Loading...
HomeMy WebLinkAboutFile Documents.309 Oak Ln.0021-2022-BRES (19) e e rn e n t ENVIRONMENTAL INC 189 County Rd. 135 Glenwood Springs,CO 81601 josh@elementconsults.com (970) 274-3139 Property Address Asbestos Sampling Report 309 Oak Lane Date: 11/19/2021 Aspen, CO 81611 +' UPDATED 12/23/2021 3 Date of Inspection: 11/17/2021 Element Environmental Project#: u SH Built 111721 Oak cu Date of 2nd Inspection: 12/15/21 E (1) Client: Client Job Name Oak Lane SH Built 314 AABC Suite B Aspen, CO 81611 TABLE OF CONTENTS Attn: 1.0 -Scope of Work 2.0 -Sampling Requirements Tom Sherlock O 3.0 -Sampling Methodology 4.0 - Laboratory 5.0 -Suspect Materials Sampled 6.0 -Table of Results 7.0 - Description of Sampling Area Building Inspector: 8.0 -Conclusion Ellen Johnson 9.0 - Lab Report 10.0 -Certificates CDPHE #23799 Joshua Johnson Asbestos Samples Analyzed: 24 Positive Asbestos Samples: 2 CDPHE #18401 N O REC ,a E D N ca ll � 01/19/2022 ' O9,26,2022 FaRcoutakeuma` ASPEN BUILDING DEPARTMENT 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a complete demolition. Element Environmental conducted an inspection for materials that would be impacted during the demolition. This inspection was a full inspection for demolition of the mobile home and shed. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos.. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: -Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.-5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2-Miscellaneous materials- Minimum of 2 samples 2.3-Thermal Systems Insulation(TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The friable materials are segregated into separate homogenous areas. The size of the sampling area is determined. Samples are taken according to a random numerical sequence of the subareas, following guidelines per the EPA Pink Book: Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials. 4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 23799, performed the inspection. The findings were reviewed by Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or<1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional "point count" performed to be considered less than 1% and not be regulated by the CDPHE. The lab's documents with analyses and findings are found below RECEIVED 22 e e m e n t 189 county rd 135 glenwooci(�( ��7� `�E i6o1 970.274 3139 www.elementconsults.cors>t,n l°` ENVIRONMENTAL INC Project#-SH Built 121521 Oak LEAD ASBESTOSf S 161[11-MENT 5.0- SUSPECT MATERIALS SAMPLES • Texture • Roofing Layers • Drywall System • Joint Compound • Tape • Carpet and Pad • Tile Grout • Sheet Vinyl 6.0- TABLE OF RESULTS HOMOGENOUS DESCRIPTION OF AREA ACM CATEGORY NUMBER PPROXIMATE ACM ASSESSMENT CATEGORIES! %AND TYPE OF AREA OF SQ.FT.* ASBESTOS FOUND SAMPLES (A) Skip Trowel Texture throughout Surfacing 7 —2,500 sq.ft. Friable Non-ACM No Asbestos Detected (B) Drywall System throughout Miscellaneous 3 —2,500sq.ft. Friable Non-ACM No Asbestos Detected (C) Carpet in Living Room and Dining Miscellaneous 2 —300sq.ft. Non-Friable Non-ACM No Asbestos Detected Room (D) Carpet Pad in Living Room and Miscellaneous 2 —300 sq.ft. Non-Friable Non-ACM No Asbestos Detected Dining Room (E) Caulk on Exterior Siding Miscellaneous 2 —40 sq.ft. Non-Friable Non-ACM No Asbestos Detected (F) Sheet Vinyl under carpet and Miscellaneous 2 —300sq.ft. No.5—Friable ACM with potential for 25%-Chrysotile in 2 of 2 kitchen cork floor damage Samples (G) Tile Grout in Master Bath Miscellaneous 2 —200 sq.ft. Friable Non-ACM No Asbestos Detected (H) Shingle Layers on roof Miscellaneous 2 —1,500sq.ft. Non-Friable Non-ACM No Asbestos Detected (I) Vinyl found under the ceramic Miscellaneous 2 '200sq.ft. Friable Non-ACM No Asbestos Detected tile in Master Bath Key: ACM Assessment Categories: 1-Damaged or significantly damaged Thermal Systems Insulation 6-ACM with potential for significant damage (TSI)ACM 7-Friable ACM with low potential for damage 2-Damaged friable surfacing ACM Other-ACM not classified in the above Assessment Categories 3-Significantly damaged friable Surfacing ACM N/A-Not Applicable 4-Damaged or significantly damaged friable Miscellaneous ACM 5-ACM with potential for damage *Square footage is estimated and not for bidding purRE(E I\E 0 e. ' 22 e 1 e m en t 189 county rd 135 glenwood��)Rh d 1601 970.274.3139 tft www.elementconsults cor: ENVIRONMENTAL Project#-SH Built 121521 Oak 'b LEAD ASBESTOS S tbiNf "1[1-MENT 4 7.0- DESCRIPTION OF SAMPLING AREA The materials that were sampled for demolition include the following: • Skip Trowel Texture throughout the mobile home • Drywall System throughout the mobile home • Carpet and Pad • Caulk on the exterior siding • Sheet Vinyl that was found under the carpet in the dining room and under the kitchen cork floor • Tile Grout in the master bathroom • Roofing Layers (12/15/21) • Vinyl found under the ceramic tile in Master Bath (12/15/21) A visual inspection of the small metal shed in the back yard was performed and no suspect ACM materials were found. e e rn e n t 189 county rd 135 glenwood springs,co 81€ _7 .27Z 3 ED wwwelementconsultscom Project#-SH Built 121521 Oak ENVIRONMENTAL Y LEAD ASBESTOS HAZ 0 o �lUt1 u`�/ 0 u22 1t 09/26/2022 12) FORO011tEXAKIMACE ASPEN BUILDING DEPARTMENT 5 Sampling Locations Nt • 47 1 t3 iAZ ; 1 1 4 Era\ Lei •� _ . D. c2 h� ----1i p i C I ID --_ Al NTS e e m e n t 189 county rd 135 glenwood springs,co 81€ -7 ,.27c www.etementconsuLts.com Ls� Project#-SH Built 121521 Oak ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 0 nIr+av �nf' ui/i � u22 Y N09/26/2022 FORCOOtWiltINICEASPEN BUILDING DEPARTMENT 6 8.0- CONCLUSION The areas on the Table of Results in Black did not contain asbestos. The areas on the Table of Results in Red contains asbestos: • The Sheet Vinyl under the kitchen cork flooring and extending approximately 2 feet into the dining area under the carpet. These materials become friable when they are removed. If these materials are to be disturbed or removed,the materials MUST be remediated in accordance with the CDPHE Regulation No. 8 by a licensed abatement contractor. For residential projects over 32 square feet of surfacing material, 50 linear feet of pipe insulation,or 55 gallon drum of waste;and for commercial projects with 160 square feet of surfacing material, 260 linear feet of pipe insulation, or a 55 gallon drum of waste,a permit is required.The permit is through the CDPHE.Along with the permit, a final air clearance is required by a certified Air Monitoring Specialist. For projects over 3,000 square feet, a Project Design and Project Manager is required. Element Environmental is certified and can perform Final Clearances, Project Design,and Project Management if required.All work performed MUST follow all EPA,State Regulation 8, and OSHA regulations to protect the general public,the client, and the workers. Sincerely, Ellen Johnson e e rn e n t 189 county rd 135 glenwood springs,co 81€" '.27z:13 ED www.elementconsults.com Project#-SH Built 121521 Oak ENVIRONMENTAL Y LEAD ASBESTOS HAZ 0 0 u22 A*: ,Lit ui/i � 0,09/26/2022 Y FORCOOkCaMaASPEN BUILDING DEPARTMENT 7 9.0- LAB REPORT tiff eurofins CEI ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for Element Environmental LLC CLIENT PROJECT: SH Built 111721 Oak LAB CODE: B2111747 TEST METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORT DATE: 11/19/21 TOTAL SAMPLES ANALYZED: 20 #SAMPLES>1%ASBESTOS: 2 e e rn en t 189 county rd 135 glenwood springs,co 81€„ _7 .27c 7:3 E www.elementconsults.com 1•w Project#-SH Built 121521 Oak ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 0 o NEW 1 U /1 622 1t 09/26/2022 ij FORO011tEXAKIMACE` ASPEN BUILDING DEPARTMENT 8 • eurofins Asbestos Report Summary ti By: POLARIZING LIGHT MICROSCOPY CEI PROJECT: SH Built 111721 Oak LAB CODE: B2111747 METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 ASBESTOS Client ID Layer Lab ID Color Sample Description 309-Al B188520 White Skip Trowel None Detected 309-A2 B188521 White Skip Trowel None Detected 309-A3 B188522 White Skip Trowel None Detected 309-A4 B188523 White Skip Trowel None Detected 309-A5 B188524 White Skip Trowel None Detected 309-A6 B188525 White Skip Trowel None Detected 309-A7 B188526 White Skip Trowel None Detected 309-61 Layer 1 B188527 White Joint Compound None Detected Layer 2 B188527 White,Tan Drywall None Detected 309-B2 Layer 1 B188528 White Joint Compound None Detected Layer 2 B188528 White,Tan Drywall None Detected 309-B3 Layer 1 B188529 White Joint Compound None Detected Layer 2 B188529 WhiteTan Drywall None Detected 309-C1 B188530 Beige Carpet None Detected 309-C2 B188531 Beige Carpet None Detected 309-D1 B188532 Green,Yellow Carpet Pad None Detected 309-D2 B188533 Green,Yellow Carpet Pad None Detected 309-El B188534 Gray Caulking None Detected 309-E2 B188535 Gray Caulking None Detected 309-F1 B188536 White Sheet Vinyl Chrysotile 25% 309-F2 B188537 White Sheet Vinyl — Chrysotile 25% 309-G1 B188538 Black Grout None Detected 309-G2 B188539 Black Grout None Detected Page 1 of 1 e e rn e n t 189 county rd 135 glenwood springs,co 81€ _7 .27c 3 l Eii E www.etementconsuLts.com 1s••w� Project#-SH Built 121521 Oak ENVIRONMENTAL +l" LEAD ASBESTOS HAZ 0�1Ul � u`i/i0 i u 2 2 3I It 09/26/2022 ij FOROODLEXAKIJANCEASPEN BUILDING DEPARTMENT 9 tiff° eurofins ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY CE I Client: Element Environmental LLC Lab Code: B2111747 189 CR 135 Date Received: 11-18-21 Glenwood Springs, CO 81601 Date Analyzed: 11-19-21 Date Reported: 11-19-21 Project: SH Built 111721 Oak ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous 309-Al Skip Trowel Heterogeneous 60% Binder None Detected B188520 White 35% Calc Carb Non-fibrous 5% Paint Bound 309-A2 Skip Trowel Heterogeneous 60% Binder None Detected B188521 White 35% Calc Carb Non-fibrous 5% Paint Bound 309-A3 Skip Trowel Heterogeneous 60% Binder None Detected B188522 White 35% Calc Carb Non-fibrous 5% Paint Bound 309-A4 Skip Trowel Heterogeneous 60% Binder None Detected B188523 White 35% Calc Carb Non-fibrous 5% Paint Bound 309-A5 Skip Trowel Heterogeneous 60% Binder None Detected B188524 White 35% Calc Carb Non-fibrous 5% Paint Bound 309-A6 Skip Trowel Heterogeneous 60% Binder None Detected B188525 White 35% Calc Carb Non-fibrous 5% Paint Bound 309-A7 Skip Trowel Heterogeneous 60% Binder None Detected B188526 White 35% Calc Carb Non-fibrous 5% Paint Bound Page 1 of 5 e e rn en t 189 county rd 135 genwood springs,co 81€,^ ,.27c 7:3 I ED www.etementconsults.com Project#-SH Built 121521 Oak ENVIRONMENTAL INC LEAD ASBESTOS HAZ��/10 0 22 I;EVUr+vim � � it09/26/2022 9 FORCOOMUMICEASPEN BUILDING DEPARTMENT 10 eurofins ASBESTOS BULK ANALYSIS ti• By:POLARIZING LIGHT MICROSCOPY CE I Client: Element Environmental LLC Lab Code: B2111747 189 CR 135 Date Received: 11-18-21 Glenwood Springs,CO 81601 Date Analyzed: 11-19-21 Date Reported: 11-19-21 Project: SH Built 111721 Oak ASBESTOS BULK PLM,EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous 309-B1 Joint Compound Heterogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb B188527 Non-fibrous 5% Paint Bound Layer 2 Drywall Heterogeneous 20% Cellulose 75% Gypsum None Detected B188527 White,Tan 5% Fiberglass Fibrous Bound 309-B2 Joint Compound Heterogeneous 60% Binder None Detected Layer 1 Mite 35% Calc Carb B188528 Non-fibrous 5% Paint Bound Layer 2 Drywall Heterogeneous 20% Cellulose 75% Gypsum None Detected B188528 White,Tan 5% Fiberglass Fibrous Bound 309-B3 Joint Compound Heterogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb B188529 Non-fibrous 5% Paint Bound Layer 2 Drywall Heterogeneous 20% Cellulose 75% Gypsum None Detected B188529 White,Tan 5% Fiberglass Fibrous Bound 309-C1 Carpet Heterogeneous 85% Synthetic Fiber 15% Binder None Detected B188530 Beige Fibrous Loosely Bound Page 2 of 5 e e rn e n t 189 county rd 135 glenwood springs,co 81€,^ ,.27c '3 I www.etementconsuLts.com 66cc�� Project#-SH Built 121521 Oak ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 0 I;EVUr+vim u�/i i u22 it09/26/2022 FORCOOMUMICEASPEN BUILDING DEPARTMENT 11 . eurofins • ASBESTOS BULK ANALYSIS ti By: POLARIZING LIGHT MICROSCOPY CE I Client: Element Environmental LLC Lab Code: B2111747 189 CR 135 Date Received: 11-18-21 Glenwood Springs, CO 81601 Date Analyzed: 11-19-21 Date Reported: 11-19-21 Project: SH Built 111721 Oak ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous 309-C2 Carpet Heterogeneous 85% Synthetic Fiber 15% Binder None Detected B 188531 Beige Fibrous Loosely Bound 309-D1 Carpet Pad Heterogeneous 100% Foam None Detected B 188532 Green,Yellow Non-fibrous Bound 309-D2 Carpet Pad Heterogeneous 100% Foam None Detected B188533 Green,Yellow Non-fibrous Bound 309-E1 Caulking Homogeneous 100% Caulk None Detected B188534 Gray Non-fibrous Bound 309-E2 Caulking Homogeneous 100% Caulk None Detected B188535 Gray Non-fibrous Bound 309-F1 Sheet Vinyl Heterogeneous 25% Cellulose 50% Vinyl 25%Chrysotile B188536 White Fibrous Bound 309-F2 Sheet Vinyl Heterogeneous 25% Cellulose 50% Vinyl 25%Chrysotile B188537 White Fibrous Bound Page 3 of 5 e e rn en t 189 county rd 135 genwood springs,co 81€ -7 ,.27c:13 1 E ID www.etementconsuLts.com 1•� Project#-SH Built 121521 Oak ENVIRONMENTAL .: LEAD ASBESTOS HAZtyli/ 0 nEV Ir+av �n � 0�22 0,09/26/2022 Y FORCOOMUMICEASPEN BUILDING DEPARTMENT 12 . eurofins • ASBESTOS BULK ANALYSIS ti By: POLARIZING LIGHT MICROSCOPY CE I Client: Element Environmental LLC Lab Code: B2111747 189 CR 135 Date Received: 11-18-21 Glenwood Springs, CO 81601 Date Analyzed: 11-19-21 Date Reported: 11-19-21 Project: SH Built 111721 Oak ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous 309-G1 Grout Homogeneous 65% Silicates None Detected B188538 Black 35% Binder Fibrous Tightly Bound 309-G2 Grout Homogeneous 65% Silicates None Detected B188539 Black 35% Binder Fibrous Tightly Bound Page 4 of 5 e e rn en t 189 county rd 135 genwood springs,co 81€ -7 ,.27c:13 1 • D www.etementconsuLts.com 1.•�� Project#-SH Built 121521 Oak ENVIRONMENTAL AlLEAD ASBESTOS HAZtyli/ �0 0 nEV Ir+av �n o22 0,09/26/2022 Y FORCOOMUMICEASPEN BUILDING DEPARTMENT 13 eurofins CEI LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb =Calcium Carbonate METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORTING LIMIT: <1%by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points REGULATORY LIMIT: >1%by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID and sample description. ANALYST: j atL APPROVED BY: lG ✓ Gl/�' Regan ems Tianbao Bai,Ph.D.,CIH Laboratory Director f Scott Minyard NVLA ° TESTING NVLAP LAB CODE 101768-0 Page 5of5 e e rn en t 189 county rd 135 glenwood springs,co 81€ -7 ,.27z 13 1 E D www.etementconsuLts.com 1•� Project#-SH Built 121521 Oak ENVIRONMENTAL YC LEAD ASBESTOS HAZ 0 n Ir+av �nf' ui/i0 i u22 Y it09/26/2022 FORCOMWINUNICEASPEN BUILDING DEPARTMENT 14 ASBESTOS �- SAMPLING FORM CE ' LASS COMPANY CONTACT INFORMATION Company:Element Environmental Job Contact:Josh Johnson Project Name: -5N s to 1 I F 10,)I Oa k Project ID#: Tel:970-274-3139 SAMPLE ID# DESCRIPTION/LOCATION / TE &NG\ 5�,0 1�O�ll-e I Llvl>ZC� CNI(ilia PLM II TEMI I 1 �•c sctr PLM LJ TEMI I ?� r- A f� '�k"i 4Vq PLM L .J TEMI I A A innTt HQ'IW111111 I I TEMI—I U. U �r.cc,,Fi ►a t-(/l PLM I I TEM1-1 } �"�A,lrli Li PLM I ( TEMI I "k I t' •(t•oi PLM I j TEMI— I .0.f well 4 !-/-v^[t! I j TEMI--I tk. I�I. -itb f.6 LIP/l./ PLM I ( TEMI I P I' 4 Ha/l rPI(iQ( LM I . I TEMI I i l.l?1V` l� L .tllul ----PLM I._tJ TEMI I /� •I �� t PLM I f TEM(Str).-, '1 1' (�C i- .P4 a t- t I/1 a , PLM I TEMI I f0 I I A PLM T[MI—I E= C all I,(1; E.X4 . 1'(yis An, 4' SLJ4 I 1 TEMI I M1 I. It , 'l/ r I J ' TEMI • 1 5t\P�k- U n l u,,cipic cp JPLM I I TEMI 1 , ,l q "• / ; PLM I V TEMI j TiI� Q�fri(,( t` /4,54fenLh!<GCJI�` ' 1-- -ITEMI I G-� , v t1 Ic t , 6)4// PLM I tl TEMI I V PLM I 1 TEMI PLM I I TEMI— I PLM I-1 TEM( 1 PLM I I TEMI I PLM [77 TEMI I PLM I I TEMI .( PLM I I TEM( I PLM I ( TEM I— I Page of VERSION CCOC.0215.2I2.LD Custome'CDC Page 2 e e m e n t 189 county rd 135 glenwood springs,co 81E -7 ..272:13 1 www.elementconsults.com Project#-SH Built 121521 Oak ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 0 nr Urta,Lnf' ��/ � �22 09/26/2022 Y FOROJoicatFUNICE ASPEN BUILDING DEPARTMENT 15 eurofins ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for Element Environmental LLC CLIENT PROJECT: SH Built 121521 Oak LAB CODE: B2113648 TEST METHOD: EPA 600/R93/ 116 and EPA 600/M4-82/020 REPORT DATE: 12/17/21 TOTAL SAMPLES ANALYZED: 4 #SAMPLES>1% ASBESTOS: 730 SE Maynard Road •Cary, NC 27511 •919.481.1413 e e rn en t189 county rd 135 glenwood springs,co 81€ 72 7 ,.27L 213) E Dwww.elementconsults.com �`/ Project#-SH Built 121521 Oak ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 0 o NEW 1 U /1 622 1t 09/26/2022 12) FORO011tEXAKIMACE` ASPEN BUILDING DEPARTMENT 16 • eurofins Asbestos Report Summary ti By: POLARIZING LIGHT MICROSCOPY PROJECT: SH Built 121521 Oak LAB CODE: B2113648 METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 ASBESTOS Client ID Layer Lab ID Color Sample Description 309 H1 Layer 1 B218326 Brown,Black Shingle None Detected Layer 1 B218326 Black,Brown Shingle None Detected 309 H2 Layer 1 B218327 Brown,Black Shingle None Detected Layer 1 B218327 Black,Brown Shingle None Detected 30911 B218328 White,Gray Sheet Vinyl None Detected 309 12 B218329 White,Gray Sheet Vinyl None Detected 730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 1 of 1 e e rn e n t 189 county rd 135 glenwood springs,co 81€ _7 .27c::,.13 I rEii ID www.etementconsuLts.com 1s••w� Project#-SH Built 121521 Oak ENVIRONMENTAL li LEAD ASBESTOS HAZ 0 e't 'p u`i/i0 u22 3En It 09/26/2022 ij cmcaicwpwrrra ASPEN BUILDING DEPARTMENT 17 tiff® eurof.ins ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY CEI Client: Element Environmental LLC Lab Code: B2113648 189 CR 135 Date Received: 12-16-21 Glenwood Springs, CO 81601 Date Analyzed: 12-17-21 Date Reported: 12-17-21 Project: SH Built 121521 Oak ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous °h 309 HI Shingle Heterogeneous 20% Fiberglass 45% Tar None Detected Layer 1 Brown,Black 35% Silicates B218326 Fibrous Bound Layer 1 Shingle Heterogeneous 20% Fiberglass 45% Tar None Detected B218326 Black,Brown 35% Silicates Fibrous Bound 309 H2 Shingle Heterogeneous 20% Fiberglass 45% Tar None Detected Layer 1 Brown,Black 35% Silicates B218327 Fibrous Bound Layer 1 Shingle Heterogeneous 20% Fiberglass 45% Tar None Detected B218327 Black,Brown 35% Silicates Fibrous Bound 309 11 Sheet Vinyl Heterogeneous 60% Binder None Detected B218328 White,Gray 40% Silicates Non-fibrous Bound 309 12 Sheet Vinyl Heterogeneous 60% Binder None Detected B218329 White,Gray 40% Silicates Non-fibrous Bound 730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 1 of 2 e e rn en t 189 county rd 135 genwood springs,co 81€,^ ,.27z 7:3 I Eii D www.etementconsuLts.com L.�w Project#-SH Built 121521 Oak ENVIRONMENTAL WC LEAD ASBESTOS HAZ 00 I;EVUr+vim ��/1 � �22 0,09/26/2022 E FORCOOMUMICEASPEN BUILDING DEPARTMENT 18 ti$: eurofins CEI LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb =Calcium Carbonate METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORTING LIMIT: <1%by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points REGULATORY LIMIT: >1%by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID and sample description. ANALYST: 4 �/ APPROVED BY: ,;•• Greg Ru Tianbao Bai,Ph.D.,CIH Laboratory Director NVEA TESTING NVLAP LAB CODE 101768-0 730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 2 of 2 e e rn en t 189 county rd 135 glenwood springs,co 81€ -2 7 ,.27z 13 I E D www.etementconsuLts.com 1•� Project#-SH Built 121521 Oak ENVIRONMENTAL Y LEAD ASBESTOS HAZ 0 0 Lift*: Y�nf' �� �� 2 2 it09/26/2022 FORCOMWINUNICEASPEN BUILDING DEPARTMENT 19 ASBESTOS r(". SAMPLING FORM CE ' LABS COMPANY CONTACT INFORMATION Company:Element Environmental Job Contact:Josh Johnson Project Name:. 14.3u,JiL I ts.,.?1 Q(& Project ID#: Tel:970-274-3139 • 1 SAMPLE ID# DESCRIPTION/LOCATION TE 3n 1 I 5hirvic k L rs a,(,) PLM J TEMI 1 / PLM _ TEMI I 5i-eP� V/ l I A1I45+ /TOPLM \�I TEMI I �a I� n 1, PLM I TEMI—I PLM I ) TEMI I • PLM (---J TEMI I PLM I I TEMI I PLM I J TEMI— I PLM I I TEMI I PLM I I TEMI-1 PLM I I TEMI I PLM L J TEMI I PLM I J TEML__J PLM I ] TEMI I PLM I 1 TEMI I PLM I TEMI I PLM I J TEM[] PLM I I TEM fl PLM I I TEM fl PLM I I TEMI I PLM I I TEM( 1 PLM I TEMI I PLM E1 TEMI I PLM rI TEM I-1 PLM I J TEM r—J PLM I 1 TEMI PLM 1 ] TEMI I PLM I I TEMI—I Page of VERSION CCOC.0215.2I2.LO Custome•COC Page 2 e e m e n t 189 county rd 135 glenwood springs,co 81E -7 ,.27z www.etementconsuLts.com L� Project#-SH Built 121521 Oak ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 0�22 nEv Ir+av �n ��/ � it 09/26/2022 Y FORM GOVFLINICE ASPEN BUILDING DEPARTMENT 20 10.0- CERTIFICATES r , r �r 9 cr >a z .. � x } ; 4p fi Y ,„. s v 2 ^` I Department � " - .# �Coloradoue a ment s ofPublic Health I of Public Health a �ue. and Environment ? and Environment ' , i �' ASBESTOS ASBESTOS l, ` �le �;i CERTIFICATION* �',ter-, _ ,' CERTIFICATION* 4 -� This certifies that �' P'ti This certifies that - w ' Ellen JohnsonLt Joshua Jay Johnsoniri''''':) �I Certification No.:1g401 , �. Certification\o.:20797 4 -' x,, has t therequtrements of25 7 507,C.R 5 and Air Quality Control i has met the requirements of 25 7-507,C.R.S.and Air Quality C tr I ZA.` Commission Regulation No 8,Pan B,and is hereby certified by the —�' �^ - commission Regulation No 8,Part B,and is booby certified by the state tit Colorado in the following discipline: � F state of Colorado in the following discipline. '� `� Building Inspector* a ;� Building Inspector* .. � , £ " �� e `r� ' Iss ed: hum 29,2021 0 Issued: August 09,2021 I / Expires: August09,2022 .a' ,� 4 pies: .lulu 19,2022 �.' 1,: i, *74 igk as Li .,,..J+ .1 „. i,� ' ,. rJ C { 1. fi Iti a•,tyb ins Aa hA. &a a ...„,, .,,. ._.,...,,: SEAL �t IC thS","M,'4,p `S3,i fa•s,Oor a ."'irSlik V' oV 4 t► 4'.. ♦. Y �tc4 :y J c tit;°1 4 iY r 8i0j �Z p�`I' ¢ i.'f t '¢�0' z t;i' "i''� AP. ' K: v: n�, , EJIPN� x�y4 Jvwf ;^,it,6�c at,? �Gre.,?. r3 ee! Y't�Y4�4 ay ` -t,,ett Colorado Department f PubbaHalth I and Environment ASBESTOS CONSULTING FIRM This certifies that Element Environmental LLC fRegistration No.:ACF-21640 _ has met the registration requirements of 25 7 507,C.R.S.and the Air Quality Control :- Commission Regulauon No.8,Pert B,and ie hereby euMoriord to Oviform asbestos consulting activities as required under Regulation No 8,Part B,in the stets of Colorado. S LoperIssued. January 25,2022 - — xumnnaa Ivcpira: January 25,2022 u¢o newe.eww. aaai e e m e n 1.8g county rd 135 glenwood springs,co 81€ =7 .27c ci3 l D www.elementconsutts.com Project#-SH Built 121521 Oak ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 o VAJE 1 u`�/ 0 u 2 2 It 09/26/2022 FOR ASPEN BUILDING DEPARTMENT