Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.285 Pfister Dr.0027-2021-BCHO (11)
The City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 08/12/2021 justinh SEE NOTES #1 PLANS SPECIAL INSPECTION REQUIRED: -Structural steel welding: Field & Shop -High strength bolting -Epoxy anchors -Intumescent paint -Spray applied fire resistive materials -Permanent micropiles Special inspection is required per 2015 IBC section 1704. Inspector to verify that copy of agreement for inspection program to be on the job site prior to performing any inspections. A copy of all Special Inspector field reports to be on the job site for inspectors' review if requested. Failure to comply may result in denial of inspection. 0027-2021-BCHO PFISTER 285 LLC 285 PFISTER DR 273511309027 1 MASTER PERMIT 0028-2020-BRES External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ x 0027-2021-BCHO 8/12/21 MASTER PERMIT 0028-2020-BRES 1100 SQFT TOTAL (860 NEW, 240 EXIST) ID-0.1.001 98% NONE JH SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ'S All snowmelt systems shall meet the following: - Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. - R10 insulation shall be installed under the area to be snowmelted or R5 insulation shall be installed under the slab edges. (Ordinance 11 Series 2011) - Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2015 IECC R403.9 and C403.2.4.5) - Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2015 IECC R403.9 and C403.2.3.5) - Inspection by testing hydrostatically at 1.5 times max system design pressure, but not less than 100psi, for 15 minutes. (2015 IMC 1208.1) VERSASHIELD®U NDERLAYMENT PRODUCT SPECIFICATIONS VERSASHIELD®CLASS A RATING LAYER R EQUIREMENTS WHEN INSTALLED IN ACCORDANCE WITH SECTION 2.4 OF ELK'S ICBO ES ER 5627, VERSASHIELD UNDERLAYMENT CAN BE USED AS AN ALTERNATIVE TO THE COVERING MATERIALS SPECIFIED IN SECTION 1516.3 OF THE UBC APPENDIX AND SECTION 1510.4 OF THE IBC OR SECTION R 907.4 OF THE IRC. SpecificationPrescriptive Requirements Performance Requirements Test Method Reference Performance Requirements VSB1000 Roll 100 ft. minimum 42 in., ±0.7% 350 sq. ft. minimum 52.5 lb. minimum 15 lb. per 100 sq. ft. min. Maximum of 25% Packaged: Linear Feet/roll Roll Width Area per roll Roll Weight Fabric Weight Loss on ignition MD CD 60 lbf minimum 30 lbf minimum ASTM D 146/D 828, 1" x 5" samples ASTM D 146/D 828, 1" x 5" samples MD CD Water Vapor Transmission permeance, perm Liquid water transmission test 400 grams minimum 550 grams minimum 3 minimum Pass D 1922, 2.5” x 3” samples D 1922, 2.5” x 3” samples E 96 D 4869 ASTM D 146 ASTM D 146 ASTM D 146 ASTM D 146 ASTM D 146 TAPPI T-1013 OM92 Average Breaking Strength @ 77 ±2 degree F. (Tensile Strength) Tear Strength @ 77 ±2 degree F Stone Coated Steel Steel Any Steel Any Steel Any Copper Any Copper Aluminum Material NOTE: VERSASHIELD IS AN APPROVED ALTERNATIVE TO #15 AND #30 FELT AS AN UNDERLAYMENT FOR ASPHALT SHINGLES. FOR LOW SLOPE APPLICATIONS, 2/12 OR 4/12, OR WHEREVER LOCAL CODES REQUIRE, USE TWO LAYERS. Direct to Deck Shingle Direct to Deck Shingle Batten Required Shingle Panel or Standing Seam Panel or Standing Seam Panel or Shingle Shingle Roof Type 0.013” 0.013” 0.013” 0.015” 0.016” 0.016” 0.018” Min. Thickness 1 Layer 1 Layer + 30 Felt 1 Layer 1 Layer 1 Layer 1 Layer + 30 Felt 2 Layers 15/32” Plywood N/A N/A 2 Layers N/A N/A 2 Layers N/A Existing Wood Shake/Shingle 1 Layer 1 Layer + 30 Felt 1 Layer 1 Layer 1 Layer 1 Layer + 30 Felt N/A Spaced Sheathing VERSASHIELD®CLASS B RATING LAYER R EQUIREMENTS Steel Any Steel Any Copper Any Aluminum Material Direct to Deck Shingle Batten Required Shingle Shingle Panel or Shingle Roof Type 0.013” 0.013” 0.016” 0.018” Min. Thickness 1 Layer N/A 1 Layer 1 Layer 15/32” Plywood N/A 1 Layer 1 Layer 1 Layer Existing Wood Shake/Shingle 1 Layer N/A 1 Layer 1 Layer Spaced Sheathing Ideal Application: Commercial Institutional Structural DMC 200S Profile The versatility of the DMC 200S roof system makes it an ideal choice for low to steep slope applications. Performance- engineered to handle heavy- duty commercial and industrial projects, this 2" mechanically seamed structural metal roof system will meet or exceed most windload and government requirements from coast to coast. Concealed fasteners and floating clip systems reduce panel stress from changes in temperature and help maintain a smooth, uniform appearance. This product can also be curved for large barrel roofs or small canopies. Weather Tightness Warranty Approved! Single lock panel Double lock panel 05/12/2021 05/12/2021 300 HT WATER & ICE PROTECTION HIGH-TEMPERATURE PROTECTION WIP 300HT High-Temperature Protection Self-Adhering Roofi ng Underlayment WIP 300HT is a high-tensile-strength rubberized asphalt underlayment specifi cally designed to withstand temperatures up to 250°F (121°C ). Ideal for use under metal including copper, zinc and COR-TEN® (consult technical department for installation instructions), WIP 300HT can also be used under synthetic, concrete and c lay tiles and asphalt shingles. This strong, skid-resistant membrane is available in either black or white and provides superior protection from water penetration caused by wind-driven rain and ice dams. Features and Benefi ts • Protects the roof structure from water seepage caused by ice dams and wind-driven rains • Resists temperatures up to 250°F without degradation of the adhesive • Seals around roofi ng nails, staples and screws • Split-release fi lm provides easier, faster installation • Resists cracking, drying and rotting, providing long-term waterproofi ng performance and low lifecycle cost • Concealed waterproofi ng system will not detract from the architectural aesthetics of the primary roofi ng system • Exposed rubberized asphalt bead along the membrane edge ensures watertightness of lap seams • 180 days exposure time Standards • UL Classifi ed • ICC-ES ESR #2206 • 2009 and 2012 International Building Code™ • 2007 Florida Building Code Approved Product #6785 • Meets ASTM D1970 • Miami-Dade County Product Control Approved Storage WIP 300HT roofi ng underlayment rolls should be stored on their side, under cover and in areas where the temperature is between 40° and 100°F (4.4° and 38°C). Do not double-stack pallets. Warranty Carlisle WIP products are backed by Carlisle’s industry-leading warranty. Carlisle WIP Products will display optimal performance when stored under recommended conditions and used within one year of date of manufacture. Product installed af ter one year of date of manufacture is not covered under defect warranty. Visit our website for warranty details. Installation WIP 300HT underlayment is applied when the roof deck is dry and the substrate temperature is 40°F (4.4°C) or higher. At temperatures below 40°F, nailing or priming should be used to temporarily hold the membrane in place while adhesion develops. WIP 300HT is designed to be covered with the primary roofi ng system and should not be exposed to sunlight for more than 60 days (black fi lm only). White underlayment offers exposure time of 180 days. Substrate must be free of any moisture. If moisture is present, it may inhibit adhesion.Prepare the roof deck by removing all loose objects, dirt, dust and debris.For re-roofi ng applications, remove all old materials from the roof deck in the area to be covered with WIP 300HT underlayment. Replace water-damaged sheathing and sweep roof deck thoroughly. 05/12/2021 08/12/2021 justinh SEE NOTES #1 PLANS Installation: Can be installed over open frame steel purlins, steel decking, steel decking with PolyIso or plywood decking. Factory made or field rolled to exact lengths Optional: striation, beads, pencil ribs Available: Radius panel (single or double lock) Slope: Minimum slope 1/2:12 Production options: Aluminum Substrate: High-performance painted metal roofing product, carefully tensioned leveled for superior flatness. 35 35-Year Non Pro-rated PVDF Paint Warranty YEAR WARRANTY Galvalume® Substrate: High-performance painted metal roofing product, carefully tensioned leveled for superior flatness. 35 35-Year Non Pro-rated PVDF Paint Warranty YEAR WARRANTY Drexlume® Substrate: Mill finished Galvalume® with a two-sided, clear acrylic finish. 25 25-Year Non Pro-rated Drexlume Warranty (Acrylic Coated Galvalume) YEAR WARRANTY Finishes and product warranty: Available in a variety of coatings and colors by AkzoNobel. See the Drexel Metals color card for standard colors and paint specifications. Minimum Roof Pitch: 1/2:12 – low roof pitch • UL 580 Wind Uplift (Class 90) • TAS 125 Wind Uplift • UL 1897 Extended Phase Wind Uplift • UL 2218 Class 4 Hail Impact • UL 790 Class A Fire Rating • UL Environmental – SRI Third Party Verified • ASTM E1592 Uniform Static Air Pressure Uplift • ASTM E1646 Water Infiltration • TAS 100 Wind Driven Rain • ASTM E1680 Air Infiltration • ASTM E1886 Missile Impact • ASTM 2140 Static Pressure Water Head • Miami-Dade County Approved • Florida Building Code Approved • Texas Department of Insurance Approval Testing: In accordance with: DMC 200S Profile 1234 Gardiner Lane, Louisville, KY 40213 888-321-9630 toll-free • 502-690-6174 fax ©2013 Drexel Metals, Inc. All rights reserved. Galvalume® is a registered trademark of BEIC International, Inc. Drexlume™ is a trademark of Drexel Metals, Inc. ENERGY STAR name and logo are registered U.S. marks and are owned by the U.S. government. Colors shown represent the actual color as closely as possible. To ensure exact color for final approval, a metal color chip is available. Warranty statements mentioned are outlines: complete Limited Warranty information is available on request. No other warranty expressed or implied is applicable. Available widths: 12", 14", 16" or 18"* Substrates available: • Galvalume® – 22ga and 24ga • Drexlume® – 22ga and 24ga • Aluminum – .040" w w w . d r e x e l m e t a l s . c o m *Drexel Metals design pressures, wind uplifts and test reports are for specific deck attachments, material gauges, clip spacing and panel widths. A complete specification and listing is available online at www.drexelmetals.com Allowable uniform: Inward load table – psf 2.00 2.50 3.00 3.50 4.00 5.00 5.00 251 201 145 108 83 66 53 Outward load table – psf Span 24 ga x 16" 2.00 2.50 3.00 3.50 4.00 5.00 5.00 106 95 83 72 60 49 37 Deflection Ratio L/180 Span 24 ga x 16" 05/12/2021 05/29/2020 05/12/2021 0027-2021-BCHO 05/29/2020 05/12/2021 05/29/2020 05/12/2021 0027-2021-BCHO DAM Denis Murray 5/29/20 denis.murray@cityofaspen.com 05/29/2020 DAM Denis Murray 5/29/20 denis.murray@cityofaspen.com 05/12/2021