File Documents.309 Oak Ln.0021-2022-BRES (18)
EENERGY Job: 309 Oak Lane I INNOVATIONS Project Summary Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email: max@a eiboulder.com Web:www.eiboulder.com Project Information For: Hans Preiss, Bright Sense Notes: Desi• n Information Weather: Basalt, CO Winter Design Conditions Summer Design Conditions Outside db -15 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 85 °F Design TD 16 °F Daily range H Relative humidity 50 Moisture difference -39 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19879 Btuh Structure 13296 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (SER=70% 54 cfm) 1177 Btuh Central vent (SER=70% 54 cfm) 222 Btuh Heat recovery Heat recovery Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21056 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load 12977 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 445 Btuh Ducts 0 Btuh Central vent (54 cfm) -1099 Btuh Heating Cooling Heat recovery Area (ft2) 1609 1609 Equipment latent load 0 Btuh Volume (ft3) 18051 18051 Air changes/hour 0.18 0.09 Equipment Total Load (Sen+Lat) 12977 Btuh Equiv. AVF (cfm) 54 27 Req. total capacity at 0.85 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Arctic Make Arctic Trade Trade Model HP-035ZA/BE Cond HP-035ZA/BE AHRI ref Coil AHRI ref Efficiency 10 HSPF Efficiency 0 SEER Heating input Sensible cooling 20591 Btuh Heating output 28320 Btuh @ 47°F Latent cooling 3634 Btuh Temperature rise 0 °F Total cooling 24225 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0 Capacity balance point = 0 °F Backup: Input = 8 kW, Output = 26188 Btuh, 100 AFUE Bold/italic values have been manually overridden jj .fl_ -, YYr Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w rig hatsoft' 2011N/i-09'0�20 2 2 .4— ^M ,.e�,�„_„-- �, Right-Suite®Universal 2021 21.0.07 RSU20087 l page 1 ..\309 Oak Lane\309 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N rEVE /2022 J ASPEN FORDODECUMINU j imp BUILDING DEPARTMENT Ei AED Assessment Job: 309 Oak Lane I Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email: max@°eiboulder.com Web:www.eiboulder.com Project Information For: Hans Preiss, Bright Sense Design Conditions Location: Indoor: Heating Cooling Basalt, CO Indoor temperature (°F) 70 75 Elevation: 6611 ft Design TD (°F) 85 16 Latitude: 39°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 39.3 -38.5 Dry bulb(°F) -15 91 Infiltration: Daily range (°F) - 27 ( H ) Wet bulb (°F) - 59 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 9,000— 8,000 — 7,000— 6,000 \\. 78 s,000— 4,00 3,000— 2,000 1,000 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day /Hourly /Aserege /AEDllmlr Maximum hourly glazing load exceeds average by 39.9%. House does not have adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 614 Btuh (PFG - 1.3*AFG) Bold/italic values have been manually overridden I\1E D wrightsoft- "2II�° 0 :33:35 ,.�- ^M.=-k-,.-k^.-H...my Right-Suite®Universal 2021 21.0.07 RSU20087 p ACCP. ...\309 Oak Lane\309 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N ;��t{4 ��(,�p 01/1 9/ b 2 2 Illl[t1��i09/28/2022 yj ASPEN FOROUGUIRINte j imp BUILDING DEPARTMENT 309 E. ENERGY BuildingAnalysis Job: Nov0, Lane I INNOVATIONS y Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email:max@eiboulder.com Web:www.eiboulder.com Pro'ect Information For: Hans Preiss, Bright Sense Desi• n Conditions Location: Indoor: Heating Cooling Basalt, CO Indoor temperature (°F) 70 75 Elevation: 6611 ft Design TD (°F) 85 16 Latitude: 39°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 39.3 -38.5 Dry bulb(°F) -15 91 Infiltration: Daily range (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 59 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin • Component Btuh/ft2 Btuh % of load Walls 2.6 6300 29.9 ventilation Glazing 14.4 5599 26.6 Doors 0 0 0 Walls Infiltration Ceilings 1.5 2002 9.5 Floors 1.6 2012 9.6 Infiltration 1.5 3965 18.8 Ducts 0 0 Piping 0 0 Floors Humidification 0 0 Ventilation 1177 5.6 Adjustments 0 Ceilings Total 21056 100.0 Glazing Coolin• Component Btuh/ft2 Btuh % of load Walls 0.5 1271 9.4 Walls Other Glazing 19.7 7637 56.5 Doors 0 0 0 Internal Gains Ceilings 0.6 765 5.7 Floors 0 0 0 Infiltration 0.1 373 2.8 Ducts 0 0 Infiltration Ventilation 222 1.6 Internal gains 3250 24.0 Ceilings Blower 0 0 Glazing Adjustments 0 Total 13518 100.0 Latent Cooling Load = 0 Btuh Overall U-value= 0.034 Btuh/ft2-°F Data entries checked. Bold/italic values have been manually overridden wrightsaft- 2021-Nov-10 20:33:35 A......_ ^^^,.,.-,..-',,,,-°,cor,,°, Right-Suite®Universal 2021 21.0.07 RSU20087 p 2022 ACCP. ...\309 Oak Lane\309 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N rTI) '����p��+ 0 /19/8/2022 J ASPEN FORDODECUIRINU limp BUILDING DEPARTMENT EENERGY Component Constructions Job: 309 Oak Lane I INNOVATIONS Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email. max@eiboulder.com Web:www.eiboulder.com Project Information For: Hans Preiss, Bright Sense Design Conditions Location: Indoor: Heating Cooling Basalt, CO Indoor temperature (°F) 70 75 Elevation: 6611 ft Design TD (°F) 85 16 Latitude: 39°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 39.3 -38.5 Dry bulb(°F) -15 91 Infiltration: Daily range (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 59 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btu h/ft,°F ft,°F/Btuh Btuh/fr Btuh Btuh/ft2 Btuh Walls ICF R19 below grade:ICF wall, R19 ne 94 0.037 19.0 3.73 351 0.57 54 se 236 0.037 19.0 3.71 875 0.55 130 sw 59 0.037 19.0 3.84 226 0.68 40 nw 199 0.037 19.0 3.83 762 0.67 134 all 588 0.037 19.0 3.77 2214 0.61 357 R35 cavity and R10:R35 cavity and R10 ext continuous ne 241 0.026 45.0 2.22 537 0.50 120 se 875 0.026 45.0 2.22 1945 0.50 435 sw 208 0.026 45.0 2.22 462 0.50 103 nw 513 0.026 45.0 2.22 1142 0.50 255 all 1838 0.026 45.0 2.22 4086 0.50 913 Partitions (none) Windows U17 S23:typical triple pane;6.67 ft head ht ne 36 0.170 0 14.5 520 17.1 614 se 39 0.170 0 14.4 564 20.7 809 all 75 0.170 0 14.4 1084 19.0 1423 U17 S23:typical triple pane;0.6 ft overhang(2 ft window ht, 1.1 ft se 12 0.170 0 14.4 173 20.7 249 sep.);6.67 ft head ht U17 S23:typical triple pane;0.6 ft overhang(3 ft window ht, 1.1 ft se 9 0.170 0 14.5 130 20.7 187 sep.);6.67 ft head ht se 12 0.170 0 14.4 173 20.7 249 se 18 0.170 0 14.5 260 20.7 373 all 39 0.170 0 14.5 564 20.7 809 U17 S23:typical triple pane;0.6 ft overhang(3.5 ft window ht, 1.1 ft se 14 0.170 0 14.4 202 20.7 290 sep.);6.67 ft head ht U17 S23:typical triple pane; 1.7 ft overhang(5.5 ft window ht,3.4 ft sw 33 0.170 0 14.4 477 20.7 685 sep.);6.67 ft head ht U17 S23:typical triple pane;2.2 ft overhang(6 ft window ht,0 ft sep.); sw 36 0.170 0 14.5 520 14.5 523 6.67 ft head ht U17 S23:typical triple pane; 1.6 ft overhang(6 ft window ht, 1.3 ft nw 37 0.170 0 14.4 527 17.1 622 sep.);6.67 ft head ht U17 S23:typical triple pane; 1.6 ft overhang(6 ft window ht, 1.4 ft nw 54 0.170 0 14.4 780 17.1 921 sep.);6.67 ft head ht REC E;WED el.,_ w rig htsoft- 2021-Nov-10 20:33:35 ,,,,,,.. ., =wavy w Right-Suite®Universal 2021 21.0.07 RSU20087 (�P ACCP. ...\309 Oak Lane\309 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N REVAISNETI) 1 19�g�}� L V 2 2 09/28/2022 ASPEN ` `O0MIIKINICE j imp BUILDING DEPARTMENT U17 S23:typical triple pane;9.1 ft overhang(8 ft window ht,2.5 ft nw 24 0.170 0 14.4 347 17.1 409 sep.);6.67 ft head ht nw 64 0.170 0 14.4 925 17.1 1091 all 88 0.170 0 14.4 1272 17.1 1501 Doors (none) Ceilings R70 vaulted:Rf/clg ceiling,mtl roof mat,frm cons, 1/2"gypsum board 1305 0.018 70.0 1.53 2002 0.59 765 int fnsh, 14"thkns,r-70 ceil ins Floors 21 B-32t:Bg floor,heavy dry or light damp soil,prm ext ins coy,4' 1042 0.014 3.0 1.19 1239 0 0 depth,r-30 ins 22D-15tpm:Bg floor,heavy dry or light damp soil,prm ext ins coy,on 31 0.298 15.0 25.3 773 0 0 grade depth,r-15 edge ins,r-30 ins RECEIVED el.,_ wrightsoft- 2021-Nov-10 20:33:35 .... ,.., .,.......1,M, Right-Suites Universal 2021 21.0.07 RSU20087 A P 4� ACCP. ...\309 Oak Lane\309 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N reWria 01/197L622 f-}/2022 J ASPEN FOROUGUIRINU j imp BUILDING DEPARTMENT ' ENERGY RIg ht-J8® Form J1 Job: 309 Oak Lane GI INNOVATIONS Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email:max@eiboulder.com Web:www.eiboulder.com 1 Name of Room Entire House Living 2 Running Feet of Exposed Wall 210.3 ft 53.5 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 12.1 ft 5105.5 ft2 15.5 ft 1199.5 ft2 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 1608.6 ft2 1.0 x 392.5 ft 392.5 ft2 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 12.3 ° 2536.5 ft2 0 ° 823.8 ft2 Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall ICF R19 below grade ne 3.73 0.57 94 351 54 50 191 34 . Wall R35 cavity and R10 ne 2.22 0.50 277 537 120 144 241 54 I Glaz U17 S23 ne 14.45 17.05 36 520 614 36 520 614 Wall ICF R19 below grade se 3.71 0.55 236 875 130 0 0 0 11 Wall R35 cavity and R10 se 2.22 0.50 979 1945 435 212 471 105 -Glaz U17 S23 se 14.45 20.75 12 173 249 0 0 0 -Glaz U17 S23 se 14.45 20.75 39 564 809 0 0 0 -Glaz U17 S23 se 14.45 20.75 9 130 187 0 0 0 -Glaz U17 S23 se 14.45 20.75 12 173 249 0 0 0 -Glaz U17 S23 se 14.45 20.75 18 260 373 0 0 0 -Glaz U17 S23 se 14.45 20.75 14 202 290 0 0 0 Wall ICF R19 below grade sw 3.84 0.68 59 226 40 15 57 10 Wall R35 cavity and R10 sw 2.22 0.50 277 462 103 33 73 16 -Glaz U17 S23 sw 14.45 20.75 33 477 685 0 0 0 Glaz U17 S23 sw 14.45 14.53 36 520 523 0 0 0 Wall ICF R19 below grade nw 3.83 0.67 199 762 134 199 762 134 Wall R35 cavity and R10 nw 2.22 0.50 692 1142 255 274 408 91 Glaz U17 S23 nw 14.45 17.05 37 527 622 37 527 622 -Glaz U17 S23 nw 14.45 17.05 54 780 921 54 780 921 Glaz U17 S23 nw 14.45 17.05 24 347 409 0 0 0 Glaz U17 S23 nw 14.45 17.05 64 925 1091 0 0 0 Ceil R70 vaulted - 1.53 0.59 1305 2002 765 431 662 253 Flor 21B-32t - 1.19 0.00 1042 1239 0 393 467 0 Flor 22D-15tpm - 25.33 0.00 190 773 0 0 0 0 Infiltration Heating Load(Btuh) 0.18 3965 1300 - Effect WAR WAR - 12 Sensible Load(Btuh) ACH 1.00 373 0.33 122 0.09 Latent Load(Btuh) -555 Internal a Occupants at 230 and 200 Btuh 5 1150 1000 0 0 0 b Scenario number 2100 900 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 19879 13296 445 6461 3963 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 54 E Cfm 54 1177 222 -1099 17 Winter Humidification Load Gal/Day 0 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion&Latent Moisture Migration Load 614 86 21 Total Load Sum lines 13 through 19 21056 13518 0 646.1-. 63,E � , fVED Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �� Oak Lane\309 ���^^^yyy 204Lt090!32Q 22 ACCA .A309 O ---- Right-Suite®Universal 2021 21.0.07 RSU20087 rgEwiewe Page 1 _ w t�, 09 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N 09/28/2022- ASPEN FORCOMCCIMANCE 1 imp BUILDING DEPARTMENT imp ' ENERGY RIg ht-J8® Form J1 Job: 309 Oak Lane GI INNOVATIONS Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email:max@eiboulder.com Web:www.eiboulder.com 1 Name of Room Bed 2 Bath 1 2 Running Feet of Exposed Wall 21.8 ft 5.5 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 8.0 ft 348.0 ft2 8.0 ft 264.0 ft2 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 11.0 x 10.8 ft 118.3 ft2 11.0 x 5.5 ft 60.5 ft2 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 118.3 ft2 0 ° 60.5 ft2 Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall ICF R19 below grade ne 3.73 0.57 44 159 20 0 0 0 . Wall R35 cavity and R10 ne 2.22 0.50 44 98 22 0 0 0 I Glaz U17 S23 ne 14.45 17.05 0 0 0 0 0 0 Wall ICF R19 below grade se 3.71 0.55 43 156 19 22 80 10 11 Wall R35 cavity and R10 se 2.22 0.50 43 69 15 22 36 8 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 12 173 249 6 87 124 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 Wall ICF R19 below grade sw 3.84 0.68 0 0 0 0 0 0 Wall R35 cavity and R10 sw 2.22 0.50 0 0 0 0 0 0 -Glaz U17 S23 sw 14.45 20.75 0 0 0 0 0 0 Glaz U17 S23 sw 14.45 14.53 0 0 0 0 0 0 Wall ICF R19 below grade nw 3.83 0.67 0 0 0 0 0 0 Wall R35 cavity and R10 nw 2.22 0.50 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 -Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Ceil R70 vaulted - 1.53 0.59 0 0 0 0 0 0 Flor 21B-32t - 1.19 0.00 118 141 0 61 72 0 Flor 22D-15tpm - 25.33 0.00 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0.18 198 50 - Effect WAR WAR 12 Sensible Load(Btuh) ACH 0.05 19 0.01 5 0.09 Latent Load(Btuh) Internal a Occupants at 230 and 200 Btuh 1 230 200 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 993 557 324 151 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 54 E Cfm 54 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load -18 4 21 Total Load Sum lines 13 through 19 993 557 324. E ,��5� � fVED Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �� Oak Lane\309 ���^^^yyy 2014w�904n 22 ACCA .A309 O.r'9 Right-Suite®Universal 2021 21.0.07 RSU20087 rgEwiewe Page 2 _ w t�, 09 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N 09/28/2022- ASPEN FORCOMCCIMANCE 1 imp BUILDING DEPARTMENT imp ' ENERGY RIg ht-J8® Form J1 Job: 309 Oak Lane GI INNOVATIONS Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email:max@eiboulder.com Web:www.eiboulder.com 1 Name of Room Bed 1 W/D/Mech. 2 Running Feet of Exposed Wall 10.5 ft 7.5 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 8.0 ft 344.0 ft2 8.0 ft 296.0 ft2 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 11.0 x 10.5 ft 115.5 ft2 11.0 x 7.5 ft 82.5 ft2 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 115.5 ft2 0 ° 82.5 ft2 Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall ICF R19 below grade ne 3.73 0.57 0 0 0 0 0 0 . Wall R35 cavity and R10 ne 2.22 0.50 0 0 0 0 0 0 I Glaz U17 S23 ne 14.45 17.05 0 0 0 0 0 0 Wall ICF R19 below grade se 3.71 0.55 42 152 19 30 108 14 11 Wall R35 cavity and R10 se 2.22 0.50 42 67 15 30 47 10 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 12 173 249 9 130 187 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 Wall ICF R19 below grade sw 3.84 0.68 0 0 0 0 0 0 Wall R35 cavity and R10 sw 2.22 0.50 0 0 0 0 0 0 -Glaz U17 S23 sw 14.45 20.75 0 0 0 0 0 0 Glaz U17 S23 sw 14.45 14.53 0 0 0 0 0 0 Wall ICF R19 below grade nw 3.83 0.67 0 0 0 0 0 0 Wall R35 cavity and R10 nw 2.22 0.50 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 -Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Ceil R70 vaulted - 1.53 0.59 0 0 0 0 0 0 Flor 21 B-32t - 1.19 0.00 116 137 0 83 98 0 Flor 22D-15tpm - 25.33 0.00 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0.18 95 68 - Effect WAR WAR -- 12 Sensible Load(Btuh) ACH 0.02 9 0.02 6 0.09 Latent Load(Btuh) Internal a Occupants at 230 and 200 Btuh 1 230 200 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 625 509 452 223 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 54 E Cfm 54 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load -13 6 21 Total Load Sum lines 13 through 19 625 509 44E IE I\E D Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �� Oak Lane\309 ���^^^yyy 2Q11Nw�904280 22 ACCA .A309 O.r'9 Right-Suite®Universal 2021 21.0.07 RSU20087 rgEwiewe Page 3 _ w t�, 09 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N 09/28/2022- ASPEN FORCOMCCIMANCE 1 imp BUILDING DEPARTMENT imp ' ENERGY RIg ht-J8® Form J1 Job: 309 Oak Lane GI INNOVATIONS Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email:max@eiboulder.com Web:www.eiboulder.com 1 Name of Room Kitchen Dining 2 Running Feet of Exposed Wall 35.8 ft 30.5 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 16.1 ft 861.6 ft2 15.6 ft 718.3 ft2 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 11.0 x 24.8 ft 272.3 ft2 8.8 x 21.8 ft 190.3 ft2 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 550.9 ft2 0 ° 399.5 ft2 Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall ICF R19 below grade ne 3.73 0.57 0 0 0 0 0 0 . Wall R35 cavity and R10 ne 2.22 0.50 0 0 0 0 0 0 I Glaz U17 S23 ne 14.45 17.05 0 0 0 0 0 0 Wall ICF R19 below grade se 3.71 0.55 99 380 67 0 0 0 11 Wall R35 cavity and R10 se 2.22 0.50 270 540 121 124 276 62 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 9 130 187 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 18 260 373 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 Wall ICF R19 below grade sw 3.84 0.68 44 169 30 0 0 0 Wall R35 cavity and R10 sw 2.22 0.50 133 183 41 111 207 46 -Glaz U17 S23 sw 14.45 20.75 33 477 685 0 0 0 Glaz U17 S23 sw 14.45 14.53 18 260 262 18 260 262 Wall ICF R19 below grade nw 3.83 0.67 0 0 0 0 0 0 Wall R35 cavity and R10 nw 2.22 0.50 59 132 30 276 419 94 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 -Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 24 347 409 Glaz U17 S23 nw 14.45 17.05 0 0 0 64 925 1091 Ceil R70 vaulted - 1.53 0.59 279 428 163 209 321 123 Flor 21B-32t - 1.19 0.00 272 324 0 0 0 0 Flor 22D-15tpm - 25.33 0.00 0 0 0 190 773 0 Infiltration Heating Load(Btuh) 0.18 863 774 - Effect WAR WAR 12 Sensible Load(Btuh) ACH 0.22 81 0.20 73 0.09 Latent Load(Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 1200 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 4144 3089 4301 2880 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 54 E Cfm 54 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load -151 721 21 Total Load Sum lines 13 through 19 4144 3089 4301-. ra r Ri ,� fVEt� Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �� Oak Lane\309 ���^^^yyy 204Lt090!32Q 22 ACCA .A309 O ---- Right-Suite®Universal 2021 21.0.07 RSU20087 rgEwiewe Page 4 _ w t�, 09 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N 09/28/2022- ASPEN FORCOMCCIMANCE 1 imp BUILDING DEPARTMENT imp ' ENERGY RIg ht-J8® Form J1 Job: 309 Oak Lane GI INNOVATIONS Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email:max@eiboulder.com Web:www.eiboulder.com 1 Name of Room Bed 3 Bath 3 2 Running Feet of Exposed Wall 21.8 ft 5.5 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 8.1 ft 326.3 ft2 8.1 ft 234.3 ft2 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 11.0 x 10.8 ft 118.3 ft2 11.0 x 5.5 ft 60.5 ft2 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 12.3 ° 121.0 ft2 12.3 ° 61.9 ft2 Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall ICF R19 below grade ne 3.73 0.57 0 0 0 0 0 0 . Wall R35 cavity and R10 ne 2.22 0.50 89 198 44 0 0 0 I Glaz U17 S23 ne 14.45 17.05 0 0 0 0 0 0 Wall ICF R19 below grade se 3.71 0.55 0 0 0 0 0 0 11 Wall R35 cavity and R10 se 2.22 0.50 74 134 30 38 71 16 -Glaz U17 S23 se 14.45 20.75 0 0 0 6 87 124 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 14 202 290 0 0 0 Wall ICF R19 below grade sw 3.84 0.68 0 0 0 0 0 0 Wall R35 cavity and R10 sw 2.22 0.50 0 0 0 0 0 0 -Glaz U17 S23 sw 14.45 20.75 0 0 0 0 0 0 Glaz U17 S23 sw 14.45 14.53 0 0 0 0 0 0 Wall ICF R19 below grade nw 3.83 0.67 0 0 0 0 0 0 Wall R35 cavity and R10 nw 2.22 0.50 26 57 13 13 29 7 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 -Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Ceil R70 vaulted - 1.53 0.59 121 186 71 62 95 36 Flor 21B-32t - 1.19 0.00 0 0 0 0 0 0 Flor 22D-15tpm - 25.33 0.00 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0.18 286 77 - Effect WAR WAR 12 Sensible Load(Btuh) ACH 0.07 27 0.02 7 0.09 Latent Load(Btuh) Internal a Occupants at 230 and 200 Btuh 1 230 200 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 1064 692 360 202 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 54 E Cfm 54 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load -14 12 21 Total Load Sum lines 13 through 19 1064 692 3 E 02E I\1E D Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �� Oak Lane\309 ���^^^yyy 2Q11Nw�904280 22 ACCA .A309 O.r'9 Right-Suite®Universal 2021 21.0.07 RSU20087 rgEwiewe Page 5 _ w t�, 09 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N 09/28/2022- ASPEN FORCOMGOINUAKS 1 imp BUILDING DEPARTMENT imp ' ENERGY RIg ht-J8® Form J1 Job: 309 Oak Lane GI INNOVATIONS Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email:max@eiboulder.com Web:www.eiboulder.com 1 Name of Room Bath 2 M. Bed 2 Running Feet of Exposed Wall 5.3 ft 12.8 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 8.1 ft 230.6 ft2 8.1 ft 343.0 ft2 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 11.0 x 5.3 ft 57.8 ft2 11.0 x 12.8 ft 140.3 ft2 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 12.3 ° 59.1 ft2 12.3 ° 143.5 ft2 Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall ICF R19 below grade ne 3.73 0.57 0 0 0 0 0 0 . Wall R35 cavity and R10 ne 2.22 0.50 0 0 0 0 0 0 I Glaz U17 S23 ne 14.45 17.05 0 0 0 0 0 0 Wall ICF R19 below grade se 3.71 0.55 0 0 0 0 0 0 11 Wall R35 cavity and R10 se 2.22 0.50 36 67 15 88 169 38 -Glaz U17 S23 se 14.45 20.75 6 87 124 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 12 173 249 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 -Glaz U17 S23 se 14.45 20.75 0 0 0 0 0 0 Wall ICF R19 below grade sw 3.84 0.68 0 0 0 0 0 0 Wall R35 cavity and R10 sw 2.22 0.50 0 0 0 0 0 0 -Glaz U17 S23 sw 14.45 20.75 0 0 0 0 0 0 Glaz U17 S23 sw 14.45 14.53 0 0 0 0 0 0 Wall ICF R19 below grade nw 3.83 0.67 0 0 0 0 0 0 Wall R35 cavity and R10 nw 2.22 0.50 13 28 6 31 68 15 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 -Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Glaz U17 S23 nw 14.45 17.05 0 0 0 0 0 0 Ceil R70 vaulted - 1.53 0.59 59 91 35 144 220 84 Flor 21B-32t - 1.19 0.00 0 0 0 0 0 0 Flor 22D-15tpm - 25.33 0.00 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0.18 74 180 - Effect WAR WAR -12 Sensible Load(Btuh) ACH 0.02 7 0.05 17 0.09 Latent Load(Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 2 460 400 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 347 199 810 831 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 54 E Cfm 54 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load 12 -32 21 Total Load Sum lines 13 through 19 347 199 8103� �� ,� fVED Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �� Oak Lane\309 ���^^^yyy 2Q11Nw�904280 22 ACCA .A309 O.r'9 Right-Suite®Universal 2021 21.0.07 RSU20087 rgEwiewe Page 6 _ w t�, 09 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N 09/28/2022- ASPEN FORCOMCCIMANCE 1 imp BUILDING DEPARTMENT imp N Main Level iwq Bed 2 `4 rn LIVING BED 2 O wa BATH 1 0 I Bath 1 _ - 4 ;_ f n ILiving -{._ - N 0 BED 1 Bed 1 0 N HI. OM T W/D/Mech. vs :I II HW oN O (O 13 Ri; r,Q 0'--1/7=3'-0' r= � a- L. i I ,. ,_ .e.,, Kitchen Y 02 nu.uniGIE ® r= N Dning II MN II--`: ��V11 KI 1 CHEN -i 1 ;r_ t BENCH i MAIN LI Job #: 309 Oak Lane Energy Innovations Y Performed by Max Nuttelman for: 1e ED Hans Preiss Right-Suite®�i Universal 2021 Boulder,CO 80305 2021ot ar 01487, 22 Phone:720-281-4554 �VUf [1 V www.eiboulder.com max@eiboulder.cc ' ak Lane_Man J_2021 11 10.rup 09/28/2 22 U ASPEN 1imp N Upper Level o��� I I g BED 3 �' - JJ SBed 3 I cp I I 1 �-' OPEN TO BELOW I s ` e 1 N L01 BATH 3 ro 1 Bath 3 I I - in 1. Open Living - W11 - �A(-e IiN - - Bath 2 I I = I BA1H2 O I (N M 1 M BED M.Bed N rI: 0 11 _ 'i 1 I 6 1 1 I \ emm�uu i-- - ,111 " 1 1 1 11 { iiii Y OPEN TO BELO\A' IA Open Kitchen Ir Ih Open Dining 2:12 1 it 1 II lit rt UPPI 6 Job #: 309 Oak Lane Energy Innovations IVED Performed by Max Nuttelman for: Hans Preiss Right-Suite®Universal 2021 Boulder,CO 80305 VIrr10 _ 0 Phone:720 281 4554 221-NfoM1Ig2DMA Z 022EWJEIak Lane Man J_2021-11-10.rupwww.eiboulder.com max@eiboulder.co EVAI °9/28/2 22 ASPEN ` � limp BUILDING DEPAR I MELT EENERGY Manual S Compliance iance Report Job: 309 Oak Lane p p I INNOVATIONS Date: Nov 10,2021 Entire House By: Max Nuttelman Energy Innovations Boulder,CO 80305 Phone:720-281-4554 Email: max@a eiboulder.com Web:www.eiboulder.com Project Information For: Hans Preiss, Bright Sense Cooling Equipment Design Conditions Outdoor design DB: 91.0°F Sensible gain: 13518 Btuh Entering coil DB: 75.0°F Outdoor design WB: 59.0°F Latent gain: 0 Btuh Entering coil WB: 60.8°F Indoor design DB: 75.0°F Total gain: 13518 Btuh Indoor RH: 50% Estimated airflow: 820 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Pkg ASHP Manufacturer: Arctic Model: HP-035ZA/BE Actual airflow: 820 cfm Sensible capacity: 20591 Btuh 152% of load Latent capacity: 3634 Btuh 0% of load Total capacity: 24225 Btuh 179% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: -15°F Heat loss: 21056 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Pkg ASHP Manufacturer: Arctic Model: HP-035ZA/BE Actual airflow: 820 cfm Output capacity: 28320 Btuh 135% of load Capacity balance: 0 °F Supplemental heat required: 0 Btuh Economic balance: 0 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 820 cfm Output capacity: 7.7 kW 124% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. wrightsoft- RECEIVED =om,^, Right-Suite®Universal 2021 21.0.07 RSU20087 Page 1 ACCP. ...\309 Oak Lane\309 Oak Lane_Man J_2021-11-10.rup Calc=MJ8 faces: N 01/1 9/2 0 2 2 REVIEWIE-09/28/2022 11 ASPEN ` `o0camwea imp BUILDING DEPARTMENT