Loading...
HomeMy WebLinkAboutFile Documents.605 Cemetery Ln.0052-2024-BROF (7)ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2023 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 14 www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® ICC-ES Evaluation Report Reissued October 2022 ESR-1463 Revised May 2023 This report is subject to renewal October 2023. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC SYSTEMS, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE-PLY ROOFING MEMBRANES ADDITIONAL LISTEES: MULE-HIDE PRODUCTS COMPANY, INC. VERSICO, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC WEATHERBOND, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC ROOFING PRODUCTS INTERNATIONAL, INC. 1.0 EVALUATION SCOPE Compliance with the following codes: 2021, 2018, 2015, 2012 and 2009 International Building Code® (IBC)  2021, 2018, 2015, 2012 and 2009 International Residential Code® (IRC) 2013 Abu Dhabi International Building Code (ADIBC)† †The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. For evaluation for compliance with codes adopted by the Los Angeles Department of Building and Safety (LADBS), see ESR-1463 LABC and LARC Supplement. Properties evaluated: Weather resistance Roof covering fire classification Wind uplift resistance Impact resistance 2.0 USES Carlisle ethylene propylene diene monomer (EPDM), polyvinyl chloride (PVC) and thermoplastic polyolefin (TPO) single-ply roofing membranes are used as roof coverings in adhered and mechanically fastened membrane roofing systems. 3.0 DESCRIPTION 3.1 General: The EPDM, PVC and TPO Membrane Roofing Systems described in this report consist of single-ply roofing membranes, insulation where used, barrier board or slip sheet where used, flashing, mechanical fasteners and adhesives that are installed on a combustible or noncombustible deck. See Table 1 for Carlisle product trade names and corresponding product names for Mule-Hide Products Company, Inc., WeatherBond, Versico, and Roofing Products International, Inc., the additional listees. 3.2 EPDM Membranes: 3.2.1 Sure-Seal EPDM Membrane: Sure-Seal EPDM Membrane is a black, nonreinforced EPDM membrane, 45 mils thick [0.045 inch (1.14 mm)]. 3.2.2 Sure-Seal FR EPDM Membrane: Sure-Seal FR EPDM Membrane is a black, nonreinforced EPDM membrane with fire retardants. Available thicknesses range from 45 mils (0.045 inch [1.14 mm]) to 90 mils (0.090 inch [2.29 mm]). 3.2.3 Sure-White EPDM Membrane: Sure-White EPDM Membrane is a white, nonreinforced EPDM membrane. Available in thicknesses of 60 mils [0.060 inch (1.52 mm)] and 90 mils [0.090 inch (2.29 mm)]. 3.2.4 Sure-White Reinforced EPDM Membrane: Sure- White Reinforced EPDM Membrane is a white, reinforced EPDM membrane. Available in a thickness of 60 mils [0.60 inch (1.52 mm). 3.2.5 Sure-Tough EPDM Membrane: Sure-Tough EPDM Membrane is a black, reinforced membrane consisting of a polyester reinforcement encapsulated between two EPDM membrane plies. Available in thicknesses ranging from 45 mils [0.045 inch (1.14 mm)] to 75 mils [0.075 inch (1.90 mm)]. 3.2.6 Sure-Seal FleeceBACK EPDM Membrane: Sure- Seal FleeceBACK EPDM Membrane is a 45-mil to 90-mil [0.045 inch to 0.090 inch (1.14 mm to 2.29 mm)] non- ESR-1463 | Most Widely Accepted and Trusted Page 2 of 14 reinforced EPDM bonded to a polyester fleece. Available product thicknesses range from 100 mils [0.100 inch (2.55 mm)] to 145 mils [0.145 inch (3.68 mm)]. 3.2.7 Sure-White FleeceBACK EPDM Membrane: Sure- White FleeceBACK EPDM Membrane is a 45-, 60- or 90-mil [0.045, 0.060 or 0.090 inch (1.14, 1.52 or 2.29 mm)] nonreinforced white EPDM bonded to a polyester fleece. Available product thicknesses are 100, 115 and 145 mils [0.100, 0.115 or 0.145 inch (2.54, 2.92 or 3.68 mm)]. 3.2.8 Sure-Seal AFX EPDM Membrane: Sure-Seal AFX EPDM Membrane is a 45-mil [0.045 inch (1.14 mm) or 60-mil [0.060 inch (1.52 mm)] non-reinforced EPDM bonded to a polyester fleece. Available thicknesses are 90 mils [0.090 inch (2.29 mm)] and 105 mils [0.105 inch (2.67 mm)]. 3.3 PVC Membranes: 3.3.1 Sure-Flex PVC Membrane: Sure-Flex PVC Membrane is a heat-weldable PVC thermoplastic membrane consisting of a weft-inserted polyester fabric that is encapsulated by PVC based top and bottom plies. Available thicknesses range from 50 mils [0.050 inch (1.27 mm)] to 80 mils [0.080 inch (203 mm)]. 3.3.2 Sure-Flex KEE HP Membrane: Sure-Flex KEE HP Membrane is a heat-weldable thermoplastic membrane that consists of a polyester fabric that is encapsulated by KEE HP based top and bottom plies. Available thicknesses range from 50 mils [0.50 inch (1.27 mm)] to 80 mils [0.80 inch (2.03 mm)]. 3.3.3 Sure-Flex PVC FRS Membrane: Sure-Flex PVC FRS Membrane is a heat-weldable thermoplastic membrane that consists of a fiberglass reinforcement encapsulated with PVC based top and bottom plies. Available thicknesses range from 60 mils [0.60 inch (1.52 mm)] to 80 mils [0.80 inch (2.03 mm)]. 3.3.4 Sure-Flex PVC FleeceBACK Membrane: Sure-Flex PVC FleeceBACK Membrane consists of polyester reinforcing scrim and polyester fleece backing. Available thicknesses range from 115 mils [0.115 inch (2.92 mm)] to 135 mils [0.135 inch (3.43 mm)]. 3.3.5 Sure-Flex KEE HP FleeceBACK Membrane: Sure- Flex KEE HP FleeceBACK Membrane consists of a polyester reinforcing scrim, polyester fleece backing, and DuPont® Elvaloy® KEE HP copolymer. Available thicknesses range from 105 mils [0.105 inch (2.67 mm)] to 135 mils [0.135 inch (3.43 mm)]. 3.3.6 Sure-Flex PVC FRS FleeceBACK Membrane: Sure-Flex PVC FRS FleeceBACK Membrane consists of a high-strength fiberglass scrim and polyester fleece backing. Available thicknesses range from 115 mils [0.115 inch (2.92 mm)] to 135 mils [0.135 inch (3.43 mm)]. 3.3.7 Sure-Flex KEE HP FRS FleeceBACK Membrane: Sure-Flex KEE HP FRS FleeceBACK Membrane consists of a fiberglass reinforcing scrim, polyester fleece backing, and DuPont® Elvaloy® KEE HP copolymer. Available thicknesses range from 105 mils [0.105 inch (2.67 mm)] to 135 mils [0.135 inch (3.43 mm)]. 3.4 TPO Membranes: 3.4.1 Sure-Weld TPO Membrane: Sure-Weld TPO Membrane consists of a polyester reinforcement encapsulated between two plies of TPO. The membrane is available in white, gray, tan and custom colors. Available thicknesses range from 45 mils [0.045 inch (1.14 mm)] to 60 mils [0.060 inch (1.52 mm)]. 3.4.2 Sure-Weld EXTRA TPO Membrane: Sure-Weld EXTRA TPO Membrane is a thicker version of the Sure- Weld TPO Membrane specified in Section 3.4.1 for increased strength and weatherability. The membrane is available in white, gray, tan and custom colors. Available in a thickness of 80 mils (0.080 inch [2.03 mm]). 3.4.3 Sure-Weld HS TPO Membrane: Sure-Weld HS TPO Membrane is the Sure-Weld membrane formulated with an additional flame retardant for fire resistance at higher slopes. The membrane is available in white, gray, tan and custom colors. Available thicknesses are 45 mils (0.045 inch [1.14 mm]) and 60 mils (0.060 inch [1.52 mm]). 3.4.4 Sure-Weld SAT-TPO Membrane: Sure-Weld SAT- TPO Membrane is a self-adhered version of the Sure-Weld HS TPO membrane with adhesive. 3.4.5 Sure-Weld FleeceBACK TPO Membrane: Sure- Weld FleeceBACK TPO Membrane is the Sure-Weld HS TPO Membrane, 45 mils [0.045 inch (1.14 mm)], 60 mils [0.60 inch (1.52 mm)] and 80 mils [0.60 inch (2.03 mm)] thick, with a laminated polyester fleece backing. Available thicknesses are 100 mils [0.100 inch (2.54 mm)], 115 mils [0.115 inch (2.92 mm)] and 135 mils [0.135 inch (3.43 mm)]. 3.4.6 Sure-Weld AFX TPO Membrane: Sure-Weld AFX TPO Membrane is the Sure-Weld HS TPO Membrane with a laminated polyester fleece backing. Available thicknesses range from 120 mils [0.120 inch (3.05 mm)] to 155 mils [0.155 inch (3.94 mm)]. 3.4.7 Spectro-Weld TPO Membrane: Spectro-Weld TPO Membrane is the Sure-Weld membrane, described in Section 3.4.1, formulated with a brighter white color. Available thicknesses are 60 mils [0.060 inch (1.52 mm)] and 80 mils [0.080 inch (2.03 mm)]. 3.4.8 Spectro-Weld FleeceBACK TPO Membrane: Spectro-Weld FleeceBACK TPO Membrane is the Spectro- Weld membrane with a laminated 5.5-ounce-per-square- yard (0.18 kg/m2) polyester fleece backing. Available in a thickness of 115 mils [0.115 inch (2.92 mm)]. 3.5 Insulation: See Tables 2 through 5 for insulations for use with specific roofing systems. Insulation must comply with IBC Section 1508.2 or IRC Section R906.2, as applicable. Foam plastic insulation, where used, must have a flame-spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E84 or UL 723. 3.6 Barrier Board: Barrier board, where used, must be either minimum 1/4-inch-thick (6.4 mm) Georgia-Pacific Gypsum LLC “DensDeck® Roofboard” or “DensDeck Prime® Roofboard,” minimum 1/4-inch-thick (6.4 mm) Owens Corning “StrataGuard,” minimum 1/4-inch-thick (6.4 mm) USG Corporation “SECUROCK® Gypsum-Fiber Roof Board” or “SECUROCK® Glass-Mat Roof Board,” or minimum 1/2-inch-thick (12.7 mm) gypsum board. Barrier board must be UL-classified for roofing applications or UL-classified gypsum board. 3.7 Slip Sheet: The slip sheet, where used, must include Carlisle “FR Base Sheet 1S or 2S,” GAF “VersaShield® Fire-Resistant Roof Deck Protection (ESR-2053)” or Atlas “FR 10 or FR 50.” Slip sheets must be UL-classified for roofing applications. 3.8 Flashing: Flashing must be provided in accordance with IBC Section 1503.2 or IRC Section R903.2, as applicable. Where flashing is of metal, the metal must be corrosion-resistant, minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized steel. ESR-1463 | Most Widely Accepted and Trusted Page 3 of 14 3.9 Fasteners: Fasteners, used to mechanically attach insulation and membranes to the roof deck, must be corrosion-resistant, and must be Carlisle fasteners, plates or fastening bars, unless otherwise noted in this report. Refer to Table 4 and 5 for spacing of fasteners. 3.9.1 HP Fastener: This is an epoxy-coated steel screw used in combination with Carlisle’s fastening plates or bars to mechanically attach roofing insulation and membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.2 InsulFast Insulation Fastener: This is an epoxy- coated steel screw used in combination with Carlisle’s insulation plates to mechanically attach roofing insulation to steel or wood substrates. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), or into the wood deck a minimum of 1 inch (25.4 mm). 3.9.3 HP Purlin Fastener: This is an epoxy-coated steel screw used in combination with Carlisle’s fastening plates or bars to mechanically attach roofing insulation and membranes to structural steel members. Fastener length must be selected to penetrate through the steel member a minimum of 3/4 inch (19.1 mm.) 3.9.4 HD 14-10 Fastener: This is a heavy-duty, epoxy- coated steel screw used in combination with Carlisle’s fastening plates or bars to mechanically attach roofing insulation and membranes to concrete roof deck. Fastener length must be selected to penetrate into the concrete deck a minimum of 1 inch (25.4 mm). 3.9.5 CD-10 Fastener: The CD-10 is an epoxy-coated, hammer-driven, nonthreaded fastener specifically designed to be used with insulation and seam fastening plates to secure membrane and insulation to structural concrete. Fastener length must be selected to penetrate into the concrete deck a minimum of 1 inch (25.4 mm). 3.9.6 Lite-Deck Fastener: The Lite-Deck Fastener is used in conjunction with a specially designed 3-inch (76.2 mm) Lite-Deck Metal Plate for insulation attachment to gypsum, cementitious wood fiber (Tectum [ESR-1112]), and lightweight concrete decks. Fastener length must be selected to penetrate into the deck a minimum of 2 inches (50.8 mm). 3.9.7 GypTec Fastener: The GypTec Fastener is a glass- filled nylon auger fastener designed for securing mechanically attached membranes and insulation to gypsum and cementitious wood fiber (Tectum [ESR-1112]) decks. Fastener length must be selected to penetrate into the deck a minimum of 1.5 inches (38.1 mm). 3.9.8 HP Polymer Seam Plate: This is a 2-inch-diameter (50 mm) polymer plate designed to be used with HP and HD 14-10 fasteners to mechanically attach roofing membranes to the roof deck. 3.9.9 Sure-Tite Fastener and ST Fastening Bar: This is a heavy-duty, epoxy-coated steel screw and bar used to secure reinforced EPDM membranes to steel or wood deck. The bar is 1-inch-wide-by-0.040-inch-thick-by-10-foot-long (25.4 mm by 1.1 mm by 3.1 m) galvalume-coated steel with pre-punched holes 6 inches (150 mm) on center. 3.9.10 HP-X Fastener: This is an epoxy-coated carbon steel screw used in combination with the Piranha Fastening Plate to mechanically attach TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.11 Piranha Fastening Plate: This is a 23/8-inch- diameter galvalume-coated steel plate designed to be used with HP-X fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.12 HP-XTRA Fastener: This is an epoxy-coated carbon steel screw used in combination with the Piranha XTRA Fastening Plate to mechanically attach PVC and TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm) and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.13 Piranha XTRA Fastening Plate: This is a 23/8-inch- diameter galvalume-coated steel plate designed to be used with HP-XTRA fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.14 PVC Oval Barbed Plate: This is a 11/2-inch-by- 23/4-inch (35 mm by 69.85 mm) Oval Barbed Plate designed to be used with HP-X Fasteners to mechanically attach PVC membranes to the roof deck. 3.9.15 OMG Roofing Products RhinoBond Plate: The RhinoBond Plate is a 3-inch-diameter (76.2 mm), 0.028-inch-thick (0.7 mm) galvalume-coated steel plate, coated with a proprietary adhesive and used with the HP-X fastener to mechanically attach PVC and TPO membranes to the roof deck. The adhesive bonds the plate to the underside of the membrane. 3.10 Carlisle SynTec Adhesives: See Tables 2 and 5 for adhered roofing systems. 3.10.1 90-8-30A Bonding Adhesive: 90-8-30A Bonding Adhesive is a high-strength, solvent-based contact adhesive used to adhere EPDM membranes to the insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m2/L) when applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers and has a shelf life of one year. 3.10.2 Aqua Base 120 Bonding Adhesive: Aqua Base 120 Bonding Adhesive is a high-strength, water-based contact adhesive used to adhere EPDM and TPO membranes to the insulation or substrate. It has a coverage rate of approximately 120 square feet per gallon (3 m2/L) when applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers and has a shelf life of one year. 3.10.3 Low-VOC PVC Bonding Adhesives: Low VOC PVC Bonding Adhesives is high-strength, solvent-based contact adhesives used to adhere PVC membranes to an insulation or substrate. They have a coverage rate of approximately 60 square feet per gallon (1.5 m2/L) when applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.4 Sure-Weld TPO Bonding Adhesive: Sure-Weld TPO Bonding Adhesive is a high-strength, solvent-based contact adhesive used to adhere TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m2/L) when applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding Adhesive is a high-strength, solvent-based contact ESR-1463 | Most Widely Accepted and Trusted Page 4 of 14 adhesive used to adhere EPDM and TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m2/ L) when applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.6 HydroBond Water-Based Bonding Adhesive: HydroBond Water-Based Bonding Adhesive is a water- based, wet lay-in, one-sided adhesive to be used to adhere Sure-Flex PVC, Sure-Flex PVC FRS and FleeceBACK membranes to an insulation or substrate. It has a coverage rate of 100 square feet per gallon (2.5 m2/L). The adhesive is supplied in 5-gallon (918.9 L) containers with a shelf life of one year. 3.10.7 Low VOC Bonding Adhesive 1168: Low VOC Bonding Adhesive 1168 is high-strength, solvent-based contact adhesive used to adhere EPDM and TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.58 m2/L) when applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.8 Cold Applied Adhesive: Cold Applied Adhesive is a solvent-free, asphalt-modified polyether adhesive. This adhesive can be used with all Sure-Seal or Sure-Weld AFX membranes as a one-sided, wet lay-in adhesive. It has a coverage rate of 67 square feet per gallon (1.6 m2/L). The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.9 Flexible FAST Adhesives: Flexible FAST Adhesives are two-component polyurethane adhesives used to adhere FleeceBACK membranes and insulations to various substrates. The adhesives have a coverage rate of approximately 100 square feet per gallon (2.5 m2/L). The adhesives are supplied in 5-gallon (18.9 L) jugs, 15-gallon (56.7 L) and 50-gallon (189 L) drums, box sets, cartridge tubes, dual tanks, and/or cylinders, and have a shelf life of one year. 3.10.10 OlyBond 500 Adhesive: OMG Roofing Products OlyBond 500 Spot Shot and OlyBond 500 BA are two-component polyurethane adhesives used to adhere insulations to various substrates. The adhesives have a coverage rate of approximately 100 square feet per gallon (2.5 m2/L). The adhesives are supplied in cartridge tubes and box sets, and have a shelf life of one year. 3.10.11 EPDM X-23 Low-VOC Bonding Adhesive: EPDM X-23 Low-VOC Bonding Adhesive is a high strength, solvent-based contact adhesive used to adhere EPDM membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m2/L) when applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.12 CAV-GRIP III Low-VOC Adhesive/Primer: CAV- GRIP III Low-VOC Adhesive/Primer is a contact adhesive used to adhere EPDM and TPO membranes to various substrates. It has a coverage rate of 1000 ft2 per cylinder when applied to the finished surface area. The adhesive is supplied in No. 40 cylinders with a shelf life of one year (unopened). 3.11 Impact Resistance: The EPDM, PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in 2021 IBC Section 1504.8 [2018, 2015, 2012 and 2009 IBC Section 1504.7], based on testing in accordance with Section 4.6 of FM 4470. 4.0 INSTALLATION 4.1 General: Installation of the EPDM, PVC, and TPO roofing membranes described in this report must comply with the applicable code, the manufacturer’s published installation instructions and this report. The manufacturer’s published installation instructions must be available at all times on the jobsite during installation. The substrate to which the membrane is to be applied must be clean, dry, and free of frost, loose fasteners, and other protrusions or contaminates that will interfere with the adhesion or attachment of the membrane or that will puncture the membrane. All materials must be protected against contact with incompatible materials. Where gypsum board is used as barrier board in the roofing assembly, weather protection must be provided to prevent damage to the gypsum board prior to application of the roofing membrane. The slope of the roof on which the single-ply membranes are installed must not be more than the maximum slope indicated for the particular assembly as listed in Tables 2 and 3. Penetrations and terminations of the roof covering must be flashed and made weather tight in accordance with the requirements of the membrane manufacturer and the applicable code. 4.2 Fire Classification: 4.2.1 New Construction: The adhered and mechanically fastened EPDM, PVC, and TPO single-ply membrane roofing systems, when installed in accordance with this report, are Class A, B or C roof covering systems in accordance with ASTM E108 or UL 790, as noted in Tables 2 and 3. 4.2.2 Reroofing: The existing deck must be inspected to verify that the structure to be reroofed is structurally sound and adequate to support and secure the roofing membrane. Prior to installation of new roof coverings, inspection by and written approval from the code official having jurisdiction must be required. Class A, B or C roof covering systems may be installed over existing classified roof covering systems under the following conditions without additional roof classification tests, provided the resulting classification is the lower of the new or existing roofing classification: New uninsulated systems installed only over existing uninsulated assemblies.  New insulated systems installed over existing uninsulated systems only. 4.3 Wind Resistance: 4.3.1 New Construction: The allowable wind uplift pressures for the EPDM, PVC, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. Metal edge securement systems must be listed in accordance with the 2017 edition of ANSI/SPRI/FM4435 ES-1 and designed and installed for wind loads in accordance with 2021 IBC Section 1504.6 [2018, 2015, 2012 and 2009 IBC Section 1504.5] and IBC Chapter 16. 4.3.2 Reroofing: Mechanically anchored systems may be accepted based on the adequacy of anchors penetrating through existing roof coverings into structural substrates. Since the composition and/or condition of any particular existing underlying material may vary widely, reroofing with adhered systems is outside the scope of this report. ESR-1463 | Most Widely Accepted and Trusted Page 5 of 14 5.0 CONDITIONS OF USE The single-ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with the applicable code, the manufacturer’s published installation instructions and this report. The instructions within this report must govern if there are any conflicts between the manufacturer’s installation instructions and this report. 5.2 The adhered and mechanically fastened single-ply membrane roofing systems must be installed by professional roofing contractors who are trained and approved by the manufacturer. 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with IBC Section 2603.4.1.5 or IRC Section R316.4, as applicable. 5.4 Foam plastic insulation, where used, must bear the label of an approved agency indicating that the foam plastic has a flame-spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E84 or UL 723, subject to the approval of the code official. 5.5 Design wind uplift pressure on any roof area, including edge and corner zones, must not exceed the allowable wind uplift pressure for the system installed in that particular area. Refer to allowable wind uplift pressures for systems as listed in Tables 4 and 5. 5.6 The allowable wind uplift pressures listed in Tables 4 and 5 are for the roof covering system only. The deck and framing to which the system is attached must be designed for the applicable components and cladding wind loads in accordance with the applicable code. 5.7 When application is over existing roofs, documentation of the wind-uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application. 5.8 For buildings under the IBC, above deck thermal insulation board must comply with the applicable standards listed in IBC Table 1508.2 or IRC Table R906.2, as applicable. 5.9 The roofing membranes are manufactured at Carlisle, Pennsylvania; Greenville, Illinois; Tooele, Utah; and Senatobia, Mississippi, under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with ICC-ES Acceptance Criteria for Membrane Roof-covering Systems (AC75), dated July 2010 (editorially revised April 2021). 7.0 IDENTIFICATION 7.1 The ICC-ES mark of conformity, electronic labeling, or the evaluation report number (ICC-ES ESR-1463) along with the name, registered trademark, or registered logo of the report holder or listee must be included in the product label. [Electronic labeling is the ICC-ES web address (www.icc-es.org); specific URL related to the report; or the ICC-ES machine-readable code placed on the aforementioned items.] 7.2 In, addition, tach roll of the roofing membrane must bear a label noting the product name, the manufacturer’s name (Carlisle SynTec Systems) or the name of the additional listee, the manufacturer’s address or plant code and the ICC-ES evaluation report number (ESR-1463). 7.3 The report holder’s contact information is the following: CARLISLE SYNTEC SYSTEMS, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA 17013 (717) 245-7000 www.carlislesyntec.com 7.4 The Additional Listees’ contact information is the following: MULE-HIDE PRODUCTS COMPANY, INC. 1195 PRINCE HALL DRIVE BELOIT, WISCONSIN 53511 (800) 786-1492 VERSICO, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC POST OFFICE BOX 1289 CARLISLE, PA 17013 (800) 992-7663 WEATHERBOND, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC POST OFFICE BOX 251 PLAINFIELD, PENNSYLVANIA 17081 (866) 471-5125 ROOFING PRODUCTS INTERNATIONAL, INC. 57460 DEWITT STREET ELKHART, INDIANA 46517 (800) 628-2957 ESR-1463 | Most Widely Accepted and Trusted Page 6 of 14 TABLE 1—PRODUCT NAMES CARLISLE PRODUCT NAME MULE-HIDE PRODUCT NAME VERSICO PRODUCT NAME WEATHERBOND PRODUCT NAME ROOFING PRODUCTS INTERNATIONAL PRODUCT NAME Sure-Seal EPDM Mule-Hide Standard Black EPDM VersiGard Non-reinforced EPDM WeatherBond EPDM Non- Reinforced Membrane Royal Edge Non- Reinforced EPDM Sure-Seal FR EPDM Mule-Hide FR EPDM VersiGard FR Non- Reinforced EPDM WeatherBond EPDM FR Non-Reinforced Membrane Royal Edge Non- Reinforced FR EPDM Sure-Seal FleeceBACK EPDM - VersiFleece EPDM WeatherBond Fleece EPDM Membrane Royal Edge EPDM FleeceBACK Sure-Seal AFX EPDM - VersiFleece AC EPDM WeatherBond EPDM AC Fleece Membrane - Sure-Tough EPDM Mule-Hide Standard Reinforced EPDM VersiGard Reinforced EPDM WeatherBond EPDM Reinforced Membrane Royal Edge Reinforced EPDM Sure-White EPDM Mule-Hide White-on- Black EPDM VersiGard –White Standard WeatherBond EPDM White Membrane Re-Flex White EPDM Sure-White Reinforced EPDM Mule-Hide White on Black Reinforced EPDM VersiGard White Reinforced EPDM WeatherBond EPDM White Reinforced Membrane - Sure-White FleeceBACK - - - Re-Flex White EPDM FleeceBACK Sure-Weld TPO Mule-Hide TPO-c VersiWeld Reinforced TPO Membrane WeatherBond TPO Membrane Re-Flex TPO Sure-Weld HS TPO Mule-Hide TPO-c (FR) VersiWeld HS WeatherBond TPO High Slope Membrane Re-Flex TPO HS Sure-Weld SAT-TPO Mule-Hide SA-TPO VersiWeld QA TPO Membrane WeatherBond TPO PAS Membrane Re-Flex TPO SAT Sure-Weld TPO FleeceBACK Mule-Hide TPO-c Fleece Back VersiFleece TPO WeatherBond FleeceTPO Membrane Re-Flex TPO FleeceBACK Sure-Weld TPO AFX Mule-Hide TPO-c Fleece Back Plus VersiFleece AC TPO WeatherBond TPO AC Fleece Membrane - Spectro-Weld TPO - - - - Spectro-Weld FleeceBACK TPO - - - - Sure-Flex PVC Mule-Hide PVC Membrane VersiFlex PVC WeatherBond PVC Membrane Re-Flex PVC Sure-Flex KEE HP Mule-Hide PVC KEE HP Membrane VersiFlex KEE HP WeatherBond KEE HP Membrane Re-Flex KEE HP Sure-Flex PVC FRS Mule-Hide PVC FRS Membrane VersiFlex FRS PVC WeatherBond PVC FRS Membrane Re-Flex FRS PVC Sure-Flex PVC FleeceBACK Mule-Hide PVC FleeceBack Membrane VersiFleece PVC WeatherBond PVC Fleece Membrane - Sure-Flex KEE HP FleeceBACK Mule-Hide PVC KEE HP Fleece Back Membrane VersiFleece KEE HP WeatherBond KEE HP Fleece Membrane - Sure-Flex PVC FRS FleeceBACK - VersiFleece FRS PVC WeatherBond PVC FRS Fleece Membrane Re-Flex FRS PVC FleeceBACK Sure-Flex KEE HP FRS FleeceBACK - VersiFleece FRS KEE HP WeatherBond KEE HP FRS Fleece Membrane - 90-8-30A Bonding Adhesive Mule-Hide Bonding Adhesive G200SA Yellow Substrate Adhesive LC-60 Bonding Adhesive Royal Edge Bonding Adhesive EPDM X-23 Low- VOC Bonding Adhesive EPDM X-23 Low VOC Bonding Adhesive EPDM X-23 Low VOC Bonding Adhesive EPDM X-23 Low VOC Bonding Adhesive - Aqua Base 120 Bonding Adhesive Aqua Base 120 Bonding Adhesive Aqua Base 120 Bonding Adhesive Aqua Base 120 Bonding Adhesive Royal Edge Water Based Bonding Adhesive Sure-Weld TPO Bonding Adhesive Mule-Hide TPO-c Bonding Adhesive VersiWeld TPO Bonding Adhesive TPO Bonding Adhesive Royal Edge EPDM/TPO Bonding Adhesive Low VOC Bonding Adhesive Low VOC Bonding Adhesive LOW VOC Bonding Adhesive Low VOC Bonding Adhesive Royal Edge Low VOC Bonding Adhesive Low VOC Bonding Adhesive 1168 Low VOC Bonding Adhesive 1168 Low VOC Bonding Adhesive 1168 Low VOC Bonding Adhesive 1168 -- Low VOC PVC Bonding Adhesive Low -VOC PVC Bonding Adhesive Low-VOC PVC Bonding Adhesive Low-VOC PVC Bonding Adhesive Re-Flex PVC Low VOC Bonding Adhesive HydroBond Water- Based Bonding Adhesive HydroBond Water- Based Bonding Adhesive- HydroBond Water-Based Bonding Adhesive HydroBond Water-Based Bonding Adhesive = CAV-GRIP III Low VOC Adhesive/Primer AeroWeb Adhesive Cav-Grip 3V Low VOC Adhesive/Primer Cav-Grip III Low VOC Adhesive/Primer - ESR-1463 | Most Widely Accepted and Trusted Page 7 of 14 TABLE 1—PRODUCT NAMES (continued) CARLISLE PRODUCT NAME MULE-HIDE PRODUCT NAME VERSICO PRODUCT NAME WEATHERBOND PRODUCT NAME ROOFING PRODUCTS INTERNATIONAL PRODUCT NAME Cold Applied Adhesive Cold Applied Adhesive Cold Applied Adhesive Cold Applied Adhesive RPI Cold Applied Adhesive Flexible FAST Adhesive Helix® Max Low-Rise Adhesive Flexible DASH Adhesive Flexible DASH Adhesive FastBond Flex Adhesive OlyBond 500 Adhesive - OlyBond 500 Adhesive OlyBond 500 Adhesive OlyBond 500 Adhesive TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS2,5 SYSTEM NO. ROOF CLASS DECK MAX SLOPE BARRIER BOARD OR SLIP SHEET INSULATION1 MEMBRANE 1 A Noncombustible 1/4:12 — Any of the following insulations, 1-inch min. thickness: Carlisle “SecurShield Polyiso”, “InsulBase”, Hunter Panels “H-Shield” or “H- Shield-CG” Sure-Weld, Spectro-Weld 2 1/2:12 Sure-Seal FR, Sure-Tough, Sure-White, Sure-Seal FleeceBACK, Sure-Weld HS, Sure-Weld SAT-TPO, Sure-Weld FleeceBACK, Spectro-Weld FleeceBACK, Sure-White FleeceBACK 3 3/4:12 Sure-Flex PVC FleeceBACK, Sure-Flex KEE HP FleeceBACK, Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBACK 4 1½ :12 Sure-Flex PVC, Sure-Flex PVC FRS, Sure-Flex KEE HP 5 A Noncombustible 3/4:12 — 1/2-inch-thick fiberboard4, 1/2-inch-thick fiberboard4 or barrier board (see Section 3.6) over 5-inch max Insulfoam EPS3, 1/2-inch-thick fiberboard or barrier board (see Section 3.6) over System No. 1 insulations Sure-White FleeceBACK 6 1:12 Sure-Seal FR, Sure-Tough 7 11/2:12 Sure-White, Sure-Seal FleeceBACK, Sure-Weld, Spectro-Weld, Sure-Weld HS, Sure-Weld SAT-TPO, Sure-Weld FleeceBACK, Spectro-Weld FleeceBACK, Sure-Flex PVC, Sure-Flex PVC FRS, Sure-Flex KEE HP, Sure-Flex PVC FleeceBACK, Sure-Flex KEE HP FleeceBACK, Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBACK 8 A Noncombustible or Combustible - min. 15/32-inch- thick plywood or min. 7/16-inch- thick OSB. 3/4:12 1/4-inch thick “DensDeck Prime” or 1/4-inch thick “SECUROCK Gypsum Fiber Roof Board” — Sure-White FleeceBACK 9 11/2:12 Sure-White, Sure-Seal FleeceBACK 10 3:12 Sure-Tough, Sure-Weld, Spectro-Weld, Sure-Weld FleeceBACK, Spectro-Weld FleeceBACK 11 4:12 Sure-Weld HS, Sure-Weld SAT-TPO 12 Unlimited Sure-Seal FR, Sure-Flex PVC, Sure-Flex PVC FRS, Sure-Flex KEE HP 13 3:12 Sure-Flex PVC FleeceBACK, Sure-Flex KEE HP FleeceBACK, Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBack ESR-1463 | Most Widely Accepted and Trusted Page 8 of 14 TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS2,5 (continued) SYSTEM NO. ROOF CLASS DECK MAX SLOPE BARRIER BOARD OR SLIP SHEET INSULATION1 MEMBRANE 14 A Combustible min. 15/32-inch- thick plywood or min. 7/16-inch- thick OSB. 1/4:12 Barrier board (see Section 3.6) or Slip sheet: 2 layers (see Section 3.7) Any of the following insulations, 1-inch min. thickness: Carlisle “SecurShield Polyiso”, ”InsulBase”, Hunter Panels “H-Shield” or “H-Shield- CG” Sure-Weld, Spectro-Weld 15 1/2:12 Sure-Seal FR, Sure-Tough, Sure-White, Sure-Seal FleeceBACK, Sure-Weld HS, Sure-Weld SAT-TPO, Sure-Weld FleeceBACK, Spectro-Weld FleeceBACK, Sure-White FleeceBACK 16 3/4:12 Sure-Flex PVC FleeceBACK, Sure-Flex KEE HP FleeceBACK, Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE FRS FleeceBACK 17 2:12 Sure-Flex PVC, Sure-Flex PVC FRS, Sure-Flex KEE HP 18 C Noncombustible or Combustible min. 15/32-inch- thick plywood or min. 7/16-inch- thick OSB. Unlimited — Any of the following insulations, min. 1- inch. thickness: Carlisle “InsulBase” or Hunter Panels “H-Shield” Any EPDM, PVC or TPO Membrane specified in this report 19 A Combustible 1/2:12 — Single layer of minimum 3.0" or double layer of minimum 1.5" Carlisle “SecurShield Polyiso” or Hunter Panels “H-Shield-CG” Any EPDM, PVC or TPO Membrane specified in this report 20 A Combustible 1/2:12 — Single layer of minimum 1.9" Carlisle “SecurShield Polyiso” or Hunter Panels “H-Shield-CG” Any EPDM, PVC or TPO Membrane specified in this report 21 A Noncombustible 1:12 — Min. 1/2- to 3-inch-thick Carlisle HP Recovery Board Sure-White Reinforced EPDM Membrane 22 A Combustible 11/2:12 1/2-inch-thick gypsum board or 1/4-inch- thick “DensDeck Roofboard” or “DensDeck Prime,” Any of the following insulations, 1-inch min. thickness: Carlisle “SecurShield Polyiso”,” InsulBase”, Hunter Panels “H-Shield” or “H-Shield- CG” Sure-White Reinforced EPDM Membrane For SI: 1 inch = 25.4 mm. 1All foam plastic insulation must be UL-classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2See Section 3.10 for adhesive application rate. 3UL Classified EPS may be installed below min. 1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope 1:12) or below min. 1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD (max slope 2:12) on noncombustible decks. 4Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure-Weld membrane, the slope is limited to max. 1/2:12. 5When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510], 2021, 2018 and 2015 IRC Section R908 [2012 and 2009 IRC Section R907], as applicable. ESR-1463 | Most Widely Accepted and Trusted Page 9 of 14 TABLE 3—FIRE CLASSIFICATION ASSEMBLIES—MECHANICALLY FASTENED ROOFING SYSTEMS4 SYSTEM NO. ROOF CLASS DECK MAX. SLOPE BARRIER BOARD OR SLIP SHEET INSULATION1 MEMBRANE/MAX. ROOF SLOPE 1 A Noncombustible 1/2:12 — Any of the following insulations, 1-inch min. thickness: Carlisle “SecurShield Polyiso” or “InsulBase”, Hunter Panels “H-Shield” or “H-Shield-CG” Sure-Tough, Sure-Weld, Spectro-Weld 2 11/2:12 Sure-Weld HS 3 21/2:12 Sure-Flex PVC, Sure-Flex KEE HP 4 A Noncombustible 1:12 — 1/2-inch-thick fiberboard3, 1/2-inch-thick fiberboard4 or barrier board (see Section 3.6) over 5-inch max Insulfoam EPS2, 1/2-inch-thick fiberboard or barrier board (see Section 3.6) over System No. 1 insulations Sure-Tough, Sure-Flex 5 11/2:12 Sure-Weld, Spectro-Weld, Sure-Weld HS 6 A Noncombustible 1/2:12 — Insulfoam SP, 5-inch max thickness Sure-Weld, Spectro-Weld, Sure-Weld HS, Sure-Flex, Sure-Flex KEE HP 7 A Noncombustible 1:12 — “Insulfoam SP” or min. ½- inch-thick Insulfoam EPS covered with “Insulfoam SP” Sure-Weld, Spectro-Weld, Sure-Weld HS, Sure-Tough 8 A Noncombustible or Combustible min.15/32-inch- thick plywood or min. 7/16-inch- thick OSB. 3:12 Barrier board (see Section 3.6) — Sure-Tough, Sure-Weld, Spectro-Weld 9 31/2:12 Sure-Tough FR 10 Unlimited Sure-Weld HS, Sure-Flex, Sure-Flex KEE HP 11 A Combustible min. 15/32-inch- thick plywood or min. 7/16-inch- thick OSB. 1/2:12 Barrier board (see Section 3.6) or Slip sheet: 2 layers, (see Section 3.7) Any of the following insulations, 1-inch min.to 6-inch max. thickness: Carlisle “SecurShield Polyiso“ or “InsulBase”, Hunter Panels “H-Shield” or “H-Shield-CG” Sure-Tough, Sure-Weld, Spectro-Weld 12 11/2:12 Sure-Weld HS 13 3/4:12 Sure-Tough FR 14 21/2:12 Sure-Flex PVC, Sure-Flex KEE HP 15 A Combustible min.15/32-inch- thick plywood or min. 7/16-inch- thick OSB 1:12 Slip sheet, 2 layers (see Section 3.7) — Sure-Tough 16 11/2:12 Sure-Tough FR, Sure Weld, Spectro-Weld, Sure-Weld HS, Sure-Flex, Sure-Flex KEE HP 17 B Combustible min.15/32-inch- thick plywood or min. 7/16-inch- thick OSB. 11/2:12 Slip sheet, 1 layer (see Section 3.7) — Sure-Tough, Sure-Tough FR, Sure-Weld, Spectro-Weld, Sure-Weld HS, Sure-Flex, Sure-Flex KEE HP 18 C Combustible min 15/32-inch- thick plywood or min. 7/16-inch- thick OSB. Unlimited — Any of the following insulations, 1-inch min. thickness: Carlisle “SecurShield Polyiso” or “InsulBase”, Hunter Panels “H-Shield” or H-Shield CG” Any EPDM, PVC or TPO Membrane specified in this report 19 A Combustible 1/2:12 — Single layer or double layer of minimum 1-inch Carlisle “SecurShield Polyiso” or Hunter Panels “H-Shield-CG” Any EPDM, PVC or TPO Membrane specified in this report 20 A Combustible 1:12 — Minimum 1/2-inch Carlisle “SecurShield HD,” ”SecurShield HD Plus,” ”SecurShield HD NH”, ”SecurShield HD Plus NH”, ”SecurShield HD Plus”, or ”SecurShield HD RL” Any EPDM, PVC or TPO Membrane specified in this report 21 A Noncombustible 1:12 — Any of the following insulations, 1-inch min. thickness: Carlisle “SecurShield Polyiso” or “InsulBase”, Hunter Panels “H-Shield” or “H-Shield-CG” Sure-White Reinforced EPDM Membrane ESR-1463 | Most Widely Accepted and Trusted Page 10 of 14 TABLE 3—FIRE CLASSIFICATION ASSEMBLIES—MECHANICALLY FASTENED ROOFING SYSTEMS4 (continued) SYSTEM NO. ROOF CLASS DECK MAX. SLOPE BARRIER BOARD OR SLIP SHEET INSULATION1 MEMBRANE/MAX. ROOF SLOPE 22 A Combustible 2:12 1/2-inch-thick gypsum board or 1/4-inch- thick “DensDeck Roofboard” or “DensDeck Prime,” Any of the following insulations, 1-inch min. thickness: Carlisle “SecurShield Polyiso,” “InsulBase”, Hunter Panels “H-Shield” or “H-Shield-CG” Sure-White Reinforced EPDM Membrane 23 A Noncombustible 1/2:12 — Any of the following insulations, 1-inch min. thickness: Carlisle “SecurShield Polyiso,” ”InsulBase”, Hunter Panels “H-Shield” or “H-Shield-CG” Sure-White Reinforced EPDM Membrane For SI: 1 inch = 25.4 mm. 1All foam plastic insulation must be UL-classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2UL Classified EPS may be installed below min. 1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope 1:12) or below min. 1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD (max slope 2:12) on noncombustible decks. 3Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure-Weld membrane, the slope is limited to 1/2:12. 4When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510], 2021, 2018 and 2015 IRC Section R908 [2012 and 2009 IRC Section R907], as applicable. TABLE 4—WIND RESISTANCE—ADHERED ASSEMBLIES5,6 SYSTEM NO. ALLOWABLE WIND UPLIFT (FIELD) (psf) DECK2 INSULATION / MIN. THICKNESS1,3 INSULATION FASTENING RATE MEMBRANE TYPE 1 45 Combustible or Noncombustible 1/2-inch fiberboard4, 15/32-inch OSB, or 1/4-inch thick “DensDeck Prime” or 1/4-inch thick “SECUROCK Gypsum Fiber Roof Board” 1 per 2 ft2 EPDM, PVC and TPO Membranes 2 45 Combustible or Noncombustible Carlisle “InsulBase” or “SecurShield Polyiso”; Hunter Panels “H-Shield” or “H-Shield-CG” / 1.4 inch with 1/2-inch SECUROCK coverboard (optional) 1 per 3.2 ft2 EPDM, PVC and TPO Membranes 3 45 Combustible or Noncombustible Carlisle “InsulBase” or “SecurShield Polyiso”; Hunter Panels “H-Shield” or “H-Shield-CG” / 2.0 inch with 5/8-inch SECUROCK coverboard (optional) 1 per 4 ft2 EPDM, PVC and TPO Membranes 4 68 Combustible or Noncombustible Carlisle “InsulBase” or “SecurShield Polyiso”; Hunter Panels “H-Shield” or “H-Shield-CG” / 1.0 inch FAST Adhesive FleeceBACK Membranes 5 75 Combustible or Noncombustible Carlisle “InsulBase” or “SecurShield Polyiso”; Hunter Panels “H-Shield” or “H-Shield-CG” / 2.0 inch with 1/2-inch SECUROCK coverboard (optional) 1 per 1.6 ft2 EPDM, PVC and TPO Membranes 6 113 Combustible or Noncombustible Carlisle “SecurShield” or “H-Shield CG” / 2.0 inch 1 per 1ft2 PVC Membranes 7 120 Combustible or Noncombustible Carlisle “InsulBase” or “SecurShield Polyiso”; Hunter Panels “H-Shield” or “H-Shield-CG” / 2.0 inch 1 per 1 ft2 TPO Membranes EPDM membranes (with noncombustible deck only) 8 128 Combustible or Noncombustible Carlisle “InsulBase” or “SecurShield Polyiso”; Hunter Panels “H-Shield” or “H-Shield-CG” / 2.0 inch with 1/2-inch SECUROCK coverboard (optional) 1 per 1 ft2 EPDM and TPO Membranes 9 135 Combustible or Noncombustible Carlisle “InsulBase” or “SecurShield Polyiso”; Hunter Panels “H-Shield” or “H-Shield-CG” / 2.0 inch with 1/2-inch SECUROCK coverboard (optional) 1 per 1 ft2 FleeceBACK Membranes 10 143 Combustible or Noncombustible 1/2-inch DensDeck Prime 1 per 1 ft2 FleeceBACK Membranes For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa 1All foam plastic insulation must be UL-classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2Steel deck must be minimum No. 22 gage galvanized steel [base-metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive strength (f´c) of 2500 psi. See Section 5.6 of this report. 3UL Classified EPS may be installed below min. 1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope 1:12) or below min. 1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD (max slope 2:12) on noncombustible decks. 4Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure-Weld membrane, the slope is limited to 1/2:12. 5When application is over existing roofs, documentation of the wind-uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application. Since the composition and/or condition of any particular existing underlying material may vary widely, reroofing with fully adhered System No. 4 is outside the scope of this report. For reroofing or recovering, installation must be in accordance with 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510], 2021, 2018 and 2015 IRC Section R908 [2012 and 2009 IRC Section R907], as applicable. 6See Section 3.10 for adhesive application rate. ESR-1463 | Most Widely Accepted and Trusted Page 11 of 14 TABLE 5—WIND RESISTANCE—MECHANICALLY FASTENED ASSEMBLIES4,7 SYSTEM NO. MAXIMUM ALLOWABLE WIND UPLIFT (psf) DECK3 INSULATION 5 MEMBRANE MEMBRANE FASTENING MAXIMUM FASTENER SPACING (inches) MAXIMUM FASTENER ROW SPACING8 1 45 Noncombustible Foam plastic insulation1,2, 1/2-inch-thick fiberboard6 or barrier board (See Sect. 3.6) Sure-Tough HP-X Fastener & Metal Fastening Bar 12 6 ft 6 inches 2 75 Noncombustible Same as System No. 1 Sure-Tough HP-X Fastener & Metal Fastening Bar 6 6 ft 6 inches 3 52 Noncombustible Same as System No. 1 Sure-Tough HP Fastener & Polymer Seam Plate 6 9 ft 6 inches 4 45 Noncombustible Same as System No. 1 Sure-Tough Sure-Tite Fastener & ST Fastening Bar 12 9 ft 6 inches 5 30 Noncombustible Same as System No. 1 Sure-Tough (75 mil) HP Fastener & Polymer Seam Plate 12 9 ft 6 inches 6 60 Noncombustible Same as System No. 1 Sure-Tough (75 mil) HP Fastener & Polymer Seam Plate 6 9 ft 6 inches 7 45 Noncombustible Same as System No. 1 Sure-Weld or Spectro-Weld HP-X or HP-Xtra Fasteners with Piranha or Piranha Xtra Plates 12 7 ft 6 inches 8 45 Noncombustible Same as System No. 1 Sure-Weld or Spectro-Weld HP-Xtra Fasteners with Piranha Xtra Plates 12 9 ft 6 inches 9 60 Noncombustible Same as System No. 1 Sure-Weld or Spectro-Weld HP-X or HP-Xtra Fasteners with Piranha or Piranha Xtra Plates 6 9 ft 6 inches 10 67 Noncombustible Same as System No. 1 Sure-Weld or Spectro-Weld HP-X or HP-Xtra Fasteners with Piranha or Piranha Xtra Plates 6 7 ft 6 inches 11 30 Noncombustible Same as System No. 1 Sure-Weld or Spectro-Weld HP-X or HP-Xtra Fasteners with Piranha or Piranha Xtra Plates 12 11 ft 6 inches 12 60 Noncombustible Same as System No. 1 Sure-Weld or Spectro-Weld HP-X or HP-Xtra Fasteners with Piranha or Piranha Xtra Plates 6 11 ft 6 inches 13 53 Noncombustible Same as System No. 1 Sure-Flex PVC or Sure-Flex KEE HP HP-X Fasteners with Piranha Plates 6 6 ft 4 inches 14 83 Noncombustible Same as System No. 1 Sure-Flex PVC or Sure-Flex KEE HP HP-X Fasteners with Piranha Plates 6 2 ft 11 inches 15 30 Noncombustible Same as System No. 1 Sure-Flex PVC or Sure-Flex KEE HP HP-X or HP-Xtra Fasteners with Piranha or Piranha Xtra Plates 18 6 ft 4 inches 16 45 Noncombustible Same as System No. 1 Sure-Flex PVC or Sure-Flex KEE HP HP-X or HP-Xtra Fasteners with Piranha or Piranha Xtra Plates 12 6 ft 4 inches 17 53 Noncombustible Same as System No. 1 Sure-Flex PVC or Sure-Flex KEE HP HP-X Fasteners with Piranha Plates 12 2 ft 11 inches 18 60 Noncombustible Same as System No. 1 Sure-Flex PVC or Sure-Flex KEE HP HP-X or HP-Xtra Fasteners with Piranha Plates 6 9 ft 7 inches 19 45 Noncombustible Same as System No. 1 Sure-Weld HP-X Fasteners with OMG RhinoBond Plates 1 per 5.3 ft2 N/A 20 60 Noncombustible Same as System No. 1 Sure-Weld HP-X Fasteners with OMG RhinoBond Plates 1 per 4 ft2 N/A For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa. 1Foam plastic insulation must be any of the following (1-inch min. to 6-inch max. thickness): Carlisle “SecurShield Polyiso”, “InsulBase” Hunter Panels “H-Shield” or Hunter Panels “H-Shield- CG”. 2All foam plastic insulation must be UL-classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 3Steel deck must be minimum No. 22 gage galvanized steel [base-metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive strength (f′c) of 2500 psi. See Section 5.6 of this report. 4For existing metal roofing, the assemblies listed must be installed by fastening through the roofing and into structural members (purlins, angle iron, beams, etc.) capable of resisting all expected loads. The maximum allowable wind uplift (field) pressures are shown in Column 2. 5UL Classified EPS may be installed below min. 1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below min. 1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD (max slope 2:12) on noncombustible decks. 6Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure-Weld membrane, the slope is limited to 1/2:12. 7When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510], 2021, 2018 and 2015 IRC Section R908 [2012 and 2009 IRC Section R907], as applicable. 8Fastener row spaces shown are for field of roof only. See Section 4.3 for recognized fascia systems for mechanically fastened roof assemblies. Distance between the edge of the roof and the first row of fasteners must be determined accordingly. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2023 ICC Evaluation Service, LLC. All rights reserved. Page 12 of 14 ICC-ES Evaluation Report ESR-1463 LABC and LARC Supplement Reissued October 2022 Revised May 2023 This report is subject to renewal October 2023. www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC SYSTEMS, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE-PLY ROOFING MEMBRANES 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes, described in ICC-ES evaluation report ESR-1463, have also been evaluated for compliance with the codes noted below as adopted by the Los Angeles Department of Building and Safety (LADBS). Applicable code editions:  2023 City of Los Angeles Building Code (LABC)  2023 City of Los Angeles Residential Code (LARC) 2.0 CONCLUSIONS The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463, comply with the LABC Chapters 7A and 15, the LARC Section R337 and LARC Chapter 9, and are subjected to the conditions of use described in this supplement. 3.0 CONDITIONS OF USE The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes, described in this evaluation report must comply with all of the following conditions:  All applicable sections in the evaluation report ESR-1463.  The design, installation, conditions of use and identification are in accordance with the 2021 International Building Code® (IBC) and 2021 International Residential Code® (IRC) provisions noted in the evaluation report ESR-1463.  The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, or LARC Chapter 3, as applicable.  The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes must not be installed over existing wood shakes or wood shingles in accordance with LABC Section 1512.  The installation of the Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes must comply with City of Los Angeles Information Bulletin P/BC 2020-16, “Dwellings in High Wind Velocity Areas (HWA)”.  Reroofing applications must comply with Sections 4.2.2, 4.3.2 and 5.7 of the evaluation report ESR-1463 and LABC Section 1512 or LARC Section R908, as applicable. Where spaced sheathing exists, a minimum of 15/32-inch-thick (11.9 mm) plywood shall be installed prior to roofing installations.  Where moderate or heavy foot traffic occurs for maintenance of equipment, the roof covering shall be adequately protected. ESR-1463 LABC and LARC Supplement | Most Widely Accepted and Trusted Page 13 of 14  The Building Inspector shall be notified 24 hours in advance prior to installation of the roof membranes.  The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2018 International Building Code® (IBC) provisions noted in the evaluation report and the additional requirements of Sections 701A.3 and 705A of the LABC.  The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2018 International Residential Code® (IRC) provisions noted in the evaluation report and the additional requirements of Sections R337.1.3 and R337.5 of the LARC. This supplement expires concurrently with the evaluation report, reissued October 2022 and revised May 2023. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2023 ICC Evaluation Service, LLC. All rights reserved. Page 14 of 14 ICC-ES Evaluation Report ESR-1463 CBC and CRC Supplement Reissued October 2022 Revised May 2023 This report is subject to renewal October 2023. www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC SYSTEMS, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE-PLY ROOFING MEMBRANES 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Carlisle EPDM, PVC and TPO single-ply roofing membranes, described in ICC-ES evaluation report ESR-1463, have also been evaluated for compliance with the codes noted below. Applicable code editions:  2022 California Building Code (CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD) AKA: California Department of Health Care Access and Information (HCAI) and the Division of State Architect (DSA), see Sections 2.1.1 and 2.1.2 below.  2022 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC: The Carlisle EPDM, PVC and TPO single-ply roofing membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463, comply with CBC Chapter 15, provided the design and installation are in accordance with the 2021 International Building Code® (IBC) provisions noted in the evaluation report and the additional requirements of CBC Chapter 15, as applicable. The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2021 International Building Code® (IBC) provisions noted in the evaluation report and the additional requirements of Sections 701A.3 and 705A of the CBC. 2.1.1 OSHPD: The applicable OSHPD Sections of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections of the CBC are beyond the scope of this supplement. 2.2 CRC: The Carlisle EPDM, PVC and TPO single-ply roofing membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463, comply with CRC Chapter 95, provided the design and installation are in accordance with the 2021 International Residential Code® (IRC) provisions noted in the evaluation report and the additional requirements of CRC Chapter 9, as applicable. The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2021 International Residential Code® (IRC) provisions noted in the evaluation report and the additional requirements of Sections R337.1.3 and R337.5 of the CRC. This supplement expires concurrently with the evaluation report, reissued October 2022 and revised May 2023.