HomeMy WebLinkAboutFile Documents.309 Oak Ln.0021-2022-BRES (20) shñpe
ARCHITECTURE
July 8th, 2022
Re: 0021-2022-BRES_309 OAK LN_BuildingComments_1
Dear City of Aspen Plans Examiner Emmy Garrigus,
Please consider our responses below and associated attachments to the Zoning Review
Comments received on Friday June 21th, 2022.
1. State license to demolish required prior to permit issuance.
SH Built is in the process of obtaining a required State license to demolish sheet vinyl
under carpet and kitchen cork floor prior to permit issuance.
2. Show all of these penetrations on your roof plan and elevations in your architectural set..
Please see updated roof plan on sheet A103 and elevation sheets A201 & A202 for all
penetration information.
3. Submit an updated version of this entire form complete with affidavit#1 and #2 including
signatures and notarization. Please also complete all spaces on page 2 of the submitted
application. The form can be found on...
Please see updated version of this form complete with Affidavit#1 and #2 including
signatures and notarization. Please also see completed page 2 of the application.
4. Per AF103.10 an accessible clear space 24" in diameter by 3' in height adjacent to the
vent pipe shall be provided at the anticipated location of a future radon fan. How will this
be accomplished?
Please see updated sheet A101 for dashed line indicating location of potential future
radon fan.
RECEIVED
07/28/2022
ASPEN
BUILDING DEPARTMENT
5. Show plumbing pipe penetration(s) and label height of termination as not less than 12"
above the roof per IPC 903.1/COA Title 8. Label all other penetrations as shown in
mechanical document.
Please see updated roof plan A103 for penetration information.
6. Show penetration of radon mitigation stack pipe as shown on A011 and A102.
Please see updated sheet A103 for location of radon mitigation stack pipe. Also shown
on elevations on A202.
7. EV charging capabilities required per COA Ord 40, 2016.
Please see updated Main Level Reflected Ceiling Plan on A104 showing the location of
a proposed raceway to facilitate future installation and use of an electric vehicle charger.
8. Electrical panel requires 30x36x78" clearance per NEC 110.26. Either move the panel or
move the hot water heater.
Please see updated sheet A104, electrical panel has been relocated to provide
clearance.
9. What is this? Please label.
This was a drawing error and has been deleted. Please see updated sheet A201.
10. What is this? Please label.
This was a drawing error and has been deleted. Please see updated sheet A201.
11. Remedy this broken image.
This was a drawing error and has been fixed. Please see updated sheet A302 for
corrected image.
12. Provide a detail of this area where the wall transitions from framing to concrete. Show
insulation values per R402.1.2, air barrier details, and thermal envelope continuity.
Please see updated sheet A501 for new detail of wall transitioning from framing to
concrete. Please see sheet A302 for envelope continuity outline.
RECEIVED
07/28/2022
ASPEN
BUILDING DEPARTMENT
13. Provide a detail of slab on grade insulation for floor assemblies.
Please see updated sheet A501 for new detail of slab on grade insulation.
Sincerely, J�o�Pp0 LICk4iittf
� �GAN 4\ `sc. t/,
Morgan Law •.?/i4/
404362
Principal Architect, CPHC •,�'
Morgan@shapearchitect.com
RECEIVED
07/28/2022
ASPEN
BUILDING DEPARTMENT