HomeMy WebLinkAboutFile Documents.285 Pfister Dr.0028-2020-BRES (2)1908 SMITH Division Name Area Image Item Tag Reference Manufacturer Model Name Model #Finish / Color Dimensions Docs Area: Lower Level / Media Room 10 Specialties Lower Level / Media Room Fireplace FP-001 Montigo Distinction D7215 Glass Opening: 73- 7/8" x 15-1/2" xg0222_montigo_disti nction_instructions 01/03/2020 montigomodernsingles idedresidentialfireplac ed7215specsheet 01/03/2020 xb2213montigofireplac esdistinctionbrochure 01/03/2020 Area: Main Level / Great Room 10 Specialties Main Level / Great Room Fireplace FP-101 Flare Fireplaces Flare Double Corner Fireplace Flare-DC-80 Glass Opening: 82- 9/16" x 16"; Specification Files framingdcmetal 01/03/2020 framingdcwood 01/03/2020 dimensionsdc80 01/03/2020 install_manual 01/03/2020 partsdc 01/03/2020 catalog 01/03/2020 doublecorner 01/03/2020 specsdc80 01/03/2020 Area: Main Level / Bedroom 1 10 Specialties Main Level / Bedroom 1 Fireplace FP-100 Regency Regency City Series Chicago Corner 40LE Gas Fireplace Glass Opening: 42-15/16" x 15-1/16" 2019cityseriesbrochure newversion_lowres 01/31/2020 regency_city_series__ specsheetcc40le11_low res 01/31/2020 regency_city_series_m anual__citycc_11_9199 28c_lowres 01/31/2020 Page 1 of 2 03/30/2020 Area: Upper Level / Master Bedroom 10 Specialties Upper Level / Master Bedroom Fireplace FP-100 Regency Regency City Series Chicago Corner 40LE Gas Fireplace Glass Opening: 42-15/16" x 15-1/16" 2019cityseriesbrochure newversion_lowres 01/31/2020 regency_city_series__ specsheetcc40le11_low res 01/31/2020 regency_city_series_m anual__citycc_11_9199 28c_lowres 01/31/2020 Division Name Area Image Item Tag Reference Manufacturer Model Name Model #Finish / Color Dimensions Docs Page 2 of 2 03/30/2020 START_PAGE FP-001 LOWER LEVEL / MEDIA ROOM Division Name:10 Specialties QTY:1 Manufacturer:Montigo Model Name:Distinction Model #:D7215 Dimensions:Glass Opening: 73-7/8" x 15-1/2" Page 1 of 403/30/2020 Distinction PART ACTUAL FRAMING FRONT WIDTH 87⅞’’95¾’’ BACK WIDTH 87⅞’’95¾’’ HEIGHT 43⅛’’59 ⅜’’ DEPTH 18 ⅜’’18 ½’’ VIEWING AREA 73⅞’’ X 15½’’N/A LINEAR GAS FIREPLACE DIMENSIONS SPEC SHEET D7215 TECHNICAL SPECIFICATIONS D7215 standard with: • Full load Proflame2 control system and full function remote control • 57,000 BTU/HR NG or LP Montigo 4TH generation linear concealed burner • 30% turn down gas valve with steppermotor • Ceramic glass door with fl ush safety screen • Quiet circulating fans with remote speed adjustment • Ceramic glass reflective liner kit • Multicolor LED uplighting with remote control • Ice fireglass media • Metal header and cementboard facing D7215 Options: • Cool Wall Advantage TV kit • Cool Wall Advantage side discharge kit • Speckled stones, driftwood logset A B C C D G H J I K LFF E D7215 SINGLE SIDED DIMENSIONS A B C D E F G H I J K L 87⁄18⁄7 6 ¾ 95⁄73⁄17 15½ 5½ 2⁄13⁄10⁄41 FEATURES • 18½” Framing Depth • Montigo 4th generation 57,000 BTU/HR concealed linear burner • Standard 5/8 direct vent • Field convertible to propane with optional conversion kit • Heat distribution kits for secondary heating 03/30/2020 The perfect combination of performance and design FRAMING SPECIFICATIONS SPECIFICATIONS • Sides: 4” • Back: ⅛” • Top : 18 ⅜’’ • Floor: 0” • Facing Material: Cement board (Supplied) Distinction LINEAR GAS FIREPLACE SPEC SHEET D7215 E A B D 1 3 2C 206 8 18 " 1680 66 18 " 206 8 18 " 625 24 58 " 419 16 12 " 330 13" 1375 54 18 " F F K G I H J 4 1 Floor structure 2 Metal header 3 Fireplace platform 4 Concrete board D7215 SINGLE SIDED DIMENSIONS A B C D E F G H I J K 59⁄2¼ 41⁄9 5 ¾ 18½ 10⁄76⁄33⁄17⁄12⁄63⁄ BTU Efficiency Unit Code High Low P.4. 1-02 Steady state D7215NI 57,000 39,000 > 63%> 70% D7215LI 57,000 46,000 > 63%> 70% 03/30/2020 START_PAGE FP-101 MAIN LEVEL / GREAT ROOM Division Name:10 Specialties QTY:1 Manufacturer:Flare Fireplaces Model Name:Flare Double Corner Fireplace Model #:Flare-DC-80 Dimensions:Glass Opening: 82-9/16" x 16"; Specification Files Page 2 of 403/30/2020 SPEC SHEET : DC-80 _________________________________________________________________________________________________________ DIRECT VENT FLARE DC-80 FLARE FRAMELESS MODERN DOUBLE CORNER FIREPLACE (SS) Safety Screen / (DG) Double Glass SUBJECT DETAILS Gas Type Natural Gas (NG) or Liquid Propane (LP) Safety Standard CSA File # 263124 - ANSI Z21.88 - CSA 2.33 Operation Mertix GV60 Honeywell SIT Electrical Requirements 110 Volts, 15 Amps (DEDICATED POWER RECOMMENDED) Glass Height 16" Optional RGB LED System Optional Multi-Colored Interior RGB LED Lighting System Optional Power Vent System End-Of-Line Vertical End-Of-Line Horizontal Inline Optional Double Glass Optional Cooler Touch Double Glass Weight IN CRATE NO CRATE 507 (SS) / 556 lbs (DG) 406 (SS) / 443 lbs (DG) Cool Wall Tech Allows for TV or art above your Flare Burners Multi-Row Stainless Steel Burner Interior Media Options FIRE GLASS 1/2" & 1/4" CERAMIC LOGS EMBERS FIRE BEADS CERAMIC BRANCHES CERAMIC STONES ZIRCON DIAMONDS CERAMIC BIRCHWOOD CERAMIC STONE BALLS Product Specifications • The Flare Fireplace is certified for use with either Natural Gas (NG) or Propane (LP) • The Flare Fireplace operates with a direct vent, balanced flue system. A direct vent gas fireplace is room-sealed using ceramic glass. • The Flare Fireplace use’s double pipe vent flue to pull in fresh air from outside & release exhaust gases to the outside. Clearances to combustible materials MUST be maintained. Refer to Installation Manual for clearance distances. • The Flare Fireplace must be properly connected to a venting system. • The Flare Fireplace must be installed according to requirements as presented in the Installation Manual, as well as complying with all local codes. If no codes exist, then the current CSA installation code must be followed. 03/30/2020 SPEC SHEET : DC-80 _________________________________________________________________________________________________________ Gas Pressure & Power Output GV-60 GAS INLET PRESSURE MANIFOLD PRESSURE MAX BTU OUTPUT ORIFICE SIZE BURNER SIZE (inches) MIN. MAX. Burner 1 Burner 2 Burner 3 Burner 1 Burner 2 Burner 3 NG 7.0 " WC 8.0 " WC 3.09 55,700 480 1200 480 14 40 14 LP 10.0 " WC 11.0 " WC 6.38 46,000 160 380 160 SIT GAS INLET PRESSURE MANIFOLD PRESSURE MAX BTU OUTPUT ORIFICE SIZE BURNER SIZE (inches) MIN. MAX. Burner 1 Burner 2 Burner 3 Burner 1 Burner 2 Burner 3 NG 7.2 " WC 8.2 " WC 3.5 55,000 420 1000 420 14 40 14 LP 10.0 " WC 11.0 " WC 9.5 49,000 140 320 140 HONEYWELL GAS INLET PRESSURE MANIFOLD PRESSURE MAX BTU OUTPUT ORIFICE SIZE BURNER SIZE (inches) MIN. MAX. Burner 1 Burner 2 Burner 3 Burner 1 Burner 2 Burner 3 NG 7.0 " WC 8.0 " WC 2.61 55,700 480 1200 480 14 40 14 LP 10.0 " WC 11.0 " WC 5.46 46,000 160 380 160 For more information on Flare or our amazing features please visit: https://www.flarefireplaces.com Parts Included: • Flare Fireplace • Ceramic Glass Panel(s) • Invisible Mesh Safety Screen • Option of “Classic” Media • Complete Electronic ignition Pilot Assembly • Spare Parts Kit • Adjustable Telescopic Legs & Mounting Brackets • AC Power Supply, Remote Control, & Wall Switch Optional Features & Accessories: • Reflective Black Ceramic Back • Summer Kit Heat Control System • Home Automation Integration (New & Existing) • Wi-Fi Connectivity (myfire Smart App) • Battery Backup (Screen Units Only) Approved Venting Specification: • DuraVent • ICC • Natural Draft Pipe Size: • Power Vented Pipe Size: 3x5 5x8 03/30/2020 START_PAGE FP-100 MAIN LEVEL / BEDROOM 1 Division Name:10 Specialties QTY:1 Manufacturer:Regency Model Name:Regency City Series Model #:Chicago Corner 40LE Gas Fireplace Dimensions:Glass Opening: 42-15/16" x 15-1/16" Rep / Contact:Patrick Murtagh 970 319-7642 Page 3 of 403/30/2020 START_PAGE FP-100 UPPER LEVEL / MASTER BEDROOM Division Name:10 Specialties QTY:1 Manufacturer:Regency Model Name:Regency City Series Model #:Chicago Corner 40LE Gas Fireplace Dimensions:Glass Opening: 42-15/16" x 15-1/16" Rep / Contact:Patrick Murtagh 970 319-7642 Page 4 of 403/30/2020 City Series City Series CC40LE Gas Fireplace Model CC40LE-NG11 CC40LE-LP11 Fuel Type Natural Gas Propane Minimum Supply Pressure 5” W.C. (1.25 kPa) 11” W.C. (2.73 kPa) Manifold Pressure - High 3.8” W.C. (0.94 kPa) 10.5” W.C. (2.62 kPa) Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa) Orifice Size -Altitude 0-4500 ft.#42 DMS #53 DMS Minimum Input Altitude 0-4500 ft. (0-1372m) 15,500 BTU/h (4.54 kW) 15,500 BTU/h (4.54 kW) Maximum Input Altitude 0-4500 ft. (0-1372m) 28,500 BTU/h (8.33 kW) 28,500 BTU/h (8.33 kW) Vent Sizing 4” Inner / 6-5/8” Outer 4” Inner / 6-5/8” Outer CSA P.4.1 55.23%56.06% 25 14 " 64 3 m m 33 316 " 84 2 m m 37 18 " 94 3 m m 42 78 " 1089mm 43 58 " 1109mm 10 14 " 26 1 m m 15 116 " 38 2 m m 7 78 " 20 0 m m 14 34 " 375mm 34 38 " 87 3 m m 18 1116 " 475mm 17 58 " 449mm 6 34 " 172mm 4" 102mm 48" 1219mm 23 18 " 587mm 24 14 " 616mm 47 38 " 1203mm 03/30/2020 City Series CC40LE-11 Gas Fireplace CLEARANCES CC40LE Flue Clearances to Combustibles Horizontal - Top 3" Horizontal - Side 2" Horizontal - Bottom 2" Vertical 2" Passing through wall/ floor/ceiling - when firestop is used. 1-1/2" Caution Requirements The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction. WARNINGFire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Top View Alcove The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details. *A minimum of 120 square inches of open area, not lower than 3" from top of enclosure, required for all installations. H I A E B C G D F D F CC40 UNIT Clearance Dimension Measured From: A: Mantel Height (min.)**Top of Fireplace Opening B: Opening Height 15-1/16" (382mm) Bottom/Top of Fireplace Opening C: From Floor Min. 0" Bottom of Fireplace Opening D: Sidewall (on one side)Min. 36" (914mm) Side of Fireplace Opening E: Mantel Depth (Max.)**Front of Fireplace Opening F: Alcove Depth Min. 36" (914mm) Front of Fireplace Opening G: Convection Air Outlet *Top of Enclosure H: Convection Air Outlet Opening Offset 0-3" (76mm) Max. offset from top of chase enclosure I: Chase Enclosure (Min.)63" (1600mm) From Base of Unit J: Clearance to Sprinkler Head (Min.) 36" (914mm) Perpendicular from chase grill Hearth 0"No hearth required ** See mantel clearances chart in this guide. L Chase grill Sprinkler Side view J 03/30/2020 City Series CC40LE-11 Gas Fireplace CLEARANCES CC40LE Low framing with vents in front/sides or top Full framing with low vents in front or sides Floor to ceiling with top opening Full framing with vents in front or sides Chase enclosed H E B I H G G E G B H I Fl oor to ceiling with top op H E B I H G G E G G G H B I Low framing with vents 03/30/2020 City Series CC40LE-11 Gas Fireplace FRAMING DIMENSIONS CC40LE NOTE: Framing may be constructed of combustible material (ie. 2 x 4) and does not require steel studs. Note: A combined minimum of 120 square inches of open area is required for the convection air outlet to cool the enclosure. Ensure clearances for Convection Air Outlets are met. See clearances CC40LE (in the installation manual) as there are different methods as to how this can be achieved. Note: This appliance must be installed on a level and solid surface such as a plywood floor which must be the full width and depth of the appliance. Framing Dimensions Description CC40LE A Framing Height 37-3/8” (949mm) B Framing Width 48-1/4" (1226mm) C Framing Depth 19" (483mm) D Unit Base to Top Enclosure (Min.)63"(1600mm) G Vent Centerline Height 56-1/4" (1429mm) NOTE: Unit cannot be load-bearing. All finishing materials must be supported by the framing. Maximum material dimensions 2" x 4" for Header studs (installed on edge and flat) 03/30/2020 City Series CC40LE-11 Gas Fireplace MANTEL CLEARANCES CC40LE Combustible mantel clearances from top of front facing are shown in the diagram on the right. WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified. Finishing Instructions It is important to follow the framing and finishing instructions to ensure proper placement of fireplace into the surrounding framing/finishing materials. Wall board materials 1/2 in. thick are specified in this installation manual to properly align with the optional finishing methods offered with this appliance. The CC40LE/CC40RE may be finished to the appliance opening with 1/2 inch thick drywall. • Ensure that the back and side clearances are maintained. WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Inadequate air space could cause overheating and fire. DO NOT use screws more than 3/4 inch in length on the lower access cover panel. Longer screws may penetrate gas line or damage valve or electrical components. Note: It is acceptable to use a high temperature silicone sealant to adhere drywall to lower access cover panel. The appliance is designed to be used with 1/2 in. wall sheathing materials such as drywall, plywood, wood composites, or non-combustible materials. Thicker materials may be used. Refer to facing and finishing details in the installation manual. Facing Material • Facing and/or finishing materials must never overhang into the glass opening. • Facing materials may be combustible or non-combustible. WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in the installation manual. Overlapping materials could ignite and will interfere with proper operation. PAINTING If desired finishing includes a painted wall, 100% acrylic latex, oil-based or standard acrylic paints may be used. Follow paint manufacturer’s instructions for paint and primer application. WALL BOARD/DRYWALL INSTALLATION CC40LE 212 6 4810 0 14 9" 15-1/16” 10 20 26 Topof Fireplace Opening 12" (305mm) 1/2" Drywall, wood, wood panel, etc. 5-1/8" To Bottom of Fireplace Opening 03/30/2020 53 City Series FRAMING AND FINISHING INSET INSTALLATIONS CC40LE 1. Frame in the enclosure for the unit with framing material Note: When constructing the framed opening ensure there is sufficient access to install the gas lines,electrical. Also the wiring harness must be wall mounted using the receptacle provided with the appliance. The wiring harness will be located on the right hand side of the appliance if facing the unit from the front. This must be done prior to any finishing. 2. For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.) WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems including, but not limited to: excessive condensation on glass doors, poor flame package, carbon, blue flames etc. These are not product related issues. 3. The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances" section. Combustible materials can be laid against the side and back standoffs and the stove base. 4. Combustible material (drywall,wood,wood panels, etc.) may be brought up to this appliance (top,bottom and sides) 5. Ensure that the material being used does not encroach anywhere in the area of the glass. This would cause dangerous operating conditions. 6. This appliance comes with a 1/2" lip at top, sides and bottom to hide the ends of the drywall. The 1/2" side and bottom, front and bottom side lips supplied with the appliance can alternatively be removed and replaced with J Style Trim or Metal Corner Bead purchased at your local hardware store to cover cut/exposed edges of the combustible facing material or any other finishing materials being used. Six (6) screws secure the bottom front lip. Two (2) secure the bottom side lips and 2 secure the side if deciding to remove these. These will be hidden so the outer panels (if installed) will need to be removed to access the screws. See outer panel removal in the installation manual. 7. This appliance can also be recessed (using combustible materials) with a hearth in front of the appliance. This can also extend to the top. See below for details. 8. The wall behind the unit must be closed off. Note: an offset screwdriver is provided with the appliance for ease of removal/installation. CC40LE-11 Gas Fireplace 03/30/2020 City Series CC40LE-11 Gas Fireplace TV RECESSED INTO WALL- TYPICAL INSTALLS MAXIMUM TV RECESS TV FLUSH WITH HEARTH Max. 2 x 4 stud Max. 2 x 4 stud CB40 Typical Installs MAXIMUM TV RECESS FLUSH TV WITH HEARTH 5/8”4 maximum TV recess using 1/2” drywall Flush wall TV recess using 1/2" drywall Max 36” Hearth 1/8Max 5 ” Mantle 5/8Max 4 ” TV recess with drywall up against unit Max 3” To Top of Enclosure 2120in min Chase vent opening Header Stud 15 . 5 ” mi n 12 ” m i n Screws must not penetrate unit more than 1/2” . Adhere to “No Screw” zones painted on unit. Glue can be used as an alternative. Max 3” To Top of Enclosure 2120in min Chase vent opening Max. 2 x 4 stud Max. 2 x 4 stud CB40 Typical Installs MAXIMUM TV RECESS FLUSH TV WITH HEARTH 5/8”4 maximum TV recess using 1/2” drywall Flush wall TV recess using 1/2" drywall Max 36” Hearth 1/8Max 5 ” Mantle 5/8Max 4 ” TV recess with drywall up against unit Max 3” To Top of Enclosure 2120in min Chase vent opening Header Stud 15 . 5 ” mi n 12 ” m i n Screws must not penetrate unit more than 1/2” . Adhere to “No Screw” zones painted on unit. Glue can be used as an alternative. Max 3” To Top of Enclosure 2120in min Chase vent opening 03/30/2020 City Series CC40LE-11 Gas Fireplace VENTING INTRODUCTION The CC40LE uses the “balanced flue” technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney. Note: These flue pipes must not be connected to any other appliance. The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use a separate vent system. Common vent systems are prohibited. VENTING ARRANGEMENT FOR HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o (two 45o elbows equal one 90o elbow). Note: When using rigid vent pipe systems, the rigid pipe adaptor (Part# 510-994) must be used in all applications. •Maintain clearances to combustibles as listed in "Clearances" section •Horizontal vent must be supported every 3 feet. •Firestops are required at each floor level and whenever passing through a wall. •A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. •Flex system can only be used up to 10 feet - otherwise rigid venting must be used. VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 0 Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 2 if required. NOTE: A minimum of 1' (305mm) vertical off the top of the unit is required before any horizontal runs can start. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet. If longer runs are required, rigid pipe must be used. 56-1/4” (1429mm) 03/30/2020 City Series CC40LE-11 Gas Fireplace HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" The diagrams below show examples of horizontal termination arrangements using one, two, or three 90o elbows (two 45o elbows equal one 90o elbow) 1. A maximum of three–90 o elbows are permitted. 2. Minimum distance between elbows is 1 ft. (305mm). •Maintain clearances to combustibles as listed in the “Clearances” section. •Horizontal vent must be supported every 3 feet. •Firestops are required at each floor level and whenever passing through a wall. •Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems. •A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. •Flex system can only be used up to 10 feet - otherwise rigid venting must be used. HORIZONTAL VENTING WITH TWO (2) 90O ELBOWS HORIZONTAL VENTING WITH THREE (3) 90O ELBOWS H H1 V One 90o elbow = Two 45o elbows. Option V H + H1 With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal. Please note minimum 1 foot between 90o elbows is required. A) 1' Min. 2' Max. B) 2' Min. 4' Max. C) 3' Min. 5' Max. D) 4' Min. 6' Max. E) 5' Min. 7' Max. F) 6' Min. 8' Max. Restrictor Set 0 - Factory Setting One 90o elbow = Two 45o elbows. Option V H V + V1 H + H1 With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal. Please note min. 1 foot between 90o elbows is required. A) 1' Min. 1' Max. 2' Min. 2' Max. B) 1' Min. 2' Max. 3' Min. 3' Max. C) 2' Min. 2' Max. 5' Min. 4' Max. D) 3' Min. 2' Max. 7' Min. 5' Max. E) 4' Min. 3 Max. 9' Min. 6' Max. F) 5' Min. 4' Max. 10' Min. 7' Max. G) 6' Min. 5' Max. 11' Min. 8' Max. H) 7' Min. 6' Max. 12' Min. 9' Max. Restrictor Set 0 - Factory Setting 03/30/2020 City Series CC40LE-11 Gas Fireplace VENTING ARRANGEMENT FOR VERTICAL TERMINATIONS Vertical venting with straight vertical venting and or with a maximum of two (2) 90o Elbows (1–90o = 2–45o) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with Rigid Pipe Venting Systems. • Two–45 o elbows equal to one 90o elbow. • Vent must be supported at offsets. •Minimum distance between elbows is 1 ft. (305mm). •Maintain clearances to combustibles as listed in the "Clearances" section. •Horizontal vent must be supported every 3 feet. •Firestops are required at each floor level and whenever passing through a wall. •Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems. •Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 through to Set 3 if required. Ma x i m u m : 3 7 f t . ( 1 1 . 2 m ) Mi n i m u m 8’ 6 ” ( 2 . 6 m ) Mi n . 5 6 - 1 / 4 ” (1 4 2 9 m m ) Minimum length of pipe between elbows 12” (305mm) Ma x i m u m : 2 7 f t . ( 8 . 2 m ) 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 Ve r t i c a l H e i g h t ( F e e t ) 32 34 36 38 6 8 Horizontal (Feet) 20 4 10 12 16 1814 20 Vent Restrictor on Set 2 Vent Restrictor on Set 3 Vent Restrictor on Set 1 03/30/2020 City Series CC40LE-11 Gas Fireplace VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" •Two 45o elbows equal to one 90o elbow. Maximum of six 45o elbows allowed. •Vent must be supported at offsets. •Minimum distance between elbows is 1 ft. (305mm). •Maintain clearances to combustibles as listed in the "Clearances" section. •Horizontal vent must be supported every 3 feet. •Firestops are required at each floor level and whenever passing through a wall. •Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems. Vertical Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows. VH1H V1 Option V H + H1 V + V1 With these options, max. total pipe length is 30 feet with min. of 10 feet total vertical and max. 8 feet total horizontal. Please note min. 1 foot between 90o elbows is required. A) 1' Min. 2' Max 3' Min. B) 2' Min. 3' Max 4' Min. C) 3' Min. 4' Max 6' Min. D) 4' Min. 5' Max 7' Min. E) 5' Min. 6' Max 8' Min. F) 6' Min. 7' Max 9' Min. G) 7' Min. 8' Max 10' Min. Lengths do not include elbow indicated 03/30/2020