HomeMy WebLinkAboutFile Documents.1280 Red Butte Dr.0148-2023-BRES (13)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
luisp
12/07/2023ZONING
LEVEL 4 ALTERATION REQUIREMENTS
Your approved scope has triggered a Level 4 Alteration and the following are required:
- Exposed wall cavities must be insulated to the cavity portion of IECC prescriptive alteration table
R402.1. (IECC R503.1.3 item 2)
- 2x6: R-20
- 2x4: R-13
- Blower door test required at final. If <5 ACH50 whole dwelling ventilation required (may be
supply only, exhaust only including a controlled bath fan, or combo including but not limited to
ERV or HRV) (IECC R503.1.1.5)
- Sign up for energy reporting (BIQ benchmarking - IECC R503.1.6)
Ordinance 1, 2023
Note the skylight materials,
including the thickness of the
interlayer. 2021 IBC 2405.2
requires a minimum 0.03"
polyvinylbutryal interlayer, unless
the skylight is 16sqft or less and is
less than 12' above the interior
floor, then it may have a 0.015" pvb
interlayer. Provide a detail of the
curb (minimum height 4" for slopes
less than 3:12). Provide the
U-factor of the skylight assembly-
maximum:
0.44 for new construction
0.50 for existing construction
if using the prescriptive path in
2021 IECC 402.1.3.
To verify fenestration U-factors, the following is
REQUIRED PRIOR TO GLAZING INSPECTION:
Factory built windows:
An NFRC label must be affixed to the window assembly and
verified at field inspection.
Site built windows:
CPD numbers have been approved. Project specific NFRC
labels must be affixed to the units or a project specific NFRC
label certificate must be provided prior to field inspection.
Site built windows:
A certificate of authorization from an NFRC authorized inspection
agency has been received and approved. Project specific NFRC
labels must be affixed to the units or a project specific NFRC
label certificate must be provided prior to field inspection.
Site built windows:
ASHRAE calculations were approved. To document the chain of
custody, an affidavit or other evidence from the manufacturer
confirming compliance with the calculations are required
prior to field inspection.
Site built windows:
A simulation by an NFRC–accredited lab in accordance with
NFRC-100 has been approved. Verification labels must be
affixed to the window units by an accredited independent
inspection agency or a certificate, affidavit or other evidence
from the manufacturer confirming compliance with the
NFRC-100 simulation or testing must be provided for
approval prior to inspection.
100% of lamps in
permanently installed light
fixtures must be high efficacy
- IECC R404.1
03/27/2024
linzhid
0148-2023-BRES
1280 RBD LLC
1280 RED BUTTE DR
273501316001
NOTE: a final air clearance
asbestos
abatement report prior to
permit issuance