Loading...
HomeMy WebLinkAboutFile Documents.134 E Bleeker St.0102-2020-BRES (40) Ic+A &Kumar Associates, Geotechnical Aland Materialss Engineers 5020 County Road 154 and Environmental Scientists Glenwood Springs,CO 81601 phone:(970)945-7988 fax: (970)945-8454 email:kaglenwood@kumarusa.com An Employee Owned Company www.kumarusa.com Office Locations: Denver(HQ),Parker,Colorado Springs,Fort Collins,Glenwood Springs,and Summit County,Colorado July 2, 2020 Eigelberger Architecture+Design Attn: Nick Chan 350 Market Street, Suite 309 Basalt, Colorado 81621 (nchan@eigelberger.com) Project No. 20-7-375 Subject: Summary Soils Report, Proposed Full Basement and Crawlspace Under Existing House, 134 East Bleeker Street, Aspen, Colorado Dear Nick: As requested, Kumar&Associates, Inc. is providing this summary soils report for preliminary design of foundations at the subject site. Access into the site with a drill rig is not practical at this time. Our recommendations are based on previous subsoil studies performed in the area as verbally requested via email on May 13, 2020 and amended to our agreement for geotechnical engineering services to you dated May 15, 2020. We have previously performed at least half a dozen subsoil studies within a block of the subject site. Our recommendations are based on the proposed construction and subsurface conditions previously encountered in the area. Proposed Construction: The proposed full basement over crawlspace will be placed below the existing residence. Cut depths are expected to range up to about 22 feet. Foundation loadings for this type of construction are assumed to be relatively light and typical of the proposed type of construction. Excavation shoring will be provided as needed to maintain cut slope stability. If building conditions or foundation loadings are significantly different from those described above, we should be notified to re-evaluate the recommendations presented in this report. Site Conditions: The site is relatively flat and occupied by an existing one and two story residence with mature landscaping. RECEIVED 09/03/2020 ASPEN BUILDING DEPARTMENT - 2 - Subsurface Conditions: The subsurface conditions encountered in this area typically consist of about 5 feet of gravel fill overlying relatively dense gravel alluvium. There can be layers of alluvial sand within the gravel. The gravel alluvium is expected to extend down at least 50 feet and groundwater is expected to be at least 50 feet below the site. The bearing soils at proposed cut depth are expected to be relatively dense, slightly silty, sandy gravel with cobbles and small boulders. Foundation Recommendations: Considering the subsoil conditions encountered in the area and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 3,000 psf for support of the proposed new foundation. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils and existing fill encountered at the foundation bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural gravel soils. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 42 inches below the exterior grade is typically used in this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 45 pcf for the on-site soil as backfill. The coefficient of friction of 0.50 can be used to resist sliding on the bottom of footings. An equivalent fluid unit weight of 425 pcf can be used to resist lateral loads on the sides of footings. Floor Slabs: The natural on-site soils, exclusive of fill and topsoil, are suitable to support lightly loaded slab-on-grade construction. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of free-draining gravel should be placed beneath basement level slabs to facilitate drainage. This material should consist of minus 2 inch aggregate with less than 50%passing the No. 4 sieve and less than 2%passing the No. 200 sieve. RECEIVED 09/03/2020 Kumar&Associates,Inc.® Project No. 20-7-375 i\SPEN BUILDING DEPARTMENT - 3 - All fill materials for support of floor slabs should be compacted to at least 95% of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on- site soils devoid of vegetation, topsoil and oversized rock. Underdrain System: Although free water is not expected to be encountered in the excavation, it has been our experience in the area that local perched groundwater can develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can also create a perched condition. We recommend below-grade construction, such as retaining walls, crawlspace and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. The drains should consist of perforated rigid drainpipe placed in the bottom of the wall backfill surrounded above the invert level with free-draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and sloped at a minimum 1/2%to a suitable outlet such as a drywell or sump and pump. Free-draining granular material used in the underdrain system should contain less than 2%passing the No. 200 sieve, less than 50%passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 11/2 feet deep. Percolation tests performed in this area indicate the natural gravel soils are relatively free draining. Surface Drainage: The NRCS mapping shows Type B soil for this area of Aspen. The following drainage precautions should be observed during construction and maintained at all times after the project has been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 98% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. Free-draining wall backfill should be capped with about 2 feet of the on-site, finer graded soils to reduce surface water infiltration. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a mininTE 1 E IVE D 09/03/2020 Kumar&Associates,Inc.® Project No. 20-7-375 i\SPEN BUILDING DEPARTMENT - 4 - slope of 16 inches in the first 10 feet in unpaved areas and a minimum slope of 21/2 inches in the first 10 feet in pavement and walkway areas. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. Limitations: This report is based on subsoil conditions previously encountered for nearby projects. We make no warranty either express or implied. The conclusions and recommendations submitted in this report are based upon our experience in the area. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. Variations in the subsurface conditions may not become evident until excavation is performed. This report has been prepared for the exclusive use by our client for preliminary design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should perform subsurface exploration for foundation design, provide continued consultation and monitor the implementation of our recommendations to verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. If you have any questions or if we may be of further assistance, please let us know. Respectfully Submitted, Kumar& Associates, Inc. ,(/ ( ' .. •�Y •'11, Daniel E. Hardin,P.E. • 24443 t • •Reviewed by: SLP r'r t'•..•N •./44".1 ,8/ONp_ DEH/ljf cc: Eigelberger Architecture—Hannah Hunt Moeller(hannahhunt(a,eigelberger.com) KL&A—Brett McElvain (bmcelvain@klaa.com) RECEIVED 0-910 31 L02 0 Kumar&Associates,Inc.® Project No. 20-7-375 ASPEN BUILDING DEPARTMENT