Loading...
HomeMy WebLinkAboutFile Documents.1265 Mountain View Dr.0069-2020-BCHO (5)BEDROOM #4 010 MECHANICAL 009 BEDROOM #5 014 BATH #4 011 BATH #2 005 I.T. 006 BEDROOM #3 007 LAUNDRY 013 BATH #3 008 SD SD SD SD SD SD 3'-6" LI N E N HA N G D R Y WD W/D CHUTE 2' - 0 " 9' - 0 " 5' - 1 1 1 2" 11'-11"5'-6" 5'-9" VERIFY 12'-9" 6' - 4 1 2" push foundation out to allow for stud framing at perimeter of bump-out 01 02 03 05 07 08 09 10 11 12 13 14 005 A 004 A 006 A 016 A 014 A 009 A 015 A 010 A013 A 010 C 06 A 007 008 A 04 003 A 012 A 011 A B 007 BEDROOM #2 004 REC. ROOM 001 hallway 002 STORAGE 003 WALK-IN 012 BATH #5 015HALLWAY 017 WALK-IN 016 CRAWL SPACE 018 4'-0" 3'-0" 2'-4" 5'-6"3'-10"13'-3" 22'-7" SCALE: SHEET NO. wmr AS P E N , C O L O R A D O 12 6 5 M O U N T A I N V I E W D R I V E PR I V A T E R E S I D E N C E CO DETECTORS TO BE INSTALLED PER CURRENT CODE DATE REVISION TITLE : C ALL RIGHTS, IDEAS, ARRANGEMENTS AND PLANS INDICATED IN THESE DRAWINGS ARE THE PROPERTY OF HANCOX GROUP INC. AND SHALL NOT BE USED BY ANY OTHER PERSON FOR ANY USE WITHOUT WRITTEN PERMISSION. COPYRIGHT, 2020 ALL RIGHTS RESERVED PLAN NORTH 10-4-19 CONCEPT HA N C O X gr o u p ar c h i t e c t u r e a n d p l a n n i n g 31 4 s o p r i s c i r c l e ba s a l t , c o l o r a d o 8 1 6 2 1 97 0 - 6 1 8 - 5 5 8 8 IN F O @ H A N C O X G R O U P . C O M TOPO. 7,999.5' = ARCH. 100'-0" 03-02-20 BLDG. DEPT SUBMITTAL 03-28-20 BLDG. DEPT SUBMITTAL REVISED 09-10-20 ORDER SUBMITTAL CHANGE A2.03 1/4" = 1'-0" LOWER LEVEL FLOOR PLAN 09/24/2020 K-5714-GUNDERSCOREBATHACRYLIC 3' - 0 " 3'-0" 11'-11" 5' - 1 1 1 2" DW SINK RE F / F R Z RA N G E DW PA N T R Y W T SI N K mi c r o DN UP DN UP CHUTE LI N E N 2' - 0 " 2' - 0 " 3' - 5 " 101 A 16 TRANSOM 1718 19 20 21 22 23 24 25 26 27 28 29 32 33 34 39 40 41 42 434415 101 B 103 A 102 A 111 A 111 B 112 A 007 C 106 A 115 A 116 A 113 A 117 A 108 A 107 A 30 TRANSOM 31 TRANSOM 36 37 38 116 A 35 BEDROOM #1 111 BATH #1 112 ENTRY PORCH 116 ENTRY FOYER 101 GARAGE 107 KITCHEN 104 MUDROOM 105 DINING AREA 108 MASTER BED 114 WALK-IN 117 MASTER ANTE 113 MASTER BATH 115 W.C. 116 PWDR 103 NEW DECK AREA 017FAMILY ROOM 110 LIVING AREA 109 BAR 102 BACK ENTRY 106 WALK-IN 3'-21 2"3'-0"3'-21 2" 4' - 1 1 2" 6' - 0 " 3' - 6 " 31 ' - 8 " 11 ' - 7 1 2" v e r i f y 17'-1" 7'-0" 7' - 6 1 2" 3' - 8 " 2' - 5 1 2" 6'-101 2"7' - 6 1 2" 22'-01 2" 3' - 6 " 3' - 8 " 31'-6" 19 ' - 6 " 8'-6"7'-0"8'-6" 3' - 0 " 4'-51 2"9'-01 2" 5' - 4 " 8" 8" 8" 8' - 0 " 6"8"8"8"14'-9"8"8"8" 8' - 6 " 7'-4"19'-9" 3' - 2 " 8' - 2 1 2" 17 ' - 7 " 8' - 1 0 " 1' - 7 " 4' - 8 1 2" 5' - 3 1 2" 3' - 6 " 4'-51 2"15'-1"4'-51 2" 8' - 0 " 1'-2"1'-3" 15'-31 2" 10 ' - 0 " 9' - 1 0 " 10 ' - 7 1 2" 7' - 1 1 2" 4'-61 4"4'-11 2"7'-31 2"4'-11"3'-01 2"6'-10" 5'-91 2"5'-9" 5'-3"6'-31 2" 2'-71 2"3'-0" 4" 3' - 5 " 6' - 0 " 3' - 5 " 3'-0" 4' - 3 1 4" 5' - 9 " 3'-9" 8" 6'-51 2" 2' - 1 0 1 2" 7' - 5 1 2" 9' - 0 " SD SD SD SD SD SCALE: SHEET NO. wmr AS P E N , C O L O R A D O 12 6 5 M O U N T A I N V I E W D R I V E PR I V A T E R E S I D E N C E CO DETECTORS TO BE INSTALLED PER CURRENT CODE DATE REVISION TITLE : C ALL RIGHTS, IDEAS, ARRANGEMENTS AND PLANS INDICATED IN THESE DRAWINGS ARE THE PROPERTY OF HANCOX GROUP INC. AND SHALL NOT BE USED BY ANY OTHER PERSON FOR ANY USE WITHOUT WRITTEN PERMISSION. COPYRIGHT, 2020 ALL RIGHTS RESERVED PLAN NORTH 10-4-19 CONCEPT HA N C O X gr o u p ar c h i t e c t u r e a n d p l a n n i n g 31 4 s o p r i s c i r c l e ba s a l t , c o l o r a d o 8 1 6 2 1 97 0 - 6 1 8 - 5 5 8 8 IN F O @ H A N C O X G R O U P . C O M TOPO. 7,999.5' = ARCH. 100'-0" 03-02-20 BLDG. DEPT SUBMITTAL 03-28-20 BLDG. DEPT SUBMITTAL REVISED 09-10-20 ORDER SUBMITTAL CHANGE A2.04 1/4"=1'-0" MAIN LEVEL FLOOR PLAN EXTERIOR LIGHTING NOTE: ALL EXTERIOR LIGHTING SHALL COMPLY WITH THE ASPEN LIGHTING CODE. ALL LIGHTS WILL BE DOWN LIT AND THE SOURCE OF LIGHT SHALL BE SHIELDED. SEE ATTACHED CUT SHEET FOR LIGHT. 09/24/2020 T.O. PLYWD.@ MAIN EL.= 100'-0" T.O. PLYWD.@ MASTER EL.= 104'-7 1/2" T.O. SLAB @ LOWER EL.= 95'-6" T.O. PLYWD.@ FAMILY EL.= 104'-7 1/2" 040506 27 26 METAL EDGE CORNER TYP. 7' - 0 " T.O. PLYWD.@ MAIN EL.= 100'-0" T.O. PLYWD.@ MASTER EL.= 104'-7 1/2" T.O. SLAB @ LOWER EL.= 95'-6" 0910111213 36 20 37 36 36 7' - 6 " 5' - 6 " 2' - 0 " 2'-6" 5' - 0 " 8' - 0 " 8' - 0 " 3' - 6 " 5'-0" 7' - 0 " 2'-6" 8' - 0 " 7' - 6 " 5'-6"5'-6" 5' - 6 " 2' - 0 " 5'-0" SCALE: SHEET NO. wmr AS P E N , C O L O R A D O 12 6 5 M O U N T A I N V I E W D R I V E PR I V A T E R E S I D E N C E CO DETECTORS TO BE INSTALLED PER CURRENT CODE DATE REVISION TITLE : C ALL RIGHTS, IDEAS, ARRANGEMENTS AND PLANS INDICATED IN THESE DRAWINGS ARE THE PROPERTY OF HANCOX GROUP INC. AND SHALL NOT BE USED BY ANY OTHER PERSON FOR ANY USE WITHOUT WRITTEN PERMISSION. COPYRIGHT, 2020 ALL RIGHTS RESERVED PLAN NORTH 10-4-19 CONCEPT HA N C O X gr o u p ar c h i t e c t u r e a n d p l a n n i n g 31 4 s o p r i s c i r c l e ba s a l t , c o l o r a d o 8 1 6 2 1 97 0 - 6 1 8 - 5 5 8 8 IN F O @ H A N C O X G R O U P . C O M TOPO. 7,999.5' = ARCH. 100'-0" 03-02-20 BLDG. DEPT SUBMITTAL 03-28-20 BLDG. DEPT SUBMITTAL REVISED A3.01a 1/4"=1'-0" NORTH AND WEST SIDE ALTERNATIVE ELEVATIONS 09/24/2020