field reports to be on the job site for
inspectors' review if requested. Failure to
comply may result in denial of inspection.
READ THIS OR FAIL YOUR INSPECTION!
Furred & Dropped Ceilings, Soffits, and Walls
20015 IBC 803.13
This applies to the attachment of finishes or furring to any
assemblies that are required to be either fire-rated or
non-combustible and is separate from the fire-rated
assembly requirement.
Walls, Ceilings & Soffits: If furred 1 ¾ inches or
less, do one of the following:
4.Fill spaces with Class A material.
5.Fill spaces with inorganic or non-combustible material.
6.Fire block 8 feet in all directions.
Walls: If set out (furred) greater than 1 ¾ inches,
do one of the following:
4.Use a Class A finish material (such as drywall).
5.Use non-combustible framing.
6.Protect both sides with fire sprinklers.
Ceilings & Soffits: If dropped (furred) greater
than 1 ¾ inches:
Framing members, hangers, and other assembly
members must be non-combustible. You may not
use wood.
In Type III and V construction only, you may use fire
retardant treated wood or non-combustible framing.
RESIDENTIAL REFERENCES FROM 2015 IBC
CV/CS = crawl space ventilation sec. 1203.4. 18” x 24” access required
1209.1
EE = emergency escape required sec 1030
EU = enclosed usable space under stairs shall be 1-hr construction or stair
enclosure rating. No access from stair enclosure. ½” gypsum permitted for
stairs inside a single dwelling unit. 1011.7.3.
RV = roof and rafter ventilation required 1203.2
A = Attic Access 20” x 30” 1209.2
SA = smoke alarm (NFPA 72) required sec 907.2.11
CO = carbon monoxide detector req. per Aspen Municipal Code 8.15
SG = safety glazing required sec 2406
V = mechanical ventilation required sec 1203.1 & IMC 403 (bath fans and
whole house ventilation)
GR = guards, 42” min ht, 4” max opening. Guards within dwelling unit 36” min
ht sec 1015
HR = handrails 34”-38” ht sec 1014
DS = Draft stopping / fire blocking 718
RD = Roof drainage 1503.4
STC = Sound transmission class not less than 50 at dwelling separations, sec
1207
SI = Stairway Illumination 1205.4
PD = protect against decay, sec 2304.12
REFERENCES FROM 2015 IMC
DE = clothes dryer exhaust, sec 504. Makeup air req’d if over 200 CFM
AS = access and service space for maintenance req’d, sec 306
MA = make up air required if hood exhausts greater than 400 CFM, sec 505.2
ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes,
501.3.1
IT= intake openings 10’ from lot line & contaminant sources (vents, streets),
401.4
D = fasten and seal all ductwork per 603.9
REFERENCES FROM 2015 IFGC
DV = direct vent req’d, sec 303.3
CA = combustion air not taken from bedrooms, bathrooms or
storage sec 303.3
OD = outdoor appliances must be listed for outdoor use, sec 303.6
REFERENCES FROM 2015 IECC
F = new or replacement fenestration shall not exceed 0.28 U-factor, NFRC
label required, Ordinance 40, 2016
L = 75% of lamps in permanently installed lights must be high efficacy, sec
R404.1
SE = Continuous air barrier required; all exterior joints, cracks, and holes to be
caulked, gasketed, sealed, table R402.4.1.1
REFERENCES FROM 2014 NEC
EP = electric panel 'happy space' 30"x36"x78", not in storage, sec 110.26
FIRE RATED HATS REQUIRED
Where floor/ceiling or roof/ceiling
assemblies are required to have a
fire-resistive rating, recessed fixtures shall
be installed such that the required fire
resistance will not be reduced (IBC 714.4.2)
75% of lamps in permanently
installed light fixtures shall be
high efficacy - IECC R404.1
SEE NOTES #1 PLANS
11/06/2023
jimp
APPLICATION ACCEPTED DATE: 2023-10-09 PERMIT NUMBER: 0097-2023-BCHO
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT COVERSHEET
PROPERTY INFORMATION
ADDRESS: 800 S MONARCH ST 07 UNIT:
PARCEL ID: 273513128012 LEGAL DESCRIPTION: MOUNTAIN QUEEN
OWNER: S C JOHNSON AND SON INC
PERMIT CONTRACTOR:
DESCRIPTION OF WORK changes to an existing building beyond the origianl permit to include: elimination of motorized cover on pool
and spa, demolition of existing concrete slab in fitness room, revision of routing of mech, elect and plumbing
due to unforeseen conditions of existing structure, new pool mechanical room carved out of existing mech
level, new unit heater layout in garage, new/revised details and finishes, new mechanical and electrical layouts
in fitness
USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? No
CLASS OF WORK Residential FIRE SPRINKLER TYPE
BUILDING TYPE (IRC) REQUIRED SPECIAL
INSPECTIONS
CONSTRUCTION TYPE ENERGY CODE COMPLIANCE Prescriptive Table
OCCUPANCY GROUP (IBC) B WORK CHANGES BUILDING
FOOTPRINT? No
CODE EDITIONS TOTAL SPA SQ.FT.
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT.
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING? No
1
CEILING RADIATION DAMPERS REQUIRED
Ducts and air transfer openings penetrating the ceiling of a
fire rated ceiling assembly must be protected with a listed
ceiling radiation damper. This includes bathroom exhaust
fans. (IBC 717.6.2)