Loading...
HomeMy WebLinkAboutFile Documents.1265 Mountain View Dr.0033-2020-BRES (15)PLATEPRODNAMEPRODCLASSMATERIALKPGRIPGUSER1USER2USER3 BEDROOM #3 004 SHARED BATH 003 BEDROOM #2 002 CRAWL SPACE 005 BEDROOM #4 104 BEDROOM #5 008 MECHANICAL 006 SHARED BATH #2 007 BEDROOM #6 009 HALLWAY 001 RELOCATE ELEC PANEL EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING BATH #3 008 EXISTING LAUNDRY 005 REMOVE EXISTING WALLS AND DOOR REMOVE EXISTING WALLS AND DOOR REMOVE EXISTING WALLS CABS AND FIXTURES REPLACE WINDOW PER NEW PLAN REPLACE WINDOW PER NEW PLAN REPLACE WINDOW PER NEW PLAN REPLACE WINDOW PER NEW PLAN REPLACE WINDOW PER NEW PLAN REPLACE WINDOW PER NEW PLAN RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N REMOVE EXISTING WALLS AND DOOR REMOVE EXISTING WALLS AND DOOR REMOVE EXISTING WALLS AND DOOR REMOVE EXISTING WALLS AND DOOR SCALE: SHEET NO. wmr AS P E N , C O L O R A D O 12 6 5 M O U N T A I N V I E W D R I V E PR I V A T E R E S I D E N C E CO DETECTORS TO BE INSTALLED PER CURRENT CODE DATE REVISION TITLE : C ALL RIGHTS, IDEAS, ARRANGEMENTS AND PLANS INDICATED IN THESE DRAWINGS ARE THE PROPERTY OF HANCOX GROUP INC. AND SHALL NOT BE USED BY ANY OTHER PERSON FOR ANY USE WITHOUT WRITTEN PERMISSION. COPYRIGHT, 2020 ALL RIGHTS RESERVED PLAN NORTH 10-4-19 CONCEPT HA N C O X gr o u p ar c h i t e c t u r e a n d p l a n n i n g 31 4 s o p r i s c i r c l e ba s a l t , c o l o r a d o 8 1 6 2 1 97 0 - 6 1 8 - 5 5 8 8 IN F O @ H A N C O X G R O U P . C O M TOPO. 7,901.5' = ARCH. 100'-0" 03-02-20 BLDG. DEPT SUBMITTAL 03-28-20 BLDG. DEPT SUBMITTAL REVISED A2.01 1/4" = 1'-0" LOWER LEVEL EXISTING/DEMO FLOOR PLAN 03/31/2020 7,003 sf 2,389.33 sf 1,658.46 sf 4,369.79 sf 2,179.95 sf total 7,003+4370 = Remodel 2390+1659+2180= PLATEPRODNAMEPRODCLASSMATERIALKPGRIPGUSER1USER2USER3 PLATEPRODNAMEPRODCLASSMATERIALKPGRIPGUSER1USER2USER3 FAMILY ROOM 105 LIVING AREA 104 MASTER BEDRM. 110 OFFICE 102 MASTER BATH 112 WALK-IN 111 BEDROOM #1 107 BATH #1 108 PWDR 106 MUDROOM #2 114 MUDROOM 113 ENTRY PORCH 116 GARAGE 115 KITCHEN 103 ENTRY FOYER 101 CLOSET 109 EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING REMOVE EXISTING WALLS AND DOOR REMOVE EXISTING WALLS CABINETS AND APPLIANCES REMOVE EXISTING WALLS AND DOOR REMOVE EXISTING WALLS AND DOOR REMOVE EXISTING WALLS CABS AND FIXTURES REMOVE EXISTING WALLS AND DOOR REMOVE EXISTING WALLS CABS AND FIXTURES REMOVE EXISTING STAIRS AND LANDING REMOVE EXISTING HALF WALL AND RAILINGS REMOVE EXISTING DOORS AND PREP FOR NEW DOOR REMOVE EXISTING FIREPLACE REMOVE EXISTING DOORS AND PREP FOR NEW DOOR REPLACE WINDOW PER NEW PLAN REPLACE WINDOW PER NEW PLAN REPLACE WINDOW PER NEW PLAN REPLACE WINDOW PER NEW PLAN RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N RE P L A C E W I N D O W PE R N E W P L A N REMOVE EXISTING DECK AND STAIRS REMOVE EXISTING DOORS AND PREP FOR NEW DOOR REPLACE WINDOW PER NEW PLAN REPLACE WINDOW PER NEW PLAN REPLACE WINDOW PER NEW PLAN REMOVE EXISTING ENTRY PORCH SEE PROPOSED FOR LIMITS TO DEMO REMOVE EXISTING STEPS AND LANDING REMOVE EXISTING WALLS CABS AND FIXTURES SHORE EXISTING BEAM UNTIL MODIFICATIONS ARE MADE SCALE: SHEET NO. wmr AS P E N , C O L O R A D O 12 6 5 M O U N T A I N V I E W D R I V E PR I V A T E R E S I D E N C E CO DETECTORS TO BE INSTALLED PER CURRENT CODE DATE REVISION TITLE : C ALL RIGHTS, IDEAS, ARRANGEMENTS AND PLANS INDICATED IN THESE DRAWINGS ARE THE PROPERTY OF HANCOX GROUP INC. AND SHALL NOT BE USED BY ANY OTHER PERSON FOR ANY USE WITHOUT WRITTEN PERMISSION. COPYRIGHT, 2020 ALL RIGHTS RESERVED PLAN NORTH 10-4-19 CONCEPT HA N C O X gr o u p ar c h i t e c t u r e a n d p l a n n i n g 31 4 s o p r i s c i r c l e ba s a l t , c o l o r a d o 8 1 6 2 1 97 0 - 6 1 8 - 5 5 8 8 IN F O @ H A N C O X G R O U P . C O M TOPO. 7,901.5' = ARCH. 100'-0" 03-02-20 BLDG. DEPT SUBMITTAL 03-28-20 BLDG. DEPT SUBMITTAL REVISED A2.02 3/16=1'-0" MAIN LEVEL EXISTING/DEMO FLOOR PLAN 03/31/2020 0 sf 22,270.7 sf Total 22,270 Remodel 3477 3,476.8 sf Downstairs and Upstairs. Total: 7,003+4370+22270 = 33643 Remodel: 2360+1659+2180+3477= 9676 9676/33643=29% I know the area is not calibrated correctly. I just need percentages so it doesn't matter. CRAWL SPACE 015 BEDROOM #4 010 MECHANICAL 009 BEDROOM #5 012 BATH #5 013 LOWER HALLWAY 014 BATH #4 011 BEDROOM #2 004 BATH #2 005 REC. ROOM 001 I.T. 006 hallway 00214 ' - 1 1 1 2" 13'-5" 4'-0" 4'-5" 15'-11" 11 ' - 9 " 12 ' - 1 1 " 15'-0" 2' - 3 1 2" 7'-21 2" 2'-9" 6'-3" 4' - 9 1 2" 6' - 5 " 6' - 5 " 4'-01 2"10'-111 2" 6'-6" 01 02 03 04 06 07 08 09 10 11 12 13 1415 005 A 004 A 006 A 004 B 013 A 012 B 012 A 009 A 011 A 010 A 010 B 010 C 05 4'-6"7'-6"7'-6"4'-6" 8' - 2 " 24'-0" 14 ' - 2 " 19 ' - 1 1 1 2" 6' - 9 " 8' - 6 " 2' - 4 1 2" 6' - 9 " 9'-0" 2' - 2 1 2" 8' - 3 " 4' - 1 1 1 2" 5' - 0 " 9' - 3 1 2" 2' - 3 1 2" 32 ' - 0 " BEDROOM #3 007 101 007 008 A SINKUC REF MICRO B-IN MU R P H Y / L E D 6'-0"7'-5" 16'-101 2" 4' - 0 1 2" LAUNDRY 003 SI N K W/ D DR Y I N G 14'-2"3'-6" EL E C P A N E L UP SH SH SH 5'-0" 7' - 9 1 2" 4' - 7 " 3' - 6 " 10 ' - 0 " 8" 6" 8' - 8 1 2" 912" BATH #3 008 3'-6"2'-51 2" FUR ALL LOWER WALLS OUT TO FACE OF FOUNDATION (TYP) FUR ALL LOWER WALLS OUT TO FACE OF FOUNDATION (TYP) 1 A4.1 1 A4.1 SD SD SD SD SD SD plan notes: All new lighting will be 75% high efficacy SCALE: SHEET NO. wmr AS P E N , C O L O R A D O 12 6 5 M O U N T A I N V I E W D R I V E PR I V A T E R E S I D E N C E CO DETECTORS TO BE INSTALLED PER CURRENT CODE DATE REVISION TITLE : C ALL RIGHTS, IDEAS, ARRANGEMENTS AND PLANS INDICATED IN THESE DRAWINGS ARE THE PROPERTY OF HANCOX GROUP INC. AND SHALL NOT BE USED BY ANY OTHER PERSON FOR ANY USE WITHOUT WRITTEN PERMISSION. COPYRIGHT, 2020 ALL RIGHTS RESERVED PLAN NORTH 10-4-19 CONCEPT HA N C O X gr o u p ar c h i t e c t u r e a n d p l a n n i n g 31 4 s o p r i s c i r c l e ba s a l t , c o l o r a d o 8 1 6 2 1 97 0 - 6 1 8 - 5 5 8 8 IN F O @ H A N C O X G R O U P . C O M TOPO. 7,901.5' = ARCH. 100'-0" 03-02-20 BLDG. DEPT SUBMITTAL 03-28-20 BLDG. DEPT SUBMITTAL REVISED A2.03 1/4" = 1'-0" LOWER LEVEL FLOOR PLAN 03/31/2020 K-5714-GUNDERSCOREBATHACRYLIC BEDROOM #1 111 BATH #1 112 ENTRY PORCH 116 ENTRY FOYER 101 GARAGE 107 KITCHEN 104 MUDROOM 105 DINING AREA 108 MASTER BED 114 WALK-IN 117 MASTER ANTE 113 MASTER BATH 115 W.C. 116 PWDR 103 NEW DECK AREA 017FAMILY ROOM 110 LIVING AREA 109 BAR 102 WALK-IN DW SINK RE F / F R Z SEAT S.H. S.H. SINK WALK-IN BENCH UP DN RA N G E UC REF DW PA N T R Y 3'-21 2"3'-0"3'-21 2" 4' - 1 1 2" 6' - 0 " 3' - 6 " SI N K UC R E F DN UP BU I L T - I N BU I L T - I N NEW STAIR LOCATIONS WOOD FINISH MATCH EXISTING RISE AND RUN CABLE RAIL SYSTEM WITH WOOD HANDRAIL TYPICAL TO CODE NEW STEPS 2 R @ 6". 1 T @12" NEW BAR AREA TILE TILE TILE WOOD TILE WOOD WOOD WOOD CARPET CARPET TILE W T W T WOOD C W C W TILE TILE TILE STAINED CONCRETE STAINED CONCRETE C W C T TILE COATS EXISTING CONCRETE WINE OPTIONAL ISLAND OR FARM TABLE 31 ' - 8 " 11 ' - 7 1 2" v e r i f y 17'-1" 7'-0" 7' - 6 1 2" 3' - 8 " 2' - 5 1 2" 6'-101 2"7' - 6 1 2" 22'-01 2" 12 ' - 1 0 3 4" 3' - 6 " 3' - 8 " 31'-6" 17 ' - 0 1 2" HEAT N GLO FDN -5 -SS GAS FIREPLACE 8'-6"7'-0"8'-6" 3' - 0 " 5'-51 2"12'-0"5'-01 2" 1' - 0 " 4'-51 2"9'-01 2" 5' - 4 " 8" 8" 8" 8' - 0 " 6"8"8"8"14'-9"8"8"8" 8' - 6 " 7'-4"19'-9" 101 A 16 TRANSOM 1718 19 20 21 22 23 24 25 26 27 28 29 32 33 34 35 36 37 38 394041 101 B 103 A 101 A 111 A 111 B 112 A 101 A 106 A 115 A 116 A 113 A 114 A 108 A 107 A 3' - 2 " 6" STEP NEED TO VERIFY MIN. HEAD HT AT STAIR TO ALLOW FOR NEW BUNK (S) 8' - 2 1 2" 17 ' - 7 " 8' - 1 0 " 1' - 7 " 4' - 8 1 2" 5' - 3 1 2" 3' - 6 " 4'-51 2"15'-1"4'-51 2" 8' - 0 " 6"6" 15'-9" 6'-0" 8' - 2 " 11 ' - 1 1 1 2" 6' - 1 1 1 2" 4' - 1 1 " 4'-61 4"4'-11 2"7'-31 2"4'-11"3'-01 2"6'-10" 5'-91 2"5'-9" 5'-3"6'-31 2" 2'-71 2"3'-0" 4" 3' - 5 " 6' - 0 " 3' - 5 " 3'-0" 4' - 3 1 4" 30 TRANSOM 31 TRANSOM 5' - 9 " 3'-9" 8" CABLE RAIL SYSTEM WITH WOOD HANDRAIL TYPICAL TO CODE UP (2 ) 1 4 " T (3 ) 6" R EXISTING STAIRS TO REMAIN HEAT N GLO FDN -5 -SS GAS FIREPLACE BACK ENTRY 106 1 A4.1 1 A4.1 EXTERIOR DOWN LITE EXTERIOR DOWN LITE EXTERIOR DOWN LITE EXTERIOR DOWN LITE EXTERIOR DOWN LITE EXTERIOR DOWN LITE EXTERIOR DOWN LITE SD SD SD SD SD plan notes: All new lighting will be 75% high efficacy SCALE: SHEET NO. wmr AS P E N , C O L O R A D O 12 6 5 M O U N T A I N V I E W D R I V E PR I V A T E R E S I D E N C E CO DETECTORS TO BE INSTALLED PER CURRENT CODE DATE REVISION TITLE : C ALL RIGHTS, IDEAS, ARRANGEMENTS AND PLANS INDICATED IN THESE DRAWINGS ARE THE PROPERTY OF HANCOX GROUP INC. AND SHALL NOT BE USED BY ANY OTHER PERSON FOR ANY USE WITHOUT WRITTEN PERMISSION. COPYRIGHT, 2020 ALL RIGHTS RESERVED PLAN NORTH 10-4-19 CONCEPT HA N C O X gr o u p ar c h i t e c t u r e a n d p l a n n i n g 31 4 s o p r i s c i r c l e ba s a l t , c o l o r a d o 8 1 6 2 1 97 0 - 6 1 8 - 5 5 8 8 IN F O @ H A N C O X G R O U P . C O M TOPO. 7,901.5' = ARCH. 100'-0" 03-02-20 BLDG. DEPT SUBMITTAL 03-28-20 BLDG. DEPT SUBMITTAL REVISED A2.04 1/4"=1'-0" MAIN LEVEL FLOOR PLAN EXTERIOR LIGHTING NOTE: ALL EXTERIOR LIGHTING SHALL COMPLY WITH THE ASPEN LIGHTING CODE. ALL LIGHTS WILL BE DOWN LIT AND THE SOURCE OF LIGHT SHALL BE SHIELDED. SEE ATTACHED CUT SHEET FOR LIGHT. 03/31/2020