Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.366 Pfister Dr.0048-2021-BRES (4)
Installation & Maintenance Manual mOnTIGO® i the art of fireplaces Del Ray INDOOR DIRECT VENT GAS FIREPLACE DRL3613NI 16,000 BTU/hr Natural Gas or Propane Gas DRL3613NI-2 16,000 BTU/hr Natural Gas or Propane Gas DRL4813NI 21,000 BTU NG/19,000 BTU Propane/hr DRL4813NI-2 21,000 BTU NG/19,000 BTU Propane/hr DESIGN ACAUTION EEI:: Installation and service must be performed by a qualified installer, service agency or the gas fitter.Check local codes and read all CERTIFIES) C US instructions prior to installation. • A WARNING: FIRE OR EXPLOSION HAZARD Canada Failure to follow safety warnings exactly could result in serious injury, death,or property damage. 'Do not store or use gasoline or other flammable vapors and ENER U 1 DE liquids in the vicinity of this or any other appliance. —WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. Look for the EnerGuide • Do not touch any electrical switch;do not use any Gas Fireplace Energy phone in your building. Efficiency Rating in this brochure • Leave the building immediately. • Immediately call your gas supplier from a neighbour's Based on CSA P.4.1-15 phone.Follow the gas supplier's instructions. • If you cannot reach your gas supplier,call the fire department. —Installation and service must be performed by a qualified installer,service agency or the gas fitter. NOTICE áI ' ANGER Installer:Leave this manual with the appliance.Please refer to the Montigo website for the most current version of the fireplace manual Consumer:Retain this manual for future reference.Please refer to the HOT GLASS WILL CAUSE BURNS. Montigo website for the most current version of the fireplace manual DO NOT TOUCH GLASS UNTIL rig COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. a WARNING A barrier designed to reduce the risk of burns from the hot viewing glass is provided with thisD Some materials used in the manufacturing proces• . 1 i appliance and must be installed for the protection expose you to Benzene which is known in the Sta e o alif'ornia to of children and other at-risk individuals. cause cancer and birth defects or other reproductive harm.For more information go to www.P65warnings.ca.®v3/2 4/2 $21 • . � NN XQQab,i6 �12220 BUILDING DEPARTMENT General Safety Alert Key Efficiency ADANGER A WARNING Efficiency listing Indicates a hazardous situation which,if Indicates a hazardous situation which,if not w ,— v not avoided,WILL result in death or serious avoided,COULD result in death or serious 0 '0 injury or property damage. injury or property damage. 2 a w DRL3613NI 71 A CAUTION NOTICE DRL3613LI 71 DR3613NI-2 71 Indicates a hazardous situation which,if not Indicates practices that are important,but DR3613LI-2 71 avoided,WILL result in minor or moderate not related to personal injury. injury. D RL4813N I 63 DRL4813LI 60 DR4813NI-2 63 Introduction DR4813LI-2 60 Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience,Montigo is committed to providing BTU Listing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest U safety, reliability and engineering standards. (7) a m We strongly encourage you to read and carefully follow the Ln instructions laid out in this Installation,Operation and Maintenance w Z o 0 Manual and retain it for your future reference.Pay special attention 0ro v o E to all cautions, warnings, and notices throughout this manual o v ao ao intended to ensure your safety. LU a to Q This manual covers installation,operation and maintenance.Lighting, D D v vi w w operation and care of this fireplace can be easily performed by the g z m • l7 v~ v~ homeowner. All installation and service work should be performed by a qualified or licensed installer, plumber or gas fitter as certified DRL3613NI X 16,000 X X by the state, province, region or governing body where the fireplace DRL3613LI X 16,000 is being installed. x X This installation,operation and maintenance manual is applicable DR3613NI-2 X 16,000 x X to the models described in Table 1. Refer to your rating plate to DR3613LI-2 X 16,000 verify included options. X X DRL4813NI X 21,000 X X Warranty and Installation Information:(See Appendix B) DRL4813LI X 19,000 X X The Montigo warranty will be voided by,and Montigo disclaims any DR4813NI-2 X 21,000 x X responsibility for,the following actions: • Modification of the fireplace and/or components including Direct- DR4813LI-2 X 19,000 X X Vent assembly or glass doors. Figure 1 DR and DR Builders Specifications • Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system. • Installation other than as instructed in this manual. A CAUTION • Consult your local Gas Inspection Branch on installation requirements for factory-built gas fireplaces.Installation&repairs Young children should be carefully supervised when they are in the should be done by a qualified contractor. same room as the appliance.Toddlers,young children,and others may be susceptible to accidental contact burns. • •. I r recommended if there are at-risk individuals in th n'. . o rFrlrD' access to a fireplace or stove,install an adjustable a - : (Ft 'p toddlers,young children,and other at-risk individuals out of the room and away from hot surfaces 03/24/2121 2 db3teM220 BUILDING DEPARTMENT General This appliance may be installed in an aftermarket, permanently located, manufactured home(USA only)or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.A conversion kit is supplied with the appliance. Contents Safety Alert Key 2 Section 8:Removing&Installing the Screen/Door 21 Introduction 2 Removing the Screen 21 Efficiency 2 Reinstalling the Screen 21 Section A:Before You Begin 4 Removing the door 21 Installation Checklist 4 Reinstalling the door 21 Standard Installation Checklist 5 Propane Conversion 22 Rating Plate Sample 6 Section 9:Installing the Accessories 24 Section 1:Dimensions 7 Installing the Fireglass or Optional Glass Media 24 DelRay Dimensions 7 DelRay 36"Optional Log Kit Installation 24 Section 2:Framing 8 Propane Driftwood Layout 24 In Wall and Corner Dimensions 8 Natural Gas Driftwood Layout 24 Alcove above the fireplace 8 DelRay 48"Optional Log Kit Installation 25 Clearances 9 Propane Driftwood Layout 25 Section 3:Venting 9 Natural Gas Driftwood Layout 25 Section 3-3-1:Venting Layout 10 Section 10:Cleaning and Maintenance 27 Wall and Roof mounted venting 10 General 27 Co-linear venting into existing masonry chimney 11 Cleaning 27 Section 3-2: Installing a Roof Mounted Direct Vent Termination Pilot Burner Adjustment. 27 for 4"/7"(MVTK-1) 12 POD-Pilot on Demand 28 Section 3-2-1:Venting Layout 12 What is POD mode? 28 Section 3-3:Installing a Wall Mounted Termination 4"/7" 13 Remote Continuous Pilot(CPI)Selection 28 Section 3-3-2:Venting Components 14 Installing the POD Jumper Cable 28 Section 3-3-2.2:4"x 7"Venting Components 15 Troubleshooting 29 Section 3-3-3:Heat Shields 4"/7" 16 Indoor fireplace in protected outdoor applications 30 Section 4:Wiring 17 See through fireplace 30 DRL**13(N/L)I Wiring Diagram 17 Notes 30 Installation of the wall switch 17 Single sided fireplace 30 DRL**13(N/L)I-2 Wiring Diagram 18 Appendix A:Venting Terminations 31 Installation of Electrical Supply 18 Appendix B:Warranty 32 Section 5:Installing the gas line 19 Appendix B:Warranty Continued 33 Fuel Type 19 Appendix C:Amendment 34 Gas Pressure 19 Section 5-3:GAS CONNECTION 19 (Gas Fireplace/Equipment sold in the State of Massachusetts)34 Finishing Safety Zone 19 DRL3613*I BASIC Exploded Parts 35 Section 6:Finishing 20 DRL3613*I-2 FULL LOAD Exploded Parts 36 Finishing Around the Fireplace 20 DRL4813*I BASIC Exploded Parts 37 Sidewall clearances 20 DRL4813*I-2 FULL LOAD Exploded Parts 38 Cement Board Install 20 RECEIVED 03/24/2021 XG0226-042220 ASPEN 3 BUILDING DEPARTMENT General Section A: Before You Begin Installation Checklist IMPORTANT MESSAGE:SAVE THESE INSTRUCTIONS • Determine the desired install location of your fireplace. The DelRay fireplaces must be installed in accordance with these • See Section 1, Dimensions on Page 6, and refer to the Framing instructions. Carefully read all the instructions in this manual first. Section 2 for details. Consult the Local Gas Branch to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to • Select the location of your termination and resulting vent run. ensure this fireplace is installed in compliance with the manufacturers instructions and all applicable codes. • Should it be impossible to meet the venting requirements laid out in Section 3:Venting,please contact your Montigo dealer regarding NOTICEthe use of a Montigo Power Vent. • Lay out the Vent run; calculating the required elbows and straight runs of 4"/7"flex and/or rigid pipe. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance • Layout Electrical Requirements refer to Section 4:Wiring,for Details. and to replace any part of the control system and any gas control that has been under water • Refer to Section 5: Installing the Gas Line, for details on the gas connection and access. • Refer to local codes and guidelines for installation requirements. NOTICE • Installation and repairs should be done by a qualified contractor and must conform to: Due to high temperatures,the appliance should be located out of • Installations in Canada must conform to the local codes or in the traffic and away from furniture and draperies absence of local codes to the current version of Natural Gas and Propane Installation Code, CSA B149. Electrical installations must conform to the local codes or,in the absence of local codes,to the current version of Canadian Electrical Code,CSA C22.1.1 NOTICE • Installations in the USA must conform to the local codes or in the absence of local codes to the current version of National Fuel Gas Code,ANSI Z223.1/NFPA 54. Electrical installations must conform Children and adults should be alerted to the hazards of high surface to the local codes or, in the absence of local codes,to the current temperature and should stay away to avoid burns or clothing ignition version of the National Electrical Code,ANSI/NFPA 70. See Appendix C for installation within the State of Massachusetts NOTICE NOTICE A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the Clothing or other flammable material should not be placed on or near protection of children and other at-risk individuals the appliance • This appliance may be installed as an OEM installation in a NOTICE manufactured home(USA only)or mobile home and must be installed in accordance with the manufacturers instructions and the Manufactured Home Construction and Safety Standard,Title 24 Installation and repair should be done by a qualified service person. CFR,Part 3280,in the United States,or the Standard for Installation in The appliance should be inspected before use an t -- • 1 Mobile Homes,CAN/CSA Z240 MH,in Canada. by a professional service person.More frequent i This appliance is only for use with the type(s)of gas indicated on required due to excessive lint from carpeting,bed . -'.1, 1 the rating plate.A conversion kit is supplied with the appliance. is imperative that control compartments,burners,and circulating air passageways of the appliance be kept c103/2 4/2 1 21 4 X4b QUI22o BUILDING DEPARTMENT General Standard Installation Checklist This standard installation checklist is to be used by the installer in conjunction with, not instead of,the instructions contained within this installation manual. Customer Date Installed: Install Address: Location of Fireplace: Installer: Model(circleone): DRL3613NI,DRL3613N1-2,DRL4813NI,DRL4813N1-2 Dealer Phone: DRL3613LI,DRL3613LI-2,DRL4813LI, DRL4813LI-2 Serial#: YES NO IF NO,WHY NOT? Appliance Install:Section 2 Framing complies with install manual. Standoffs have been installed. Proper clearances have been maintained. Venting:Section 3 Venting configuration complies with vent diagrams. Venting installed,fastened,and secured in place maintaining proper clearance. Firestops installed. Exteriorwall/roofflashinginstalled and sealed in compliancewith local building code. Terminations installed and sealed in compliance with local building code. Direct vent termination is highest point in vent assembly. Wiring/Electrical:Section 4 Unswitched power provided to the appliance PPO box. Low voltage wire connected to dry contact wall switch(non-powered)* Gas:Section 5 Proper appliance for fuel type. Was a conversion performed? Leak check performed&inlet pressure verified. Finishing:Section 6 Only non-combustible materials installed in non-combustible areas. Clearances meet installation manual requirements Mantels and/or projections comply with install manual Appliance Setup:Section 7 through 9 Media,door,and screen installed according to install manual Manual given to home owner. Started appliance and verified no gas leaks exist. Comments: RECEIVED *Only applicable for Builders Series 03/24/2021 XG0226-042220 ASPEN 5 BUILDING DEPARTMENT General Rating Plate Sample 2 d o E. d n A 'b r y mr aI►.�i 1\i ' E• t?, V R. ell g ro r po 9► ) 91 fx)111.3. is - 3o N • m m 0 N .A A - ❑ X m D m 1 O co 1 n X -i D m 1 v Na v o o I I m = � t`Dii - `� ac N 5• c -o o. c Z c C V Z= yO !: IU N O O W O so m .0 a .. d m -Q C 3 * 3d O 3 * co N to �' m Q O m = m O 0 oa m a m o z fD L) m ro y a O. O r o - o y m o. m a r - co y m 3. m 3 co. 0 a 3 0, 0 a. N v w 0 d 3 D co, a co v oNi m a' 3 A m. a 0 v0 Z 6 a m d a 0 -oo Z = a -• ei 0 0 a a 3 p = .. 0 0 a 01 3 w a .. N y m - ., D m` m cn N C - D m• m X. 2 _. a 3 D 0 - o w z a a z 0 2 a v CD a a v co a a C W C a m Co a m x m Co a m o, m N < a Z < Z D 0 n x v Z < cD W Z 11 D 3 0 x v Z < a• m d Go N ? x Z 7 m j on ? Z 7 m rn _ co a x o o 0 co _ I Co a j o o 0 uo, - o o c m - 0) o -y X c o O- H' o o C - m m X o a 0 0 0 0 = C w m 5) °' m o 0 — ^a' o o o = x co 0., o m m 0 0 2 0,v' O X Z CD c CD t0i N F. CA .- T T1 N N Si N 0 O cO "' N N Qp — m x N N w ti t 0 m c < 5 g * •' y -i 00 m o '< 5 X s U 2 _� y 0 i0 W 3-00- -co S - j CO 3 ' Q) o i0 X W 3-2O m. 2 °' .. Fos, -' O n o. 2 o o c m _ o N 7-9 0 3 x -` 0 0 m > > f) - o o 0 2 a N D m a 3 a = c a 0 0 - '. N D m n 3 a W N ' E. N W N o N S i- - D is 3 N -0 o n• S i- _ D w 3 N o m - Z ? 3 N Pt 0 co - N o F. w 3 w W o' N N o w 9 O <� 0 o - . t - Czi w a 0 :- oN m , -0 m m Z Z -1 a r O m m Z Z -a r o m D D o $ m �2 a -o pz D D C o a m < a , .o D — 0 3 D — o o m i= 6 a m D 9 a n N N SI 9 Ca W m. A -n o 30 <cl N g A T Q 30 < N 3 C ti .0.. E n G �I 9 c C "' 0 < 71 m 5 D m i E a co 0 - D o io 1 a o O < W O 0 an N < a) O N 0 N n F. N = N C] N 3 c Co 0 ' c^ 3 � o a io of ? 0 3 3 ' o as 3 a 3 3 m y o m 3 o m = 3 3 m y o y 3 0 cs 3 3 w m o. Q 5 3 3 3 w CT, IS or Cr a E, z Z o 0 3 m• » m = Z z o v 3 m _ o D D 3'O 0(IT 0 nFi o D D id� `� m 0 0 - N - = 0 L., • e 0 o �e -p 3 0 o �e 8 N O p ID 67, y 3 m w K m -I -I co to y 1 m n 3 m - -1 co to 3 0 o N O '00 0 C0i a 3 o 0 o N O '00 0 0 a g v y o o z v y a o 0 D o CO m Fo 0 0 (- o N G 3 w 3 y v a w a o - w 3 y v i a o+ m o, - Co ai y N ', it 0 F G o N' y vi y m V J n < N W 3 m m o a m o g m -D A, m > > m 0 C) O 3 p^ o C .. Cv v !0 n 0 C) O Ti O_ 3 0 .. Cc v i0 0 y 2 O C = m H a C = 0 d O_ 2 O 2 c c 3 N 3 m c a m a o m m. a 2 o m m. 3 F. < j� < y rti m a > o ni m ? I. o p v % Op a '� O f5C C v 3 D o 0 3 v 2 D a 0 3 D y 3 g N O c D y 3 �; O 0- N 3 c - .. C a N N 3 c - N C G N ms. W N 3 N 0 .. .. N 6 -n W N 5 N o .. .. N O' a * *< 5'm o- ao a * * 04 5'm 6 N W w O 2 n O a fall Z. p n n v 2 a . o,a c yv o. a c 2a o - L�m '< o - Lim n n N = Z Z W O Z a N (� (7 _ Z Z o O Z N n D D - S n D D - - o• w _ o G. RECEIVED Figure 1.1 Rating Plate for DelRay DRL3613N1-2 Figure 1.2 Rating Plate for DelRay DRL481 03/24/2021 6 XaH26 U1220 BUILDING DEPARTMENT Installation Section 1 : Dimensions DelRay Dimensions A A 5" 461 Ty 123/4" 125/16" B - [ I A _ ♦ A 263/4, 1411n6^ 241 2 165/8" 263/4- 3v8" 68. �❑° � I r n6^ < D Figure 2. DelRay Fireplace dimensions(Tolerance±yfi"). DRL*3613 DIMENSIONS DRL*4813 DIMENSIONS A BCD A BCD 413 38/6 361 45' 536/6 506/6 481 57/ RECEIVED 03/24/2021 XG0226-042220 AS EN 7 BUILDING DEPARTMENT Installation Section 2: Framing In Wall and Corner Dimensions Alcove above the fireplace 1). Frame in the enclosure for the unit with framing materials. The framed opening for the assembled fireplace shown below in table gym" NOTE:When constructing the framed opening,please ensure there is access to install the gas line when the unit is installed m. Framing header must I ,o 12„ be turned on edge to meet vent clearance e Figure 3.d Non-combustible Framing for shelves over the fireplace a WARNING [362] When this appliance is installed directly on ANY combustible other 14 4.. than wood flooring(carpet,vinyl,etc.).It must be installed on an A equivalent wood or metal panel.This material must extend the full width and depth of the appliance. DRL*3613 DIMENSIONS DRL*4813 DIMENSIONS A B C A B c 43% 67/s 47% 55% 79% 5616 NOTICE Figure 3.a Framing dimensions table Clearances must be in accordance with local installation codes and the requirements of the gas supplier *When sheetrock is used behind the fireplace,framing depth may be increased by 1/2". II 1 II II [1.2.700] , 2 /, �II c m A RECEIVED 03/24/2021 Figure 3.b Framing dimensions(Straight wall&Corner Installation). QQ � 8 Xab�26 U1220 BUILDING DEPARTMENT Installation Section 3: Venting Clearances Montigo offers a variety of direct venting and termination options.The direct vent termination location MUST be selected such that it is the highest point in the venting assembly. It should also be selected such When installing a shelf over the top of the fireplaces, the following that it provides the shortest vent run possible.Should it be impossible guidelines must be adhered to: to ensure that the termination is the highest point or to meet the venting guidelines laid out below please contact your Montigo dealer to discuss power venting options. D. �+ a ; a Notes For Planning Venting: p a 0 mOWW LL R C 1"all around • Venting originates from the top of the unit DRL**3613*I 21" 2" 1" 0" 6° 2"on the • Venting can terminate through the roof or through an exterior wall. horizontal • Refer to Appendix A-Termination Locations to ensure the planned 1"all around termination location is acceptable. DRL**4813*I 21" 2" 1" 0" 6" 2"on the horizontal • Once the termination location has been established, refer to the Figure 4. Combustible Wall Clearances appropriate section below for installation details • All fireplaces shipped from the factory are top vent. • Silicone application is NOT required when joining Montigo vent NOTES: pipes and components. t Clearance from top of fireplace to a ceiling within the fireplace enclosure. NOTICE Under no circumstances can Montigo flex venting be cut to accommodate an installation.Use an alternative length to complete your vent run.(Excluding flex included in the MVK05/MVKO5F) MVK05/MVKO5F MVK05/MVKO5F Flex Vent Kit is a standalone 5'vent kit that cannot be combined with Montigo Flex or Montigo Rigid pipe to extend beyond the 5ft of flex included in this kit.The Flex in this kit can be cut down if shortening is required.Any other venting configuration beyond the 5ft included in the MVK05 kit will require going to either Montigo Rigid pipe or Montigo Flex pipe referenced in the manual pages Venting section. Figure 4.a MVK05/MVKO5F Flex Vent Kit RECEIVED 03/24/2021 XG0226-042220 ASPEN 9 BUILDING DEPARTMENT Installation Section 3-3-1: Venting Layout OUTDOOR OUTDOOR WALL WALL FLEX PIPE MTO-4F MTO-4F I IIH � A �\ IIVI A Alli MI 1 13" I 16$" MIN. MIN �IT P Maximum Vertical vent run: 34'vertical length with a rooftermination, 371/2"Min. restrictor recommended. 40.652"Min. D UNI Maximum Horizontal vent run: 34'vertical length with 4 elbows, and the maximum 20 feet horizontal run. Ion _ ■n 'I ion _ on Figure 4.bb Minimum Horizontal vent run(Flex) Figure 4.bb Minimum Horizontal vent run(Rigid) Wall and Roof mounted venting 34'MAXIMUM VERTICAL HEIGHT 20'MAXIMUM HORIZONTAL OFFSETS 4 MAXIMUM 90°ELBOWS PERMITTED The minimum vent system for horizontal termination must consist of: C;) 13"to vent center,then straight out the wall(using flex kit) The maximum vent system consists of: tea 34' vertical length with 4 - 90° bends and a 20' horizontal length H2ftio ` C'�� (measured to center of pipe) !l Vf 3� .� y r�l HORIZONTAL TABLE Y / j (-)1 H1 `may H �� 4) Vertical Horizontal �WO � 11 r��� s 1111 r/� Minimum Maximum v2/� r11111 { \ ��,, rul V2 V1+V2 H1+H2+H3 r ` �'� /I `/ ,1I� 4' 10' ♦ /--„,, V1 4.0 8 20 VERTICAL TABLE \ � rot _ Vertical Horizontal �Ie H1 1���� Minimum Maximum f <.� �c�11,, V1+V2+V3 H1+H2 H2 ( ' V 4' 10' RIVEP g' 20 031 /2021 10 t314 `-' I220 BUILDING DEPARTMENT Installation Co-linear venting into existing masonry chimney The appliance can be adapted to co-linear applications using an existing chimney.The appliance must not be connected to a chimneyflue serving a separate solidfuel burning appliance such as a wood burningfireplace. • Maximum 30 feet vertical pipe • Minimum 10 feet vertical • Restrictor usage recommended for longer vertical runs • Keep the flexible liner as straight as possible,avoid unnecessary NOTICE bending • A maximum oftwo certified couplers may be used per length of3"liner • DelRay co-linear installation requires reducing from Montigo 4/7 The unit must be fully enclosed while maintaining clearances to to Duravent 4x6% combustibles detailed elsewhere in this manual 46DVA-CL33K termination) wind terminmin ation) .............................. ------- A Co-linear II portion of -- -- vent system may only be -- 10' installed within Min the fireplace -- Dual 3" -m . cavity and liners chimney. - •• 46DVA-CLAA - -- (Converts Duravent Direct vent to Co-Linear) .IN .... -- 30 _.—...... ... Max. 46DVA-AD-M1 '•-- (Part converts Montigo 4/7 to Duravent 4/6%) -- f - -- ME El El Hearth\ - y F Figure 99.a Co-linear top vented configuration. RECEIVED 03/24/2021 XG0226-042220 ASPEN„ BUILDING DEPARTMENT Installation Section 3-2: Installing a Roof Mounted Direct Vent Termination for 4"/7" (MVTK-1) This section applies to installations where the direct vent termination will be roof mounted. f MVTK1 Termination ut_ rt Storm collar 2'min Roof flashing Section 3-2-1: Venting Layout Support ring Selection of components and details of venting lay out should adhere 34'max Support plate to the following guidelines: obstacle • The maximum termination point is 34'above the fireplace(NOTE: if the maximum termination height is used,the flame pattern may �11111h Firestop be affected). • The Vertical termination must be a minimum 2'higher than where _ the termination exits the roofing materials,(asphalt shingles,cedar shakes,etc).This distance should be measured from the high side of the roofslopewheretheflueflashing intersectsthe roofing materials. • Termination location must be a minimum 6'from a mechanical air inlet. Figure 6.6 Top vent,roof mounted with 1 offset(1 offset=Iwo 90°bends). • For a more detailed diagram of allowed termination locations,see Appendix A. • A maximum of two offsets(each offset is made up of 2-90°bends)may be made for vertical vent runs.(2 45°bends are equivalent to 1 90°) • Firestops must be installed as required by National&local codes. • Ensure all horizontal runs are supported with a minimum of 3 supports per 10'of venting. • Install all roof flashing and storm collars as shown. MVTK1 Termination Storm collar I 2'min Roof flashing .01 Support straps OR Support ring and Roof mounted terminations plates Thefollowingdetails are some possible configurationsfor roof mounted IIIILterminations.See below. Firestop 34'max Support ring and MVTK1 Termination T � plates Storm collar 2'min Roof flashing 'I I I I _ • Firestop Support ring 34'max Support plate II I I I Obstacle 1 Firestop = Firestop 1 Figure 6.c Top vent,roof mounted with 2 offsets(1 offset=two 90°bends). RECEIVE() Figure 6. Top vent,roof mounted termination with no offset in vent run. 03/24/2021 12 XabW FM220 BUILDING DEPARTMENT Installation Section 3-3: Installing a Wall Mounted Termination 4"/7" This section applies to installations where the direct vent termination Installation of termination from inside structure will bewail mounted.NOTE:Ifsubjectto a highlycorrosive environment A Termination with a MOSR Frame is installed from the inside of the i.e.Seaside,Montigo recommends using Stainless Steel Termination. structure.These are commonly used in high-rise construction. MOSR Frame 1Y, Framing, concrete Installation of termination with built in frame _ orother fi materials A termination with a built-in frame is installed during framing of a rstructure.1.Frame the termination opening to 11"x 11". MTO-4(4"/7)TerminatioIExterior 2.Install exterior sheathing to the structure framing. Sheathing,concrete Fastening Hardware, or other materials 3.Fasten the termination to the sheathing usinga minimum of4screws. minimum 4-screws Figure 7.d Installing a MTO termination with MOSR frame. Framing r11•• Fastening Hard- 1. Frame the MOSR opening to 12"x 12". Exterior • ,I 7-ware,minimum p g Sheathing _ --. 4-screws 2.Fasten the MOSR frame to the interior side of the studs,concrete, MTO-4F(4"/7") or finished wall construction using a minimum of 4 screws. 11 I Termination 3.Insert the termination into the MOSR frame as shown here,(from '@'- : the inside)and attach to the MOSR by installing a min.quantity of 4 Figare7. Installing aMro4-Ftermination. bolts into the threaded nuts on the MOSR Frame. Installation of termination frame at time of framing Installation of a termination shield for vinyl siding Terminations with a MSR frame allow the installation ofthe frame prior The VSS Termination shield is installed when the exterior of a structure to installation of the termination. is clad with Vinyl siding.It is placed directly above,and on-center with 1. Frame the termination opening to 12"x 12". the termination. 2. Secure the MSR Frame to the exterior sheathing of the structure. SS Vinyl shield 3.Fastentheterminationtothe MSR Frame usinga minimum of4screws. •-- MTO-4(4"/7") Termination .111 Framing 12" MSR Frame ,f \ Exterior Vinyl Exterior Fastening Hardware, siding Sheathing ll' `.. _ �minimum 4-screws — 12•( MTO-4(4"/7") Figure i.e Installing the VSS Vinyl Shield. ' i Termination 11, ----- Installing heat guards Figure 7.b Installing a PTO termination with the MSR frame. Installing heatguardsoverterminations is recommended in installations where the termination is located within 7'feet above grade,or above a pedestrian walkway,and may be required by code in public areas. Installation of termination frame at time of framing in masonry Terminations with a BSR frame allow the installation of the frame in masonry prior to the installation of the termination III --- 1. Frame the BSR opening to 12"x 12". 2. Secure the BSR Frame to the exterior sheathing of the structure. -: "ram :.•—� 3.Fasten thetermination tothe BSR Frame usinga minimum of4screws. i/: ! if MTKOG 4"/7") Framing,,,, k_12'_ BSR Frame Figure 7.f Installing a MTO termination heat guard. Fastening Hardware, Exterior �� minimum 4-screws Sheathing _ _ / 1. Ensure that the two long mounting brackets are facing the bottom jJjI. II • MTO-4(4"/7") of the termination(Seeinset).Thiswillprovidemoreheat rote io 2 ler � Termination at the top of the termination,where temperas �ED II 2.Attach to the faceplate of the termination us� S r e!'al screws. Figure 7.c Installing a MTO termination with the BSR frame. O 3/^ w/^O^1 XG0226-042220 ASPEN13 BUILDING DEPARTMENT Installation Section 3-3-2: Venting Components Connection and installation of the vent Thefollowingcomponentsand associated Montigo part numbers are for components should adhere to the following installation of a roof or wall mounted termination.Use of non-Montigo guidelines: approved parts will VOID the warranty and may impede operation of the fireplace. • Use any combination of rigid and flex pipe as required and in any orientation(Male connectors can face in any direction). A-Termination MTO4 (3" Length) MTO4F (3" Length) • Flex sections may be stretched up to 50%of their total length(e.g. MTO4FSS a 24"section maybe stretched to 36"). B- Frame Kits MSR (Stucco Frame) • Connect all vent sections using a minimum of three sheet metal MOSR (Stucco Frame) screws on the outer pipe flue. BSR-4 (4" Brick Frame) • Ensure the pipe ends male to female slide in a minimum of 1 1/2" BSR-6 (6" Brick Frame) of overlap. C- Flex Sections MFL- 1 (12"f/f Section) • Ensure all horizontal runs are supported with a minimum of 3 MFL- 18 (18"f/f Section) supports per 10'of venting. MFL-2 (24"f/f Section) • When hanging/supporting venting, ensure that 1" clearance is MFL-3 (36"f/f Section) maintained on sides and bottom ofvent runs and 2"above horizontal MFL-4 (48"f/f Section) vent runs to any combustible material. MFL-6 (72"f/f Section) • Rigid pipe may be cut less thanhalfwayfromtheFEMALEENDONLY. D-Rigid Pipe MEXT- 1 (12"f/m Section) • Ensure when cutting sections of rigid pipe to maintain integrity of MEXT-2 (24"f/m Section) internal supports. MEXT-3 (36"f/m Section) • Flex pipe cannot be cut MEXT-4 (48"f/m Section) MEXT-6 (72"f/m Section) • Place the springs,supplied with the pipe kit(flex only),between the outer and inner pipes to keep the pipes separate and avoid any E- Rigid Pipe Extension EXT1 8 (18"f/f Section) possible hot spots. • Montigo recommends the use of a flex section for the first section of F-Elbows MEL-90MM (m/m 90° Elbow) venting connected directlyto the fireplace,offeringgreater flexibility MEL-9OFF (f/f 90°Elbow) of installation and absorption of movement. MEL-90FM (f/m 90°Elbow) • Firestops must be installed as required by national&local codes. MEL-45FM (f/m 45°Elbow) • Montigo recommends that all exterior corners and joints be sealed G-Wall Penetration Kit MFVK01 F with exterior caulking.However,we encourage you to consult your H-SupportRing&Plate MSPXT7 Building Envelope Engineer or Waterproofing Consultant for further recommendations. I-Firestop FS7 J-Roof Flashing MRF7 (1/12-7/12 pt.) MRF12 (7/12- 12/12 pt.) K-Heat Shield RHS100 IMPORTANT: L- Heat Guard MTKOG Please refer to your Building Envelope Engineer or Waterproofing Consultant for a review of ALL penetrations through exterior walls or the roof. RECEIVED 03/24/2021 14 *db3te U2220 BUILDING DEPARTMENT Installation Section 3-3-2.2: 4" x 7" Venting Components The following venting components are approved for use with Montigo products. Please contact your local Montigo dealer for further information. Component Montigo Part Number Simpson Duravent Part Number Flexmaster Part Number Termination MTO4 (3"Length) 46DVA-HC MTO4F (3"Length) 46DVA-VCH MTO4FSS Frame Kits MSR (Stucco Frame) MOSR (Stucco Frame) BSR-4 (4"Brick Frame) BSR-6 (6"Brick Frame) Flex Sections MFL-1 (12"f/f Connectors) 4DVKIT4701 MFL-18 (18"f/f Section) 4DVKIT4701.5 MFL-2 (24"f/f Section) 4DVKIT4702 MFL-3 (36"f/f Section) 4DVKIT4703 MFL-4 (48"f/f Section) 46DVA-48FF(48"F/F Section) 4DVKIT4704 MFL-6 (72"f/f Section) 4DVKIT4706 46DVA-120FF(120"f/f Section) Rigid Pipe 46DVA-06 (6"Section) 46DVA-09 (9"Section) MEXT-1 (12"f/m Section) 46DVA-12 (12"Section) 46DVA-18 (18"Section) MEXT-2 (24"f/m Section) 46DVA-24 (24"Section) MEXT-3 (36"f/m Section) 46DVA-36 (36"Section) MEXT-4 (48"f/m Section) 46DVA-48 (48"Section) 46DVA-60 (60"Section) MEXT-6 (72"f/m Section) Rigid Pipe Extension EXT18 (18"f/f Section) 46DVA-08A (8W'Length) 46DVA-16A (16"Length) Elbows MEL-90MM (m/m 90°Elbow) 46DVA-E30 (30°Elbow) MEL-9OFF (f/f 90°Elbow) 46DVA-E45 (45°Elbow) MEL-90FM (f/m 90°Elbow) 46DVA-E60 (60°Elbow) MEL-45FM (f/m 45°Elbow) 46DVA-E90 (90°Elbow) Wall Penetration Kit MFVKO1 F Support Ring&Plate MSPXT7 46DVA-ES(Elbow strap) 46DVA-RS(Roof support) Firestop FS7 46DVA-WFS 46DVA-WFS2 Roof Flashing MRF7 (1/12-7/12 pt.) 46DVA-F6(DS) (0/12-6/12 pt.) MRF12 (7/12-12/12 pt.) 46DVA-F12(DS) (6/12-12/12 pt.) 46DVA-FF(Flat Roof Flashing) Heat Shield RHS100 46DVA-WT 2DVWTE47 46DVA-WTS Heat Guard MTKOG Adaptors PVA5487(5/8 to 4/7 reducer) 46DVA-AD-M1 Mounting Adapter 46DVA-AD-M2 Termination Adapter (Montigo 4/7 to Duravent 4"x 6%") 46DVA-AD-M2 Termination NOTICE ` 1 Adapter DirectVent Pro 4"x 6%"requires the 46DVA-AD-M1 Mounting • RECEIVED Adapter to reduce from native 4"/7"size.A Montigo 4"/7" termination must be used by installing the 46DVA-AD-M2 Termination Adapter 46DVA-AD-M1 MouO31'24/2021 Adapter XG0226-042220 ASPEN15 BUILDING DEPARTMENT Installation Section 3-3-3: Heat Shields 4"/7" Installing a Wall Mounted RHS7 heat shield Installing a Wall Mounted RHS100 Heat shield The RHS7 Heat shield CANNOT be used WITHIN 36"horizontal or 60" The RHS100 Heat shield MUST be used where the RHS7 Termination vertically of the fireplace.For applications within these dimensions the CANNOT be used.Use the RHS100 within 36"horizontal or 60"vertical. RHS100 Heat Shield MUST be used. To install the RHS100,Slide the Inner Section over the vent pipe that To install the RHS7, frame an opening in combustible construction, will connect to the fireplace. Fasten the vent pipe to the back of the Figure 15.a below. Slide the Heat shield in place over the vent pipe fireplace with a Min.of three sheet metal screws. which attaches to the fireplace.After the fireplace and vent pipe has Next,slide the RHS100 outer section from the outside of the structure. been installed,clearances should match the dimensions in Figure 15.a To complete the installation fasten the Heat Shield Outer Section & Termination frame to the structure. 1"min.Both sides Typical RHS100 Heat Shield Outer Section / Drywall/sheetrock 1 RHS100 Heat Shield,inner Section 1"min. Termination \1 i / Vent pipe,from fireplace 1#1111 11111 RHS7 Heat Shield 11I4 Combustible framing 1"min. \ Combustible framing Figure 15.a RHS7 Installation.(Install by sliding over vent pipe where it passes through the Figure 15.c RHS100 Installation.(Install by sliding Outer Section over vent pipe where it passes combustible construction). through the combustible construction. Drywall/sheetrock RHS100 Heat Shield Outer Section RHS100 Heat Shield,inner Section Termination / Vent pipe,from fireplace RHS7 II Heat Shield It' 1udii1? . I ;.�: 1 1111111I1III1 �I I j -- r I• im MTO Termination 371/2'Min. Figure15.d Heat Shield.After sliding the outer section in place. "�3/8"min.Both sides Typical 3/8"min. Figure 15.b RHS7 Installation.(Minimum requirements). nner shield Outer shield 3/8"min. Combustible Framing RECEIVE[ Figure 15.e RHS100 Installation O /n A/n O n 1 16 AbW- M220 BUILDING DEPARTMENT Installation Section 4: Wiring DRL**13 (N/L) I Wiring Diagram O 0 SPARK ® � ® GREEN �NI X1 zN� WHITE �J BLACK SENSOR NM X3 'ADM /—Main Power —III— 120VAC 60Hz w 6 amps h LL • - TO ON/OFF .L. :1_, ei -1 WALL SWITCH BE: _ X4 � ®° �'^�.� III � 1E1wU 0 PGNALCP PBwRCN SO: • c �� YELLOW/GREEN i�v� X5 ORANGE 1U� 0 OI �11 cREEry 4 ir lift: 0 I ®O Ili 0000 0, 000000 o ID00000 0 0]0 MODEL Figure 15. Wiring diagram for DRL3613NI with SIT Proflame Electronic Ignition DRL3613*1 DRL4813*1 Installation of the wall switch Montigo supplies 15'of low voltage wire to be plugged into the control board.Connect to a standard single pole ON/OFF switch to the location of your choice.You may extend these wires up to 30'in length with a wire of equal quality. Installations in Canada must be electrically grounded in accordance with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes. Installations in the USA must be electrically grounded in accordance with local codes or, in the absence of local codes,with the National Electrical Code,ANSI/NFPA 70. Optional remote control available through your Montigo Dealer. RECEI\IED 03/24/2021 XG0226-042220 AS P E N17 BUILDING DEPARTMENT Installation DRL**13 (N/L) 1-2 Wiring Diagram BATTERY PACK I iii 1 1.SVnnTYPE lqW W1= ,.SV&S PE 1.5V AA TYPE I I;•! i SPARK © N• X2 • GREEN - RED » Pre WHITE MAIN Power 1.5vmTYPEI- L.n X1 =N• 120vac 60 hz BLACK �� rN• 6 amps SENSOR N•x3 BLACK • MAIN ON/OFF SWITCH LT • ( O� � l 7 xa to , _• M • • VARIABLE SPEED m,,,,,FwME el I •-•X5 COMFORT FANS &oilll Flo~ c 1• . p ®O PILOT/ ,EL,ow��AEE. I• • ORANG �� _ I GREEN r �� »—C1 ® 'I O I�I BURNER HALOGEN LIGHTS —»—C1 O 17 III$ 0> 0 O • Illn- . I III •• fii • x,o • • BLACK — 0• • • • WHITE 110V BV • • X11 • • RED BULB TYPE I• • • RED G4 SOCKET • • LED LIGHTS le ��� TRANSFORMER 12V1OW LED1-RED LED ;1 I(l�l LED2 AMBER LED ;I- r • LE MODEL DRL3613*I-2 DRL4813*I-2 Figure 17. Wiring diagram for DRL3613N1-2 with SIT Proflame Electronic Ignition Installation of Electrical Supply Installations in Canada must be electrically grounded in accordance with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes. Installations in the USA must be grounded in accordance with local codes or, in the absence of local codes,with the National Electrical Code,ANSI/NFPA 70. NOTE:If any of the original wire supplied with the appliance is replaced, it must be replaced with the same type,or its equivalent. RECEIVED 03/24/2021 18 Xabl26M2220 BUILDING DEPARTMENT Installation Section 5: Installing the gas line Fuel Type • Verify that your fireplace is compatible with your available gas type. A DANGER (Natural Gas or Propane shown by"N"or"L"in your model number • If gas type is not compatible,contact your local Montigo dealer. After gas line is connected,each appliance connection,valve and valve train MUST be checked while under normal operating pressure with either a Liquid Solution,or Leak Detection Device,to locate any Gas Pressure source of leak.Tighten any areas where bubbling appears or a leak is • Optimum appliance performance requires proper input pressures. detected until bubbling stops completely or leak is no longer detected. • Gas line sizing requirements will be determined in ANSI Z223.1/NFPA DO NOT use a flame of any kind to test for leaks.A fire or explosion 54 National Fuel Gas Code in the USAand CAN/CGA B149.1 in Canada. will occur,causing serious injury,property damage or death. Pressure requirements(during operation): A WARNING PRESSURE REQUIREMENTS An inspection of the explosion relief flappers and door MUST be made Gas Pressure Natural Gas Propane prior to lighting the fireplace.A faulty seal on the door gasket and/or Minimum inlet pressure 5.5in.w.c. 11in.w.c. explosion ports will result in products of combustion leaking into the Manifold pressure 3.Sin.w.c. 10in.w.c. living space and may result in carbon monoxide poisoning. Figure 20. Pressure Requirements Finishing Safety Zone • The manifold outlet pressure is setfrom thefactorytothe appropriate Take special care when finishing underneath the fireplace door due to pressure but should be verified. the location of the gas valve and control board.Any screw can possibly • To check pressures,control valves have a provision to remove a 1/8" puncture one ofthese components resulting in eithera non operational N.P.T.plug to be fitted with a hose barb. • Montigo requires a service shut off valve be located in an accessible unit or worse,a gas leak. location to isolate the gas supply. • Only install gas shut-offvalves approved for use bythe state,province, or other governing body in which the fireplace is being installed. Section 5-3: GAS CONNECTION • See Figure 20.b or 20.c for location of gas line access. • Flexible gas connectors must not exceed 2 feet in length, unless •allowable within local regulations. y�S4 • Connect gas ne to he or 8"gas t • • • Check appliance onnelction,tvalve a'nd v/alve train under normal 1"screw y 1)//eV OTFo pp safe zone Fy�F�� GyT operating pressure with a commercially available leak check solution. 4)- o111;%CCq DO NOT USE A FLAME OF ANY KIND TO TEST FOR LEAKS. • jr: NOTICE screw safe zone............. When pressure testing the fireplace,gas line,and input system follow the appropriate local codes for your area.DO NOT connect RECEIVEDthe fireplace to pressures in excess of 0.5 psig.(14"w.c.)This will damage the gas control valve. 03/24/2021 XG0226-042220 AS P E N 19 BUILDING DEPARTMENT Installation Section 6: Finishing Finishing Around the Fireplace Sidewall clearances Fireplace Facing Side wall clearances are 4".Combustible surrounds may be installed When sizing the finish material for your fireplace, it is important to with 4"clearance to the side of the fireplace as shown. remember the following:THE OPENING MUST NOT BE OBSTRUCTED IN ANYWAY-to do so restricts the air supplyforthe control compartments 111 Ill and heat exchanger it also prevents access for servicing controls. J TOP OF UNIT 24 ■■■■■■■■■■■■■ I 23 ■■■■■■■■■■■■■ 22 ■■■■■■■■■■■■■ Drywall 21 ■■■■■■■■■■■■■ 20 ■■■■■■■■■■■■■ 19 ■■■■■■■■■■■■■ Edge of door frame I4 0 Sidewall 18 ■■■■■■■■■■■■■ I 4„ 17 ■■■■■■■■■■■■■ Min. c 1615 ■■■■■■■■■■■■■ Figure 19.c Sidewall clearances E ■■■■■■■■■■■■■ 14 ■■■■■■■■■■■■■ lro 13 ■■■■■■■■■■■■■ NOTICE = 12 ■■■■■■■■■■■■■ , 10 ■■■■■■■■■■■■l� I Combustible 9 ■■■■■■■■■■■■V mantle allowed 8 ■■■■■■■■■■■■■ 7 """"""' 4"clearance in sidewall drawingdoes not apply to recession,unit 6 ■■■■■■■■■■■■■ PpY 5 ■■■■■■■■■■■■■ cannot be recessed into a wall. ■■■■■■■■■■■■■ Concrete board 4 ............. ............. t2 ■■■■■■■■■■■■■ L """"""' Top of fireplace opening Cement Board Install 1413 12 11 10 9 8 7 6 5 4 3 2 1 1/8"Gap Mantle width(In.) Install the supplied non-combustible cement board to overlap the new horizontal&vertical 2 x 4's, place the non-combustible wall board above the fireplace throat,allowing 1/8"clearance from the rim above the fireplace opening. Pre-drill the board with 1/8"drill bit and secure to framing with nails, use flat head sheet Combustible Mantle metal screws to fasten the board to the metal header. Height 6" Combustible Mantle SINGLE SIDED Depth 11" Top(Qty 1) Sides(Qty 2) Cut standard Gyproc/Drywall board to complete the installation of Drywall the surround.Fit the edge of the board to the rim around the fireplace opening.Fasten the board in place using standard drywall screws. .]f H[ioi]f 9„ A 9.. Figure 19. Combustible mantles and facings.(Not to scale) ® 0 ® o * o I [0 1 CAUTION B ® [7za] We recommend careful consideration be given to the effects of 28i6 elevated mantel temperatures which may be in excess of product o C design,for example:candles,plastic or pictures.This can cause 0 0 * melting,deformation,discoloration or premature failure of T.V.radio, and other electronic components. AWARNING ADRL**3613 DIMENSIONS C ADRL*R E IVED BFireplaces cannot be recessed into a wall cavity. 3a��s 12 28 vs sons 12 2a" s Figure 28. Supplied non-combustible cement board ditOrar/2 4/2 0 21 20 Xabg220 BUILDING DEPARTMENT Installation Section 8: Removing & Installing the Screen / Door Removing the Screen Removing the door Follow the steps below to remove,or install the fireplace screen and The door is removed in a few simple steps.Follow these steps below door. Before beginning any screen or glass removal,make sure that the to unlatch the door buckles and remove the door. unit has not been in operation and that it is at room temperature. STEP 1: Step 1:Locate the three tabs at the base of the screen. Remove lower valve blinds and screen setting bar. STEP 2: i�� Ensure the tool is firmly R` 011111 in the lower end of the slot,(as shown),Then pull toward you,door will `'i unlatch,repeat for other 't buckles. 111 Figure 21.d Pull door latches I 1 I STEP 3: Figure 20. Locate the three tabs at the base of the screen Pull the top of the door ,Il towards you,then lift the i ' door up and out of the Step 2: Lift out the Retaining Tabs and screen. fireplace frame. 1 idl Pull the bottom of the screen outward,then slide out the screen from Store in a safe place. aim the frame. Store in a safe place.The Screen is very fragile and can be easily torn, ,,,g/ dented or deformed.Refer to Figure 20.b below. Figure21.e Lift the door - Reinstalling the door - NOTE: Make sure the top and base of the door slips into the narrow channel in the frame to ensure proper placement. STEP 1: Line up the notch of the bottom of the door iiitil with the tab on the door channel. Figure 20.b Lift out the Retaining Tabs and screen J'v 4101 Reinstalling the Screen Figure 21.b Installing the door Follow the two previous steps to re-install the fireplace window. STEP 2: NOTICEBuckles are locked into place by pulling out and up,latch will pop into 11 ir Any safety screen,guard,or barrier removed for servicing an place. D appliance,must be replaced prior to operating the appliance • Figure 21.d Pull door latches 0 3/2 4/2 0 21 XG0226-042220 AS E N 21 BUILDING DEPARTMENT Installation Propane Conversion To convert the DelRay from Tools required 1.Shut off gas supply. Natural Gas to Propane, install the GCA010/GCA019 1). Torx T20 Screw Driver Bit conversion kit.The unit must 2). 1/2"Socket Driver 2.Remove the 2 screws securing the pilot cover to the media be disconnected from anytray. Remove 2 screws on burner clamp. gas supply,disconnected 3). 5/32"Allen Key from any electrical supply and 4). Needle Nose Pliers or batteries and removed from Small Flat Head Screw ....11 .0 any installation cavity. Driver 2). 1/4"Socket Driver 1 Parts included Figure 13. Removal of pilot cover 1). Propane burner orifice 2). Propane pilot orifice 3.Burner can now be removed. 3). Propane valve control (with mounting screws) .is For input rating,manifold pressure and orifice size, 4). Valve conversion label refer to sample rating plate 5). Conversion plate label 6). Conversion technician identifying label Figure 13.b Loosening the venturi 4.Use 1/2"Socket Driver to loosen off the NG gas orifice, replace with Propane orifice as included in package. A WARNING --- ---l _ .. An — • • •• A••••r•• rrrrr _ 41110 t 411110 This conversion kit shall be installed by a qualified gas fitter in r r r r_r r _` S 1 4 accordance with the manufacturer's instructions and all applicable 1. . 411111 codes and requirements of the authority having jurisdiction.If the �x 411, • . information in these instructions is not followed exactly,a fire, 4 explosion or production of carbon monoxide may result causing II♦ property damage,personal injury or loss of life.The qualified service . oft agency is responsible for the proper installation of this kit.The — IS — S — installation is not proper and complete until the operation of the Figure 13.c Removing the orifice converted appliance is checked as specified in the manufacturer's instructions supplied with the kit. 5.Remove natural gas mixer sleeve from burner. Reinstall burner a CAUTION ......_;-1 s a: The gas supply shall be shut off prior to disconnecting the electrical power,before proceeding with the conversion. J ' D Figure 13.c Removing the orifice 03/24/2021pp 22 c�dbte22o BUILDING DEPARTMENT Installation 6.Use screwdriver to carefully detach spring clip from the pilot 10.The pilot size can be adjusted using a flathead screwdriver to hood.(Spring clip will be reused) adjust"pilADJ"screw shown - , *4 lir Illat :ib', ‘ • . I `� / 11) Figure 13.d Removing the spring clip Figure 13.g Adjust pilot size 7.Remove pilot hood,then use allen key to remove pilot orifice. 11.The manifold and inlet pressure can be verified by using a op :e.�` manometer and a 1/8"rubber hose attached to the valve Ir •• ••�' ports shown here(top is manifold, bottom is inlet)Use a soap-based leak testing solution on the valve regulator while ;-••' •! ( the unit is operating to check for any leaks y�� • / , y �.•., --!..-•"-.-: Illri . . . dp 1 IP s, -• 0 ft .• e 4 ".• - Figure 13.e Removing the pilot hood,orifice 8.Insert Propane pilot orifice. Reassemble pilot assembly and �! hood. Figure 13.h Adjust pressure ports '-� 12.Fill out required information on Propane conversion gas fitter -"'--:Vi 1 :... sign off label,attach to reverse side of rating plate.Attach Rating plate conversion label to rating plate label.Place Valve 3 _ conversion label on valve face. \..*:10., • L 4" . Figure 13.f Insert propane orifice,reassemble burner , _, 9.See regulator instructions for guide on converting the pressure V0. `� regulator gasket. icy '",y Figure 13.i Label reverse rating plate :Oil— V1E-,i- --==,,, 11 tiliti......--. \(1 ,114:0 , i \7 ":.. Y --'i'lel,... D Figure 13.k Conversion label on valve 0 3/2 A/2 0 2 1 XG0226-042220 ASPEN23 BUILDING DEPARTMENT Installation Section 9: Installing the Accessories Installing the Fireglass or Optional ‘ • Glass Media ` ^' " ‘ -'-~+ Y t ••, The unit is supplied with fireglass.Optional fireglass maybe purchased _._ 4,i• 'i . -'�'• -�.. • Q i4' Once the glass door is removed place the firestones randomly across _ R` :'T .• ,. 7 �'�rQ, the pan and the burners as described in Figure 24 to 24.b _- n ,— _ , „� Note:Only cover the burner with one layer of firestones or fireglass. Figure 24.b Completed firestone installation DelRay 36" Optional Log Kit Installation A B c1 DE F @ a i The Fireplace has the option of installing a drift wood log set.Once #` (Gt ', the base media of fireglass,firestones,or speckled stones has been -I 1 placed the log set can be installed. Ensure logs are securely placed c � and will not tip or fall. j, '#41 ? '. !, Propane Driftwood Layout LOG H • r LOG J LOG G LOG I L _ r LOG D LOG A LOG F , r 5, r LOG B LOG C LOG E . 1 1 1 Natural Gas Driftwood Layout f LOG H 1/4 LOG G LOG C LOG E 4 I 71FillifCW' .4 - . 1._ _rritmL_I_,i-__:-L.kii'ii ii;LJL __._'' •,.._ . __,,, ' LOG B , , LOG D LOG A RECE I D LOG I LOGJ 03/24/2021 24 XaQUi220 BUILDING DEPARTMENT Installation DelRay 48" Optional Log Kit Installation A B c E F G C� i K L The Fireplace has the option of installing a drift wood log set.Once the base media of fireglass,firestones,or speckled stones has been LGS77 placed the log set can be installed.Ensure logs are securely placed and will not tip or fall. Propane Driftwood Layout `LOG H / LOGE LOG K LOG C LOG G �' �/. �' 'wl ram- LOG F LOG D LOG A LOG L \ LOG I LOG J LOG B . l . . J Natural Gas Driftwood Layout , , LOG K LOGE LOG L e LOG H LOG G • LOG F LOG D LOGJ . ; 4 1 D R . LOGI LOGC LOGA 03/24/2021 1 i . . XG0226-042220 AS P E N 25 BUILDING DEPARTMENT Operation FOR YOUR SAFETY - READ BEFORE LIGHTING: J Ak ' ANGER CZHASE UN DOOT NOTGL TOUCH CAUSE GLASS B UNTILRS. COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed for the protection of children and other at-risk individuals. WARNING: If the information in these instructions is not followed exactly,a fire or explosion may result causing property damage,personal injury or death. WARNING/CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children,clothing,furniture,gasoline and other liquids having flammable vapours away. See installation and operating instructions accompanying this appliance for more information. • Immediately call your gas supplier from a neighbour's phone. A.This appliance is equipped with an ignition system that Follow the gas supplier's instructions. lights the pilot burner automatically.Do not attempt to ■ If you cannot reach your gas supplier,call the Fire Depart- light the pilot by hand. ment. B. BEFORE LIGHTING smell all around the appliance area C. Use only your hand to operate gas control.Never use tools.If for gas. Be sure to smell next to the floor because some the control does not function,don't try to repair it,call a qualified gas is heavier than air and will settle on the floor. service technician.Force or attempt to repair may result in a fire What To Do If You Smell Gas: or explosion. • Do not try to light any appliance. D. Do not use this appliance if any part has been under water. • Do not touch any electrical switch;do not use any Immediately call a qualified service technician to inspect the phone in your building. appliance and to replace any part of the control system,and any gas control which has been under water. LIGHTING INSTRUCTIONS: 1. STOP! Read the safety information above on this label. 6. If the Fireplace does not light,the System will cycle through two 2. Turn"ON"manual"ON/OFF"switch.(If available) trials,(one minute audible clicking,thirty seconds of silence, and then another one minute of audible clicking).If the system 3. Turn Incoming gas shut off valve to the ON"position. locks out due to inadequate gas flow,refer to"Troubleshooting" 4. Wait 5 minutes to clear out any gas. If you smell gas, in instruction guide. STOP!Follow"B"in the safety information above on this 7. After completion of the information in the Troubleshooting sec- label. If you don't smell gas,go to the next step. tion,Repeat step 5. 5. Turn fireplace"ON"using wall switch or remote control. 8. If the system will not function correctly,follow the instructions "To Turn Off Gas To Appliance"and call your service technician Main ON/OFF Switch or gas supplier. Mein Hemesa Sensarlgnit.r — Stepper Motor Manifold Pressure Swt - Test Connection • IRON r ® • ....r, ..4i (07, 4 ' ef J))111111141r I �, Output Regulator Control(Optional) 3.15A Fuae power Inlet Pressure SW1=Programing Button Test Connection Pilot Adjustment Screw LEDI=Red Diagnostic Light LED2-Amber Progressing Remote Control Light Gas Valve Typical Control Module shown TO TURN OFF GAS TO APPLIANCE: r 1. Turn off fireplace using wall switch or remote control. 2. Turn the incoming gas shut off valve to"Off". m RECEIVED 03/24/2021 26 Ab/26 Ui220 BUILDING DEPARTMENT Operation Section 10: Cleaning and Maintenance General Pilot Burner Adjustment. • Have the fireplace and installation inspected yearly.The inspection 1. Locate Pilot Adjustment Screw.(See figure 28) must include,but is not limited to,the following: 2. Adjust pilot screw to provide properly sized flame as shown. • Avisual check of the entire vent system and termination,where 3. After installing or servicing,leak test with a soap solution with main accessible. burner on.Coat pipe and tubingjoints,gasket etc.with soap solution. • An inspection of the explosion relief flappers and the door Bubbles indicate leaks.Tighten any areas where the bubbles appear gaskets to ensure a proper seal. until the bubbling stops completely. • An inspection of the burner,vent run,and primaryair openings. Manifold Pressure • An inspection ofthe gas valve,gas components,and pilotflame. Test Connection For your convenience a 1/8"manifold pressure tap is supplied on the gas valve for a test gauge connection. — ����- • Inspection of all optional equipment;fans,thermostats,remote =�� ' ' control lights,etc. � ��_. k• • For Natural Gas this appliance requires a minimum inlet pressure ���;� of 5.5"W.C.and a manifold pressure of 3.5"W.C. , `� ,• eeL• ;J • For Propane Gas this appliance requires a minimum inlet pressure ••' `e1ill-11112 of 11"W.C.and a manifold pressure of 10"W.C. `JO 0 • Always keepthefireplacearea clearandfree of combustible materials, Inlet Pressure as well as gasoline and other flammable vapors and liquids. Test Connection Pilot Adjustment Screw • Do not use this appliance if any part has been under water. Immediatelycall a qualified servicetechnicianto inspecttheappliance Figure 28. Pilot Adjustment on the SIT Proflame 2 gas valve. and to replace any part of the control system and any gas control which has been under water. • Inspection of glass doors and screen for damage and proper installation. NOTICE Do not use ammonia or abrasive cleaners on the glass,they will Cleaning permanently etch the surface.Use an approved gas fireplace cleaner such as Kel-Kem or White off. When the fireplace is first activated,there may be some smoke and a visible film may be left on the glass.This is a normal condition,and is the result of burning of protective coatings on new metal. • Glass must be cleaned periodically to remove any film(which is Annual inspection list for determining safe operation of a normal by-product of combustion)which may be visible. Film a direct vent gas fireplace can easily be removed by removing the door. Handle the door carefully,and clean it with non-abrasive, non-ammonia based glass cleaners.One of the most effective products is Kel-Kem. 1) Inspect and operate the pressure relief mechanism to verify relief mechanisms are free • During the initial firing,Silicone seals will "off gas", leaving a from obstruction to operate. visual deposit of a white substance on combustion chamber 2) Clean glass window with a suitable fireplace glass cleaner.Abrasive cleaners must not walls.This can easily be removed using normal household be used.Be careful not to scratch the glass when cleaning. products. 3) Inspect the operation of the flame safety system Pilot or Flame rectification device. • Use a vacuum cleaner or whisk broom to keep the control 4) Inspect and ensure the lighting of the main burner occurs within 4 seconds of the compartment, burner,and firebox free from dust and lint. main gas valve opening.Visual inspection should match that outlined in the appliance instruction manual.Inspect primary air openings for blockage. 5) Inspect condition of vent and vent terminal for sooting or obstruction and correct if present. 6) Vacuum and clean any debris in the firebox that is not supposed to be there. 7) Test and measure the flame failure response time of the fla a de-energize the safety shutoff in no more than 30 seconds. 8) Check all accessible gas-carrying tubes,connections,pipes a 04 en s or leaks. 03/24/2021 XG0226-042220 AS EN 27 BUILDING DEPARTMENT Installation POD - Pilot on Demand What is POD mode? Installing the POD Jumper Cable This appliance is equipped with an "On Demand" intermittent pilot 1).Access the control box. ignition system (IPI) which also includes a continuous pilot ignition (CPI)mode with an integrated seven day timer. 1.1. 34.t. ,4 1.`7-: In IPI mode,the pilotwill light beforethe main burner,when theappliance "� is turned on using a wall switch,remote orfrom a thermostat.Once the appliance is turned off,the main burner and pilot flame will shut down. ' ':/.,- ., The continuous(CPI)mode exists to ease the startup phase in colder climates bykeepingthefireboxandventingwarm whenthe main burner 1 , \ is not in use.The timer automatically switches off the pilot when the appliance has not been used for seven days. • 1 „ When the CPI function is turned on, the pilot will remain on after the fireplace is turned off.A timer will then begin the countdown for . / _ approximately seven(7)days before shutting offthe pilot ifthe appliance j is not used.This countdown will reset anytime the burner is use. If your appliance is equipped with a remote control device capable of Figure 19.a Open the control box drawer selecting IPI/CPI modes,refer to remote operating instructions. 2).Remove the bag containing the Jumper Cable from the wire In order to start your pilot, turning the main burner on with the harness connected to the controller. switch,remote or thermostat and then turning it off will reactivate the _ continuous pilot mode and reset the seven day timer. • ` . A jumper is supplied with this unit that can be plugged into the wire o�°�/ harness connected to the controller. This jumper cable gives the '��! , t Remote Control the ability to operate the POD/IPI switch and set the 1 eil unit to operate in either condition.Please refer to jumper installation4: ,.--- instructions for more information. • Remote Continuous Pilot (CPI) J Selection 0 111P. • Requires installation of the CPI JUMPER Figure 19.b Locate Jumper cable With the system in"off" position press the Mode Key,to index to the CPI mode icon, Pressing the Up Arrow Key will activate the 3).Find the corresponding plug attached to the control wire harness Continuous Pilot Ignition mode(CPI). Pressing the Down Arrow and connect the CPI jumper. Key will return to IPI.A single"beep"will confirm the reception of T _ �� Pi. , a —�) the command. ,.�{lj' ....In� /aQ IF •F fsi F�, 7is =_ i/m ON I on !pi * Film:Fill / x.,_ . �it ' �. e.' ■■ ■ I Figure 19.c Connect CPI RECEIVED 4).See operation section to turn remote into POD mode. 03/24/2021 28 AHR 22O BUILDING DEPARTMENT Appendix Troubleshooting The following is a troubleshooting chart of possible problems: PROBLEM SOLUTION Pilot Igniter wont 1. Check the MAIN ON-OFF switch (typically located below the spark valve cover)and turn ON 2. Ensure main power is ON or new batteries are installed in the remote control and backup battery pack(if available). 3. Check the 3.15A fuse in the control box and replace if necessary Pilot Igniter 1. Verify the Inlet and Manifold Gas Pressure are within sparking,but Pilot acceptable limits burner will not light 2. Check all connections to gas valve 3. Check connection to stepper motor(if available) Pilot lights,but 1. Check and verify all wiring connections as per the wiring Main burner will not diagram. Light 2. Verify the inlet and Manifold Pressure are within acceptable limits Pilot lights,but 1. Check the Pilot Flame Sensor Rod and clean with steel wool Main burner will or similar. not Light and igniter continues to spark 2. Check the Pilot hood and clean with steel wool if dirty. 3. Adjust pilot flame using the pilot adjustment screw if the pilot flame is too long or too short(Flame should fully engulf the sensor rod and must be stable). 4. Check and make sure the ground wire from the pilot is connected to the fireplace body. If your fireplace still does not operate correctly,consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts,optional fans,and optional trim finishes are available from your local Montigo dealer. RECEIVED 03/24/2021 XG0226-042220 ASPEN29 BUILDING DEPARTMENT Appendix Indoor fireplace in protected outdoor applications This fireplace may be installed into outdoor locations provided they are suitably protected from direct water impingement.However,all installation clearances in the appliance manual must be observed. Framing, Clearances to Combustibles, Mantel Heights, Facing Requirements, Venting Installation,etc.Use supplied Safety Screen. Dimension"A" X.75 =min.overhang depth Example formula The overhang must extend at least 75%of the roof line height(A) Min.overhang= Height is measured from bottom of fireplace opening to the ceiling A x 0.75 For example:if distance A is 84",the overhang must extend at least 63" See through fireplace Single sided fireplace • II See table for See table for F min.overhang —► •t— min.overhang depth depth I Outdoor area Outdoor area —-=— Outdoor area lIE A_i_ III "A"dimension is —.^— "A"dimension is from bottom of from bottom of fireplace opening �-O_ fireplace opening to bottom edge of to bottom edge of Fireplace cannot overhang overhang penetrate building T envelope Bottom edge of fireplace opening I __ Notes • Overhang requirements must be applied to both the front and sides of the • Follow all product installation instructions;including framing,clearances to fireplace combustibles,mantel heights,Facing Requirements,venting installation, • Indoor see-through models cannot be installed as indoor/outdoor etc.Use supplied safety screen. fireplaces,as air flows through both sides of the fireplace. • All wiring connections to line power shall be in accordance with outdoor • If the fireplace will be in contact with salt water,then an outdoor fireplace is requirements of;NECA NFPA 70 in the USA Canadian Electrical Code,CSA C22.1 for Canada. recommended • The Fireplace is not to be operated in temperatures below freezing(0°C I • Follow all building codes,including those addressing fireplace penetration 32°F) of an exterior building envelope NOTICE Units with tempered glass doors are vulnerable to rapid and/or extreme changes in temperature(thermal shock).Take care to prevent water from contacting the fireplace,especially if it is hot. RE('E IVE 0 03/24/2021 30 XaHCUi220 BUILDING DEPARTMENT Appendix Appendix A: Venting Terminations Covered Covered Above DBbll Alcove Detail 2' 2, 2• VIrryl Siding 2' ////Inside Come\\\\\\ Alcove Detail —1...„ , l 1 ' TNI T 17.5' 29.5' r J 5.f T-03;, _ Ot, f R ....c. M st Seea fold! A jy �� F k•■■■■. G L 11" rs / L.—A f—..., NE Fad } E + . All measurements Doted openawe Flood ae tid -1— rgiven are to the 1 fH �� rytiqr centre of the • �,' 4— termination ppe N 11" not the frame. �.� /. • I IP- B t° B A 5'w, -_-=vent termination ® =air supply inlet '///l, =area where termination-is not permitted Location Canada* USA** A clearance to the termination frame above grade,veranda,porch,deck,or balcony 12 inches 12 inches B clearance to top of doors or operable windows 12 inches 12 inches C clearance to sides or bottom of door or operable windows 12 inches 9 inches D clearance to permanently closed window when installed with approved glass penetration termination 0 0 E clearance to permanently closed window Recommended to prevent condensation 16 inches 16 inches F clearance to ventilated soffit located within a horizontal distance to 24 inches from centerline of termination 22 inches 22 inches G clearance to unventilated soffit 30 inches to combustibles 30 inches to combustibles 16 inches to non-combustibles 16 inches to non-combustibles H clearance to outside corner 9 inches 9 inches I clearance to inside corner 12 inches 12 inches J clearance to each side of the vertical centerline of a metre or regulatory assembly to a maximum vertical distance of 15ft 3 feet 3 feet K clearance to service regulator vent outlet 3 feet 3 feet L clearance to non mechanical air supply inlet to the building or combustion air inlet to other appliance for appliance<= 12 inches 12 inches 100.000 BTU/H(30 KW) M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or paved driveway located on public property 7 feet 7 feet P 22 inches to combustibles 22 inches to combustibles clearance under veranda,porch,deck,or balcony 16 inches to non-combustibles 16 inches to non-combustibles Q clearance above roof i 2 feet 2 feet R clearance to adjacent walls and neighboring buildings 2 feet 18 inches S clearance from corner in recessed location 12 inches 12 inches T Maximum depth of recessed location 4 feet 4 feet U Maximum width for back wall of recessed location 2 feet 2 feet ✓ Horizontal clearance between two terminations that are level 0 0 W Horizontal clearance(centre to centre)between two terminations that are not level 18 inches 18 inches Note 1:For N a vent shall not terminate directly above the sidewalk or paved driveway which is located between two single family dwellings and serve both dwelling. Note 2:For P only permitted if veranda,porch,deck,or balcony is fully open on a minimum of two sides beneath the floor Note 3: K,and specified in CGA B149 installation code.Local codes or regulations may vary. RE(' EI'IED*Based on on CGA B149.1.1 Natural Gas and Propane installation code.Local codes may vary,please check with local regulatory agency. **Based on ANSI Z223.1/NFPA 54 National Fuel Gas Code.Local codes may vary,please check with local regulatory agency. 03/24/2021 XG0226-042220 ' `SPEN31 BUILDING DEPARTMENT Appendix Appendix Be. Warranty MONTIGO RESIDENTIAL WARRANTY PROGRAM excessive temperatures will result in a fire hazard and void all warranties.This warranty is transferable.The appliance must Canadian Heating Products Inc.and/or Montigo DelRay Corp remain in its original place of installation to be valid. (collectively referred to herein as"The Companies"),warrants the Montigo gas appliance(referred to herein as'the appliance')to If the components of the appliance covered by this warranty be free from defects in materials and workmanship at the time are found to be defective within the time frame stated(see The of manufacture.The gas appliance and related components are Companies investigation of claims),The Companies will,at its further subject to the terms and conditions set forth below. option, replace or repair defective components of the appliance manufactured by The Companies at no charge and will also This warranty covers the following Montigo product series: pay for labor costs(in accordance with schedule)incurred in Distinction,Divine&Divine Outdoor(H-Series),Illume(FID Inserts), replacing or repairing components. If repair or replacement Phenom(L/P/PL-Series),Exemplar(R/RP-Series),Mahana and DelRay is not commercially practical,The Companies will,at its sole discretion,fully discharge all obligations under the warranty by Component Coverage Period Labor Coverage refunding the verified dealer purchase price of the appliance, Firebox,heat exchanger lsyears 1 year excluding the cost of labor unless the labor is covered by the Main burner 15 years 1 year terms of the warranty. Gas control valve and related control components This warranty covers only parts and labor as provided above. (pilot assembly,spark electrode flame sensors, 1 year 1 year In no case shall the companies be responsible for materials, thermopile) components or construction,which are not manufactured or Electrical components(internal blowers,ignition supplied by The Companies,or for the labor necessary to install, control module,wiring,switches,remote control 1 year 1 year repair or remove such materials,components or construction.All systems,blower control module,accent bulbs) replacement or repair components will be shipped F.O.B.from Firebox media(logset,glass beads,river rocks) 1 year 1 year the nearest Company factory. Glass(thermal breakage) 1 year 1 year Plated,painted finishes(including interior reflective lyear lyear LIMITATION ON LIABILITY glass) Refractory lining 1 year 1 year It is agreed and understood that The Companies sole obligation, Mesh/Glass safety barriers 1 year 1 year and purchaser's exclusive remedy under this warranty,under Powerventtermination 1 year year any other warranty,expressed or implied,or in contract,tort or otherwise,shall be limited to repair, replacement or refund as Montigo terminations* 10 years 1 year specified above.The opinion of The Companies with respect to Montigo venting(excluding termination) 15years 1 year these matters shall be final. *Exterior painted surfaces exempt In no event shall The Companies be responsible for any incidental or consequential damages caused by(but not limited QUALIFICATIONS TO THE WARRANTY to)improper installation, installation by an unqualified or unauthorized installer,accident, lack of regular maintenance, This Warranty only covers gas appliances installed in the United user error,abuse, misuse,Acts of God,power surges,floods, States or Canada. natural disasters,force majeure,defects in its appliance whether such damage occurs or is discovered before or after replacement To receive the benefits of this warranty,the appliance must or repair,and whether or not such damage is caused by The be purchased, installed and serviced annually by a dealer Companies negligence.Some jurisdictions do not allow the authorized by The Companies for the warranty to be valid. exclusion or limitation of incidental or consequential damages, The gas appliance must be installed by a licensed professional so the above limitation or exclusion may not apply to you.The in accordance with The Companies' installation instructions duration of any implied warranty with respect to the appliance and local building codes.The warranty on the appliance covers is limited to the duration of the foregoing warranty.Some only components manufactured by The Companies.The use of jurisdictions do not allow limitations on how long an implied components manufactured or supplied by other manufacturers warranty lasts,so the above limitation or exclusion may not and used in conjunction with the appliance could create serious apply to you. safety hazards, may result in the denial of certification by recognized national safety agencies and could violate local building codes.Such use may untimely void this warranty.This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies. The appliance must be subjected to normal use.The appliance RECEI\IED is designed to burn natural gas(NG)or liquefied petroleum(LP) only. Burning conventional fireplace fuels such as wood,coal or any other solid fuel will cause damage to the appliance, produce 03/24/2021 32 xaggM220 BUILDING DEPARTMENT Appendix Appendix Be. Warranty Continued EXCLUSIONS TO WARRANTY USA Offices Corrosion or rust of any kind due to a lack of maintenance, 6955 Salashan Parkway inadequate combustion air or improper venting and corrosive Ferndale WA,98248 chemicals/environments,expansion and contraction of metals or minor movements of components causing noise are not covered techsupport@montigo.com by this warranty. Willful misconduct(i.e. use of the appliance with problems Canadian Offices known to the purchaser and causing further damages), including 27342 Gloucester Way unauthorized or self-performed 'fixing'or exploration of the appliance's internal workings will void the warranty. Langley, BC V4W 4A1 Appliances on which the serial number has been altered, defaced, techsupport@montigo.com removed or made illegible will void the warranty. Costs incurred for diagnosis,service work,shipping and handling The terms and conditions of this warranty may be altered or of defective or replacement parts are not covered under this amended from time to time without prior notice. warranty. The published warranties are not applicable for any equipment WARRANTY PERIOD:Warranty coverage begins on the date of manufactured by The Companies that has been sold direct to original purchase. In the case of new construction,warranty the consumer via Internet or auction websites.The Companies coverage begins on the date of first occupancy of the dwelling do not endorse,approve or certify any online sale of its products or six months after the sale of the product by an independent, through auction websites,online retailers or any other method authorized Company dealer/distributor,whichever occurs of online sales direct to consumers. earlier. INVESTIGATION OF CLAIMS AGAINST WARRANTY The Companies reserve the right to investigate any and all claims against this warranty and decide upon method of settlement. The Companies are not responsible for work done without written consent of The Companies. The Companies shall in no event be responsible for any warranty work done without first obtaining the Companies written consent. The Companies employees and dealers have no authority to make any warranties to neither alter this warranty nor authorize any remedies in addition to or inconsistent with those stated within this warranty. IF WARRANTY SERVICE IS NEEDED To make a claim under this warranty,contact your installing dealer or contractor.The installing dealer is responsible for providing service and will contact the companies to initiate warranted parts replacements. In the event the installing dealer is unavailable,contact your nearest authorized Montigo dealer (www.Montigo.com)or contact Montigo direct at techsupport@ montigo.com. Ensure you have your sales receipt and the model and serial number of your appliance. DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF If you cannot locate the installing dealer,or nearest dealer/ RECEIVED distributor,you must notify The Companies in writing. 03/24/2021 XG0226-042220 ASPEN33 BUILDING DEPARTMENT Appendix Appendix C: Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as 4. INSPECTION.The state or local gas inspector of the side wall follows: horizontally vented gas fueled equipment shall not approve Existing chimneys shall be permitted to have their use continued the installation unless,upon inspection,the inspector observes when a gas conversion burner is installed,and shall be equipped carbon monoxide detectors and signage installed in accordance with a manually reset device that will automatically shut off the with the provisions of 248 CMR 5.08(2)(a)1 through 4. gas to the burner in the event of a sustained back-draft. (b) EXEMPTIONS:The following equipment is exempt from 248 (2) Revise 10.8.3 by adding the following additional requirements: CMR 5.08(2)(a)1 through 4: (a) For all side wall horizontally vented gas fueled equipment 1. The equipment listed in Chapter 10 entitled"Equipment Not installed in every dwelling,building or structure used in whole Required To Be Vented"in the most current edition of NFPA 54 as or in part for residential purposes,including those owned adopted by the Board;and or operated by the Commonwealth and where the side wall 2. Product Approved side wall horizontally vented gas fueled exhaust vent termination is less than seven(7)feet above equipment installed in a room or structure separate from the finished grade in the area of the venting,including but not dwelling,building or structure used in whole or in part for limited to decks and porches,the following requirements shall residential purposes. be satisfied: (c) MANUFACTURER REQUIREMENTS-GAS EQUIPMENT VENTING 1. INSTALLATION OF CARBON MONOXIDE DETECTORS.At the time SYSTEM PROVIDED.When the manufacturer of Product of installation of the side wall horizontal vented gas fueled Approved side wall horizontally vented gas equipment equipment,the installing plumber or gas fitter shall observe provides a venting system design or venting system that a hard wired carbon monoxide detector with an alarm and components with the equipment,the instructions provided battery back-up is installed on the floor level where the gas by the manufacturer for installation of the equipment and the equipment is to be installed. In addition,the installing plumber venting system shall include: or gas fitter shall observe that a battery operated or hard wired 1. Detailed instructions for the installation of the venting system carbon monoxide detector with an alarm is installed on each design or the venting system components;and additional level of the dwelling,building or structure served by the side wall horizontal vented gas fueled equipment. It shall be 2. A complete parts list for the venting system design or venting the responsibility of the property owner to secure the services of system. qualified licensed professionals for the installation of hard wired (d) MANUFACTURER REQUIREMENTS-GAS EQUIPMENT VENTING carbon monoxide detectors SYSTEM NOT PROVIDED.When the manufacturer of a a. In the event that the side wall horizontally vented gas fueled Product Approved side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic,the hard equipment does not provide the parts for venting the flue wired carbon monoxide detector with alarm and battery back- gases,but identifies"special venting systems",the following up may be installed on the next adjacent floor level. requirements shall be satisfied by the manufacturer: b. In the event that the requirements of this subdivision can 1. The referenced"special venting system"instructions shall not be met at the time of completion of installation,the be included with the appliance or equipment installation owner shall have a period of thirty(30)days to comply with instructions;and the above requirements;provided,however,that during said 2. The"special venting systems"shall be Product Approved by thirty(30)day period,a battery operated carbon monoxide the Board,and the instructions for that system shall include a detector with an alarm shall be installed. parts list and detailed installation instructions. 2. APPROVED CARBON MONOXIDE DETECTORS.Each carbon (e) A copy of all installation instructions for all Product Approved monoxide detector as required in accordance with the above side wall horizontally vented gas fueled equipment,all venting provisions shall comply with NFPA 720 and be ANSI/UL 2042 listed instructions,all parts lists for venting instructions,and/or all and IAS certified. venting design instructions shall remain with the appliance or 3. SIGNAGE.A metal or plastic identification plate shall be equipment at the completion of the installation. permanently mounted to the exterior of the building at a (3) After NFPA-54 section 10.10.4.2 add a new section 10.10.4.3 as minimum height of eight(8)feet above grade directly in line with follows: the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment.The sign shall read,in print When more than four gas appliances are to be vented through a size no less than one-half(1/2)inch in size,"GAS VENT DIRECTLY common gas vent or common horizontal vent manifold,a plan of BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS". the proposed vent installation shall be submitted to the Inspector and the serving gas supplier for review and approval. Extraction from:Massachusetts Rules and RegulaggAft r.NED 5.00:Amendments To 2002 Edition Of ANSI Z223. 14 IC 03/24/2021 popm 34 Xa '0 220 BUILDING DEPARTMENT Appendix DRL3613*I BASIC Exploded Parts © p Io1111. . \ \ ,. ' I! ..1.\\•.... .•.•. ........\..., 1.:IttL-0'17,,, v,',$. IL."1--_41-‘1' ,.____________ • iiii ,,,,, ... \r _ 1. 0 • O m o v a)fl a _ - na u ��� Standard Parts � 17 I 1 CEMENT BOARD CBSDRL36 ... ...4 _ 19 iiir 2 SCREEN RSCDRL3613 3 DOOR RDTDRL3613 " � 4 VALVE COVER RVBDRL3613 20 5 BURNER ASSEMBLY RBDRL3613 18 6 PILOT COVER RPCDRL 21 7 REPLACMENT POWER HARNESS RECA131 a) 1111.411 8 VALVE J RGC3089 E as o Z v 9 PILOT RPA035 4,O. 4 . Optional Parts 10 PERFORATED ROCK TRAY RRTDRL36 15 ADJUSTABLE TRIM KIT 0-11/16" DRLT36 `� ili' 11 PILOT TUBING24" RPTA03 16 ADJUSTABLE TRIM KIT 1 1/2"-2" DRLT36-2 12 FUSE 3.SA REC1386 17 DELRAY ON/OFF REMOTE RX40 22 13 PROFLAME 2 BASIC CONTROL BOARD RGC3094 18 DELRAY THERMOSTATIC REMOTE RX60 4 PROFLAME 2 BOARD HARNESS REC3062 19 LP CONVERSION KIT GCA010 20 BASIC FAN KIT DRFK1 0 21 DELRAY PV WIRE HARNESS ECA136PV BLACK GLASS REcEI'.1ED 22 FASTENER REPAIR KIT RKIT01 26 BLACK GLASS KIT RBGDRL36 27 REAR BLACK GLASS RGL5115 0 ZB n/� n 28 SIDE BLACK GLASS RGL5116 26 03/24/2021 XG0226-042220 ASPEN 35 BUILDING DEPARTMENT Appendix DRL3613*I-2 FULL LOAD Exploded Parts N\1 \ED 1 .. . it ,:1 .6....,1 1 lii Itt l's- . iiii,\ o ' ,off 1 , \ )a 1\1 ,1111111' \\1\\-,' trnil . , m ® \gym ® 4 O r el In I z v o �o v Standard Parts 1 CEMENT BOARD CBSDRL36 22 2 SCREEN SCRIDRL36 I% 3 DOOR RDTDRL3613 Imo] 4 VALVE COVER RVBDRL3613 RBDRL3613 023 5 BURNER BLACK GLASS 6 PILOT COVER RPCDRL 7 REPLACEMENT BULB REC1546 0 0 VALVE RGC3089 29 9 PILOT RPA035 26 10 LEFT FAN REC1377DRL ® 11 RIGHT FAN REC1378DRL v -a s- 12 FUSE 3.5A REC1386 Z l�J d01. 13 BATTERY HOLDER(4) AF40BP Optional Parts 14 ON OFF SWITCH RECA015 20 ADJUSTABLE TRIM KIT 0-11/16" DRLT36 15 PROFLAME2 FULL CONTROL BOARD RGC3095 21 ADJUSTABLE TRIM KIT 1 1/2"-2" DRLT36-2 25 16 PILOT TUBING 24 RPTA03 22 WALL MOUNT PROFLAME2 REMOTE REC1493 17 PERFORATED ROCK TRAY RRTDRL36 23 LP CONVERSION KIT GCA010 18 POWER HARNESS RECA131 24 DELRAY PV WIRE HARNESS ECA136PV 19 PROFLAME2 BOARD HARNESS REC3062 25 FASTENER REPAIR KIT RKITO1 ,s 26 BLACK GLASS KIT 27 REAR BLACK GLASS RECEIVED 28 SIDE BLACK GLASS RGL5116�//�� // 29 REMOTE a 3/24/2O21 30 AIR FLOW BRACKET RAFBDRL3613 36 X4ggi220 BUILDING DEPARTMENT Appendix DRL4813*I BASIC Exploded Parts 0 C :ki 4 1 o\ ® o �_ ` 0 o CI — \ iliii,. ______. ILI.. \ 0 19 ,..,.. .,,, i ilishiI 0 li '' '''''''''''''''' ''''''' OM ® • 1k1)427. 0 0 20 0 ® m 17 ) 21--// BLACK GLASS i. I� :n- 28 28 .r m I -{� A 26 e�l 22 o 18 Z U Standard Parts aE )gn 1 CEMENT BOARD CBSDRL48 Z 0 mi 2 SCREEN RSCDRL4813 Optional Parts 3 DOOR RDTDRL4813 15 ADJUSTABLE TRIM KITO-11/16" DRLT48 4 VALVE COVER RVBDRL4813 16 ADJUSTABLE TRIM KIT11/2"-2" DRLT48-2 5 BURNER ASSEMBLY RBDRL4813 17 DELRAY ON/OFF REMOTE RX40 6 PILOT COVER RPCDRL 18 DELRAY THERMOSTATIC REMOTE RX60 7 REPLACMENT POWER HARNESS RECA131 19 LP CONVERSION KIT 20 BASIC FAN KIT GCA019 8 VALVE RGC3089 DRFK1 9 PILOT wRPA035 21 DELRAY PV WIRE HARNESS ECA136PV 10 PERFORATED ROCK TRAY RE/ Rf '�D 22 FASTENER REPAIR KIT RKITO1 I 1 PILOT TUBING 24" 26 BLACK GLASS KIT RBGDRL48 12 FUSE 3.5A REEC/1�38/� 27 REAR BLACK GLASS RGL5117 13 PROFLAME 2 BASIC CONTROL BOARDC 3/RFC�D74 2 0 21 28 SIDE BLACK GLASS RGL5116 14 PROFLAME 2 BOARD HARNESS REC3062 ASPEN37 ' `vPEN37 BUILDING DEPARTMENT Appendix DRL4813*I-2 FULL LOAD Exploded Parts 11% m 0 0 I © O 0 \ 0 " Ihk.ItUir, @ o m 0 1, 7iiiik t\ : , . BLACK GLASS ` NC zs s OD k''' a) v m �s z v° 21 Standard Parts 1 CEMENT BOARD CBSDRL48 O ��. 2 SCREEN SCRIDRL48 3 DOOR RDTDRL4813 ilimi O 4 VALVE COVER RVBDRL4813 El V- 5 BURNER RBDRL4813 6 PILOT COVER RPCDRL 01 — 7 REPLACEMENT BULB REC1546 — 8 VALVE RGC3089 O O 9 PILOT RPA035 0 10 LEFT FAN REC1377DRL 11 RIGHT FAN REC1378DRL 12 FUSE 3.5A REC1386 - 23 13 BATTERY HOLDER(4) AF40BP Z 0 14 ON OFF SWITCH ,l J RECA015 Optional Parts 15 PROFLAME2 FULL CONTROL BOARD RGC3095 20 ADJUSTABLE TRIM KIT 011/16" DRLT48 16 PILOT TUBING 24 RPTA03 21 ADJUSTABLE TRIM KIT 1 1/2"-2" DRLT48-2 17 PERFORATED ROCK TRAY RRTDRL48 22 WALL MOUNT PROFLAME2 REMOTE REC1493 24 18 POWER HARNESS RECA131 23 LP CONVERSION KIT GCA019 19 PROFLAME2 BOARD HARNESS REC3062 24 DELRAY PV WIRE HARNESS ECA136PV • 26 BLACK GLASS KIT RBGDRL48 25 FASTENER REPAIR KIT RKITO1 27 REAR BLACK GLASS RECEI\IED4 28 SIDE BLACK GLASS .00` 29 REMOTE RGC3063 'f '' 30 AIR FLOW BRACKET 0 3/ 7�2 0 21 25 QQ � 38 X4�26U2220 BUILDING DEPARTMENT Notes RECEIVED 03/24/2021 XG0226-042220 ASPEN„ BUILDING DEPARTMENT Installation & Maintenance Manual DeiRay Single Sided Gas Fireplace RECEIVED 03/24/2021 Ab%X,W zo BUILDING DEPARTMENT