Loading...
HomeMy WebLinkAboutFile Documents.134 E Bleeker St.0102-2020-BRES (43) WELS Markup #2 134 E Bleeker St [1] IR- 134 Bleeker-IR 1.0 (5) �.. u.� a Page: [1] IR 134 Bleeker-IR 1.0 "`R"" "' �� Mr. Borgmann's QWEL certification in itself doesn't necessarily meet the WELS requirements(WELS Section 5.3.1 (h))for irrigation �" Author: rickma Date: 5/3/2021 12:03:11 PM designers. a••a• File Name: 90.Irrigation Plans.20210325.pdf Please provide more information about irrigation design credentials which specifically address the WELS Section above. HINES: - Certified Irrigation Designer (CID) Stamp and signature provided for the Permit Set and indicated on all Irrigation Sheets. Zone A Page: [1] IR- 134 Bleeker-IR 1.0 Irrigation valve A6 which serves medium turf via overhead irrigation method is not included in this worksheet. Revise to include this Author: rickma Date: 5/3/2021 12:17:57 PM zone. Irrigation valve A6 TOTAL which serves medium AVERAI File Name: 90.Irrigation Plans.20210325.pdf turf via overhead HINES: irrigation method is not *The on includedthis worksheet. Revise to Irrigation valve A6 zone has been added to the Hydrozone Water Budget Re include this zone. Calculation chart seen on Sheet IR - 1.0 with necessary revisions to the calculations. Page: [1] IR- 134 Bleeker-IR 1.0 e A10Aspen Medium The Hydrozone Plan, Sheet LO-04 indicates that valve A2 is medium water, not low. Revise water budget accordingly. e Al,A2 Low Author: rickma Date: 5/3/2021 11:58:02 AM HINES: :RAGE IRRIGATION WATER NEED-ALL ZONES*-In ga File Name: 90.Irrigation Plans.20210325.pdf e average must be less than aximum Applied Water Valve A2 water type and calculation revised to reflect medium requirement. Water The Hydrozone Plan,Sheet LO-04 indicates that valve A2 is medium budget revised accordingly on Sheet IR - 1.0. water,not low.Revise water budget accordingly. 676 194 Page: [1] IR- 134 Bleeker-IR 1.0 The hydrozone area indicated in this worksheet totals 3,238 Sq. Ft. not 2,412. Revise the total hydrozone area in budget. Author: rickma lat 784 Date: 5/3/2021 12:28:02 PM 3 File Name: 90.Irrigation Plans.20210325.pdf HINES: Water Budget worksheet revised reflecting all required changes of this permit The hydrozone area indited in this wo totals3238 Sq.Ftrntae' review. Worksheet totals have been revised accordingly to match the new square 2,412.Revise a i total RECEIVED hydr°=°ne area in budget foot total of 3,236 sq. ft. seen on the Water Budget Calculation Chart on Sheet IR - 1.0 07/23/2021 ASPEN BUILDING DEPARTMENT Page: [1] IR- 134 Bleeker-IR 1.0 Hydrozone Author: rickma Festuca arundinacea-Tall Fescue Turf sod is rated as a medium water need species.The Hydrozone Plan, Sheet LO-04 indicates Festuca arundinacea- that all turf areas are rated as medium as well. Revise the water budget calculations accordingly. Tall Fescue Turf sod Date: 5/3/2021 12:16:16 PM is rated as a medium Zone A5,A8 ROW water need species. Turf 7 File Name: 90.Irrigation Plans.20210325.pdf The Hydrozone Plan, Zo Turf Sheet LO-04 indicates HINES: that all turf areas are OW Turf rated as medium as Zone Turf well.Revise the Zone A9 ROW Tree All associated areas utilizing Festuca arundinacea - Tall Fescue Turf Sod, have water budget calculations Zone A1 Aspen accordingly. Zone Al,A2 been revised as a medium water requirement species in the plans (Sheets L0-04 -�--r and IR - 1.0, 2.0) and within the water budget calculations indicated on IR 1.0. 5 (1) HYDROZONE LEGEND Page: 5 The irrigation design plans and the water budget prepared by Hines Inc.do not correspond with this hydrozone plan. Please Author: rickma coordinate with the irrigation designer in revising all plans and water budget calculations for consistency. Mao,a..,aa,aa Date: 5/3/2021 12:23:04 PM File Name: 90.Landscape Plans.20210324(2).pdf me Irtlgaaoa tlealga plaoa atl me wafer bmgai prepares D W. by Hlnea Inc.da not mrteapontl wiN tbla bytlmzone plan. Please cooMlnate wllb Me Irngatlon tlealgner In revlsing all plans antl water butlget calculatlans for conalatency. Landscape Sheet LO-04 - Hydrozone Plan has been revised to correspond with revised Irrigation Hydrozone calculations and plans per this permit review. HINES: Additional Note - Current water budget calculations include Right-of-way irrigation, and are noted on Sheet IR 1.0. Site Irrigation needs are calculated to meet the 7.5 gal/sq.ft./season WELS requirement. RECEIVED 07/23/2021 ASPEN BUILDING DEPARTMENT