File Documents.334 McSkimming Rd.0073-2020-BRES (32)
07/14/2020 07/14/2020 Extensive landscaping is not permitted within utility easements. The utility easement needs to remain usable. Please revise. Any boulder wall sections that fall into the setback need to be 30" or less from grade. 07/14/2020 07/14/2020 Be advised that pursuant to WELS Definition, all infrastructure for "temporary irrigation" (valves, lines, heads,etc) must be removed after a specified amount of time. A temporary water service agreement with the City Water Dept. is required for "temporary irrigation". That said, "establishment irrigation" by definition can be left in place for drought conditions. Consider utilizing "establishment irrigation" only rather than temporary irrigation, or contact the Water Department to enter into a water service agreement. Indicate irrigation valve numbers for each hydrozone as per WELS Section 5.2.8. Revise. Cornus sericea and Ajuga reptans are medium water species. Revise all plans and calculations accordingly. I HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPING STANDARDS AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE IRRIGATION DESIGN PLAN. EDWARD W PRICE, CID, CLIA DATE 1.APPLICANT IS RESPONSIBLE FOR ASSURING OPERATING PRESSURE AT EACH EMISSION DEVICE IS WITHIN THE MANUFACTURER'S RECOMMENDED PRESSURE RANGE FOR OPTIMAL PERFORMANCE. IF PRESSURE IS NOT WITHIN THE PREFERRED RANGE, ACTIONS DESCRIBED IN SECTION 5.1.11 OF THE WATER EFFICIENT LANDSCAPING STANDARDS MUST BE TAKEN. 2.SPRINKLERS WITHIN INDIVIDUAL IRRIGATION ZONE SHALL HAVE MATCHED PRECIPITATION RATES, UNLESS OTHERWISE DIRECTED BY THE MANUFACTURER'S RECOMMENDATIONS. 3.SLOPES GREATER THAN TWENTY-FIVE PERCENT (25%) SHALL NOT USE SPRINKLERS WITH AN APPLICATION RATE EXCEEDING 0.75 INCHES PER HOUR. REFER TO CITY OF ASPEN WATER EFFICIENT LANDSCAPING STANDARDS SECTION 5.2.4 FOR EXCEPTIONS, AND TO SECTION 5.5 FOR LANDSCAPE SCHEDULING TO PREVENT RUNOFF. 4.REMOVING VEGETATION OR AMENDING SOIL UNDER EXISTING TREES REQUIRES HAND GRUBBING NO DEEPER THAN FOUR INCHES (4") WITH ADDITIONAL SOIL ABOVE EXISTING GRADE LIMITED TO A MAXIMUM OF THREE INCHES (3"). IRRIGATION WORK PERFORMED WITHIN THE DRIP LINE OF EXISTING TREES REQUIRES HAND GRUBBING AS FAR FROM TREE TRUNKS AS PRACTICALLY POSSIBLE, NO DEEPER THAN SIX INCHES (6"). DO NOT CUT ROOTS LARGER THAN FOUR INCHES (4") IN DIAMETER. 5.AN IRRIGATION MAINTENANCE SCHEDULE AND IRRIGATION MANAGEMENT PLAN IS REQUIRED AS DESCRIBED IN SECTIONS 5.4 THROUGH 5.8 OF THE ASPEN WATER EFFICIENT LANDSCAPING STANDARDS. ENSURE THE FOLLOWING: 1.TURF GRASS SPRINKLER HEADS SHALL HAVE A DISTRIBUTION UNIFORMITY OF 0.65 OR HIGHER USING THE PROTOCOL DEFINED IN ASABE/ICC 802-2014. 2.POP-UPS IN TURF AREAS HAVE A MINIMUM HEIGHT OF 6". ID#: 50322 05/04/2020 CITY OF ASPEN GENERAL NOTES A1141" INDICATES LATERAL DISCHARGE (GPM) INDICATES VALVE SIZE (INCHES) INDICATES CONTROLLER AND STATION NUMBER INDICATES ZONE DESIGN PRESSURE (PSI) INDICATES PRECIP. RATE (INCHES PER HOUR)0.50 30 THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY OTHERS AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW PREVENTION UNIT AND MASTER VALVE ASSEMBLY AS INDICATED, IN THE LANDSCAPE AREA OUTSIDE THE GARAGE, SAME SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S REPRESENTATIVE. WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER'S REPRESENTATIVE. FINAL LOCATION TO BE APPROVED BY OWNER'S REPRESENTATIVE. THE IRRIGATION CONTRACTOR SHALL INSTALL A LOCKABLE ISOLATION GATE VALVE ASSEMBLY DOWNSTREAM OF THE BACKFLOW PREVENTION DEVICE AT THE APPROXIMATE LOCATION SHOWN, PER CITY OF ASPEN REQUIREMENTS. INSTALL ALL IRRIGATION EQUIPMENT IN THE LANDSCAPE AREA OUTSIDE THE GARAGE. CONSTRUCTION NOTES 1 2 3 REMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ-PRB-100-COM QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD 5RC ISOLATION GATE VALVE ASSEMBLY:MATCO 514 POINT-OF-CONNECTION ASSEMBLYPOINT-OF-CONNECTION ASSEMBLY BACKFLOW PREVENTION ASSEMBLY:FEBCO 825YA (3/4-INCH) UNCONNECTED PIPE CROSSING LATERAL PIPE TO SPRINKLERS: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC MAINLINE PIPE:CLASS 200 PVC 1-INCH SIZE UNLESS OTHERWISE INDICATED SLEEVES:CLASS 200 PVC MASTER VALVE ASSEMBLY:RAIN BIRD PESB POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): LM O HUNTER PROS-06-PRS40-CV W/MP1000 NOZZLES 40 PSI 8 FEET TO 15 FEET M-0.42 L-0.63 O-0.84 POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): RGK HUNTER PROS-06-PRS40-CV W/MP2000 NOZZLES 40 PSI K-0.77 G-1.10 R-1.48 13 FEET TO 21 FEET POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): YB A HUNTER PROS-06-PRS40-CV W/MP3000 NOZZLES 40 PSI B-1.82 Y-2.73 A-3.64 22 FEET TO 30 FEET POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): C HUNTER PROS-06-PRS40-CV W/MPCORNER NOZZLE 40 PSI 45°-0.19 90°-0.39 105°-0.45 8 FEET TO 14 FEET POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): LST RST SST HUNTER PROS-06-PRS40-CV W/MPSTRIP NOZZLES 40 PSI SST - 4'X24'-0.34 5'X30'-0.47 LCS/RCS - 4'X12'-0.17 5'X15'-0.23 ADJUSTABLE RECTANGULAR SPRAY IRRIGATION LEGEND POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): ADJ HUNTER PROS-06-PRS40-CV W/MP800SR NOZZLES 40 PSI 90°-0.23 180°-0.42 210°-0.43 360°-0.78 6 FEET TO 12 FEET INLINE DRIP TUBING:NETAFIM TLCV26-12 WITH RAINBIRD XQF DRIPLINE HEADER INLINE TREE DRIP RING ASSEMBLY:RAIN BIRD XFS-CV-09-12 REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS: RAIN BIRD PEB (SIZED PER PLAN) FLOW SENSOR ASSEMBLY:F FLOWMEC QS200-10 ULTRASONIC LATERAL PIPE TO TREE EMITTERS: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC LATERAL PIPE TO INLINE DRIP HEADER: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC LOCKABLE VALVE PER ASPEN WELS SECTION 5.1.3 1.THE SYSTEM DESIGN ASSUMES A MINIMUM PRESSURE FOR THE IRRIGATION SYSTEM OF 79 PSI , AT A MAXIMUM DISCHARGE OF 10 GPM AT THE 3/4-INCH IRRIGATION POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. 2.READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. 3.COORDINATE UTILITY LOCATES ("CALL BEFORE YOU DIG") OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 4.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES, OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. 5.THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED: A.ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY, INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHENEVER POSSIBLE. B.TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES. C.USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF TEES IN THE BULLNOSE CONFIGURATION, OR USE OF CROSS TYPE FITTINGS IS NOT ALLOWED. 6.PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT: A.TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVES. B.TWO (2) OF EACH SERVICING WRENCH OR TOOL NEEDED FOR COMPLETE ACCESS, ADJUSTMENT, AND REPAIR OF ALL ROTARY SPRINKLERS. 7.SELECT NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARCS WHICH PROVIDE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE BEST PERFORMANCE. 8.THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. PIPE SLEEVES SHALL BE SIZED TWICE THE NOMINAL SIZE OF THE PIPE PASSING THROUGH. 9.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 10.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 11.INSTALL TWO (2) #14 AWG CONTROL WIRES, FOR USE AS SPARES. INSTALL SPARE WIRES FROM CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE. COIL 3 FEET OF WIRE IN VALVE BOX. 12.THE IRRIGATION CONTRACTOR SHALL USE FLOW CONTROL ON ALL ZONE CONTROL VALVES TO ACHIEVE DESIGN PRESSURE AT MOST REMOTE OR HIGHEST ELEVATION EMISSION DEVICE ON EACH ZONE. SEE LEGEND AND VALVE DESIGNATORS FOR EQUIPMENT DESIGN PRESSURE. 13.ALTHOUGH TREES AND SHRUBS WITH DIFFERENT WATER REQUIREMENTS ARE IRRIGATED ON THE SAME DRIP ZONE, THE CONTRACTOR SHALL REFER TO THE EMITTER SCHEDULE IN THE IRRIGATION DETAILS TO INSTALL THE CORRECT SIZE AND QUANTITY OF EMITTERS PER PLANT WATER REQUIREMENTS. REFER TO LANDSCAPE PLANS FOR SPECIFIC PLANT SPECIES AND WATER REQUIREMENTS. 14.SENSORS (E.G., RAIN, FREEZE, WIND, AND/OR SOIL MOISTURE ETC.), EITHER INTEGRAL OR AUXILIARY, THAT SUSPEND OR ALTER IRRIGATION OPERATION DURING UNFAVORABLE WEATHER CONDITIONS OR WHEN SUFFICIENT SOIL MOISTURE IS PRESENT SHALL BE REQUIRED ON ALL IRRIGATION SYSTEMS. INSTALLATION GENERAL NOTES IRRIGATION CONTROLLER UNIT WITHC WR2 WIRELESS RAIN/FREEZE SENSOR AND IQ NCC CARTRIDGE CONTROLLER A: RAIN BIRD ESP-LXMEF; 16 STATIONS USED 4 IRRIGATION NOTES AND LEGEND I-1.0 issue: sheet #: sheet title: project no: COPYRIGHT © NAVdesign drawn by:hines 01/22/20 SD COORD 02/19/20 ALT GRADING 02/25/20 REV T SURVEY 03/23/20 TREE R PERMIT 03/31/20 RE COMMENTS 04/10/20 WELS COORD 04/22/20 CLIENT REVIEW 05/01/20 IRRIGATION PERMIT p:: 970.710.2717 Snowmass Village, CO. 81615 P.O. BOX 5153 e:: info@navdesign.net www.navdesign.net design COLLABORATE+DESIGN+CREATE date:revision: HA M P L E M A N R E S I D E N C E 20101 These drawings as instruments of service, remain the property of NAVdesign. Any changes, publications or unauthorized use is prohibited unless approved by NAVdesign. LO T 1 1 , B L O C K 2 - A S P E N G R O V E S U B D I V I S I O N 33 4 M c S K I M M I N G R O A D As p e n , C o l o r a d o 8 1 6 1 1 FOR PLANNING & APPROVALS PURPOSES ONLY, NOT FOR CONSTRUCTION approval: 98 SF 07/14/2020 WELS Section 4.3.2 L&M requires that the City Forester review and approved any disturbance under existing trees. WELS cannot be approved until the Forester's review/approval. Revise Note accordingly. K K M K K K K K K M M B K K K M M M M ADJ C ADJ C C C B K K L G C ADJ K K MLST RST M M M L M SST SST SST L M M M L M M L M M M M M L M M M M M M M M M M M M G M K K M M M M K K K L M L M M SST SST ADJ ADJ ADJ ADJ ADJ M ADJ M M M B B ADJ K B CONTROLLER 120 VAC POWER REQUIRED 2 POC SIZE: 3/4-INCH PRESSURE: 79 PSI FLOW: 10 GPM 1 C F C1 4.17 0.49 1" C2 5.74 0.38 1"C3 5.61 0.48 1" C5 1.44 0.79 1" C6 6.65 0.37 1" C7 5.74 0.39 1" C9 7.64 0.42 1" C11 8.77 0.43 1"C13 5.27 0.42 1" C14 Drip Shrub 1" C8 Drip Tree 1" C10 Drip Tree 1" C12 Drip Tree 1" C4 Drip Tree 1" 40 40 40 40 30 30 40 304030 40 3 4 40 40 30 A1141" INDICATES LATERAL DISCHARGE (GPM) INDICATES VALVE SIZE (INCHES) INDICATES CONTROLLER AND STATION NUMBER INDICATES ZONE DESIGN PRESSURE (PSI) INDICATES PRECIP. RATE (INCHES PER HOUR)0.50 30 REMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ-PRB-100-COM QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD 5RC ISOLATION GATE VALVE ASSEMBLY:MATCO 514 POINT-OF-CONNECTION ASSEMBLYPOINT-OF-CONNECTION ASSEMBLY BACKFLOW PREVENTION ASSEMBLY:FEBCO 825YA (3/4-INCH) UNCONNECTED PIPE CROSSING LATERAL PIPE TO SPRINKLERS: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC MAINLINE PIPE:CLASS 200 PVC 1-INCH SIZE UNLESS OTHERWISE INDICATED SLEEVES:CLASS 200 PVC MASTER VALVE ASSEMBLY:RAIN BIRD PESB POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): LM O HUNTER PROS-06-PRS40-CV W/MP1000 NOZZLES 40 PSI 8 FEET TO 15 FEET M-0.42 L-0.63 O-0.84 POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): RGK HUNTER PROS-06-PRS40-CV W/MP2000 NOZZLES 40 PSI K-0.77 G-1.10 R-1.48 13 FEET TO 21 FEET POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): YB A HUNTER PROS-06-PRS40-CV W/MP3000 NOZZLES 40 PSI B-1.82 Y-2.73 A-3.64 22 FEET TO 30 FEET POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): C HUNTER PROS-06-PRS40-CV W/MPCORNER NOZZLE 40 PSI 45°-0.19 90°-0.39 105°-0.45 8 FEET TO 14 FEET POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): LST RST SST HUNTER PROS-06-PRS40-CV W/MPSTRIP NOZZLES 40 PSI SST - 4'X24'-0.34 5'X30'-0.47 LCS/RCS - 4'X12'-0.17 5'X15'-0.23 ADJUSTABLE RECTANGULAR SPRAY IRRIGATION LEGEND POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): ADJ HUNTER PROS-06-PRS40-CV W/MP800SR NOZZLES 40 PSI 90°-0.23 180°-0.42 210°-0.43 360°-0.78 6 FEET TO 12 FEET INLINE DRIP TUBING:NETAFIM TLCV26-12 WITH RAINBIRD XQF DRIPLINE HEADER INLINE TREE DRIP RING ASSEMBLY:RAIN BIRD XFS-CV-09-12 REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS: RAIN BIRD PEB (SIZED PER PLAN) FLOW SENSOR ASSEMBLY:F FLOWMEC QS200-10 ULTRASONIC LATERAL PIPE TO TREE EMITTERS: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC LATERAL PIPE TO INLINE DRIP HEADER: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC LOCKABLE VALVE PER ASPEN WELS SECTION 5.1.3 IRRIGATION CONTROLLER UNIT WITHC WR2 WIRELESS RAIN/FREEZE SENSOR AND IQ NCC CARTRIDGE CONTROLLER A: RAIN BIRD ESP-LXMEF; 16 STATIONS USED THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY OTHERS AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW PREVENTION UNIT AND MASTER VALVE ASSEMBLY AS INDICATED, IN THE LANDSCAPE AREA OUTSIDE THE GARAGE, SAME SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S REPRESENTATIVE. WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER'S REPRESENTATIVE. FINAL LOCATION TO BE APPROVED BY OWNER'S REPRESENTATIVE. THE IRRIGATION CONTRACTOR SHALL INSTALL A LOCKABLE ISOLATION GATE VALVE ASSEMBLY DOWNSTREAM OF THE BACKFLOW PREVENTION DEVICE AT THE APPROXIMATE LOCATION SHOWN, PER CITY OF ASPEN REQUIREMENTS. INSTALL ALL IRRIGATION EQUIPMENT IN THE LANDSCAPE AREA OUTSIDE THE GARAGE. CONSTRUCTION NOTES 1 2 3 4 PROPOSED IRRIGATION I-1.1 issue: sheet #: sheet title: project no: COPYRIGHT © NAVdesign drawn by:hines 01/22/20 SD COORD 02/19/20 ALT GRADING 02/25/20 REV T SURVEY 03/23/20 TREE R PERMIT 03/31/20 RE COMMENTS 04/10/20 WELS COORD 04/22/20 CLIENT REVIEW 05/01/20 IRRIGATION PERMIT p:: 970.710.2717 Snowmass Village, CO. 81615 P.O. BOX 5153 e:: info@navdesign.net www.navdesign.net design COLLABORATE+DESIGN+CREATE date:revision: HA M P L E M A N R E S I D E N C E 20101 These drawings as instruments of service, remain the property of NAVdesign. Any changes, publications or unauthorized use is prohibited unless approved by NAVdesign. LO T 1 1 , B L O C K 2 - A S P E N G R O V E S U B D I V I S I O N 33 4 M c S K I M M I N G R O A D As p e n , C o l o r a d o 8 1 6 1 1 FOR PLANNING & APPROVALS PURPOSES ONLY, NOT FOR CONSTRUCTION approval: 98 SF NO R T H 07/14/2020 IRRIGATION DETAILS I-1.2 issue: sheet #: sheet title: project no: COPYRIGHT © NAVdesign drawn by:hines 01/22/20 SD COORD 02/19/20 ALT GRADING 02/25/20 REV T SURVEY 03/23/20 TREE R PERMIT 03/31/20 RE COMMENTS 04/10/20 WELS COORD 04/22/20 CLIENT REVIEW 05/01/20 IRRIGATION PERMIT p:: 970.710.2717 Snowmass Village, CO. 81615 P.O. BOX 5153 e:: info@navdesign.net www.navdesign.net design COLLABORATE+DESIGN+CREATE date:revision: HA M P L E M A N R E S I D E N C E 20101 These drawings as instruments of service, remain the property of NAVdesign. Any changes, publications or unauthorized use is prohibited unless approved by NAVdesign. LO T 1 1 , B L O C K 2 - A S P E N G R O V E S U B D I V I S I O N 33 4 M c S K I M M I N G R O A D As p e n , C o l o r a d o 8 1 6 1 1 FOR PLANNING & APPROVALS PURPOSES ONLY, NOT FOR CONSTRUCTION approval: 98 SF 32 4 5 6 7 8 FLOW SENSOR ASSEMBLY ISOLATION GATE VALVE ASSEMBLY QUICK COUPLING VALVE ASSEMBLY REMOTE CONTROL TURF VALVE ASSEMBLY REMOTE CONTROL DRIP VALVE ASSEMBLY 6-INCH POP UP MP-ROTATOR ASSEMBLY MASTER VALVE ASSEMBLY 9 INLINE DRIP RING SPIRAL ASSEMBLY FOR TREEs 1 BACKFLOW PREVENTION UNIT ASSEMBLY 07/14/2020 I-1.3 issue: sheet #: sheet title: project no: COPYRIGHT © NAVdesign drawn by:hines 01/22/20 SD COORD 02/19/20 ALT GRADING 02/25/20 REV T SURVEY 03/23/20 TREE R PERMIT 03/31/20 RE COMMENTS 04/10/20 WELS COORD 04/22/20 CLIENT REVIEW 05/01/20 IRRIGATION PERMIT p:: 970.710.2717 Snowmass Village, CO. 81615 P.O. BOX 5153 e:: info@navdesign.net www.navdesign.net design COLLABORATE+DESIGN+CREATE date:revision: HA M P L E M A N R E S I D E N C E 20101 These drawings as instruments of service, remain the property of NAVdesign. Any changes, publications or unauthorized use is prohibited unless approved by NAVdesign. LO T 1 1 , B L O C K 2 - A S P E N G R O V E S U B D I V I S I O N 33 4 M c S K I M M I N G R O A D As p e n , C o l o r a d o 8 1 6 1 1 FOR PLANNING & APPROVALS PURPOSES ONLY, NOT FOR CONSTRUCTION approval: 98 SF 12 PLAN VIEWPROFILE VIEW TYPICAL IRRIGATION CONTROLLER GROUNDING ROD OR PLATE INSTALLATION 14 TYPICAL TRENCHING DETAIL 15 TYPICAL SLEEVING DETAIL13WALL MOUNT CONTROLLER ASSEMBLY 10 11PVC TECHLINE CONNECTION SUBSURFACE DRIP ASSEMBLY IN TURF AREAS IRRIGATION DETAILS 07/14/2020