Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.401 Castle Creek Rd.0018-2024-BCOM (10)
Owner: Aspen Valley Hospital 401 Castle Creek Road, Aspen, CO 81611 Architect: The S/L/A/M Collaborative 1900 Grant Street, Suite 800, Denver, CO 80203 MEP Engineers: Specialized Engineering Solutions (SES) 6143 S. Willow Drive, Suite 405, Englewood, CO 80111 Atlanta, GA Boston, MA Los Angeles, CA Proj No. : Date: Binding: Issued for: NUCLEAR MEDICINE / CT IMAGING RENOVATION Glastonbury, CTDenver, CO Philadelphia, PAIowa City, IA Orlando, FL (720) 946-0276 Structural Engineers: JVA Engineering 1512 Larimer Street, Suite 710, Denver, CO 80202 1/26/2024 23289 CONSTRUCTION DOCUMENTS 11/08/2024 @ AT A.B. ANCHOR BOLT A/C AIR CONDITIONING ACOUST ACOUSTICAL AC. T. ACOUSTIC TILE ACT ACTUAL ACP ACOUSTIC CEILING PANEL A.D. AREA DRAIN ADDL ADDITIONAL ADJ ADJUSTABLE / ADJUST A.F.F. ABOVE FINISHED FLOOR AGGR AGGREGATE A.H.U. AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE ARCH ARCHITECTURAL ASPH ASPHALT A.T. ASPHALT TILE L ANGLE B.C. BRICK COURSE B/C BOTTOM OF CURB BD BOARD B.E.J. BRICK (BLOCK) EXPANSION JOINT B.F. BOTTOM OF FOOTING BITUM BITUMINOUS BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BEAM B.M. BENCH MARK BOT BOTTOM B.P. BOTTOM OF POCKET B.PL. BEARING PLATE / BASE PLATE BRK BRICK B.S. BOTH SIDES B.U.R. BUILT UP ROOFING B/W BOTTOM OF WALL B.W.R. BOTH WAYS WALL CAB CABINET C.B. CATCH BASIN CEM CEMENT CER CERAMIC C.F.M.F. COLD FORMED METAL FRAMING C.H. CABINET HEATER CHKBD CHALKBOARD C.I. CAST IRON C.J. CONTROL JOINT CLG. HT. CEILING HEIGHT CLO CLOSET CLR CLEAR CLRM CLASSROOM C.M.U. CONCRETE MASONRY UNIT CNTR COUNTER C.O. CLEAN OUT COL COLUMN COMP COMPACTED / COMPOSITION CONC CONCRETE CONF CONFERENCE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS C.L.L. CONTRACT LIMIT LINE CONT'R CONTRACTOR CONV CONVECTOR COORD COORDINATE CORR CORRIDOR C.P. CONTROL PANEL CPT CARPET C.R. CEILING REGISTER C.T. CERAMIC TILE CTR CENTER C.U.H. CABINET UNIT HEATER C.Y. CUBIC YARD DBL DOUBLE DEPT DEPARTMENT DET DETAIL D.F.S. DIRECT-APPLIED FINISH SYSTEM D.F. DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DISP DISPENSER DIV DIVISION D.L. DEAD LOAD DN DOWN D.O. DOOR OPENING DR DOOR DS DOWNSPOUT D.S.P. DRY STAND PIPE DWG DRAWING DWL DOWEL E EAST EA EACH E.B.F. EXISTING BOTTOM OF FOOTING E.C. EXPOSED CONSTRUCTION E.I.F.S. EXTERIOR INSULATION & FINISH SYSTEM E.J. EXPANSION JOINT E.J.C. EXPANSION JOINT COVER EL ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EMER EMERGENCY ENCL ENCLOSURE ENGR ENGINEER E.P. ELECTRICAL PANEL EQ EQUAL EQUIP EQUIPMENT E.W. EACH WAY E.W.C. ELECTRIC WATER COOLER EXH EXHAUST EXIST EXISTING EXP EXPANSION EXPD EXPANDED EXPO EXPOSED EXT EXTERIOR F.A. FIRE ALARM F.A.P. FIRE ALARM PANEL F.B. FOOTING BREAK F.BRK FACE BRICK F.D. FLOOR DRAIN FDN FOUNDATION F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET (WITH EXTINGUISHER PROVIDED) I.D. INSIDE DIAMETER I.F. INSIDE FACE INCAND INCANDESCENT INCL INCLUDE INSUL INSULATION INT INTERIOR INV INVERT I.P.S. IRON PIPE SIZE JAN JANITOR JST JOIST JT JOINT IT KITCHEN LAM LAMINATED LAV LAVATORY LCKR LOCKER L.F. LINEAR FOOT L.L. LIVE LOAD L.P. LOW POINT LT LIGHT MAS MASONRY MATL MATERIAL MAX MAXIMUM M.C. MASONRY COURSE MECH MECHANICAL MEMB MEMBRANE MET METAL MET T.P. METAL TOILET PARTITION MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS M.O. MASONRY OPENING MTD MOUNTED M.U. MASONRY UNIT MULL MULLION N NORTH N.I.C. NOT IN CONTRACT NO. NUMBER NOM NOMINAL N.R.C. NOISE REDUCTION COEFFICIENT N.T.S. NOT TO SCALE O/A OUTSIDE AIR O.C. ON CENTER O.D. OUTSIDE DIAMETER O.F. OUTSIDE FACE OFF OFFICE OH OVERHEAD OPNG OPENING OPP OPPOSITE O.H. OPPOSITE HAND OZ OUNCE PART PARTITION PL PLATE P.LAM PLASTIC LAMINATE PLS PLASTER PLYWD PLYWOOD PR PAIR PREFAB PREFABRICATED PROJ PROJECTION PROP PROPERTY PTD PAINTED P.T.D. PAPER TOWEL DISPENSER F.F. FACTORY FINISH F.H. FIRE HYDRANT F.H.C. FIRE HOSE CABINET F.H.P. FULL HEIGHT PARTITION FIN FINISH FIN FL FINISHED FLOOR FIXT FIXTURE FL FLOOR FLASH FLASHING FLEX FLEXIBLE FLUOR FLUORESCENT F.O.C. FACE OF CONCRETE F.O.F. FACE OF FINISH F.O.G. FACE OF GYPSUM BOARD F.O.M. FACE OF MASONRY F.O.S. FACE OF STUD FPD FLAT PANEL DISPLAY FPFG FIREPROOFING F.R. FIRE RATED F.R.T FIRE RETARDANT TREATED F.S. FULL SIZE FT FOOT OR FEET F.T.R. FINNED TUBE RADIATION FUR FURRING FUT FUTURE FW FOUNDATION WALL F.W.C. FABRIC WALL COVERING GA GAUGE GALV GALVANIZED G.B. GRAB BAR G.C. GENERAL CONTRACTOR GL GLASS GLZ GLAZE GND GROUND GRD GRADE GWB GYPSUM WALL BOARD GYP BD GYPSUM BOARD / GYPSUM BOARD UNIT H.B. HOSE BIBB HC HANDICAPPED H.C. HOLLOW CORE HD HEAD H.P. HIGH POINT HWD HARDWOOD HDW HARDWARE H.M. HOLLOW METAL HOR HORIZONTAL HTG HEATING HT HEIGHT HYD HYDRANT H&V HEATING AND VENTILATING H.U. HEATING UNIT Q.T. QUARRY TILE R RISER (RADIUS) R/A RETURN AIR RAD RADIATION R.B. RESILIENT BASE R.D. ROOF DRAIN RECPT RECEPTACLE REF REFERENCE REFL REFLECTED, REFLECTIVE REFR REFRIGERATOR REG REGISTER REINF REINFORCING REQ'D REQUIRED RES RESILIENT RET RETAINING REV REVISION RM ROOM R.O. ROUGH OPENING R.O.W. RIGHT OF WAY RS ROOF SYSTEM R.T. RUBBER TILE RV ROOF VENT R.W.L. RAIN WATER LEADER S SOUTH S.FPFG. SPRAYED-ON FIREPROOFING S.C. SOLID CORE S.C.D. SEAT COVER DISPENSER SCHED SCHEDULE S.D. SOAP DISPENSER SEC SECTION S.F. SQUARE FOOT S.G.F.T. STRUCTURAL GLAZED FACING TILE SH SHELF SHR SHOWER SHT SHEET SIM SIMILAR S.N.D. SANITARY NAPKIN DISPENSER S.N.R. SANITARY NAPKIN RECEPTACLE SPEC SPECIFICATIONS SPKLR SPRINKLER S.P.R. SINGLE PLY ROOF SQ SQUARE S.S SOLID SURFACE S.SK. SERVICE SINK S.STL. STAINLESS STEEL STA STATION STD STANDARD ST. FT. STEP FOOTING STIFF STIFFENERS STL STEEL STN STONE STOR STORAGE S. TR. SOUND TRANSMISSION STRUCT STRUCTURAL SURF SURFACE SUSP SUSPENDED SYM SYMMETRICAL T TREAD T & B TOP AND BOTTOM TB TACKBOARD T.B. TOWEL BAR T.C. TOP OF CURB TEL TELEPHONE TEMP TEMPERED TERR TERRAZZO T.F. TOP OF FOUNDATION T. & G. TONGUE AND GROOVE THK THICK THRES THRESHOLD T/P TOP OF PAVEMENT T.P.D. TOILET PAPER DISPENSER T/PR TOP OF PIER T/S TOP OF SLAB T/SH TOP OF SHELF T/STL TOP OF STEEL T/W TOP OF WALL TYP TYPICAL U.H. UNIT HEATER U.L. UNDERWRITER'S LABORATORY UNFIN UNFINISHED U.N.O. UNLESS NOTED OTHERWISE UR URINAL U.V. UNIT VENTILATOR V.B. VINYL BASE V.C.T. VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE V.F. VINYL FABRIC V.G. VERTICAL GRAIN V.I.F. VERIFY IN FIELD VOL VOLUME V.W.C. VINYL WALLCOVERING W WEST W/ WITH W.C. WATER CLOSET WD WOOD WND WINDOW W/O WITHOUT WP WATERPROOF W.P.T. WORKING POINT W.S. WALL SLEEVE WSCT WAINSCOT WT WEIGHT WWF WELDED WIRE FABRIC 1. OCCUPANCY CLASSIFICATION (IBC 302): 6. CONSTRUCTION TYPE CLASSIFICATION (IBC 602.0): 2. BUILDING HEIGHT W/ AUTOMATIC SPRINKLER SYSTEM IBC 503 & 504): 3. ACTUAL BUILDING AREA (IBC 502.1 & CHAPTER 2): 4. BUILDING AREA TABLE 506.2 (IBC 503 & 506): OCCUPANT LOADS OF INDIVIDUAL ROOMS (IBC 1004.1): 8. ENTIRE BUILDING SPRINKLERED (IBC 903.1): 11. CODES TO WHICH THIS PROJECT WAS DESIGNED: 10. EXIT ACCESS: 7. INTERIOR FINISHES (IBC TABLE 803.13): USE GROUP(S): ACCESSORY USE AREAS (IBC 508.2): MIXED OCCUPANCIES (IBC 508) ALLOWABLE HEIGHT IN STORIES/FEET: I-2 I-B NA 10 / 180' GROSS BUILDING AREA PER FLOOR: ALLOWABLE: PROVIDED: 75' (I-2 OCC.)< 75' EXIT ACCESS TRAVEL DISTANCE LIMITATIONS (IBC 1017.2) GROUP I-2 OCCUPANCY: INTERIOR EXIT STAIRWAYS ...CLASS B CORRIDORS AND ENCLOSURE ... - CLASS B ROOMS AND ENCLOSED SPACES - CLASS B OR C GROUP B OCCUPANCY: ROOMS AND ENCLOSED SPACES - CLASS C COMMON PATH OF TRAVEL LIMITATIONS (IBC 1006.2.1) MINIMUM CORRIDOR WIDTH (IBC 1020.2) ALLOWABLE: PROVIDED: 96" (I-2 OCC.) > 96" CORRIDOR DEAD END LIMITATION (IBC 1020.4) ALLOWABLE:PROVIDED:100' (B OCC.) < 100' ALLOWABLE: ALLOWABLE: MINIMUM TYPE OF CONSTRUCTION REQUIRED: I-BACTUAL TYPE OF CONSTRUCTION PROVIDED: NON-SEPARATED USES (IBC 508.3): SEPARATED USES (IBC 508.4): 1976DATE OF ORIGINAL CONSTRUCTION:2010 & 2013DATE OF ADDITIONS: ACTUAL HEIGHT IN STORIES/FEET:2 / 32' STORIES ABOVE GRADE:2 FIRST FLOOR - NEW CONSTRUCTION: FIRST FLOOR - EXISTING CONSTRUCTION: 133,557 SF 5598 SF SECOND FLOOR - NEW CONSTRUCTION: SECOND FLOOR - EXISTING CONSTRUCTION: 51,316 SF 0 SF FIRST FLOOR GROSS BUILDING AREA:139,155 SF SECOND FLOOR GROSS BUILDING AREA:51,316 SF SECOND FLOOR: FIRST FLOOR: DESIGN TOTAL FOR EACH FLOOR: NA 316 OCC. 9. OCCUPANCY LOAD - REFER TO FIRE SAFETY PLANS FOR SECOND FLOOR: FIRST FLOOR: TOTAL EXIT CAPACITY FOR EACH FLOOR: NA 930 OCC. DESIGN TOTAL FOR ENTIRE BUILDING: TOTAL EXIT CAPACITY FOR ENTIRE BUILDING: NA NA. YES PROVIDED:200' (I-2 OCC.)< 200' PROVIDED:300' (B OCC.)< 300' ALLOWABLE: PROVIDED:44" (B OCC. W/ BEDS) > 44" ALLOWABLE: PROVIDED: 20' (I-2 OCC.)< 20' ALLOWABLE:PROVIDED:50' (B OCC.) < 50' - 2021 INTERNATIONAL MECHANICAL CODE - IMC - 2021 INTERNATIONAL PLUMBING CODE - IPC - 2021 ASPEN ENERGY CODE - 2023 NATIONAL ELECTRICAL CODE - 2009 ICC/ANSI A117.1 ACCESSIBLE and USABLE BUILDINGS and FACILITIES ANSI - 2021 INTERNATIONAL EXISTING BUILDING CODE IEBC - 2021 INTERNATIONAL BUILDING CODE IBC - 2021 INTERNATIONAL FIRE CODE - IFC - 2012 NFPA 101 LIFE SAFETY CODE - 2018 FGI - GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND OUT-PATIENT FACILITIES - 2021 INTERNATIONAL FUEL GAS CODE - IFGC OCCUPANCY GROUP I-2, SM = UL 1005.3.1 Where stairways serve more than one story, only the occupant load of each story considered individually shall be used in calculating the required capacity of the stairways serving that story. INTERIOR EXIT STAIRWAYS ETC.CLASS B CORRIDORS AND ENCLOSURE FOR EXIT - CLASS C I-2 5. FIRE RESISTANCE RATED REQUIREMENTS FOR BUILDING ELEMENT BEARING WALLS NONBEARING WALLS AND PARTITIONS EXTERIOR FLOOR CONSTRUCTION: INCLUDING SUPPORTING BEAMS AND JOISTS STRUCTURAL FRAME, INCLUDING COLUMNS, GIRDERS, TRUSSES ROOF CONSTRUCTION: INCLUDING SUPPORTING BEAMS AND JOISTS SHAFTS - EXIT SHAFTS - OTHER CORRIDOR SEPARATION OCCUPANCY SEPARATION INCIDENTAL USE SEPARATION PARTY/FIRE WALL SEPARATION SMOKE BARRIER SEPARATION TENANT SEPARATION PEDESTRIAN WALKWAYS EXTERIOR INTERIOR INT. CARRYING ROOF ONLY NORTH EAST WEST SOUTH INTERIOR NORTH EAST WEST SOUTH FIRE SEP. DIST. (FEET) RATING REQ'D PROVIDED 2 HR 30 FT NR = NO RATING N/A = NOT APPLICABLE, CONDITION NOT PRESENT IN DESIGN 1 HR = 1 HOUR RATING 2 HR = 2 HOUR RATING 3 HR = 3 HOUR RATING 0 HR = UNRATED SMOKE PARTITION BUILDING ELEMENTS (CBC TABLE 601): 30 FT 30 FT 30 FT 2 HR 2 HR 2 HR 2 HR 2 HR 2 HR 2 HR 2 HR 2 HR 2 HR 2 HR 1 HR 1 HR 0 HR EXIST. 0 HR 0 HR 0 HR EXIST. 0 HR 0 HR 0 HR 0 HR 2 HR N/A 1 HR 1 HR 1 HR 1 HR 1 HR 1 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR N/A N/A 1HS 1HS N/A N/A 0 HR 0 HR Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 12" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 1/25/2024 3:11:25 PM GI01 1/26/2024 23289 GENERAL INFORMATION BO DC © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . CODE INFORMATION DRAWING LISTABBREVIATIONS GENERAL C01 COVER SHEET GI01 GENERAL INFORMATION GC101 FIRST FLOOR FIRE SAFETY PLAN ARCHITECTURAL AD101 FIRST FLOOR DEMOLITION PLAN A101 FIRST FLOOR PLAN A201 FIRST FLOOR REFLECTED CEILING PLAN A600 PARTITION TYPES A601 DOOR SCHEDULE, DOOR AND FRAME TYPES A701 INTERIOR ELEVATIONS A800 INTERIOR DETAILS A900 FINISH AND EQUIPMENT PLAN MECHANICAL M000 MECHANICAL SYMBOLS AND ABBREVIATIONS M001 MECHANICAL SPECIFICATIONS M002 MECHANICAL SPECIFICATIONS M003 MECHANICAL SPECIFICATIONS M101 MECHANICAL & PIPING DEMOLITION M500 MECHANICAL DETAILS M600 MECHANICAL SCHEDULES MH201 NEW FLOOR PLAN - DUCTWORK MP201 NEW FLOOR PLAN - HYDRONIC PIPING PLUMBING P000 PLUMBING SYMBOLS AND ABBREVIATIONS P101 PLUMBING & MEDICAL GAS DEMOLITION P500 PLUMBING DETAILS P600 PLUMBING SCHEDULES PG201 NEW FLOOR PLAN - MEDICAL GAS PP201 NEW FLOOR PLAN - PLUMBING ELECTRICAL E000 ELECTRICAL SYMBOLS AND ABREVIATIONS E001 ELECTRICAL SPECIFICATIONS E101 ELECTRICAL DEMOLITION EL201 NEW FLOOR PLAN - LIGHTING EP201 NEW FLOOR PLAN - POWER E300 ENLARGED POWER PLAN E500 ONE-LINE DIAGRAM E600 ELECTRICAL DETAILS E700 ELECTRICAL SCHEDULES 1/26/2024 CONSTRUCTION DOCUMENTS 1/26/24 11/08/2024 72 FT TO SUITE EXIT 73 FT TO SUITE EXIT NON-FIRE RATED SMOKE PARTITION FIRE SAFETY LEGEND 30 MINUTE FIRE PARTITION 30 MINUTE SMOKE BARRIER 1 HOUR EXTERIOR WALL 1 HOUR FIRE BARRIER 1 HOUR FIRE AND SMOKE BARRIER 1 HOUR FIRE PARTITION 2 HOUR EXTERIOR WALL 2 HOUR FIRE WALL 2 HOUR FIRE BARRIER 2 HOUR FIRE AND SMOKE BARRIER 3 HOUR EXTERIOR WALL 3 HOUR FIRE WALL 3 HOUR FIRE BARRIER 3 HOUR FIRE AND SMOKE BARRIER 4 HOUR EXTERIOR WALL 4 HOUR FIRE WALL 4 HOUR FIRE BARRIER 4 HOUR FIRE AND SMOKE BARRIER FIRE SAFETY LEGEND REFER TO FLOOR PLANS AND WALL PARTITION TYPES (DRAWING A601) FOR SPECIFIC PARTITION DETAILS AND LOCATIONS ROOM OCCUPANT LOAD AREA IN SQ. FT. OCCUPANT LOAD FACTOR (IBC TABLE 1004.1.2) 15 DIRECTION OF TRAVEL WITH ACCUMULATED OCCUPANT LOAD 146'MAXIMUM TRAVEL DISTANCE FROM FURTHEST POINT AREA OF REFUGE NON ACCESSIBLE EXIT ACCESSIBLE EXIT REQUIRED EXIT FOR BALANCED EGRESS CAPACITY PER 1005.1.1RE FIRE SAFETY PLAN GENERAL NOTES 1. FIRE BARRIERS, FIRE WALLS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS SHALL BE LABELED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING AND ATTIC SPACES WITH PAINTED SIGNAGE. INCIDENTAL USE ROOM V FIRE VALVE/ STANDPIPE F FIRE EXTINGUISHER IN CABINET F FIRE EXTINGUISHER ON WALL BRACKET Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " As indicated Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 1/25/2024 3:11:25 PM GC101 1/26/2024 23289 FIRST FLOOR FIRE SAFETY PLAN © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/4" = 1'-0"1C LIFE SAFETY - FIRST FLOOR 1/26/2024 CONSTRUCTION DOCUMENTS FIRE SAFETY PLAN GENERAL NOTES 1. THE SCOPE OF THIS PROJECT INCLUDES MINOR RENOVATION. THERE IS NO CHANGE IN THE EXISTING BUILDING TYPE, OCCUPANCY, AND EGRESS DIRECTION OR CAPACITY. 2. FIRE BARRIERS, FIRE WALLS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS SHALL BE LABELED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING AND ATTIC SPACES WITH PAINTED SIGNAGE. 1/26/24 11/08/2024 REMOVE EXISTING CONSTRUCTION DEMOLITION PLAN GRAPHIC LEGEND EXISTING CONSTRUCTION TO REMAIN NOT IN SCOPE 18 18 NN OO AA AA PP 20 20 22 22 21.4 21.4 24 24 25 25 22.8 22.8 19 19 19.4 19.4 21 21 23 23 P.9 P.9 QQ Q.7 Q.7 3.023.02 8.06 8.01 8.01 8.01 8.10 8.11 9.01 9.01 9.01 9.01 9.01 9.01 9.02 6.01 6.01 6.07 9.10 9.10 9.10 9.14 9.14 9.14 9.14 9.14 9.14 N.M. / CT IMAGING 1622 N.M .TECH 1612 CONTRAST MEDIA PREP AREA 1613 6.01 6.01 9.03 9.03 9.14 9.03 3.01 EXISTING MED GAS TO REMAIN 12.03 SAWCUT LINE SAWCUT LINE EXISTING CONCRETE SLAB ON GRADE #4 X 2'-0" LONG @ 18" OC DOWELS- GROUT 6" INTO EXISTING SLAB W/ ADHESIVE ANCHORING SYSTEM UNDERCUT EXISTING SLAB SAW CUT AND REMOVE EXISTING SLAB ON GRADE TO ALLOW FOR NEW TRENCH EXCAVATION AND NEW UTILIY PIPE/CONDUIT INSTALLATION - REPLACE REMOVED SLAB WITH NEW NORMAL WEIGHT CONCRETE SLAB OF THE SAME THICKNESS OR 5" MIN. COMPACTED GRANULAR FILL LIMIT OF EXCAVATION NEW PIPE/CONDUIT - SEE MEP DRAWINGS DEMOLITION GENERAL NOTES A.REFER TO DIVISION 02 SECTION "STRUCTURE DEMOLITION" AND/OR "SELECTIVE STRUCTURE DEMOLITION" FOR ADDITIONAL DEMOLITION REQUIREMENTS. B.COORDINATE PROPOSED METHODS AND OPERATIONS OF DEMOLITION WITH OWNER'S DESIGNATED REPRESENTATIVE PRIOR TO START OF DEMOLITION WORK. INCLUDE IN SCHEDULE COORDINATION FOR SHUT-OFF, CAPPING AND CONTINUATION OF UTILITY SERVICES AS REQUIRED. C.DEMOLITION WORK SHALL BE PHASED. REFER TO DIVISION 01 SECTION "SUMMARY" FOR DESCRIPTION OF PHASING REQUIREMENTS. D.INTERRUPTIONS IN DAILY OPERATIONS MUST BE COORDINATED IN ADVANCE WITH OWNER'S DESIGNATED REPRESENTATIVE. THIS SHALL INCLUDE SERVICE INTERRUPTIONS AND CONNECTIONS, RELOCATION OF OCCUPANTS, REMOVAL OF EQUIPMENT, SHIFTS IN LOCATION OF WORK, MECHANICAL AND ELECTRICAL DISRUPTION, ETC. ANY OF THE ABOVE INTERRUPTIONS REQUIRE A MINIMUM OF THREE FULL WORKING DAYS NOTICE TO THE OWNER. FRIDAY P.M. NOTICE FOR MONDAY A.M. INTERRUPTIONS WILL NOT BE ACCEPTABLE. E.CONDUCT DEMOLITION AND DEBRIS REMOVAL IN A SAFE MANNER TO MINIMIZE INTERFERENCE WITH CORRIDORS, HALLS, STAIRS, AND OTHER ADJACENT FACILITIES AND TO AVOID DAMAGE TO SAME. DO NOT CLOSE OR OBSTRUCT TRAFFIC WAYS WITHOUT PERMISSION OF THE OWNER. F. ERECT TEMPORARY ENCLOSURE(S) AROUND ALL EXTERIOR OPENINGS CREATED IN THE BUILDING. THE BUILDING SHALL BE LEFT WEATHER-TIGHT AND SECURE AT THE END OF EACH WORKDAY. G.PROVIDE TEMPORARY DUST ENCLOSURES AROUND ALL AREAS OF WORK. PREVENT DUST, DEBRIS, ETC. FROM REACHING ADJACENT AREAS OF BUILDING. H.REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL DEMOLITION REQUIREMENTS. I. ALL SALVAGEABLE MATERIAL AND EQUIPMENT SHOWN OR SCHEDULED TO BE REMAIN AS THE PROPERTY OF THE OWNER OR NOT DISCLAIMED BY THE OWNER PRIOR TO THE BEGINNING OF DEMOLITION WORK SHALL BE CAREFULLY REMOVED AND STORED WHERE DIRECTED BY THE OWNER. THE CONTRACTOR SHALL VERIFY WITH THE OWNER ALL ITEMS TO BE SALVAGED. J. ALL SALVAGEABLE MATERIAL AND EQUIPMENT SCHEDULED TO BE REMOVED AND NOT REUSED AND DISCLAIMED BY THE OWNER SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE TRANSPORTED FROM THE SITE AS THEY ARE REMOVED. STORAGE OR SALE OF REMOVED ITEMS ON SITE WILL NOT BE PERMITTED. K.VERIFY SAVING AND RE-USE OF ALL MISCELLANEOUS ITEMS AND EQUIPMENT NOT SPECIFICALLY LISTED ON THE DRAWINGS OR IN THE SPECIFICATIONS WITH THE OWNER PRIOR TO DEMOLITION. L. UNLESS OTHERWISE INDICATED ON THE DRAWINGS OR THE FINISH SCHEDULE, ALL PORTIONS OF THE EXISTING BUILDING (INCLUDING FINISHES) DISTURBED BY DEMOLITION OF EXISTING CONSTRUCTION AND/OR INSTALLATION OF NEW CONSTRUCTION, INCLUDING MECHANICAL AND ELECTRICAL WORK, SHALL BE REPAIRED AS REQUIRED AND RETURNED TO ITS ORIGINAL UNDISTURBED CONDITION OR BETTER. M.REMOVE ALL EXISTING WALL CONSTRUCTION, MILLWORK, EQUIPMENT, ETC. SHOWN DASHED ON THIS DRAWING IN ITS ENTIRETY TO THE EXTENT SHOWN ON THE DRAWINGS. PARTITIONS SHALL BE REMOVED FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE UNLESS OTHERWISE NOTED. N.AT EXISTING INTERSECTING WALL WHERE ONE WALL HAS BEEN DEMOLISHED, PREPARE NEWLY EXPOSED AREA OF WALL TO MATCH EXISTING ADJACENT SURFACES. O.EXISTING WALLS INDICATED TO REMAIN ARE FOR PURPOSES OF ECONOMY ONLY. CONTRACTOR MAY ASSUME, IF MORE EXPEDIENT FOR CONSTRUCTION OR LESS EXPENSIVE FOR THE OWNER, THAT EXISTING CONSTRUCTION MAY BE REMOVED AND REPLACED WITH NEW CONSTRUCTION ACCEPTABLE TO THE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " As indicated Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 1/25/2024 3:11:24 PM AD101 1/26/2024 23289 FIRST FLOOR DEMOLITION PLAN BO DC © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/4" = 1'-0"1C Nuc-Med CT Rooms Demolition Plan 1" = 1'-0"1D TYPICAL SLAB TRENCH DETAIL 3.01 SAWCUT AND REMOVE PORTION OF EXISTING CONCRETE SLAB AND EXCAVATE AS REQUIRED TO ACCOMMODATE INSTALLATION OF NEW UNDERSLAB UTILITY PIPING. REFER TO PLUMBING DRAWINGS FOR EXTENT OF NEW UNDERSLAB PIPING. 3.02 SAWCUT AND REMOVE PORTION OF EXISTING CONCRETE SLAB AND EXCAVATE AS REQUIRED TO ACCOMMODATE INSTALLATION OF NEW UNDERSLAB ELECTRICAL CONDUIT AND WIRING. REFER TO ELECTRICAL DRAWINGS FOR EXTENT OF NEW UNDERSLAB ELECTRICAL CONDUIT AND WIRING. 6.01 REMOVE EXISTING MILLWORK, CASEWORK, AND SHELVING. 6.07 CAREFULLY REMOVE EXISTING COUNTERTOP AND CABINETS, LABEL AND STORE FOR RE-USE IN NEW CONTRAST MEDIA PREP AREA 8.01 REMOVE EXISTING DOOR, FRAME, AND HARDWARE. 8.06 REMOVE EXISTING HOLLOW METAL BORROWED LITE AND GLAZING. 8.10 VERIFY IF EXISTING DOOR IS LEAD LINED, IF IT IS NOT THAN REMOVE DOOR FRAME AND HARDWARE, BUT KEEP EXISTING CARD READER IN PLACE IN PREPERATION FOR NEW LEAD LINED DOOR AND FRAME. 8.11 EXISTING DOOR TO REMAIN, WITH DOOR LOCKED REMOVE INTERIOR SIDE HARDWARE AND COVER OPENING WITH GYP STUD INFILL AND PAINT TO MATCH ADJACENT WALLS. 9.01 REMOVE EXISTING METAL STUD AND GYPSUM BOARD PARTITION(S) ENTIRELY TO EXTENT SHOWN ON DRAWINGS. 9.02 REMOVE PORTION OF EXISTING PARTITION AS INDICATED ON PLANS OR INDICATED IN DETAILS. FOR PARTIAL REMOVAL, MAKE NEAT CUTS BETWEEN FINISHES TO REMAIN AND TO BE REMOVED. COORDINATE WITH NEW CONSTRUCTION. 9.03 REMOVE EXISTING SUSPENDED CEILING GRID AND PANEL SYSTEM IN ITS ENTIRETY. 9.10 REMOVE EXISTING VINYL FLOORING AND RESILIENT BASE. 9.14 REMOVE INTERIOR SIDE GYPSUM ONLY TO PREPARE WALL FOR NEW LEAD SHIELDING AND ADD SOUND BATT INSULATION IF NOT EXISTING. 12.03 REMOVE AND SALVAGE EXISTING HAND SINK FOR RELOCATION. 1/26/24 11/08/2024 A NEW WALL CONSTRUCTION FLOOR PLAN GRAPHIC LEGEND EXISTING WALL CONSTRUCTION TO REMAIN NOT IN SCOPE 18 18 NN OO AA AA PP 20 20 22 22 21.4 21.4 24 24 25 25 22.8 22.8 19 19 19.4 19.4 21 21 23 23 P.9 P.9 QQ Q.7 Q.7 MED (EXISTING) X60 ADMIN ASSISTANT (EXISTING) X70 DIRECTOR OF MARKETING (EXISTING) X72 STORAGE (EXISTING) 1809 GENERAL COUNSELOR (EXISTING) X74 CHECK-IN/ WAITING (EXISTING) 1601 TECH/WORK (EXISTING) 1602 LOCKERS (EXISTING) 1610 PATIENT TOILET (EXISTING) 1625 DIAGNOSTICS (EXISTING) 1603 DIRECTOR (EXISTING) 1609 STRESS TEST (EXISTING) 1611 N.M. WAITING (EXISTING) 1614 IDF 2008 ELECTRICAL 2006 OFFICE 2010 OFFICE (EXISTING) 119 CORRIDOR (EXISTING) 2004 CLOSET 2009 MAIL (EXISTING) 2061 TOILET 2446 CLEAR 5' - 0 " 1 3 ' - 8 5 / 8 " 1' - 1 1 / 2 " 26'-3 7/8" N.M .TECH 1612 CONTRAST MEDIA PREP AREA 1613 N.M. / CT IMAGING 1622 11'-0" 8'-9" 1'-0" 7'-0" 4'-6" 11'-7" 6' - 8 " LINEN STORAGE A701 1A 7' - 0 " 8'-0" A7013A 1C 2' - 6 " 1'-4" MGAP MEDICAL GASSES (O2 AND VAC) POSITIONING POINT V. I . F . 7' - 7 1 / 4 " CEILING MOUNTED CONTRAST INJECTOR HEAD, FINAL LOCATION TO BE APPROVED BY OWNER 1LB 1LB 1LA 1LB 1LA 1LA 1 1612 1622A 1613 2'-1" 1622B CARD READER, EXISTING TO REMAIN 1622C 1LA EXISTING MED GAS TO REMAIN E.P. (2) WALL MOUNTED STEAM GENERATORS 6' - 0 " 2'-6" 6" M I N . 6" MIN.1 1614C 1 6" M I N . 2" M I N . FLOOR PLAN GENERAL NOTES 1. REFER TO DWG. GI01 FOR LIST OF TYPICAL ABBREVIATIONS AND TYPICAL ARCHITECTURAL GRAPHIC LEGENDS AND SYMBOLS. 2. REFER TO DWG. A600 FOR TYPICAL PARTITION TYPES AND DETAILS INDICATED. ALL PARTITIONS SHALL BE TYPE 1 U.O.N. ALL MASONRY PARTITIONS SHALL BE TYPE M8 U.O.N. 3. REFER TO THE FIRE SAFETY PLANS GC101 FOR LOCATIONS OF FIRE-RESISTANCE RATED PARTITIONS AND NON-FIRE- RESISTANCE RATED SMOKE PARTITIONS. 4. ALIGN PARTITIONS WITH COLUMN OR MULLION CENTERLINE, UNLESS OTHERWISE NOTED. 5. DIMENSIONS ARE FROM FACE OF WALL TO FACE OF WALL, (I.E. FACE OF GYPSUM BOARD OR MASONRY) OR FROM FACE OF EXISTING CONDITION OR FROM COLUMN CENTERLINE, UNLESS OTHERWISE NOTED. DIMENSIONS NOTED AS "CLEAR" SHALL BE FROM FINISH FACE TO FINISH FACE, (ie. FACE OF CERAMIC TILE TO FACE OF CERAMIC TILE). VERIFY ALL EXISTING DIMENSIONS IN THE FIELD. 6. ALL MASONRY DIMENSIONS, INDICATED "M.O.", ARE NOMINAL DIMENSIONS, UNLESS OTHERWISE NOTED. ACTUAL MASONRY OPENING DIMENSION = NOMINAL MASONRY OPENING DIMENSION + ONE MORTAR JOINT (I.E., 4'-0" M.O. = 4'-0" + ?" ACTUAL OPENING DIMENSION). 7. REFER TO PLAN ENLARGEMENTS FOR ADDITIONAL DIMENSIONS. 8. REFER TO DWG. A601 FOR DOOR AND FRAME DETAILS. PROVIDE MINIMUM 4-INCH CLEARANCE FROM FACE OF DOOR JAMB TO FACE OF ADJACENT WALL, UNLESS OTHERWISE NOTED. 9. REFER TO DWG. A701 FOR TYPICAL MOUNTING LOCATIONS AND HEIGHTS FOR TOILET ACCESSORIES, EQUIPMENT, WALL SPECIALTY DESIGNATIONS, VISUAL DISPLAY BOARDS, ETC.; TYPICAL TOILET ROOM ELEVATIONS AND TOILET ACCESSORY SCHEDULE. 10. REFER TO DWG. A601 FOR THE DOOR AND FRAME SCHEDULE AND A900 FOR THE FINISH SCHEDULE. 11. PROVIDE FIRE-TREATED WOOD BLOCKING OR MINIMUM 0.0312-INCH THICK STEEL FLAT STRAP AND BACKING PLATE AT, BUT NOT LIMITED TO, THE FOLLOWING LOCATIONS: TOILET ACCESSORIES, CASEWORK, MILLWORK, DOOR WALL BUMPERS, AND ALL OTHER WALL MOUNTED EQUIPMENT OR DEVICES. 12. ALL EXISTING PARTITIONS INDICATED ON THE FIRE SAFETY PLANS TO BE SMOKE PARTITIONS, SMOKE BARRIERS, OR FIRE- RATED PARTITIONS THAT DO NOT CURRENTLY EXTEND TO UNDERSIDE OF FLOOR SLAB SHALL BE MODIFIED TO EXTEND TO SLAB AND SHALL COMPLY WITH DETAILS SHOWN FOR NEW PARTITIONS. ALL PENETRATIONS OR VOIDS SHALL BE SEALED SMOKE-TIGHT AND/OR BE FIRE-STOPPED AS REQUIRED. 13. REFER TO THE EQUIPMENT PLANS FOR VISUAL DISPLAY BOARD, RESIDENTIAL APPLIANCE, FIXED AUDITORIUM SEATING, PROJECTION SCREEN AND TOILET ACCESSORY LOCATIONS. REFER TO THE EQUIPMENT PLANS FOR EQUIPMENT LOCATIONS AND SCHEDULE. 14. REFER TO THE FINISH PLANS FOR FLOOR PATTERNS. 15. FLOOR PATCH AND FLOOR LEVELING: REPAIR EXISTING TOPPING SLAB AND CONCRETE FLOOR AT DEMOLITION OF WALLS AND AT ALL OTHER LOCATIONS AS REQUIRED. REFER TO DWG. AD101 FOR ADDITIONAL INFORMATION. 16. PATCHING TO MATCH EXISTING: A)PROVIDE ALL OPENINGS REQUIRED FOR ALL TRADES AND PATCH TO MATCH EXISTING, AT EXISTING CONSTRUCTION ALTERED OR DISTURBED BY THE INSTALLATION, RELOCATION, OR REMOVAL OF HEATING, VENTILATING, AIR CONDITIONING, PLUMBING AND/OR ELECTRICAL EQUIPMENT AND DEVICES. B)PATCH TO MATCH EXISTING (PTME), ALL AREAS ADJACENT TO, OR DISTURBED BY, NEW CONSTRUCTION OR EXISTING CONSTRUCTION TO BE REMOVED. PATCH TO MATCH INCLUDES FINISH MATERIAL (PAINT OR VWC OR CERAMIC TILE... ETC.) TO MATCH EXISTING. C)PATCH ALL DEFECTS IN, AND FINISH TO MATCH EXISTING, ALL AREAS WHICH ARE TO RECEIVE NEW MATERIALS, FINISHES AND ITEMS CALLED FOR IN THE CONTRACT DOCUMENTS. PREPARE ALL EXISTING SURFACES TO RECEIVE NEW FINISHES AS REQUIRED. Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " As indicated Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 8/21/2024 11:58:36 AM A101 3/1/2024 23289 FIRST FLOOR PLAN BO DC © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/4" = 1'-0"1C Nuc-Med CT Rooms New Work 1/26/2024 CONSTRUCTION DOCUMENTS 1 5/8/2024 NM RFI 1 2 8/21/2024 NM RFI 4 2 11/08/2024 2X2 SUPPLY DIFFUSER 2X2 RETURN DIFFUSER CEILING PLAN GRAPHIC LEGEND 2 ' X 4' CEILING RECESSED 2 ' X 2' CEILING RECESSED HVAC FIXTURES NOT IN SCOPE CEILING TYPESHATCHES 2 ' X 2' ACCOUSTIC PANEL CEILING 2' X 4' ACCOUSTIC PANEL CEILING PAINTED GYPBOARD CEILING LIGHT FIXTURES 4" RECESSED DOWNLIGHT 18 18 NN OO AA AA PP 20 20 22 22 21.4 21.4 24 24 25 25 22.8 22.8 19 19 19.4 19.4 21 21 23 23 P.9 P.9 QQ Q.7 Q.7 BASIS OF DESIGN: NEWMAT STRETCH MEMBRANE CEILING AND LIGHT FIXTURE 9'-0"ACT 9'-0"ACT 9'-0"ACT N.M. / CT IMAGING 1622 N.M .TECH 1612 CONTRAST MEDIA PREP AREA 1613 CONTRAST INJECTOR, CEILING MOUNT. FINAL LOCATION TO BE APPROVED BY OWNER 7'-6"PGB1 8'-2"PGB1 9'-0"PGB1 2'-0" EQ . E Q . 2'-0" EQ E Q 11'-7" 6' - 8 " UNDERCOUNTER LIGHTS BELOW UPPER CABINETS, REF. ELECTRICAL 4' - 0 " 3'-9" X-RAY IN USE LIGHT X-RAY IN USE LIGHT Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " As indicated Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 1/25/2024 3:11:14 PM A201 1/26/2024 23289 FIRST FLOOR REFLECTED CEILING PLAN BO DC © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/4" = 1'-0"1C FIRST FLOOR REFLECTED CEILING PLAN 1/26/2024 CONSTRUCTION DOCUMENTS 1/26/24 11/08/2024 CEILING HEIGHT EL: (VARIES - SEE RCP) CEILING HEIGHT EL: (VARIES - SEE RCP) 2 1/2" METAL STUD FRAMING AT 16" O.C. BRACED TO UNDERSIDE OF SLAB ABOVE. SUSPENDED ACOUSTIC TILE CEILING WALL ANGLE 5/8" GWB CHANNEL MOLDING CORNER BEAD 5/8" GWB ON DRYWALL SYSTEM 6" UNDERSIDE OF CONCRETE FLOOR DECK LIGHT GAUGE CLIP ANGLE SIZE AND GAUGE AS REQUIRED SPACED 4'-0" O.C. KICKER - SIZE AND GAUGE AS REQUIRED U-CHANNEL - SIZE AND GAUGE AS REQUIRED GIRT - SIZE AND GAUGE AS REQUIRED METAL STUD FRAMING SEE RCP FOR SOFFIT DETAIL NOTE: AT PLAIN ROOF STEEL DECKS, PROVIDE ADEQUATE SUBFRAMING SPANNING BETWEEN BEAMS/ JOISTS. GENERAL NOTE APPLICABLE TO ALL CEILING DETAILS WHERE CEILING, SOFFITS AND RELATED SYSTEMS (INCLUDING: MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION ITEMS) ARE TO BE HUNG FROM OVERHEAD STRUCTURE, FASTEN HANGERS DIRECTLY TO ANY OF THE FOLLOWING: 1. STRUCTURAL STEEL FRAMING MEMBERS OR ADDED SECONDARY MEMBERS AS NOTED BELOW. 2. CONCRETE FLOOR OR ROOF CONSTRUCTION (CAST-IN-PLACE, PRECAST, OR CONCRETE FILLED STEEL DECKS DO NOT HANG DIRECTLY FROM PLAIN ROOF STEEL DECKS (UNLESS EOR CONFIRMS THAT DECK HAS BEEN DESIGNED TO SUPPORT HANGING LOADS). IN LOCATIONS WHERE PLAIN ROOF STEEL DECK (NO CONCRETE FILL) IS OVERHEAD, HANG ONLY FROM STRUCTURAL STEEL FRAMING MEMBERS OR PROVIDE SECONDARY STEEL FRAMING MEMBERS OF ADEQUATE DESIGN (SPANNING BETWEEN BUILDING STRUCTURAL STEEL FRAMING MEMBERS) AS REQUIRED. TO B E D E T E R M I N E D B Y VA R I E S SU P P O R T C O N T R A C T O R EQUIPMENT SUPPLIER DETERMINED BY VARIES SEE GENERAL SUPPORT SYSTEM NOTES 1-6 ON THIS SHEET UNISTRUT LOWER RAILS UNISTRUT VERTICAL DROPS TYPICAL OF FOUR 1/2" THREADED ROD DROPS TYPICAL OF FOUR UNISTRUT CROSS TIE UNISTRUT DIAGONAL BRACING (FOUR PLACES) MOUNTING PLATE (SIZE AND DETAILS DETERMINED BY EQUIPMENT SUPPLIER) LEVELED WITH BOLTS THRU LEVELING PLATE C EQUIPMENT L C EQUIPMENT L B AB A GENERAL SUPPORT SYSTEM NOTES 1. MEDICAL SUPPORT ASSEMBLIES SHOWN ARE GENERIC IN NATURE TO SHOW THE PROPOSED GEOMETRY AND GENERAL CONFIGURATION OF THE SYSTEM ANTICIPATED. 2. ALL COMPONENT SIZES IDENTIFIED AS WELL AS RELATIVE POSITION MUST BE CONFIRMED THROUGH THE DESIGN OF THE INDIVIDUAL SYSTEM BY THE CONTRACTOR. SIZES, SPACING, ETC. SHOWN ARE NOT TO BE CONSTRUED AS BEING ADEQUATE FOR THE REQUIRED SUPPORT, BUT RATHER ARE ONLY TO INDICATE POTENTIAL SPATIAL REQUIREMENTS FOR PRELIMINARY COORDINATION. SIZES MAY VARY WITH FINAL DESIGN CALCULATIONS. 3. FINAL SPACING AND LOCATION OF CARRYING RAILS, SUPPORT RODS, ETC., TO BE DETERMINED FROM CUTS/DATA SHEETS FROM EQUIPMENT VENDORS. 4. DESIGN OF SIZE, QUANTITY AND SPACING OF FASTENERS TO STRUCTURAL MEMBERS IS BY THE CONTRACTOR. REFER TO SPECIFICATIONS FOR DELEGATED DESIGN REQUIREMENTS AND TOLERANCES. 5. SUPPORT CONTRACTOR SHALL COORDINATE WITH EQUIPMENT SUPPLIER TO ENSURE LOCATION OF A STRUCTURE DOES NOT INTERFERE WITH MOUNTING OR OPERATION OF BOOM AND DOES NOT INTERFERE WITH ANY HOLES OF INTERFACE PLATE. 6. SUPPORT CONTRACTOR SHALL PROVIDE SUPPORT AND CONNECTION CALCULATIONS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER LISENCED TO PRACTICE IN THE STATE OF COLORADO TO STRUCTURAL ENGINEER OF RECORD FOR REVIEW. SUPPORT CONTRACTOR SHALL DESIGN SUPPORT FOR LOADS, DEFLECTION AND ROTATION REQUIREMENTS FOR EQUIPMENT SUPPLIERS RECOMMENDATIONS X' - X " VA R I E S SE E R E F L E C T E D C E I L I N G P L A N SECTION A-A CO O R D I N A T E WI T H EQ U I P M E N T SU P P L I E R UNISTRUT ANGULAR FITTING CONNECTION TO BE DESIGNED BY SUPPORT CONTRACTOR (TYP.) UNISTRUT WING FITTING ATTACHED TO CONCRETE SLAB WITH EXPANSION BOLTS (TO BE DETERMINED BY SUPPORT CONTRACTOR) CONCRETE SLAB ABOVE UNISTRUT DIAGONAL BRACING UNISTRUT VERTICAL DROPS TYPICAL OF FOUR UNISTRUT CROSS TIE UNISTRUT LOWER RAILS THREADED ROD DROPS FINISH CEILING (SEE RCP) STEEL INTERFACE PLATE BY EQUIPMENT SUPPLIER MOUNTING PLATE BY EQUIPMENT SUPPLIER CEILING MOUNTED EQUIPMENT BY OWNER BY EQUIP. SUPPLIER DETERMINED BY EQUIPMENT SUPPLIER VARIES VARIES VA R I E S VA R I E S VARIES VARIES SECTION B-B CO O R D I N A T E WI T H EQ U I P M E N T SU P P L I E R BY EQUIP. SUPPLIER DETERMINED BY EQUIPMENT SUPPLIER C EQUIPMENT L CONNECTION TO BE DESIGNED BY SUPPORT CONTRACTOR (TYP.) UNISTRUT WING FITTING STRUCTURAL STEEL BEAM (WHERE OCCURRING) SEE FRAMING PLAN UNISTRUT VERTICAL DROPS UNISTRUT ANGLE FITTING UNISTRUT CROSS TIE UNISTRUT DIAGONAL BRACING UNISTRUT WING FITTING UNISTRUT LOWER RAILS THREADED ROD DROPS FINISH CEILING (SEE RCP) STEEL INTERFACE PLATE BY EQUIPMENT SUPPLIER MOUNTING PLATE BY EQUIPMENT SUPPLIER SINGLE OR DOUBLE BOOM CEILING MOUNTED EQUIPMENT BY OWNER VARIES A B C TYP. ACP TO WALL APC/GWB TRANSITION TYP. GWB TO WALL WALL SURFACE WALL ANGLE WALL SURFACE WALL ANGLE GYPSUM BOARD SUSPENDED CEILING OR SOFFIT TAPE-ABLE EDGE BAND SUSPENDED ACOUSTIC PANEL CEILING SUSPENDED ACOUSTIC PANEL CEILING DRYWALL TRANSITION CLIP GWB D ALT. GWB TO WALL WALL SURFACE WALL ANGLE GYPSUM BOARD SUSPENDED CEILING OR SOFFIT ZIP STRIP EDGE TRIM CEILING HEIGHT EL: (VARIES - SEE RCP) 2 1/2" METAL STUD FRAMING AT 16" O.C. BRACED TO UNDERSIDE OF SLAB ABOVE. ALUMINUM ENCLOSURE BY NEWMAT 5/8" GWB ON DRYWALL SYSTEM 3/ 4 " BUILT IN PERIMETER CLIPS FOR STRECH MEMBRANE NEWMAT STRETCH MEMBRANE ALLOW PENETRATIONS IN ENCLOSURE TO HANG INTEGRATED LIGHTING AS REQUIRED, REF. ELECTRICAL Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " As indicated Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 1/25/2024 3:11:15 PM A211 1/26/2024 23289 CEILING DETAILS BO DC © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 3" = 1'-0"4B STEPPED CEILING DETAIL - ACT/DRYWALL 3" = 1'-0"4D DIAGONAL BRACING DETAIL AT SOFFITS 1 1/2" = 1'-0"2B OVERHEAD EQUIPMENT SUPPORT DETAIL - PLAN 1 1/2" = 1'-0"1D OVERHEAD EQUIPMENT SUPPORT DETAILS 3" = 1'-0"2D TYPICAL CEILING TRANSITION DETAILS 1/26/2024 CONSTRUCTION DOCUMENTS 3" = 1'-0"4C NEWMAT STRETCH MEMBRANE DETAIL 1/26/24 11/08/2024 EXTEND GYPSUM WALLBOARD FULL HEIGHT CEILING 3 5/8" METAL STUD 3 5/8" METAL STUDS @ 16" O.C. 3" SOUND ATTENUATION BLANKET 5/8" GYPSUM WALLBOARD EACH SIDE BASE AND FLOORING - SEE FINISH SCHEDULE SEE 2C/A600 FOR BASE CONDITION SEE 3C/A600 FOR HEAD CONDITION 1 HOUR RATED (UL DESIGN NO. U419) SOUND RATED PARTITION STC 43-45 1 AS SHOWN 4 7/8" 1LA 1LB AS SHOWN EXCEPT WITH 1/64" LEAD LINING UNDER ONE SIDE OF GWB TO 7' A.F.F. AS SHOWN EXCEPT WITH 1/32" LEAD LINING UNDER ONE SIDE OF GWB TO 7' A.F.F. REFER TO NOTE 2. SEE PARTITION TYPES FOR WALL CONSTRUCTION SCHEDULED BASE CONTINUOUS ACOUSTIC SEALANT, BOTH SIDES; FIRE-RESISTANT JOINT SYSTEM AT FIRE-RATED PARTITIONS3/ 8 " ( M I N . ) CONTINUOUS ACOUSTIC SEALANT, BOTH SIDES; FIRE-RESISTANT JOINT SYSTEM AT FIRE-RATED PARTITIONS COPE GYPSUM WALLBOARD AROUND METAL DECK PROFILE METAL EDGE TRIM WHERE EXPOSED TO VIEW STEEL RUNNER W/ MINIMUM 2" FLANGES; FASTEN TO METAL DECK PRIOR TO INSTALLATION OF SPRAY FIREPROOFING COPE GYPSUM WALLBOARD AROUND STEEL BEAM PROFILE (WHERE OCCURING) CONTINUOUS 20 GAUGE SHEET METAL FILLER; SET IN SEALANT AND FASTENED TO METAL DECK METAL DECK COMPRESSED SOUND ATTENUATION INSULATION AT NON-RATED PARTITIONS PARALLEL TO RIBS OF DECK PERPENDICULAR TO RIBS OF DECK NOTE: FASTEN STEEL RUNNER TO METAL DECK; FRICTION FIT METAL STUDS TO RUNNER AND FASTEN GYPSUM WALLBOARD TO STUDS (DO NOT FASTEN TO RUNNER); MAINTAIN GAP AS INDICATED BETWEEN METAL DECK AND METAL STUD / GYPSUM WALLBOARD TO ACCOMODATE DEFLECTION OF STRUCTURE 3/ 4 " 3/ 4 " 1/2" METAL STUDS - SEE PARTITION TYPE FOR SIZE 1 OR MORE LAYERS OF GYPSUM BOARD - REFER TO PARTITION TYPE FOR DETAILS 5/8" GAP 2 LAYERS OF 5/8" TYPE X GYPSUM BOARD, FASTEN TO STUD @ 24" O.C. W/ 1 5/8" TYPE S DRYWALL SCREWS CONTROL JOINT TRIM AS SPECIFIED 1. PARTITION TYPES ARE INDICATED ON FLOOR PLANS AS: 2. REFER TO FIRE SAFETY PLANS FOR LOCATIONS OF FIRE BARRIERS, FIRE WALLS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS. ALL FIRE AND / OR SMOKE RATED PARTITIONS, BARRIERS AND WALLS SHALL BE LABELED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILINGS OR ATTIC SPACES WITH PAINTED SIGNAGE 15 FEET FROM THE ENDS OF THE WALLS AND AT A SPACING NOT TO EXCEED 30 FEET BETWEEN END MARKINGS. 3. AT STUD PARTITIONS AND FURRED WALLS, PROVIDE MOISTURE RESISTANT G.W.B. AT ALL TOILET ROOMS, SHOWERS, CUSTODIAL CLOSETS, SOILED UTILITY ROOMS, HOUSEKEEPING CLOSETS, MECHANICAL EQUIPMENT ROOMS AND WITHIN 10 FT OF ANY PLUMBING FIXTURE LOCATION UNLESS OTHERWISE NOTED. (EXCEPT AT TILED WALL FINISHES WHERE NOTE #4 BELOW APPLIES) 4. AT STUD PARTITIONS AND FURRED WALLS, PROVIDE SUITABLE TILE BACKING BOARD (TYPE X @ RATED WALLS) OVER MINIMUM 0.0312" THICK METAL STUD FRAMING BEHIND CERAMIC, PORCELAIN AND STONE TILE WALL FINISH- REFER TO FINISH SCHEDULE. 5. MATERIALS AND CONSTRUCTION OF FIRE-RATED PARTITIONS, INCLUDING TAPING AND FINISHING OF GYPSUM BOARD FOR FULL HEIGHT, SHALL BE IN ACCORDANCE WITH DESIGNATED FIRE TEST AND MANUFACTURER'S DIRECTIONS TO ACHIEVE FIRE RESISTANCE RATING INDICATED. SEAL PERIMETERS AND ALL PENETRATIONS THROUGH FIRE-RATED PARTITIONS WITH SPECIFIED FIRE RESISTANT RATED MATERIALS. REFER TO THROUGH PENETRATION FIRESTOP SYSTEMS SCHEDULE FOR TYPICAL FIRERESISTIVE JOINT SYSTEMS. 6. ALL PARTITIONS SHALL BE SEALED AIRTIGHT FOR FULL HEIGHT INCLUDING PERIMETER & ALL PENETRATIONS. TAPE AT BOTH FACES & FINISH ALL GYPSUM BOARD JOINTS & FASTENERS. 7. SEE DOOR AND FRAME DETAILS, SHEET A601, FOR TYPICAL NOTES AND DETAILS ON FRAMING AND ANCHORING REQUIRMENTS. 8. PROVIDE CONTROL JOINTS IN ALL PARTITIONS: • 30'-0" O.C. MAX FOR GWB PARTITIONS PROVIDE RATED CONTROL JOINTS IN ALL RATED PARTITIONS. PARTITION NOTES 1 PARTITION TYPE 1. A 2-HR OR 3-HR F-RATING UL ASSEMBLY MAY BE USED PROVIDED THE CONCRETE FLOOR / WALL CONSTRUCTION COMPLIES WITH THE MINIMUM FLOOR / WALL THICKNESS AND MATERIAL REQUIREMENTS AS INDICATED IN THE UL ASSEMBLY. 2. A 3-HR F-RATING UL ASSEMBLY MAY BE USED PROVIDED THE CONCRETE FLOOR / WALL CONSTRUCTION COMPLIES WITH THE MINIMUM FLOOR / WALL THICKNESS AND MATERIAL REQUIREMENTS AS INDICATED IN THE UL ASSEMBLY. 3. FOR FLOOR PENETRATIONS LOCATED OUTSIDE WALL CAVITIES AND FLOOR PENETRATIONS LOCATED OUTSIDE FIRE-RESISTANCE-RATED SHAFT ENCLOSURES, PROVIDE THROUGH-PENETRATION FIRESTOP SYSTEM WITH A T-RATING OF NOT LESS THAN 1 HOUR OR NOT LESS THAN THE REQUIRED FIRE RESISTANCE RATING OF THE FLOOR PENETRATED, WHICHEVER IS GREATER. 4. A 2-HR OR 3-HR F-RATING UL ASSEMBLY MAY BE USED PROVIDED THE CONCRETE UNIT MASONRY IS UL CLASSIFIED AND THE MINIMUN WALL THICKNESS COMPLIES WITH THE REQUIREMENTS AS INDICATED IN THE ULASSEMBLY. 5. A 3-HR F-RATING UL ASSEMBLY MAY BE USED PROVIDED THE CONCRETE UNIT MASONRY IS UL CLASSIFIED AND THE MINIMUM WALL THICKNESS COMPLIES WITH THE REQUIREMENTS AS INDICATED IN THE UL ASSEMBLY. 6. JOBSITE CONDITIONS OF EACH THROUGH-PENETRATION FIRESTOP SYSTEM SHALL MEET ALL DETAILS OF THE UL-CLASSIFIED SYSTEM SELECTED. 7. IF JOBSITE CONDITIONS DO NOT MATCH THE SCHEDULED SYSTEMS, SUBMIT ALTERNATIVE SYSTEMS OR ENGINEERING JUDGEMENT DRAWINGS PREPARED BY THE FIRESTOPPING MANUFACTURER FOR THE ARCHITECT AND BUILDING OFFICIAL TO REVIEW AND APPROVE PRIOR TO INSTALLATION. 8. CONTRACTOR SHALL SELECT FROM UL-CLASSIFIED SYSTEMS AS LISTED IN THE SCHEDULE AND SELECT AN APPROPRIATE SYSTEM FOR EACH ASSEMBLY, OR SHALL PROVIDE ANOTHER THROUGH PENETRATION FIRESTOP SYSTEM TO BE REVIEWED AND APPROVED BY THE ARCHITECT AND THE BUILDING OFFICIAL WHICH PROVIDES EQUAL OR BETTER THROUGH PENETRATION PROTECTION AND IS SUPPORTED BY ACCEPTABLE TESTING AND DOCUMENTATION. 9. COORDINATE WORK WITH OTHER TRADES TO ASSURE THE PENETRATION OPENING SIZES AND LOCATION OF ITEMS WITHIN THE OPENING COMPLY WITH APPLICABALE REQUIREMENTS OF THE UL-CLASSIFIED SYSTEM SELECTED. FIRE STOPPING NOTES DEVICE TO BE ANCHORED MAY BE PLACED AT ANY POINT ON ANCHORAGE BETWEEN STUDS WIDTH AS REQUIRED BY STUD SPACING x14 GAUGE STEEL PLATE x LENGTH TO BE DETERMINED BY SIZE OF DEVICE TO BE MOUNTED TOP OF TRACK DEVICE TO BE ANCHORED - SIZE/CONFIGURATION VARIES - CONTRACTOR TO VERIFY IN FIELD PRIOR TO INSTALLATION WIDTH AS REQUIRED BY WALL TYPE - CONTRACTOR TO VERIFY IN FIELD PRIOR TO INSTALLATION BOTTOM TRACK GWB TYPICAL - SEE WALL TYPE SHEET 20 GAUGE MIN. "C" STUDS; FULL HEIGHT OF WALL DEVICE TO BE ANCHORED - CONTRACTOR TO FIELD VERIFY PRIOR TO INSTALLATION LOCATE ELECTRICAL OUTLET AND DATA OUTLETS ABOVE BACKING PLATE OR TO SIDE AS INDICATED ON INTERIOR ELEVATIONS - CONTRACTOR TO COORDINATE IN FIELD ALL LOCATIONS SHOWN OR NOT SHOWN ON INTERIOR ELEVATIONS. (2) - 20 GAUGE "C" - STUDS FROM FLOOR TO FINISH CEILING INSERT BETWEEN REG. WALL STUDS OR ADD ONE L. OR R. OF EXISTING ROOM WALL STUD LAYOUT TO OBTAIN DESIRED LOCATION OF CHANNEL #10 SHEET METAL SCREWS THRU 9/64" DIA. HOLES OR #28 DRILL AT 12" O.C. EA. SIDE FINISHED FLOOR MI N . M I N . MIN. PLAN ELEVATION VARIES - SEE WALL TYPE AS R E Q U I R E D - C O N T R A C T O R T O V E R I F Y I N F I E L D LC LC 4" 4" 4" NOTE: THICKNESS OF LEAD FOR BATTEN STRIPS/RIBBON AND DISKS/TABS SHALL BE THE SAME THICKNESS AS THE PARTITIONS IN WHICH THEY ARE INSTALLED. LEAD LINED G.W.B. ON SIDE OF RADIATION (U.O.N.). LEAD SHALL EXTEND TO A MIN. OF 7'-0" AFF. FINISH ALL JOINTS AND FASTENERS PER STANDARD G.W.B. CONSTRUCTION. 3" WIDE SHEET LEAD BATTEN STRIP/RIBBON BENT AT CORNERS. TACK IN PLACE BEFORE INSTALLING GWB. TYPICAL 2" WIDE SHEET LEAD BATTEN STRIP/RIBBON AT GWB JOINTS. TACK IN PLACE BEFORE INSTALLING GWB. TYPICAL INTERMEDIATE JOINT INSIDE CORNER JOINT OUTSIDE CORNER JOINT WALL DUCT EXTEND LEAD SHEET BEYOND TYPICAL RECEPTACLE BOX/PENETRATION TO A MIN. OF THE STUD THICKNESS AT ALL SIDES, AND WRAP LEAD SHEET AROUND BACKSIDE COMPLETELY. X RECEPTACLE BOX PIPE XX FASTENERS AT 8" O.C. MIN. AT EDGES AND 12" O.C. MIN. AT FIELD. PROVIDE LEAD DISKS/TABS OVER EVERY DRYWALL SCREW. TYPICAL EXISTING GLASS DOOR TO REMAIN WITH HARDWARE REMOVED AND IN PERMANTANTLY LOCKED POSITION BLACKOUT FILM BATT INSULATION 2 1/2" STUDS AS NEEDED GYPSUM BOARD DRILL THROUGH EXISTING FRAME HEAD TO ALLOW VENTING OF HEAT INTO PLENUM ABOVE NEW TYPE 1LA WALL CONSTRUCTION Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " As indicated Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 1/25/2024 3:11:17 PM A600 1/26/2024 23289 PARTITION TYPES BO DC © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1 1/2" = 1'-0"2C TYP BASE AT METAL STUD PARTITIONS 1 1/2" = 1'-0"3C TYPICAL HEADS AT METAL STUD PARTITIONS 1 1/2" = 1'-0"1C TYP CONTROL JOINT @ METAL STUD PARTITIONS 1" = 1'-0"3A BLOCKING FOR WALL MOUNTED DEVICES 1 1/2" = 1'-0"1D LEAD LINING DETAILS 1/26/2024 CONSTRUCTION DOCUMENTS 1 1/2" = 1'-0"3D EXISTING DOOR INFILL DETAIL 1/26/24 11/08/2024 WOOD AND HOLLOW METAL DOORS F N MA X . 3' - 7 " A F F 2 ' - 1 " 4" 6" LL 6"6" 10 " 1 ' - 0 " 10 " 1 ' - 0 " 6"6" B BI-FOLD BL BI-FOLD, FULL LOUVER PANELS BPL BI-FOLD, PANELED WITH HALF LOUVER D DUTCH DG DUTCH WITH HALF GLASS LITE DN DUTCH WITH NARROW LITE DV DUTCH WITH VISION LITE F FLUSH FG FULL GLASS G HALF GLASS GL HALF GLASS WITH LOUVER L LOUVERED (BOTTOM ONLY) LLLOUVERED (TOP & BOTTOM) LT LOUVERED (TOP ONLY) N NARROW LITE NL NARROW LITE WITH LOUVER P(#) PANELED (NUMBER OF PANELS) V VISION LITE VL VISION LITE WITH LOUVER NS NARROW STILE (ALUMINUM) NSRNARROW STILE (ALUINUM) WITH MIDDLE RAIL MS MEDIUM STILE (ALUMINUM) MSRMEDIUM STILE (ALUMINUM) WITH MIDDLE RAIL WS WIDE STILE (ALUMINUM) WSR WIDE STILE (ALUMINUM) WITH MIDDLE RAIL GA GLASS DOOR WITH CONTINUOUS BOTTOM RAIL & TOP PATCH HARDWARE GARGLASS DOOR WITH CONTINUOUS BOTTOM RAIL & TOP PATCH HARDWARE AND MIDDLE RAIL GE GLASS DOOR WITH TOP & BOTTOM LEADING EDGE PATCH HARDWARE GERGLASS DOOR WITH TOP & BOTTOM LEADING EDGE PATCH HARDWARE AND MIDDLE RAIL GP GLASS DOOR WITH TOP & BOTTOM PATCH HARDWARE GPRGLASS DOOR WITH TOP & BOTTOM PATCH HARDWARE AND MIDDLE RAIL GR GLASS DOOR WITH CONTINUOUS TOP & BOTTOM RAILS GRRGLASS DOOR WITH CONTINUOUS TOP & BOTTOM RAILS AND MIDDLE RAIL GS GLASS DOOR WITH CONTINUOUS STILES & RAILS DOOR TYPE DESIGNATIONS FRAME TYPE DESIGNATIONS A DOOR OPENING AF DOOR OPENING WITH FULL HEIGHT SIDELITE AS DOOR OPENING WITH SIDELITE AT DOOR OPENING WITH TRANSOM ATF DOOR OPENING WITH TRANSOM AND FULL HT. SIDELITE ATP DOOR OPENING WITH TRANSOM PANEL B BORROWED LITE BF FULL HEIGHT BORROWED LITE BT FULL HEIGHT BORROWED LITE BTF FULL HEIGHT BORROWED LITE WITH TRANSOM C CASED OPENING DA DOUBLE ACTING OR EMERGENCY EGRESS DE DOUBLE EGRESS NL1 DOOR TYPE SUB-LETTER (USED FOR VARIATIONS OF THE SAME TYPE) DOOR TYPE AS2A FRAME TYPE SUB-LETTER (USED FOR VARIATIONS OF THE SAME TYPE) FRAME TYPE NUMBER OF OPENINGS OR LITES DOOR / FRAME MATERIAL AL ALUMINUM GL GLASS HM HOLLOW METAL PL PLASTIC LAMINATE VENEER SS STAINLESS STEEL WD WOOD, WOOD VENEER GLASS MATERIAL CS COATED SPANDREL GLASS CV COATED VISION GLASS FG CLEAR FLOAT GLASS FR FIRE PROTECTION RATED GLASS FRW FIRE RATED GLASS/WALL IG INSULATED GLASS IT INSULATED TEMPERED SAFETY GLASS LL LEADED GLASS LS LAMINATED SAFETY GLASS MG TINTED AND / OR COATED FLOAT GLASS PG PATTERN GLASS TG TEMPERED GLASS WG WIRED GLASS GENERAL DOOR NOTES 1. ALL DOORS ARE 1 3/4" THICKNESS, UNLESS OTHERWISE NOTED. 2. ALL WOOD DOORS ARE SOLID CORE UNLESS OTHERWISE INDICATED EXCEPT ALL BI-FOLD AND POCKET DOORS ARE HOLLOW CORE UNLESS OTHERWISE INDICATED. 3. ALL INTERIOR GLASS IS 1/4" AND ALL INSULATED GLASS IS 1" UNLESS OTHERWISE INDICATED. 4. ALL EXTERIOR HOLLOW METAL DOORS ARE INSULATED. 5. REFER TO HARDWARE SCHEDULE ATTACHED TO DIVISION 8, SECTION "FINISH HARDWARE" FOR HARDWARE SET DESCRIPTIONS. 6. REFER TO TYPICAL PARTITION DETAILS, DRAWING A600 FOR FRAME THROAT REQUIREMENTS UNLESS OTHERWISE INDICATED ON DOOR SCHEDULE. 7. REFER TO DOOR AND FRAME TYPES, DRAWING A601 FOR FRAME PROFILES. 8. REFER TO DOOR DETAILS, DRAWING A601 FOR TYPICAL JAMB DETAILS. HEADS ARE SIMILAR TO JAMBS SHOWN UNLESS OTHERWISE INDICATED. 9. ALL DOORS TO HAVE STANDARD 5/16" UNDERCUT UNLESS OTHERWISE INDICATED OR REQUIRED TO RECIEVE SCHEDULED THRESHOLD. 10. 20, 45, 60, 90, ETC. INDICATES FIRE RATING IN MINUTES. 11. A PREFIX OF "E" MEANS EXISTING DOOR OR FRAME BEING REUSED. A PREFIX OF "R" MEANS AN EXISTING FRAME BEING RELOCATED. REMARKS NOTATION AUTOMATIC PUSH PLATE OPERATED AUTOMATIC DOOR DBL ACT DOUBLE ACTION SWING (NO STOPS AT FRAME) DBL EGRESS DOUBLE EGRESS FRAME AND DOOR LEAD LINED DOOR AND FRAME REQUIRE LEAD LINING; USE FULL HEIGHT STOPS AT FRAME MAG MAGNETIC HOLD OPEN POCKET POCKET DOOR W-STRIP WEATHERSTRIP / LIGHT SEAL NOTE A: NEW DOOR AND HARDWARE IN EXISTING FRAME. MODIFY AND REPAIR AS REQUIRED TO ACCOMODATE NEW HARDWARE. FIELD VERIFY FRAME OPENING SIZE. NOTE B: REFER TO DRAWING A____ (INSERT DRAWING NUMBER HERE) FOR ALUMINUM FRAME ELEVATIONS AND DETAIL REFERENCES. ALUMINUM DOOR MANUFACTURER SHALL VERIFY DOOR DIMENSIONS BASED UPON APPROVED SYSTEM STANDARDS. NOTE C: REFER TO INTERIOR ELEVATIONS FOR FRAME ELEVATIONS AND DIMENSIONS. NOTE D: NEW DOOR AND FRAME IN EXISTING WALL CONSTRUCTION. FIELD VERIFY FRAME THROAT SIZE REQUIRED. NOTE E: WIRE MESH DOOR AND FRAME. NOTE F: MODIFY EXISTING DOOR AND/OR FRAME AS REQUIRED TO ACCOMMODATE INSTALLATION OF NEW HARDWARE. NOTE G: NEW INSULATED OVERHEAD COILING DOOR AND STEEL CHANNEL FRAME. NOTE H: OVERHEAD COILING FIRE RATED COUNTER DOOR AND EXTRUDED ALUMINUM FRAME. NOTE I: OVERHEAD COILING COUNTER DOOR AND EXTRUDED ALUMINUM FRAME. NOTE J: SIDE COILING GRILLE AND STEEL FRAME. NOTE K: VISION PANEL AND PANIC DEVICE ON ACTIVE LEAF. AUTOMATIC FLUSH BOLTS AND NO VISION PANEL ON INACTIVE LEAF. NOTE L: FREEZER / COOLER DOOR, FRAME AND HARDWARE BY FREEZER / COOLER MANUFACTURER. NOTE M: FOUR SIDED FRAME. NOTE N: REFINISH EXISTING WOOD DOOR. REFER TO FINISH SCHEDULE FOR SURFACE PREPARATION AND FINISH SYSTEMS. REMOVE EXISTING HARDWARE SCHEDULED TO REMAIN PRIOR TO REFINISHING AND REINSTALL. NOTE O: REFER TO PLAN DETAIL FOR ADDITIONAL INFORMATION. NOTE P: REFER TO EXTERIOR ELEVATION AND WALL SECTION FOR ADDITIONAL DETAILS. DOOR / FRAME FINISHES PT PAINTED - MATCH EXISTING ST STAINED - MATCH EXISTING HARDWARE SETS HARWARE GROUP NO. 9 FOR USE ON ON DOOR 1614C QTY DESCRIPTION CATALOG NUMBER FINISH MFR 3 EA HINGE 3CB1 4.5 X 4.5 (HW AS REQ) 626 IVE 1 EA STOREFRONT LOCK ML2057 PSA ROSE/TRIM 626 COR (CORBIN) 1 EA CORE/CYLINDER AS DIRECTED BY OWNER 626 1 EA OVERHEAD STOP 104S US32D LCN 1 EA KICKPLATE 8400 16" X 34" B-CS US32D IVE 1 EA SILENCER SR64 GRY IVE FRAMES A SINGLE OR DOUBLE OPENING BORROWED LITES B1 SEE DOOR SCHEDULE ON SHEET A601 FOR DOOR OPENING SIZES AND HEAD / JAMB DETAIL DESIGNATIONS. REFER TO FRAME PROFILE DETAILS ON SHEET A601 FOR FRAME WIDTH DIMENSIONS. SE E S C H E D U L E SEE SCHED. 2" SEE SCHED. 2" SE E S C H E D . 3 ' - 2 " SEE DOOR SCHEDULE ON SHEET A601 FOR DOOR OPENING SIZES AND HEAD / JAMB DETAIL DESIGNATIONS. FRAME TYPE ELEVATIONS SHOW GLASS OPENING DIMENSIONS AND INTERMEDIATE MULLION WIDTHS ONLY; REFER TO FRAME PROFILE DETAILS ON SHEET A601 FOR FRAME WIDTH DIMENSIONS. 2" 2"2" 2" 2" JA M B D I M E N S I O N 7/8" MIN. 1/ 2 " 1/ 2 " DI M . V A R I E S TH R O A T SEE FLOOR PLAN FOR PARTITION TYPE 3/8" BACK-BEND RETURN H.M. DOOR FRAME SEE DOOR SCHEDULE FOR ADDITIONAL DETAIL REFERENCES DOOR OPENING WIDTH SEE SCHEDULE VA R I E S 1 1 5 / 1 6 " 2" 5/8" 1 1 5 / 1 6 " * JAMB AND HEAD CONDITION SIMILAR JAMB HEAD DOUBLE HEADER COPE AROUND STRUTS AT EACH END SEAL PERIMETER BOTH SIDES LEAD LINED H.M. DOOR FRAME. FULL WRAP AT OUTSWINGING DOOR (AS SHOWN) AND HALF WRAP AT INSWINGING DOORS. SEE PROFILE TYPE FOR DIMENSIONS. DBL JAMB STUDS LEAD LINED DOOR AND VISION GLASS IF OCCURS. SEE SCHED. FOR TYPE DOOR SILENCERS (WHERE REQ'D) CLOSED STUD JAMB ANCHORS LEAD LINED GWB ON SIDE OF RADIATION DOOR WIDTH SEE SCHEDULE BACKBEND RETURN LEAD LINED GWB ON SIDE OF RADIATION SEE FLOOR PLAN FOR PARTITION TYPE AND THICKNESS NOTES: 1. THICKNESS OF LEAD FOR DOOR AND H.M. FRAME SHALL BE THE SAME THICKNESS AS THE PARTITIONS IN WHICH THEY ARE INSTALLED. 2. LEAD LINED H.M. DOOR FRAME TO HAVE ADDITIONAL REINFORCING TO CARRY WEIGHT OF DOOR AND INSTALLED PRIOR TO PLACING LEAD LINING. LEAD SHEET SHALL BE UNIFORM AND PERMANENTLY ATTACHED. 3. LEAD LINED H.M. DOOR FRAME TO BE FACTORY PRIMED AND PAINTED. 4. DOOR HARDWARE REQ'D: LEAD LINED LOCKSET/LATCH, HEAVY DUTY HINGES OR PIVOT HINGES FOR LEAD LINED DOORS, IF OCCURS LEAD LINED ASTRAGAL, AND IF OCCURS LEAD LINED CLOSER COVER. 2" 1 1/2" DI M . V A R I E S TH R O A T LEAD LINED GWB ON SIDE OF RADIATION LEAD LINED H.M. BORROWED LITE FRAME; HALF WRAP FRAME ON SIDE OF RADIATION. SEE PROFILE TYPE FOR DIMENSIONS CLOSED STUD JAMB ANCHORS LEAD VISION GLASS. SEE SCHED. FOR TYPE REMOVABLE STOP DOUBLE STUDS AT JAMB BORROWED LITE DIMENSION SEE DOOR SCHEDULE JAMB VA R I E S NOTES: 1. THICKNESS OF LEAD FOR GLASS AND H.M. FRAME SHALL BE THE SAME THICKNESS AS THE PARTITIONS IN WHICH THEY ARE INSTALLED. 2. LEAD SHEET SHALL BE UNIFORM AND PERMANENTLY ATTACHED. 3. LEAD LINED H.M. BORROWED LITE FRAME TO BE FACTORY PRIMED AND PAINTED. 4. LEAD GLASS (STANDARD UP TO 48"X96") TO BE OF HIGH QUALITY, OPTICAL-GRADE, LEAD BARIUM GLASS CONTAINING MIN. LEAD OXIDE CONTENT OF 55%. 5. LEADED ACRYLIC (STANDARD UP TO 72"X96") TO BE OF SHATTER-RESISTANT, DISTORTION-FREE OPTICAL CLARITY LEAD ACRYLIC GLASS CONTAINING MIN. 30% LEAD BY WEIGHT. BACKBEND RETURN Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " As indicated Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 8/21/2024 11:58:36 AM A601 3/1/2024 23289 DOOR SCHEDULE, DOOR AND FRAME TYPES BO DC © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . DOOR & FRAME SCHEDULE NUMBER ROOM NAME DOOR FRAME REMARKS REVISIONTYPE WIDTH PANEL WIDTH A PANEL WIDTH B HEIGHT THICKNESS MATERIAL FINISH GLAZING FIRE RATING HARDWARE TYPE MATERIAL FINISH HEAD JAMB 1612 N.M. TECH N 3'-0" 3'-0" 7'-0" 1 3/4" WD ST TG 1 A HM PT 2D/A601 2D/A601 CARD READER 1613 CONTRAST MEDIA PREP AREA F 3'-0" 3'-0" 7'-0" 1 3/4" WD ST 2 A HM PT 3D/A601 3D/A601 1/32" LEAD LINING, CARD READER 1614C UTILITY CLOSET LL 5'-6" 3'-6" 2'-0" 7'-0" 2" WD ST 9 A HM PT 3D/A601 3D/A601 2 1622A N.M./CT IMAGING F 3'-0" 3'-0" 7'-0" 1 3/4" WD ST 3 A HM PT 3D/A601 3D/A601 1/64" LEAD LINING 1622B N.M./CT IMAGING F 5'-0" 4'-0" 1'-0" 7'-0" 1 3/4" WD ST 20 MIN 4 A HM PT 3D/A601 3D/A601 MATCH EXISTING DOOR AND HARDWARE BUT NEW DOOR TO HAVE 1/32" LEAD LINING, EXISTING CARD READER TO REMAIN BORROWED LITE SCHEDULE NUMBER ROOM NAME LITE FRAME REMARKS REVISIONTYPE WIDTH HEIGHT GLAZING FIRE RATING TYPE MATERIAL FINISH HEAD JAMB SILL 1622C N.M./CT IMAGING B1 7'-0" 4'-0" LL B1 HM PT 4D/A601 4D/1601 4D/A601 1/64" LEAD LINING 1/26/2024 CONSTRUCTION DOCUMENTS 1 5/8/2024 NM RFI 1 2 8/21/2024 NM RFI 4 3" = 1'-0"2D DOUBLE RABETTED H.M. FRAME PROFILE @ DRYWALL PARTITIONS 3" = 1'-0"3D LEAD LINED - H.M DOOR FRAME DETAILS 3" = 1'-0"4D LEAD LINED BORROWED LITE DETAILS - H.M. FRAME (SIDELITE SIMILAR) 1 1 1 2 11/08/2024 INTERIOR ELEVATION GRAPHIC LEGEND PAPER TOWEL DISPENSER SOAP DISPENSER BIOHAZARD WASTE NEEDLE RECEPTACLE HAND SANITIZER DISPENSER CLOCK INTERIOR ELEVATION GENERAL NOTES 1. REFER TO FINISH PLANS FOR MORE INFORMATION. 4'-0" 7' - 0 " 1'-0" 7'-0" 4'-6" 1'-4" LINEN STORAGEIV POLE SOILED LINEN CART WASTE BIN PAPER TOWEL DISPENSER SOAP DISPENSER 2C A800 PLAM FASCIA ABOVE 4' - 0 " 3 ' - 2 " 4" BASE RE: FINISH SCHEDULE 2' - 1 0 " 2' - 1 0 " 1'-0"7'-0"4'-6" MED GAS ALARM PANEL (MGAP) FLUSH MOUNTED IN WALL VERTICAL DUCT. PAINT COVER TO MATCH WALL 1622C 3' - 2 " 4 ' - 0 " EQ. BY VENDOR MIN. 6" 4" BASE RE: FINISH SCHEDULE 1A A800 TYP. X-RAY IN USE LIGHT 8'-0" SURFACE MOUNTED HORIZONTAL DUCT 8" 2 ' - 0 " 2 ' - 0 " 2 ' - 1 0 " 2'-0" 2'-0" 2'-0" 4" P.LAM FASCIA 1C A800 TYP. 1A A800 TYP. PAPER TOWEL DISPENSER SOAP DISPENSER 4" BASE RE: FINISH SCHEDULE EQ. BY VENDOR 1'-3" MIN. 2' - 1 0 " 7'-0" 6' - 1 0 " REUSE CABINETS FROM EXISTING HOT LAB, VERIFY DIMENSIONS AND ADJUST FILLER PANEL SIZING AS NECESSARY 1'-7 1/4" 3'-0" 3'-0" V.I.F. 7'-7 1/4" FILLER PANELS P.LAM FASCIA REUSE EXISTING RADIOACTIVE WASTE BIN 8" 2 ' - 6 " 2 ' - 0 " 3 ' - 0 " RELOCATED EXISTING STAINLESS STEEL COUNTERTOP AND SUPPORTS, MODIFY AS NEEDED 4" BASE RE: FINSIH SCHEDULE EQ EQ EQ PHONE WALL CLOCK TYPICAL DEVICE ARRANGEMENT AT TYPICAL ROOM DOOR TYP. ELECTRICAL/DATA OUTLETS TV JACK, CABLE OUTLET MONITOR OUTLET, CLOCK OUTLET ELECTRICAL SWITCH, NURSE CALL, CANCEL SWITCH, FIRE ALARM CONTROLPUSH PLATE, THERMOSTAT/ HUMIDSTAT (ADJUSTABLE TYPE) THERMOSTAT/ HUMIDSTAT (SENSING TYPE) EMERGENCY CALL BUTTON WITH PULL CORD FE FEC FIRE ALARM SIGNAL AND PULL STATION - ALIGN UNITS ELECTRICAL COMMUNICATIONS PANELBOARD LIGHT SWITCH(ES) DOOR FRAME THERMOSTAT (SENSING TYPE ONLY) THERMOSTAT (ADJUSTABLE) F SURFACE MOUNTED PAPER TOWEL DISPENSER SOAP DISPENSER ELECTRICAL 3' - 8 " 4' - 0 " A T W A L L S OV E R CO U N T E R S 7' - 8 " 3" U. O . N . 4' - 8 " 3' - 8 " 7' - 0 " @ SH O W E R 4' - 8 " TO T O P O F FI R E C A B I N E T 4' - 0 " BO T . O F LE N S 6' - 8 " 3' - 0 " U. O . N . 3' - 8 " U. O . N . 3' - 2 " 7' - 0 " 4' - 0 " 3' - 1 0 " 3' - 1 0 " 3" CARD READER AT DOOR, LATCH SIDE CL 3' - 1 0 " 10 " CL CL 4" AL I G N B . O . F E C F L A N G E W/ T . O . W A L L B A S E COMBINATION FIRE EXTINGUISHER/BLANKET CABINET TO T O P O F C A B I N E T 4' - 8 " M A X . 1' - 0 " . CL CONTRACTOR NOTE: WHERE WALL MOUNTED ELECTRICAL/AV/IT/SECURITY/LIFE SAFETY DEVICES ARE LOCATED AT DIFFERENT ELEVATIONS, BUT IN CLOSE PROXIMITY TO ONE ANOTHER, ALIGN THESE DEVICES VERTICALLY ABOUT THEIR CENTERLINE WHERE POSSIBLE - REVIEW WITH ARCHITECT AS NEEDED PRIOR TO FINAL ROUGH-IN - SEE EXAMPLE BELOW EXAMPLE - TYPICAL VERTICAL DEVICE ARRANGEMENT ON WALL CLOCK FIRE ALARM THERMOSTAT - SENSOR ONLY SWITCHES PHONE C HE I G H T CO U N T E R 8" L 1' - 6 " Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " As indicated Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 1/25/2024 3:11:21 PM A701 1/26/2024 23289 INTERIOR ELEVATIONS BO DC © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/2" = 1'-0"1A NM/CT NORTH ELEVATION 1/2" = 1'-0"1C NM TECH SOUTH ELEVATION 1/2" = 1'-0"3A NM TECH WEST ELEVATION 1/2" = 1'-0"3C CONTRAST MEDIA PREP AREA EAST ELEVATION 1/26/2024 CONSTRUCTION DOCUMENTS 1/4" = 1'-0"1D TYPICAL MOUNTING HEIGHTS 1/26/24 11/08/2024 SE E EL E V A T I O N S FACE OF FINISHED WALL FINISHED CEILING 1 x 3 WD LEDGER 3/4" P. LAM. DOOR WITH PVC EDGING * 3/4" ADJ. P. LAM. SHELF WITH PVC EDGING * UNDER CABINET LIGHT (WHERE OCCURRING) VA R I E S 1/ 2 " 1/ 2 " NOTES: 1. SEE REFLECTED CEILING PLANS FOR CEILING/SOFFIT CONDITIONS 2. SEE INTERIOR ELEVATIONS FOR FASCIA CONFIGURATIONS 3/4" P. LAM. PANEL TOP AND BOTTOM WITH PVC EDGE * 1" 2' - 6 " 1'-3" P.LAM FASCIA DI M E N S I O N V A R I E S ; S E E E L E V A T I O N S FACE OF FINISHED WALL SOLID SURFACE (SS1) OVER 3/4" PARTICLE BOARD WOOD BLOCKING IN WALL ALUMINUM SUPPORT BRACKET BEYOND (SPANS EXCEEDING 5'-0") GROMMET; AS REQUIRED 1 1 / 2 " B-1 VARIES; SEE PLANS 3" 4" 3/4" 3/ 4 " 1 5 / 8 " 2'-0" 7' - 0 " SECURE UNIT(S) TO CONCEALED BLOCKING AT WALL WITH FINISH OVAL HEAD SCREWS AND FINISH OVAL CUP WASHERS FINISHED CEILING FACE OF FINISHED WALL 1x3 WOOD LEDGER STRIP - LOCATED ON CENTER (4) 3/4" P.LAM. ADJ. SHELF WITH PVC EDGING 1" P.LAM. DOOR WITH PVC EDGING 3/4" P.LAM. PANEL WITH PVC EDGE P.LAM BASE NOTES: 1. SEE REFLECTED CEILING PLANS FOR CEILING/ SOFFIT CONDITIONS 2. SEE INTERIOR ELEVATIONS FOR FASCIA CONFIGURATIONS 3/4" P.LAM. P.PLAM EDGE P.LAM FASCIA Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 1 1/2" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 1/25/2024 3:11:22 PM A800 1/26/2024 23289 INTERIOR DETAILS BO DC © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1 1/2" = 1'-0"1C WALL CABINET - P. LAM FASCIA 1 1/2" = 1'-0"1A OPEN COUNTER - SOLID SURFACE 1 1/2" = 1'-0"2C TALL EQUIPMENT/LINEN CABINET - P. LAM FASCIA 1/26/2024 CONSTRUCTION DOCUMENTS 1/26/24 11/08/2024 A701 1A A7013A 1C A701 3C MED (EXISTING) X60 ADMIN ASSISTANT (EXISTING) X70 DIRECTOR OF MARKETING (EXISTING) X72 STORAGE (EXISTING) 1809 GENERAL COUNSELOR (EXISTING) X74 CHECK-IN/ WAITING (EXISTING) 1601 TECH/WORK (EXISTING) 1602 LOCKERS (EXISTING) 1610 PATIENT TOILET (EXISTING) 1625 DIAGNOSTICS (EXISTING) 1603 DIRECTOR (EXISTING) 1609 STRESS TEST (EXISTING) 1611 N.M. WAITING (EXISTING) 1614 IDF 2008 ELECTRICAL 2006 OFFICE 2010 OFFICE (EXISTING) 119 CORRIDOR (EXISTING) 2004 CLOSET 2009 MAIL (EXISTING) 2061 TOILET 2446 N.M .TECH 1612 CONTRAST MEDIA PREP AREA 1613 N.M. / CT IMAGING 1622 WELL AND PROBE MACHINE LINEN STORAGE INJECTION CHAIR POSITIONING POINT IV STAND SOILED LINENS BARIATRIC CHAIR BED TABLE LOCKERS CONTRAST INJECTOR HEAD P2 PAINT: P1/P3 BASE: B1 FLOORING: F1 PAINT: P1 BASE: B1 FLOORING: F1 PAINT: P1/P2 BASE: B1 FLOORING: F1 GE PROVIDED NM/CT MACHINE COLLIMATOR CARTSECG MONITOR PIDB AND MDP UPS POWER DISTRIBUTION UNIT SMART CONSOLE XELERIS WORKSTATION SERVER P3 ELECTICAL RISERS ELECTICAL RISER CONTRAST INJECTOR CONTROLS ELECTRICAL RISER Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 1/4" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/AVH Nuc-Med CT.rvt 1/25/2024 3:11:23 PM A900 1/26/2024 23289 FINISH AND EQUIPMENT PLAN BO DC © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/4" = 1'-0"1C Nuc-Med CT Rooms - Finish and Equipment Plan 1/26/2024 CONSTRUCTION DOCUMENTS 1622 IV STAND OFOI N N N MOBILE 1622 SOILED LINENS CART OFOI N N N MOBILE 1622 BARIATRIC CHAIR OFOI N N N FIXED EXISTING 1622 BED TABLE OFOI N N N MOBILE EXISTING 1622 ECG MONITOR OFCI Y Y N MOBILE GE PROVIDED 1622 CONTRAST INJECTOR OFCI Y Y N FIXED CEILING MOUNTED 1622 COLLIMATOR CARTS (X2) OFVI N N N MOBILE GE PROVIDED 1622 TRANSFORMER FOR 6KVA UPS OFCI Y N N FIXED GE PROVIDED 1622 6 KVA UPS OFCI Y N N FIXED GE PROVIDED 1622 PARTIAL UPS OFCI Y N N FIXED GE PROVIDED 1622 MDP (MAIN DISCONECT PANEL) CFCI N FIXED PER ELECTRICAL DRAWINGS 1622 PIDB (POWER INPUT DISTRIBUTION BOX) CFCI N FIXED PER ELECTRICAL DRAWINGS 1622 NM/CT MACHINE OFVI Y Y N FIXED GE PROVIDED 1612 SERVER OFVI Y Y N FIXED GE PROVIDED 1612 XELERIS WORKSTATION OFVI Y Y N FIXED GE PROVIDED 1612 SMART CONSOLE OFVI Y Y N FIXED GE PROVIDED 1612 INJECTION CHAIR OFOI N N N MOBILE 1612 WELL AND PROBE MACHINE OFOI Y Y N MOBILE EXISTING ROOM EQUIPMENT FURNISH/INSTALL POWER DATA PLUMBING FIXED/MOBILE NOTES EQUIPMENT SCHEDULE SS1 SOLID SURFACE CORIAN CAMEO WHITE COUNTERTOPS PLAM1 PLASTIC LAMINATE WILSONART FUSION MAPLE, 7909K-78 (335) CABINETRY MILLWORK/CASEWORK PBG PAINTED GYPSUM BOARD CEILING SHERWIN WILLIAMS MANUFCATURER STANDARD WHITE, FLAT FINISH SOFFITS ACT 24" X 24" CEILING TILE ARMSTORNG OPTIMA 574, WHITE THROUGHOUT CEILING F1 HOMOGENOUS SHEET VINYL, HEAT WELDED WITH COLOR MATCHING RODS TARKETT MELODIA 3.0 ANNAPOLIS 0970 THROUGHOUT FLOORING B1 4" RESILIANT BASE TARKETT MOON ROCK 29 THROUGHOUT BASE P3 ACCENT WALL PAINT SHERWIN WILLIAMS SW7603, POOLHOUSE, EGG SHELL FINISH ACCENT WALL P2 ACCENT WALL PAINT SHERWIN WILLIAMS SW9026, TARNISHED TRUMPET, EGG SHELL FINISH ACCENT WALL P1 PRIMARY WALL PAINT SHERWIN WILLIAMS SW6126, NAVAJO WHITE, EGG SHELL FINISH WALLS PAINT FINISH TYPE ID DESCRIPTION MANUFACTURER COLOR/PATTERN TYPICAL LOCATION FINISH SCHEDULE OFOI = OWNER FURNISHED / OWNER INSTALLED OFVI = OWNER FURNISHED / VENDOR INSTALLED CFCI = CONTRACTOR FURNISHED / CONTRACTOR INSTALLED OFCI = OWNER FURNISHED / CONTRACT INSTALLED 1/26/24 11/08/2024 CONTRACTOR REQUIREMENTS FOR THE DEMOLITION OF, OR ADDITION TO, ANY PORTION OF AIR, PLUMBING OR HYDRONIC SYSTEMS. COVER SHEET NOTES: THE FOLLOWING SHALL APPLY TO ALL MECHANICAL SYSTEMS AFFECTED BY CONSTRUCTION ACTIVITIES. SYSTEMS INCLUDED BUT ARE NOT LIMITED TO HVAC, EXHAUST, EQUIPMENT, DUCTWORK, DUCTWORK ACCESSORIES, HYDRONICS, COILS, FILTERS, PLUMBING, TEMPERATURE CONTROLS, LIFE SAFETY CONTROLS AND PRESSURIZATION CONTROLS. 1. AIR QUALITY, QUANTITY AND PRESSURE RELATIONSHIPS SHALL COMPLY WITH THE LATEST, ANSI/ASHRAE/ASHE STANDARD 170 REQUIREMENTS. 2. COMPLY WITH THE FACILITY'S INFECTIOUS CONTROL RISK ASSESSMENT (ICRA) REQUIREMENTS. 3. MAINTAIN EXISTING AIR QUALITY REQUIREMENTS, AIR PRESSURIZATION AND OTHER UTILITY REQUIREMENTS FOR OCCUPIED AREAS DURING ANY RENOVATION OR CONSTRUCTION. 4. DETERMINE AND VERIFY THE AREAS SERVED BY THE AFFECTED SYSTEMS. 5. TAKE AIR AND OR/ WATER BALANCE READINGS OF THE SYSTEMS BEING AFFECTED. 6. IF THERE ARE SPACES BEING SERVED OUTSIDE OF THE DEMOLITION OR ADDITION AREA, THE FOLLOWING PROCEDURES MUST BE TAKEN: a. TAKE AIR AND/OR WATER BALANCE READINGS AS NEEDED TO QUANTIFY THE AIR AND/OR WATER FLOWS DELIVERED TO THE SYSTEMS OUTSIDE THE AFFECTED AREA. b. DURING DEMOLITION, TAKE ALL NECESSARY MEASURES TO MAINTAIN THE CORRECT AIR AND/OR WATER FLOWS TO THE SYSTEMS THAT ARE REMAINING. c. AFTER THE COMPLETION OF DEMOLITION, VERIFY THAT AIR AND/OR WATER FLOWS ARE CORRECT. d. AFTER COMPLETING ANY ADDITIONS TO THE SYSTEM, VERIFY THAT AIR AND/OR WATER FLOWS ARE CORRECT. 7. THE CONTRACTOR IS TO PROVIDE TEMPORARY AIR/AND OR WATER SYSTEMS AS NEEDED TO MAINTAIN PROPER TEMPERATURE AND PRESSURE RELATIONSHIPS OF SPACES REQUIRED TO BE OCCUPIED DURING CONSTRUCTION. 8. ALL TEMPORARY AIR SUPPLY SYSTEMS MUST UTILIZE FINAL FILTERS THAT ARE A MINIMUM OF 90% EFFICIENT (MERV 14). FINAL FILTERS MUST BE DOWNSTREAM OF ALL AIR SUPPLY COMPONENTS. MECHANICAL GENERAL NOTES: A. THESE NOTES APPLY TO ALL SHEETS CONTAINING HVAC, PIPING, PLUMBING, MEDICAL GAS, TEMPERATURE CONTROLS, AND FIRE PROTECTION WORK. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. WHERE A DISCREPANCY EXISTS BETWEEN THESE PLANS AND THE PROJECT SPECIFICATIONS, THE SPECIFICATION REQUIREMENTS SHALL TAKE PRECEDENCE OVER THE DRAWINGS. B. VERIFY THE EXISTING CONDITIONS AT THE PROJECT SITE BEFORE SUBMITTING COST PROPOSAL. BE ADVISED THAT LOCATIONS SHOWN ARE APPROXIMATE. AN ATTEMPT HAS BEEN MADE TO SHOW ALL PIPING, FIXTURES, DUCTWORK, AND OUTLETS. CONTRACTOR SHALL VISIT THE SITE TO VERIFY COMPONENTS, LOCATIONS AND SIZES SHOWN OR NOT SHOWN. ALL COMPONENTS NEED TO BE REMOVED IN THE DEMOLITION AREA UNLESS NOTED ON THE DRAWINGS. IF DEVIATION BETWEEN EXISTING CONDITIONS AND NEW WORK IS FOUND, CONTRACTOR SHALL NOTIFY ENGINEER. C. IT IS MANDATORY THAT THE EXISTING BUILDING REMAIN IN CONTINUOUS AND NON-INTERRUPTED OPERATION DURING THE CONSTRUCTION OF THE ADDITIONS AND REMODELING/ALTERATION OF THE EXISTING BUILDING. SERVICES TO THE EXISTING BUILDING SHALL BE KEPT ON CONTINUOUS OPERATION EXCEPT DURING SCHEDULED SHUTDOWNS FOR EXTENSION OR MODIFICATION. PLAN TO COMPLETE SHUTDOWNS DURING OFF HOURS TO MINIMIZE IMPACT TO THE OWNER. COORDINATE SHUTDOWNS WITH THE OWNER A MINIMUM OF 14 DAYS PRIOR TO WORK. PROVIDE TEMPORARY SERVICES WHERE NECESSARY TO ACCOMPLISH ANY SHUTDOWN. THIS INCLUDES BUT IS NOT LIMITED TO STAFFING AND EQUIPMENT FOR FIRE WATCHES, PROVISIONS FOR BOTTLED WATER, AND TEMPORARY HEATING OR COOLING EQUIPMENT. TEMPORARY MEASURES SHALL NOT BE REMOVED UNTIL THE PERMANENT SYSTEMS ARE OPERATIONAL AND HAVE PASSED ALL REQUIRED TESTING. D. REFER TO THE SPECIFICATIONS AND ARCHITECTURAL PLANS FOR PHASING REQUIREMENTS. DURING EACH PHASE THE CONTRACTOR SHALL COMPLETE ALL WORK LOCATED WITHIN THE BOUNDARY OF THAT PHASE. ANY WORK AND THAT MUST BE COMPLETED IN THE AREA AFTER THAT AREA HAS BEEN TURNED OVER TO THE OWNER SHALL BE IDENTIFIED AT THE BEGINNING OF THE PHASE FOR EVALUATION AND ACCEPTANCE OF THE OWNER. E. CONTRACTOR SHALL BE RESPONSIBLE FOR THEIR OWN DEMOLITION, REMOVAL, CAPPING, STORING, ABANDONING, DISCONNECTING, RELOCATING AND RECONNECTION OF EXISTING EQUIPMENT AND MATERIAL. ALL CUTTING, PATCHING, REPAIRING, REPLACEMENT AND REFINISHING SHALL MATCH THE EXISTING CONSTRUCTION AS NEARLY AS POSSIBLE. F. EXCEPT WHERE OTHERWISE SHOWN OR NOTED ON THE DRAWINGS AS "TO BE RETAINED, RELOCATED", ALL EXISTING EQUIPMENT AND MATERIAL IN AREAS TO BE REMODELED/ALTERED SHALL BE REMOVED WHERE THEY INTERFERE WITH PROPOSED NEW CONSTRUCTION AND/OR WITH PROPOSED USAGE OF SPACE BY OWNER AS FOLLOWS: a. REMOVE ANY PIPING PROTRUDING ABOVE FINISHED FLOOR OR THROUGH WALL AND CAP WITHIN 3 PIPE DIAMETERS OF NEAREST ACTIVE MAIN WITH MATERIAL TO MATCH EXISTING. b. REMOVE ALL FIXTURES, CARRIERS, SUPPLY AND WASTE AND VENT PIPING, STEAM, HEATING HOT WATER, HVAC SUPPLY, RETURN AND EXHAUST AS NOTED. CAP WITHIN 3 PIPE DIAMETERS OF NEAREST ACTIVE MAIN. SUPPLY AND RETURN MAINS ON PIPING SYSTEMS CONVEYING WATER OR GASES SHALL BE VALVED AND CAPPED c. IN REMODELED/ALTERED AREAS, ANY PIPING OR DUCTWORK PASSING THROUGH THE REMODELED AREAS TO SERVE (OR BEING SERVED FROM EXISTING ADJACENT, REMOTE, OR SURROUNDING AREAS THAT ARE TO REMAIN) SHALL BE RETAINED AND KEPT OPERATIONAL AND SHALL BE REROUTED IN ALL CASES WHERE THEY INTERFERE WITH ANY NEW WORK OR USAGE TO BE ACCOMPLISHED IN THE REMODELED AREA. d. REMOVE UNUSED OR ABANDONED HANGERS AND PATCH ABANDONED PENETRATIONS TO MATCH EXISTING. e. PENETRATIONS THROUGH EXISTING WALLS AND FLOORS FORMERLY OCCUPIED BY REMOVED PIPING OR DUCTWORK SHALL BE PATCHED TO MATCH EXISTING CONSTRUCTION. f. RE-SUPPORT ANY PIPING AND DUCTWORK THAT WAS SUPPORTED FROM BUILDING ELEMENTS REMOVED AS PART OF THE WORK. g. MAINTAIN CONTROL WIRING OR PNEUMATIC TUBING REQUIRED FOR THE CONTINUED PROPER OPERATION OF THE BUILDING AUTOMATION SYSTEM. G. ALL EXISTING EQUIPMENT BEING REMOVED WILL BE HANDED OVER TO OWNER FOR FIRST RIGHT OF SALVAGE. IF OWNER REFUSES SALVAGE ITEMS,REMOVING CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSAL. H. CONTRACTOR SHALL REFER TO THE DRAWINGS OF ALL TRADES TO FAMILIARIZE THEMSELVES WITH EXTENT OF WORK INCLUDING BUT NOT LIMITED TO WHERE NEW PARTITIONING IS BEING INSTALLED, WHERE EXISTING PARTITIONING IS BEING REMOVED, WHERE CEILINGS ARE BEING REMOVED AND/OR REPLACED, ETC. I. THESE DRAWINGS ARE NECESSARILY DIAGRAMMATIC IN NATURE. NOT ALL FITTINGS, OFFSETS, VENTS OR DRAINS ARE SHOWN. THE CONTRACTOR SHALL INCLUDE ALL FITTINGS, OFFSETS, VENTS, DRAINS, AND DEVICES REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. J. PERFORM AIR AND FLUID BALANCE PRE-TEST ON ALL DISTRIBUTION EQUIPMENT AND ALL AIR OUTLETS IN THE AREA PRIOR TO COMMENCING WORK. SUBMIT PRE-TEST INFORMATION TO OWNER/ENGINEER. K. PROVIDE ACCESS DOORS IN DUCTWORK AND/OR ARCHITECTURAL ELEMENTS WHERE REQUIRED TO ACCESS ALL EQUIPMENT REQUIRING MAINTENANCE AND ADJUSTMENT. THIS EQUIPMENT INCLUDES BUT IS NOT LIMITED TO SENSORS, DAMPERS, ACTUATORS, CONTROL DEVICES, VALVES, ETC. ACCESS DOORS SHALL BE SIZED TO PROVIDE APPROPRIATE ACCESS BASED ON HEIGHT OF ACCESS REQUIRED AND ACTIVITY. INSTALL SUCH THAT ACCESS DOOR IS FULLY OPERABLE WITHOUT THE REMOVAL OF ARCHITECTURAL ELEMENTS SUCH AS CEILING RUNNERS, SUPPORTS, ETC. INSTALL IN A LOCATION SUCH THAT STEPPING OR LEANING OVER PERMANENT EQUIPMENT OR FURNITURE IS NOT REQUIRED. WHERE ACCESS DOORS ARE REQUIRED IN ARCHITECTURAL ELEMENTS THAT PROVIDE A FIRE AND/OR SMOKE RATING, ACCESS DOOR SHALL MAINTAIN THE REQUIRED RATING. L. SEAL ALL WALL PENETRATIONS (DUCTWORK, PIPING, CONTROLS, CONDUITS, ETC.) WITH NON-COMBUSTIBLE MATERIAL. SEAL PENETRATIONS INTO ROOMS THAT REQUIRE PRESSURE CONTROL OR SOUND ISOLATION. WITH NON-COMBUSTIBLE MATERIAL AND CAULK. M. PIPING AND DUCTWORK SHALL NOT BE ROUTED OVER ELECTRICAL AND TELECOM ROOMS. WHERE ROUTING OVER SUCH ROOMS IS UNAVOIDABLE, CONTRACTOR SHALL COORDINATE WITH OWNER, DESIGN TEAM, AHJ, AND OTHER TRADES REGARDING LOCATION OF PANELS AND UTILITY ROUTING AND SHALL PROVIDE DRIP PANS UNDER ALL UTILITIES WITH MOISTURE SENSORS OR DRAIN PIPING AS REQUIRED BY THE SPECIFICATIONS. N. REMOVAL AND REINSTALLATION OF CEILINGS REQUIRED FOR THE COMPLETION OF WORK IS THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL REPAIR OR REPLACE ALL DAMAGED CEILING COMPONENTS TO MATCH EXISTING. WHERE AN IDENTICAL MATCH IS NO LONGER AVAILABLE, CONTRACTOR SHALL PROVIDE A SIMILAR REPLACEMENT UPON APPROVAL FROM THE OWNER. O. FLEXIBLE DUCTWORK SHALL HAVE A MAXIMUM LENGTH OF 48" REGARDLESS OF LENGTH SHOWN ON DRAWINGS. FLEX DUCT INSTALLATION SHALL BE AT TERMINAL ENDS ONLY. CONNECTIONS AT VAV BOX INLETS SHALL BE SOLID HARD DUCT. THE DUCTWORK AT ANY FIRE AND/OR FIRE SMOKE DAMPER SHALL BE HARD DUCT. P. LOCATE PIPING AND DUCTWORK IN EXTERIOR BUILDING WALLS ON THE WARM SIDE OF THE BUILDING AND VAPOR BARRIER. COORDINATE INSTALLATION OF BUILDING INSULATION TO RUN CONTINUOUS BETWEEN PIPING AND BUILDING WALL. Q. SUPPORT ALL DUCTWORK, PIPING AND EQUIPMENT FROM BUILDING STRUCTURE MEMBERS. ROUTE DUCT MAINS TIGHT TO STRUCTURE UNLESS NOTED OTHERWISE. HOLD PIPING TIGHT TO BOTTOM OF STRUCTURAL MEMBERS OR RUN THROUGH JOIST WEBS IF POSSIBLE. DO NOT USE WIRE OR PERFORATED METAL TO SUPPORT PIPING. DO NOT SUPPORT PIPING FROM OTHER PIPING, DUCTWORK, AND/OR ELECTRICAL CONDUITS. DO NOT SUPPORT FROM WOOD TONGUE AND GROOVE ROOF DECK. SUPPORT FROM BOTTOM CHORD OF BAR JOISTS ONLY AT PANEL POINTS. ALL COMPONENTS REQUIRING MAINTENANCE SHALL BE SUPPORTED IN SUCH A MANNER AS TO BE READILY ACCESSIBLE WITHOUT REMOVAL OF THE CEILING SYSTEM AND TO ALLOW FOR REMOVAL FROM THE SYSTEM WHEN SUCH REMOVAL IS REQUIRED FOR MAINTENANCE. R. PROVIDE CONSTRUCTION FILTERS ON AIR MOVING EQUIPMENT SERVING THE CONSTRUCTION AREA AS WELL AS ALL RETURN/EXHAUST DUCT PENETRATIONS COMING FROM THE CONSTRUCTION AREA. AT THE COMPLETION OF WORK, REMOVE ALL TEMPORARY AND CONSTRUCTION FILTERS AND PROVIDE NEW FILTERS FOR ALL AIR MOVING EQUIPMENT. S. PROTECT ALL DUCTWORK AND PIPING DURING CONSTRUCTION. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. AT A MINIMUM, DUCTWORK AND PIPING ENDS SHALL BE COVERED AND SEALED TO PREVENT THE COLLECTION OF DUST AND DEBRIS. CLEAN ALL INTERIOR SURFACES PRIOR TO INSTALLATION AND PROTECT ONCE INSTALLED. MEDICAL GAS PIPING SHALL BE PROTECTED IN ACCORDANCE WITH NFPA 99 REQUIREMENTS. T. AT THE COMPLETION OF WORK, CLEAN ALL STRAINERS PROVIDED AS A PART OF THE WORK AS WELL AS PRIMARY SYSTEM STRAINERS LOCATED AT PUMPS WHERE SYSTEMS WERE EXTENDED. ON EXISTING EQUIPMENT, COORDINATE WORK WITH OWNER. U. PROVIDE INTERMEDIATE TESTING AND BALANCING AT THE COMPLETION OF EACH PHASE AND AS REQUIRED TO MAINTAIN PROPER OPERATION OF SYSTEMS SERVING AREAS OF THE FACILITY IN USE INCLUDING BUT NOT LIMITED TO OCCUPIED AREAS, STORAGE AREAS, AND OTHER AREAS DEEMED CRITICAL BY THE OWNER OR AHJ. V. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED. REFER TO DETAIL SHEETS FOR GENERAL CONSTRUCTION DETAILS. W. REFER TO SCHEDULES FOR SIZES OF FINAL RUNOUTS TO EQUIPMENT, FIXTURES, DIFFUSERS, GRILLES, AND TERMINAL DEVICES. FINAL RUNOUT SIZES LISTED SHALL BE USED TO WITHIN 10 EQUIVALENT DIAMETERS OF FINAL CONNECTION POINT. FINAL PIPING CONNECTION TO EQUIPMENT SHALL MATCH EQUIPMENT CONNECTION SIZE, PROVIDE TRANSITIONS AS REQUIRED. REFER TO DETAILS, DIAGRAMS AND SCHEMATICS FOR ADDITIONAL FINAL CONNECTION REQUIREMENTS. REFER TO SCHEDULE SHEETS FOR PROVIDED SCHEDULES. X. FOR DUCTWORK PENETRATING A ONE HOUR FIRE RATED WALL WHERE A FIRE DAMPER IS NOT SHOWN, PROVIDE U.L. LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM THAT IS SPECIFIC TO THE WALL CONSTRUCTION ASSEMBLY AND COMPLIANT WITH ASTM E814. THE SYSTEM SHALL BE FIRE TESTED PER ASTM E119 AND COMPLY WITH EXCEPTION 1 OF 2018 IBC PART 717.5.2. INSTALL SYSTEM IN STRICT COMPLIANCE WITH THE FIRE STOPPING MANUFACTURER'S U.L. APPROVED DETAIL. WHERE EXISTING WALLS ARE BEING UPGRADED TO A ONE HOUR FIRE RATED WALL, PROVIDE U.L. LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM FOR ALL NEW AND EXISTING PENETRATIONS. REFER TO THE ARCHITECTURAL LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED WALLS. ALL DUCTWORK PENETRATIONS SHALL BE INSPECTED BY AN APPROVED THIRD PARTY INSPECTION AGENCY IN ACCORDANCE WITH ASTM E2174. THE INSPECTION AGENCY SHALL BE PROCURED BY THE CONTRACTOR. DOCUMENTATION OF APPROVED INSPECTION SHALL BE INCLUDED WITH PROJECT CLOSEOUT DOCUMENTATION. Y. FIRE ALARM CONTRACTOR SHALL PROVIDE A DUCT SMOKE DETECTOR FOR EACH SMOKE OR FIRE/SMOKE DAMPER AS REQUIRED BY CODE. MECHANICAL CONTRACTOR SHALL COORDINATE THE LOCATION OF EACH DUCT SMOKE DETECTOR AND SHALL INSTALL THEM IN THE DUCT. Z. FOR ALL PIPING, CONDUIT, AND OTHER ITEMS PENETRATING A FIRE RATED WALL, PROVIDE U.L. LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM THAT IS SPECIFIC TO THE WALL CONSTRUCTION ASSEMBLY AND COMPLIANT WITH ASTM E814. INSTALL SYSTEM IN STRICT COMPLIANCE WITH THE FIRE STOPPING MANUFACTURER'S U.L. APPROVED DETAIL.WHERE EXISTING WALLS ARE BEING UPGRADED TO FIRE RATED WALLS OR THE FIRE RATING IS BEING MODIFIED, PROVIDE U.L. LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM FOR ALL NEW AND EXISTING PENETRATIONS. REFER TO THE ARCHITECTURAL LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED WALLS. AA. CUTTING GRADE MOUNTED FLOORS: CONTRACTOR TO FIELD VERIFY LOCATION AND DEPTH OF EXISTING UTILITIES PRIOR TO SAWCUTTING FLOORS.CONTRACTOR SHALL X-RAY FLOOR, SCOPE PIPING AND USE OTHER APPROPRIATE MEANS TO IDENTIFY EXISTING CONDITIONS, PIPING, OR OTHER UTILITIES PRIOR TO COMMENCING WORK. FIRE PROTECTION GENERAL NOTES: A. FIRE PROTECTION WORK SHALL INCLUDE, BUT NOT LIMITED TO, THE FOLLOWING: MAINTAINING FIRE SPRINKLER COVERAGE FOR ALL AREAS IN THE SCOPE OF WORK. B. ALL AREAS OF THE BUILDING INDICATED SHALL BE SPRINKLERED ACCORDING TO THE CURRENTLY ADOPTED EDITION OF NFPA STANDARD 13 AND OTHER NFPA STANDARDS AS REQUIRED. ENTIRE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE STATE FIRE MARSHAL OFFICE, OWNER'S INSURANCE COMPANY AND AUTHORITIES HAVING JURISDICTION. C. FIRE SPRINKLER DESIGN SHALL BE BASED ON HYDRAULIC CALCULATIONS ACCORDING NFPA 13, WITH SHOP DRAWINGS PREPARED ACCORDING TO THE REQUIREMENTS OF THE STATE FIRE MARSHAL AND AUTHORITIES HAVING JURISDICTION. D. SPRINKLER CONTRACTOR SHALL OBTAIN STATIC AND RESIDUAL WATER PRESSURE AND FLOW PRIOR TO SYSTEM DESIGN AND SHALL SUBMIT RECENT HYDRANT FLOW TEST DATA WITH SHOP DRAWING SUBMITTALS. E. DRAWINGS ARE SCHEMATIC IN NATURE, INTENDED TO CONVEY THE SCOPE OF WORK AND GENERAL ARRANGEMENT OF THE SYSTEM. SPRINKLER SYSTEM INSTALLING CONTRACTOR SHALL COORDINATE SYSTEM ARRANGEMENT WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL COMPONENTS. SPRINKLER PIPING SHALL NOT BE INSTALLED BELOW MECHANICAL EQUIPMENT OR WITHIN CLEARANCE SPACES FOR MECHANICAL EQUIPMENT. PROVIDE SPRINKLER PROTECTION BELOW ALL DUCTS GREATER THAN 48 INCHES IN WIDTH. INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MODIFICATIONS TO THE SYSTEM REQUIRED TO AVOID CONFLICTS. F. AREAS IDENTIFIED INDICATE THE RECOMMENDED MINIMUM OCCUPANCY CLASSIFICATION, SPRINKLER TEMPERATURE CHARACTERISTIC OR SPRINKLER TYPES TO BE INSTALLED. SPRINKLER SYSTEM SHALL BE DESIGNED TO MEET OR EXCEED THESE RECOMMENDATIONS AND SHALL BE SUBJECT TO APPROVAL BY THE AUTHORITY HAVING JURISDICTION. G. A PRE-DESIGN MEETING SHALL BE COORDINATED WITH THE ARCHITECT PRIOR TO SUBMITTAL OF PIPING LAYOUT DRAWINGS. ARCHITECT SHALL ISSUE COMMENTS CONCERNING SUBMITTAL PACKAGE PRIOR TO COMMENCEMENT OF WORK. H. REFER TO ARCHITECTURAL PLANS FOR SPECIFIC CEILING TYPES AND HEIGHTS, AND AREAS OF EXPOSED STRUCTURE. I. COORDINATE PIPING AND SPRINKLERS IN EXPOSED AREAS TO MINIMIZE APPEARANCE. INSTALL SPRINKLERS A MINIMUM OF SIX INCHES FROM DIFFUSERS, GRILLES AND LIGHT FIXTURES. INSTALL SPRINKLERS IN LAY- IN CEILINGS WITHIN THREE INCHES OF THE CENTER OF CEILING TILE. J. COORDINATE INSTALLATION OF SPRINKLERS AND PIPING SYSTEMS TO AVOID FREEZING CONDITIONS. NOTIFY ARCHITECT OF AREAS FOR WHERE SYSTEM MAY BE EXPOSED TO FREEZING. INSTALL DRY SIDEW ALL SPRINKLERS IN ROOMS INDICATED WHERE ROOMS MAY BE UNCONDITIONED OR EXPOSED TO FREEZING CONDITIONS. PROVIDE AUXILIARY DRAINS WHERE REQUIRED. K. EXPOSED SPRINKLER PIPING, EXCEPT IN MECHANICAL AND STORAGE ROOMS, SHALL BE CLEANED, PRIMED AND PREPARED FOR PAINTING. L. AVOID ROUTING SPRINKLER PIPING ABOVE ELECTRICAL, DATA, IT AND COMMUNICATION PANELS. ABBREVIATION HVAC ABBREVIATIONS DESCRIPTION AIR BLENDERAB AIR CONDITIONING UNIT (SPLIT SYSTEM INDOOR UNIT)AC AIR HANDLING UNITAHU NOT ALL ABBREVIATIONS APPLY TO THIS SET OF DOCUMENTS BOILER FEED UNITBFU BOILERBLR CONSTANT AIR VOLUME BOXCAV COOLING COILCC CONDENSATE DRAINCD CUBIC FEET PER MINUTECFM CHILLERCH CONDENSATE PUMPCP CONDENSER WATER RETURNCR CONDENSER WATER SUPPLYCS COOLING TOWERCT CONDENSING UNITCU CABINET UNIT HEATERCUH CHILLED WATER RETURNCWR CHILLED WATER SUPPLYCWS DIFFUSERD DUAL DUCTDD DIRECT EXPANSIONDX EXHAUST AIREA ENTERING AIR TEMPERATUREEAT EXHAUST FANEF EFFICIENCYEFF ENERGY RECOVERY COILERC ENERGY RECOVERY WHEELERW EXPANSION TANKET ENTERING WATER TEMPERATUREEWT FILTER BANK (CONSISTING OF ONE OR MORE FILTERS)FB FAN COIL UNITFCU FLOW MEASURING STATIONFMS FUEL OIL RETURNFOR FUEL OIL SUPPLYFOS FUEL OIL VENTFOV FIRE DAMPERFRD FIRE SMOKE DAMPERFSD FINNED TUBE RADIATORFTR GRILLEG GLYCOL CHILLED WATER RETURNGCWR GLYCOL CHILLED WATER SUPPLYGCWS GRAVITY EXHAUSTGE GLYCOL HEATING HOT WATER RETURNGHWR GLYCOL HEATING HOT WATER SUPPLYGHWS GRAVITY INTAKEGI HEATING COILHC ABBREVIATION DESCRIPTION HORSEPOWERHP HIGH PRESSURE STEAM CONDENSATEHPC HIGH PRESSURE STEAM SUPPLY (86 PSIG AND ABOVE)HPS HEAT RECOVERY CHILLERHRC HUMIDIFIERHUM HEATING HOT WATER RETURNHWR HEATING HOT WATER SUPPLYHWS LOW PRESSURE STEAM CONDENSATELPC LOW PRESSURE STEAM SUPPLY (0-12 PSIG)LPS LOUVERLV LEAVING WATER TEMPERATURELWT BTU (1000'S)MBH MANUAL DAMPERMD MOTOR OPERATED DAMPERMOD MEDIUM PRESSURE STEAM CONDENSATEMPC MEDIUM PRESSURE STEAM SUPPLY (13-85 PSIG)MPS NORMALLY CLOSED, NOISE CRITERIANC NORMALLY OPEN, NUMBERNO OUTDOOR AIROA PUMPP PUMPED CONDENSATEPC PRESSURE REDUCING VALVEPRV PUMPED STEAM CONDENSATEPSC REGISTERR RETURN AIRRA RELIEF AIRREA REFRIGERANT DX LIQUIDREFL REFRIGERANT DX SUCTION GASREFS RETURN FANRF RELATIVE HUMIDITYRH ROOF TOP UNITRTU SUPPLY AIRSA SMOKE DAMPERSD SUPPLY FANSF STATIC PRESSURESP STEAMSTM TEMPERATURETEMP TRANSFERTR UNIT HEATERUH VARIABLE AIR VOLUME BOXVAV VENT THROUGH ROOFVTR WET BULB TEMPERATUREWB WATER COLUMNWC WATER PRESSURE DROPWPD WATER SOURCE HEAT PUMP RETURNWSHPR WATER SOURCE HEAT PUMP SUPPLYWSHPS RECTANGULAR DUCTWORK W = DIMENSION IN VIEW (INCHES) H = DIMENSION PERPENDICULAR TO VIEW (INCHES) ROUND DUCTWORK D = DUCT DIAMETER TURNING VANES WxH D"Ø HVAC SYMBOLS SYMBOL DESCRIPTION ADDITIONAL REMARKS REFER TO DUCT CONSTRUCTION SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. REFER TO DUCT CONSTRUCTION SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. DUCT CROSS SECTION -SUPPLY DUCT CROSS SECTION -RETURN DUCT CROSS SECTION -EXHAUST CROSS SECTION INDICATES DUCT EXTENDING PERPENDICULAR TO THE PAGE. IN PLAN VIEW THIS INDICATES A DUCT RISE OR DROP TO ANOTHER LEVEL. SOLID FILLED REGION INDICATE EXTENSION UP. NO FILLED REGION INDICATES EXTENSION DOWN. MANUAL BALANCE DAMPER REFER TO SPECIFICATIONS FOR TYPE. LOCATE MANUAL BALANCE DAMPERS IN AN ACCESSIBLE LOCATION AND AS CLOSE TO THE MAIN DUCT AS POSSIBLE. CONTROL DAMPER FIRE/SMOKE DAMPER REFER TO SPECIFICATIONS FOR TYPE. LOCATE DAMPERS IN AN ACCESSIBLE LOCATION AND PROVIDE ACCESS DOORS/PANELS IN DUCT AND CEILING/WALL. DIFFUSER FLEXIBLE DUCT REFER TO SPECIFICATIONS FOR TYPE. REFER TO DETAILS FOR INSTALLATION REQUIREMENTS. MAXIMUM LENGTH SHALL BE 48 INCHES UNLESS NOTED OTHERWISE ON THE PLANS OR IN THE SPECIFICATIONS. REFER TO SCHEDULE, DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION AND INSTALLATION REQUIREMENTS.VARIABLE AIR VOLUME BOX -NO COIL REFER TO SCHEDULE, DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION AND INSTALLATION REQUIREMENTS.VARIABLE AIR VOLUME BOX -HOT WATER COIL VB-# ### CFM VAV BOX TAG # = REFERENCE NUMBER IN SCHEDULE ### = AIRFLOW IN CFM REFER TO VARIABLE VOLUME BOX SCHEDULE FOR TYPES AND SIZING.AIRFLOW LISTED IS NOMINAL DESIGN CFM AND GPM.FINAL VALUES ARE TO BE DETERMINED BY TESTING AND BALANCING CONTRACTOR AND PROGRAMMED BY CONTROLS CONTRACTOR. VB-# #.# GPM VAV BOX TAG # = REFERENCE NUMBER IN SCHEDULE #.# = WATER FLOW RATE IN GPM REFER TO SCHEDULE, DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION AND INSTALLATION REQUIREMENTS.VARIABLE AIR VOLUME BOX -DUAL DUCT D# ### DIFFUSER TAG D = TYPE # = TYPE NUMBER ### = AIRFLOW IN CFM REFER TO DIFFUSER SCHEDULE FOR TYPE DESCRIPTIONS AND SIZING. BALANCE TO AIRFLOW LISTED. WHEN TYPE IS NOT GIVEN AND ONLY CFM IS DESIGNATED, PROVIDE D1 FOR SUPPLY OR G1 FOR RETURN/EXHAUST. FLOW ARROW ARROW INDICATES DIRECTION OF AIRFLOW FROM DIFFUSERS WITH ADJUSTABLE THROWS. DIFFUSER BLANK OFF SHADED AREA INDICATES QUADRANT OF DIFFUSER TO BE PROVIDED WITH BLANK OFF PANEL. RETURN GRILLE EXHAUST GRILLE WALL REGISTER / GRILLE DUCT MOUNTED REGISTER / GRILLE LINEAR SLOT REFER TO VARIABLE VOLUME BOX SCHEDULE FOR TYPES AND SIZING.AIRFLOW LISTED IS NOMINAL DESIGN CFM AND GPM.FINAL VALUES ARE TO BE DETERMINED BY TESTING AND BALANCING CONTRACTOR AND PROGRAMMED BY CONTROLS CONTRACTOR. SMOKE DAMPER REFER TO SPECIFICATIONS FOR TYPE. LOCATE DAMPERS IN AN ACCESSIBLE LOCATION AND PROVIDE ACCESS DOORS/PANELS IN DUCT AND CEILING/WALL. FIRE DAMPER REFER TO SPECIFICATIONS FOR TYPE. LOCATE DAMPERS IN AN ACCESSIBLE LOCATION AND PROVIDE ACCESS DOORS/PANELS IN DUCT AND CEILING/WALL. CD FD SD FS DAMPER SHALL BE SAME SIZE AS DUCT UNLESS NOTED OTHERWISE. REFER TO SEQUENCES, SCHEMATICS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. TRANSFER AIR ARROW ### = AIRFLOW IN CFM ARROW INDICATES DIRECTION OF TRANSFER AIR. UNION Y STRAINER WITH BLOWDOWN ELBOW UP ELBOW DOWN TEE UP PIPING -SOLID LINE INDICATES SYSTEM SUPPLY --DASHED LINE INDICATES SYSTEM RETURN NUMBER INDICATES NOMINAL DIAMETER IN INCHES, LETTER(S) INDICATES SYSTEM. REFER TO ABBREVIATIONS FOR SYSTEM TYPE. GENERAL MECHANICAL SYMBOLS SYMBOL DESCRIPTION ADDITIONAL REMARKS #SHEET NOTE DENOTES SPECIFIC REQUIREMENT FOR THE SHEET ON WHICH THE NOTE APPEARS AND IS USED TO DESCRIBE WORK THAT IS TOO LENGTHY TO PLACE ON PLAN. DIAMETER DENOTES CONNECTION OF NEW WORK TO EXISTING SYSTEM PROTECT EXISTING SYSTEM FROM ENTRANCE OF FOREIGN DEBRIS DURING WORK. ARROW INDICATES DOWNWARD PIPE SLOPE #/# INDICATES SLOPE IN INCHES PER FOOT WHERE PIPING IS NOT MARKED, REFER TO SPECIFICATIONS FOR REQUIREMENTS ARROW INDICATES DIRECTION OF FLOW IN PIPING ISOLATION VALVE REFER TO SPECIFICATIONS FOR TYPE BASED ON SIZE AND SYSTEM CHECK VALVE OR BACKWATER VALVE ARROW INDICATES DIRECTION OF NORMAL FLOW REFER TO SPECIFICATIONS FOR TYPE BASED ON SIZE AND SYSTEM PIPE IN SLEEVE REFER TO SPECIFICATIONS FOR TYPE BASED ON SIZE AND SYSTEM CIRCUIT SETTER, AUTOFLOW, ETC. REFER TO SPECIFICATIONS FOR TYPE BASED ON SIZE AND SYSTEM PRESSURE GAUGE REFER TO SPECIFICATIONS FOR TYPE AND ACCESSORIES REFER TO SPECIFICATIONS FOR TYPE AND ACCESSORIES REFER TO SPECIFICATIONS FOR TYPE AND ACCESSORIESTHERMOMETER -HORIZONTAL PIPE TEE DOWN TEE HORIZONTAL PIPE REDUCER INDICATES POINT WHERE PIPING CHANGES FROM ONE SIZE TO ANOTHER. SMALL POINT OF ARROW INDICATES SMALLER SIZE SIDE OF TRANSITION. REQUIRED SERVICE CLEARANCE FOR EQUIPMENT DUCT CONTINUATION AIR VENT AUTOMATIC FLOW CONTROL VALVE # INDICATES FLOW TO BE BALANCED IN GPM BACKFLOW PREVENTER CALIBRATED BALANCING VALVE VALVE -THROTTLING SERVICE VALVE -SHUTOFF SERVICE P/T PORT PIPE CAP PIPE CONTINUATION PRESSURE GAUGE STEAM REFER TO SPECIFICATIONS FOR TYPE AND ACCESSORIES PRESSURE REDUCING VALVE PUMP RELIEF VALVE S SENSOR SUCTION DIFFUSER THERMOMETER -VERTICAL PIPE REFER TO SPECIFICATIONS FOR TYPE AND ACCESSORIES VACUUM BREAKER Y STRAINER ABBREVIATION GENERAL ABBREVIATIONS DESCRIPTION NOT ALL ABBREVIATIONS APPLY TO THIS SET OF DOCUMENTS AD ACCESS DOOR/PANEL AFF ABOVE FINISHED FLOOR AMB AMBIENT DIA DIAMETER DN DOWN E EXISTING EC ELECTRICAL CONTRACTOR EFF EFFICIENCY GC GENERAL CONTRACTOR FPM FEET PER MINUTE FPS FEET PER SECOND L LENGTH GPM GALLONS PER MINUTE BOB BOTTOM OF BEAM CC CONTROLS CONTRACTOR ABBREVIATION DESCRIPTION LF LINEAR FEET MAX MAXIMUM MC MECHANICAL CONTRACTOR MFR MANUFACTURER MIN MINIMUM NIC NOT IN CONTRACT NTS NOT TO SCALE PC PLUMBING CONTRACTOR PSIG POUNDS PER SQUARE INCH GAUGE RPM REVOLUTIONS PER MINUTE SHT SHEET TOB TOP OF BEAM TOS TOP OF STEEL VEL VELOCITY VFD VARIABLE FREQUENCY DRIVE PRESSURE/TEMPERATURE TEST PORT # TEMPERATURE CONTROL SYMBOLS SYMBOL DESCRIPTION ADDITIONAL REMARKS WALL MOUNTED CONTROL DEVICE # INDICATES TYPE REFER TO MOUNTING HEIGHTS DETAIL FOR MOUNTING ELEVATION. T = THERMOSTAT H = HUMIDISTAT S = SENSOR (CARBON MONOXIDE, ETC.) OCCUPANCY SENSOR REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. WHEN SENSOR IS NOT SHOWN ON ELECTRICAL DRAWINGS IT SHALL BE PROVIDED AND INSTALLED BY THE TEMPERATURE CONTROLS CONTRACTOR. #DUCT, PIPE, OR CEILING MOUNTED CONTROL SENSOR REFER TO SPECIFICATIONS FOR TYPE. REFER TO SEQUENCES AND SCHEMATICS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. T = THERMOSTAT H = HUMIDISTAT S = SENSOR (CARBON DIOXIDE, ETC.) CONTROL VALVE (3-WAY) CONTROL VALVE (2-WAY) REFER TO SPECIFICATIONS FOR TYPE. REFER TO SEQUENCES AND SCHEMATICS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. REFER TO SPECIFICATIONS FOR TYPE. REFER TO SEQUENCES AND SCHEMATICS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 NO SCALE Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/25/2024 1:48:12 PM 1/25/2024 1:48:12 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt M000 01/24/2024 23289 MECHANICAL SYMBOLS AND ABBREVIATIONS KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 11/08/2024 MECHANICAL DRAWING SPECIFICATION INDEX 200500 -GENERAL PROVISIONS 200510 -BASIC MATERIALS AND METHODS 200553 -MECHANICAL IDENTIFICATION 200700 -INSULATION 211313 -FIRE PROTECTION AND SPRINKLER SYSTEMS 226313 -MEDICAL GAS PIPING SYSTEMS 232100 -HEAT GENERATION, REFRIGERATION AND LIQUID HEAT TRANSFER 233110 -AIR DISTRIBUTION 230900 -CONTROLS AND INSTRUMENTATION 230593 -TESTING, ADJUSTING AND BALANCING SECTION 200500 GENERAL PROVISIONS GENERAL 1.01 SCOPE OF WORK A. WORK SHALL CONSIST OF FURNISHING ALL LABOR AND MATERIALS NECESSARY FOR THE INSTALLATION OF COMPLETE AND OPERATING MECHANICAL SYSTEMS. COORDINATE AND ORDER THE PROGRESS OF MECHANICAL WORK TO CONFORM TO THE PROGRESS OF THE OTHER TRADES. 1.02 EXAMINATION OF PREMISES A. THE CONTRACTOR IS RESPONSIBLE TO; VISIT THE SITE PRIOR TO BID, BECOME FAMILIAR WITH THE EXTENT OF THE WORK REQUIRED, VERIFY DIMENSIONS, AND VERIFY EXISTING CONDITIONS RELATED TO THE WORK, INCLUDING THOSE CONDITIONS ABOVE CEILINGS. NO EXTRAS WILL BE ALLOWED FOR A LACK OF KNOWLEDGE OF EXISTING CONDITIONS OR CHANGES OF A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY CONTRACT DOCUMENTS. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SITE CONDITIONS TO THE OWNER PRIOR TO BID. 1.03 CODES AND STANDARDS A. COMPLY WITH ALL CURRENT APPLICABLE STATE AND LOCAL CODES, LAWS, INDUSTRY STANDARDS, HEALTHCARE STANDARDS AND UTILITY COMPANY REGULATIONS AND THE AVH FACILITY STANDARDS. 1.04 UTILITIES INTERRUPTIONS A. COORDINATE ALL MECHANICAL UTILITY INTERRUPTIONS WITH THE OWNER’S PROJECT MANAGER. PLAN THE WORK SO THAT THE DURATION OF THE INTERRUPTION IS KEPT TO A MINIMUM. 1.05 EQUIPMENT FURNISHED BY OTHERS A. CONTRACTOR IS TO PROVIDE COMPLETE CONNECTIONS TO ALL NEW AND RELOCATED OWNER FURNISHED EQUIPMENT. REFER TO BOTH THE MECHANICAL AND ARCHITECTURAL DRAWINGS. 1.06 PERMITS, FEES AND NOTICES A. PAY FOR ALL PERMITS, FEES, LICENSES AND INSPECTIONS FOR THIS DIVISION. 1.07 DRAWINGS A. MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO BE SCALED FOR DIMENSIONS. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS, CERTIFIED EQUIPMENT DRAWINGS AND FROM THE STRUCTURE ITSELF BEFORE FABRICATING ANY WORK. VERIFY ALL SPACE REQUIREMENTS, COORDINATE WITH OTHER TRADES, AND INSTALL THE SYSTEMS COMPLETE IN THE SPACE ALLOWED W ITHOUT EXTRA CHARGES TO THE OWNER. B. THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF THE EXISTING EQUIPMENT LOCATIONS, EXISTING PIPE ROUTING AND EXISTING DUCT ROUTING. THE INFORMATION SHOWN HAS BEEN ASCERTAINED FROM ARCHIVE DRAWINGS AND FIELD OBSERVATIONS AND IS AS ACCURATE AS CONDITIONS WOULD ALLOW. 1.08 SHOP DRAWINGS A. SUBMIT SAMPLES, SHOP DRAWINGS AND PRODUCT DATA AS REQUIRED BY VARIOUS SECTIONS OF DIVISIONS 20 THRU 23 IN ACCORDANCE WITH THE ARCHITECTURAL DIVISIONS. MAKE SUBMITTALS TO ARCHITECT, NOT DIRECTLY TO MECHANICAL ENGINEER. B. SUBMIT SHOP DRAWINGS FOR ALL MATERIALS AND EQUIPMENT NAMED IN THESE SPECIFICATIONS, SHOWING ANY CHANGES REQUIRED. SUBMIT AT LEAST 3 COPIES. C. INCLUDE COPIES OF THESE ITEMS IN THE OPERATING AND MAINTENANCE MANUALS. 1.09 SUBSTITUTIONS AND APPROVALS A. SOME MATERIALS ARE SPECIFIED BY MANUFACTURER’S NAME. MATERIALS OF EQUIVALENT QUALITY MAY BE USED IF PRIOR APPROVED. B. BIDDER’S CHOICE MATERIALS OR EQUIPMENT LISTED BY SEVERAL MANUFACTURERS’NAMES ARE INTENDED TO BE BIDDER’S CHOICE, AND ANY OF THE LISTED MANUFACTURERS MAY BE BID WITHOUT SOLICITING PRIOR APPROVAL. C.PERFORMANCE SPECIFICATION WHEN ANY ITEM IS SPECIFIED BY EQUIPMENT TO MEET A PERFORMANCE, INDUSTRY OR REGULATING BODY STANDARD OR IS SPECIFIED BY A GENERIC SPEC (NO MANUFACTURER’S NAME LISTED), NO PRIOR APPROVAL BY THE CONSULTING MECHANICAL ENGINEER IS NEEDED UNLESS SPECIFICALLY CALLED FOR IN THESE SPECIFICATIONS. D.SUBSTITUTIONS a. ACTION FOR SUBSTITUTIONS SPECIFIED HEREIN WILL BE GIVEN ONLY AFTER THE RECEIPT OF COMPLETE DATA SHOWING PERFORMANCE OVER ENTIRE RANGE, MAKE AND PROJECT MANUAL IDENTIFICATION NUMBER, PHYSICAL DIMENSIONS AND MATERIAL CONSTRUCTION ALL SPECIFICALLY MARKED FOR THE INDIVIDUAL ITEM. LETTER OF TRANSMITTAL WITH AT LEAST ONE (1) COPY OF ALL DESCRIPTIVE DATA SHALL BE SUBMITTED TO THE CONSULTING MECHANICAL ENGINEER'S OFFICE. DATA MAY NOT BE RETURNED; REFERENCE ADDENDA FOR APPROVAL TO BID. b. COMPLY WITH DIVISION 01 c. MATERIALS, EQUIPMENT OR SERVICES LISTED BY SEVERAL IDENTIFYING NAMES ARE INTENDED TO BE BIDDER'S CHOICE, AND ANY OF THE LISTED NAMES MAY BE BID WITHOUT SOLICITING PRIOR ACCEPTANCE. WHERE MORE THAN ONE NAME IS GIVEN IN THE SPECIFICATIONS, THE FIRST NAMED MANUFACTURER'S MATERIAL, EQUIPMENT OR SERVICE IS CONTEMPLATED AND ANY CHANGES AND THE COSTS, REQUIRED TO ACCOMMODATE THE OTHER NAMED MATERIAL OR EQUIPMENT AS WELL AS SPACE REQUIREMENTS FOR THE OTHER NAMED MATERIALS OR EQUIPMENT, MUST BE ASSUMED BY THE CONTRACTOR IN HIS BID. d. MATERIAL AND EQUIPMENT SPECIFIED IS USED AS A BASIS OF STANDARD, AND WHILE NOT SPECIFICALLY MENTIONED, MATERIAL GAUGES, WEIGHTS, APPEARANCE AND SPACE REQUIREMENTS MUST BE MET BY ANY SUBSTITUTIONS. E.CONTRACTOR TO BE RESPONSIBLE FOR ANY CHANGES AND COSTS TO ACCOMMODATE ANY EQUIPMENT EXCEPT THE FIRST NAMED IN THE SPECIFICATION. 1.10 DEMOLITION A. ALL EXISTING EQUIPMENT AND MATERIALS CALLED TO BE REMOVED UNDER THIS CONTRACT SHALL BE REMOVED FROM OCCUPIED SPACES DAILY. B. ALL PIPING AND DUCTS INDICATED TO BE REMOVED UNDER THIS CONTRACT SHALL BE REMOVED COMPLETELY TO POINTS OF CONNECTION AT THE MAINS OR BRANCHES AND CAPPED. C. ALL FIXTURES, EQUIPMENT, CEILING DEVICES, ETC. REMOVED AND NOT REUSED ARE TO BE RETURNED TO OWNER. DISPOSE OF ALL REMOVED ITEMS NOT RETAINED BY THE OWNER. 1.11 INSTALLATION AND ARRANGEMENT A. INSTALL ALL WORK TO PERMIT REMOVAL OF COILS, SHAFTS AND WHEELS, FILTERS AND ALL OTHER PARTS WHICH MIGHT REQUIRE PERIODIC REPLACEMENT OR MAINTENANCE. B. INSTALL WORK TO AVOID INTERFERENCE WITH EXISTING FACILITIES, EQUIPMENT, DUCTS AND PIPING. C. CONTRACTOR IS RESPONSIBLE FOR RAISING OR LOWERING EXISTING EQUIPMENT AND MAKING PROPER OFFSETS IN DUCTS AND PIPING TO AVOID CONFLICTS. D. COORDINATE THE LOCATION OF ALL DUCTWORK, PIPING AND CEILING DEVICES WITH OTHER TRADES, REFLECTED CEILING PLANS AND STRUCTURE PRIOR TO BEGINNING WORK. E. ALL CUTTING, PATCHING AND CORE DRILLING FOR THE INSTALLATION OF EQUIPMENT, DUCTS, HANGERS, ETC. SHALL BE HELD TO A MINIMUM AND BE ACCOMPLISHED IN A CAREFUL MANNER. ALL PATCHING SHALL MATCH EXISTING CONSTRUCTION, TEXTURE AND FINISH AND BE DONE BY SKILLED CRAFTSMAN OF THE TRADES INVOLVED AT THE CONTRACTOR'S EXPENSE. F. THE INSTALLATION OF DUCTS, PIPES AND EQUIPMENT MAY REQUIRE THE REMOVAL OF EXISTING WALLS AND CEILINGS. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING THESE WALLS AND/OR CEILINGS SO THEY MATCH THE EXISTING WHERE NOT REPLACED UNDER THE ARCHITECTURAL DIVISION. 1.12 PROTECTION OF WORK AND PROPERTY A. BE RESPONSIBLE FOR THE PROTECTION OF EXISTING FACILITIES WHETHER OR NOT SUCH FACILITY IS TO BE REMOVED OR RELOCATED. MOVE OR REMOVE ANY FACILITY SO AS NOT TO CAUSE INTERRUPTION OF THE WORK OR OWNER’S OPERATION. B. CLOSE ENDS OF PIPES AND DUCTWORK DURING CONSTRUCTION WITH CAPS OR PLUG TO PREVENT ENTRY OF FOREIGN MATERIAL. C. PROTECT INSULATION AGAINST DIRT, WATER OR OTHER DAMAGE BEFORE, DURING AND AFTER INSTALLATION. D. PROTECT FIXTURES AND EQUIPMENT AGAINST DAMAGE DURING MECHANICAL WORK. 1.13 WARRANTY A. ALL MATERIALS AND EQUIPMENT SHALL BE NEW UNLESS OTHERWISE SPECIFIED. GUARANTEE ALL WORKMANSHIP, MATERIAL AND EQUIPMENT AND REPLACE ANY FOUND DEFECTIVE WITHOUT COST TO THE OWNER, FOR ONE YEAR AFTER FINAL ACCEPTANCE, AS DEFINED IN GENERAL CONDITIONS. B. EACH WARRANTY FOR LONGER THAN THE ONE YEAR DESCRIBED ABOVE (THAT COMES WITH EQUIPMENT USED ON THE JOB) SHALL BE PASSED ONTO THE OWNER WITH DATES OF START AND END OF WARRANTY. 1.14 PROJECT RECORD DRAWINGS A. PROVIDE THE ARCHITECT WITH ONE CLEAN SET OF PLANS AND SPECIFICATIONS CORRECTED UP-TO-DATE AS JOB PROGRESSES. 1.15 CONTRACT CLOSEOUT PROCEDURE A. APPROVAL FOR FINAL PAYMENT WILL NOT BE GIVEN UNTIL THE FOLLOWING ITEMS HAVE BEEN SUBMITTED AND REVIEWED: a. PROJECT RECORD DRAWINGS b. RECORD OF PIPING AND DUCTWORK TESTS c. OPERATION AND MAINTENANCE MANUALS d. BALANCE REPORT e. ALL PUNCH ITEMS COMPLETED AND APPROVED BY OWNER END OF SECTION SECTION 200510 BASIC MATERIALS AND METHODS GENERAL 1.01 SCOPE OF WORK A. INCLUDES a. PIPE SUPPORTS, ANCHORS AND SEALS b. VALVES c. PIPE INSTALLATION d. PIPE AND DUCTWORK TESTING e. FLUSHING, CLEANING AND STERILIZING f. VIBRATION ISOLATION B. REFERENCE STANDARDS AND CODES a. COMPLY WITH SECTION 200500 b. THE COLORADO PRIMARY DRINKING REGULATIONS, 1991 c. AWWA STANDARD C651-86, DISINFECTING WATER MAINS, 1986 PRODUCTS 2.01 EQUIPMENT MANUFACTURERS EQUIPMENT IN EACH OF THE FOLLOWING CATEGORIES SHALL BE OF ONE MANUFACTURER OR AVAILABLE THRU ONE MANUFACTURER (OR VENDOR) FOR EACH CATEGORY TO FACILITATE EASE OF MAINTENANCE FOR THE OWNER. A. PLUMBING FIXTURE TRIM B. BALL, PLUG AND BUTTERFLY VALVES C. BALANCING VALVES D. DIELECTRIC UNIONS E. AIR FILTERS F. CALIBRATED ORIFICE BALANCING VALVE G. AUTOMATIC FLOW CONTROL VALVE 2.02 PIPE SUPPORTS AND HANGERS A. GENERAL USE ADJUSTABLE PIPE HANGERS ON SUSPENDED PIPE. CHAIN OR PERFORATED STRAP HANGERS WILL NOT BE PERMITTED. PROVIDE HANGERS TO SUPPORT THE SYSTEMS WITHOUT SAGGING, INCLUDING HANGERS AT EACH OFFSET OR CHANGE IN DIRECTION, AT ENDS OF BRANCHES OVER FIVE FEET IN LENGTH AND AT THE FOLLOWING MAXIMUM SPACING: PIPE TYPE PIPE SIZE MAXIMUM SPACING MINIMUM HANGER ROD SIZE STEEL PIPE 1/2"6' 0"3/8" 3/4"THROUGH 1-1/4"8' 0"3/8" 1-1/2" THROUGH 2"10' 0"3/8" 2-1/2" THROUGH 3"10' 0"1/2" 4" AND 5"10' 0"5/8" COPPER PIPE 1/2"THROUGH 1-1/2"6' 0"3/8" 2" AND ABOVE 10' 0"3/8" CAST IRON PIPE 2"1 EACH JOINT 3/8" 3"1 EACH JOINT 1/2" NOTE: HANGER RODS SHALL BE CONTINUOUS THREADED STEEL. RODS MAY BE REDUCED ONE SIZE FOR DOUBLE ROD HANGERS WITH 3/8”AS A MINIMUM DIAMETER. B.INDIVIDUAL HANGERS a.INDIVIDUAL HANGERS FOR NON-INSULATED STEEL OR PIPING SHALL BE COPPER PLATED OR PLASTIC COATED STEEL, ADJUSTABLE SWIVEL RING HANGERS b.INDIVIDUAL HANGERS FOR INSULATED STEEL OR COPPER PIPING SHALL BE ZINC PLATED, ADJUSTABLE SWIVEL RING HANGERS FOR PIPE SIZES UP THROUGH 1 ½”AND WROUGHT STEEL, ADJUSTABLE CLEVIS HANGERS FOR PIPE SIZES 2”AND OVER. C.TRAPEZE HANGERS a. PARALLEL RUNS OF PIPING MAY BE SUPPORTED ON TRAPEZE HANGERS. TRAPEZE SHALL BE UNISTRUT P-1000 OR EQUIVALENT BY B-LINE OR SUPERSTRUT. SYSTEM SHALL BE SELECTED TO SUPPORT FIVE TIMES THE WEIGHT OR THRUST APPLIED WITHOUT FAILURE. WHERE TRAPEZE LENGTH EXCEEDS FOUR FEET, PROVIDE ADDITIONAL HANGER ROD AT MID SPAN. HANGERS SHALL BE SPACED FOR SMALLEST PIPE IN GROUP. b. ALL NON-INSULATED STEEL PIPES SHALL HAVE STANDARD PIPE CLAMPS AT EACH SUPPORT. c. ALL INSULATED PIPE (STEEL OR COPPER) SHALL HAVE STANDARD PIPE STRAPS OVER THE HIGH DENSITY INSULATION INSERTS AT EACH SUPPORT. D.INSULATED PIPE SUPPORTS WHERE INDIVIDUAL HANGERS ARE USED PROTECT ALL INSULATED PIPE AT POINT OF SUPPORT WITH A 360 OR180 DEGREE INSULATION INSERT OF HIGH DENSITY POLYURETHANE FOAM, WATER-PROOFED 140 PSI CALCIUM SILICATE, OR EXPANDED PERLITE. ADHESIVE SHALL COMPLY WITH NFPA-90A, FLAME SPREAD 10/SMOKE 0. PROVIDE MINIMUM G-60 GALVANIZED SHIELD FOR HIGH DENSITY INSERT. WHERE TRAPEZE HANGERS ARE USED, PROTECT ALL INSULATED PIPE AT POINT OF SUPPORT WITH 360 DEGREES INSULATING INSERT. ENCASE INSULATION IN A 360 DEGREE SHEET METAL SHIELD. WHERE INSULATION STOPS AND STARTS FOR PIPE CLAMPS, ENDS OF INSULATION SHALL BE SEALED WITH LIQUID MASTIC TO PROVIDE CONTINUOUS VAPOR BARRIER. INSERT TO BE SAME THICKNESS AS ADJOINING PIPE INSULATION AND BE DIVIDED INTO LONGITUDINAL HALF SECTIONS AS APPLICABLE AND COVERED WITH FIRE RESISTANT VAPOR BARRIER JACKET. INSULATION INSERT FOR ALL COLD LIQUID (60°F OR BELOW) SHALL EXTEND 1 INCH BEYOND SHEET METAL SHIELD ON EACH END. SHIELD LENGTH AND MINIMUM SHEET METAL GAUGES SHOWN IN CHART BELOW. WHEN PIPE HANGER SPACING EXCEEDS 10FT., AND FOR ALL PIPE ROLLER APPLICATIONS, UTILIZE A DOUBLE LAYER SHIELD. PIPE TYPE SHIELD LENGTH MINIMUM GAUGE 1/2" THROUGH 1-1/2"4"22 2" THROUGH 6"6"20 E.WALL SUPPORTS a. 1/2”THROUGH 3”–CAST IRON HOOK b. UNISTRUT MAY BE USED FOR MULTIPLE PIPE RUNS UP TO 3”IN SIZE. F.VERTICAL SUPPORTS PROVIDE FRICTION RISER CLAMPS, SUPPORTED AND BRACED. CLAMPS FOR COPPER PIPING SHALL BE PLASTIC COATED STEEL. COPPER PIPES SHALL BE WRAPPED IN 3M SCOTCH RAP 50 APPLIED TO A 50MIL THICKNESS EXTENDED ½”BEYOND CLAMP EDGE. G.SLEEVES a. SCHEDULE 40 STEEL PIPE (GALVANIZED IF USED BELOW GRADE OR IN OUTSIDE WALL) OR PLASTIC SLEEVES MANUFACTURED BY PSI/THUNDERLINE SIZED LARGE ENOUGH TO ALLOW FOR MOVEMENT AND FOR CONTINUOUS INSULATION. SHEET METAL SLEEVES ARE NOT ALLOWED. SLEEVES USED BELOW GRADE AND FOR PENETRATION OF WATER PROOFED WALLS SHALL CONTAIN INTEGRAL WATER STOP. SEAL SPACE BETWEEN PIPE AND SLEEVE WITH LINK SEAL COMPRESSIBLE LINKED RUBBER SEALS. b. IN ADDITION TO SCHEDULE 40 SLEEVES, PREFABRICATED FIRE RATED THROUGH PENETRATION FIRE STOP DEVICES AND THROUGH PENETRATION FIRE STOP SYSTEMS FOR EACH SPECIFIED AND PARTICULAR PIPING OR CONDUIT MATERIAL FOR FIRE RATED PENETRATIONS SHALL BE ALLOWED. SYSTEM SHALL BE AS MANUFACTURED BY PROSET SYSTEMS OR APPROVED EQUIVALENT. 2.03 VALVES A.PRESSURE RATINGS UNLESS OTHERWISE INDICATED, USE VALVES SUITABLE FOR MINIMUM 125 PSIG AT 450°F AND 200 PSIG AT 250°F. B.VALVE CONNECTIONS a. PROVIDE VALVES SUITABLE TO CONNECT TO ADJOINING PIPING AS SPECIFIED FOR PIPE JOINTS. b. THREAD PIPE SIZES 2”AND SMALLER. c. SOLDER AND SCREW TO SOLDER ADAPTORS FOR COPPER TUBING. d. USE GROOVED BODY VALVES WITH MECHANICAL GROOVED JOINTED PIPING. C. VALVE OPERATORS PROVIDE ADJUSTABLE MEMORY STOPS FOR ALL VALVES USED IN BALANCING SERVICE EXECUTION 3.01 CUTTING AND PATCHING BE RESPONSIBLE FOR THE COST OF CUTTING AND PATCHING FOR WORK UNDER THE MECHANICAL DIVISION CAUSED BY IMPROPER COORDINATION OR NOTIFICATION. 3.02 PIPE AND DUCTWORK PENETRATIONS A. WHERE HORIZONTAL DUCTS AND PIPE PASS THROUGH WALLS, AND VERTICAL DUCTS AND PIPES PASS THROUGH FLOORS OR ROOFS SEAL OFF VOID BETWEEN OPENING AND DUCT, OR PIPE AND SLEEVE. B. WHEREVER ANY PIPE, DUCT, CONDUIT, STEEL MEMBER, BRACKET, EQUIPMENT OR OTHER MATERIAL PENETRATES OR PASSES THROUGH FIRE-RESISTANT WALL, CEILING OR FLOOR, COMPLETELY SEAL VOIDS IN CONSTRUCTION WITH NON-HARDENING CAULK OR OTHER FIRE RESISTANT MATERIAL AS APPROVED BY ALL AUTHORITIES HAVING JURISDICTION. EMBED SEALING MATERIAL FULL THICKNESS OF MATERIAL BEING PENETRATED. SEALANTS USED AT PENETRATIONS OF ITEMS WHICH CAN BE CONSUMED IN A FIRE SHALL BE INTUMESCENT AND SHALL BE INSTALLED SO AS TO FILL THE VOID LEFT IF PENETRANT IS CONSUMED. SEALANTS TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS AND SHALL HAVE BEEN TESTED AND CLASSIFIED BY UNDERWRITERS LABORATORIES. 3.03 EQUIPMENT CONNECTIONS WHERE THE INLET OR OUTLET OF TERMINAL EQUIPMENT, OR INLET OR OUTLET OF HEATING OR COOLING GENERATION EQUIPMENT IS SMALLER THEN THE PIPE SIZE NOTED ON THE DRAWINGS, ALL STRAINERS, VALVES, FLEXIBLE CONNECTIONS, EXPANSION JOINTS, ETC., SHALL BE A MINIMUM OF THE PIPE SIZE NOTED ON THE DRAWINGS. 3.04 PIPE INSTALLATION A. INSTALLATION a. INSTALL PIPING WITHOUT SPRINGING OR FORCING, AND TO CLEAR WINDOWS, DOORS, AND OTHER OPENINGS. CUTTING OR OTHER WEAKENING OF THE BUILDING STRUCTURE TO FACILITATE PIPING INSTALLATION IS NOT PERMITTED. b. PROVIDE SUFFICIENT SWING JOINTS, ANCHORS, EXPANSION LOOPS AND DEVICES NECESSARY TO PERMIT FREE EXPANSION AND CONTRADICTION WITHOUT CAUSING UNDUE STRESSES. MAKE CHANGES IN DIRECTION WITH FITTINGS. SUPPORT PIPING INDEPENDENTLY AT EQUIPMENT SO ITS WEIGHT WILL NOT BE SUPPORTED BY THE EQUIPMENT. c. INSTALL VERTICAL RISERS PLUMB AND STRAIGHT, HORIZONTAL LINES PARALLEL WITH WALLS AND PARTITIONS CONCEAL PIPING ABOVE CEILINGS AND WITHIN FURRING AND WALLS UNLESS OTHERWISE INDICATED. d. ALL PIPING SHALL BE RUN FULL SIZE AS INDICATED ON DRAWINGS. ANY REDUCTIONS IN PIPING REQUIRED BY EQUIPMENT CONNECTIONS SHALL BE MADE AT THESE CONNECTION POINTS. B. CLEARANCE PROVIDE CLEARANCE FOR PROPER INSTALLATION OF INSULATION AND FOR ACCESS TO VALVES, AIR VENTS, DRAINS AND UNIONS. PROVIDE MINIMUM 1/2”CLEARANCE BETWEEN PIPES AFTER INSULATION. C.SHUT-OFF VALVES AND UNIONS a. WHERE INDICATED, PROVIDE SHUTOFF VALVES AND UNIONS SUITABLY LOCATED, TO ISOLATE EACH ITEM OF EQUIPMENT, BRANCH CIRCUIT OR SECTION OF PIPING. b. PROVIDE DIELECTRIC UNIONS AT JUNCTIONS OF DISSIMILAR METALS. D.ROUTES AND GRADES a. ROUTE PIPING IN GENERAL LOCATIONS INDICATED, IN AN ORDERLY MANNER AND TO MAINTAIN REQUIRED GRADES. COORDINATE WITH OTHER PIPING, CONDUITS, DUCTS AND EQUIPMENT MAKING NECESSARY OFFSETS TO ACCOMMODATE THE SAME. b. INSTALL PIPING TO CONSERVE HEADROOM AND INTERFERE AS LITTLE AS POSSIBLE WITH USE OF AVAILABLE SPACE. GROUP PIPING WHEREVER POSSIBLE AT COMMON ELEVATIONS. INSTALL CONCEALED PIPES CLOSE TO THE BUILDING STRUCTURE TO KEEP FURRING TO A MINIMUM 3.05 INSTALLATION OF PIPE HANGERS A.USE HANGERS WHICH ARE VERTICALLY ADJUSTABLE 1 ½”MINIMUM AFTER PIPING IS ERECTED. B.INSULATION SHALL BE CARRIED FULL SIZE THROUGH THE HANGERS. 3.06 VALVES A.INSTALL VALVES WITH STEMS UPRIGHT OR HORIZONTAL, NOT INVERTED. B.PROVIDE DRAIN VALVES AT MAIN SHUT OFF VALVES, LOW POINTS OF PIPING AND EQUIPMENT. 3.07 PIPE AND DUCTWORK TESTING A.TEST PIPING AND DUCTWORK SYSTEMS PRIOR TO CONCEALMENT. ENSURE THAT THE TEST PRESSURE WHICH MIGHT DAMAGE FIXTURES, EXISTING PIPING OR EQUIPMENT DOES NOT REACH SUCH UNITS BY VALVING THEM OFF OR OTHERWISE ISOLATING THEM DURING THE TEST KEEP WRITTEN FIELD RECORDS OF ALL TESTS. EACH RECORD, SHALL CONTAIN, AS A MINIMUM, THE DATE OF THE TEST, SYSTEM OR SUBSYSTEM TESTED, TEST MEDIUM AND PRESSURE, DURATION OF TESTS, TEST RESULTS, NAME AND SIGNATURE OF INDIVIDUAL PERFORMING TEST, AND THE NAME AND SIGNATURE OF WITNESS TO THE TEST WHO IS NOT AN EMPLOYEE OF THE FIRM PERFORMING THE TEST. SUBMIT COPIES OF ALL TESTS TO ARCHITECT. ALL TESTS MUST BE DONE TO THE SATISFACTION OF THE OWNER’S REPRESENTATIVE AND LOCAL AUTHORITIES HAVING JURISDICTION, BEFORE COVERING. FURNISH ALL INSTRUMENTS REQUIRED FOR TESTING. ALL HYDROSTATIC TESTS ARE TO BE HELD FOR A MINIMUM OF SIX (6) HOURS WITHOUT LOSS OF PRESSURE. AIR TESTS ARE TO BE HELD FOR A MINIMUM OF (2) HOURS WITHOUT LOSS OF PRESSURE. ANY VISIBLE LEAKAGE OR APPRECIABLE PRESSURE DROP DURING THE TEST WILL BE CAUSE FOR REJECTING THE TEST. ADDITIONAL TESTS WILL BE REQUIRED AFTER CORRECTIVE MEASURES HAVE BEEN TAKEN UNTIL SATISFACTORY RESULTS ARE OBTAINED. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING ALL PLUGS, PIPING, VALVES, HOSES AND PUMPS NECESSARY FOR THE REQUIRED TESTS AND FOR PROPER DISPOSAL OF THE WATER UPON COMPLETION OF THE TESTS. B.TEST ALL DRAIN, WASTE AND ROOF DRAIN LINES WITH STANDING WATER TEST OF TWELVE FEET OF HEAD, HELD LONG ENOUGH TO VISUALLY INSPECT EACH JOINT. C.TEST ALL LOW PRESSURE STEAM, CONDENSATE, HEATING WATER, CONDENSER WATER, DUAL TEMPERATURE WATER, CHILLED WATER AND REDUCED PRESSURE DOMESTIC WATER PIPING, BEFORE CONNECTING TO UNITS, AT 150 PSIG HYDROSTATIC PRESSURE. D.TEST ALL HIGH PRESSURE STEAM AND CONDENSATE, RADIANT PANEL (EMBEDDED IN CONCRETE), GLYCOL FILLED WATER LINES, FIRE LINES AND DOMESTIC WATER SERVICE LINES TO PRV AT 200 PSIG HYDROSTATIC PRESSURE. E.TEST ALL NATURAL GAS PIPING UNDER 60 PSIG AIR PRESSURE. F.TEST ALL COMPRESSED AIR PIPING UNDER 150 PSIG AIR PRESSURE. G.TEST ALL REFRIGERATION PIPING PER THE CURRENT EDITIONS OF THE INTERNATIONAL BUILDING CODE -CHAPTER 11 AND ASHRAE STANDARD 15 H.SEAL ALL AUDIBLE AND VISIBLE LEAKS IN DUCTWORK. SMOKE TESTING OF DUCTWORK FOR UNDETECTED LEAKS MAY BE REQUIRED BY THE MECHANICAL ENGINEER IF AIR FLOW REQUIREMENTS CANNOT BE MAINTAINED. 3.08 FLUSHING, CLEANING AND STERILIZING A. CLEAN ALL NEWLY INSTALLED OR MODIFIED DIFFUSERS, GRILLES AND DUCTWORK, INCLUDING ELEMENTS REMOVED AND REINSTALLED DURING CONSTRUCTION. B. BEFORE FINAL CONNECTIONS ARE MADE IN THE PIPING SYSTEMS, ALL PIPING EXCEPT AS INDIVIDUALLY NOTED BELOW , SHALL BE BLOWN OUT WITH AIR AND THEN COMPLETELY WASHED OUT WITH CLEANING COMPOUNDS COMPATIBLE WITH FINAL FLUID TO AVOID CONTAMINATION. THE SYSTEMS SHALL THEN BE FLUSHED FOR THE COMPLETE REMOVAL OF ALL FOREIGN MATERIALS. FURNISH ALL TEMPORARY CONNECTIONS, VALVES. ETC., REQUIRED FOR THIS PURPOSE. CHEMICALS USED IN THE PIPE CLEANING AS WELL AS ALL CHEMICALS USED FOR WATER TREATMENT SHALL BE CHEMICALLY COMPATIBLE WITH ALL ELEMENTS OF THE PIPING SYSTEM IN PARTICULAR THE FLANGE GASKET MATERIAL. C. AFTER FLUSHING STERILIZE THE DOMESTIC WATER SYSTEM UN ACCORDANCE WITH AWWA STANDARD C651-86, DISINFECTING WATER MAINS, AND ALL SUBSEQUENT ADDENDA. AFTER MINIMUM CONTACT PERIOD, FLUSH THE SYSTEM WITH CLEAN WATER UNTIL THE RESIDUAL CHLORINE IS NO GREATER THAN THE CITY WATER. SUBMIT TO THE ARCHITECT, WRITTEN CERTIFICATION THAT STERILIZATION HAS BEEN PERFORMED. INCLUDE A COPY IN OPERATION AND MAINTENANCE MANUALS. PROVIDE A TEST ANALYSIS BY THE STATE HEALTH DEPARTMENT OF A RANDOM WATER SAMPLE, IF REQUESTED BY THE ARCHITECT. D. PROVIDE TESTING OF THE DRINKING WATER AT THE MAIN WATER SUPPLY AND ALL OUTLETS TO VERIFY COMPLIANCE WITH EPA REGULATIONS WHICH PROHIBIT THE USE OF SOLDER WHICH CONTAINS LEAD. OBTAIN VIALS FROM THE COLORADO DEPARTMENT OF HEALTH OR OTHER APPROVED TESTING OF LABORATORY. LABEL EACH VIAL WITH THE DATE, TIME, AND LOCATION AND RECORD SAME ON A LOG SHEET. THE JOB SUPERINTENDENT SHALL WITNESS THE SAMPLE TAKING AND SIGN THE LOG AS WELL AS THE CONTRACTOR WHO DRAW S THE SAMPLES. SUBMIT COPIES WITH THE O & M MANUALS. END OF SECTION SECTION 200553 MECHANICAL IDENTIFICATION GENERAL 1.01 DESCRIPTION OF WORK A. FURNISH AND INSTALL a. MARKERS, TAGS AND LABELS FOR MECHANICAL PIPES, DUCTS AND EQUIPMENT. b. PIPE IDENTIFICATION AND FLOW INDICATIONS. c. VALVE TAGS PRODUCTS 2.01 MATERIALS A. PIPE MARKERS: IDENTIFY THE CONTENTS OF THE VARIOUS PIPING SYSTEMS. FLOW ARROWS SHALL CLEARLY INDICATE THE DIRECTION OF FLOW. UTILIZE EITHER OF THE FOLLOWING METHODS: a.PRESSURE SENSITIVE MARKER: BRADLEY TYPE B-350 OR B-946, SENTON, MSI, CRAFTMARK OR EQUIVALENT FLEXIBLE FILM IDENTIFICATION MARKERS AND TAPE, WITH LEGEND SIZE, COLOR CODING, AND MARKER LENGTH PER ANSI A13.1. B.TAGS: ALUMINUM OR BRASS 1 ½”DIAMETER WITH EDGES GROUND SMOOTH AND COLOR CODED TO MATCH PIPING SYSTEM IDENTIFICATION. PUNCH EACH TAG TO RECEIVE TIE WIRES. EVENLY SPACE AND STAMP LETTERS (1/4”HIGH) AND NUMBERS (7/16”HIGH) INTO THE METAL SURFACE, WITH BLACK LETTERS. C.LABELS: WHITE PLASTIC LAMINATE WITH BLACK ENGRAVING, FASTENED WITH BRASS SCREWS. PRESSURE-SENSITIVE EMBOSSED LABELS (DYMO TYPE) ARE NOT ACCEPTABLE. PROVIDE LABELS OF UNIFORM SIZE. LABEL ALL EQUIPMENT UNLESS A MANUFACTURER’S LABEL IS FIRMLY ATTACHED. 2.02 STENCILS A. PRESSURE SENSITIVE MARKERS a. CONFORM TO THE FOLLOWING SCHEDULE: OUTSIDE DIAMETER OF LENGTH OF MINIMUM PIPE OR PIPE INSULATION COLOR FIELD SIZE LETTER 1/2"8"3/8" 3/4"THROUGH 1-1/4"8"1/2" 1-1/2" THROUGH 2"8"3/4" 2-1/2" THROUGH 6"12"1-1/4" DUCTWORK AND EQUIPMENT ----2-1/2" EXECUTION 3.01 PIPING IDENTIFICATION A. GENERAL a. IDENTIFY PIPING IN CRAWLSPACES, ABOVE CEILINGS, ETC. AS WELL AS EXPOSED TO VIEW EXCEPT PIPING IN FINISHED AREAS. PROVIDE IDENTIFYING MARKINGS AT VALVES, FITTINGS, AND EQUIPMENT, AT TERMINAL POINTS, AT EACH BRANCH AND RISER TAKE-OFF, ON PIPES THAT LEAD TO AND FROM UNDERGROUND AREAS, AND AT BOTH SIDES OF PIPING PASSING THROUGH WALLS, CEILINGS, AND FLOORS. IN ADDITION, PROVIDE IDENTIFYING MARKINGS AT 30 FEET O.C. FOR EXPOSED PIPING AND CONCEALED PIPING. b. ALL MARKERS MUST BE IN COMPLIANCE WITH RESPECT TO (1) PROPER LETTER COLOR, (2) PROPER LETTER SIZE, (3) CORRECT BACKGROUND COLOR, AND (4) PROPER MARKER LENGTH. NOTE: COLORS TO MATCH EXISTING OR TO BE SELECTED BY OWNER. c. FOR PIPES UNDER ½”O.D. COLOR CODED IDENTIFICATION TAGS SHALL BE SECURELY FASTENED AT ALL REQUIRED LOCATIONS. TAGS SHALL BE 1 ½”IN DIAMETER. d. IDENTIFICATION OF ALL PIPING SYSTEMS SHALL CONFORM TO THE DESIGNATIONS IN THE MECHANICAL LEGEND ON THE DRAWINGS. e. APPLY DIRECTIONAL FLOW ARROWS ADJACENT TO EACH PIPE MARK. B. PRESSURE SENSITIVE MARKERS APPLY IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS. MARKER ADHESION WILL BE TESTED FOR PERMANENCE. REPLACE ANY MARKERS SHOWING DOG-EARS, BUBBLES OR OTHER FAILINGS. C.MARKERS AND MARKINGS a. USE AN ARROW MARKER WITH EACH PIPE CONTENT MARKER. THE ARROW SHALL ALWAYS POINT AWAY FROM THE PIPE MARKING AND IN THE DIRECTION OF FLOW; COLOR AND HEIGHT OF ARROW TO BE SAME AS CONTENT MARKING. IF FLOW CAN BE IN BOTH DIRECTIONS, USE A DOUBLE-HEADED ARROW. b. APPLY PIPE AND ARROW MARKING WITHIN THREE INCHES OF EACH VALVE TO SHOW PROPER IDENTIFICATION OF PIPE CONTENTS AND DIRECTION OF FLOW. c. APPLY THE MARKING TO THE PIPE SO LETTERING IS IN THE MOST LEGIBLE POSITION. FOR OVERHEAD PIPING, APPLY MAKING ON THE LOWER HALF OF THE PIPE WHERE VIEW IS UNOBSTRUCTED, SO MARKING CAN BE READ FROM FLOOR LEVEL. 3.02 VALVE IDENTIFICATION A. IDENTIFY ALL VALVES AND COCKS INCLUDING FIRE PROTECTION VALVES, IN MAIN AND BRANCH PIPING LOCATED INSIDE THE BUILDING. USE TAGS SECURED WITH BRASS ‘S’HOOKS, BRASS JACK CHAINS OR BEAD CHAINS. B. STAMP VALVE TAGS WITH A UNIQUE PREFIX TO INDICATE SYSTEM, FOLLOWED BY A NUMBER. (EXAMPLE: CW -1; CW -2; HW -1; ETC.). IN GENERAL, THE PREFIX SHALL MATCH THE SYSTEM ABBREVIATION USED ON THE DRAWINGS. C. PROVIDE A TYPEWRITTEN LIST OF VALVES INCLUDING: VALVE IDENTIFICATION NUMBER, LOCATION, FUNCTION, NORMAL POSITION, SERVICE AND AREA SERVED. MOUNT LIST UNDER GLASS AS DIRECTED. INCLUDE ADDITIONAL COPIES IN THE OPERATION AND MAINTENANCE MANUALS. D. SHOW VALVE TAG DESTINATIONS IN THE PROJECT RECORD DOCUMENT DRAWINGS AND ON THE SCHEMATIC FLOW DIAGRAMS. 3.03 EQUIPMENT IDENTIFICATION A. CONTROLS: LABEL MAGNETIC STARTERS AND RELAYS TO IDENTIFY CONNECTING OR CONTROLLED EQUIPMENT. LABEL MANUAL OPERATING SWITCHES,FUSED DISCONNECT SWITCHES AND THERMAL OVERLOAD SWITCHES W HICH HAVE NOT BEEN SPECIFIED AS FURNISHED WITH INDEXED FACEPLATES AS TO CONNECTED OR CONTROLLED EQUIPMENT. LABEL AUTOMATIC CONTROLS, CONTROL PANELS, ZONE VALVES, PRESSURE/ELECTRIC AND ELECTRIC/PRESSURE SWITCHES. B. PUMPS: ALL PUMPS SHALL BE IDENTIFIED AS TO SERVICE AND ZONE(S) SERVED. LABEL BASE MOUNTED PUMPS. TAGS SECURED BY TIE WIRE MAY BE USED ON SMALL IN-LINE PUMPS. C. STORAGE TANKS AND WATER HEATERS: LABEL TANKS AS TO SERVICE. IDENTIFY THE CONNECTING PIPES TO EACH TANK. D. FANS: LABEL SUPPLY AND EXHAUST FANS AND AIR HANDLING UNITS AND CONNECTING DUCTWORK SUPPLYING ONE OR MORE AREAS FROM AN EQUIPMENT ROOM OR ISOLATED CRAWL OR FURRED SPACE AS TO DRAWING CODE NUMBER, SERVICE AND AREAS OF ZONES SERVED. E. AIR CONDITIONING EQUIPMENT: IDENTIFY AIR CONDITIONING EQUIPMENT SUCH AS REFRIGERATION UNITS, HEAT EXCHANGERS, COOLING TOWERS,PUMPS, ETC. BY SYSTEM NAMEPLATES. WHEN MORE THAN ONE PIECE OF LIKE EQUIPMENT IS INSTALLED, THEY SHALL BE IDENTIFIED AS TO AREA OF SPACE SERVED. F. FIRE DAMPERS: a. IDENTIFY ALL FIRE DAMPERS AND THEIR ACCESS DOORS BY MARKERS SECURED TO THE ACCESS DOOR. b. PROVIDE AN IDENTIFYING LABEL OR MARK, VISIBLE FROM THE OCCUPIED SPACE, INDICATING THE LOCATION OF EACH DAMPER OR EQUIPMENT. LABEL SHALL BE CLEAR TAPE WITH BLACK LABELING APPLIED TO THE CEILING GRID T-BARS. END OF SECTION SECTION 200700 INSULATION GENERAL 1.01 SCOPE OF WORK A. PIPING INSULATION, INCLUDING ALL PIPING ACCESSORIES B. EXTERNAL DUCT WRAP 1.02 QUALITY ASSURANCE A. REQUIREMENTS OF REGULATORY AGENCIES a. FLAME/SMOKE RATING. PROVIDE COMPOSITE MECHANICAL INSULATION (INSULATION, JACKETS, COVERINGS, SEALERS, MASTICS AND ADHESIVES)WITH FLAME-SPREAD INDEX OF 25 OR LESS, AND SMOKE DEVELOPED INDEX OF 50 OR LESS AS TESTED BY ASTM E 84 (NFPA 255) METHOD. IN ADDITION, THE PRODUCTS, WHEN TESTED, SHALL NOT DRIP FLAME PARTICLES, AND FLAME SHALL NOT BE PROGRESSIVE. PROVIDE UNDERWRITERS LABORATORIES INC. LABEL OR LISTING (UL 723), OR SATISFACTORY CERTIFIED TEST REPORT FROM AN APPROVED TESTING LABORATORY TO PROVE THAT FIRE HAZARD RATINGS FOR MATERIALS PROPOSED FOR USE TO NOT EXCEED THOSE SPECIFIED. b. EXCEPTIONS: THE FOLLOWING MATERIALS ARE EXCEPTIONS TO THE FLAME/SMOKE RATING REQUIREMENTS SPECIFIED ABOVE: 1. NYLON ANCHORS FOR SECURING INSULATION TO DUCTS AND EQUIPMENT. 2. CORK OR TREATED WOOD INSERTS USED BETWEEN SHIELDS AND PIPING AT HANGERS ON LOW-TEMPERATURE PIPING. 1.03 SUBMITTALS PRODUCT DATA SUBMIT MANUFACTURER’S TECHNICAL DATA FOR EACH TYPE OF MECHANICAL INSULATION IN ACCORDANCE WITH SECTION 200500. SUBMIT SCHEDULE SHOWING MANUFACTURER’S PRODUCE NUMBER, K-VALUE, THICKNESS AND FURNISHED ACCESSORIES FOR EACH MECHANICAL SYSTEM REQUIRING INSULATION 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 12" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/25/2024 1:48:13 PM 1/25/2024 1:48:13 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt M001 01/24/2024 23289 MECHANICAL SPECIFICATIONS KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 11/08/2024 PRODUCTS 2.01 ACCEPTABLE MANUFACTURERS OWENS CORNING, JOHNS MANVILLE, CERTAINEED MASON, KNAUF, ARMSTRONG AND IMCOA INSULATION WILL BE CONSIDERED EQUIVALENT AND WILL BE ACCEPTABLE WITHOUT PRIOR APPROVAL BY THE CONSULTING MECHANICAL ENGINEER. 2.02 ACCEPTABLE PRODUCTS VARIOUS CODES ARE MORE RESTRICTIVE ON THE USE OF CERTAIN PRODUCTS IN PLENUMS, ETC. THIS SPECIFICATION ALLOWS SEVERAL METHODS OF INSULATING VALVES, FITTINGS, ETC., BUT IT IS THE CONTRACTOR’S AND THE MANUFACTURER’S RESPONSIBILITY TO ASSURE THAT THE CODE AUTHORITIES WILL APPROVE ANY PRODUCT TO BE INSTALLED ON THE PROJECT. 2.03 MATERIALS A. PIPE INSULATION –INTERIOR USE a. FIBERGLASS: ONE-PIECE MOLDED THREE POUND FIBERGLASS PIPE INSULATION (ASTM C 547, CLASS 2) WITH FACTORY APPLIED ALL-SERVICE JACKET WITH SELF-SEALING LAP. JACKET COLOR SHALL BE WHITE AND SUITABLE FOR PAINTING WITH LATEX PAINTS. INSULATION SHALL BE SUITABLE FOR PIPE TEMPERATURES FROM 0°F TO 850°F. MAXIMUM K- VALUE SHALL BE 0.24 BTU-IN/HR-SQ FT/DEGREES AT 75°F MEAN TEMPERATURE (ASTM C335). JACKET SHALL PROVIDE A VAPOR BARRIER WITH A PERMEANCE OF LESS THAN 0.02 PERMS/IN (AS TESTED BY PROCEDURE A OF ASTM E96). FIRE SAFETY SHALL COMPLY WITH ASTM E84, UL 723 AND NFPA 255. B. PIPE INSULATION –EXTERIOR USE a. FIBERGLASS: FIBERGLASS PIPE INSULATION FOR EXTERIOR USE SHALL BE THE SAME AS FOR INTERIOR USE, EXCEPT THAT THE ALL-SERVICE JACKET MAY BE OMITTED WHERE A VAPOR BARRIER IS NOT REQUIRED AND REPLACED WITH A FACTORY INSTALLED ALL-WEATHER 30 MIL UV RESISTANT PVC JACKET OR A METAL JACKET INSTALLED ACCORDING TO PART 3 OF THIS SPECIFICATION. 2.04 PIPING ACCESSORIES (FITTINGS, UNIONS, ETC.) INSULATION A. PRE-MOLDED INSULATION SECTIONS: PRE-MOLDED INSULATION SECTIONS SHALL MEET THE REQUIREMENTS FOR THE ADJACENT INSULATION. B. TAPE: PROVIDE TAPE WITH PRESSURE SENSITIVE ADHESIVE SUITABLE FOR SEALING ALL SERVICE JACKETS ON CHILLED AND DUAL TEMPERATURE PIPING SYSTEM. TAPE SHALL PROVIDE A VAPOR BARRIER. C. PVC SEALING TAPE: PROVIDE PVC SEALING TAPE WITH PRESSURE SENSITIVE ADHESIVE SUITABLE FOR USE WITH PRE-MOLDED PVC INSULATION COVERS. TAPE SHALL PROVIDE A VAPOR BARRIER. TAPE SHALL BE WHITE AND 10 MIL THICK. D. VAPOR BARRIER MASTIC: MASTIC SHALL BE A WATER-BASE PRODUCT SUITABLE FOR SPRAYING OR TROWEL APPLICATION. COLOR SHALL BE WHITE. WATER VAPOR PERMEANCE (ASTM E 398) SHALL BE 3.0 PERMS AT 1/16 IN. DRY FILM THICKNESS NEW AND 1.0 PERM WHEN AGED. SURFACE TEMPERATURE RANGE SHALL BE -20°F TO 200°F. E. PVC JACKETING AND FITTING COVERS: PVC COVERS SHALL BE USED WITH FIBERGLASSINSERTS OR WITH FIBERGLASS PIPE INSULATION CUT TO THE SHAPE OF THE COVER. INSERTS SHALL MEET THE TEMPERATURE REQUIREMENTS FOR FIBERGLASS PIPE INSULATION. COVERS AND JACKETING SHALL MEET THE 25/50 LAME AND SMOKE DEVELOPED RATINGS OF ASTM E 84. COVERS AND JACKETING SHALL BE WHITE, 20 MIL THICKNESS AND BE SUITABLE FOR SURFACE TEMPERATURES OF UP TO 150° F. COVERS AND JACKETING USED EXTERNAL TO BUILDING SHALL BE 30 MIL THICKNESSES. F. VAPOR BARRIER COATING: PROVIDE WHITE, FLEXIBLE, FIRE RESISTIVE VAPOR BARRIER COATING. PERMEANCE SHALL BE 0.05 PERMS AT 0.055 IN. DRY FILM THICKNESS. COATING SHALL BE GOOD FOR TEMPERATURES AT COATING OF 0°F TO 150°F. G.PIPE SUPPORTS: PROVIDE 180 OR 360 DEGREE HIGH DENSITY POLYURETHANE FOAM, WATERPROOFED CALCIUM SILICATE, OR EXPANDED PERLITE INSULATION INSERT WHERE INDIVIDUAL HANGERS ARE USED. PROVIDE SHIELD FOR HIGH DENSITY INSERT. INSERT TO BE SAME THICKNESS AS ADJOINING PIPE INSULATION. 2.05 EQUIPMENT INSULATION A. FIBERGLASS: FOR EQUIPMENT HAVING SURFACE TEMPERATURES BETWEEN 0°F AND 45° F, PROVIDE FIBERGLASS INSULATION BOARD OF BLANKET MEETING ASTM C 612, 3 PCF DENSITY WITH A K-VALUE OF 0.23 BTU-IN/HR SQ FT/DEGREE AT 75°F MEAN TEMPERATURE. SUPPLY WITH ALL SERVICE JACKET IF OTHER COVERING IS NOT SPECIFIED. FOR EQUIPMENT HAVING SURFACE TEMPERATURES BETWEEN 450°F AND 850°F PROVIDE FIBERGLASS INSULATION BOARD SPECIFIED FOR THESE TEMPERATURES. B. CALCIUM SILICATE: CALCIUM SILICATE EQUIPMENT INSULATION SHALL CONFORM TO ASTM C533, TYPE 1 FOR SURFACE TEMPERATURES TO 1200°F MAXIMUM. INSULATION SHALL HAVE A K-VALUE OF 0.49 BTU-IN/HR-SQ FT/DEGREE AT 400° F MEAN TEMPERATURE. INSULATION SHALL BE ASBESTOS FREE AND BE COLORED BY MANUFACTURER TO BE DESIGNATED ASBESTOS FREE. 2.06 FIBERGLASS DUCT WRAP A. EXPOSED DUCT a. RECTANGULAR DUCT: FIBERGLASS INSULATION BOARD, 1 ½”THICK, 0.6 PCF DENSITY HAVING AN INSTALLED K-VALUE OF 0.23 BTU-IN/HR-SQ FT/DEGREE AT 75°F MEAN TEMPERATURE. SUPPLY WITH VAPOR BARRIER FOIL-SCRIM-KRAFT (FSK) JACKET. FLAME-SPREAD/SMOKE DEVELOPED INDICES SHALL BE 25/50 OR LESS. b. ROUND DUCT: FIBERGLASS DUCT WRAP CONFORMING TO ASTM C 553, TYPE 1, 1 ½”THICK, 0.75 PCF DENSITY HAVING A K-VALUE OF 0.27 BTU-IN/HR-SQ FT/DEGREE AT 75°F MEAN TEMPERATURE. SUPPLY WITH FOIL-SCRIM-KRAFT (FSK) JACKET. FLAM-SPREAD/SMOKE DEVELOPED INDICES SHALL BE 25/50 OR LESS. B. CONCEALED DUCT: FIBERGLASS DUCT WRAP CONFORMING TO ASTM, C 553, TYPE 1, 1 ½”THICK, 1 PCF DENSITY, HAVING A K-VALUE OF 0.27 BTU-IN/HR-SQ FT/DEGREE AT 75°F MEAN TEMPERATURE. SUPPLY WITH FOIL-SCRIM-KRAFT (FSK) JACKET. FLAME-SPREAD/SMOKE DEVELOPED INDICES SHALL BE 25/50 OR LESS. 2.07 INSULATION ACCESSORIES A. GENERAL: PROVIDE INSULATION ACCESSORIES COMPATIBLE WITH MATERIALS TO WHICH APPLIED AND SUITABLE FOR THE SERVICES. PROVIDE INSULATION ACCESSORIES THAT DO NOT CORRODE, SOFTEN OR OTHERWISE ATTACH THE INSULATION OR JACKET IN EITHER THE WET OR DRY STATE. EXECUTION 3.01 GENERAL INSTALLATION REQUIREMENTS A. WORKMANSHIP a. INSULATION SHALL BE APPLIED BY EXPERIENCED COVERERS PER BEST TRADE PRACTICE AND MANUFACTURER’S PRINTED INSTALLATION INSTRUCTIONS. INSULATION SHALL BE CLEAN AND DRY WHEN INSTALLED. INSTALL INSULATION MATERIAL WITH SMOOTH AND EVEN SURFACES. BUTT EDGES FIRMLY TOGETHER. b. MAKE INSULATION CONTINUOUS THROUGH SLEEVES OR OPENINGS IN WALLS AND FLOORS, EXCEPT WHEN THERE IS A REQUIRED FIRE RESISTANCE RATING. WHERE THIS OCCURS, FILL THE OPEN SPACE BETWEEN THE PIPE OR DUCT AND THE BUILDING OPENING WITH FIRE STOP SEALANT. CARRY INSULATION THROUGH HANGERS, INCLUDING TRAPEZE HANGERS. BUTT INSULATION TIGHT TO HIGH DENSITY INSERTS. 3.02 PIPE INSULATION INSTALLATION A. GENERAL: INSTALL PIPE INSULATION OF AT LEAST THE MINIMUM THICKNESS SPECIFIED IN TABLE 200700-1. B. DOMESTIC COLD WATER PIPING a. UNLESS OTHERWISE SPECIFIED, INSULATE ALL DOMESTIC COLD WATER PIPING. b. A VAPOR BARRIER SHALL BE PROVIDED ON ALL INSULATED SURFACES OF THE PIPING SYSTEM. C. CONDENSATE PIPING a. INSULATE CONDENSATE DRAIN PAN PIPING AND FITTINGS, THE SAME AS FOR DOMESTIC COLD WATER PIPING, TO PROVIDE VAPOR BARRIER INSTALLATION. D. HEATING HOT WATER PIPING a. UNLESS OTHERWISE SPECIFIED, INSULATE ALL HEATING HOT WATER AND STEAM PIPING. THIS INCLUDES CONDENSATE PIPING AND BOILER FEED PIPING. b. NO VAPOR BARRIER IS REQUIRED. E. CHILLED WATER, CONDENSER WATER AND DUAL TEMPERATURE PIPING a. UNLESS OTHERWISE SPECIFIED, INSULATE ALL CHILLED WATER PIPING. b. A VAPOR BARRIER SHALL BE PROVIDED AT ALL INSULATED SURFACES. F. VALVES, FLANGES, UNIONS, FITTINGS, AIR SEPARATORS AND PUMP CASINGS a. INSULATE VALVES, FLANGES, UNIONS, AND FITTINGS IN ALL TYPES OF SYSTEMS, AIR SEPARATORS IN HEATING AND CHILLED/DUAL TEMPERATURE WATER SYSTEMS, AND PUMP CASING FOR CHILLED AND DUAL TEMPERATURE WATER SYSTEMS AS FOLLOWS: 1. OPTION 1: INSULATE WITH PRE-MOLDED INSULATION SECTIONS. SECURE SECTIONS IN PLACE WITH ALL SERVICE JACKET TAPE AND TRIM INSULATION TO ASSURE AN EVEN TRANSITION WITH ADJACENT PIPE INSULATION. APPLY GLASS CLOTH CIRCUMFERENTIALLY AROUND INSULATION SECTIONS AND THEN APPLY VAPOR BARRIER MASTIC OVER THE ENTIRE SURFACE TO PROVIDE A VAPOR SEAL. 2. OPTION 2: INSULATE WITH FACTORY PRECUT, TWO LAYER INSULATION AND COVER WITH FACTORY PRE-MOLDED, ONE PIECE PVC FITTING COVERS. TUCK THE ENDS OF THE INSULATION SNUGLY INTO THE THROAT OF THE FITTING COVERS. SECURE THE FITTING COVER WITH VAPOR BARRIER MASTIC OR BY TAPING THE ENDS CIRCUMFERENTIALLY WITH PVC SEALING TAPE TO THE ADJACENT PIPE COVERING. TAPE SHALL OVERLAP AT LEAST ¼”AND EXTEND A MINIMUM OF 2”ONTO THE PIPE COVERING. G.PIPING WITH HEAT TRACING INSULATE ALL PIPING WITH HEATING TRACING WITH A MINIMUM OF ½”INSULATION OR THE SAME AS FOR THE TYPE OF SYSTEM CONNECTED TO. INSULATION SHALL BE ONE SIZE LARGER THAN PIPE SIZE TO ALLOW FOR HEAT TRACING. H.EXTERIOR PIPING a. GENERAL 1. ALL INSULATED PIPING WHICH IS “OUTDOORS”OR EXPOSED TO WEATHER SHALL BE PROVIDED WITH A SUITABLE JACKET OR COATING. JACKETS MAY BE PROVIDED AS PART OF THE INSULATION SYSTEM IF SPECIFIED FOR EXTERIOR USE BY THE MANUFACTURER. INSTALLATION TO BE PER MANUFACTURER’S RECOMMENDATIONS. 2. INSULATION SHALL BE CARRIED THROUGH BUILDING WALL AND TERMINATED WITH SEALED ENDS INSIDE BUILDING OR CONTINUED AS REQUIRED. b. METAL JACKET INSTALLATION 1. JACKETS SHALL BE INSTALLED WITH METAL BANDS SECURING THE JACKET IN PLACE. BANDS SHALL BE LOCATED AT BUTT JOINT OVERLAPS AND SPACED BETWEEN BUTT JOINTS. 2. OVERLAPS IN THE JACKET SHALL BE POSITIONED TO SHED WATER. BUTT JOINT OVERLAPS SHALL BE WIDE ENOUGH TO PROVIDE WEATHERPROOFING. 3. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS. I.MINIMUM PIPE INSULATION A. THE MINIMUM PIPE INSULATION REQUIREMENTS ARE NOTED IN THE INSULATION SCHEDULES ON SHEET M-620. 3.03 DUCT INSULATION INSTALLATION A. OUTSIDE DUCT WRAP a. GENERAL 1. EXAMINE ALL EXISTING TO REMAIN DUCTWORK IN THE PROJECT AREA. PATCH AND SEAL ALL DUCT OPENINGS AND VISIBLE OR AUDIBLE LEAKS. REPAIR DUCT INSULATION SO THAT IT IS CONTINUOUS. 2. SUPPLY AND/OR RETURN DUCTWORK LOCATED WITHIN CONDITIONED SPACES SERVED BY THIS DUCTWORK, DO NOT REQUIRE INSULATION. DUCTWORK PASSING THROUGH A SPACE THAT IS NOT SUPPLIED AIR BY THIS DUCTWORK REQUIRES INSULATION. MECHANICAL ROOMS AND CEILING PLENUMS ARE NOT CONDITIONED SPACES AND DUCT INSULATION IS REQUIRED. 3. INSULATION FOR EXPOSED RECTANGULAR DUCTS SHALL BE FIBERGLASS BOARD. INSULATION FOR OTHER DUCTS SHALL BE FIBERGLASS DUCT WRAP. 4. DUCTS FOR OUTSIDE AIR INTAKES OR DUCTS EXPOSED TO THE WEATHER SHALL HAVE 2”THICK INSULATION. B. EXTERIOR DUCTWORK a. GENERAL 1. ALL EXTERNALLY INSULATED DUCTWORK WHICH IS “OUTDOORS”OR EXPOSED TO WEATHER SHALL BE PROVIDED WITH AN ALUMINUM OR OTHER PRE-APPROVED SUITABLE JACKET. JACKETS MAY BE PROVIDED AS PART OF THE INSULATION SYSTEM IF SPECIFIED FOR EXTERIOR USE BY THE MANUFACTURER. INSTALLATION TO BE PER MANUFACTURER’S RECOMMENDATIONS. 2. INSULATION SHALL BE CARRIED THROUGH BUILDING WALL AND TERMINATED WITH SEALED ENDS INSIDE BUILDING OR CONTINUED AS REQUIRED. C.ALUMINUM JACKET INSTALLATION a. JACKETS SHALL BE INSTALLED WITH METAL BANDS SECURING THE JACKET IN PLACE. BANDS SHALL BE LOCATED AT BUTT JOINT OVERLAPS AND SPACED BETWEEN BUTT JOINTS. b. OVERLAPS IN THE JACKET SHALL BE POSITION TO SHED WATER. BUTT JOINT OVERLAPS SHALL BE WIDE ENOUGH TO PROVIDE WEATHERPROOFING. c. WEATHERPROOF ALL OVERLAPS AND JOINTS. d. ALL JACKET CUTOUTS FOR DUCTWORK SUPPORTS SHALL BE SEALED WATER TIGHT. e. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS. END OF SECTION SECTION 211313 FIRE PROTECTION AND SPRINKLER SYSTEMS GENERAL 1.01 RELATED DOCUMENTS THE GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTAL CONDITIONS AND DIVISION 1-SPECIFICATION SECTIONS AND CONTRACT DOCUMENTS APPLY TO WORK IN THIS SECTION. CONSULT THEM FOR FURTHER INSTRUCTIONS AND BE GOVERNED BY THE REQUIREMENTS THERE UNDER. 1.02 DESCRIPTION A.WORK INCLUDED a. FURNISH ALL LABOR AND MATERIAL, AND PERFORM ALL OPERATIONS NECESSARY FOR THE INSTALLATION OF COMPLETE AND OPERATING SYSTEMS SUBJECT TO THE CONDITIONS OF THE CONTRACT. THE WORK ALL MUST BE DONE IN ACCORDANCE WITH THE APPLICABLE NFPA STANDARDS AND COMPLYING WITH THE REQUIREMENTS OF LOCAL BUILDING AND FIRE DEPARTMENTS. THESE JURISDICTIONAL AUTHORITIES AND CODES SHALL TAKE PRECEDENCE OVER THE DRAWINGS AND SPECIFICATIONS, IN THE EVENT OF DISPUTE OR DISCREPANCY BETWEEN REQUIREMENTS OF CONTRACT DOCUMENTS AND INSURANCE RATING AUTHORITY OR CODE. b.FEES AND PERMITS: ALL FEES AND PERMITS SPECIFICALLY REQUIRED FOR FIRE PROTECTION WORK, OTHER THAN PERMITS NORMALLY REQUIRED BY THE MECHANICAL SUBCONTRACTOR, SHALL BE APPLIED FOR AND PAID FOR BY THE FIRE PROTECTION SUBCONTRACTOR. 1.03 QUALITY ASSURANCE CONTRACTOR QUALIFICATIONS WORK SHALL BE PERFORMED BY A CONTRACTOR REGULARLY ENGAGED IN THE DESIGN AND INSTALLATION OF FIRE PROTECTION SYSTEMS IN ACCORDANCE WITH NFPA REQUIREMENTS HAVING AT LEAST 5 YEARS CONTINUOUS EXPERIENCE IN THE WORK SPECIFIED. 1.04 REGULATORY AND CODE REQUIREMENTS APPLICABLE CODES AND STANDARDS INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: A.NFPA 13-INSTALLATION OF SPRINKLER SYSTEMS, THE DENVER BUILDING CODE AMENDMENTS, INTERNATIONAL BUILDING AND FIRE CODE. 1.05 SUBMITTALS A.SHOP DRAWINGS: SUBMIT FOR THE FOLLOWING IN ACCORDANCE WITH SECTION 200500 AND DIVISION 1. a.SUBMIT FINAL SHOP DRAWINGS SHOWING HEAD LOCATIONS AND PIPING ROUTES. (SHOW ADDITIONAL HEADS NOT INDICATED ON REFLECTED CEILING PLANS BUT ARE REQUIRED FOR PROPER COVERAGE.) PROVIDE DRAWINGS WHICH ENCOMPASS A COMPLETE AND CODE COMPLIANT DESIGN UTILIZING STANDARDS OUTLINED ABOVE AS A MINIMUM. DRAWINGS SHALL BEAR REVIEW STAMP OF LOCAL JURISDICTIONAL CODE AUTHORITIES. INCLUDE HYDRAULIC CALCULATIONS. NO WORK SHALL BE STARTED UNTIL ALL APPROVALS ARE OBTAINED. b.DRAWING SUBMITTALS SHALL BE THE SAME SIZE DRAWING FORMAT AND MEDIA AS THE CONSTRUCTION DOCUMENT DRAWINGS. c.THE SHOP DRAWING SUBMITTAL SHALL BE PREPARED BY A PROFESSIONAL FIRE PROTECTION ENGINEER OR A TECHNICIAN WITH A CERTIFICATION OF NICET LEVEL III OR HIGHER. THE SHOP DRAWING SUBMITTAL SHALL BEAR THE STAMP OF THE PROFESSIONAL ENGINEER OR NICET CERTIFIED TECHNICIAN. B.PRODUCT DATA: SUBMIT FOR THE FOLLOWING IN ACCORDANCE WITH SECTION 200500 AND DIVISION 1. ALL VALVES, SPRINKLER DEVICES AND HEADS, PIPE AND FITTINGS, HANGERS, FLOW SWITCHES, SPECIALTIES AND ACCESSORIES USED IN THE SYSTEM. C.TEST REPORTS: SUBMIT CERTIFIED TEST REPORTS IN ACCORDANCE WITH SECTION 200510. D.OPERATION AND MAINTENANCE DATA: SUBMIT IN ACCORDANCE WITH SECTION 200500 AND THE ARCHITECTURAL DIVISION. 1.06 PROJECT CONDITIONS A.EXISTING CONDITIONS: EXAMINE EXISTING CONDITIONS AT THE JOB SITE PRIOR TO ANY PREFABRICATION OF PIPING. MODIFY SYSTEM AS REQUIRED TO COMPLY WITH ACTUAL JOB CONDITIONS AND WORK OF ADJACENT TRADES. B.SEQUENCING AND SCHEDULING: COORDINATE MATERIAL DELIVERY AND INSTALLATION WITH WORK OF OTHER TRADES. 1.07 WARRANTY COMPLY WITH SECTION 200500. 1 YEAR WARRANTY. 1.08 PROJECT RECORD DRAWINGS COMPLY WITH SECTION 200500. 1.09 WATER DAMAGE THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE WORK OF OTHERS, TO THE BUILDING AND PROPERTIES/MATERIALS OF OTHERS CAUSED BY LEAKS IN THE SPRINKLER SYSTEM AND SHALL PAY FOR NECESSARY REPLACEMENT OR REPAIR OF WORK OR ITEMS SO DAMAGED DURING THE INSTALLATION AND TESTING PERIOD OF THIS WORK. PRODUCTS 2.01 GENERAL ALL MATERIAL SHALL BE U.L. LISTED. 2.02 PIPING AND FITTINGS INSIDE THE BUILDING A.PIPING MATERIALS SHALL BE NEW AND DESIGNED FOR 175 PSI WORKING PRESSURE, CONFORMING TO ASTM SPECIFICATIONS. PIPING SHALL HAVE THE MANUFACTURER’S NAME OR BRAND, ALONG WITH THE APPLICABLE ASTM STANDARD MARKED ON EACH PIPE. a.SCHEDULE 40, BLACK STEEL PIPE, ASTM A-135/A-795 AND A53 JOINED BY SCREWED JOINTS (ANSI/ASME B2.1), WELDED JOINTS (ANSI/ASME B31.1) OR BY MECHANICAL GROOVED COUPLINGS OR PUSH-ON (LOCKING) COUPLINGS, JOINED BY UL APPROVED COMBINATION OF COUPLINGS, GASKETS AND GROOVES WHERE APPROVED BY LOCAL JURISDICTION CODE AUTHORITY. GROOVES SHALL BE ROLLED (CUT GROOVES ARE NOT ACCEPTABLE) AND SHALL BE DIMENSIONALLY COMPATIBLE WITH THE COUPLING. B.FITTINGS SHALL BE ABLE TO WITHSTAND THE WORKING PRESSURES INVOLVED BUT NOT LESS THAN 175 PSI COLD WATER. 2.03 SPRINKLER HEADS A.UL LISTED STANDARD SPRAY SPRINKLER HEADS, ORDINARY TEMPERATURE RATINGS (165°F) EXCEPT WHERE HIGH TEMPERATURE HEADS ARE REQUIRED. B.HEADS TO BE PROVIDED AS FOLLOWS: a.HEADS IN TYPICAL FINISHED AREAS: CHROME WITH CHROME ESCUTCHEONS. b.HEADS IN UNFINISHED AREAS: FULLY RECESSED AND CONCEALED HEADS. C.ESCUTCHEONS PROVIDE ESCUTCHEONS TO BE COMPATIBLE WITH SPRINKLER HEADS WHERE NECESSARY. D.ALL HEADS SHALL BE COLOR CODED AND INSTALLED IN COMPLIANCE WITH NFPA 13. EXECUTION 3.01 SERVICE MODIFY THE EXISTING SPRINKLER SYSTEM SERVING THE EXISTING SUITE. PROVIDE NEW PIPING AND HEADS WHERE REQUIRED. 3.02 DISCHARGE OF WATER A.DISCHARGES OF WATER INCLUDE: a.DISCHARGE TO SURFACE WATER OR THE GROUND. b.DISCHARGE TO STORM SEWER. c.DISCHARGE TO ANY CONVEYANCE THAT MAY EVENTUALLY DISCHARGE INTO SURFACE WATER OR TO THE GROUND. d.DISCHARGES TO SANITARY SEWER. B.DISCHARGES FROM FIRE SAFETY MAINTENANCE ACTIVITIES INCLUDE BUT ARE NOT LIMITED TO: a.FLUSHING OR CLEANING OF FIRE SAFETY SYSTEMS. b.DRAINING OF SYSTEMS FOR REPAIRS OR MODIFICATIONS. c.INSPECTOR TESTING. C.PERMITTING: a.DISCHARGES FROM FIRE SAFETY MAINTENANCE ACTIVITIES MUST COMPLY WITH ALL LOCAL AND STATE AUTHORITIES HAVING JURISDICTION (AHJ), INCLUDING BUT NOT LIMITED TO: 1.WATER QUALITY AUTHORITIES 2.WASTE WATER AUTHORITIES b.COMPLY WITH THE REQUIREMENTS OF THE APPROPRIATE AHJ. c.APPLY FOR ANY REQUIRED PERMITS IN A TIMELY MANNER AS TO NOT IMPACT THE CONSTRUCTION SCHEDULE. d.PAY FOR ANY APPLICABLE PERMITS. 3.02 INSTALLATION A.PIPING SHALL BE INSTALLED IN THE MOST DIRECT, STRAIGHT AND MECHANICAL MANNER AS POSSIBLE AND AS CLOSE TO WALLS AND CEILINGS AS IS CONSISTENT WITH GOOD WORKMANSHIP. ALL LINES SHALL BE RUN HIGH ENOUGH TO PERMIT RELOCATION OF LIGHTS WITHOUT MOVING CEILING GRID. B.INSTALL HORIZONTAL PIPING GRADED TO LOW POINTS AND IN A MANNER TO MAKE IT POSSIBLE TO TEST AND EMPTY ENTIRE SYSTEM. PROVIDE VALVES AT LOW POINTS TO FACILITATE SYSTEM DRAINAGE. 3.03 SPRINKLER HEADS ALL HEADS SHALL BE CENTERED IN CEILING TILE WHERE CEILINGS OCCUR, SHOW ACTUAL LOCATION IN SHOP DRAWINGS. 3.04 HYDRAULIC CALCULATIONS A.GENERAL THE FIRE PROTECTION CONTRACTOR SHALL PREPARE HYDRAULIC CALCULATIONS FOR THE DESIGN OF THE SYSTEM AND SUBMIT TO LOCAL JURISDICTION CODE AUTHORITY FOR APPROVAL BEFORE ANY FABRICATION OR INSTALLED IS STARTED. B.FLOW TEST DATA FLOW TESTS SHALL BE PERFORMED BY THIS CONTRACTOR AND VERIFIED BY LOCAL FIRE DEPARTMENT. 3.05 TESTING COMPLY WITH SECTION 200510 AND NFPA 25. 3.06 COMPLETION THIS SUBCONTRACTOR SHALL CALL FOR INSPECTION AND OBTAIN CERTIFICATE OF COMPLETION AND TEST FROM THE FIRE INSPECTION BUREAU UNDER WHOSE JURISDICTION THIS INSTALLATION OCCURS. AFTER THE SYSTEM HAS BEEN INSPECTED AND TESTED PROVIDE AND SIGN A CERTIFICATE, “CONTRACTOR’S MATERIAL AND TEST CERTIFICATES”. CERTIFICATE SHALL ALSO BE SIGNED BY A REPRESENTATIVE OF THE FIRE INSPECTION BUREAU. SUFFICIENT COPIES SHALL BE PREPARED TO ENSURE THAT INSPECTING AUTHORITIES AND THE CONTRACTOR WILL HAVE A COPY FOR THEIR FILES. ALSO PROVIDE A COPY OF NFPA 25, INSPECTION, TESTING AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS FOR EACH O & M MANUAL. END OF SECTION SECTION 226313 MEDICAL GAS PIPING SYSTEMS GENERAL 1.01 WORK INCLUDED A. PIPING PERFORMANCE OF MEDICAL GAS SYSTEMS INCLUDING OXYGEN (O2), NITROUS OXIDE (N2O), MEDICAL AIR (MA), NITROGEN (N2) AND MEDICAL VACUUM SYSTEMS (VAC). B. OUTLETS, VALVES BOXES, VALVES, AND MISCELLANEOUS ACCESSORIES FOR COMPLETE SYSTEMS. C. CERTIFICATION. 1.02 QUALITY ASSURANCE A. COMPLY WITH CURRENT NFPA 99 STANDARDS FOR PRESSURE GASES, AND CGA P-2.1 RECOMMENDATIONS FOR VACUUM SYSTEMS, PLUS APPLICABLE LOCAL, STATE, AND FEDERAL CODES. B. EMPLOY ONLY QUALIFIED JOURNEYMEN FOR THIS WORK. EMPLOY A QUALIFIED MECHANIC WITH A MINIMUM OF 5 YEARS EXPERIENCE IN THE INSTALLATION OF THESE SYSTEMS TO SUPERVISE THE WORK. PRODUCTS 2.01 PIPING –ALL SYSTEMS A. ALL PIPING SHALL BE HARD-DRAWN SEAMLESS MEDICAL GAS TUBE, TYPE L OR K (ASTM B-819) AND BEAR ONE OF THE FOLLOWING MARKINGS: OXY, MED, OXY/MED, ACR/OXY OR ACR/MED. B. ALL PIPING SHALL BE AS SPECIFIC FOR OXYGEN SERVICES; FACTORY WASHED, DEGREASED, AND CAPPED PER NFPA 99. 2.02 MEDICAL GAS VALVING A. VALVES a. ALL VALVES SHALL BE SPECIFICALLY PREPARED FOR OXYGEN SERVICE AND SHALL CONFORM IN ALL PARTICULARS TO NFPA 99 AND SHALL BE CLEANED, ASSEMBLED AND TESTED IN CONFORMANCE WITH THE COMPRESSED GAS ASSOCIATION SPECIFICATION CGA G-41. VALVES 2”AND SMALLER SHALL BE BALL-TYPE, WITH TEFLON SEATS AND ADJUSTABLE STEM PACKING GLAND WITH TEFLON STEM SEAL. VALVES 2 ½”TO 3”SHALL HAVE TEFLON SEATS AND DOUBLE TEFLON STEM SEAL. VALVES 4”AND LARGER SHALL HAVE BUNA-N BALL SEATS. b. ALL BALL VALVES SHALL BE RATED AT 400 PSIG AND ACTUATE FROM FULL “ON”TO FULL "OFF”BY 90 DEGREE TURN OF VINYL GRIPPED VALVE HANDLE. FACTORY INSTALLED COPPER TUBING SHALL BE EXTENDED SUFFICIENTLY TO HELP PREVENT VALVE SEAT DAMAGE DURING SOLDERING. c. UNLESS SPECIFICALLY NOTED OR OBVIOUSLY REQUIRED, MAIN AND RISER VALVES LOCATED IN OTHER THAN PUBLIC AREAS ARE NOT REQUIRED TO BE INSTALLED IN BOX. d. ALL VALVES ARE TO BE LINE SIZE UNLESS OTHERWISE NOTED. e. ALL VALVES ARE TO HAVE GAUGE PORTS UNLESS OTHERWISE NOTED. 2.03 MEDICAL GAS WALL OUTLET STATIONS (MGO) A. MEDICAL GAS OUTLET STATIONS SHALL BE INTEGRAL TO THE BOOMS. OUTLET TYPE SHALL BE COORDINATED WITH USERS. EXECUTION 3.01 INSTALLATION A. MAKE ALL JOINTS IN THE PIPING, EXCEPT THOSE PERMITTED TO BE APPROVED BRASS FLARED TYPE GAS TUBING FITTINGS, AND THOSE AT VALVES OR AT EQUIPMENT REQUIRING SCREW CONNECTIONS, WITH SILVER BRAZING ALLOY OR SIMILAR HIGH MELTING POINT (AT LEAST 1000°F) BRAZING METALS. THE USE OF FLUX IS PROHIBITED IN ALL INSTANCES, EXCEPT WHEN JOINING COPPER WITH BRASS OR OTHER DISSIMILAR METALS. B. AFTER INSTALLATION OF THE PIPING, BUT BEFORE INSTALLATION OF THE OUTLET VALVES, BLOW LINES CLEAR BY MEANS OF OIL-FREE, DRY AIR, OR NITROGEN. C. ALL BRANCH TAKE-OFFS ARE TO BE TAKEN FROM TOP OF MAIN. D. INSTALL VALVES SO THAT GAUGE PORTS ARE ON THE DOWNSTREAM SIDE OF THE VALVE. 3.02 TESTS AND ADJUSTMENTS A.AFTER INSTALLATION OF THE PIPING AND STATION OUTLET ROUGH-IN ASSEMBLIES (BUT BEFORE INSTALLATION OF FINISHING ASSEMBLIES, ACTUATION SWITCHES, GAUGES, ETC.) EACH SECTION OF THE PIPELINE SYSTEM SHALL BE SUBJECTED TO A MINIMUM TEST PRESSURE OF 150 PSIG (200 PSIG MAXIMUM) BY MEANS OF OIL- FREE DRY AIR OR NITROGEN. THE TEST PRESSURE SHALL BE MAINTAINED UNTIL EACH JOINT HAS BEEN EXAMINED FOR LEAKAGE BY MEANS OF SOAPY WATER OR OTHER EQUALLY EFFECTIVE MEANS OF DETECTION SAFE FOR USE WITH OXYGEN. LEAKS, IF ANY, SHALL BE LOCATED, REPAIRED AND RETESTED. AFTER TESTING OF EACH SYSTEM ABOVE, THE COMPLETELY ASSEMBLED STATION OUTLETS AND ALL OTHER COMPONENTS (SWITCHES, GAUGES, FINISH-ASSEMBLIES, ETC.) SHALL BE INSTALLED AND ALL PIPING SYSTEMS SHALL BE SUBJECTED TO A 24 HOUR STANDING PRESSURE TEST AT 20 PERCENT ABOVE THE NORMAL OPERATING PRESSURE WITH OIL-FREE DRY AIR OR NITROGEN. AFTER THE PIPING SYSTEM IS FILLED WITH TEST GAS, THE SUPPLY VALVE AND ALL OUTLETS SHALL BE CLOSED, AND THE SOURCE OF TEST GAS DISCONNECTED. B.THE SYSTEM SHALL REMAIN LEAK-FREE FOR 24 HOURS. WHEN MAKING THE STANDARD PRESSURE TEST, THE ONLY ALLOWABLE PRESSURE CHANGES DURING THE 24 HOUR TEST PERIOD SHALL BE THOSE CAUSED BY VARIATIONS IN THE AMBIENT TEMPERATURE AROUND THE PIPING SYSTEM. SUCH CHANGES CAN BE CHECKED BY MEANS OF THE PRESSURE-TEMPERATURE RELATIONSHIP: CALCULATED FINAL ABSOLUTE PRESSURE (ABSOLUTE PRESSURE IS GAUGE PRESSURE PLUS 14.7 PSI GAUGE IS CALIBRATED IN “PSI”) EQUALS THE INITIAL ABSOLUTE PRESSURE TIMES THE FINAL ABSOLUTE TEMPERATURE (ABSOLUTE TEMPERATURE IS TEMPERATURE READING PLUS 460°F, IF THERMOMETER IS CALIBRATED IN FAHRENHEIT DEGREES), DIVIDED BY THE INITIAL ABSOLUTE TEMPERATURE. 3.04 CERTIFICATION OF MEDICAL GAS SYSTEM A. START-UP, TESTING AND CERTIFICATION IF THE MEDICAL GAS SYSTEMS SHALL BE CONDUCTED BY AN INDEPENDENT, THIRD-PARTY, FACTORY TRAINED REPRESENTATIVE WITH A MINIMUM OF 5 YEARS EXPERIENCE IN MEDICAL GAS PIPELINE TESTING AND CERTIFICATION. PROOF OF TWO MILLION DOLLARS LIABILITY INSURANCE IS REQUIRED. B. AFTER SUCCESSFUL START-UP OF ALL SYSTEMS AND COMPONENTS, VITAL INFORMATION REGARDING THE PROPER OPERATION OF THE EQUIPMENT SHALL BE MADE A PART OF THE MEDICAL GAS CERTIFICATION AND INCLUDED IN THE O & M MANUALS. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: a. THE MEDICAL GAS VALVES AND ZONE VALVE BOXES. b. THE OUTLETS, NITROGEN CONTROL PANELS, COLUMNS, AND HOSE DROP ASSEMBLIES. C. TESTING SHALL BE IN STRICT ACCORDANCE WITH NFPA 99 AND THE FOLLOWING: D. LEAKS, IF ANY, SHALL BE LOCATED, REPAIRED AND RETESTED. E. THE FOLLOWING ITEMS SHALL BE PERFORMED BY THE CERTIFIER. a. EACH DEDICATED GAS SYSTEM SHALL BE TESTED WITH OIL-FREE, DRY NITROGEN, TO VERIFY THAT THERE ARE NO CROSS-CONNECTIONS TO ANY OTHER SYSTEM. b. THE TESTING OF THE NOMINAL 55 PSIG MEDICAL GAS SYSTEMS (I.E OXYGEN, NITROUS OXIDE, AND MEDICAL AIR), SHOULD BE DONE IN A SEQUENCE AS TO ALLOW THE LEAST CHANCE OF HAZARD IF A CROSS CONNECTION DID OCCUR. c. EACH PIPING SYSTEM SHALL BE PURGED OF CONTAMINANTS BY FLUSHING WITH THE APPROPRIATE SOURCE GAS WHILE UNDER SYSTEM PRESSURE. d. VALVE TEST: VALVES INSTALLED IN EACH MEDICAL GAS PIPING SYSTEM SHALL BE TESTED TO VERIFY PROPER OPERATION AND ROOMS OR AREAS OF CONTROLS. e. FLOW TEST: 1. ALL OUTLETS SHALL BE TESTED FOR FLOW. TESTS SHALL BE PERFORMED WITH THE USE OF OIL-FREE, DRY NITROGEN AS DESCRIBED IN CGA P-9, INERT GASES: ARGON, NITROGEN, AND HELIUM. 2. OXYGEN, NITROUS OXIDE, AND AIR OUTLETS SHALL DELIVER 6.5 SCFM WITH A PRESSURE DROP OF NO MORE THAN 5 PSIG (35 KPA), AND STATIC PRESSURE OF 50 PSIG (349 KPA). 3. NITROGEN OUTLETS SHALL DELIVER 5.0 SCFM WITH A PRESSURE DROP OF NO MORE THAN 5 PSIG AND STATIC PRESSURE OF 160 PSIG (1118 KPA). f. PIPING PURGE TEST: IN ORDER TO REMOVE ANY TRACES OF PARTICULATE MATTER DEPOSITED IN THE PIPELINES AS A RESULT OF CONSTRUCTION, A HEAVY, INTERMITTENT PURGING OF THE PIPELINE SHALL BE DONE. g. PIPING PURITY TEST: FOR EACH POSITIVE-PRESSURE SYSTEM THE PURITY OF THE PIPING SYSTEM SHALL BE VERIFIED. END OF SECTION SECTION 232100 HEAT GENERATION, REFRIGERATION AND LIQUID HEAT TRANSFER GENERAL 1.01 SCOPE OF WORK PIPE AND FITTING MATERIALS, JOINING METHODS, SPECIAL-DUTY VALVES, AND SPECIALTIES FOR HOT-WATER HEATING PIPING AND CONDENSATE-DRAIN PIPING. 1.02 INSTALLER QUALIFICATIONS: A. Steel Support Welding: Qualify processes and operators according to AWS D1.1/D1.1M, "Structural Welding Code -Steel." B. Welding: Qualify processes and operators according to ASME Boiler and Pressure Vessel Code: Section IX. C. Certify that each welder has passed AWS qualification tests for welding processes involved and that certification is current. PRODUCTS 2.01 COPPER TUBE AND FITTINGS A. ALL PIPING SHALL BE TEMPERED COPPER TUBE, TYPE L OR K (ASTM B-88-96) AND BEAR ONE OF THE FOLLOWING MARKINGS: HWS OR HWR. B. ALL FITTINGS SHALL BE WROUGHT COPPER (ASME B16.22). 2.02 VALVES A. ALL VALVES SHALL COMPLY WITH REQUIREMENTS SPECIFIED IN SECION 200510 "BASIC MATERIALS AND METHODS". B. BRONZE, CALIBRATED-ORIFICE, BALANCING VALVES: BRONZE BODY, BALL OR PLUG TYPE WITH CALIBRATED ORIFICE OR VENTURI, BRASS OR STAINLESS STEEL BALL, RESIN PLUG, PTFE SEAT, THREADED OR SOCKETED END CONNECTION, INTEGRAL PRESSURE GAUGE, LEVER HANDLE WITH MEMORY STOPS, MINIMUM RATING OF 125 PSIG AND OPERATING TEMPERATURE OF 250 DEG F. C. AUTOMATIC FLOW-CONTROL VALVES: a. ACCEPTABLE MANUFACTURERS: ITT BELL AND GOSSETT (MODEL B7-12), AMTROL (MODEL 11F) b. BRASS OR FERROUS METAL BODY, BONZE OR BRASS-ALLOY BALL VALVE c. STAINLESS STEEL, TAMPER PROOF, SELF CLEANING, AND REMOVABLE PISTON AND SPRING ASSEMBLY d. MARK WITH ZONE IDENTIFICATION, VALVE NUMBER, AND FLOW RATE e. SAME SIZE AS PIPE IN WHICH INSTALLED. MAINTAIN CONSTANT FLOW, PLUS OR MINUS 5 PERCENT OVER SYSTEM PRESSURE FLUCTUATIONS. MINIMUM CWP RATING: 175 PSIG. EXECUTION 3.01 HOT-WATER HEATING PIPING, ABOVEGROUND, NPS 2 AND SMALLER, SHALL BE ANY OF THE FOLLOWING: TYPE L, DRAWN-TEMPER COPPER TUBING, WROUGHT- COPPER FITTINGS, AND SOLDERED OR BRAZED JOINTS. 3.02 CONDENSATE-DRAIN PIPING: TYPE L, DRAWN-TEMPER COPPER TUBING, WROUGHT-COPPER FITTINGS, AND SOLDERED JOINTS. 3.03 VALVE APPLICATIONS A. INSTALL SHUTOFF-DUTY VALVES AT SUPPLY AND RETURN CONNECTION TO EACH PIECE OF EQUIPMENT, COIL AND HEAT EXCHANGER AND ADDITIONAL LOCATIONS AS SHOWN ON PLANS. B. INSTALL AUTOMATIC FLOW CONTROL VALVES AT EACH BRANCH CONNECTION TO RETURN MAIN. C. INSTALL AUTOMATIC FLOW CONTROL VALVE IN THE RETURN PIPE OF EACH PIECE OF EQUIPMENT, COIL AND HEAT EXCHANGER. CALIBRATED ORIFICE TYPE BALANCING VALVES SHALL BE USED IN LIEU OF AUTOMATIC FLOW CONTROL VALVES WHERE INDICATED ON DRAWINGS. D. 3.04 PIPING INSTALLATION A. INSTALL PIPING IN CONCEALED LOCATIONS, UNLESS OTHERWISE INDICATED AND EXCEPT IN EQUIPMENT ROOMS AND SERVICE AREAS. B. INSTALL PIPING AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONAL RUNS ARE PROHIBITED UNLESS SPECIFICALLY INDICATED OTHERW ISE. C. INSTALL PIPING ABOVE ACCESSIBLE CEILINGS TO ALLOW SUFFICIENT SPACE FOR CEILING PANEL REMOVAL. D. INSTALL PIPING TO PERMIT VALVE SERVICING. E. INSTALL PIPING FREE OF SAGS AND BENDS. F. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. G. INSTALL PIPING TO ALLOW APPLICATION OF INSULATION. H. SELECT SYSTEM COMPONENTS WITH PRESSURE RATING EQUAL TO OR GREATER THAN SYSTEM OPERATING PRESSURE. I. INSTALL GROUPS OF PIPES PARALLEL TO EACH OTHER, SPACED TO PERMIT APPLYING INSULATION AND SERVICING OF VALVES. J. INSTALL BRANCH CONNECTIONS TO MAINS USING TEE FITTINGS IN MAIN PIPE, WITH THE BRANCH CONNECTED TO THE BOTTOM OF THE MAIN PIPE. K. INSTALL UNIONS IN PIPING, NPS 2 AND SMALLER, ADJACENT TO VALVES,AT FINAL CONNECTIONS OF EQUIPMENT, AND ELSEWHERE AS INDICATED. 3.05 TERMINAL EQUIPMENT CONNECTIONS A. SIZES FOR SUPPLY AND RETURN PIPING CONNECTIONS SHALL BE THE SAME AS OR LARGER THAN EQUIPMENT CONNECTIONS. B. INSTALL CONTROL VALVES IN ACCESSIBLE LOCATIONS CLOSE TO CONNECTED EQUIPMENT. C. INSTALL BYPASS PIPING WITH GLOBE VALVE AROUND CONTROL VALVE. IF PARALLEL CONTROL VALVES ARE INSTALLED, ONLY ONE BYPASS IS REQUIRED. D. MINIMUM RUNOUT/CONNECTION SIZE TO BE 3/4 INCH UNLESS OTHERWISE NOTED. 3.06 FIELD QUALITY CONTROL A. PREPARE HYDRONIC PIPING ACCORDING TO ASME B31.9 AND AS FOLLOWS: a. LEAVE JOINTS, INCLUDING WELDS, UNINSULATED AND EXPOSED FOR EXAMINATION DURING TEST. b. ISOLATE EQUIPMENT FROM PIPING. IF A VALVE IS USED TO ISOLATE EQUIPMENT, ITS CLOSURE SHALL BE CAPABLE OF SEALING AGAINST TEST PRESSURE WITHOUT DAMAGE TO VALVE. INSTALL BLINDS IN FLANGED JOINTS TO ISOLATE EQUIPMENT. 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 12" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/25/2024 1:48:14 PM 1/25/2024 1:48:14 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt M002 01/24/2024 23289 MECHANICAL SPECIFICATIONS KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 11/08/2024 B. PERFORM THE FOLLOWING TESTS ON HYDRONIC PIPING: a. USE AMBIENT TEMPERATURE WATER AS A TESTING MEDIUM UNLESS THERE IS RISK OF DAMAGE DUE TO FREEZING. ANOTHER LIQUID THAT IS SAFE FOR WORKERS AND COMPATIBLE WITH PIPING MAY BE USED. b. WHILE FILLING SYSTEM, USE VENTS INSTALLED AT HIGH POINTS OF SYSTEM TO RELEASE AIR. USE DRAINS INSTALLED AT LOW POINTS FOR COMPLETE DRAINING OF TEST LIQUID. c. SUBJECT PIPING SYSTEM TO HYDROSTATIC TEST PRESSURE THAT IS NOT LESS THAN 1.5 TIMES THE SYSTEM`S WORKING PRESSURE. TEST PRESSURE SHALL NOT EXCEED MAXIMUM PRESSURE FOR ANY VESSEL, PUMP, VALVE, OR OTHER COMPONENT IN SYSTEM UNDER TEST. VERIFY THAT STRESS DUE TO PRESSURE AT BOTTOM OF VERTICAL RUNS DOES NOT EXCEED 90 PERCENT OF SPECIFIED MINIMUM YIELD STRENGTH OR 1.7 TIMES "SE" VALUE IN APPENDIX A IN ASME B31.9, "BUILDING SERVICES PIPING." d. AFTER HYDROSTATIC TEST PRESSURE HAS BEEN APPLIED FOR AT LEAST 10 MINUTES, EXAMINE PIPING, JOINTS, AND CONNECTIONS FOR LEAKAGE. ELIMINATE LEAKS BY TIGHTENING, REPAIRING, OR REPLACING COMPONENTS, AND REPEAT HYDROSTATIC TEST UNTIL THERE ARE NO LEAKS. e. PREPARE WRITTEN REPORT OF TESTING. C. PERFORM THE FOLLOWING BEFORE OPERATING THE SYSTEM: a. OPEN MANUAL VALVES FULLY. b. SET TEMPERATURE CONTROLS SO ALL COILS ARE CALLING FOR FULL FLOW. END OF SECTION SECTION 233110 AIR DISTRIBUTION GENERAL 1.01 SCOPE OF WORK DUCTWORK, FLEXIBLE DUCTS, DUCTWORK, ACCESSORIES, GRILLES AND EQUIPMENT PRODUCTS 2.01 DUCT SEALANT: NON-HARDENING, WATER RESISTANT, NON-COMBUSTIBLE, LIQUID OR MASTIC OR WITH TAPE AS RECOMMENDED BY MANUFACTURER. ALL SEALANTS SHALL HAVE APPROVED FIRE RATING FOR PLENUM APPLICATION AS REQUIRED BY CODE AUTHORITY. 2.02 MATERIALS & EQUIPMENT A. GENERAL a. SIZES SHOWN ON THE DRAWINGS ARE OUTSIDE (SHEET METAL) DUCT DIMENSIONS. DUCTWORK SHALL BE SHEET-METAL, FURNISHED AND INSTALLED IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS OR UNIFORM MECHANICAL CODE, WHICHEVER IS MORE STRINGENT. b. DUCTWORK MATERIALS: ALL DUCTWORK IS TO BE ASTM A525 AND AASTM A527 GALVANIZED STEEL, LOCK FORMING QUALITY, HAVING G-90 ZINC COATING IN PERFORMANCE WITH ASTM A90. WRAP ALL SUPPLY DUCT ON THE OUTSIDE WITH INSULATION. DUCT LINER IS NOT ALLOWED. c. DUCT PRESSURE CLASS SHALL NOT BE LESS THAN 3”TOTAL STATIC PRESSURE FOR SUPPLY DUCT; -½”W.G. FOR RETURN DUCT. B. ACCEPTABLE MANUFACTURER a. SPIRAL SEAM DUCTS: ROUND AND OVAL SPIRAL SEAM GALVANIZED STEEL DUCTS AND FITTINGS SHALL MEET REQUIREMENTS OF SMACNA. UNITED MCGILL CORP., CHAVEZ SHEET METAL, HERCULES INDUSTRIES, SHEET METAL PRODUCTS COMPANY, SEMCO, SPIR-L-OK (DUCTWORK ONLY) OR SPIRAL PIPE OF TEXAS. b. FLEXIBLE DUCTWORK: UL -181 LISTED, CLASS 1 FACTORY PRE-INSULATED DUCT WITH SOLID INNER LINER FORMED BY A REINFORCED ALUMINUM LAMINATE O OTHER REINFORCED MATERIAL MECHANICALLY BONDED OR LOCKED TOGETHER WITH A CORROSIVE RESISTANT GALVANIZED STEEL HELIX AND COVERED WITH A MINIMUM 1 ½”THICK FIBERGLASS BLANKET SHEATHED IN A POLYETHYLENE VAPOR BARRIER. INSULATION TO HAVE A 0.23 “C”FACTOR MAXIMUM, SHALL MEET FHA/HUD REQUIREMENTS AND HAVE A VAPOR BARRIER PERMEABILITY OF 0.10 PERMS (ASTM E96-PROCEDURE A). DUCT SHALL COMPLY WITH THE LATEST NFPA 90B STANDARD. PRESSURE RATINGS BASED ON TEST WITH TEMPERATURE AND VELOCITY APPLIED. DUCT MUST BE APPROVED BY CODE AUTHORITY FOR SPECIFIC APPLICATION. c.ROUND DUCT TAKE-OFF FITTINGS 1. SPIN-IN FITTING FOR ROUND DUCT CONNECTION FACTORY FABRICATED 26 GAUGE (ALL DIAMETERS) G-90 GALVANIZED SHEET METAL FOR INSULATED DUCTS, ADAPTOR PLATE OR GLASS FIBER DUCTS. BUTTERFLY DAMPER WITH QUADRANT OPERATOR AND LOCK NUT ON ALL APPLICATIONS EXCEPT VAV SYSTEM UP STREAM OF VAV BOX. 2.LATERAL TAKE-OFF FITTING FACTORY FABRICATED 26 GAUGE (ALL DIAMETERS) G-90 GALVANIZED SHEET METAL FITTINGS WITH 45 DEGREE ANGLE TAKE-OFF, ADHESIVE COATED GASKET, 1”MOUNTING FLANGE AND BUTTERFLY DAMPER WITH QUADRANT OPERATOR AND LOCK NUT ON ALL APPLICATIONS EXCEPT VAV SYSTEMS UPSTREAM OF VAV BOX. d.DUCT INSULATION ALL RECTANGULAR SUPPLY DUCT SHALL BE WRAPPED WITH INSULATED DUCT WRAP. INSULATE WITH 1 ½”THICK, ONE LB./CUBIC FOOT, UL RATED. SEAL ALL JOINTS. EXHAUST DUCT NEED NOT BE INSULATED. ALL INSULATION TO MEET THE REQUIREMENTS OF NFPA 90. EXECUTION 3.01 DUCTWORK A. DUCT SEALING ALL DUCTWORK SHALL BE SEALED PER SMACNA STANDARDS, CLASS A SEALING REQUIREMENTS. B.DUCTWORK TESTING SEE SECTION 200510 FOR TESTING OF DUCTWORK. C.DUCTWORK APPLICATION ALL DUCTWORK TO BE GALVANIZED STEEL MEETING ASTM A-527-71. D.TAKEOFFS 1. DO NOT INSTALL TAKEOFFS ON ELBOWS OR OTHER POINTS OF THE SYSTEM WHERE AIR VELOCITY IS NOT UNIFORM. 2. MAKE ALL RADIUS ELBOWS WITH RADIUS OF ONE AND ONE-HALF TIMES THE DIAMETER OR WIDTH OF DUCT AND AN INSIDE THROAT RADIUS OF ONE TIMES THE DIAMETER OR WIDTH. RADIUS ELBOWS IS THE PREFERRED METHOD FOR 90° DUCT TURNS. WHERE SPACE LIMITATION WILL NOT PERMIT RADIUS ELBOWS, PROVIDE 90° SQUARE ELBOWS WITH TURNING VANES. ALL 90° SQUARE ELBOWS ARE TO HAVE TURNING VANES EXCEPT WHERE SPECIFICALLY NOTED OTHERW ISE ON PLANS. 3. INSTALL OPPOSED BLADE DAMPERS IN ALL LOW VELOCITY DUCT DIVISIONS AND SPLITS WHERE SHOWN OR REQUIRED TO ALLOW SYSTEM BALANCE. INSTALL OPPOSED BLADE DAMPERS IN ALL 45° TAKEOFFS UNLESS SPECIFICALLY NOTED ON THE DRAWING. 4. SPIN-IN FITTING FINAL LOCATIONS SHALL BE DETERMINED AFTER LOCATION OF LIGHTING AND OTHER POSSIBLE OBSTRUCTIONS WITHIN THE CEILING SPACE ARE KNOWN SO THAT SHARP BENDS AND EXCESSIVE LENGTHS OF FLEXIBLE DUCT ARE MINIMIZED. 5. MAKE ALL DUCT OFFSETS WITH 15° OFFSETS, 30° OFFSETS MAXIMUM. E.DUCTWORK INSULATION 1. INSULATE ALL SUPPLY AND RETURN DUCTS, AND OUTSIDE AIR DUCTS AND WHEREVER ELSE CALLED FOR ON THE PLANS. EXHAUST DUCTS DO NOT REQUIRE INSULATION UNLESS SPECIFICALLY CALLED FOR. SUPPLY AND/OR RETURN DUCTWORK LOCATED WITHIN THE CONDITIONED SPACES SERVED BY THIS DUCTWORK DO NOT REQUIRE INSULATION. DUCTWORK PASSING THROUGH A SPACE THAT IS NOT SUPPLIED AIR BY THIS DUCTWORK REQUIRES INSULATION. CEILING PLENUMS AND MECHANICAL ROOMS ARE NOT CONDITIONED SPACES AND DUCT INSULATION IS REQUIRED. 2. RECTANGULAR AND SQUARE SUPPLY AND RETURN DUCTWORK SHALL BE WRAPPED ON THE OUTSIDE WITH DUCT BOARD. 3. ROUND SUPPLY: ROUND RETURN SHALL BE WRAPPED WITH INSULATION ON THE OUTSIDE UNLESS OTHERWISE NOTED. ROUND DUCT EXPOSED BELOW CEILINGS IN OCCUPIED AREAS SHALL NOT BE INSULATED. SEE SECTION 200700, INSULATION. 4. DUCTWORK EXPOSED TO WEATHER SHALL BE LINED WITH 2”THICK INSULATION WITH VAPOR BARRIER. SEAL DUCT JOINTS WEATHERTIGHT. 3.02 FLEXIBLE DUCTS ATTACH ALL FLEXIBLE DUCTS INNER LINE TO DUCT CONNECTORS, DIFFUSER NECKS, OR DUCTWORK WITH STAINLESS STEEL WORM-DRIVEN CLAMP. TAPE OUTER VAPOR BARRIER SECURELY OVER CLAMP WITH VAPOR BARRIER TAPE. END OF SECTION SECTION 230900 CONTROLS AND INSTRUMENTATION GENERAL 1.01 DESCRIPTION a. WORK INCLUDED a. FURNISH ALL LABOR, MATERIAL, EQUIPMENT, AND SERVICE NECESSARY FOR AN AUTOMATIC TEMPERATURE CONTROL (ATC) SYSTEM OF DIRECT DIGITAL CONTROLS, TO COMPRISE A COMPLETE SYSTEM, FURNISHED AND INSTALLED BY THE TEMPERATURE CONTROL MANUFACTURER OR BY THE MANUFACTURER’S REPRESENTATIVE. ATC SYSTEMS SHALL ADDRESS THE PROJECT AREA AND SCOPE, UNLESS OTHERWISE STATED. b. INTEGRATE ALL NEW WORK INTO EXISTING ATC SYSTEM. UPDATE EXISTING ATC SYSTEM GRAPHICS. c. THE SYSTEM SHALL BE COMPLETE IN ALL RESPECTS, PUT IN OPERATION AND CALIBRATED UNDER OCCUPIED CONDITIONS. d. LEAVE ANY EXISTING CONTROLS IN OPERATION UNTIL ANY NEW CONTROLS ARE READY TO OPERATE. b. GENERAL ALL AUTOMATIC CONTROL VALVES SHALL BE FURNISHED BY THE TEMPERATURE CONTROL CONTRACTOR (TTC) AND INSTALLED UNDER THE TCC SUPERVISION BY THE MECHANICAL DIVISION. ALL AUTOMATIC CONTROL DAMPERS AND AIR MONITOR STATIONS UNLESS OTHERWISE SPECIFIED, SHALL BE FURNISHED BY THE TCC AND INSTALLED UNDER THE TCC SUPERVISION BY THE MECHANICAL DIVISION. 1.02 WIRING ALL WIRING SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (LATEST EDITION), LOCAL CODES AND THE ELECTRICAL DIVISION OF THESE SPECIFICATIONS. 1.03 SUBMITTALS A. SHOP DRAWINGS SHALL BE SUBMITTED AT THE SAME SIZE AND SAME MATERIAL AS THE CONSTRUCTION DRAWINGS. THESE SHALL BE CORRECTED TO “RECORD”CONDITIONS AT THE END OF THE JOB AND INCLUDED WITH THE MECHANICAL “RECORD”DRAWINGS AS DESCRIBED IN SECTION 200500 AND DIVISION 1. B. SHOP DRAWINGS SHALL CONSIST OF ENGINEERING DATA ON EACH CONTROL SYSTEM COMPONENT, CONTROL DIAGRAMS, WIRING DIAGRAMS, DAMPER SCHEDULE, AUTOMATIC VALVE SCHEDULE WITH CVS, FLOWS AND PRESSURE DROP, SEQUENCE OF CONTROL, PIPING DIAGRAMS FOR ALL VALVES, CONTROL PANELS AND PANEL LAYOUTS, INSTALLATION AND CALIBRATION INSTRUCTIONS. CONTROL DIAGRAMS SHALL INCLUDE: a. SCHEMATIC REPRESENTATION OF SYSTEM UNDER CONTROL WITH FIELD DEVICES LOCATED, PIPED AND WIRED. b. CONTROL PANEL LAYOUT SHOWING INSTRUMENTS FULLY PIPED OR WIRED TO NUMBERED TERMINAL STRIPS. c. FRONT PANEL FACE LAYOUT WITH NAMEPLATE SCHEDULE, AND LOCATION IN BUILDING, FOR EACH PANEL. d. BILL OF MATERIAL; SCHEDULING ALL ITEMS BY USING CODE ABBREVIATION INDICATING QUANTITY, MANUFACTURER, MANUFACTURER’S CODE NUMBER, AND FULL EQUIPMENT DESCRIPTIVE LITERATURE, I.E., DAMPERS, VALVES, RELAYS, CONTROLLERS, SENSORS AND MISCELLANEOUS DEVICES. e. WRITTEN SEQUENCE OF CONTROL INCORPORATING INTO THE WRITTEN SEQUENCE ALL FUNCTIONAL DEVICES USING DEVICE CODE ABBREVIATION OR POINT NUMBER. f. CALIBRATION SCHEDULE AND SET POINT FOR EVERY DEVICE. C. PROGRAMMING MANUAL PROVIDE A PROGRAMMING MANUAL DESCRIBING PROGRAMMING AND TESTING, SYSTEM STARTING, A SYSTEM OVERVIEW, AND A DETAILED DESCRIPTION OF EACH SOFTWARE FEATURE. THE MANUAL SHALL INSTRUCT THE USER ON PROGRAMMING OR REPROGRAMMING ANY PORTION OF THE SYSTEM AND INCLUDE ALL CONTROL PROGRAMS, VARIABLES, SET POINTS, TIME PERIODS, MESSAGES, PASSWORDS AND OTHER INFORMATION NECESSARY TO LOAD, ALTER, TEST, AND EXECUTE THE SYSTEM. THE MANUAL SHALL ALSO INCLUDE: a. COMPLETE DESCRIPTIONS OF THE PROGRAMMING LANGUAGE INCLUDING COMMANDS, EDITING AND WRITING CONTROL PROGRAMS; THE PRINTOUTS AND LOGS; AND MATHEMATICAL CALCULATIONS. b. INSTRUCTIONS ON MODIFYING ANY CONTROL POINTS, VERIFYING ERROR STATUS, CHANGING PASSWORDS, AND INITIATING OR DISABLING CONTROL PROGRAMS. c. AN OPERATOR’S REFERENCE TABLE LISTING THE ADDRESSES OF ALL CONNECTED INPUT POINTS AND OUTPUT POINTS. INITIAL SETTINGS SHALL BE SHOWN WHERE APPLICABLE. d. CONTROL ALGORITHMS D.CONTROL ALGORITHMS ALL CONTROL SEQUENCES SHALL BE DESCRIPTIVELY SHOWN BY THE USE OF LOGIC FLOW CHARTS INCORPORATING THE SAME POINT NAMES AS USED IN THE PROGRAM AND GIVING ALL CONTROL EQUATIONS USED. E.OPERATIONAL AND MAINTENANCE DATA SUBMIT THE FOLLOWING IN ACCORDANCE WITH SECTION 200500. a. GENERAL INSTRUCTION SHEETS FOR ALL PRODUCTS AND DEVICES FURNISHED UNDER THE ATC SPECIFICATIONS. b. PARTS LISTS, AVAILABILITY (SUPPLIER NAME, TELEPHONE NUMBER AND LOCATION), AND GUARANTEE OF LOCAL STOCK FOR ALL PRODUCTS AND DEVICES FURNISHED UNDER THE ATC SPECIFICATIONS. c. LIST OF RECOMMENDED SPARE EQUIPMENT, ALONG WITH QUANTITIES, THE OWNER SHOULD MAINTAIN ON SITE. d. TWO COPIES OF OPERATORS AND PROGRAMMERS MANUALS. e. FINAL APPROVES SET OF ALL SHOP DRAWING SUBMITTALS. f. AS BUILT DRAWINGS. g. POINT VALIDATION CERTIFICATION. 1.04 ADJUSTABILITY ALL CONTROL COMPONENTS SHALL BE COMPLETELY ADJUSTABLE, SO THAT SETPOINTS MAY BE EASILY CHANGED. ALL SETPOINTS IN THE TEMPERATURE CONTROL SYSTEM SHALL BE ADJUSTABLE WITHOUT THE ADDITION OR MODIFICATION OF CONTROLS. 1.05 DEMONSTRATION, TRAINING AND COMPLETION UPON COMPLETION OF THE INSTALLATION OF THE ATC CONTRACTOR SHALL PROVIDE A MINIMUM OF 8 HOURS OF COMPLETE SYSTEM INSTRUCTION AND TRAINING TO THE OWNER’S OPERATING PERSONNEL. THE TRAINING SESSION(S) SHALL BE CONDUCTED AT THE BUILDING. TWO COPIES OF THE AS-BUILT SHOP DRAWING AND OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED AT THE TRAINING SESSION. 1.06 WARRANTY IN ACCORDANCE WITH SECTION 200500 THE CONTROL SYSTEM SHALL BE WARRANTEED TO BE FROM DEFECTS IN WORKMANSHIP AND MATERIAL FOR THE PERIOD INDICATED IN SECTION 200500. THE ATC CONTRACTOR SHALL MAKE ALL NECESSARY REPAIRS, ADJUSTMENTS AND REPLACEMENTS AT NO COST TO THE OWNER DURING THE WARRANTY PERIOD. PRODUCTS 2.01 ACCEPTABLE MANUFACTURER’S AND INSTALLERS A. MANUFACTURER: TRANE B. ALL CONTROLS SHALL BE OF ONE MANUFACTURER. IT IS RECOGNIZED THAT PACKAGED EQUIPMENT COMES WITH OTHER NAMES OR CONTROLS AND THAT SOME FUNCTIONS ARE ACCOMPLISHED WITH OTHER NAMED COMPONENTS. THIS SPECIFICATION DOES NOT INTEND TO PROHIBIT THIS PRACTICE. C. THE ATC CONTRACTOR IS RESPONSIBLE FOR PRE-ASSEMBLING AND INSTALLING PANELS AND ALL HARDWARE W ITH OWN EMPLOYEES, PROVING THE SYSTEM AND TRAINING THE OWNER’S OPERATING PERSONNEL IN ITS PROPER FUNCTION AND MAINTENANCE. ATC CONTRACTOR MAY SUBCONTRACT WIRING, CONDUIT PLACEMENT, BUT SHALL MAKE ALL WIRING TERMINATIONS AND BE RESPONSIBLE FOR THE SUBCONTRACTOR’S WORK. 2.02 LOW VOLTAGE POWER AND WIRING A. ALL CONTROL DEVICES AND PANELS CONTAINING LOW VOLTAGE POWER SOURCES SHALL INHERENTLY COMPLY WITH NEC CLASS 2 REQUIREMENTS (CURRENT LIMITING), OR SHALL BE SUPPLIED WITH BRANCH CIRCUIT FUSING TO LIMIT CONTROL CIRCUIT CURRENT TO NEC CLASS 2. ALL CONTROL TRANSFORMERS SHALL BE OF THE INHERENT CURRENT LIMITING TYPE, OR SHALL BE INSTALLED WITH PRIMARY DISCONNECT AND OVERLOAD PROTECTION. 2.03 SENSORS A. TEMPERATURE a. ELECTRONIC TEMPERATURE SENSORS SHALL BE PLATINUM OR NICKEL-IRON RTD, THIN FILM INTEGRATED CIRCUIT, OR AGED THERMISTORS. RESISTANCE CHANGE VERSES TEMPERATURE SHALL BE LINEAR OVER THE RANGE OF THE APPLICATION. SENSOR ACCURACY SENSOR FUNCTION ACCURACY RANGE SPACE TEMPERATURE ±1.5°F 55°F TO 90°F DUCT TEMPERATURE ±1°F 40°F TO 120°F HEATING WATER TEMP.±2°F 80°F TO 230°F b.AVERAGING TEMPERATURE SENSORS: SHALL BE PROVIDED IN ALL DUCT APPLICATIONS WITH CROSS SECTION OF OVER 10 SQ. FT. SENSOR SHALL BE AN AVERAGING TYPE CAPILLARY OF NOT LESS THAN FIFTEEN FEET. CAPILLARY SHALL BE SERPENTINED ACROSS THE DUCT FOR AN AVERAGE OF ONE LINEAR FOOT OF CAPILLARY PER ONE SQUARE FOOT OF CROSS SECTIONAL DUCT AREA. WHERE MULTIPLE COIL SECTIONS EXIST, SEPARATE CAPILLARIES SHALL BE PROVIDED FOR EACH SECTION. c.OUTSIDE AIR SENSORS SHALL BE SUITABLE FOR OUTDOOR USE. INSTALL SENSORS WITH SHIELD AND LOCATED WHERE UNAFFECTED BY THE SUN. d.LIQUID SENSORS SHALL BE PROVIDED WITH SEPARABLE WELLS. B.PRESSURE PRESSURE SENSORS SHALL BE TEMPERATURE COMPENSATED FOR THE EXPECTED TEMPERATURES OF THE APPLICATION. a. DUCT PRESSURE SENSOR SHALL HAVE A RANGE OF 0 TO 3”W.C., 0 TO 0.5”W.C., OR AS REQUIRED FOR APPLICATION, REPEATABILITY OF +1.5% OF RANGE, ACCURACY OF + 3% OF RANGE. b. BUILDING STATIC PRESSURE SENSOR SHALL HAVE A MAXIMUM RANGE OF -0.5 TO 0.5”W.C., REPEATABILITY OF +1% OF SPAN AND ACCURACY +2% OF SPAN. c. PIPE STATIC PRESSURE SENSOR SHALL HAVE A MAXIMUM RANGE OF 0 TO 30 PSI, REPEATABILITY OF +1% RANGE AND ACCURACY OF +0.25% OF SPAN. CORROSION RESISTANT, DIAGHRAM OR BOURDON TUBE TYPE SENSING ELEMENT. ADJUSTABLE RANGE SETTINGS. PROVIDE PROPER SHUTOFF AND BLEED VALVES. d.AIR DIFFERENTIAL PRESSURE SWITCHES SHALL BE SINGLE CONTACT FOR ACTUATION ON DECREASING PRESSURE (NORMALLY CLOSED), 0.5”TO 2.0”RANGE. RELAY RATING OF 15 AMPS AT 1 20-480 VAC. C.HUMIDITY SENSORS: SHALL BE HYGROSCOPIC ELEMENT OR POLYMER FILM WHICH IS PROTECTED WITH A DUST COVER IN DUCT APPLICATIONS. SENSOR RANGE SHALL BE MINIMUM 20% TO 80% RH WITH +3% RH ACCURACY. FOR DUCT APPLICATIONS DOWN STREAM OF COOLING COILS, SENSOR RANGE SHALL BE 40% TO 100% RH WITH +4% RH ACCURACY. MINIMUM REPEATABILITY SHALL BE 3% OVER RANGE GIVEN. D.FLOW SENSORS: INSERTION TYPE WITH IMPEDANCE SENSING (NON-MAGNETIC AND NON-PHOTOELECTRIC) TURBINE METER WITH NON-METALLIC ROTORS MOUNTED WITH SAPPHIRE BEARINGS AND TUNGSTEN SHAFTS. ACCURACY OF +2% OF ACTUAL READING FROM 0.4 TO 20 FEET PER SECOND. RATED FOR 400 PSI AND 220°F. VOLTAGE OUTPUT OF 0-10V AND CURRENT OUTPUT OF 4-20 MA. FREQUENCY OUTPUT OF 0-15 VDC, PEAK TO PEAK. PROVIDE MANUFACTURER’S HOT TAP INSTALLATION HARDWARE WITH ALL METERS. PROVIDE DUAL TURBINE MODEL WHERE REQUIRED. ONICON MODEL OR APPROVED EQUIVALENT. E.AIRFLOW SENSOR PROBE SHALL BE EXTRUDED ALUMINUM CONSTRUCTION AND CONTAIN MULTIPLE TOTAL AND STATIC PRESSURE SENSORS LOCATED ALONG THE EXTERIOR SURFACE OF THE CYLINDRICAL PROBE AND INTERNALLY CONNECTED TO THEIR RESPECTIVE AVERAGING MANIFOLDS. STATIC PRESSURE SENSORS SHALL BE OF THE OFFSET (FECHHEIMER) DESIGN AND THE TOTAL PRESSURE SENSORS SHALL INCORPORATE CHAMBERED SENSING PROBE. FLOW MEASUREMENT SHALL NOT BE AFFECTED BY YAW OR PITCH OF PROBE UP TO 30 DEG. SIGNAL CONNECTION TAKE-OFF FITTINGS SHALL BE MIDPOINT OF PROBE. PROBE SHALL BE CAPABLE OF PRODUCING STEADY NON-PULSATING SIGNALS OF TOTAL AND STATIC PRESSURE WITHOUT NEED FOR FLOW CORRECTIONS OR FACTORS, WITH AN INSTRUMENT ACCURACY OF 0.2%, OVER A VELOCITY RANGE OF 400 TO 2500 FPM. PROVIDE NUMBER OF PROBES RECOMMENDED BY MANUFACTURER FOR PROPER AREA COVERAGE. 2.04 CONTROLLERS A. THERMOSTATS GENERAL ALL THERMOSTATS SHALL HAVE A TEMPERATURE RANGE SUITABLE FOR THE APPLICATION AND SHALL HAVE ADJUSTABLE SETPOINTS. ALL ROOM THERMOSTATS SHALL HAVE CONCEALED ADJUSTMENT AND LOCKING COVER. ALL ROOM THERMOSTATS THAT CONTROL BOTH HEATING AND COOLING SHALL HAVE A SEPARATE SETPOINT FOR HEATING AND COOLING (CAN BE ACCOMPLISHED BY INDIVIDUAL THERMOSTATS LOCATED UNDER ONE COVER) OR HAVE SEPARATE HEATING AND COOLING CONTROL POINTS PROVIDED THROUGH THERMOSTAT’S ADJUSTABLE THROTTLING RANGE. 2.05 ACTUATORS A. ELECTRONIC ACTUATOR (FOR DAMPERS AND VALVES) a. ELECTRONIC DIRECT-COUPLED ACTUATION SHALL BE PROVIDED ON ALL DAMPERS. THE FASTENING CLAMP SHALL ATTACH TO THE DAMPER SHAFT FOR MAXIMUM STRENGTH AND ELIMINATE SLIPPAGE. SINGLE BOLT OR SCREW TYPE FASTENERS ARE NOT ACCEPTABLE. b. ACTUATORS SHALL HAVE ELECTRONIC OVERLOAD OR DIGITAL ROTATION SENSING CIRCUITRY TO PREVENT DAMAGE TO THE ACTUATOR THROUGHOUT THE ENTIRE ROTATION OF THE ACTUATOR. MECHANICAL END SWITCHES OR MAGNETIC CLUTCH TO DEACTIVATE THE ACTUATOR AT THE END OF ROTATION ARE NOT ACCEPTABLE. c. FOR POWER-FAILURE/SAFETY APPLICATIONS, AN INTERNAL MECHANICAL, SPRING RETURN MECHANISM SHALL BE BUILT INTO THE ACTUATOR HOUSING. NON-MECHANICAL FORMS OF FAIL-SAFE ARE NOT ACCEPTABLE. ALL SPRING RETURN ACTUATORS SHALL BE CAPABLE OF BOTH CLOCKWISE AND COUNTERCLOCKWISE SPRING RETURN OPERATION BY SIMPLY CHANGING THE MOUNTING ORIENTATION. d. ALL ACTUATORS SHALL HAVE A VISUAL POSITION INDICATOR TO INDICATE CONTROL POSITION OF THE ACTUATOR. e. ACTUATORS SHALL BE APPLIED ACCORDING TO THE VALVE OR DAMPER MANUFACTURER’S SPECIFICATIONS. f. ACTUATORS SHALL BE UNDERWRITERS LABORATORIES STANDARD 873 LISTED AS MEETING CORRECT SAFETY REQUIREMENTS AND RECOGNIZED INDUSTRY STANDARDS. ACTUATORS SHALL HAVE A 2-YEAR MANUFACTURER’S WARRANTY, STARTING FROM THE DATE OF SUBSTANTIAL COMPLETION. 1. VAV CONTROL UNIT ELECTRONIC ACTUATORS: ROTARY OR LINEAR DRIVE TYPE CAPABLE OF CONTINUOUS STALL WITHOUT DAMAGE. ROTARY DRIVE ACTUATORS SHALL HAVE ADJUSTABLE STOP PINS AND SHALL FIT DIRECTLY OVER THE DAMPER SHAFT. GEARS AND BEARINGS SHALL BE OIL IMPREGNATED STEEL. 2. WHEN APPLICATION (SEE SEQUENCE OF CONTROL) REQUIRES NORMALLY OPEN OR NORMALLY CLOSED DAMPER POSITION, ACTUATOR MUST HAVE SPRING RETURN. NON-MECHANICAL FORMS OF FAIL-SAFE OPERATION ARE NOT ACCEPTABLE. 3. ACTUAL ACTUATOR POSITION AS A PERCENTAGE OF FULL TRAVEL SHALL BE KNOWN AND CONTROLLED BY THE DDC SYSTEM. 2.06 DAMPERS DAMPER FRAMES SHALL BE 13 GAUGE GALVANIZED STEEL CHANNEL OR 1/8”EXTRUDED ALUMINUM WITH REINFORCED CORNER BRACING. DAMPER BEARINGS SHALL BE NYLON, TEFLON OR OIL IMPREGNATED BRONZE. DAMPER BLADES SHALL NOT EXCEED 8”IN WIDTH. MAXIMUM DAMPER SECTION WIDTH TO BE 48 INCHES. BLADES ARE NOT TO BE SUITABLE FOR HIGH VELOCITY PERFORMANCE. ALL EDGES OF THE BLADES AND TOP, BOTTOM AND SIDES OF THE FRAME SHALL BE PROVIDED W ITH REPLACEABLE, BUTYL RUBBER OR NEOPRENE SEALS. SIDE SEALS MAY BE SPRING LOADED STAINLESS STEEL. THE SEALS SHALL PROVIDE A MAXIMUM OF 1% LEAKAGE WHEN SIZED AT A WIDE OPEN FACE VELOCITY OF 1500 FPM, 4”STATIC PRESSURE. THE DAMPER LEAKAGE SHALL PROVIDE A LINEAR FLOW OF EQUAL PERCENTAGE CHARACTERISTIC AS REQUIRED. 2.07 VALVES GENERAL ALL VALVES TO HEATING COILS WHICH ARE PART OF AN AIR HANDLING SYSTEM WHICH TAKES IN OUTSIDE AIR SHALL OPEN FOR FULL SUPPLY WATER FLOW FROM HEATING GENERATION PLANT WHENEVER A LOSS OF POWER OR AIR SUPPLY TO THE VALVES OCCURS. ALL VALVES SHALL CLOSE AGAINST FLOW. ALL CONTROL VALVES SHALL CONFORM TO THE PRESSURE CLASS REQUIREMENTS OF GLOBE VALVES AS SPECIFIED IN SECTION 232100, UNLESS LISTED DIFFERENTLY BELOW. EXECUTION 3.01 ACCESSIBILITY INSTALL ALL CONTROL DEVICES IN “READILY ACCESSIBLE”LOCATIONS AS DEFINED BY CHAPTER 1, ARTICLE 100, PART A OF THE NATIONAL ELECTRICAL CODE. 3.02 CONTROL PANELS THE PANELS SHALL BE TOTALLY ENCLOSED WITH HINGED DOOR AND CONTAINING ASSOCIATED CONTROL COMPONENTS SUCH AS CONTROLLERS, RELAYS, SWITCHES, GAUGES, MICROPROCESSOR, MODEM, COMMUNICATION INTERFACE, OVERRIDE TIMERS, ETC. PANEL TO MEET NEMA ONE REQUIREMENTS WITH PROPER BRACING FOR RIGID WALL OR FLOOR MOUNTING. 3.03 WIRING A. INSTALLATION OF WIRING, CABLE, CONDUIT, ETC. SHALL CONFORM TO DIVISION 16. IN CASE OF CONFLICT BETWEEN THIS DIVISION AND DIVISION 16, THE MOST STRINGENT REQUIREMENTS SHALL BE MET. B. ALL WIRING SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL TO BUILDING LINES AND SUSPENDED NEATLY FROM THE OVERHEAD STRUCTURE (DO NOT LAY WIRING ON TOP OF CEILING TILES). 3.04 RELATED WORK IN OTHER SECTIONS A. COORDINATE ALL WORK PERFORMED UNDER THE MECHANICAL DIVISION INCLUDING: a. PIPING 1. INSTALL AUTOMATIC VALVES AND SEPARABLE WELLS THAT ARE SUPPLIED UNDER THIS SECTION. 2. FURNISH AND INSTALL NECESSARY PRESSURE TAPS, WATER, DRAIN AND OVERFLOW CONNECTIONS AND PIPING. 3. FURNISH AND INSTALL NECESSARY PIPING CONNECTIONS REQUIRED FOR FLOW SERVICES. b. SHEET METAL 1. INSTALL AUTOMATIC DAMPERS AND PROVIDE NECESSARY BLANK-OFF PLATES OR TRANSITIONS REQUIRED TO INSTALL DAMPERS THAT ARE SMALLER THAN DUCT SIZE. 2. PROVIDE ACCESS DOORS OR OTHER APPROVED MEANS OF ACCESS THROUGH DUCTS FOR SERVICE TO CONTROL EQUIPMENT. 3.05 COMPLETION SERVICES A. POINT VALIDATION UPON THE COMPLETION OF THE INSTALLATION, USING WALKIE-TALKIES (AS REQUIRED) COMPLETELY VALIDATE THE PROPER OPERATION AND LABELING OF ALL INPUT AND OUTPUT POINTS. B.DEMONSTRATIONS AT THE COMPLETION OF THE WORK, INSTRUCT THE OWNER’S OPERATING PERSONNEL AND DEMONSTRATE TO THE ENGINEER THE PROPER OPERATION OF THE CONTROL SYSTEMS. THE ATC CONTRACTOR SHALL PROVIDE A MINIMUM 8 HOURS OF SYSTEM INSTRUCTION TO THE OWNER. END OF SECTION SECTION 230593 TESTING, ADJUSTING AND BALANCING GENERAL 1.01 WORK INCLUDED THIS SECTION COVERS TESTING AND BALANCING OF ENVIRONMENTAL SYSTEMS INCLUDING BUT NOT LIMITED TO AIR DISTRIBUTION SYSTEMS AND THE EQUIPMENT AND APPARATUS CONNECTED THERETO. THE TESTING AND BALANCING OF ALL ENVIRONMENTAL SYSTEMS SHALL BE THE RESPONSIBILITY OF ONE TESTING, BALANCING AND ADJUSTING FIRM. 1.02 QUALIFICATIONS OF CONTRACTOR THE GENERAL CONTRACTOR SHALL PROCURE THE SERVICES OF AN INDEPENDENT TESTING AND BALANCING FIRM SPECIALIZED IN THIS WORK. THE FIRM MUST HAVE A REGISTERED PROFESSIONAL ENGINEER, AN AABC CERTIFIED TEST AND BALANCE ENGINEER, OR A NEBB CERTIFIED TESTING, BALANCING AND ADJUSTING SUPERVISOR, WHO IS AN EMPLOYEE OR PRINCIPLE OF THE FIRM, IN CHARGE OF THE WORK AND MUST HAVE A LOCAL OFFICE WITH RESIDENT PERSONNEL WITHIN 100 MILES OF THE PROJECT. 1.03 SEQUENCING AND SCHEDULING SEQUENCE WORK TO COMMERCE AFTER COMPLETION OF SYSTEMS AND START-UP PROCEDURES AS DESCRIBED IN SECTION 200500 AND SCHEDULE COMPLETION OF WORK BEFORE SUBSTANTIAL COMPLETION OF PROJECT. PRODUCTS 2.01 ACCEPTABLE AGENCIES A. FIRMS ACCEPTABLE TO DO THE WORK ARE: a. GRIFFITH ENGINEERING b. JPG EXECUTION 3.01 COORDINATION A. TESTING AND BALANCING CONTRACTOR SHALL VISIT THE SITE AND COORDINATE WITH MECHANICAL CONTRACTOR TO MAKE SURE ALL ITEMS SUCH AS: THERMOMETER WELLS, PRESSURE TEST COCKS, ACCESS DOORS, ETC., ARE FURNISHED AND INSTALLED AS REQUIRED TO ALLOW TESTS AND ADJUSTMENTS TO BE MADE AS DESCRIBED IN THIS SECTION. B. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL SUCH DEVICES REQUIRED TO ALLOW THE BALANCING TO BE ACCOMPLISHED. 3.02 STATUS OF SYSTEMS A. AIR TESTING AND BALANCING SHALL NOT BEGIN UNTIL THE SYSTEMS HAVE BEEN COMPLETED AND ARE IN FULL WORKING ORDER. B. PROMPTLY REPORT DEFECTS OR DEFICIENCIES NOTED DURING BALANCE OR ABNORMAL CONDITIONS IN THE MECHANICAL SYSTEM WHICH PREVENT SYSTEM BALANCE TO THE APPROPRIATE RESPONSIBLE PERSON. 3.03 ADJUSTING AND BALANCING A. ADJUST AND BALANCE ALL AIR SYSTEMS WITHIN +10% TO -5% OF DESIGN FLOW RATES. CHECK, ADJUST AND BALANCE ALL SYSTEMS TO MEET THE DESIGN CONDITIONS AND TABULATE ALL INFORMATION IN ACCEPTABLE FORMS. ALL SYSTEMS SHALL BE CHECKED FOR PROPER PERFORMANCE DURING DESIGN CONDITIONS, BOTH HEATING AND COOLING. B. RECORDED DATA SHALL REPRESENT ACTUAL MEASURED OR OBSERVED CONDITION. C. PERMANENTLY MARK SETTINGS OF DAMPERS, AND OTHER ADJUSTMENT DEVICES ALLOWING SETTINGS TO BE RESTORED. SET AND LOCK ALL MEMORY STOPS. D. AFTER ADJUSTMENT, TAKE MEASUREMENTS TO VERIFY BALANCE HAS NOT BEEN DISRUPTED OR THAT SUCH DISRUPTION HAS BEEN RECTIFIED. E. LEAVE SYSTEMS IN PROPER WORKING ORDER, REPLACING BELT GUARDS, CLOSING ACCESS DOORS, CLOSING DOORS OR COVERS TO ELECTRICAL SWITCH BOXES, PLUGGING TEST HOLES IN DUCTWORK WHERE READING WERE TAKEN AND RESTORING THERMOSTATS TO SPECIFIED SETTINGS. 3.04 TEMPERATURE CONTROLS A. INSPECT ALL TEMPERATURE CONTROL SYSTEMS FOR PROPER SEQUENCE OF OPERATION, COMPLETENESS AND APPROXIMATE CALIBRATION. REPORT ANY DEFICIENCIES TO THE RESPONSIBLE CONTRACTOR IMMEDIATELY. 3.05 AIR BALANCE A. ADJUST AIR HANDLING AND DISTRIBUTION SYSTEMS TO PROVIDE REQUIRED OR DESIGN SUPPLY, RETURN AND EXHAUST AIR QUANTITIES AT SITE ALTITUDE. MEASURE AIR QUANTITIES AT INLETS AND OUTLETS. 3.06 REPORT OF WORK A. THIS CONTRACTOR SHALL SUBMIT A MINIMUM OF FOUR (4) BOUND COPIES OF THE FINAL TESTING AND BALANCING REPORT AT LEAST 7 DAYS PRIOR TO THE MECHANICAL CONTRACTOR’S REQUEST FOR FINAL INSPECTION. ALL DATA SHALL BE RECORDED ON APPLICABLE REPORTING FORMS. THE REPORT SHALL INCLUDE ALL OPERATING DATA, A LIST OF ALL EQUIPMENT USED IN THE TESTING AND BALANCING WORK, AND SHALL BE SIGNED BY THE SUPERVISING ENGINEER AND AFFIXED WITH A CERTIFICATION SEAL. ALSO INCLUDE PROJECT ALTITUDE AND ANY CORRECTION FACTORS USED IN THE CALCULATIONS. FINAL ACCEPTANCE OF THIS PROJECT WILL NOT TAKE PLACE UNTIL A SATISFACTORY REPORT IS RECEIVED. B. AFTER ALL BALANCING IS COMPLETE AND ALL COORDINATION WITH THE CONTRACTOR AND THE ENGINEER IS COMPLETE, THE BALANCING FIRM SHALL FURNISH BOUND REPORTS WHICH CONTAIN THE FOLLOWING INFORMATION. ALL INFORMATION LISTED BELOW SHALL BE INCLUDED IN REPORT UNLESS WRITTEN APPROVAL FOR DELETION OF ITEMS IS AGREED TO BE MECHANICAL ENGINEER PRIOR TO START OF BALANCING. a. TITLE PAGE INCLUDING COMPANY NAME, ADDRESS AND TELEPHONE NUMBER; PROJECT NAME AND LOCATION; PROJECT ARCHITECT; PROJECT ENGINEER; PROJECT CONTRACTOR; PROJECT ALTITUDE. b. INSTRUMENT LIST INCLUDING INSTRUMENT, MANUFACTURER, MODEL, SERIAL NUMBER, RANGE, CALIBRATION DATE. c. ELECTRIC MOTOR DATA INCLUDING MANUFACTURER, HP, VOLTAGE, PHASE, AMPERAGE (NAME PLATE, ACTUAL (IN ALL OPERATING MODES), NO LOAD), SERVICE FACTOR, EFFICIENCY, POWER FACTOR, STARTER SIZE (BRAND, MODEL, ENCLOSURE TYPE, INSTALLED THERMAL HEATERS AND THE RATING OF THE HEATERS, REQUIRED THERMAL HEATERS AND THE RATING OF THE HEATERS IF DIFFERENT THAN INSTALLED). d. V-BELT DRIVE DATA INCLUDING IDENTIFICATION/LOCATION, REQUIRED DRIVEN RPM; DRIVEN SHEAVE (DIAMETER AND RPM), BELT (SIZE AND QUALITY), MOTOR SHEAVE (DIAMETER AND RPM), CENTER TO CENTER DISTANCE (MAXIMUM, MINIMUM AND FINAL). e. AIR MOVING EQUIPMENT DATA INCLUDING LOCATION, MANUFACTURER, MODEL, SUPPLY AIR FLOW (SPECIFIED AND ACTUAL), RETURN AIR FLOW (SPECIFIED AND ACTUAL), OUTSIDE AIR FLOW (SPECIFIED AND ACTUAL), TOTAL STATIC PRESSURE (SPECIFIED AND ACTUAL), INLET PRESSURE, DISCHARGE PRESSURE, FAN RPM, MOTOR AND V-BELT DRIVE INFORMATION AS PREVIOUSLY MENTIONED. a. STATIC PRESSURE ACROSS EACH INDIVIDUAL COMPONENT OF THE SYSTEM AND THE TOTAL SYSTEM. b. OUTSIDE/RETURN AIR DATA INCLUDING IDENTIFICATION/LOCATION, SUPPLY AIR FLOW (SPECIFIED AND ACTUAL), RETURN AIR FLOW (SPECIFIED AND ACTUAL), MINIMUM OUTSIDE AIR FLOW (SPECIFIED AND ACTUAL), EXHAUST AIR FLOW (SPECIFIED AND ACTUAL), RETURN AIR TEMPERATURE, OUTSIDE AIR TEMPERATURE, MIXED AIR TEMPERATURE (SPECIFIED AND ACTUAL). a. DUCT TRAVERSE DATA INCLUDING SYSTEM ZONE/BRANCH, DUCT SIZE, AREA, DESIGN VELOCITY, DESIGN AIR FLOW, TEST VELOCITY, TEST AIR FLOW, DUCT STATIC PRESSURE, AIR TEMPERATURE, AIR CORRECTION FACTOR. REDUCED DRAWINGS INCLUDED WITH BALANCE REPORT SHALL INDICATE ALL DUCT TRAVERSE LOCATIONS. 3.07 COMPLETION SERVICES A. THE BALANCING FIRM SHALL MAKE ANY CHANGES OF FAN BELTS AND SHEAVES TO OBTAIN THE REQUIRED CFM AND MAKE OTHER CORRECTIONS TO THE SYSTEMS FOR PROPER PERFORMANCE AS REQUESTED BY THE CONSULTING MECHANICAL ENGINEER OR OWNER. A. FINAL ACCEPTANCE OF THE PROJECT WILL NOT BE MADE UNTIL A SATISFACTORY REPORT IS RECEIVED. WHEN DEEMED NECESSARY BY THE OWNER OR ENGINEER, THE BALANCING FIRM SHALL RUN TEMPERATURE AND/OR HUMIDITY RECORDINGS AND SHALL READ ANY OF THE REPORT QUANTITIES IN THE PRESENCE OF THE OWNER OR ENGINEER FOR VERIFICATION PURPOSES. END OF SECTION 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 12" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/25/2024 1:48:14 PM 1/25/2024 1:48:14 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt M003 01/24/2024 23289 MECHANICAL SPECIFICATIONS KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 11/08/2024 T T T T 19 Q P O P.9 AA 19.4 20 21 21.4 22 22.8 23 24 25 25.4 N.M. WAITING (EXISTING) 1614 CHECK-IN/ WAITING (EXISTING) 1601 PATIENT TOILET (EXISTING) 1625 LOCKERS (EXISTING) 1610 HALL (EXISTING) X101 STRESS TEST (EXISTING) 1611 STORAGE (EXISTING) 1809 GENERAL COUNSELOR (EXISTING) X74 CEO OFFICE (EXISTING) X75 ADMIN ASSISTANT (EXISTING) X70 DIRECTOR OF MARKETING (EXISTING) X72 200 D1 160 D1 250 D1 250 D1 250 D1 250 D1 (E)18x10 (E ) 8 ø (E ) 8 ø (E ) 1 2 ø (E)8ø (E)12x10 (E)10x10(E)8ø (E ) 1 2 x 1 2 (E)12x12 (E)8x10 (E)VAV PH3.2 (E)VAV PH3.3 VAV PH4.1 1 3 3 4 1 5 5 2 (E)CWR (E)CWS (E)HWR (E)HWS (E)3/4" HWR (E)3/4" HWS 6 7 8 CONTRAST MEDIA PREP AREA-2 1613-2 N.M .TECH 1612 N.M. / CT IMAGING 1622 HALL (EXISTING) X101 (E)34x16 RA (E)38x38 RA(E)38x38 RA (E)34x16 RA 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/4" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/25/2024 1:48:16 PM 1/25/2024 1:48:16 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt M101 01/24/2024 23289 MECHANICAL & PIPING DEMOLITION KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/4" = 1'-0"1 LEVEL 01 - DEMO PLAN - MECHANICAL & PIPING 1. MECHANICAL SYMBOLS AND ABBREVIATIONS SHEET GENERAL NOTES APPLY TO ALL SHEETS. 2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS. 3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED. 4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM THIS WORK. 5. MECHANICAL WORK IS EFFECTING AREAS OUTSIDE OF THE ARCHITECTURAL SCOPE OF WORK, MECHANICAL CONTRACTOR SHALL COORDINATE AREAS OF DISRUPTION AND IMPACT WITH OWNER AND GENERAL CONTRACTOR PRIOR TO BEGINING WORK. SHEET NOTES: 1. REMOVE SUPPLY DUCTWORK. CAP AND SEAL REMAINING DUCTWORK MAIN. 2. REMOVE EXISTING SUPPLY MAIN UP TO RTU-11. PREPARE RTU CONNECTION FOR NEW 18" SUPPLY MAIN CONNECTION. REFER TO MH201 FOR FURTHER INFORMATION. 3. REMOVE VAV AND ASSOCIATED THERMOSTAT. DISCONNECT HWS/R PIPING AND REMOVE BACK TO MAIN. 4. REMOVE VAV AND ASSOCIATED THERMOSTAT. DISCONNECT HWS/R PIPING AND PREPARE FOR CONNECTION TO NEW. 5. REMOVE RETURN GRILLES AND ASSOCIATED DUCTWORK BACK TO MAIN. CAP AND SEAL REMAINING RETURN DUCTWORK. 6. CONTRACTOR SHALL CONFIRM IF PIPING BRANCH SERVES ANY OTHER EQUIPMENT WITH THE CONTINUED BRANCH OF PIPING. IF HWS/R PIPE BRANCH IS A DEAD-LEG, REMOVE BRANCH PIPING. 7. EXISTING RETURN MAIN UP TO RTU-11. 8. EXISTING TANK ABOVE CEILING APPEARS TO BE ABANDONED IN PLACE. APPEARS TO BE APART OF AN OLD CONDENSATE RETURN SYSTEM. IF INACTIVE AND IF APPROVED BY AVH FACILITIES, REMOVE TANK AND CAP EXISTING PIPING. GENERAL NOTES: 11/08/2024 THERMOSTAT/ HUMIDISTAT (ADA) 48" THERMOSTAT/ HUMIDISTAT 60" ROOM PRESSURE MONITOR 60" MEDICAL GAS OUTLETS 60"66" MEDICAL GAS ALARM PANELS 66" MEDICAL GAS ZONE VALVE BOX MEDICAL GAS CONTROL PANEL 62" A. COORDINATE ELEVATION OF DEVICES WITH ALL ADJACENT DEVICES INCLUDING THOSE WITH OTHER TRADES. ALL DEVICES WHICH HAVE ADA AND NON-ADA HEIGHTS LISTED SHALL BE MOUNTED TO COMPLY WITH ADA EXCEPT WHERE NOTED ON THE PLANS AS NON-ADA. B. GROUP DEVICES IN AN ORGANIZED AND UNIFORM MANNER. C. REFER TO ARCHITECTURAL ELEVATIONS FOR ADDITIONAL REQUIREMENTS.WHERE THESE REQUIREMENTS DIFFER FROM THE ARCHITECTURAL PLANS, THE ARCHITECTURAL PLANS SHALL TAKE PRECEDENCE.WHERE DEVICES OR EQUIPMENT ARE SHOWN ON WALLS WHERE THE ARCHITECTURAL ELEVATION INDICATES A SURFACE OTHER THAN THE BASE PAINT FOR THE PROJECT, REQUEST CLARIFICATION ON THE MOUNTING LOCATION OF THE DEVICE OR EQUIPMENT.DEVICES AND EQUIPMENT SHALL NOT BE MOUNTED TO FEATURE WALLS AND WALLS CONSTRUCTED OF MATERIALS OTHER THAN DRYWALL WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. D. REFER TO ARCHITECTURAL ELEVATIONS FOR ALL PLUMBING FIXTURES. E. ALL DEVICES SHALL BE COORDINATED SO AS NOT TO INTERRUPT A BACK SPLASH OR MATERIAL TRANSITIONS. REFER TO ARCHITECTURAL ELEVATION TO CONFIRM DEVICE IS NOT LOCATED WITHIN TRANSITION AREA. F. PROVIDE BACKING IN WALLS WHERE WALL MOUNTED DEVICES OR EQUIPMENT ARE INSTALLED. REFER TO ARCHITECTURAL SPECIFICATIONS. SEE SPECIFICATIONS FOR CONNECTION HAND DAMPER CEILING DIFFUSER SUPPLY DUCT COLLAR FLEX DUCT MAX 4'-0" FLEX DUCT SIZE SHALL MATCH NECK SIZE CEILING MAINTAIN MIN. 3 DUCT DIAMETERS OF STRAIGHT RIGID DUCT MATCHING INLET SIZE FOR DUCT RUNOUTS LONGER THAN 5'-0", INCREASE DUCT SIZE BY 2" TRANSITION TO BOX CONNECTION SIZE ONCE WITHIN 3 INLET DIAMETERS OF BOX CONNECTION HINGED ACCESS PANEL AIR TERMINAL UNIT BUILT WITH LINER UNOBSTRUCTED ACCESS LOCATED AT ACCESS PANEL OR ABOVE CEILING TILE REHEAT COIL HI-EFFICIENCY DUCT TAKEOFF FLOW SENSOR GRID CONTROLLER BY CONTROLS CONTRACTOR SPACE BOUNDARY SEQUENCE OF OPERATION EACH ZONE HAS A TERMINAL AIR BOX WITH A HOT WATER REHEAT COIL, REHEAT COIL CONTROL VALVE, AND A DIRECT DIGITAL CONTROLLER. INSTALL A SINGLE POINT TEMPERATURE SENSOR 5'-0" DOWNSTREAM OF THE TERMINAL BOX OR BEFORE THE FIRST TAKEOFF DOWNSTREAM OF THE TERMINAL BOX. INSTALL A WALL MOUNTED THERMOSTAT TO MAINTAIN A SPACE TEMPERATURE OF 72°F (ADJUSTABLE) W ITH A DEAD BAND RANGE OF 5°F WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY TO THE ZONE IS REDUCED TO A MINIMUM. SEE DRAWINGS FOR SENSOR REQUIREMENTS. ON A CALL FOR COOLING, THE TERMINAL AIR BOX DAMPER SHALL MODULATE BETWEEN ITS MINIMUM AND MAXIMUM AIRFLOWS TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. THE REHEAT COIL CONTROL VALVE SHALL BE CLOSED. ON A CALL FOR HEATING, THE TERMINAL AIR BOX DAMPER SHALL MODULATE TO MAINTAIN ITS MINIMUM AIRFLOW. THE REHEAT COIL CONTROL VALVE SHALL MODULATE OPEN UNTIL SETPOINT IS MAINTAINED OR THE MAXIMUM HEATING DISCHARGE AIR TEMPERATURE IS REACHED. IF THE TERMINAL AIR BOX IS AT ITS MAXIMUM HEATING DISCHARGE AIR TEMPERATURE AND SETPOINT IS NOT MAINTAINED, THE TERMINAL AIR BOX DAMPER SHALL MODULATE OPEN UNTIL THE SPACE TEMPERATURE SETPOINT IS MAINTAINED OR UNTIL THE MAXIMUM HEATING CFM IS REACHED. THE REHEAT COIL CONTROL VALVE SHALL MAINTAIN THE MAXIMUM HEATING DISCHARGE AIR TEMPERATURE. FOR SPACES INDICATED ON PLANS, TERMINAL AIR BOX SHALL HAVE A "PURGE" MODE AS INDICATED BY AN OVERRIDE BUTTON AT THE THERMOSTAT. IN "PURGE" MODE, THE TERMINAL AIR BOX SHALL OPEN TO ITS MAXIMUM CFM FOR A PERIOD OF TIME REQUIRED TO ACHIEVE 99.9% CONTAMINANT REMOVAL PER THE AIRBORNE CONTAMINANT REMOVAL TABLE PROVIDED BY THE CDC. THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN SPACE TEMPERATURE THROUGHOUT "PURGE" MODE. THE DDC SYSTEM SHALL UTILIZE FEEDBACK FROM ALL TERMINAL AIR BOX POSITIONS TO RESET THE SUPPLY DUCT DIFFERENTIAL STATIC PRESSURE. IF THE HEATING WATER SYSTEM TEMPERATURE IS 5°F (ADJUSTABLE) BELOW SETPOINT ON A CALL FOR HEATING, THE TERMINAL AIR BOX SHALL REMAIN AT ITS MINIMUM AIRFLOW. GENERAL NOTES 1. TERMINAL BOX CONTROLLER SHALL HAVE A MINIMUM SERVICE CLEARANCE OF 24 INCHES AND MUST BE WITHIN 3 FEET OF CEILING. 2. WHERE MULTIPLE SPACES ARE SERVED BY A SINGLE TERMINAL AIR BOX, WIRE ALL OCCUPANCY SENSORS TO THE TERMINAL AIR BOX CONTROLLER. 3. MOUNT ALL ROOM SENSORS AT 48" ABOVE FINISHED FLOOR. COORDINATE LOCATION WITH NEARBY DEVICES SUCH AS LIGHT SWITCHES. T T T OC 1 2 3 5 4 6 7 8 9 SEQUENCE OF OPERATION EACH FAN HAS AN ISOLATION DAMPER WITH END SWITCH TO PROVE DAMPER OPEN AND CURRENT STATUS SWITCH TO PROVE FAN OPERATION. IF THE END SWITCH DOES NOT PROVE OPEN, SEND AN ALARM TO THE OPERATOR INTERFACE. IF THE CURRENT STATUS SWITCH DOES NOT PROVE OPERATION, SEND AN ALARM TO THE OPERATOR INTERFACE. FAN SHALL RUN CONTINUOUSLY. MOTORIZED DAMPER SHALL CLOSE ON LOSS OF POWER TO FAN. M AIRFLOW HUMIDIFIER DISPERSION TUBES STANDARD DUCT CONSTRUCTION GASKET FLANGED CONNECTION 1" THREADED PIPE COUPLING WELDED TO BOTTOM OF DUCT DRIP PAN TO DRAIN 1" DRAIN BY PIPING CONTRACTOR CLEANOUT BY PIPING CONTRACTOR SLOPE BOTTOM OF DUCT TOWARDS DRAING OUTLET MINIMUM 1/8" PER FOOT 6"6"24" STAINLESS STEEL, ALL WELDED SEAMS NOTES: 1. CONSTRUCT HUMIDIFIER DUCT SECTION FROM 304 STAINLESS STEEL. FULLY WELD ALL SEAMS. WELD OR FORM ON FLANGES TO MATCH STANDARD DUCTWORK FLANGES. STEEL SHALL BE A MINIMUM OF 16 GAUGE, BUT NOT LESS THAN REQUIRED FOR THE PRESSURE CLASS SPECIFIED FOR THE SYSTEM. 2. COORDINATE HUMIDIFIER LOCATION AND HOLE(S) FOR STEAM INLET TO SEAL AIR TIGHT WHERE PIPE PENETRATES DUCTWORK. 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 NO SCALE Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/25/2024 1:48:17 PM 1/25/2024 1:48:17 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt M500 01/24/2024 23289 MECHANICAL DETAILS KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . NO SCALE1 MECHANICAL EQUIPMENT MOUNTING HEIGHTS NO SCALE2 DIFFUSER CONNECTION - SIDE OF DUCT NO SCALE3TERMINAL UNIT - WATER COIL NO SCALE6VAV BOX - HOT WATER REHEAT NO SCALE5EXHAUST FAN CONTROLS... SYMBOL NAME AIR MONITORING STATION BLENDER CARBON DIOXIDE SENSOR COOLING COIL WITH TWO-WAY CONTROL VALVE DIFFERENTIAL PRESSURE SENSOR DUCT PRESSURE SENSOR DUCT TEMPERATURE SENSOR DUCT TEMPERATURE SENSOR - SHORT DX COIL FAN FAN ARRAY - ECM FAN ARRAY - VFD FILTER WITH DIFFERENTIAL PRESSURE SENSOR FIRE ALARM SYSTEM SMOKE DETECTOR FLOW SENSOR FREEZESTAT HEATING COIL WITH TWO-WAY CONTROL VALVE HEATING COIL WITH TWO-WAY CONTROL VALVE WITH PUMP HUMIDIFIER GRID INLINE CENTRIFUGAL PUMP OCCUPANCY SENSOR PARALLEL-BLADE MOTOR-OPERATED DAMPER RELATIVE HUMIDITY SENSOR TEMPERATURE SENSOR THERMOSTAT TWO-WAY MOTOR-OPERATED CONTROL VAVLE UV LIGHTS VAV BOX DAMPER COOLING ONLY VAV BOX DAMPER WITH REHEAT NO SCALE4DUCT MOUNTED HUMIDIFIER 11/08/2024 REMARKS: 1. IF NO CC IN CONTRACT, MC TO WIRE CONTROLS AND EC TO PIPE CONDUIT. 2. ALL LOW VOLTAGE WIRING OF PANELS TO BE COVERED IN MC BID, WIRING CONTRACTOR TO BE SUBCONTRACTOR TO MC. 3. INSTALLING CONTRACTOR IS RESPONSIBLE FOR FIELD ALIGNMENT SERVICES WHEN REQUIRED BY COMMON MOTOR REQUIREMENTS SPECIFICATION OR BY INDIVIDUAL EQUIPMENT SPECIFICATIONS. 4. ALL HARDWARE, SOFTWARE, EQUIPMENT, ACCESSORIES, WIRING (POWER AND SENSOR), PIPING, RELAYS, SENSORS, POWER SUPPLIES, TRANSFORMERS, AND INSTRUMENTATION REQUIRED FOR A COMPLETE AND OPERATIONAL DDC SYSTEM, BUT NOT SHOWN ON THE ELECTRICAL DRAWINGS, ARE THE RESPONSIBILITY OF THE CC. ABBREVIATIONS: MF=MINERAL FIBER(FIBERGLASS), E= ELASTOMERIC, PI = POLYISOCYANURATE REMARKS: 1. NCIIS (NATIONAL COMMERCIAL AND INDUSTRIAL INSULATION STANDARD) PLATE NUMBER REFERENCED ARE PROVIDED TO CLARIFY THE SCOPE OF INSTALLATION. INSTALL INSULATION AND ACCESSORY COMPONENTS PER APPLICABLE NCIIS AND MANUFACTURERS RECOMMENDATIONS. 2. “JACKET TYPE”IS FOR INSULATION ONLY, REFER TO SPECIFICATIONS FOR INSTALLATIONS REQUIRING ADDITIONAL FIELD APPLIED JACKETING SUCH AS METAL OR PVC. 3. INSULATE FROM EXTERIOR LOUVER OR OPENING TO 20 FEET AWAY OR TO 5 FEET PAST CONTROL OR BACKDRAFT DAMPER, WHICHEVER IS LESS. 4. INSULATE FIRE DAMPERS, SMOKE DAMPERS AND COMBINATION FIRE/SMOKE DAMPERS AS RECOMMENDED BY THE SMACNA FIRE, SMOKE AND RADIATION DAMPER INSTALLATION GUIDE FOR HVAC. 5. PROVIDE WITH 22 GAUGE CORRUGATED ALUMINUM JACKET. ABBREVIATIONS: MF = MINERAL FIBER/FIBERGLASS, E = ELASTOMERIC, CG = CELLULAR GLASS REMARKS: 1. NCIIS (NATIONAL COMMERCIAL AND INDUSTRIAL INSULATION STANDARD) PLATE NUMBER REFERENCED ARE PROVIDED TO CLARIFY THE SCOPE OF INSTALLATION. INSTALL INSULATION AND ACCESSORY COMPONENTS PER APPLICABLE NCIIS AND MANUFACTURERS RECOMMENDATIONS. 2. “JACKET TYPE”IS FOR INSULATION ONLY, REFER TO SPECIFICATIONS FOR INSTALLATIONS REQUIRING ADDITIONAL FIELD APPLIED JACKETING SUCH AS METAL OR PVC. 3. HOT WATER SYSTEM TEMPERATURES EXCEEDING 200 DEG F TO BE TREATED FOR APPROPRIATE TEMPERATURE RANGE AS LISTED UNDER LPS OR HPS. 4. INCLUDES AIR CONDITIONING CONDENSATE, P-TRAPS FOR FLOOR DRAINS/SINKS RECEIVING AIR CONDITIONING CONDENSATE OR ICE MAKER DRAIN PIPING, AND SANITARY DRAINAGE PIPING FROM ELECTRIC WATER COOLERS TO MAIN. REMARKS: 1. COORDINATE EXACT MODEL AND FRAME WITH CEILING / WALL TYPE. 2. PROVIDE REMOTE DAMPER ACTUATION IN HARD CEILINGS. 3. COORDINATE LOCATION OF GRILLES WITH ARCHITECTURAL CEILING PLANS AND ELEVATIONS. 4. WHEN INSTALLED IN A WALL, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE HORIZONTAL (PARALLEL TO THE FLOOR). WHEN INSTALLED IN A CEILING, THE BLADES FOR THESE GRILLES SHALL BE SUCH THAT THE FRONT BLADES ARE PARALLEL TO THE LONG DIMENSION OF THE GRILLE. REMARKS: 1. MAXIMUM FULL FLOW AIR PRESSURE DROP ACROSS THE BOX ASSEMBLY INCLUDING HEATING COIL SHALL BE 0.75 IN W.C. 2. MAXIMUM FULL FLOW WATER PRESSURE DROP THROUGH THE COIL SHALL BE 5 FEET. 3. MAXIMUM RADIATED SOUND LEVEL BASED ON ARI 880-98 AT 1.0 IN W.C. DIFFERENTIAL PRESSURE SHALL NOT EXCEED NC 30. 4. MAXIMUM DISCHARGE SOUND LEVEL BASED ON ARI 880-98 AT 1.0 IN W.C. DIFFERENTIAL PRESSURE SHALL NOT EXCEED NC 25. 5. PERFORMANCE OF COIL BASED ON WATER WITH ENTERING TEMPERATURE OF 180 DEG F AND A TEMPERATURE DROP OF 30 DEG F. REMARKS: 1. PROVIDE 304 STAINLESS STEEL PIPE BETWEEN STEAM GENERATOR AND HUMIDIFIER. INSTALL A WATER TIGHT SEAL TRAP AT DISCHARGE FROM HUMIDIFIER MANIFOLD. PROVIDE HIGH LIMIT HUMIDISTAT AND AIR FLOW PROVING SWITCH. 2. PROVIDE WITH 304 STAINLESS STEEL INSULATED DISPERSION TUBES. 3. PROVIDE LEGS FOR STEAM GENERATOR. 4. INSTALL MANIFOLD IN AIR HANDLING UNIT. SEAL AROUND MANIFOLD AIR TIGHT. VERIFY EXACT DIMENSIONS. 5. PROVIDE A DRAIN LINE COOLER FOR STEAM GENERATOR AND HUMIDIFIER MANIFOLD. DRISTEAM "DRAIN KOOLER" OR EQUIVALENT. 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/8" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 5/7/2024 12:08:47 PM 5/7/2024 12:08:47 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt M600 01/24/2024 23289 MECHANICAL SCHEDULES KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . COORDINATION OF WORK SCHEDULE ITEM SUPPLIER INSTALLER POWER CONTROL (4) MOTORS MC MC (3) EC CC MOTOR CONTROL CENTER EC EC EC CC EQUIPMENT MOUNTED ELECTRICAL COMPONENTS MC MC EC CC LOOSE MOUNTED ELECTRICAL COMPONENTS EC EC EC CC CONTROL RELAYS, TRANSFORMERS, POWER MC EC EC (4) CC 120V THERMOSTATS MC MC MC CC (1) VARIABLE SPEED DRIVES MC MC EC CC TERMINAL BOX CONTROLS MC MC EC (4) CC PE/EP SWITCHES, SOLENOID VALVES, ACTUATORS CC CC EC (4) CC SMOKE DAMPERS MC MC EC EC MEDICAL GAS ALARM WIRING MC MC EC MC (2) DIFFUSER, REGISTER, AND GRILLE SCHEDULE MARK IMAGE DESCRIPTION MAX S.P. MATERIAL FINISH FACE SIZE NECK SIZE AIRFLOW MANUFACTURER MODEL REMARKSLENGTH WIDTH D1 PLAQUE FACE STYLE SUPPLY DIFFUSER 0.10 in-wg STEEL PAINT, WHITE 24" 24" 6" 8" 10" 12" 14" 0 - 120 121 - 210 211 - 320 321 - 470 471 - 640 TITUS OMNI 1-4 G10 SINGLE DEFLECTION RETURN GRILLE 0.10 in-wg STEEL PAINT, WHITE 6" 10" 12" 12" 12" 18" 24" 24" 24" 24" 6" 6" 8" 10" 12" 12" 12" 20" 24" 36" 6"x6" 10"x6" 12"x8" 12"x10" 12"x12" 18"x12" 24"x12" 24"x20" 24"x24" 24"x36" 0 - 100 101 - 200 201 - 300 301 - 400 401 - 480 481 - 700 701 - 910 911 - 1500 1501 - 1700 1701 - 2400 TITUS 350RL/SL 1-4 GE12 EGG CRATE EXHAUST GRILLE 0.10 in-wg ALUMINUM PAINT, WHITE 24" 12" 22"x10" 0-955 TITUS 50F 1-4 DUCT AND PLENUM INSULATION SCHEDULE DUCT SYSTEM TYPE INSULATION JACKET TYPE (2) NCIIS PLATE NUMBER (1)REMARKSTYPE INSTALLED R VALUE MINIMUM DENSITY LB/SF SUPPLY AIR (CONCEALED) MF BLANKET 6 0.75 FSK 3-100 4,5 RETURN AIR (CONCEALED) MF BLANKET 6 0.75 FSK 3-100 4,5 RELIEF/EXHAUST AIR (NON HEAT RECOVERY APPLICATIONS) (CONCEALED) MF BLANKET 6 0.75 FSK 3-100 3,4,5 HVAC PIPING INSULATION SCHEDULE PIPING SYSTEM FLUID TEMP. RANGE DEG. F. THICKNESS IN INCHES FOR PIPE SIZES THROUGH SIZE LISTED TYPE JACKET TYPE (2) NCIIS PLATE NUMBER (1)REMARKS<1 1 - 1.25 1.5 - 3 4 - 6 >/= 8 INDOOR HOT WATER 141 - 200 1.5 1.5 2 2 2 MF ASJ-SSL 1-100 3 INDOOR CONDENSATE AND EQUIPMENT DRAINS BELOW 60 0.5 0.5 0.5 0.5 0.5 MF, E ASJ-SSL 1-100, 1-200 4 VARIABLE VOLUME BOX - HOT WATER MARK AIRFLOW [CFM] BOX INLET [IN] LEAVING AIR TEMP COIL CAPACITY [MBH] COIL FLOW [GPM]MANUFACTURER MODEL REMARKS CONNECTED TERMINAL MAXIMUM MINIMUM COOLING [°F] HEATING [°F] (N)VAV PH3.2 2400 3000 800 16 55 90 109.3 7.4 GPM ENVIRO-TEC SDL 1-5 (N)VAV PH3.3 700 1080 250 10 55 90 39.4 2.7 GPM ENVIRO-TEC SDL 1-5 1 05/07/2024 NM RFI 1 HUMIDIFIER SCHEDULE MARK SERVICE STEAM GENERATOR HUMIDIFIER MANIFOLD REMARKS ELECTRIC ELECTRICAL DATA CFM STEAM CAPACITY [LB / HR] DUCT SIZE ABSORPTION DISTANCE MAX [IN]MANUFACTURER MODELKW DISCONNECT BY VOLTAGE PHASE MANUFACTURER MODEL H-1 NUC MED ROOM 21 E.C. 480 V 3 DRISTEEM RX-63-1 2400 48.37 26x12 16" DRISTEEM ULTRASORB LV 1,2,3,4,5 H-2 CONTROL ROOM 6 E.C. 480 V 3 DRISTEEM RX-18-1 700 14.11 12x12 6" DRISTEEM ULTRASORB LV 1,2,3,4,5 1 11/08/2024 T T T H H 19 Q P O P.9 AA 19.4 20 21 21.4 22 22.8 23 24 25 25.4 N.M .TECH 1612 N.M. / CT IMAGING 1622 STORAGE (EXISTING) 1809 GENERAL COUNSELOR (EXISTING) X74 CEO OFFICE (EXISTING) X75 ADMIN ASSISTANT (EXISTING) X70 DIRECTOR OF MARKETING (EXISTING) X72 N.M. WAITING (EXISTING) 1614 CHECK-IN/ WAITING (EXISTING) 1601 PATIENT TOILET (EXISTING) 1625 LOCKERS (EXISTING) 1610 HALL (EXISTING) X101 STRESS TEST (EXISTING) 1611 VAV PH4.1 12 x 1 2 S A 10ø SA 16ø SA 18 ø S A 250 D1 200 D1 250 D1 400 D1 400 D1 400 D1 400 D1 400 D1 400 D1 600 G10 600 G10 500 G10 600 G10 600 G10 200 GE12 1 2 (N)VAV PH3.3 (N)VAV PH3.2 260 (E)G 3 18 x 1 0 R A 24 x 1 4 R A 24x14 RA 26x12 SA (E)38x38 RA(E)38x38 RA (E)34x16 RA 30x16 RA H-1 H-2 1 1 4 4 1 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/4" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 5/7/2024 12:08:48 PM 5/7/2024 12:08:48 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt MH201 01/24/2024 23289 NEW FLOOR PLAN - DUCTWORK KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1. MECHANICAL SYMBOLS AND ABBREVIATIONS SHEET GENERAL NOTES APPLY TO ALL SHEETS. 2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS. 3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED. 4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM THIS WORK. 5. MECHANICAL WORK IS EFFECTING AREAS OUTSIDE OF THE ARCHITECTURAL SCOPE OF WORK, MECHANICAL CONTRACTOR SHALL COORDINATE AREAS OF DISRUPTION AND IMPACT WITH OWNER AND GENERAL CONTRACTOR PRIOR TO BEGINING WORK. SHEET NOTES: 1. CONNECT NEW 18" DIAMETER SUPPLY MAIN TO RTU-11 SUPPLY OUTPUT. 2. CONNECT NEW EXHAUST GRILLE TO EXISTING EXHAUST FAN ABOVE CEILING. CONFIRM EXHAUST FAN IS IN GOOD WORKING CONDITION. REPORT ANY ISSUES WITH FAN OPERATION TO ARCHITECT AND ENGINEER. 3. CONNECT NEW RETURN MAIN TO RTU-11 RETURN DUCTWORK. 4. HUMIDIFIER MANIFOLD LOCATION. GENERAL NOTES: 1/4" = 1'-0"1 LEVEL 01 - NEW PLAN - MECHANICAL 1 05/07/2024 NM RFI 1 11/08/2024 19 Q P O P.9 AA 19.4 20 21 21.4 22 22.8 23 24 25 25.4 N.M .TECH 1612 N.M. / CT IMAGING 1622 STRESS TEST (EXISTING) 1611 HALL (EXISTING) X101 CHECK-IN/ WAITING (EXISTING) 1601 PATIENT TOILET (EXISTING) 1625 LOCKERS (EXISTING) 1610 CHECK-IN/ WAITING (EXISTING) 1601 N.M. WAITING (EXISTING) 1614 DIRECTOR OF MARKETING (EXISTING) X72 STORAGE (EXISTING) 1809 GENERAL COUNSELOR (EXISTING) X74 ADMIN ASSISTANT (EXISTING) X70 CEO OFFICE (EXISTING) X75 (E)CWR (E)CWS (E)HWR (E)HWS (E)3/4" HWS (E)3/4" HWR 1 (N)VAV PH3.2 (N)VAV PH3.3 H-2 H-1 2 2 2 3 3 1 1 1 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/4" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 5/7/2024 12:08:49 PM 5/7/2024 12:08:49 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt MP201 01/24/2024 23289 NEW FLOOR PLAN - HYDRONIC PIPING KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/4" = 1'-0"1 LEVEL 01 - NEW PLAN - PIPING 1. MECHANICAL SYMBOLS AND ABBREVIATIONS SHEET GENERAL NOTES APPLY TO ALL SHEETS. 2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS. 3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED. 4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM THIS WORK. SHEET NOTES: 1. CONNECT HWS/R PIPING TO NEW VAV. 2. ROUTE CONDENSATE AND HUMIDIFIER DRAINAGE TO SINK TAIL. 3. HUMIDIFIER MANIFOLD LOCATION. 1-1/2" STEAM PIPE CONNECTION BETWEEN STEAM GENERATOR AND ASSOCIATED MANIFOLD. GENERAL NOTES: 1 05/07/2024 NM RFI 1 1 11/08/2024 C.O. C.O. PLUMBING SYMBOLS SYMBOL DESCRIPTION ADDITIONAL REMARKS PIPING -SINGLE DASH INDICATES DOMESTIC COLD WATER -DOUBLE DASH INDICATES DOMESTIC HOT WATER -TRIPLE DASH INDICATES HOT WATER CIRCULATING -SOLID INDICATES SANITARY ABOVE FLOOR -CONTINUOUS DASHED INDICATES VENT -LONG DASHED LINES INDICATE SANITARY BELOW FLOOR NUMBER INDICATES NOMINAL DIAMETER IN INCHES, LETTER(S) INDICATES SYSTEM. REFER TO ABBREVIATIONS FOR SYSTEM TYPE. ROOF DRAIN TAG INDICATES DRAIN SIZE IN INCHES AND AREA OF ROOF DRAINED IN SQUARE FEET REFER TO PLUMBING FIXTURE SCHEDULE FOR TYPE.#"RD # SF WALL DISCHARGE (DOWNSPOUT NOZZLE) TAG INDICATES DRAIN SIZE IN INCHES AND AREA OF ROOF DRAINED IN SQUARE FEET REFER TO PLUMBING FIXTURE SCHEDULE FOR TYPE.#"DSN # SF FD-#FLOOR DRAIN REFER TO PLUMBING FIXTURE SCHEDULE FOR TYPE. CLEANOUT CIRCLE INDICATES UP TO FLOOR OR WALL CLEANOUT. LINE INDICATES END OF PIPE CLEANOUT LOCATED ABOVE A CEILING. DOUBLE GRADE CLEANOUT REFER TO DETAILS FOR ADDITIONAL REQUIREMENTS. SANITARY WYE AND 1/8TH BEND FITTINGS OR COMBINATION FITTING SANITARY TEES MAY BE USED IN VERTICAL PIPING WHERE PERMITTED BY CODE. ABBREVIATION PLUMBING ABBREVIATIONS DESCRIPTION CHEMICAL VENTCV CHEMICAL WASTECW BOTTLE/GLASS FILLERBF DOMESTIC HOT WATERDHW DOMESTIC HOT WATER CIRCULATIONDHWC NOT ALL ABBREVIATIONS APPLY TO THIS SET OF DOCUMENTS BACK FLOW PREVENTERBFP BATH TUBBT COMPRESSED AIR (NON-MEDICAL)CA CONDENSATE DRAINCD CLEANOUTCO CONDENSATE PUMPCP CLINICAL SINKCS DOMESTIC COLD WATERDCW DRINKING FOUNTAINDF DOUBLE GRADE CLEANOUTDGCO DEIONIZED WATERDI DEIONIZED WATER CIRCULATINGDIC DEIONIZED HOT WATERDIH DEIONIZED HOT WATER CIRCULATINGDIHC DISTILLED WATERDIS DISTILLED WATER CIRCULATINGDISC DIALYSIS WATER RETURNDR DIALYSIS WATER SUPPLYDS DRAIN TILEDT EMERGENCY EYE WASHEEW EMERGENCY SHOWERES EMERGENCY SHOWER AND EYE WASH COMBOESEW EXPANSION TANKET ELECTRIC WATER COOLEREWC ENTERING WATER TEMPERATUREEWT FILTERF FLOOR CLEANOUTFCO FLOOR DRAINFD FLOOR SINKFS NATURAL GASG GRADE CLEANOUTGCO GREASE VENTGV GREASE WASTEGW DOWN SPOUT NOZZLEDSN ABBREVIATION DESCRIPTION LAVATORYL PROPANELPG LEAVING WATER TEMPERATURELWT BTU (1000'S)MBH MOP SINKMS NORMALLY CLOSEDNC NORMALLY OPENNO NON-POTABLE COLD WATERNPCW POST INDICATOR VALVEPIV PRESSURE REDUCING VALVEPRV ROOF DRAINRD REVERSE OSMOSIS WATERRO RPZ S REDUCED PRESSURE ZONE (BACK FLOW PREVENTER) SINK SANITARY SEWERSAN DOMESTIC SOFT COLD WATERSCW DOMESTIC SOFT HOT WATERSHW DOMESTIC SOFT HOT WATER CIRCULATINGSHWC SEWAGE EJECTORSE SHOWERSH STORM OVERFLOWSO SUMP PUMPSP SERVICE SINKSS STORM SEWERST TEMPERATURETEMP URINALUR VENTV VENT THROUGH ROOFVTR WB WC WALL BOX WATER CLOSET WALL CLEANOUTWCO HUB DRAINHD WATER HEATERWH WATER SOFTENERWS HORSEPOWERHP WPD YCO WATER PRESSURE DROP YARD CLEANOUT HOSE BIBHB NON-POTABLE HOT WATERNPHW INVERT ELEVATIONIE MEDICAL GAS SYMBOLS SYMBOL DESCRIPTION ADDITIONAL REMARKS ALARM / CONTROL PANEL (MASTER OR AREA) ZONE VALVE BOX # OF CIRCLES/PIPES INDICATES NUMBER OF VALVES; ARROW INDICATES VALVE ACCESS SIDE REFER TO MOUNTING HEIGHTS DETAIL FOR MOUNTING ELEVATION REFER TO ABBREVIATIONS FOR TYPE REFER TO MOUNTING HEIGHTS DETAIL FOR MOUNTING ELEVATION EMERGENCY OXYGEN CONNECTION REFER TO MOUNTING HEIGHTS DETAIL FOR MOUNTING ELEVATION ISOLATION VALVE REFER TO SPECIFICATIONS FOR TYPE BASED ON SIZE AND SYSTEM. LOCATE ABOVE CEILING AND PROVIDE WITH LOCKABLE HANDLE. SENSING LOCATION XXXX MEDICAL GAS OUTLET REFER TO ABBREVIATIONS FOR GAS TYPE. PROVIDE BRACKET WITH EACH VACUUM OUTLET. REFER TO MOUNTING HEIGHTS DETAILS FOR MOUNTING ELEVATION. COORDINATE WITH ARCHITECTURAL DIVISION. ABBREVIATION LABORATORY AND MEDICAL GAS ABBREVIATIONS DESCRIPTION MEDICAL COMPRESSED AIRA MEDICAL COMPRESSED AIR INTAKEAI AREA ALARM PANELAAP NOT ALL ABBREVIATIONS APPLY TO THIS SET OF DOCUMENTS COMPRESSED AIR (NON-MEDICAL)CA MEDICAL CARBON DIOXIDEC DENTAL AIRDA DENTAL AIR INTAKEDAI DENTAL VACUUMDV DENTAL VACUUM EXHAUSTDVE EMERGENCY OXYGEN CONNECTIONEOC MEDICAL HELIUMHE HORSEPOWERHP INSTRUMENT AIRIA INSTRUMENT AIR INTAKEIAI LABORATORY AIR LA LABORATORY AIR INTAKELAI ABBREVIATION DESCRIPTION LABORATORY VACUUMLV LABORATORY VACUUM EXHAUSTLVE MEDICAL AIR COMPRESSORMAC MASTER ALARM PANELMAP MEDICAL VACUUM PUMPMVP MEDICAL NITROGENN MEDICAL NITROUS OXIDENO MEDICAL OXYGENO PRESSURE REDUCING VALVEPRV MEDICAL VACUUMV MEDICAL VACUUM EXHAUSTVE VALVE BOXVB MEDICAL WASTE ANESTHESIA GAS DISPOSALWAG WATER COLUMNWC PLUMBING GENERAL NOTES: 1. THE CONTRACTOR SHALL BE RESPONSIBLE TO DESIGN AND INSTALL A COMPLETE FIRE PROTECTION SYSTEM WITHIN THE PROJECT AREA. THIS INCLUDES, BUT IS NOT LIMITED TO, RELOCATING PIPING TO ACCOMMODATE NEW CONSTRUCTION REQUIREMENTS, REVISING SPRINKLER HEAD LAYOUTS, AND COMPLYING WITH NFPA-13 AND DIVISION 21 SPECIFICATION REQUIREMENTS. 2. THIS PROJECT AREA IS WITHIN AN EXISTING FACILITY CONNECTED TO CITY DOMESTIC COLD WATER AND IS PROTECTED BY AN EXISTING REDUCED PRESSURE BACKFLOW PREVENTER. 3. THE EXISTING DOMESTIC HOT WATER SYSTEM IS CONNECTED TO WATER HEATERS HEATING THE WATER TO 140 DEGREES, IT IS ROUTED TO AN ASSE 1017 THERMOSTATIC MIXING VALVE, DELIVERING THE HOT WATER PROVIDED TO THE PROJECT AREA PLUMBING FIXTURES AT 110 DEGREES. THE EXISTING HOT WATER SYSTEM HAS A RECIRCULATING SYSTEM WITH A CIRCULATING PUMP. 4. THIS IS AN EXISTING BUILDING WITH AN EXISTING DOMESTIC WATER SYSTEM THAT IS BEING MODIFIED TO REPLACE AND/OR INSTALL NEW PLUMBING FIXTURES. HOT AND COLD WATER DEMANDS HAVE BEEN CALCULATED TO VERIFY THE EXISTING SYSTEM AND WATER HEATER EQUIPMENT IS ADEQUATE TO MEET THE NEEDS OF THE PLUMBING FIXTURES. THE USE OF A DIVERSITY FACTOR FOR CAPACITY HAS BEEN INCLUDED IN THE DOMESTIC WATER DESIGN. 5. SEE ARCHITECTURAL SERIES SHEETS FOR OCCUPANT LOAD FOR PLUMBING FIXTURES. 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 As indicated Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/25/2024 1:48:29 PM 1/25/2024 1:48:29 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt P000 01/24/2024 23289 PLUMBING SYMBOLS AND ABBREVIATIONS KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 11/08/2024 19 Q P O P.9 P.9 AA 19.4 20 21 21.4 22 22.8 23 24 25 25.4 CHECK-IN/ WAITING (EXISTING) 1601 HALL (EXISTING) X101 CHECK-IN/ WAITING (EXISTING) 1601 N.M. WAITING (EXISTING) 1614 STRESS TEST (EXISTING) 1611 GENERAL COUNSELOR (EXISTING) X74 DIRECTOR OF MARKETING (EXISTING) X72 STORAGE (EXISTING) 1809 CEO OFFICE (EXISTING) X75 (E)1/2" O (E)3/4" V (E)1/2" DCW (E)3/4" DHWC (E)1/2" O(E)1/2" A (E)1 1/4" V 3/ 4 " (E)3/4" DHWC (E)2" DCW(E)1 1/4" DHW (E ) 3 / 4 " D C W (E ) 3 / 4 " D H W (E ) 1 1 / 4 " V (E ) 1 / 2 " A (E ) 1 / 2 " O 1/ 2 " O 3/ 4 " V (E)2" DCW(E)1 1/4" DHW (E)3/4" DHWC V O 1 3 2 4 5 (E)4" SAN (E)2" SAN (E)3/4" DHWC (E)4" SAN 1 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/4" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 5/7/2024 12:08:50 PM 5/7/2024 12:08:50 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt P101 01/24/2024 23289 PLUMBING & MEDICAL GAS DEMOLITION KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/4" = 1'-0"1 LEVEL 01 - DEMO - PLUMBING & MED GAS 1. MECHANICAL SYMBOLS AND ABBREVIATIONS SHEET GENERAL NOTES APPLY TO ALL SHEETS. 2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS. 3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED. 4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM THIS WORK. 5. SANITARY PIPING IS ROUTED IN CEILING OF THE FLOOR BELOW, TYPICAL. SHEET NOTES: 1. SALVAGE EXISTING SINK FOR RELOCATION. REMOVE ASSOCIATED PIPING IN WALL TO ABOVE CEILING. PREPARE PLUMBING PIPE ABOVE CEILING FOR CONNECTION TO NEW SINK LOCATION. 2. REMOVE MED GAS WALL OUTLETS. REMOVE ASSOCIATED MED GAS PIPING BACK TO MAIN ABOVE CEILING. 3. PREPARE MED GAS PIPING FOR NEW CONNECTION. 4. EXISTING MED GAS OUTLETS TO REMAIN. 5. REMOVE EXISTING SINK. REMOVE ASSOCIATED PIPING AS SHOWN ON PLANS. GENERAL NOTES: 1 05/07/2024 NM RFI 1 11/08/2024 MINIMUM 6" (TYP) MINIMUM 24"MINIMUM 24"APPROX. 15" OXYGEN MEDICAL AIR VACUUM (SLIDE) (SLIDE)NOTES: 1. REFER TO DRAWINGS AND SPECIFICATIONS FOR FURTHER INFORMATION. 2. EXACT SLIDE LOCATION TO BE DETERMINED BY OWNER. CONTRACTOR TO PROVIDE MOCK-UP FOR VISUAL APPROVAL OF SLIDE LOCATION BY OWNER. 3. COORDINATE LAYOUT WITH ARCHITECTURAL ELEVATIONS AND ELECTRICAL DEVICES. NOTES: 1. REFER TO DRAWINGS FOR AUTOMATIC FLOW CONTROL FLOW RATE AND PIPE SIZE. FROM DHW TO DHWC TYPICAL SINKTYPICAL CLINIC SERVICE SINK 2" V 4" CS 1-1/2" V 1-1/2" S 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 As indicated Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/25/2024 1:48:31 PM 1/25/2024 1:48:31 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt P500 01/24/2024 23289 PLUMBING DETAILS KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . NO SCALE1MEDICAL GAS OUTLET INSTALLATION REQUIREMENTS NO SCALE2DOMESTIC HOT WATER CIRCULATION CONNECTION NO SCALE3TYPICAL PLUMBING ISOMETRICS 11/08/2024 ABBREVIATIONS: MF = MINERAL FIBER/FIBERGLASS, E = ELASTOMERIC, CG = CELLULAR GLASS REMARKS: 1. NCIIS (NATIONAL COMMERCIAL AND INDUSTRIAL INSULATION STANDARD) PLATE NUMBER REFERENCED ARE PROVIDED TO CLARIFY THE SCOPE OF INSTALLATION. INSTALL INSULATION AND ACCESSORY COMPONENTS PER APPLICABLE NCIIS AND MANUFACTURERS RECOMMENDATIONS. 2. “JACKET TYPE”IS FOR INSULATION ONLY, REFER TO SPECIFICATIONS FOR INSTALLATIONS REQUIRING ADDITIONAL FIELD APPLIED JACKETING SUCH AS METAL OR PVC. 3. INCLUDES AIR CONDITIONING CONDENSATE, P-TRAPS FOR FLOOR DRAINS/SINKS RECEIVING AIR CONDITIONING CONDENSATE OR ICE MAKER DRAIN PIPING, AND SANITARY DRAINAGE PIPING FROM ELECTRIC WATER COOLERS TO MAIN. 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 NO SCALE Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/25/2024 1:48:31 PM 1/25/2024 1:48:31 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt P600 01/24/2024 23289 PLUMBING SCHEDULES KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . PLUMBING FIXTURE SCHEDULE MARK TYPE DESCRIPTION PIPING CONNECTIONS COLD WATER HOT WATER WASTE VENT S-1 SINK WALL-MOUNTED HANDWASH SINK. BASIN: JUST A-33338 OR SIMILAR. FAUCET: ZURN Z812A4-XL OR SIMILAR. 1/2" 1/2" 2" 1-1/2" PLUMBING PIPING INSULATION SCHEDULE PIPING SYSTEM FLUID TEMP. RANGE DEG. F. THICKNESS IN INCHES FOR PIPE SIZES THROUGH SIZE LISTED TYPE JACKET TYPE (2) NCIIS PLATE NUMBER (1)REMARKS<1 1 - 1.25 1.5 - 3 4 - 6 >/= 8 INDOOR HOT WATER AND HOT WATER RECIRC 141 - 200 1.5 1.5 2 2 2 MF ASJ-SSL 1-100 INDOOR HOT WATER AND HOT WATER RECIRC 105 - 140 1 1 1.5 1.5 1.5 MF ASJ-SSL 1-100 INDOOR COLD WATER 40 - 60 0.5 0.5 1 1 1 MF, E ASJ-SSL 1-100, 1-200 INDOOR CONDENSATE AND EQUIPMENT DRAINS BELOW 60 0.5 0.5 0.5 0.5 0.5 MF, E ASJ-SSL 1-100, 1-200 3 11/08/2024 19 Q P O P.9 AA 19.4 20 21 21.4 22 22.8 23 24 25 25.4 CHECK-IN/ WAITING (EXISTING) 1601 HALL (EXISTING) X101 LOCKERS (EXISTING) 1610 PATIENT TOILET (EXISTING) 1625 DIAGNOSTICS (EXISTING) 1603 STRESS TEST (EXISTING) 1611 CHECK-IN/ WAITING (EXISTING) 1601 N.M. WAITING (EXISTING) 1614 N.M. / CT IMAGING 1622 N.M .TECH 1612 CONTRAST MEDIA PREP AREA-2 1613-2 STORAGE (EXISTING) 1809 DIRECTOR OF MARKETING (EXISTING) X72 ADMIN ASSISTANT (EXISTING) X70 GENERAL COUNSELOR (EXISTING) X74 CEO OFFICE (EXISTING) X75 3/4" V 1/2" O 1/2" O 1/2" A 1 1/4" V (E) ZV O V 1 2 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC -MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/4" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/25/2024 1:48:33 PM 1/25/2024 1:48:33 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt PG201 01/24/2024 23289 NEW FLOOR PLAN - MEDICAL GAS KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/4" = 1'-0"1 LEVEL 01 - NEW PLAN - MEDICAL GAS 1. MECHANICAL SYMBOLS AND ABBREVIATIONS SHEET GENERAL NOTES APPLY TO ALL SHEETS. 2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS. 3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED. 4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM THIS WORK. SHEET NOTES: 1. NEW MEDICAL GAS WALL OUTLETS. 2. INSTALL NEW MED GAS ALARM PANEL TO DUPLICATE MED GAS ALARM INFORMATION FROM EXISTING PANEL. GENERAL NOTES: 11/08/2024 19 Q P O P.9 AA 19.4 20 21 21.4 22 22.8 23 24 25 25.4 CHECK-IN/ WAITING (EXISTING) 1601 CHECK-IN/ WAITING (EXISTING) 1601 N.M. WAITING (EXISTING) 1614 STRESS TEST (EXISTING) 1611 LOCKERS (EXISTING) 1610 PATIENT TOILET (EXISTING) 1625 HALL (EXISTING) X101 N.M. / CT IMAGING 1622 N.M .TECH 1612 CONTRAST MEDIA PREP AREA-2 1613-2 STORAGE (EXISTING) 1809 GENERAL COUNSELOR (EXISTING) X74 CEO OFFICE (EXISTING) X75 DIRECTOR OF MARKETING (EXISTING) X72 3/4" DHWC 3/4" DHW 1/2" DCW 3/ 4 " D H W C 3/ 4 " D C W 3/ 4 " D H W 2" DCW 1 1/4" DHW3/4" DHWC 1 S-1 (E)4" SAN (E)4" SAN (E)2" SAN H-1 H-2 2 3 3/ 4 " D H W 1/ 2 " D C W FS-1 4 1 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/4" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 5/7/2024 12:08:51 PM 5/7/2024 12:08:51 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt PP201 01/24/2024 23289 NEW FLOOR PLAN - PLUMBING KRB JJW © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 1/4" = 1'-0"1 LEVEL 01 - NEW PLAN - PLUMBING 1. MECHANICAL SYMBOLS AND ABBREVIATIONS SHEET GENERAL NOTES APPLY TO ALL SHEETS. 2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS. 3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED. 4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM THIS WORK. 5. SANITARY PIPING IS ROUTED IN CEILING OF THE FLOOR BELOW, TYPICAL. SHEET NOTES: 1. RELOCATED SINK LOCATION. 2. 1/2" SOFTENED DOMESTIC HOT WATER SHALL SERVE STEAM GENERATORS. 3. ROUTE HUMIDIFIER DRAINAGE TO DRAIN COOLER AT FLOOR DRAIN. 1/2" DOMESTIC COLD WATER SHALL SERVE HUMIDIFIER DRAIN COOLERS. 4. STEAM GENERATORS H-1 AND H-2 SHALL BE WALL MOUNTED VERTICALLY STACKED AND CENTERED IN THE NEW CLOSET IN NM WAITING. CONTRACTOR SHALL CONFIRM MANUFACTURER REQUIRED CLEARANCES ARE MET WHEN CLOSET DOOR IS OPEN. GENERAL NOTES: 1 05/07/2024 NM RFI 1 11/08/2024 ELECTRICAL ABBREVIATIONS ABBREVIATION DESCRIPTION REFER TO OTHER SCHEDULES AND NOTES FOR ADDITIONAL ABBREVIATIONS. MOUNTING HEIGHT TO CENTERLINE (ABOVE FINISHED FLOOR) AMPERE AMPERE FRAME ABOVE FINISHED FLOOR ALUMINUM AMPERE TRIP CEILING CIRCUIT BREAKER CORRELATED COLOR TEMPERATURE COPPER DEMO EXISTING FUSE FULL LOAD AMPS GROUND FAULT CIRCUIT INTERRUPTER HORSEPOWER KILOAMPERE INTERRUPTING CAPACITY KILOVOLT AMPERE KILOWATT MAXIMUM MINIMUM CIRCUIT AMPS MAIN CIRCUIT BREAKER MINIMUM MAIN LUGS ONLY NON-FUSED POLES PARTIAL RELOCATE SHORT CIRCUIT CURRENT RATING SURGE PROTECTIVE DEVICE SHUNT TRIP TYPICAL UNLESS NOTED OTHERWISE WIRE WEATHER RESISTANT TRANSFORMER ##" A AF AFF AL AT C CB CCT CU D E F FLA G, GFCI HP KAIC KVA KW MAX MCA MCB MIN MLO NF P PART R SCCR SPD ST TYP UNO W WR XFMR A. BRANCH CIRCUITS WITH A TOTAL LENGTH LONGER THAN 75' SHALL UTILIZE #10 AWG CONDUCTORS. RECEPTACLE BRANCH CIRCUITS WITH A TOTAL LENGTH LONGER THAN 150' SHALL UTILIZE #8 AWG CONDUCTORS. B. FOR ALL CONDUIT AND OTHER ITEMS PENETRATING A FIRE RATED WALL, PROVIDE UL LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM THAT IS SPECIFIC TO THE WALL CONSTRUCTION ASSEMBLY AND COMPLIANT WITH ASTM E814. INSTALL SYSTEM IN STRICT COMPLIANCE WITH THE FIRE STOPPING MANUFACTURER’S U.L. APPROVED DETAIL. WHERE EXISTING WALLS ARE BEING UPGRADED TO FIRE RATED WALLS OR THE FIRE RATING IS BEING MODIFIED, PROVIDE U.L. LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM FOR ALL NEW AND EXISTING PENETRATIONS. REFER TO THE ARCHITECTURAL LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED WALLS. C. NEW ROOF MOUNTED EQUIPMENT SHALL BE BONDED TO EXISTING BUILDING LIGHTNING PROTECTION SYSTEM IF ONE EXISTS. PROVIDE AIR TERMINALS ON TOP OF EQUIPMENT AND BOND TO EXISTING SYSTEM PER NFPA 780 AND UL 96A REQUIREMENTS. PROVIDE UL INSPECTION AND/OR LPI SYSTEM INSPECTION AS REQUIRED TO OBTAIN UL MASTER LABEL RECERTIFICATION, UL MASTER LABEL AND/OR LPI SYSTEM CERTIFICATE. D. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER. E. NEW WIRING DEVICES AND ASSOCIATED COVERPLATES SHALL MATCH EXISTING FINISH OF SIMILAR INSTALLED DEVICES. F. THE SELECTED EQUIPMENT AIC RATINGS ARE BASED ON THE IMPEDANCES FOR CONDUCTORS AND TRANSFORMERS USED IN THE CALCULATIONS. IF DIFFERENT EQUIPMENT OR DIFFERENT CONFIGURATIONS ARE SELECTED FOR INSTALLATION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATELY RATED EQUIPMENT THAT MEETS APPLICABLE SELECTIVE COORDINATION GOALS AND PROVIDES SIMILAR INCIDENT ENERGY RISK OF ARC FLASH HAZARDS. G. PROVIDE AN INSULATED CONTINUOUS COPPER CONDUCTOR, NOT SMALLER THAN #10, TO BOND ALL NORMAL AND ESSENTIAL ELECTRICAL SYSTEM PANELBOARDS TOGETHER THAT SERVE THE SAME INDIVIDUAL PATIENT VICINITY AS DEFINED IN NEC 517.14. H. ALL CRITICAL AND LIFE SAFETY BRANCH CIRCUITS, INCLUDING LIGHTING AND WALL RECEPTACLES, SHALL BE MECHANICALLY PROTECTED PER NEC 517.31(C)(3). NON-FLEXIBLE RACEWAY SHALL BE USED FOR CRITICAL AND LIFE SAFETY BRANCH CIRCUITS, EXCEPT THAT THE FINAL CONNECTION TO VIBRATING EQUIPMENT OR LIGHT FIXTURES IF THE TOTAL LENGTH OF FLEXIBLE RACEWAY IS 6' OR LESS ACROSS THE ENTIRE CIRCUIT LENGTH. I. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO INDEPENDENTLY SUPPORT ALL EXISTING TO REMAIN CABLING. (GENERAL NOTES SHALL APPLY TO ALL SHEETS) ELECTRICAL GENERAL NOTES: LEGEND: (LOW VOLTAGE COORDINATION LEGEND) CF: CONTRACTOR FURNISHED CI: CONTRACTOR INSTALLED OF: OWNER FURNISHED OI: OWNER INSTALLED REMARKS: (LOW VOLTAGE COORDINATION LEGEND) 1. FIRE ALARM IS AN EXTENSION OF AN EXISTING SYSTEM. NEW DEVICES SHALL FUNCTION AS AN EXTENSION OF THE EXISTING SYSTEM. GENERAL NOTES: (LOW VOLTAGE COORDINATION LEGEND) A. REFER TO SYMBOL LEGENDS AND SPECIFICATIONS FOR SPECIFIC REQUIREMENTS. B. COORDINATE ROUGH-IN REQUIREMENTS WITH FINAL EQUIPMENT SELECTION FOR ALL SYSTEMS. C. COORDINATE ROUGH-IN REQUIREMENTS WITH OWNER FOR OWNER FURNISHED SYSTEMS. D. CONDUITS SHALL ROUTE CONCEALED INSIDE WALL TO ABOVE NEAREST ACCESSIBLE CEILING SPACE, UNLESS OTHERWISE INDICATED. E. WHERE CABLING IS CONTRACTOR FURNISHED AND CONTRACTOR INSTALLED, TERMINATE AND TEST ALL CABLING PER SPECIFICATION. 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 NO SCALE Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/23/2024 4:04:41 PM 1/23/2024 4:04:41 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt E000 01/24/2024 23289 ELECTRICAL SYMBOLS AND ABBREVIATIONS KDD RJA © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . ELECTRICAL FIXTURE SYMBOLS PLAN SYMBOL NAME RECEPTACLE - DOUBLE DUPLEX - CONV RECEPTACLE - DOUBLE DUPLEX - EMERGENCY (RED) - CONV RECEPTACLE - DOUBLE DUPLEX - EMERGENCY (RED) - CONV - GFCI RECEPTACLE - DUPLEX - CONV RECEPTACLE - DUPLEX - CONV - GFCI RECEPTACLE - DUPLEX - EMERGENCY (RED) - CONV ELECTRICAL FIXTURE SYMBOL LEGEND PLAN SYMBOL NAME DESCRIPTION EMERGENCY POWER OFF SWITCH GENERAL: PROVIDE EMERGENCY POWER OFF (EPO) SWITCH AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH TYPE, AT APPROXIMATE LOCATIONS INDICATED ON PLANS. REFER TO PLANS FOR EPO SWITCH DESIGNATION. MOUNT AT 48" AFF, UNLESS OTHERWISE INDICATED. PROVIDE ELECTRICAL COMPONENTS FOR A COMPLETE SYSTEM, INCLUDING ALL NECESSARY RELAYS, TRANSFORMERS, AND SHUNTING DEVICES. COORDINATE BACK BOX AND CONDUIT REQUIREMENTS WITH MANUFACTURER. TYPE ‘EPO’, EMERGENCY POWER OFF SWITCH: PROVIDE STI (SAFETY TECHNOLOGY INTERNATIONAL, INC) MODEL SS2-271PO-EN SURFACE MOUNT EPO SWITCH AND PROTECTIVE COVER, OR PRIOR APPROVED EQUIVALENT. COORDINATE WITH FINAL EQUIPMENT SELECTION. TYPE ‘EPO IMG’, EMERGENCY POWER OFF SWITCH - IMAGING ROOM: PROVIDE STI (SAFETY TECHNOLOGY INTERNATIONAL, INC) MODEL SS2-231PO-EN FLUSH MOUNT EPO SWITCH AND PROTECTIVE COVER, OR PRIOR APPROVED EQUIVALENT. REFER TO IMAGING MANUFACTURER REQUIREMENTS AND DRAWINGS FOR ADDITIONAL REQUIREMENTS. EPO SWITCH SHALL BE COMPATIBLE WITH FINAL EQUIPMENT SELECTION. JUNCTION BOX - CEILING PROVIDE ONE (1) 4" SQUARE, 2-1/8" DEEP JUNCTION BOX RECESSED IN FLOOR WITH BLANK COVERPLATE AND WITH ONE (1) 1” CONDUIT TO ABOVE FINISHED CEILING WHERE NOT INDICATED OTHERWISE. WHERE SHOWN AS PART OF BRANCH CIRCUIT, PROVIDE CONDUCTORS WITHIN CONDUIT TO SOURCE INDICATED ON FLOOR PLANS. JUNCTION BOX - WALL PROVIDE ONE (1) 4" SQUARE, 2-1/8" DEEP JUNCTION BOX WITH SINGLE GANG TRIM RING AND BLANK WALL PLATE WITH ONE (1) 1” CONDUIT TO ABOVE FINISHED CEILING WHERE NOT INDICATED OTHERWISE. WHERE SHOWN ADJACENT TO RECEPTACLES ON FLOOR PLANS, PROVIDE MAXIMUM 12” BETWEEN BACK BOXES. WHERE SHOWN AS PART OF BRANCH CIRCUIT, PROVIDE CONDUCTORS WITHIN CONDUIT TO SOURCE INDICATED ON FLOOR PLANS. RECEPTACLE - NEMA PROVIDE ONE (1) 4" SQUARE, 2 1/8" DEEP JUNCTION BOX WITH 1 GANG TRIM RING. PROVIDE CONDUIT TO ELECTRICAL SOURCE SIZED AS INDICATED BELOW. REFER TO FLOOR PLANS FOR ELECTRICAL SOURCE AND NEMA DESIGNATION. PROVIDE DEVICE, FEEDER, AND CIRCUIT BREAKER AS LISTED BELOW: •NEMA 6-20 & L6-20: 2-#12, #12 GND IN 3/4" CONDUIT; 20A, 2 POLE CIRCUIT BREAKER •NEMA 15-20 & L15-20: 3-#12, #12 GND IN 3/4" CONDUIT; 20A 3 POLE CIRCUIT BREAKER •NEMA 6-30 & L6-30: 2-#10, #10 GND IN 3/4" CONDUIT; 30A, 2 POLE CIRCUIT BREAKER •NEMA 14-30 &L14-30 (CLOTHES DRYER): 3-#10, #10 GND IN 3/4" CONDUIT; 30A, 2 POLE CIRCUIT BREAKER •NEMA 21-30 & L21-30: 4-#10, #10 GND IN 3/4" CONDUIT; 30A, 3 POLE CIRCUIT BREAKER FIRE ALARM SYMBOLS PLAN SYMBOL NAME DETECTOR - SYSTEM SMOKE - CEILING HORN AND STROBE COMBINATION - CEILING STROBE - CEILING LIGHTING DEVICE SYMBOLS PLAN SYMBOL NAME LIGHT SWITCH SWITCH - 3 WAY SWITCH - DIMMER LIGHTING DEVICE SYMBOL LEGEND PLAN SYMBOL NAME DESCRIPTION PUSH BUTTON DEVICE SHALL PROVIDE ON/OFF CONTROL OF ZONES INDICATED. SUBSCRIPT LETTER(S) CORRESPOND TO LIGHTING ZONE(S) IN AREA. PROVIDE DEVICE CAPABLE OF SWITCHING QUANTITY OF ZONES INDICATED. WHERE NO ZONES ARE INDICATED, PROVIDE CONTROL OF SINGLE ZONE. MUST BE CAPABLE OF 3 AND 4 WAY SWITCHING FROM ADDITIONAL DEVICES. TYPE ‘D’ – DEVICE SHALL PROVIDE ON/OFF AND MIN/MAX DIMMING CONTROL OF ZONES INDICATED. SUBSCRIPT LETTER(S) CORRESPOND TO LIGHTING ZONE(S) IN AREA, PROVIDE DEVICE CAPABLE OF SWITCHING QUANTITY OF ZONES INDICATED. MUST BE CAPABLE OF 3 AND 4 WAY SWITCHING FROM ADDITIONAL DEVICES. ELECTRICAL MISC SYMBOLS PLAN SYMBOL NAME BRANCH CIRCUIT CONCEALED IN CEILING OR WALL CONDUIT BREAK HOMERUN TO PANEL G = GFCI CIRCUIT (PART) = PARTIAL CIRCUIT SWITCHED RECEPTACLE ELECTRICAL MISC SYMBOL LEGEND PLAN SYMBOL NAME DESCRIPTION LIGHTING CONTROL TAG REFER TO LIGHTING CONTROL SCHEDULE FOR ADDITIONAL INFORMATION. LOW VOLTAGE COORDINATION LEGEND SYSTEMS ROUGH-INS & PATHWAYS CABLING & TERMINATIONS DEVICES & EQUIPMENT REMARKS ACCESS CONTROL CF / CI OF / OI OF / OI - AUDIO / VIDEO INTERCOM CF / CI OF / OI OF / OI - FIRE ALARM CF / CI CF / CI CF / CI 1 LIGHTING CONTROLS CF / CI CF / CI CF / CI - NURSE CALL CF / CI OF / OI OF / OI - PUBLIC ADDRESS CF / CI OF / OI CF / CI - SECURITY SURVEILLANCE (CCTV) CF / CI OF / OI OF / OI - VOICE / DATA CF / CI OF / OI OF / OI - WIRELESS ACCESS POINTS CF / CI OF / OI OF / OI - NURSE CALL SYMBOLS PLAN SYMBOL NAME DEFAULT MOUNTING HEIGHT ROUGH-IN ROUGH-IN CODE BLUE STATION 48" 4" SQUARE, 2-1/8" DEEP BACK BOX WITH 1 GANG TRIM RING ROUGH-IN DOME LIGHT - WALL 80" 4" SQUARE, 2-1/8" DEEP BACK BOX WITH 1 GANG TRIM RING ONE LINE SYMBOL PLAN SYMBOL NAME AUTOMATIC TRANSFER SWITCH CONTINUATION CURRENT TRANSFORMER DISCONNECT SWITCH GROUND BAR GROUNDING ELECTRODE PANEL BOARD SURGE PROTECTIVE DEVICE TRANSFORMER UTILITY METER SECURITY SYMBOLS PLAN SYMBOL NAME ROUGH-IN ACCESS CONTROL CREDENTIAL CARD READER ELECTRICAL EQUIPMENT SYMBOLS PLAN SYMBOL NAME DISTRIBUTION PANEL ENCLOSED DISCONNECT SWITCH - NON-FUSED PANELBOARD - SURFACE DATA SYMBOLS PLAN SYMBOL NAME ROUGH-IN COMMUNICATIONS OUTLET - WALL COMMUNICATION SYMBOLS PLAN SYMBOL NAME SCHOOL COMMUNICATION SPEAKER - CEILING 11/08/2024 ELECTRICAL SPECIFICATIONS 284621 -DIGITAL, ADDRESSABLE FIRE -ALARM SYSTEM 1. FIRE-ALARM SYSTEM COMPONENTS SHALL BE INDIVIDUALLY ADDRESSABLE AND BE COMPATIBLE WITH, AND OPERATE AS, AN EXTENSION OF EXISTING SYSTEM. EXPAND, MODIFY, AND SUPPLEMENT EXISTING EQUIPMENT AND PROGRAMMING AS NECESSARY TO EXTEND EXISTING FUNCTIONS TO THE NEW POINTS. SYSTEM AND COMPONENTS SHALL MATCH THE EXISTING MANUFACTURER AND TYPE. COORDINATE WITH MANUFACTURER FOR REQUIRED COMPONENTS. 2. PROVIDE SUBMITTALS TO ARCHITECT INCLUDING PRODUCT DATA AND SHOP DRAWINGS. SUBMITTALS SHALL SHOW EVIDENCE OF REVIEW BY AUTHORITIES HAVING JURISDICTION. PROVIDE PRODUCT DATA FOR EACH TYPE OF PRODUCT BEING INSTALLED. COMPLY WITH NFPA 72. 3. PROVIDE ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES THAT ARE LISTED AND LABELED AS DEFINED IN NFPA 70 BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. OBTAIN CERTIFICATION ACCORDING TO NFPA 72 BY A UL-LISTED ALARM COMPANY. 4. PERSONNEL SHALL BE TRAINED AND CERTIFIED BY MANUFACTURER FOR INSTALLATION OF UNITS REQUIRED FOR THIS PROJECT, AND SHALL BE DIRECTLY SUPERVISED BY A NICET LEVEL III TECHNICIAN. COMPLY WITH NFPA 72 FOR INSTALLATION OF FIRE-ALARM EQUIPMENT. 5. MAINTAIN EXISTING EQUIPMENT FULLY OPERATIONAL UNTIL NEW EQUIPMENT HAS BEEN TESTED AND ACCEPTED. IF EXISTING EQUIPMENT CANNOT BE MAINTAINED IN OPERATION OR REQUIRES INTERRUPTION OF FOUR HOURS OR LONGER, PROVIDE TEMPORARY PROVISIONS OR GUARD SERVICE IN A MANNER ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. NOTIFY OWNER NO FEWER THAN SEVEN DAYS IN ADVANCE OF PROPOSED INTERRUPTIONS, AND ONLY AFTER RECEIVING WRITTEN PERMISSION FROM OWNER. LABEL INACTIVE EQUIPMENT AS "NOT IN SERVICE" UNTIL ACTIVATED OR REMOVED. AFTER ACCEPTANCE OF NEW FIRE-ALARM SYSTEM, REMOVE EXISTING DISCONNECTED FIRE-ALARM EQUIPMENT AND WIRING. 6. SMOKE DAMPERS SHALL BE CONNECTED TO ACTUATE UPON DETECTION OF SMOKE WITHIN THE AREA OR DUCT AND SHALL SHUT-DOWN THE ASSOCIATED FAN SOURCE. DUCT DETECTION SHALL BE CONNECTED TO ACTUATE SMOKE DAMPERS AND SHUT-DOWN THE ASSOCIATED FAN SOURCE. 7. INSTALL REMOTE STATUS INDICATORS AND TEST SWITCH NEAR EACH SMOKE DETECTOR AND EACH SPRINKLER WATER-FLOW SWITCH AND VALVE-TAMPER SWITCH THAT IS NOT READILY VISIBLE FROM NORMAL VIEWING POSITION OR NOT READILY ACCESSIBLE. 8. AVOID INSTALLING SMOKE DETECTION HEADS UNTIL FINAL CLEANUP OF ALL TRADES IS COMPLETE. IF THIS IS UNAVOIDABLE, PROTECT DETECTORS AND PROVIDE CLEANING PRIOR TO FINAL FIRE ALARM TESTING. 9. LOCATE DEVICES PER NFPA 72 AND ADA. 10. SYNCHRONIZE NEW STROBES AND EXISTING STROBES WITHIN COMMON VIEW. MAINTAIN SYNCHRONIZATION OF EXISTING STROBES. 11. PERFORM FIELD TESTS, WITNESSED BY AUTHORITIES HAVING JURISDICTION. ENGAGE A FACTORY- AUTHORIZED SERVICE REPRESENTATIVE TO INSPECT COMPONENTS, ASSEMBLIES, AND EQUIPMENT INSTALLATIONS, INCLUDING CONNECTIONS, AND TO ASSIST IN TESTING. CONDUCT VISUAL INSPECTION PRIOR TO TESTING. COMPLY WITH ALL TESTING PROCEDURES REQUIRED BY NFPA 72. TESTING SHALL INCLUDE NEW SYSTEM EQUIPMENT/FUNCTIONS AND REQUIRED EXISTING SYSTEM EQUIPMENT/FUNCTIONS. FIRE-ALARM SYSTEM WILL BE CONSIDERED DEFECTIVE IF IT DOES NOT PASS TESTS AND INSPECTIONS. ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN FIRE-ALARM SYSTEM. 12. INSTALL CABLES IN EMT CONDUIT. CONCEAL CONDUIT EXCEPT IN UNFINISHED SPACES. 13. PROVIDE 120V AC SERVICE TO REMOTE POWER SUPPLIES AND AMPLIFIERS. 14. PROVIDE LOW AIR PRESSURE SWITCH OPERATION ON A DRY PIPE OR PREACTION SPRINKLER SYSTEM. PROVIDE AN ALARM-INITIATING CONNECTION TO AUTOMATIC SPRINKLER SYSTEM WATER FLOW ALARM DEVICES. 15. DELEGATED DESIGN SUBMITTAL SHALL BE PERFORMED BY A NICET CERTIFIED AND LICENSED PROFESSIONAL ENGINEER. ENGINEER SHALL VISIT THE SITE TO SURVEY AND DESIGN THE SYSTEM. SHOP DRAWINGS SHALL BE STAMPED BY A PE IN THE STATE WHERE THE PROJECT IS LOCATED. A. SHOP DRAWINGS SHALL INCLUDE DETAILED CALCULATIONS FOR THE ENTIRE SYSTEM, INCLUDING VOLTAGE DROP CALCULATIONS, DETECTOR COVERAGE, SOUND-PRESSURE LEVELS, STROBE LIGHT LEVELS, BATTERY SIZING CALCULATIONS, ETC. 16. PROVIDE TEMPORARY HEAT DETECTORS IN THE CONSTRUCTION AREA TO MEET CODE REQUIREMENTS. 17. BASIC ALARM PERFORMANCE REQUIREMENTS: UNLESS OTHERWISE INDICATED, MANUAL OPERATION OF A PULL STATION, AUTOMATIC ALARM OPERATION OF A HEAT DETECTOR, OPERATION OF A SPRINKLER FLOW DEVICE, OR VERIFIED AUTOMATIC ALARM OPERATION OF A SMOKE DETECTOR INITIATES THE FOLLOWING: A. NOTIFICATION APPLIANCE OPERATION. B. IDENTIFICATION AT THE FACP AND IF REQUIRED THE REMOTE ANNUNCIATOR OF THE ZONE ORIGINATING THE ALARM. C. TRANSMISSION OF AN ALARM SIGNAL TO THE REMOTE ALARM RECEIVING STATION. D. SHUTDOWN OF FANS AND/OR OTHER AIR-HANDLING EQUIPMENT. E. CONTROL OF SMOKE DAMPERS IN AIR DUCTS OF SYSTEM. 18. ALARM SILENCING, SYSTEM RESET AND INDICATION: CONTROLLED BY SWITCHES IN THE FACP AND IF APPLICABLE THE REMOTE ANNUNCIATOR. 19. REMOVAL OF AN ALARM INITIATING DEVICE AND/OR A NOTIFICATION APPLIANCE INITIATES THE FOLLOWING: A. A "TROUBLE" SIGNAL INDICATION AT THE FACP AND IF APPLICABLE THE REMOTE ANNUNCIATOR FOR THE DEVICE OR ZONE INVOLVED. B. TRANSMISSION OF TROUBLE SIGNAL TO REMOTE ALARM RECEIVING STATION. 260000 -GENERAL ELECTRICAL REQUIREMENTS 1. CONTRACTOR SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES. 2. CONTRACTOR SHALL MAKE APPLICATION FOR OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND CERTIFICATES OF INSPECTION. 3. THE OWNER WILL HAVE FIRST RIGHT OF SALVAGE FOR ITEMS REMOVED. CONTRACTOR SHALL DISPOSE OF ITEMS REMOVED IF NOT SALVAGED. 4. PROVIDE PRODUCT DATA SUBMITTALS FOR FIRE-ALARM DEVICES, WIRING DEVICES, AUTOMATIC LIGHTING CONTROL DEVICES, AND INTERIOR LIGHTING. 5. WARRANTIES A. THE CONTRACTOR SHALL WARRANT ALL MATERIALS, WORKMANSHIP, AND EQUIPMENT AGAINST DEFECTS FOR A PERIOD OF ONE YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION. CERTAIN EQUIPMENT SHALL BE WARRANTED BEGINNING AT THE TIME OF FINAL ACCEPTANCE OR FOR LONGER PERIODS OF TIME AS SPECIFIED IN THOSE DIVISIONS OF THE PROJECT MANUAL. THE CONTRACTOR SHALL REPAIR OR REPLACE, AT NO ADDITIONAL COST TO THE OWNER, ANY ITEM WHICH MAY BECOME DEFECTIVE WITHIN THE WARRANTY PERIOD. ANY MANUFACTURERS' WARRANTIES CONCERNING ANY ITEM INSTALLED WILL RUN TO THE BENEFIT OF THE OWNER. THE CONTRACTOR AGREES NOT TO VOID OR IMPAIR, OR TO ALLOW SUB-CONTRACTORS TO VOID OR IMPAIR, ANY WARRANTIES REGARDING PRODUCTS OR ITEMS INSTALLED AS PART OF THIS PROJECT. THE REPAIR OF FAULTY WORKMANSHIP SHALL BE CONSIDERED TO BE INCLUDED IN THE CONTRACT. 6. EQUIPMENT ELECTRICAL CONNECTIONS A. ELECTRICAL CONNECTIONS IDENTIFIED ARE FOR THE SPECIFIC EQUIPMENT MANUFACTURER AND MODEL SCHEDULED, AND INCLUDES EQUIPMENT FURNISHED BY THIS TRADE OR FURNISHED BY OTHER TRADES AS PART OF THESE CONTRACT DOCUMENTS. IF THE CONTRACTOR CHOOSES TO PROVIDE EQUIPMENT FROM A DIFFERENT MANUFACTURER OR MODEL THAN THAT SCHEDULED BUT LISTED AS EQUIVALENT IN THE SPECIFICATIONS, OR OTHERWISE ACCEPTED BY THE ARCHITECT/ENGINEER, THE CONTRACTOR SHALL INCLUDE ELECTRICAL CONNECTION REVISIONS ASSOCIATED WITH THAT MANUFACTURER'S ELECTRICAL CONNECTION REQUIREMENTS IN THEIR BID. 260500 -COMMON WORK RESULTS FOR ELECTRICAL 1. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF THE GENERAL CONDITIONS, SUPPLEMENTAL GENERAL CONDITIONS OF THE PROJECT SPECIFICATIONS, AND CONTRACT DOCUMENTS. 2. DEFINITIONS AND STANDARDS: A. DEFINITIONS: INSTRUCTIONS SUCH AS "PROVIDE THE OUTLETS." SHALL MEAN THE SAME AS THOUGH THE WORDS "THE CONTRACTOR SHALL "PRECEDE EACH SUCH INSTRUCTION. "PROVIDE" SHALL MEAN "FURNISH AND INSTALL". B. STANDARDS FOR MATERIALS: MATERIALS SHALL BE NEW EXCEPT AS OTHERWISE STATED, AND SHALL CONFORM WITH THE CURRENT APPLICABLE INDUSTRY STANDARDS, NEMA STANDARDS, AND UNDERWRITERS' LABORATORIES STANDARDS. 3. COORDINATE ARRANGEMENT, MOUNTING, AND SUPPORT OF ELECTRICAL EQUIPMENT WITH OTHER TRADES. 4. STEEL PIPE SLEEVES: ASTM A 53/A 53M, TYPE E, GRADE B, SCHEDULE 40, GALVANIZED STEEL, PLAIN ENDS. 5. PROVISIONS SHALL BE MADE FOR SAFE DELIVERY AND SECURE STORAGE OF ALL MATERIALS. 6. WORK SHALL BE PERFORMED TO CLIENT SAFETY STANDARDS, NFPA 70E, AND OSHA REGULATIONS. WORK SHALL BE ACCOMPLISHED WITH AFFECTED CIRCUITS DE-ENERGIZED. 7. ONLY QUALIFIED, PROPERLY TRAINED, AND LICENSED PERSONNEL SHALL PERFORM THIS WORK. 8. WORK SHALL CONFORM TO CLIENT FACILITY STANDARDS. 9. PROVIDE NECESSARY LABOR, MATERIALS, EQUIPMENT, AND ACCESSORIES FOR THE ELECTRICAL SYSTEMS TO BE INSTALLED ACCORDING TO MANUFACTURER INSTRUCTIONS. INSTALLATIONS SHALL BE IN A NEAT AND WORKMEN LIKE MANNER BY SKILLED AND COMPETENT ELECTRICIANS IN CONFORMANCE WITH THE STANDARD PRACTICES OF THE ELECTRICAL INDUSTRY. GOOD WORKMANSHIP AND APPEARANCE ARE CONSIDERED EQUAL TO PROPER OPERATION. 10. MATERIALS SHALL BE SPECIFICALLY INTENDED AND UL LISTED FOR THEIR APPLICATION. 11. MATERIALS SHALL BE SUITABLY RATED FOR THEIR OPERATING ENVIRONMENT FOR WET LOCATIONS, SUNLIGHT EXPOSURE, TEMPERATURE RANGES, AND OTHER ENVIRONMENTAL VARIABLES. WORK THAT PIERCES WATERPROOFING SHALL BE INSTALLED TO MAINTAIN THE INTEGRITY OF THE WATERPROOFING. 12. PROVIDE CORE DRILLING, CHANNELING, CUTTING, PATCHING, SLEEVES, ETC. AS REQUIRED FOR INSTALLATION OF ELECTRICAL EQUIPMENT. SEAL HOLES, FIREPROOFING WHERE NECESSARY, AND REFINISH REPAIR WORK TO ORIGINAL CONDITION WHERE DAMAGED BY ELECTRICAL W ORK. 13. MATERIALS SHALL HAVE SEISMIC BRACING PER ASCE 7. REFER TO STRUCTURAL RECORD DRAWINGS TO VERIFY SEISMIC CHARACTERISTICS OF THE FACILITY. THE FACILITY HAS A SEISMIC DESIGN CATEGORY OF C AND AN OCCUPANCY CATEGORY OF Hosp.-IV. 14. COORDINATE AND DIRECT THE PROGRESS OF ELECTRICAL WORK TO CONFORM TO THE OWNER'S SCHEDULE AND THE PROGRESS OF THE WORK OF THE OTHER TRADES. 15. AT COMPLETION OF WORK, DELIVER COMPLETED PROJECT RECORD DOCUMENTS MARKED WITH FIELD CHANGES TO THE ARCHITECT/OWNER. 16. COMPLY WITH NECA 1. 17. RIGHT OF WAY -GIVE TO RACEWAYS AND PIPING SYSTEM INSTALLED AT A REQUIRED SLOPE. 18. APPLY FIRESTOPPING TO ELECTRICAL PENETRATIONS OF FIRE-RATED FLOOR AND WALL ASSEMBLIES. 19. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100. 20. ELECTRICAL DEVICES MOUNTING HEIGHTS SPECIFIED ON ARCHITECTURAL DOCUMENTS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS INDICATED BELOW: A. TYPICAL MOUNTING HEIGHTS (MEASURED TO THE CENTER OF THE DEVICE): a. WALL SWITCHES: 48 INCHES. b. RECEPTACLE OUTLETS (GENERAL): 18 INCHES. c. RECEPTACLE OUTLETS (ABOVE WORK SURFACES): 4 INCHES ABOVE COUNTERTOP/BACKSPLASH. d. SPECIAL-PURPOSE OUTLETS: WITHIN 72 INCHES OF INTENDED USE. e. COMMUNICATIONS OUTLETS: 18 INCHES. f. FIRE-ALARM NOTIFICATION APPLIANCE: 82 INCHES TO CENTER OF STROBE. IF THIS HEIGHT WOULD RESULT IN BEING WITHIN 6" OFF THE CEILING COORDINATE HEIGHT WITH AHJ. g. PUSH BUTTONS: 48 INCHES. h. EXIT SIGNS: 4 INCHES BETWEEN TOP OF DOOR FRAME AND BOTTOM OF EXIT SIGN WHERE POSSIBLE. 21. INCIDENTAL EQUIPMENT: A. CONTRACTOR SHALL PROVIDE ELECTRICAL CONNECTIONS AND DISCONNECTS FOR INCIDENTAL EQUIPMENT. CONNECTIONS INCLUDE REQUIRED LINE VOLTAGE BRANCH CIRCUITS ANDFIRE ALARM. "INCIDENTAL EQUIPMENT" SHALL MEAN EQUIPMENT FURNISHED BY THIS TRADE, OR FURNISHED BY OTHER TRADES UNDER THESE PROJECT DOCUMENTS, THAT IS NOT SPECIFICALLY IDENTIFIED OR LOCATED ON THE PLANS. EXAMPLES INCLUDE, BUT ARE NOT LIMITED TO, BUILDING MANAGEMENT CONTROL PANELS, FIRE-ALARM REMOTE POWER SUPPLIES, AND MEDICAL GAS ALARM PANELS. COORDINATE REQUIREMENTS WITH EQUIPMENT PROVIDED AND OTHER ASSOCIATED TRADES. 22. SCHEDULED EQUIPMENT: A. PRIOR TO ORDERING AND INSTALLING MATERIAL AND ELECTRICAL EQUIPMENT, VERIFY THAT SCHEDULED CONNECTION REQUIREMENTS ARE CONSISTENT WITH EQUIPMENT BEING PROVIDED. THIS SHALL INCLUDE EQUIPMENT FURNISHED BY THIS TRADE OR FURNISHED BY OTHER TRADES UNDER THESE PROJECT DOCUMENTS. VERIFICATION IS NECESSARY DUE TO THE UNCERTAINTY OF FINAL EQUIPMENT SELECTION PROVIDED BY OTHER TRADES, INCLUDING, BUT NOT LIMITED TO: MECHANICAL EQUIPMENT, ETC. 262726 -WIRING DEVICES 1. CONVENIENCE RECEPTACLES: 125V, 20A, NEMA 5-20R BY HUBBELL, EATON, LEVITON, OR PASS & SEYMOUR (P&S 5381). 2. RECEPTACLES SHALL BE HOSPITAL GRADE THROUGHOUT (ALL RECEPTACLE LOCATIONS). HOSPITAL GRADE RECEPTACLES SHALL BE THE HOSPITAL GRADE EQUIVALENT TO STRAIGHT BLADE RECEPTACLES LISTED ABOVE. 3. RECEPTACLES SHALL BE TAMPER RESISTANT THROUGHOUT (ALL RECEPTACLE LOCATIONS). TAMPER RESISTANT RECEPTACLES SHALL BE THE TAMPER RESISTANT EQUIVALENT TO STRAIGHT BLADE RECEPTACLES LISTED ABOVE. 4. WEATHER RESISTANT RECEPTACLES SHALL BE PROVIDED AT ALL WET LOCATIONS. 5. SNAP SWITCHES: 120/277V, 20A, SPECIFICATION GRADE. (PS 20AC1) 6. FINISHES A. WIRING DEVICE CONNECTED TO NORMAL POWER SYSTEM: AS SELECTED BY ARCHITECT, UNLESS OTHERWISE INDICATED. B. WIRING DEVICE CONNECTED TO EMERGENCY POWER SYSTEM: RED C. WALL PLATE: SMOOTH, HIGH-IMPACT THERMOPLASTIC, COLOR TO MATCH DEVICE. D. MATERIAL FOR DAMP LOCATIONS: CAST ALUMINUM ENCLOSURE WITH SPRING-LOADED LIFT COVER, AND LISTED AND LABELED FOR USE IN "WET LOCATIONS". E. MATERIAL FOR WET LOCATIONS: WEATHERPROOF NEMA 250 ENCLOSURE, COMPLYING WITH TYPE 3R, THERMOPLASTIC WITH LOCKABLE, IN-USE STYLE COVER. 7. INSTALL GROUND PIN OF VERTICALLY MOUNTED RECEPTACLES DOWN. 8. DIMMER SWITCHES: MODULAR, FULL-WAVE, SOLID-STATE UNITS WITH INTEGRAL, QUIET ON-OFF SWITCHES, WITH AUDIBLE FREQUENCY AND EMI/RFI SUPPRESSION FILTERS. COMPATIBLE WITH FIXTURE BEING DIMMED. A. PRODUCTS: LUTRON 'DIVA' SERIES OR PRIOR APPROVED EQUAL. B. CONTROL: CONTINUOUSLY ADJUSTABLE SLIDER; WITH SEPARATELY OPERATED SINGLE-POLE OR THREE- WAY SWITCH ON COMMON DEVICE. COMPLY WITH UL 1472. SEPARATELY OPERATED SWITCH SHALL BE CAPABLE OF SWITCHING LINE VOLTAGE POWER WITHOUT ADDITIONAL POWER PACK. C. COORDINATE DIMMING PROTOCOL WITH FIXTURES BEING DIMMED. 9. INSTALL NON-FEED-THROUGH TYPE GFCI RECEPTACLES UNLESS SPECIFICALLY NOTED OTHERWISE. 260923 -STAND-ALONE AUTOMATIC LIGHTING CONTROLS 1. INDOOR OCCUPANCY SENSORS: CEILING MOUNT, LOW VOLTAGE, DUAL TECHNOLOGY (UNLESS NOTED OTHERWISE), SENSORSWITCH, HUBBELL, EATON, LEVITON, OR WATTSTOPPER. A. CORRIDORS AND VESTIBULES: PASSIVE INFRARED TYPE SENSORS ARE ACCEPTABLE. 2. POWER PACK: DRY CONTACTS RATED FOR 20A LOAD AT 120 AND 277 VAC. PROVIDE POWER PACKS TO ACCOMMODATE QUANTITY OF LIGHTING ZONES AND BRANCH CIRCUITS PER PLANS AND DETAILS. 3. SELECT, INSTALL, AND AIM SENSORS TO ACHIEVE NOT LESS THAN 90 PERCENT COVERAGE OF AREAS SERVED. INDIVIDUAL ROOMS (DEFINED BY FULL HEIGHT WALL PARTITIONS OR DOORS, MAX 5000 SQUARE FEET) SHALL BE CONTROLLED INDEPENDENT OF ADJACENT ROOMS. 265100 -INTERIOR LIGHTING 1. PROVIDE PRODUCT DATA FOR EACH TYPE OF LIGHTING FIXTURE. 2. RECESSED FIXTURES: COMPLY WITH NEMA LE 4 FOR CEILING COMPATIBILITY FOR RECESSED LUMINAIRES. 3. LED LUMINAIRES: A. COMPLY WITH UL 1598 AND UL 8750. B. EACH LUMINAIRE SHALL BE RATED FOR A MINIMUM OPERATIONAL LIFE (L70) OF 50,000 HOURS AS DEFINED BY IES LM-80 AND TM-21. C. ABSOLUTE PHOTOMETRICS SHALL BE AVAILABLE FOR EACH LUMINAIRE BASED ON IES LM-79. D. INDIVIDUAL LEDS WITHIN THE LUMINAIRE SHALL BE CONNECTED SUCH THAT LOSS OR FAILURE OF A SINGLE LED WILL NOT RESULT IN THE LOSS OF THE ENTIRE ARRAY. E. LED LUMINAIRES SHALL HAVE A MINIMUM CRI OF 90 UNLESS NOTED OTHERWISE. F. LUMINAIRE POWER FACTOR: 0.90 OR HIGHER. G. TOTAL HARMONIC DISTORTION RATING: <20% 260519 -CONDUCTORS AND CABLES FOR ELECTRICAL 1. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. COMPLY WITH NFPA 70. 2. COPPER CONDUCTORS: COMPLY WITH NECA WC70 AND UL RATING. 3. CONDUCTOR INSULATION: COMPLY WITH NEMA WC 70 FOR TYPES THHN-THWN. A. WIRING TERMINATIONS IN LIGHT FIXTURES AND TRANSFORMERS SHALL BE RATED 90C AS REQUIRED BY THE MANUFACTURER. 4. CONNECTORS AND SPLICES: FACTORY-FABRICATED CONNECTORS AND SPLICES OF SIZE, AMPACITY RATING, MATERIAL, TYPE, AND CLASS FOR APPLICATION AND SERVICE INDICATED. 5. FEEDERS AND BRANCH CIRCUITS: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY. 6. CONCEAL CABLES IN FINISHED WALLS, CEILINGS, AND FLOORS, UNLESS OTHERWISE INDICATED. ROUTE CABLES IN CONDUIT WHEN REQUIRED BY THE APPLICABLE SPECIFICATION SECTION. 7. PROVIDE DEDICATED NEUTRALS FOR ALL BRANCH CIRCUITS. 8. SIZING: MINIMUM SIZE #12, EXCEPT FOR CONTROL OR SIGNAL CIRCUITS, WHICH MAY BE #14 WHERE THE MANUFACTURER'S REQUIREMENTS ALLOW. 260526 -GROUNDING AND BONDING FOR ELECTRICAL 1. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. COMPLY WITH UL 467 FOR GROUNDING AND BONDING MATERIALS AND EQUIPMENT. 2. CONDUCTORS: A. INSULATED CONDUCTORS: COPPER WIRE OR CABLE INSULATED FOR 600 V UNLESS OTHERWISE REQUIRED BY APPLICABLE CODE OR AUTHORITIES HAVING JURISDICTION. B. BARE COPPER CONDUCTORS: a. SOLID CONDUCTORS: ASTM B 3. b. STRANDED CONDUCTORS: ASTM B 8. c. BONDING CABLE: 28 KCMIL, 14 STRANDS OF NO.17 AWG CONDUCTOR, 1/4 INCH IN DIAMETER. d. BONDING CONDUCTOR: NO.4 OR NO.6 AWG, STRANDED CONDUCTOR. e. BONDING JUMPER: COPPER TAPE, BRAIDED CONDUCTORS, TERMINATED WITH COPPER FERRULES; 1-5/8 INCHES WIDE AND 1/16 INCH THICK. f. GROUND BAR: RECTANGULAR BARS OF ANNEALED COPPER, 1/4-BY-4 INCHES IN CROSS SECTION, UNLESS OTHERWISE INDICATED; WITH INSULATORS. LENGTH AS REQUIRED TO ACCOMMODATE TERMINATIONS. 3. CONNECTORS: LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION FOR APPLICATIONS IN WHICH USED, AND FOR SPECIFIC TYPES, SIZES, AND COMBINATIONS OF CONDUCTORS AND OTHER ITEMS CONNECTED. 4. GROUND RODS: COPPER-CLAD STEEL; 3/4 INCH IN DIAMETER BY 10 FEET IN LENGTH. 5. INSTALL INSULATED EQUIPMENT GROUNDING CONDUCTORS WITH ALL FEEDERS AND BRANCH CIRCUITS. 6. ROUTE GROUNDING CONDUCTORS ALONG SHORTEST AND STRAIGHTEST PATHS POSSIBLE, UNLESS OTHERWISE INDICATED OR REQUIRED BY CODE. AVOID OBSTRUCTING ACCESS OR PLACING CONDUCTORS WHERE THEY MAY BE SUBJECTED TO STRAIN, IMPACT, OR DAMAGE. 7. GROUND CONNECTIONS SHALL HAVE CLEAN CONTACT SURFACES, TINNED, AND SWEATED WHILE BOLTING. INSTALL GROUND CONDUCTORS IN CONDUIT. NON-CONDUCTIVE SURFACES SUCH AS PAINT SHALL BE REMOVED. 260529 -HANGERS AND SUPPORTS FOR ELECTRICAL 1. COMPLY WITH NFPA 70. 2. DESIGN SUPPORTS CAPABLE OF SUPPORTING COMBINED WEIGHT OF SUPPORTED EQUIPMENT AND ITS CONTENTS. 3. SUPPORTS SHALL BE ADEQUATE IN TENSION, SHEAR, AND PULLOUT FORCE TO RESIST MAXIMUM LOADS CALCULATED OR IMPOSED FOR THIS PROJECT, WITH A MINIMUM STRUCTURAL SAFETY FACTOR OF FIVE TIMES THE APPLIED FORCE. 4. RACEWAY AND CABLE SUPPORTS: AS DESCRIBED IN NECA 1 AND NECA 101. 5. CONDUIT AND CABLE SUPPORT DEVICES: STEEL AND MALLEABLE-IRON HANGERS, CLAMPS, AND ASSOCIATED FITTINGS, DESIGNED FOR TYPES AND SIZES OF RACEWAY OR CABLE TO BE SUPPORTED. 6. SPACE SUPPORTS FOR CONDUIT AS REQUIRED BY NFPA 70. MINIMUM ROD SIZE SHALL BE 1/4 INCH IN DIAMETER. 7. INSTALL TRAPEZE-TYPE SUPPORTS FABRICATED WITH STEEL SLOTTED SUPPORT SYSTEM, SIZED SO CAPACITY CAN BE INCREASED BY AT LEAST 25 PERCENT IN FUTURE WITHOUT EXCEEDING SPECIFIED DESIGN LOAD LIMITS. SECURE RACEWAYS AND CABLES TO THESE SUPPORTS WITH TWO-BOLT CONDUIT CLAMPS. 8. SUPPORT JUNCTION BOXES AND LIGHT FIXTURES DIRECTLY FROM STRUCTURE INDEPENDENTLY OF CONDUITS OR OTHER TRADES. SUPPORTING SHALL ENSURE THE CEILING SYSTEMS HAVE NO VISIBLE BOWING OR DEFLECTION. 9. STEEL MATERIAL SHALL BE USED FOR DRY LOCATIONS. 260533 -RACEWAYS AND BOXES FOR ELECTRICAL 1. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. 2. DRAWINGS ARE DIAGRAMMATIC. ALL BENDS, BOXES, FITTINGS, COUPLINGS ARE NOT NECESSARILY SHOWN. SUPPLY AS NECESSARY TO COMPLY WITH NFPA 70. 3. RIGID STEEL CONDUIT: ANSI C80.1. 4. EMT: ANSI C80.3. 5. LFMC: FLEXIBLE STEEL CONDUIT WITH PVC JACKET. 6. FITTINGS FOR CONDUIT (INCLUDING ALL TYPES AND FLEXIBLE AND LIQUIDTIGHT), EMT, AND CABLE: NEMA FB 1; LISTED FOR TYPE AND SIZE RACEWAY WITH WHICH USED, AND FOR APPLICATION AND ENVIRONMENT IN WHICH INSTALLED. a. FITTINGS FOR EMT: STEEL OR DIE-CAST, SET-SCREW OR COMPRESSION TYPE. 7. SHEET METAL OUTLET AND DEVICE BOXES: NEMA OS 1. 8. CONCEAL CONDUIT WITHIN FINISHED WALLS, CEILINGS, FLOORS, AND BELOW EXTERIOR GRADES UNLESS SURFACE MOUNTING IS SPECIFICALLY INDICATED ON PLANS. 9. CONDUIT SHALL BE ROUTED PARALLEL OR PERPENDICULAR WITH THE BUILDING WALLS. SUPPORT CONDUIT AS REQUIRED BY THE NATIONAL ELECTRICAL CODE. 10. KEEP RACEWAYS ABOVE AND 6" OR MORE HORIZONTALLY AWAY FROM PARALLEL RUNS OF FLUES AND STEAM OR HOT-WATER PIPES. 11. INSTALL SEALS ON THE INTERIOR OF CONDUITS WHERE THE CONDUIT PASSES BETWEEN TWO SPACES WITH SIGNIFICANTLY DIFFERENT ENVIRONMENT OR TEMPERATURE CONDITIONS. 12. PROVIDE EXPANSION TYPE FITTINGS FOR CONDUITS WHICH CROSS EXPANSION JOINTS. 13. RACEWAY APPLICATION: A. OUTDOOR EXPOSED: RIGID STEEL CONDUIT. B. CONNECTION TO VIBRATING EQUIPMENT (INCLUDING TRANSFORMERS AND HYDRAULIC, PNEUMATIC, ELECTRIC SOLENOID, OR MOTOR-DRIVEN EQUIPMENT): LFMC. C. OUTDOOR BOXES AND ENCLOSURES, ABOVEGROUND: NEMA 250, TYPE 3R. D. INDOOR: EMT. 14. MINIMUM RACEWAY SIZE: 3/4-INCH TRADE SIZE, 1-INCH TRADE SIZE FOR VOICE AND DATA COMMUNICATIONS. 15. PAINT JUNCTION BOX COVERS WITH THE FOLLOWING FINISHES BY BRANCH/SYSTEM. • FIRE ALARM SYSTEM: RED. • LOW VOLTAGE/DATA: WHITE. • NURSE CALL SYSTEM: BLUE. 16. INSTALL PULL WIRES IN EMPTY RACEWAYS. USE POLYPROPYLENE OR MONOFILAMENT PLASTIC LINE WITH NOT LESS THAN 200-LB TENSILE STRENGTH. LEAVE AT LEAST 12 INCHES OF SLACK AT EACH END OF PULL WIRE. 260553 -ELECTRICAL IDENTIFICATION 1. COORDINATE IDENTIFICATION NAMES, COLORS, AND OTHER FEATURES WITH REQUIREMENTS IN THE CONTRACT DOCUMENTS, AND WITH THOSE REQUIRED BY CODES. USE CONSISTENT DESIGNATIONS THROUGHOUT PROJECT. MATCH EXISTING OWNER STANDARDS WHERE APPLICABLE. 2. CONDUCTOR IDENTIFICATION MATERIALS: COLORED TAPE: VINYL, SELF-ADHESIVE TYPE. 3. WIRING DEVICE WALL PLATE LABELS: MACHINE-PRINTED, ADHESIVE TAPE LABEL, CLEAR WITH BLACK LETTERS. A. RECEPTACLE WALL PLATES: LIST PANEL AND BRANCH CIRCUIT NUMBER. WHERE SERVED FROM A GFCI CIRCUIT BREAKER, INDICATE LETTER “G”AT THE END OF THE CIRCUIT NUMBER DESIGNATION. B. LIGHT SWITCH WALL PLATES: WHERE TWO OR MORE SWITCHES ARE GANGED TOGETHER, PROVIDE DESCRIPTION OF AREA OR FUNCTION FOR EACH SWITCH. 4. EQUIPMENT IDENTIFICATION LABELS: ENGRAVED OR MELAMINE LABEL: ADHESIVE BACKED, WITH WHITE OR BLACK LETTERS ON A COLORED BACKGROUND. MINIMUM LETTER HEIGHT SHALL BE 3/8 INCH. A. BACKGROUND COLOR: MATCH OWNER’S STANDARD. B. MECHANICAL EQUIPMENT: PROVIDE LABEL INDICATING EQUIPMENT NAME AS WELL AS PANEL NAME AND CIRCUIT NUMBER FEEDING THE EQUIPMENT. LOCATE ON EQUIPMENT DISCONNECT. LOCATE LABEL WITHIN SITE OF THE EQUIPMENT. C. PANELBOARDS AND ENCLOSED CIRCUIT BREAKERS: LABEL SHALL IDENTIFY EQUIPMENT NAME, SYSTEM BRANCH, VOLTAGE, AND SOURCE “FED FROM”. 5. EXISTING PANELBOARD DIRECTORIES: PROVIDE UPDATED-TYPED CIRCUIT DIRECTORIES FOR EXISTING PANELS AFFECTED. 6. LABEL JUNCTION BOX COVERS LOCATED ABOVE ACCESSIBLE CEILINGS OR IN UNFINISHED SPACES WITH BLACK PERMANENT INK MARKER INDICATING PANEL AND CIRCUIT NUMBER, OR EQUIVALENT SYSTEM INFORMATION. PROVIDE LABELING OF SYSTEM NAME ON COVERS FOR SYSTEMS ENCLOSED IN CONDUIT. FOR EXAMPLE “NURSE CALL”LABEL COVER NURSE CALL. WHERE CONDUIT IS EXPOSED AND PAINTED, PROVIDE LABEL ON INSIDE OF JUNCTION BOX COVER. REFER TO RACEWAY AND BOXES FOR ELECTRICAL SPECIFICATION FOR COLOR CODE. 7. FIRE/SMOKE BARRIER PENETRATION LABELING: AFFIX LABEL AT EVERY RATED FIRE/SMOKE BARRIER PENETRATED WITH ELECTRICAL SYSTEMS, CONDUIT, AND SYSTEMS PATHWAYS. 8. CONDUCTOR COLOR-CODING FOR PHASE IDENTIFICATION. COLOR SHALL BE FACTORY APPLIED: a. COLORS FOR 208/120V CIRCUITS: • PHASE A: BLACK. • PHASE B: RED. • PHASE C: BLUE. • NEUTRAL: WHITE. • GROUND -GREEN • SWITCH TRAVELERS -PINK b. COLORS FOR 480/277V CIRCUITS: • PHASE A: BROWN. • PHASE B: ORANGE. • PHASE C: YELLOW. • NEUTRAL: GRAY. • GROUND -GREEN • SWITCH TRAVELERS -PURPLE c. WIRING FOR CONTROL SYSTEMS SHALL BE COLOR CODED IN ACCORDANCE WITH THE WIRING DIAGRAMS FURNISHED WITH THE EQUIPMENT. d. CONDUCTORS NO. 2 AWG AND SMALLER SHALL BE FACTORY COLOR CODED. WIRE NO. 1 AWG AND LARGER MAY BE COLOR CODED BY FIELD PAINTING OR COLOR TAPING A 6 INCH LENGTH OF THE EXPOSED END. e. NEUTRAL IDENTIFICATION: WHERE INDIVIDUAL (DEDICATED) NEUTRAL CONDUCTORS ARE REQUIRED FOR SINGLE-PHASE 120 VOLT AND 277 VOLT BRANCH CIRCUITS, NEUTRAL CONDUCTOR SHALL HAVE FACTORY APPLIED COLOR STRIPE (TRACER) ALONG THE LENGTH OF THE CONDUCTOR, WITH TRACER COLOR TO MATCH ASSOCIATED PHASE CONDUCTOR. 262816 -ENCLOSED SWITCHES AND CIRCUIT BREAKERS 1. PROVIDE SPARE FUSES EQUAL TO 10% OF QUANTITY INSTALLED BUT NO FEWER THAN THREE OF EACH SIZE AND TYPE TO MAINTENANCE DEPARTMENT OR MOUNTED NEAR NEW DISCONNECT. 2. DISCONNECT SWITCHES SHALL BE TYPE HD UNLESS THEY ARE REQUIRED TO BE MOTOR-RATED. 3. FUSIBLE DISCONNECTS SHALL BE PROVIDED WITH CLASS R REJECTION CLIPS. 4. CIRCUIT BREAKERS SHALL BE MOLDED-CASE, THERMAL-MAGNETIC TYPE, WITH INTERRUPTING CAPACITY TO MEET AVAILABLE FAULT CURRENTS. CIRCUIT BREAKERS RATED LARGER THAN 250A SHALL HAVE AN ELECTRONIC TRIP UNIT WITH ADJUSTABLE L-S-I SETTINGS UNLESS THEY ARE SERVED BY A 208V SECONDARY TRANSFORMER RATED LESS THAN 125kVA. 5. ENCLOSURES: NEMA TYPE SUITABLE FOR THE SURROUNDING AREA AND CONDITIONS. 6. MANUFACTURER OF SWITCHES AND CIRCUIT BREAKERS: A. EATON ELECTRICAL INC.; CUTLER-HAMMER BUSINESS UNIT. B. ABB/GE. C. SIEMENS ENERGY & AUTOMATION, INC. D. SQUARE D; A BRAND OF SCHNEIDER ELECTRIC. 260943 -ADDRESSABLE NETWORK LIGHTING CONTROLS 1. PROVIDE FLOOR PLAN SHOP DRAWINGS THAT INDICATE LOCATION, ORIENTATION, AND COVERAGE AREA OF EACH SENSOR, GROUPS, ZONES, SCENES, AND OTHER SPECIFIC DESIGN SYMBOLS AND DESIGNATIONS AS REQUIRED TO DEFINE THE INSTALLATION, LOCATION, AND CONFIGURATION OF ALL CONTROL DEVICES. 2. ENSURE THAT LIGHTING SYSTEM CONTROL DEVICES AND ASSEMBLIES ARE FULLY COMPATIBLE AND CAN BE INTEGRATED INTO A SYSTEM THAT OPERATES AS DESCRIBED IN THE LIGHTING CONTROL NOTES ON DRAWINGS. ANY INCOMPATIBILITIES BETWEEN DEVICES, FIXTURES, AND SYSTEM CONTROLLERS SHALL BE RESOLVED BETWEEN THE CONTRACTOR AND THE SYSTEM PROVIDER AS REQUIRED TO ENSURE PROPER SYSTEM OPERATION AND MAINTAINABILITY. 3. MANUFACTURERS SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS LISTED WITHIN THIS SPECIFICATION SECTION. PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: A. DIGITAL LIGHTING MANAGEMENT (DLM) FROM WATTSTOPPER. B. ENCELIUM ENERGY MANAGEMENT SYSTEM FROM OSRAM SYLVANIA. C. NLIGHT® NETWORK CONTROL SYSTEM FROM SENSOR SWITCH. D. QUANTUM TOTAL LIGHT MANAGEMENT FROM LUTRON. E. GREEN LIGHT FROM CRESTRON. F. DIALOG FROM DOUGLAS. G. APPROVAL PRIOR TO BID REQUIRED FOR OTHER MANUFACTURERS. 4. SYSTEM SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: A. COMPONENTS: INDIVIDUALLY ADDRESSABLE CONTROL DEVICES (SUCH AS RELAYS, DIMMERS, AND SWITCHES) THAT ARE OPERATED FROM DIGITAL SIGNALS RECEIVED THROUGH A DATA BUS, FROM DATA-ENTRY AND RETRIEVAL DEVICES (SUCH AS PCS, HAND-HELD INFRARED PROGRAMMING DEVICES, AND WIRED NETWORK CONNECTIONS). DEVICES ALSO REPORT STATUS TO DATA-ENTRY AND RETRIEVAL DEVICES THROUGH THE BUS. B. DIGITAL CONTROL: USE PEER-TO-PEER COMMUNICATION AND DISTRIBUTED LOGIC, WHERE THE FAILURE OF ANY SINGLE COMPONENT WITHIN A SCOPE SHALL BE AUTOMATICALLY ISOLATED AND NOT AFFECT FUNCTION OF OTHER SPACES. C. LIGHTING CONTROL ZONES SHALL CONSIST OF ONE OR MORE INTELLIGENT LIGHTING CONTROL COMPONENTS, BE CAPABLE OF STAND-ALONE OPERATION, AND BE CAPABLE OF BEING CONNECTED TO A HIGHER LEVEL NETWORK BACKBONE. D. EACH LIGHTING CONTROL ZONE SHALL BE CAPABLE OF AUTOMATICALLY CONFIGURING ITSELF FOR DEFAULT STAND-ALONE OPERATION WITHOUT ANY START-UP PROGRAMMING. E. INDIVIDUAL LIGHTING ZONES MUST CONTINUE TO PROVIDE A USER DEFINED DEFAULT LEVEL OF LIGHTING CONTROL IN THE EVENT OF A SYSTEM COMMUNICATION FAILURE WITH THE BACKBONE NETWORK OR THE MANAGEMENT SOFTWARE BECOMING UNAVAILABLE. 5. EACH DEVICE OR ZONE SHALL BE ADDRESSABLE AND SHALL INCLUDE ON/OFF, FADE, DIMMING, SCENE SETTINGS, AND OTHER STANDARD CONTROL FUNCTIONS AS REQUIRED TO MEET THE LIGHTING CONTROL SCHEDULE FUNCTIONS. OCCUPANCY SENSORS SHALL BE CEILING-MOUNTING, SOLID-STATE, LOW VOLTAGE UNITS COMPLYING WITH THE REQUIREMENTS LISTED BELOW; A. OPERATION: UNLESS OTHERWISE INDICATED, TURN LIGHTS ON WHEN COVERED AREA IS OCCUPIED AND OFF WHEN UNOCCUPIED; WITH A TIME DELAY FOR TURNING LIGHTS OFF ADJUSTABLE OVER A MINIMUM RANGE OF 1 TO 20 MINUTES. AUTOMATIC SENSITIVITY ADJUSTMENT. B. SENSOR TYPE: SENSORS SHALL BE DUAL-TECHNOLOGY TYPE (UNLESS NOTED OTHERWISE). PASSIVE INFRARED TYPE SENSORS ARE ACCEPTABLE WITHIN CORRIDORS AND VESTIBULES. C. SENSOR OUTPUT: CONTACTS RATED TO OPERATE THE CONNECTED POWER PACK, COMPLYING WITH UL 773A. SENSOR SHALL BE POWERED FROM THE POWER PACK. D. MOUNTING: SENSOR SHALL BE SUITABLE FOR MOUNTING ON A STANDARD OUTLET BOX. E. TIME-DELAY AND SENSITIVITY ADJUSTMENTS: RECESSED AND CONCEALED BEHIND ACCESSIBLE COVER. F. SELECT, INSTALL, AND AIM SENSORS TO ACHIEVE NOT LESS THAN 90 PERCENT COVERAGE OF AREAS SERVED. 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 NO SCALE Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/23/2024 4:04:42 PM 1/23/2024 4:04:42 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt E001 01/24/2024 23289 ELECTRICAL SPECIFICATIONS KDD RJA © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 11/08/2024 NC NC J CR S F J D D A. THE INTENT OF THE DEMOLITION DRAWINGS IS TO DEFINE THE SCOPE OF ELECTRICAL DEMOLITION WORK.EXISTING ELECTRICAL SYSTEMS (DEVICES, FIXTURES, EQUIPMENT, WIRING, AND RACEWAYS INCLUDING DATA/COMMUNICATION SYSTEMS). EXISTING ELECTRICAL SYSTEMS SERVING ADJACENT AREAS SHALL REMAIN UNLESS OTHERWISE INDICATED. RE-SUPPORT EXISTING CONDUITS AND CABLES THAT MUST REMAIN. PROVIDE DEMOLITION FOR ITEMS AS SHOWN. EXISTING ELECTRICAL SYSTEMS WITHIN LIMITS OF DEMOLITION SHALL REMAIN UNLESS OTHERWISE INDICATED. B. ITEMS INDICATED WITH A SUBSCRIPT 'E' SHALL BE EXISTING TO REMAIN (E-EXISTING). ITEMS INDICATED WITH A SUBSCRIPT 'D' OR SHOWN DASHED SHALL BE REMOVED (D-DEMOLITION). ITEMS INDICATED WITH A SUBSCRIPT 'R' SHALL BE REMOVED, STORED, AND REINSTALLED PER NEW WORK (R-RELOCATION). C. THESE DRAWINGS DO NOT IDENTIFY EACH INDIVIDUAL ITEM TO BE REMOVED. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING ITEMS WHICH MUST BE REMOVED TO FACILITATE NEW CONSTRUCTION. SEE ARCHITECTURAL PLANS FOR EXACT LIMITS OF DEMOLITION AND CONSTRUCTION. THESE PLANS ARE BASED ON PAST PROJECT DRAWINGS AND SITE OBSERVATIONS. THE DRAWINGS ARE PROVIDED TO THE CONTRACTOR AS AN AID IN DETERMINING THE EXTENT OF WORK REQUIRED FOR DEMOLITION AND TO PROVIDE GENERAL INFORMATION ABOUT EXISTING SYSTEMS. THESE DRAWINGS MAY NOT BE ACCURATE IN ALL AREAS. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND IS ENCOURAGED TO REVIEW FACILITY DRAWINGS PRIOR TO THE BID DATE. D. THE OWNER SHALL HAVE FIRST SALVAGE RIGHTS TO ALL ITEMS REMOVED. IF OWNER REFUSES SALVAGE, CONTRACTOR IS RESPONSIBLE FOR DISPOSAL. E. WHERE EXISTING WALLS ARE TO BE REMOVED, ALL ASSOCIATED ELECTRICAL EQUIPMENT SHALL BE REMOVED. DISCONNECT POWER SO THAT DEVICES AND EQUIPMENT MAY BE REMOVED WITH WALLS. SEE ARCHITECTURAL DRAWINGS FOR WALLS TO BE REMOVED. ABANDON CONCEALED CONDUITS WHERE WALLS ARE NOT REMOVED. CONCEALED CONDUITS MAY BE REUSED WHERE AVAILABLE. WHERE EXISTING CIRCUITING/CABLING IS TO BE DEMOLISHED AND NOT REUSED, REMOVE CONDUCTORS AND ASSOCIATED ACCESSIBLE RACEWAYS/CONDUIT BACK TO THE SOURCE. WHERE EXISTING ELECTRICAL CONDUITS SERVING CIRCUITS TO BE DEMOLISHED ARE EMBEDDED IN CONCRETE FLOORS OR WALLS, CONDUITS MAY BE ABANDONED IN PLACE. EXISTING CONDUCTORS SHALL BE REMOVED BACK TO SOURCE AND CONDUITS SHALL BE CUT AT SURFACE OF CONCRETE AND FILLED. EXISTING BACK BOXES AND CONDUITS REMAINING FROM DEVICES BEING REMOVED MAY BE UTILIZED FOR NEW DEVICES WHERE LOCATIONS PERMIT. REMOVE AND PATCH WHERE BOXES ARE NOT REUSED. REMOVE CONCRETE EQUIPMENT PADS THAT REMAIN, TO BE FLUSH WITH FLOOR/GRADE. (ELECTRICAL DEMOLITION NOTES APPLY TO ALL ELECTRICAL DEMOLITION PLANS AND ALL ELECTRICAL DEMOLITION WORK) ELECTRICAL DEMOLITION GENERAL NOTES: F. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL ELECTRICAL DEMOLITION ITEMS. DISCONNECT AND REMOVE ELECTRICAL DEVICES, EQUIPMENT AND ASSOCIATED WIRING AS REQUIRED TO ACCOMMODATE NEW WORK. IF THE CONTRACTOR IS UNCLEAR REGARDING A SPECIFIC ITEM TO REMAIN OR BE REMOVED, THE CONTRACTOR SHALL SEEK CLARIFICATION FROM THE ARCHITECT. G. SYSTEMS SERVING ADJACENT AREAS AND ITEMS THAT REMAIN SHALL BE MAINTAINED AT ALL TIMES. MODIFY SYSTEMS AS REQUIRED THROUGHOUT CONSTRUCTION TO MAINTAIN CONTINUITY OF SERVICE. DO NOT INTERRUPT SERVICE WITHOUT OWNER'S PRIOR WRITTEN APPROVAL. LIMIT DURATION OF INTERRUPTION ONLY TO THE TIME NECESSARY FOR DISCONNECTION AND IMMEDIATE RECONNECTION. INTERRUPTION TO SERVICE DEEMED BY OWNER AS ESSENTIAL MAY REQUIRE PREMIUM TIME AND SHALL BE INCLUDED WITH THE BID. EXTREME CARE SHALL BE TAKEN BY THE CONTRACTOR TO IDENTIFY EXISTING SYSTEM COMPONENTS ASSOCIATED WITH THESE SERVICES. APPROPRIATE METHODS OF MARKING THESE SHALL OCCUR TO ELIMINATE THE POSSIBILITY OF ACCIDENTAL INTERRUPTION. FOR CONDUIT AND CABLING THAT CAN REMAIN, PROVIDE SUPPORT AS REQUIRED. RELOCATE EXISTING JUNCTION BOXES THAT BECOME INACCESSIBLE DUE TO NEW WORK. H. COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES. PROVIDE TEMPORARY POWER AND LIGHTING AS REQUIRED TO ALLOW THE WORK OF OTHER TRADES TO PROCEED. I. PROTECT EXISTING ELECTRICAL EQUIPMENT THAT REMAINS. IF DAMAGED OR DISTURBED IN THE COURSE OF THE WORK, REMOVE DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF EQUAL CAPACITY, QUALITY, AND FUNCTIONALITY. J. PATCH AND REPAIR OPENINGS IN EXISTING WALLS AND FLOORS RESULTANT FROM SPECIFIED ELECTRICAL DEMOLITION. PATCH SHALL MATCH EXISTING CONSTRUCTION, FIRE RATING, AND FINISH. SEE ARCHITECTURAL SPECIFICATIONS FOR MEANS AND METHODS. K. ALL UNLABELED ELECTRICAL DEVICES WITH CIRCUITRY OR DEVICES MODIFIED DURING CONSTRUCTION SHALL BE CIRCUIT TRACED AS NEEDED WITH A LABEL PROVIDED. 19 Q P O P.9 AA 19.4 20 21 21.4 22 22.8 23 24 25 25.4 E D D E E D E E D D D D D ED E D D D D D D E D D D E E E E E E E D E E D D D D D D D D D D D D D D D D D D D D D R E D R R E R DD D E D D D D D D D D E D E E D D 3 3DD CODE E D E D R D R D E D D CODE D 1 2 2 2 2 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/4" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/23/2024 4:04:42 PM 1/23/2024 4:04:42 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt E101 01/24/2024 23289 ELECTRICAL DEMOLITION KDD RJA © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . SHEET NOTES: 1. REPLACE EXISTING RECEPTACLE WITH NEW GFI RECEPTACLE IN THE SAME LOCATION. MAINTAIN EXISTING CIRCUITING. 2. REMOVE EXISTING LIGHT FIXTURES AS SHOWN. PROTECT EXISTING CRITICAL CIRCUIT FOR REUSE. 1/4" = 1'-0"1 LEVEL 01 - DEMOLITION - ELECTRICAL 11/08/2024 19 Q P O P.9 AA 19.4 20 21 21.4 22 22.8 23 24 25 25.4 E E E E E N.M .TECH 1612 N.M. / CT IMAGING 1622 DIRECTOR OF MARKETING (EXISTING) X72 STORAGE (EXISTING) 1809 GENERAL COUNSELOR (EXISTING) X74 STRESS TEST (EXISTING) 1611 HALL (EXISTING) X101 N.M. WAITING (EXISTING) 1614 CHECK-IN/ WAITING (EXISTING) 1601 LOCKERS (EXISTING) 1610 CHECK-IN/ WAITING (EXISTING) 1601 ADMIN ASSISTANT (EXISTING) X70 CEO OFFICE (EXISTING) X75 DIAGNOSTICS (EXISTING) 1603 D1 b D1 b D1 b D1 b D1 b D1 b D1 b A1 A1 A1 A1 A1 A1 2D 2D WD C1 a 2D C1 aPRO FA5 FA5 CRH1C-3 1 L1D-59 L1D-59 3 3 2 c c dd U1 U1 X12 L1D-44 L1D-44 L1D-57 L1D-57 X1 4 D1 b D1 b (LIGHTING CONTROL GENERAL NOTES SHALL APPLY TO ALL SHEETS) A. LIGHTING CONTROL DEVICES ARE INDICATED WITHOUT CONNECTION TO FIXTURE(S) BEING CONTROLLED. WITHIN EACH AREA, CONNECT CONTROL DEVICE TO SERVE LIGHT FIXTURE(S) LOCATED WITHIN SAME AREA. WHERE LIGHT FIXTURES ARE INDICATED WITH A SUBSCRIPT LETTER IDENTIFYING INDIVIDUAL LIGHTING CONTROL ZONES, CONTROL DEVICE SERVING AREA WITH MATCHING SUBSCRIPT SHALL CONTROL CORRESPONDING LIGHT FIXTURES. B. LIGHTING CONTROL DEVICE MOUNTING HEIGHTS ARE NOT INDICATED ON ELECTRICAL FLOOR PLANS. CONTRACTOR SHALL COORDINATE EXACT DEVICE LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTURAL INTERIOR ELEVATIONS. WHERE DEVICE MOUNTING HEIGHTS ARE NOT INDICATED PER ARCHITECT, MOUNT DEVICES AT HEIGHT INDICATED IN ELECTRICAL PROJECT SPECIFICATIONS. C. CONTRACTOR SHALL COORDINATE ALL LIGHTING CONTROL DEVICE ROUGH-IN LOCATIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS TO ASSURE COMPATIBILITY WITH FINISHES SPECIFIED ON THE ARCHITECTURAL DRAWINGS. COORDINATE ROUTING OF ALL ELECTRICAL BRANCH CIRCUITS AND CONDUIT WITH OTHER TRADES TO ALLOW FOR SERVICE AND MAINTENANCE AND TO MINIMIZE THE USE OF ACCESS PANELS. WHERE ACCESS PANELS CANNOT BE AVOIDED, WORK TO INSTALL PANELS IN LOCATIONS ACCEPTABLE TO ARCHITECT. D. REFER TO DETAILS, SCHEDULES, AND SYMBOL LEGENDS FOR ADDITIONAL REQUIREMENTS. E. REFER TO LUMINAIRE SCHEDULE FOR LUMINAIRE DETAILS. LIGHTING GENERAL NOTES: A. SUBMIT MANUFACTURER INTERCONNECTION DIAGRAMS INDICATING DEVICE QUANTITIES, LOCATIONS, AND ASSOCIATED CONTROLS CABLING FOR APPROVAL. B. WHERE TOTAL SYSTEM COST (INCLUDING INSTALLATION) OF A WIRELESS AND/OR LUMINAIRE LEVEL LIGHTING CONTROL SYSTEM IS LESSER THAN A WIRED SYSTEM WHILE PROVIDING THE SAME FUNCTIONALITY, THAT SYSTEM MAY BE PROVIDED. C. SUBMIT DOCUMENTATION CONFIRMING CONTROL SYSTEM’S ABILITY TO COMPLY WITH SPECIFIED LIGHTING CONTROL SEQUENCE OF OPERATIONS. CLEARLY IDENTITY ANY CONTROL DEVIATIONS NECESSARY DUE TO SUBMITTED CONTROL SYSTEMS FUNCTIONALITY, ALONG WITH PROPOSED SEQUENCE OF OPERATIONS. D. DEVICE QUANTITIES NOT INDICATED. PROVIDE TYPE AND QUANTITY OF DEVICES AS REQUIRED TO PROVIDE COMPLETE COVERAGE OF SPACE AND INTENDED SYSTEM OPERATION. E. REFER TO LIGHTING CONTROL PLAN FOR WALL DEVICE TYPES, QUANTITIES, AND LOCATIONS. REFER TO LIGHTING CONTROL WALL DEVICE SCHEDULES FOR WALL DEVICE CONFIGURATION, OPERATION, AND LABELING. F. UNLESS NOTED OTHERWISE, LIGHTING SHALL UTILIZE CONTINUOUS DIMMING. COORDINATE DIMMER TYPE (FORWARD PHASE, REVERSE PHASE, 0-10V) AND DIMMER COMPATIBILITY WITH SUBMITTED LUMINAIRE AND LIGHTING CONTROL MANUFACTURER. G. PROVIDE ALL 0-10V CONTROL WIRING AND SYSTEM PROGRAMMING NECESSARY FOR THE DIMMING AND CONTROL OF LUMINAIRES AS SPECIFIED IN THE LIGHTING CONTROL SEQUENCE OF OPERATIONS. H. UNDERCABINET LIGHTING SHALL BE SWITCHED SEPARATELY FROM MAIN ROOM LIGHTING. UNDERCABINET LIGHTING SHALL BE CONTROLLED BY THE AUTO OFF FUNCTION OF OCCUPANCY SENSORS. I. PROVIDE FUNCTIONAL TESTING OF LIGHTING CONTROLS THAT COMPLIES WITH IECC 2018 REQUIREMENTS. LIGHTING CONTROL FUNCTIONAL TESTING INCLUDES TESTING FOR PROPER CALIBRATION, ADJUSTMENT, PROGRAMING AND WORKING CONDITION. TESTING INDIVIDUAL SHALL NOT BE INVOLVED WITH PROJECT DESIGN OR CONSTRUCTION AND MUST PROVIDE CERTIFYING DOCUMENT THAT LIGHTING CONTROLS MEET THE PERFORMANCE CRITERIA. LIGHTING CONTROL SYSTEM GENERAL NOTES: 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # INSTALL GREEN INSULATED GROUND WIRE WITH LIGHTING, RECEPTACLE AND EQUIPMENT BRANCH CIRCUITS. INSTALL INDIVIDUAL (DEDICATED) NEUTRAL CONDUCTORS FOR EACH 120V OR 277V PHASE CONDUCTOR SERVED FROM A SINGLE POLE CIRCUIT BREAKER Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/4" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/23/2024 4:04:44 PM 1/23/2024 4:04:44 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt EL201 01/24/2024 23289 NEW FLOOR PLAN - LIGHTING KDD RJA © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . SHEET NOTES: 1. CONNECT NEW LIGHTING TO EXISTING CRITICAL CIRCUIT PREVIOUSLY SERVING THIS ROOM. LOAD ADDED IS LESS THAN LOAD REMOVED. 2. CONNECT IN-USE WARNING LIGHT TO NEW EQUIPMENT PER GE REQUIREMENTS. PROVIDE DEDICATED NEUTRAL AS REQUIRED. 3. CONNECT TO EXISTING SPARE CIRCUIT BREAKER. 4. CONNECT TO EXISTING LIFE SAFETY CIRCUIT AS SHOWN. LIGHT FIXTURE SHALL OPERATE 24/7. 1/4" = 1'-0"1 LEVEL 01 - NEW PLAN - LIGHTING 11/08/2024 NC J S F CR CR J F NC A. ELECTRICAL DEVICE MOUNTING HEIGHTS ARE NOT INDICATED ON ELECTRICAL FLOOR PLANS. CONTRACTOR SHALL COORDINATE EXACT DEVICE LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTURAL INTERIOR ELEVATIONS. WHERE DEVICE MOUNTING HEIGHTS ARE NOT INDICATED PER ARCHITECT, MOUNT DEVICES AT HEIGHT INDICATED IN ELECTRICAL PROJECT SPECIFICATIONS. B. CONTRACTOR SHALL COORDINATE ALL ELECTRICAL DEVICE ROUGH-IN LOCATIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS TO ASSURE COMPATIBILITY WITH FINISHES SPECIFIED ON THE ARCHITECTURAL DRAWINGS. ROUTE ALL ELECTRICAL BRANCH CIRCUITS AND CONDUITS SPECIFIED, TO COORDINATE WITH OTHER TRADES AND TO ALLOW FOR SERVICE AND MAINTENANCE AND TO MINIMIZE THE USE OF ACCESS PANELS. WHERE ACCESS PANELS CANNOT BE AVOIDED, ARRANGE WORK TO INSTALL PANELS IN LOCATIONS ACCEPTABLE TO ARCHITECT. C. REFER TO DETAILS, SCHEDULES, AND SYMBOL LEGENDS FOR ADDITIONAL REQUIREMENTS. D. REDUNDANT GROUNDING METHODS REQUIRED FOR PATIENT CARE AREAS. REFER TO NEC FOR REQUIREMENTS AND TO PROJECT SPECIFICATIONS FOR ACCEPTABLE METHODS/APPLICATIONS. E. GFCI TYPE RECEPTACLES ARE NOTED AS SUCH ON THE PLANS FOR PRICING PURPOSES. HOWEVER, CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE ALL RECEPTACLES INSTALLED WHERE A 6' CORD LENGTH COULD REACH THE EDGE OF A SINK HAVE GFCI PROTECTION. (POWER GENERAL NOTES SHALL APPLY TO ALL SHEETS) POWER GENERAL NOTES: 19 Q P O P.9 AA 19.4 20 21 21.4 22 22.8 23 24 25 25.4 R R R D R D R N.M. / CT IMAGING 1622 N.M .TECH 1612 CONTRAST MEDIA PREP AREA-2 1613-2 N.M .TECH 1612 STRESS TEST (EXISTING) 1611 HALL (EXISTING) X101 STORAGE (EXISTING) 1809 GENERAL COUNSELOR (EXISTING) X74 DIRECTOR OF MARKETING (EXISTING) X72 ADMIN ASSISTANT (EXISTING) X70 N.M. WAITING (EXISTING) 1614 E 44" E 44" E E D E E E E E E E E E E CODE E E E E E E R EPO IMG 1 2 2 3MDP 4 CRL1D-69 5 44" 44" L1D-44 44" L1D-63 L1D-636 6 4 L1D-47 57 H-2 H-1 STF ? 1 A. COORDINATE THE LOCATIONS AND CONTROLS OF ALL FIRE/SMOKE DAMPERS WITH MECHANICAL CONTRACTOR PRIOR TO WORK. (LOW VOLTAGE GENERAL NOTES SHALL APPLY TO ALL SHEETS) LOW VOLTAGE GENERAL NOTES: 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/4" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 5/7/2024 12:08:46 PM 5/7/2024 12:08:46 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt EP201 01/24/2024 23289 NEW FLOOR PLAN - POWER & LOW VOLTAGE KDD RJA © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . SHEET NOTES: 1. PROVIDE RACEWAYS FOR NUCLEAR MEDICINE EQUIPMENT. REFER TO ENLARGED POWER PLAN AND GE EQUIPMENT DRAWINGS FOR ADDITIONAL INFORMATION AND CONTRACTOR RESPONSIBILITIES. COORDINATE WITH EQUIPMENT INSTALLER. 2. REPLACE EXISTING RECEPTACE WITH NEW GFI RECEPTACLE IN THE SAME LOCATION. MAINTAIN EXISTING CIRCUITING. 3. 90-AMP MAIN DISCONNECT PANEL (MDP), PROVIDED BY GE. REFER TO ENLARGED POWER PLAN AND GE EQUIPMENT DRAWINGS FOR ADDITIONAL INFORMATION AND CONTRACTOR RESPONSIBILITIES. COORDINATE WITH EQUIPMENT INSTALLER. REFER TO ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION. 4. TIE INTO EXISTING CIRCUIT AS SHOWN. 5. CONNECT TO EXISTING SPARE CIRCUIT BREAKER. 6. CONNECT TO EXISTING CIRCUIT. LOAD ADDED IS EQUAL OR LESS THAN LOAD REMOVED. 7. PROVIDE 120V CONNECTION TO NEW CONTRAST INJECTOR. CONFIRM LOCATION AND REQUIREMENTS WITH OWNER AND APPROVED EQUIPMENT SUBMITTALS PRIOR TO ROUGH-IN. 1/4" = 1'-0"1 LEVEL 01 - NEW PLAN - POWER & LOW VOLTAGE 1 05/07/2024 NM RFI 1 11/08/2024 A. VENDOR DRAWINGS SHOWN FOR REFERENCE. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT VENDOR. B. PROVIDE ALL ITEMS INDICATED FOR A COMPLETE ELECTRICAL INSTALLATION OF X-RAY EQUIPMENT. IMAGING EQUIPMENT PLAN GENERAL NOTES: 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 NO SCALE Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/23/2024 4:04:43 PM 1/23/2024 4:04:43 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt E300 01/24/2024 23289 ENLARGED POWER PLAN KDD RJA © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . 11/08/2024 A. MECHANICAL EQUIPMENT NOT SHOWN ON ONE-LINE. REFER TO PANEL SCHEDULES FOR COMPLETE LIST OF CIRCUIT BREAKER SIZES AND QUANTITIES REQUIRED. (GENERAL NOTES SHALL APPLY TO ALL ONE-LINE SHEETS) ONE-LINE GENERAL NOTES: ESSENTIAL MAIN DISTRIBUTION SWITCHBOARD "EMDS" 3000A, 480Y/277V, 3Ø, 4W, 65KAIC 1200A TO PORTABLE GEN./LOAD BANK TAPBOX ON EXTERIOR 1000A 800A SPARE 200A 250A SPARE 800A 400A 600A ATS-CR2 600A 800A 1000A 1000A 100A 40A 200A 400A 400A 400A 400A CRITICAL SUB-DISTRIBUTION PANEL "CSDH1A" 600A, 480Y/277V, 3Ø, 4W, 65KAIC 1000A SPARE TO "ATS-E1" TO GENERATOR 600KW, 750KVA (520KW, 650KVA AT ELEVATION) TO GENERATOR 600KW, 750KVA (520KW, 650KVA AT ELEVATION) TO "ATS-E2" 15A 30A 50A 70A NORMAL SUB DISTRIBUTION SWITCHBOARD "NSDH1B" (PARTIAL) 600A, 480Y/277V, 3Ø, 4W, 35KAIC 1200A 600A 600A 4000A GFCI 400A 400A 1200A 600A 600A 250A 250A 1000A 100A 1200A SPACE UTILITY METER SPARE TO "NSDHBA" TO "ATS-LS" SPARE SPARE TO "ATS-E2" NORMAL MAIN DISTRIBUTION SWITCHBOARD "MDS" 4000A, 480Y/277V, 3Ø, 4W, 65KAIC SPARESPARE TO "ATS-E1" TO "H-1" UTILITY TRANSFORMER TO "NSDH1A" TO "ELEVATOR" (E) L1D TX-L1D 75KVA TO "VAC-E" TO "UPS" TO "ATS-E3" 200A 100A 125A 200A 200A 20A 100A SPARE TO "CRH1D" 45A TO "LEH" SPARE TO "CRH1A" TO "CRH2A" (E) CRH1C (E) CRL1D1 TX-L1D 75KVA (E) CRL1D SPARE SPARE TO "CSDHBA" CRITICAL SUB-DISTRIBUTION PANEL "CSDH1B" 400A, 480Y/277V, 3Ø, 4W, 35KAIC TO "CRL1M" TO "ATS-CR3" TO "ATS-LS" 90A 9 200A 150A 150A 150A TO "H2A" TO "H1A" 110A TO "PH-6" SPARE TO "H1F" SPARE 90A/3P MDP PROVIDED BY GE 1ISCA=29,110 ISCA=9,874 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 NO SCALE Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 5/7/2024 12:08:44 PM 5/7/2024 12:08:44 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt E500 01/24/2024 23289 ONE-LINE DIAGRAM KDD RJA © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . FEEDER SCHEDULE - COPPER FEEDER NOMINAL SIZE WIRE AND CONDUIT 9 90 A 3-#2 CU, #1/0 CU GND - 1-1/2" C. LOAD JUSTIFICATION SCHEDULE EQUIPMENT DATA LOADS REMOVED LOADS ADDED NET CHANGE CAPACITY ANALYSIS PANEL NAME VOLTAGE AMPS CAPACITY # OF PHASES # OF WIRES RECEPTACLE LOAD REMOVED LIGHTING LOAD REMOVED LIGHTING DEMAND FACTOR EQUIPMENT LOAD REMOVED TOTAL LOAD REMOVED RECEPTACLE LOAD ADDED LIGHTING LOAD ADDED LIGHTING DEMAND FACTOR EQUIPMENT LOAD ADDED TOTAL LOAD ADDED NET LOAD CHANGE NET AMPS AT 3PH VOLTAGE PEAK DEMAND AMPS METERING METERING DEMAND FACTOR METERING DESCRIPTION REMAINING CAPACITY CRH1C 480 V 200 A 3 4 0 VA 483 VA 1.25 0 VA 604 VA 0 VA 310 VA 1.25 0 VA 388 VA -216 VA 0 A 0 A 1.25 200 A CRL1D 208 V 250 A 3 4 1260 VA 0 VA 1.25 0 VA 1260 VA 720 VA 0 VA 1.25 0 VA 720 VA -540 VA -1 A 0 A 1.25 251 A L1D 208 V 250 A 3 4 1260 VA 40 VA 1.25 4000 VA 5310 VA 1080 VA 82 VA 1.25 300 VA 1483 VA -3828 VA -11 A 0 A 1.25 261 A NSDH1B 480 V 600 A 3 4 0 VA 0 VA 1.25 4000 VA 4000 VA 0 VA 0 VA 1.25 72000 VA 72000 VA 68000 VA 82 A 313 A 1.25 EXISTING DRAWINGS 127 A NO SCALEE500 ELECTRICAL ONE-LINE1 SHEET NOTES: 1. REPLACE (3) 20A/1P SPARE BREAKERS WITH A NEW 90A/3P BREAKER. NEW BREAKER TO MATCH EXISTING BREAKER MANUFACTURER, TYPE AND AIC RATING. 1 05/07/2024 NM RFI 1 1 11/08/2024 NOTES: 1. COORDINATE DEVICE MOUNTING HEIGHTS WITH ARCHITECT AND ARCHITECTURAL DETAILS. MOUNTING HEIGHTS INDICATED ABOVE ARE TO BE UTILIZED FOR DEVICES NOT DETAILED BY ARCHITECT. 2. WHERE DEVICES SHOWN ON PLAN ARE NOTED WITH AN EQUIPMENT TAG, COORDINATE EXACT LOCATION AND ELEVATION TO DIRECTLY SERVE EQUIPMENT. 3. COORDINATE DEVICE LOCATIONS TO BE 12" MINIMUM FROM ALCOHOL ANTISEPTIC DISPENSERS. FIRE ALARM PULL STATION FIRE 48" WALL MOUNTED FIRE ALARM NOTIFICATION DEVICES CENTERED ABOVE LIGHT SWITCH IF LOCATED IN THAT AREA (WHERE SHOWN AS WALL MOUNT) FOR STROBES, DIMENSION TO CENTER OF STROBE 82" FIRE 60" MAX MAGNETIC DOOR HOLDER 3" MIN CEILING MOUNTED HEAT OR SMOKE DETECTOR ACCEPTABLE HERE NEVER HERE ACCEPTABLE HERE DUCT AIRFLOW TUBE SUPPORT HOLE ONLY FOR DUCTS MORE THAN 36" WIDE RETURN TUBE SLANT CUT FACE ORIENTED DOWNSTREAM OF AIRFLOW FINISHED CEILING; IF HARD CEILING, MUST HAVE ACCESS PANEL MOUNT ON BOTTOM (PREFERRED OR TOP WITH SAMPLING TUBES VERTICAL INLET TUBE HOLES FACE UPSTREAM OF AIRFLOW INSERT A PLUG IN THIS END OF INLET TUBE (MUST HAVE PLUG INSERTED AND AROUND PIPE DUCT SEAL) 4" MIN 36" MIN ACCESS PANEL OR TILE IN GRID 4" MIN 12" MAX SUPPLY AND RETURN AIRFLOW NOTES: 1. COORDINATE DEVICE MOUNTING HEIGHTS WITH ARCHITECT AND ARCHITECTURAL DETAILS. MOUNTING HEIGHTS INDICATED ABOVE ARE TO BE UTILIZED FOR DEVICES NOT DETAILED BY ARCHITECT. 2. ELEVATIONS SHOWN ARE FROM FINISHED FLOOR OR SURFACE TO CENTER LINE OF DEVICE. (EXCEPT WHERE INDICATED OTHERWISE) 3. WHERE DEVICES SHOWN ON PLAN ARE NOTED WITH AN EQUIPMENT TAG, COORDINATE EXACT LOCATION AND ELEVATION TO DIRECTLY SERVE EQUIPMENT. 4. WHERE DEVICES SERVE MOVEABLE EQUIPMENT, MOUNT DEVICES BEHIND EQUIPMENT. DEVICES SERVING FIXED EQUIPMENT SHALL BE LOCATED ADJACENT TO EQUIPMENT OR BEHIND EQUIPMENT WHERE ACCESS FOR DISCONNECTION CAN BE MAINTAINED. 5. IF DEVICES ARE SHOWN TO EXCEED 44" AFF AT COUNTERS AND WORK SURFACES, NOTIFY ARCHITECT REGARDING ADA REQUIREMENTS PRIOR TO INSTALLATION. 6. COORDINATE DEVICE LOCATIONS TO NOT BE DIRECTLY ABOVE OR BELOW ALCOHOL ANTISEPTIC DISPENSERS.VERIFY DISPENSER LOCATIONS WITH OWNER. DEVICES WITHIN SHELVING ONLY WHERE SPECIFICALLY NOTED COORDINATE EXACT ELEVATION WITH SHELF LOCATION UNDER-COUNTER EQUIPMENT 18" DEVICES SERVING EQUIPMENT LOCATED IN KNEE SPACE KNEE SPACE DISPOSER RECEPTACLE OR SENSOR OPERATED PLUMBING CONNECTION (LOCATE CONCEALED FROM VIEW IF NOT ENCLOSED BY CABINET) BACKSPLASH COUNTERTOP RECEPTACLE REFER TO FLOOR PLANS AND ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS ABOVE COUNTERS AND WORK SURFACES 4" DISPOSER OR LIGHT SWITCH 4" 6' 120V RECEPTACLES WITHIN 6' OF SINK EDGE SHALL BE GFCI TYPE OVERHEAD EQUIPMENT DEVICES WITHIN SHELVING ONLY WHERE SPECIFICALLY NOTED COORDINATE EXACT ELEVATION WITH SHELF LOCATION 12" MAX REFER TO FLOOR PLANS AND ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS ABOVE AND BEHIND FILING CABINETS LOCATE DEVICES ADJACENT TO OR DIRECTLY BELOW EQUIPMENT AS COORDINATED WITH OWNER WALL MOUNTED EQUIPMENT (COORDINATE WITH MOUNTING ELEVATION OF EQUIPMENT) 4" 48" WALL MOUNTED NURSE CALL DOME LIGHTS CENTERED ABOVE DOOR OPENING (CEILING MOUNT IF INSUFFICIENT WALL SPACE) WALL PHONE PUSH BUTTON, CONTROL STATIONS, MONITOR PANELS, ETC LIGHT SWITCH NURSE CALL ON OPEN WALL SPACE CONVENIENCE DEVICES ON OPEN WALL SPACE 18" ALIGN TO COUNTERTOP RECEPTACLES WHEN LOCATED ADJACENT TO COUNTERTOP RECEPTACLE PER PLAN PROVIDE WITH BUSHING PROVIDE 1" CONDUIT STUBBED UP ABOVE NEAREST ACCESSIBLE CORRIDOR CEILING PROVIDE 4" SQUARE BY 2-1/8" DEEP BOX WITH SINGLE GANG PLASTER RING PROVIDE PULL CORD PROVIDE AT PLAN SYMBOL TV OR MAXIMUM 12" BETWEEN BOX CENTERS UNLESS SPECIFICALLY NOTED OTHERWISE COORDINATE WITH ARCHITECTURAL DETAILS PROVIDE 3/4" CONDUIT STUBBED UP ABOVE NEAREST ACCESSIBLE CORRIDOR CEILING PROVIDE 4" SQUARE BY 2-1/8" DEEP BOX WITH SINGLE GANG PLASTER RING PROVIDE AT PLAN SYMBOL CR FINISHED CEILING PROVIDE WITH CONDUIT BUSHING (TYPICAL) ATTACH CONDUIT TO TRAY WITH MANUFACTURER'S SECURING COUPLING (TYPICAL) PROVIDE PULL CORD (TYPICAL) NOTES: 1. REFER TO SECURITY DEVICE SYMBOL LEGEND FOR ADDITIONAL REQUIREMENTS. 2. COORDINATE EXACT LOCATION OF CARD READER WITH ARCHITECT, ARCHITECTURAL INTERIOR ELEVATIONS, AND OTHER DOOR COMPONENTS. 3. COORDINATE REQUIRED CONDUITS TO DOOR FRAME AND WALL MOUNTED DEVICES WITH DOOR HARDWARE CONTRACTOR AND DOOR HARDWARE SCHEDULE. PROVIDE 3/4" CONDUIT STUBBED UP ABOVE NEAREST ACCESSIBLE CORRIDOR CEILING AS REQUIRED PER DOOR HARDWARE SCHEDULE AC OR 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 NO SCALE Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 1/23/2024 4:04:44 PM 1/23/2024 4:04:44 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt E600 01/24/2024 23289 ELECTRICAL DETAILS KDD RJA © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . NO SCALEE600 TYPICAL FIRE ALARM MOUNTING HEIGHTS4 NO SCALEE600 TYPICAL ELECTRICAL DEVICE MOUNTING HEIGHTS3 NO SCALEE600 COMMUNICATIONS OUTLET - STUB TO CORRIDOR 1 NO SCALEE600 ACCESS CONTROL ROUGH-IN2 11/08/2024 REMARKS: (LIGHTING FIXTURE SCHEDULE) 1. RIBBON -COORDINATE EXACT LENGTHS WITH ARCHITECTURAL DETAILS TO PROVIDE CONTINUOUS ILLUMINATION BEHIND FABRIC CEILING. REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION. 2. WARNING LIGHT SHALL BE TIED TO THE IMAGING EQUIPMENT PER THE MANUFACTURER'S REQUIREMENTS. PROVIDE CONTROLLER AND ALL COMPONENTS FOR AN OPERATIONAL SYSTEM. GENERAL NOTES: (LIGHTING FIXTURE SCHEDULE) A. CATALOG NUMBER VERIFICATION -CONTRACTOR SHALL VERIFY LIGHTING FIXTURE INSTALLATION REQUIREMENTS AND CATALOG NUMBER PRIOR TO ORDERING. B. SUBSTITUTIONS -WHERE INDICATED WITH 'N' (NO), NO SUBSTITUTIONS WILL BE ACCEPTED. WHERE INDICATED WITH 'P' (PRIOR APPROVAL), SUBSTITUTIONS MUST BE APPROVED PRIOR TO BID WITH ACCEPTANCE ISSUED BY ADDENDUM. WHERE INDICATED WITH 'Y' (YES), THE FOLLOWING MANUFACTURER'S ARE CONSIDERED ACCEPTABLE EQUIVALENT MANUFACTURER'S, PROVIDED THE EQUIVALENT FIXTURE IS OF THE SAME QUALITY, EFFICIENCY, PERFORMANCE AND CHARACTERISTICS AS THAT SCHEDULED: 1. ACUITY BRANDS 2. EATON/COOPER BRANDS 3. HUBBELL 4. PHILLIPS/SIGNIFY BRANDS C. DOWNLIGHT -PROVIDE DOWNLIGHT REFLECTOR FINISH/COLOR AS SPECIFIED IN THE LIGHTING FIXTURE SCHEDULE. SELECT CEILING TRIM FINISH/COLOR TO COORDINATE WITH CEILING TYPE. "WHITE" TRIM FOR DOWNLIGHTS MOUNTED IN WHITE ACOUSTICAL TILE CEILINGS. "CLEAR" (TO MATCH REFLECTOR FINISH/COLOR) FOR DOWNLIGHTS MOUNTED IN PAINTED GYPSUM BOARD CEILINGS. D. RIBBON –DRAWINGS PROVIDE GENERAL ILLUSTRATION OF RIBBON LAYOUT.COORDINATE EXACT UNIT LENGTHS AND QUANTITIES WITH ARCHITECTURAL DETAILS TO PROVIDE CONTINUOUS ILLUMINATION BEHIND FABRIC CEILING. LED RIBBON LIGHTING FIXTURES SHALL BE IN ROWS 12" APART (MAX) AND 6" (MAX) FROM EDGES.SELECT UNIT LENGTHS AND QUANTITIES TO ACHIEVE THE ABOVE REQUIRED PERFORMANCE. E. UNDERCABINET-PROVIDE ALL NECESSARY MANUFACTURER'S INSTALLATION ACCESSORIES TO ACCOMMODATE INSTALLATION, INCLUDING, BUT NOT LIMITED TO: SPLICE BOXES, END CONNECTORS, AND JUMPER/DAISY CHAIN CONNECTORS. GENERAL NOTES: (LIGHTING CONTROL SEQUENCE OF OPERATIONS) A. WHERE MULTIPLE CONTROL ZONES ARE INDICATED WITHIN A SPACE, THE ‘AUTO ON’AND ‘AUTO OFF’FUNCTIONS SHALL INCLUDE ALL CONTROL ZONES WITHIN THE SPACE UNLESS NOTED OTHERWISE. B. DAYLIGHT HARVESTING -REFER TO LIGHTING CONTROL PLAN FOR DAYLIGHT ZONES REQUIRING PHOTOCELL CONTROL AND THEIR ASSOCIATED LIGHTING SET POINTS. TARGET ILLUMINANCE LEVELS SHALL BE MEASURED AT THE WORK PLANE OF THE PRIMARY TASK WITHIN THE SPACE. C. OCCUPANCY SENSOR –PROVIDE OCCUPANCY SENSOR TYPE AS INDICATED BELOW. OCCUPANCY SENSORS SHALL BE CEILING MOUNTED. UNLESS SPECIFICALLY INDICATED OTHERWISE. REFER TO LIGHTING CONTROL WALL DEVICE SCHEDULE FOR WALL MOUNTED OCCUPANCY SENSOR SWITCHES. 1. SENSOR TYPE: • N = NO OCCUPANCY SENSOR(S) • IR = PASSIVE INFRARED • DT = DUAL-TECHNOLOGY 2. SENSOR OPTIONS: • F = FINE MOTION -CAPABLE OF DETECTING HAND MOTION • L = LARGE MOTION -CAPABLE OF DETECTING WALKING MOTION D. AUTO ON % -WHEN OCCUPANCY IS DETECTED WITHIN SPACE, ROOM LIGHTING SHALL BE TURNED ON TO SPECIFIED LIGHT LEVEL. WHERE INDICATED WITH ‘M’, ROOM SHALL BE MANUAL ON. E. AUTO OFF % -WHEN SPECIFIED SENSOR TIME DELAY IS REACHED, ROOM LIGHTING SHALL BE REDUCED TO SPECIFIED LIGHT LEVEL. WHERE INDICATED AS ZERO PERCENT, ROOM LIGHTING SHALL BE SWITCHED OFF. F. NETWORK –NETWORKED LIGHTING CONTROL SYSTEM INTERCOMMUNICATION: 1. Y = PROVIDE NETWORK COMMUNICATIONS BETWEEN CONTROL DEVICES LIGHTING CONTROL SYSTEM HEAD END 2. N = CONNECTION TO SYSTEM HEAD END NOT REQUIRED G. RECEPTACLE CONTROL –OCCUPANCY SENSOR CONTROL OF SELECTED ROOM RECEPTACLES: 1. Y = OCCUPANCY SENSOR SHALL SWITCH OFF INDICATED RECEPTACLES 20 MINUTES AFTER ALL OCCUPANTS HAVE VACATED SPACE 2. N = RECEPTACLE CONTROL NOT REQUIRED IN SPACE ON @ 100%, OFF KEYPAD ID DESCRIPTION REQUIRED BUTTON FUNCTIONS NO MARK SINGLE ZONE -ON/OFF ON @ 100%, RAISE, LOWER, OFF1DSINGLE ZONE - CONTINUOUS DIMMING ZONE 1 -ON @ 100%, RAISE, LOWER, OFF ZONE 2 -ON @ 100%, RAISE, LOWER, OFF2DTWO ZONE - CONTINUOUS DIMMING ON @ 100%, OFF INTEGRAL OCC. SENSOR [CONFIRM WITH CLIENT/OWNER PRIOR TO USE] W SINGLE ZONE -ON/OFF - WALL OCCUPANCY SENSOR ON @ 100%, RAISE, LOWER, OFF INTEGRAL OCC. SENSOR [CONFIRM WITH CLIENT/OWNER PRIOR TO USE] WD SINGLE ZONE -CONT. DIMMING -WALL OCCUPANCY SENSOR LIGHTING CONTROL WALL DEVICE SCHEDULE GENERAL NOTES (LIGHTING CONTROL DEVICE SCHEDULES): 1. 'ON' AND 'OFF' FUNCTIONS MAY BE COMBINED TO A SINGLE 'ON/OFF' BUTTON. 'RAISE' AND 'LOWER' FUNCTIONS MUST BE PROVIDED WITH DEDICATED BUTTONS, 'HOLD TO DIM' FUNCTIONALITY IS NOT ALLOWED. 2. SEE LIGHTING CONTROL SEQUENCE OF OPERATIONS FOR ADDITIONAL INFORMATION. 3. SUBMIT PROPOSED LOW VOLTAGE SWITCH BUTTON CONFIGURATIONS FOR ALL LOW VOLTAGE SWITCHES, CLEARLY IDENTIFYING ANY DEVIATIONS THAT NEED TO BE MADE DUE TO SWITCH CONFIGURATION OR ENGRAVING CONSTRAINTS FOR APPROVAL. IF SUBMITTED BUTTON CONFIGURATIONS DO NOT MEET DESIGN INTENT, ADDITIONAL LOW VOLTAGE SWITCHES MAY BE REQUIRED. 4. WHERE TASK TUNING LIGHT LEVELS ARE NOT SPECIFIED, 'ON' OR 'OCCUPIED' SHALL BE 100% OUTPUT WHILE 'OFF' OR 'UNOCCUPIED' SHALL BE 0% OUTPUT. F -FINE MOTION L -LARGE MOTION A -AUTO ON TO 100% P -PARTIAL AUTO ON M -MANUAL ON # -OCC. SENSOR DELAY (MINUTES) _ -NO SPECIAL T -TASK TUNING W -WHITE TUNING G -GERMICIDAL C -CIRCADIAN LIGHTING _ _ _ _ LIGHTING CONTROL SEQUENCE OF OPERATIONS GUIDE: -TAGS WILL RANGE FROM 3 CHARACTERS (<10 MINUTE DELAY, NO SPECIAL OPTIONS) TO 5 CHARACTERS (UP TO 20 MINUTE DELAY + SPECIAL): GENERAL NOTES: (EQUIPMENT CONNECTION SCHEDULE) A. EQUIPMENT LISTED MAY NOT BE UNIQUE, VERIFY QUANTITY WITH FLOOR PLANS. REFER TO DEFINITIONS BELOW FOR CLARIFICATIONS OF CONNECTION REQUIREMENTS. B. PROVIDE WIRING AND EQUIPMENT CONNECTIONS FOR INTERNAL EQUIPMENT COMPONENTS AS REQUIRED. COORDINATE REQUIREMENTS WITH MECHANICAL CONTRACTOR. C. "CONTROL TYPE"-PROVIDE CONTROL AND CONNECTIONS: • "INT" = CONTROLS ARE MANUFACTURED INTEGRAL TO THE EQUIPMENT (SELF-CONTAINED). • "CONT" = EQUIPMENT OPERATES CONTINUOUSLY (NO CONTROLS). FOR MOTORS WITHOUT INTERNAL OVERLOAD PROTECTION, PROVIDE SEPARATE OVERLOAD PROTECTION. • "DDC" = CONTROL SIGNAL FROM TEMPERATURE CONTROL SYSTEM PROVIDED BY MECHANICAL CONTRACTOR OR TEMPERATURE CONTROLS CONTRACTOR. D. "DISCONNECT BY": • "ELECTRICAL" = DISCONNECT IS FURNISHED BY ELECTRICAL CONTRACTOR. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT FURNISHED BY MECHANICAL CONTRACTOR. • "MANUFACTURER" = DISCONNECT IS FURNISHED BY EQUIPMENT MANUFACTURER. ELECTRICAL CONTRACTOR SHALL PROVIDE MOUNTING AND ADDITIONAL CONNECTIONS REQUIRED FOR LOOSE DISCONNECTS FURNISHED BY EQUIPMENT MANUFACTURER. E. "DISCONNECT TYPE"-PROVIDE DISCONNECT/RECEPTACLE AT EQUIPMENT LOCATION AND ASSOCIATED CONNECTION TO EQUIPMENT AND BRANCH CIRCUIT: • "NF" = NON-FUSED DISCONNECT. SIZE AND POLE QUANTITY AS INDICATED. 20/1 AND SMALLER SHALL BE TOGGLE SWITCH DISCONNECT. • "F" = FUSED DISCONNECT. SIZE AND POLE QUANTITY AS INDICATED. FUSE PER MANUFACTURER'S RECOMMENDATIONS. • "INT" = DISCONNECT IS MANUFACTURED INTEGRAL TO THE EQUIPMENT. • LOCATE DISCONNECT ADJACENT TO EQUIPMENT PER NEC -PROVIDE WITH STRUT MOUNTING AS REQUIRED. WHERE DISCONNECT SERVES OUTDOOR EQUIPMENT, PROVIDE AS NEMA-3R. • PROVIDE DISCONNECT WITH EQUIPMENT GROUND KIT. • WHERE FEEDER INDICATED UTILIZES A NEUTRAL, PROVIDE DISCONNECT WITH SOLID NEUTRAL KIT. • DISCONNECTS NOT SHOWN AS "F" OR "NF" SHALL BE NON-FUSED. F. "FEEDER": • PROVIDE CONDUCTORS AND RACEWAY AS INDICATED. TYPICAL FORMAT IS: (FEEDER TAG) (NOMINAL SIZE) CONDUCTORS AND RACEWAY REQUIRED. 7100 East Belleview Ave. Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS. PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW. www.specializedeng.com 2024 © COPYRIGHT SES PROJECT # Drawn Checked Date Scale Proj. Number Drawing Number KEYPLAN 4321 A B C D Number Date Issued For ASPEN VALLEY HOSPITAL NUC-MED CT 401 Castle Creek Rd, Aspen, CO 81611 Aspen Valley Hospital 3" 1 1 / 2 " 1" 3/ 4 " 1/ 2 " 3/ 8 " 1/ 4 " 1/ 8 " 1/ 1 6 " 3/ 1 6 " 3/ 3 2 " 23298 01/24/2024 1/8" = 1'-0" Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt 5/7/2024 12:08:45 PM 5/7/2024 12:08:45 PM Autodesk Docs://23289.00 - AVH Nuc Med CT/23298_AVH Nuc Med_CT_SES_2022.rvt E700 01/24/2024 23289 ELECTRICAL SCHEDULES KDD RJA © 2 0 2 1 T h e S / L / A / M C o l l a b o r a t i v e , I n c . LUMINAIRE SCHEDULE MARK DESCRIPTION SUBS MANUFACTURER CATALOG # (NOTE A) LAMP / NOMINAL LUMENS CCT MINIMUM CRI VOLTAGE INPUT WATTS MOUNTING REMARKS A1 2'X2' ARCHITECTURAL TROFFER WITH CENTER LENS Y CORELITE R3-WL-3L35-LD5-UNV-22-T1-STD LED / 3065 3500 85 277 V 26 RECESSED GRID C1 CHANNEL MOUNTED RIBBON LIGHT P NOVA NF-PRO-O-120-24V-3225K, 1707-WHT-SFT LED / 197 PER FT 3225 80 120 V 30 SURFACE CEILING 1 D1 4" DOWNLIGHT WITH SEMI-SPECULAR REFLECTOR AND MEDIUM WIDE DISTRIBUTION Y GOTHAM EVO4-35/20-AR-LSS-MWD-MVOLT-GZ1-TR W-90CRI LED / 2000 3500 90 277 V 20 RECESSED U1 24" UNDERCABINET TASK LIGHT WITH INTEGRAL ON/OFF SWITCH Y HALO HU11-21-D9-S-P LED / 785 3500 90 120 V 11 SURFACE X1 X-RAY IN USE WARNING LIGHT P DUAL LITE SESRW-SW4 LED -- 120 V 3 SURFACE WALL 2 LIGHTING CONTROL SEQUENCE OF OPERATIONS TAG SPACE TYPE OCCUPANCY SENSOR AUTO ON % AUTO OFF %NETWORK RECEPTACLE CONTROLTYPE TIME DELAY FA5 FINE MOTION - AUTO ON - 5 MINUTE DT-F 5 50 0 Y N PRO PROCEDURE - - - - Y N A. EXISTING PANEL. UPDATE PANEL DIRECTORY. GENERAL REMARKS: CIRCUIT BREAKER OPTIONS SUFFIX: 'S' OR 'ST' - PROVIDE SHUNT TRIP CIRCUIT BREAKER / 'G' OR 'GFCI' - PROVIDE GFCI CIRCUIT BREAKER / 'GFP' - PROVIDE GFP CIRCUIT BREAKER / 'ERMS' - ENERGY REDUCING MAINTENANCE SWITCH / 'L' - PROVIDE CIRCUIT BREAKER WITH LOCKING PROVISIONS / 'NEW' - PROVIDE NEW CIRCUIT BREAKER TO MATCH EXISTING MANUFACTURER, TYPE AND AIC RATING / 'REV' - NEW CIRCUIT TO EXISTING SPARE CIRCUIT BREAKER OPTIONS: 83 0 VA 0 VA 1 20 A -- SPARE 84 81 SPARE -- 20 A 2 0 VA 0 VA 1 20 A -- LTG - ADMIN 82 79 0 VA 0 VA 1 20 A -- LTG - ICU 80 77 SPARE -- 20 A 2 0 VA 0 VA 1 20 A -- LTG - NUC LAB 78 75 REC - IT -- 20 A 1 0 VA 0 VA 1 20 A -- INSTAHOT - CARDIAC 76 73 REC - IT CATV -- 20 A 1 0 VA 0 VA 1 20 A -- UC REFRIG - CARDIAC 74 71 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- MICROWAVE - CARDIAC 72 69 0 VA 0 VA 1 20 A -- COFFEE - CARDIAC 70 67 SPARE -- 30 A 2 0 VA 0 VA 1 20 A -- REC - CARDIAC BREAK 68 65 REC - NUC MED 20 A 1 720 VA 0 VA 1 20 A -- DISPOSAL - CARDIAC 66 63 REC - NM TECH 20 A 1 720 VA 0 VA 1 20 A -- SPARE 64 61 EF-21 NUC MED -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 62 59 LTG - NUC MED REV 20 A 1 60 VA 0 VA 1 20 A -- REC - CARDIAC HOT LAB 60 57 LTG - NUC MED IN USE REV 20 A 1 6 VA 0 VA 1 20 A -- REC - CARDIAC WAIT 58 55 REC - CARDIAC WORK TECH -- 20 A 1 0 VA 0 VA 1 20 A -- REC - CARDIAC BREAK, HALL 56 53 REC - CARDIAC DIAGNOSTICS -- 20 A 1 0 VA 0 VA 1 20 A -- REC - CARDIAC DIR OFF 54 51 REC - CARDIAC PFT -- 20 A 1 0 VA 0 VA 52 49 SPARE -- 20 A 1 0 VA 0 VA 50 47 INJECTOR - NUC MED REV 20 A 1 300 VA 0 VA 3 100 A -- PANEL L1D1 48 45 REC - CARDIAC EQUIP -- 20 A 1 0 VA 0 VA 1 20 A -- REC - STRESS TEST 46 43 REC - CARDIAC LKR, EQ, RR -- 20 A 1 0 VA 562 VA 1 20 A REC - NM TECH 44 41 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 42 39 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 40 37 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- REC - ROOF 38 35 REC - ICU OFFICE, CONF -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 36 33 REC - JAN, ANTE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 34 31 REC - ICU EQ, CLEAN -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 32 29 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- ICE MAKER - ICU 30 27 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- UC REFRIG - ICU 28 25 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- COFFEE - ICU 26 23 ICU BOOM BRAKE -- 20 A 1 0 VA 0 VA 1 20 A -- MICROWAVE - ICU 24 21 ICU BOOM BRAKE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 22 19 ICU BOOM BRAKE -- 20 A 1 0 VA 0 VA 1 20 A -- REC - ICU CLEAN 20 17 ICU BOOM BRAKE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 18 15 REC - ICU ISO ROOM BOOM -- 20 A 1 0 VA 0 VA 1 20 A -- REC - ICU N.S. PRINTER 16 13 REC - ICU ISO ROOM -- 20 A 1 0 VA 0 VA 1 20 A -- REC - ICU NURSE STATION 14 11 REC - ICU ISO ROOM BOOM -- 20 A 1 0 VA 0 VA 1 20 A -- REC - ICU NURSE STATION 12 9 REC - ICU ISO ROOM -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 10 7 REC - ICU ISO ROOM BOOM -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 8 5 REC - ICU ISO ROOM -- 20 A 1 0 VA 0 VA 1 20 A -- REC - QUIET ROOM 6 3 REC - ICU ISO ROOM BOOM -- 20 A 1 0 VA 0 VA 1 20 A -- REC - SOIL, CORR 4 1 REC - ICU ISO ROOM -- 20 A 1 0 VA 0 VA 1 20 A -- REC - STOR, RR, LKR, CTYD 2 CKT CIRCUIT DESCRIPTION OPT RATING POLES A B C POLES RATING OPT CIRCUIT DESCRIPTION CKT NEMA ENCLOSURE:1 MOUNTING:SURFACE AVAILABLE SCC (kA):10 PANEL POLES:84 SERVICE RATED:No INTEGRAL SPD:No SECTIONS:2 BRANCH:NORMAL WIRES:4 MCB OPTIONS: SUPPLY FROM:NSDH1B PHASES:3 MCB/MLO RATING:250 A LOCATION:ELECTRICAL 1650 VOLTS:208/120 WYE MAINS TYPE:MCB LIGHTING PANEL: L1D A. EXISTING DISTRIBUTION BOARD. UPDATE PANEL DIRECTORY. GENERAL REMARKS: CIRCUIT BREAKER OPTIONS SUFFIX: 'S' OR 'ST' - PROVIDE SHUNT TRIP CIRCUIT BREAKER / 'G' OR 'GFCI' - PROVIDE GFCI CIRCUIT BREAKER / 'GFP' - PROVIDE GFP CIRCUIT BREAKER / 'ERMS' - ENERGY REDUCING MAINTENANCE SWITCH / 'L' - PROVIDE CIRCUIT BREAKER WITH LOCKING PROVISIONS / 'NEW' - PROVIDE NEW CIRCUIT BREAKER TO MATCH EXISTING MANUFACTURER, TYPE AND AIC RATING / 'REV' - NEW CIRCUIT TO EXISTING SPARE CIRCUIT... OPTIONS: 16 PANEL H1A -- 3 150 A 0 VA 15 PANEL H2A -- 3 150 A 0 VA 14 SPARE -- 3 150 A 0 VA 13 PANEL H1F -- 3 200 A 0 VA 12 SPARE -- 1 20 A 0 VA 11 SPARE -- 1 20 A 0 VA 10 SPARE -- 1 20 A 0 VA 9 SPARE -- 1 20 A 0 VA 8 SPARE -- 1 20 A 0 VA 7 H-1 NUC MED NEW 3 35 A 21000 VA 6 NUC MED / CT NEW 3 90 A 45000 VA 5 PANEL L1D -- 3 110 A 0 VA 4 ELEVATOR (OFF) -- 3 70 A 0 VA 3 PH-6 (OFF) -- 3 50 A 0 VA 2 H-1 IT ROOM -- 3 30 A 0 VA 1 H-2 NUC MED REV 3 15 A 6000 VA CKT CIRCUIT DESCRIPTION OPT POLES RATING Load CIRCUIT REMARKS AVAILABLE SCC (kA):35 SERVICE RATED:No INTEGRAL SPD:No SECTIONS:1 BRANCH:NORMAL WIRES:4 MCB OPTIONS: SUPPLY FROM:MDS PHASES:3 MCB/MLO RATING:600 A LOCATION:ELECTRICAL 1650 VOLTS:480/277 WYE MAINS TYPE:MLO NSDH1B 1 05/07/2024 NM RFI 1 EQUIPMENT CONNECTION SCHEDULE MARK DESCRIPTION KW FLA MOCP VOLTS PHASE POLES LOAD [VA] CONTROL TYPE DISCONNECT BY DISCONNECT TYPE FEEDER PANEL CIRCUIT NUMBER H-1 HUMIDIFIER 21 27.1 35 480 3 3 21000 INT ELECTRICAL F - 60/3 (4) (40A) 3-#8 CU, #10 CU GND - 3/4"C. NSDH1B 7 H-2 HUMIDIFIER 6 7.2 15 480 3 3 6000 INT ELECTRICAL F - 30/3 (2) (20A) 3-#12 CU, #12 CU GND - 3/4"C. NSDH1B 1 1 1 1 11/08/2024