Heirloom
Direct Vent Gas Fireplace
75" [1905]
49-7/8" [1267]
40-1/16"[1018]
53-7/8" [1368]
66-5/8"[1692]
50-3/8"[1280]
73-5/16" [1862]
16"[406]
36-11/16"[932]
3-7/8"[98]
2-3/4"[70]
16-1/8"[410]
10-7/8"[276]
GasAccess ElectricalAccess
24"[610]
23-1/2"[597]Heat-ZonePort
®
63-15/16"[1624]
Heat-ZonePort
®
Heirloom HEIR50
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
HEIR50 Actual Framing Actual Framing Actual Framing Actual Framing 49-7/8 x 40-1/167573-9/16 73-5/16 73-9/16 66-5/8 65 24 24
TOP
FRONT
UNIT
FRONTS
FIRESCREEN ARCHED FIRESCREEN
LEFT RIGHT
1-1/4"
[32]
3-9/16"
[91]
54-11/16"
[1390]
45-11/16"
[1161]
44-7/16"
[1128]
54-11/16"
[1390]
44-7/16"
[1129]
40-5/8"
[1032]
45-11/16"
[1161]
3-9/16"
[91]
1-1/4"
[32]
07/14/2020
Specifications
GS/HTL/HEIR50_0217
Lakeville, MN
Phone: (800) 927-6841
Web: www.heatilator.com
APPLIANCE LOCATION
WALL PENETRATION
MANTEL LEG/WALL PROJECTIONS
119-1/8"[3026]
31-1/2"[800]
31-1/2"[800]
36-13/16"[935]
36-13/16"[935]
73-9/16"[1868]73-9/16"[1868]
73-9/16" [1868]
23-1/2"[597]
23-1/2"[597]
84-1/4" [2140]
84-1/4"[2140]
FRAMING DIMENSIONS
CLEARANCES TO COMBUSTIBLES
24"
[610]
65"
[1651]
73-9/16" [1868]
10"
[254]
1
56
3
6
12
9
59
62
65
68
FIREPLACE OPENING
1/2" Non-combustible
material
HEIR50
Measurement from fireplace
opening to bottom of appliance:
= 44-3/16" HEIR50
Notes: Measurements in inches.
Measurement is taken from
bottom of appliance.
MANTEL PROJECTIONS
*83-3/16"[2113]
82-3/16"[2088]
10"12"
Do not pack with insulationor other material.
* Shows center of vent framing hole with minimum vertical for top venting. Center of hole is 1" [25] above center of horizontal vent pipe.* Add height for chase deeper than 24".
7" Min
FireplaceOpening
Combustible ornon-combustible wall
Combustible ornon-combustible wall
14" Min
14" Min
CombustibleColumn
Non-combustibleColumn
4" Maximum
Factory-suppliednon-combustibleboard
FireplaceOpening
Factory-suppliednon-combustibleboard
6" Maximum
See section 13.Efor requiredclearances
1/2" Building Material
1/2" Building Material
Combustible Mantel
Non-combustible Mantel
0"
1"[25]1"[25]
See install manualsection 3.D 36"[914]
52"[1321]
from appliance
opening to
ceiling
96-3/16" [2443]
from bottom of
fireplace to ceilingNote: A 12" non-combustible
hearth extension is required.
The replace may be raised
from the oor a minimum of
3" to eliminate this
requirement. See installation
manual for more details.
Heirloom HEIR50
Combustible Mantel
Projections shown.
See install manual
for Non-combustible
Mantel Allowance.
Additional information can
be found online at www.
heatilator.com
Product information provided
is not complete and is subject
to change without notice.
Product installation must
adhere strictly to instructions
accompanying product to
avoid risk of fire and potential
injury.
NON-COMBUSTIBLE ZONE
13Heat & Glo • TRUE-36, TRUE-42, TRUE-50 Installation Manual • 2282-980 Rev. L • 1/16
Non-Combustible Zone
Figure 3.7 Non-Combustible Zone
NO COMBUSTIBLES IN HATCHED AREA
1/2 IN. BUILDING MATERIAL
(MAY BE COMBUSTIBLE)
FACTORY-SUPPLIED
1/2 IN.
NON-COMBUSTIBLE
BOARD
PIPE IS FOR VISUAL
REFERENCE ONLY
1 IN.
= COMBUSTIBLES
NOT ALLOWED
39 IN.
2 X 4 OR GREATER
FRAMING MATERIAL
NOTE:
2 X 4 HEADER
CONFIGURATION
2 X 4 ONLY IN
GRAY AREA
PRODUCT LISTING CODES
US ANSI Z21.88-2014
CAN CSA 2.33-2014
UL307B