HomeMy WebLinkAboutFile Documents.624 E Cooper Ave.0040-2024-BCOM (10)Project Title: zig zag restaurant Report date: 09/25/24
Data filename: Page 1 of 2
Generated by COMcheck-Web Software
Interior Lighting Compliance
Certificate
Section 1: Project Information
Energy Code: 2009 IECC
Project Title: zig zag restaurant
Project Type: Alteration
Construction Site:Owner/Agent:Designer/Contractor:
Section 2: Interior Lighting and Power Calculation
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B x C)
restaurant (Retail): Exempt
Total Allowed Watts =N/A
Area Category Exemption Qualifications
Total Wattage Total Pre-Alt.# Fixtures
Activity Area Pre-Alt.Post-Alt.Fixtures Repl./Added
restaurant (Retail, 1500 sq.ft.): Exemption: Less than 50% fixture
replacement.
13900 4000 278 6
Section 3: Interior Lighting Fixture Schedule
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
D
Fixture
Watt.
E
(C X D)
restaurant (Retail, 1500 sq.ft.): Exempt
LED: chandeliers: LED PAR 20W:6 2 60 120
LED: pendants: LED A Lamp 25W:1 10 60 600
LED: sconces: LED A Lamp 25W:1 6 60 360
Total Proposed Watts =N/A
Section 4: Requirements Checklist
Interior Lighting PASSES
Lighting Wattage:
❑1.Total proposed watts must be less than or equal to total allowed watts.
Allowed Watts Proposed Watts Complies N/A N/A Passes
Controls, Switching, and Wiring:
❑2.Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to
vertical fenestration.
❑3.Daylight zones have individual lighting controls independent from that of the general area lighting.
Exceptions:
❑Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device.
❑Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a
separate switch for general area lighting.
ComCheck needs to be redone - the current
code is the 2021 IECC, the space is not exempt
under that code, and project info needs to be
completely filled out (site, owner/agent,
designer/contractor).
Provide specs on all
proposed light fixtures and
highlight max fixture
wattage and NRTL listing
Project Title: zig zag restaurant Report date: 09/25/24
Data filename: Page 2 of 2
❑4. Independent controls for each space (switch/occupancy sensor).
Exceptions:
❑Areas designated as security or emergency areas that must be continuously illuminated.
❑Lighting in stairways or corridors that are elements of the means of egress.
❑5. Master switch at entry to hotel/motel guest room.
❑6. Individual dwelling units separately metered.
❑7. Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control
of the nonexempt lighting.
❑8. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either
controlling all luminaires, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switching the middle
lamp luminaires independently of other lamps, or switching each luminaire or each lamp.
Exceptions:
❑Only one luminaire in space.
❑An occupant-sensing device controls the area.
❑The area is a corridor, storeroom, restroom, public lobby or sleeping unit.
❑Areas that use less than 0.6 Watts/sq.ft.
❑9. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft.
Exceptions:
❑Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security.
❑10.Photocell/astronomical time switch on exterior lights.
Exceptions:
❑Lighting intended for 24 hour use.
❑11.Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts).
Exceptions:
❑Electronic high-frequency ballasts; Luminaires on emergency circuits or with no available pair.
Section 5: Compliance Statement
Compliance Statement: The proposed lighting alteration project represented in this document is consistent with the building plans,
specifications and other calculations submitted with this permit application. The proposed lighting alteration project has been designed to meet
the 2009 IECC, Chapter 8, requirements in COMcheck-Web and to comply with the mandatory requirements in the Requirements Checklist.
Name - Title Signature Date
Project Notes:
new lighting upgrades
jeffrey halferty jeffrey halferty 9/25/24