Several of the Kolbe windows
listed exceed the maximum .28
U-factor per 2015 IECC Table
R402.1.2 as amended by
Ordinance 40, 2016. Provide an
area-weighted average per
R402.3.1 or REScheck with UA
tradeoff per R402.1.5, or revise
windows as needed.
Verify that all windows and doors
will have NFRC labels on them
stating U-factor or provide
alternate documentation per our
Fenestration U-factor
Documentation policy:
https://www.cityofaspen.com/Do
cumentCenter/View/6199/Fenest
ration-U-Factor-Policy-Revision-
PlanCheck (3)
File Name: WMR_ Revised Plan Submittal 3-28-20.pdf
Author: bonniem
Page Label: A3.05 NORTH AND WEST SIDE ELEVATIONS
Page Index: 16
Capture: No
Measurement: 1 Count
Depth:
Wall Area:
Unit: Count
Length:
Document Height: 9.8678 in
Document Width: 8.8591 in
Y: 2.2760 in
X: 5.8683 in
Creation Date: 7/17/2020 6:06:12 PM
Date: 7/17/2020 6:07:29 PM
Checkmark: Unchecked
Lock: Unlocked
Color:
Subject: PlanCheck
Status:
Width:
Height:
Area:
Volume:
Amend the North Elevation and
Roof Plan to show required
snow stops where roof sheds
onto driveway. (Ordinance 40,
2016)
Several of the Kolbe
windows listed exceed
the maximum .28
U-factor per 2015
IECC Table R402.1.2
as amended by
Ordinance 40, 2016.
Provide an
area-weighted
average per R402.3.1
or REScheck with UA
tradeoff per R402.1.5,
or revise windows as
needed.
Verify that all windows
and doors will have
NFRC labels on them
stating U-factor or
provide alternate
documentation per our
Fenestration U-factor
Documentation policy:
https://www.cityofaspe
n.com/DocumentCent
er/View/6199/Fenestra
tion-U-Factor-Policy-R
evision-
T.O. SLAB @ GARAGEEL.= 98'-6" VERIFY
T.O. SLAB @ LOWER EL.= 95'-6"
STANDING SEAM METAL ROOFING OVER
VERSASHIELD ROOF DECK PROTECTION OVER
GRACE ICE AND WATER SHIELD ON 5/8" PLYWD.
OVER FRAMING PER STRUCTURAL W/ R-49
CLOSED CELL SPRAY FOAM INSULATION AND
5/8" TYPE"X" GYP.BD.
GARAGE DOOR
ALUMINUM AND GLASS DOOR
VERTICAL SIDING INFILL AT TRUSS
41
16
17
1819 10
'
-
0
"
1
A4.1
1
A4.1
WALL CONSTRUCTION
DRY STACK THIN STONE ON TYVEK
ON EXISTING PLYWD. OVER 2 X 6'SW/ R-28 INSULATION AND 5/8"
TYPE "X" GYP. BD.
Amend the North
Elevation and Roof
Plan to show required
snow stops where roof
sheds onto driveway.
(Ordinance 40, 2016)
07/24/2020
File Name: WMR_ Revised Plan Submittal 3-28-20.pdf
Author: bonniem
Page Label: A3.05 NORTH AND WEST SIDE ELEVATIONS
Page Index: 16
Capture: No
Measurement: 1 Count
Depth:
Wall Area:
Unit: Count
Length:
Document Height: 7.2355 in
Document Width: 4.4308 in
Y: 8.3236 in
X: 3.7217 in
Creation Date: 7/17/2020 6:07:59 PM
Date: 7/20/2020 3:23:45 PM
Checkmark: Unchecked
Lock: Unlocked
Color:
Subject: PlanCheck
Status:
Width:
Height:
Area:
Volume:
Clarify whether the stone veneer
is less than 4". If less than 4"
provide a spec sheet with
installation instructions. If
greater than 4", provide an
exterior wall details showing the
supports and weeps required per
R703.8
File Name: WMR_ Revised Plan Submittal 3-28-20.pdf
Author: bonniem
Page Label: A5.01 WINDOW AND DOOR SCHEDULES
Page Index: 19
Capture: No
Measurement: 1 Count
Depth:
Wall Area:
Unit: Count
Length:
Document Height: 1.1597 in
Document Width: 1.5982 in
Y: 0.6095 in
X: 4.7796 in
Creation Date: 7/20/2020 4:06:25 PM
Date: 7/20/2020 4:06:25 PM
Checkmark: Unchecked
Lock: Unlocked
Color:
Subject: R308.4 Safety Glazing windows
Status:
Width:
Height:
Area:
Volume:
On the plans or window
schedule, label each individual
window that must be safety
glazed (R308.4).
R308.4 Safety Glazing windows (1)
T.O. SLAB @ GARAGE
EL.= 98'-6" VERIFY
T.O. SLAB @ LOWER
EL.= 95'-6"
GARAGE DOOR
ALUMINUM AND GLASS DOOR
1
A4.1
WALL CONSTRUCTION
DRY STACK THIN STONE ON TYVEK
ON EXISTING PLYWD. OVER 2 X 6'S
W/ R-28 INSULATION AND 5/8"
TYPE "X" GYP. BD.
Clarify whether the
stone veneer is less
than 4". If less than 4"
provide a spec sheet
with installation
instructions. If greater
than 4", provide an
exterior wall details
showing the supports
and weeps required
per R703.8
On the plans or
window schedule,
label each individual
window that must be
safety glazed
(R308.4).
07/24/2020
File Name: WMR_ Revised Plan Submittal 3-28-20.pdf
Author: bonniem
Page Label: JL OCDU (N U S)ZIIU2ftt<o
Page Index: 23
Capture: No
Measurement: 1 Count
Depth:
Wall Area:
Unit: Count
Length:
Document Height: 1.3514 in
Document Width: 3.9254 in
Y: 22.1819 in
X: 2.5280 in
Creation Date: 7/20/2020 4:08:15 PM
Date: 7/20/2020 4:11:08 PM
Checkmark: Unchecked
Lock: Unlocked
Color:
Subject: Special Inspection Program
Status:
Width:
Height:
Area:
Volume:
Additional information is required
on the special inspection section
on S3.1. Specify which items
require periodic vs continuous
inspection in accordance with
2015 IBC 1705. Provide a
special inspection agreement
signed by all required parties.
https://www.cityofaspen.com/Do
cumentCenter/View/5044/Specia
l-Inspection-Agreement-v2?bidId
=
Special Inspection Program (1)
Additional information is required on the special
inspection section on S3.1. Specify which items
require periodic vs continuous inspection in
accordance with 2015 IBC 1705. Provide a special
inspection agreement signed by all required parties.
https://www.cityofaspen.com/DocumentCenter/View/
5044/Special-Inspection-Agreement-v2?bidId=
07/24/2020
1
jeffrey@hancoxgroup.com
From:jeffrey@hancoxgroup.com
Sent:Thursday, July 23, 2020 2:09 PM
To:Bonnie Muhigirwa
Cc:dennis.murrray@cityofaspen.com; lauren.litchet@cityofaspen.com
Subject:RE: Building Comments - 0033-2020-BRES - 1265 MTN VIEW DR
Attachments:0033-2020-BRES_BuildingComments_1.pdf
Hi Bonnie:
In response to your email seeking updates and revisions here is the following information:
1.) Window and doors. I have uploaded the cutsheets from the Kolbe supplier that we will be using. I went ahead
and highlighted all of the U‐values in red for easy identification.
2.) Required snow stops. I have updated sheet A2.07 Roof Plan and sheet A3.05 North and West Side Elevations to
show the required snow and ice stops. Revised Set uploaded
3.) Exterior Stone detailing: I have updated sheet A3.05 North and West Side to state that the stone is 2” thick. I
have uploaded the Eldorado Stone Companies installation guidelines. Revised set uploaded
4.) Special Inspection: I am on this and getting the required signatures. I will upload when complete and email
everyone when it is done. Pending
Thanks!
Jeffrey R. Hancox
Architect, NCARB
Willits
314 Sopris Circle
Basalt, CO 81621
970‐306‐6300 Office
970‐618‐5588 Mobile
‐‐‐‐‐Original Message‐‐‐‐‐
From: Bonnie Muhigirwa <bonnie.muhigirwa@services.cityofaspen.com>
Sent: Monday, July 20, 2020 6:40 PM
To: jeffrey@hancoxgroup.com
Cc: dennis.murrray@cityofaspen.com; lauren.litchet@cityofaspen.com
Subject: Building Comments ‐ 0033‐2020‐BRES ‐ 1265 MTN VIEW DR
Hello JEFFREY ROBERT HANCOX,
I’ve reviewed your permit application; please see the attached comment list. Please contact me directly if you have any
questions on the comments. You may resubmit your responses online when you have received comments or approval
from all applicable review agencies. Please be sure to reach out to your permit coordinator to ensure you've received all
applicable comments prior to uploading responses. Once you have uploaded you comments online, please email your
permit coordinator directly to notify them as they will not receive an automated email from our system.
Address: 1265 MTN VIEW DR
Permit Number: 0033‐2020‐BRES
07/24/2020
2
Permit Coordinator: Lauren Litchet
These design documents have been reviewed for conformance to the International Codes as adopted and amended by
the City of Aspen. State and Federal regulations are administered where applicable. You can find a copy of all adopted
codes, ordinances, and policies on our website.
The attached corrections are required to be addressed. Revise and redraw the plans to clearly respond to the attached
comments and resubmit this comment letter with your written response to each comment on this list. Indicate which
detail or specification page shows the required information. Responses such as “will comply with code” are not
adequate. Revised drawings must clearly show code compliance.
Building plan check is only one part of the often complex process by which projects are reviewed for approval. These
parts are interrelated and are sometimes conflicting. It is ultimately the applicant’s responsibility to coordinate these
requirements.
Bonnie Muhigirwa
Plans Examiner
Community Development
130 S Galena St.
Aspen, CO 81611
p 970.429.2787
c 970.309.5119
Notice and Disclaimer:
This message is intended only for the individual or entity to which it is addressed and may contain information that is
confidential and exempt from disclosure pursuant to applicable law. If you are not the intended recipient, please reply
to the sender that you have received the message in error and then delete it. Further, the information or opinions
contained in this email are advisory in nature only and are not binding on the City of Aspen. If applicable, the
information and opinions contained in the email are based on current zoning and/or applicable building code regulations
which are subject to change in the future, and upon factual representations that may or may not be accurate. The
opinions and information contained herein do not create a legal or vested right or any claim of detrimental reliance.
07/24/2020