File Documents.334 McSkimming Rd.0073-2020-BRES (20)
Job Name: System Reference:Date: INDOOR UNIT FEATURES •Unobtrusive ceiling-concealed design for short-run ductwork. •Wide ranging external static pressure (0.14-0.60 in. WG) • Built-in condensate lift mechanism (up to 27-9/16") • Auto fan speed mode • Optional FB Series filter boxes for easy access and service • Ideal for residential homes, retail shopping centers, larger classrooms, office complexes, conference rooms, ballrooms, fitness centers, and more SUBMITTAL DATA: PEAD-A15AA7 15,000 BTU/H HORIZONTAL-DUCTED FOR MXZ MULTI-ZONE SYSTEMS Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. P-SERIES 07/14/2020 Cooling Capacity1, 3 Btu/h 15,000 Heating Capacity1, 3 Btu/h 18,000 Electrical Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 198 – 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 MCA A 1.69 Fan Motor Full Load Amperage A 1.35 Fan Motor Output W 85 Airflow Rate, Dry CFM 424-512-600 External Static Pressure in. WG 0.14-0.20-0.28-0.40-0.60 Sound Pressure Level dB(A)29-32-36 Drain Pipe Size In. (mm)1-1/4 (32) Condensate Lift Mechanism, Max. Distance In. (mm)27-9/16 (700) Heat Exchanger Type Plate fin coil External Finish Color Galvanized Unit Dimensions W: In. (mm)35-7/16 (900) D: In. (mm)28-7/8 (732) H: In. (mm)9-7/8 (250) Package Dimensions W: In.45-5/16 D: In.34-11/16 H: In.13-7/16 Unit Weight Lbs. (kg)62 (28) Package Weight Lbs.69 Refrigerant Type R410A Piping Gas Pipe Size O.D. (Flared)In. (mm)1/2 (12.7) Liquid Pipe Size O.D. (Flared)In. (mm)1/4 (6.35) Notes: Nominal Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)70 DB, 60 WB // 47 DB, 43 WB 3Capacity varies based on the number of indoor units operating and the model of the MXZ unit. For reference to connected capacity charts, please refer MXZ Multi-Zone Outdoor Unit Operational Performance. SPECIFICATIONS: PEAD-A15AA7 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 07/14/2020 Filter Box with MERV 13 Filters □ FBM2-2 Wireless Signal Receiver □ PAR-SA9CA-E Wireless Signal Receiver □ PAR-FA32MA-W Wireless Signal Receiver □ PAR-FA32MA-E Wireless Remote Controller □ PAR-FL32MA-E Backlit, Wall-mounted, Wireless Controller □ MHK1 Portable Central Controller □ MCCH1 Wired MA Controller □ PAR-33MAA Simple MA Controller □ PAC-YT53CRAU Touch MA Controller □ PAR-CT01MAU-SB Airzone ZBS Wired Blueface Principal Controller White □ AZZBSBLUEFACECB Airzone ZBS Wired Think Controller White □ AZZBSTHINKCB Airzone ZBS Wireless Think Controller White □ AZZBSTHINKRB Airzone ZBS Wired Lite Controller White □ AZZBSLITECB Airzone ZBS Wireless Lite Controller White □ AZZBSLITERB Wired Remote Sensor □ PAC-SE41TS-E Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 □ MOS1 Flush Mount Remote Temperature Sensor □ PAC-USSEN001-FM-1 System Control Interface □ MAC-333IF-E Wireless Interface □ PAC-USWHS002-WF-1 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter □ CN24RELAY-KIT-CM3 Connector cable for remote display □ PAC-SA88HA-EP Connector for CN32 (remote on/off)□ PAC-SE55RA-E Lockdown Bracket for Hand-held Remote Controllers □ RCMKP1CB Remote Operation Adapter1 □ PAC-SF40RM-E Blue Diamond Sensor Extension Cable —15 Ft.□ C13-103 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]□ X87-721 - 208/230V Drain Pan Level Sensor □ DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Unable to use with wireless remote controller ACCESSORIES: PEAD-A15AA7 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 07/14/2020 20 0 ( 7 - 7 / 8 ) 120° 12 0 ° ø125 13 5 378(14-15/16)153(6-1/16) B( S u s p e n s i o n b o l t p i t c h ) 23 ( 1 5 / 1 6 ) CA 40 ( 1 - 5 / 8 ) 15(5/8) 40 ( 1 - 5 / 8 ) H± 3 ( H ± 1 / 8 ) J± 3 ( J ± 1 / 8 ) 58 ( 2 - 5 / 1 6 ) 20 ( 1 3 / 1 6 ) D ( D u c t ) 30 ( 1 - 3 / 1 6 ) 10 0 ( 3 - 1 5 / 1 6 ) X ( E - 1 ) = F 10 0 ( 3 - 1 5 / 1 6 ) 10(7/16) 57(2-1/4)643(25-3/8) 18(3/4) 210(8-5/16) 21 ( 7 / 8 ) G 732(28-7/8) 32(1-5/16)700(27-9/16) 238(9-3/8) 10(7/16) 33 ( 1 - 5 / 1 6 ) 40 ( 1 - 5 / 8 ) 10 0 ( 3 - 1 5 / 1 6 ) 12 2 ( 4 - 1 3 / 1 6 ) 17 8 ( 7 - 1 / 1 6 ) 136 67 356(14-1/16) 21 7 ( 8 - 9 / 1 6 ) 41 ( 1 - 5 / 8 ) 25 0 ( 9 - 7 / 8 ) 23 ( 1 5 / 1 6 ) (4-15/16 ) (5 - 3 / 8 ) 3-ø2.9(1/8) mount hole Drain pipe(O.D ø32(1-1/4)Fresh air intake ø100(3-15/16) knock out hole 2XE-ø2.9(1/8) (Suspension bolt pitch) Air filter Drain pipe (Integral lift pump outlet) Drain pump (D U C T ) 2X2-ø2.9(1/8) 1Refrigerant piping (gas)(5-3/8)(2-11/16) (Emergency drain) 2Refrigerant piping(liquid) Drain pipe(O.Dø32(1-1/4))(Gravity drain) Terminal block(Power source) Terminal block(Transmission) Note 4 Control box (O.Dø32(1-1/4)) Top Top Bottom view Top Bottom Inlet air side view Outlet air side view Opposite piping side view Piping side view (43-5/16) (55-1/8) (45-7/16) (57-1/4) (59-1/16) (53-9/16) (47-1/4) (41-3/4) (39-3/8) (51-3/16) (41-11/16) (53-1/2) 2Liquid pipe1Gas pipe 1058 13581300 Model 1200 1110601100 1154 1400 ø15.88 (5/8) 1454 1500 ø9.52 (3/8) 1360 14 1000PEAD-A24,30AA7 PEAD-A36,42AA7 Unit:mm(in.) Air inlet Air outlet Note 1.Use an M10 screw for the suspension bolt (field supply). 2.Keep the service space for maintenance at the bottom. 3.This drawing is for PEAD-A24·30·36·42 AA7 models,which have 2 fans. PEAD-A09· 12·15·18AA7 models have 1 fan. 4.If the inlet duct is used,remove the air filter (supplied with the unit), then install the filter (field supply) at the suction side. 5.Heat air to 0°C (32°F) or higher when taking fresh air with a fresh air intake. PEAD-A24,30AA7 PEAD-A36,42AA7 PEAD-A12,15, 18AA7 Model A EDCB F G Unit:mm(in.) (35-7/16) (37-9/16) (39-3/8) (33-7/8) (31-1/2) (33-13/16) 8581000 9860900 954 800PEAD-A09,12, 15,18AA7 ø12.7 (1/2) ø6.35 (1/4) (3-1/8) 78 H (2-7/8) 72 J 66 (2-5/8) 62 (2-1/2) PEAD-A09AA7 ø9.52 (3/8) ø6.35 (1/4) 62 (2-1/2) FORM# PEAD-A15AA7 FOR MXZ MULTI-ZONE SYSTEMS - 201902Ver2 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: PEAD-A15AA7 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 07/14/2020