HomeMy WebLinkAboutFile Documents.134 E Bleeker St.0064-2022-BCHO (13)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK SEE NOTES #1 PLANS It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. bobn 10/12/2022ZONING REVIEWED BY ZONING 10/12/2022 bobn It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen. The review and approval by the City is offered only to assist the applicant's understanding of the applicable Land Use Code requirements. The issuance of a permit based on construction documents and other data shall not prevent the City of Aspen from requiring the correction of errors in the construction documents and other data. ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 Reviewed by Engineering 10/19/2023 3:52:44 PM "It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen. The review and approval by the City is offered only to assist the applicant's understanding of the applicable Engineering requirements." The issuance of a permit based on construction documents and other data shall not prevent the City of Aspen from requiring the correction of errors in the construction documents and other data. City Development Engineer's Comments 1. Encroachments: Any existing or planned encroachments into the public right-of-way, including temporary construction trailers and dumpsters, must be applied for licensing at City Engineering (920- 5080). Five davs advance notice is required to obtain a temporary encroachment license. 2. Right-of-way Permits: Approval of these plans by the City Building Dept. is for work on private property only. Design approvals for proposed work (including landscaping) in the public right-of-way (ROW) must be obtained from City Engineering Dept. (920-5080) and Parks Dept. (920-5120) . A permit for work in the public right-of-way must be obtained from the City Engineering Dept. five days in advance of when the permit is needed. 3. Mud, dirt and debris may not be tracked onto the adjacent public ROW, and the adjacent ROW must be clean at the end of eachworkday. Construct mud rack if needed. Trucks hauling demolished materialsmust becovered. 4. Utilities in ROW: No utility pedestals, meters, or electric transformers can be installed in the public right-of-way. Provide utility easements on private property as needed. 5. Certificate of Occupancy (CO) Inspection: Engineering CO Inspection includes but is not limited to: (a) witnessing that all property corners havemonuments, (b) drainage improvements were installed as approved, (c) easements are documented, (d) no unapproved ROW encroachments exist, and (e) the ROW has been restored. Call 429-2750 to arrange CO inspection. 6. Snowmelt Driveways : (i) Snowmelt runoff from driveway cannot flow into street . A grate or swale must intercept runoff before street. (ii) Snowmelt installation in the public ROW requires an encroach- ment permit. 7. Drainage Issues: (i) Foundation drains cannot go to a dry well receiving other drainage flows. (ii) City must be notified of drainage plan changes. (iii) Plan approval assumes no ground water. If ground water is encountered, call the Senior Dev. Engineer at 920-5080. Call for an open hole inspection prior to placement of the drywell. 8. No Loose Material Storage allowed in R.O.W. 9. Neighbor Notification: For all excavation, the Contractor must comply with neighbor notification requirements per Section 3307 of the 2003 International Building Code (IBC) REFERENCES FROM 2015 IRC CV/A = crawl space ventilation required, sec. R408.1 Access required, R408.4 EE = emergency escape required sec R310.1 EU = enclosed usable space under stairs shall be ½” Gyp, sec R302.7 G/D = garage/dwelling separation, sec R302.5 and R302.6 STC = Sound transmission class not less than 45 at dwelling separations, app K RV = roof and rafter ventilation required, R806.1 A = attic access 22” x 30”, 30” headroom above, R807.1 SA = smoke alarms installed to NFPA 72 requirements, sec R314 CO = carbon monoxide detector per City Ordinance 41 series 2008 SG = safety glazing required, sec R308.4 GR = guardrails, 36” min ht, 4” max opening; req at 30” drop any point w/in 36” horizontally, sec R312 WFP = window fall protection- operable window <24” AFF & >72” above grade: use opening control device listed to ASTM F2090, sec R312.2 HR = handrails 34”-38” ht, sec R311.7.8 SI = stairway illumination, sec R303.7 PD = protect against decay, sec R317 REFERENCES FROM 2015 IMC V = bathroom and balanced whole house mechanical ventilation req. Ordinance 40, 2016 DE = clothes dryer exhaust, sec 504. Makeup air req’d if over 200 CFM AS = access and service space for maintenance req’d, sec 306 MA = make up air required if hood exhausts greater than 400 CFM, sec 505.2 ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes, 501.3.1 IT= intake openings 10’ from lot line & contaminant sources (vents, streets), 401.4 D = fasten and seal all ductwork per 603.9 REFERENCES FROM 2015 IFGC DV = direct vent req’d, sec 303.3 CA = combustion air not taken from bedrooms, bathrooms or storage sec 303.3 OD = outdoor appliances must be listed for outdoor use, sec 303.6 REFERENCES FROM 2015 IECC F = new or replacement glazing shall not exceed 0.28 U-Value, NFRC label required, Ordinance 40, 2016 L = 75% of lamps in permanently installed lights must be high efficacy, sec R404.1 SE = Continuous air barrier required; all exterior joints, cracks, and holes to be caulked, gasketed, sealed, table R402.4.1.1 REFERENCES FROM 2014 NEC EP = electric panel 'happy space' 30"x36"x78", not in storage, sec 110.26 SPECIAL INSPECTION REQUIRED: -Structural steel welding: Field & Shop -High strength bolting -Epoxy anchors -Intumescent paint -Spray applied fire resistive materials -Permanent micropiles Special inspection is required per 2015 IBC section 1704. Inspector to verify that copy of agreement for inspection program to be on the job site prior to performing any inspections. A copy of all Special Inspector field reports to be on the job site for inspectors' review if requested. Failure to comply may result in denial of inspection. GAS LOG 2015 IFGC Section 602: Install per manufacturer’s instructions Sec 634: Permanently open damper Sec 501.15: Flue passageway, 1 sq in per 2000 btu/hr input Sec 409.1: Shutoff valve req’d 2015 IRC Section R1001.5, R1004: Firebox walls of masonry construction or factory built. Sec R1001.9, R1001.10: Hearth and Extension supported by non-combustible construction. Minimum dimensions: <6 sqft opening: 16” deep, 8” each side. >=6 sqft opening: 20” deep, 12” each side. Sec R1006: Exterior air supply req’d. Intake no higher than firebox 2015 IECC Section R402.4.2: Flue sentinel or tight fitting door req’d External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ 0064-2022-BCHO 443.41 total= 175 #1 + 268.41 Changer order 1/11/24 X 98% no Jim Pomeroy L0-01 01/12/2024 jimp SEE NOTES #1 PLANS 1 APPLICATION ACCEPTED DATE: 2022-08-25 PERMIT NUMBER: 0064-2022-BCHO COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 134 E BLEEKER ST UNIT: PARCEL ID: 273707315002 LEGAL DESCRIPTION: CITY AND TOWNSITE OF ASPEN OWNER: 134 E BLEEKER LLC PERMIT CONTRACTOR: STEEPLECHASE CONSTRUCTION DESCRIPTION OF WORK No change to building footprint; no change to gross SF; no change to allowable SF. All fenestration changes approved by HP Monitor as noted in elevations. See 10.Narrative Summary of Changes. USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? Yes CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 D BUILDING TYPE (IRC) One family REQUIRED SPECIAL INSPECTIONS High-Strength Bolting;Structural Steel Welding CONSTRUCTION TYPE ENERGY CODE COMPLIANCE Prescriptive Table OCCUPANCY GROUP (IBC) R-3 WORK CHANGES BUILDING FOOTPRINT? No CODE EDITIONS 2015 IRC TOTAL SPA SQ.FT. OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. 443 HISTORIC PROPERTY? Yes TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING?