Loading...
HomeMy WebLinkAboutFile Documents.134 E Bleeker St.0102-2020-BRES (49)8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 EE CC B B AA D D SETBACK SETBACK PR O P E R T Y L I N E PROPERTY LINE PROPERTY LINE F F SLOPE 13 1/2" : 12" SLOPE 10 1/2" : 12" SL O P E 13 1 / 2 " : 1 2 " SL O P E 13 1 / 2 " : 1 2 " SLOPE 13 1/2" : 12" SLOPE 10 1/2" : 12" SL O P E 13 1 / 2 " : 1 2 " SL O P E 13 1 / 2 " : 1 2 " SLOPE 13 1/2" : 12" SL O P E 3 1 / 2 " : 1 2 " SLOPE 13 1/2" : 12" SLOPE 13 1/2" : 12" SL O P E 13 1 / 2 " : 1 2 " SL O P E 13 1 / 2 " : 1 2 " SL O P E 13 1 / 2 " : 1 2 " SL O P E 13 1 / 2 " : 1 2 " SLOPE 13 1/2" : 12" SL O P E 12 " : 1 2 " SLOPE 12" : 12" SLOPE 12" : 12" SLOPE 4" : 12" SL O P E 12 " : 1 2 " SL O P E 12 " : 1 2 " SL O P E 13 1 / 2 " : 1 2 " SL O P E 13 1 / 2 " : 1 2 " 1 A.4.01 2 A.4.01 1 A.4.02 2 A.4.02 PR O P E R T Y L I N E SETBACK PROPERTY LINE SE T B A C K EXISTING PLUMBING FLUE VENT; TO BE USED HISTORIC CHIMNEY TO REMAIN; TO BE USED AS PLUMBING VENT EXISTING PENETRATION; TO BE USED FOR 6" ROUND PLUMBING VENT HISTORIC PENETRATION; NOT IN USE HISTORIC PENETRATION; NOT IN USE EXISTING PENETRATION; TO BE USED FOR 8" ROUND PLUMBING VENT HISTORIC PENETRATION; NOT IN USE EXISTING CHIMNEY TO BE USED FOR 6" VENT R1 R1 R1 R1 R1 PROPOSED SNOW CLIPS TO BE PLACED PER MANUFACTURER SPECIFICATIONS ROOF SHINGLES TO BE REPLACED PER ROOF ASSEMBLY TYPE TO MATCH AESTHETIC CHARACTER OF EXISTING STRUCTURE CURRENT RIDGE FLASHING APPEARS TO BE NON-HISTORIC; FULL REPLACEMENT IS PROPOSED ON ALL ROOFS FLASHING AND GUTTERS TO BE UPDATED NOTES: 1. ALL EXISTING DIMENSIONS TO BE VERIFIED IN FIELD BY CONTRACTOR 2. REFER TO CIVIL PLANS FOR ALL DRAIN LOCATIONS 3. SNOW CLIPS PROVIDED ON ROOFS IN ORDER TO PREVENT SHEDDING OF ICE AND SNOW ONTO ADJACENT PROPERTIES, POTENTIALLY OCCUPIED AREAS, AND VEHICULAR ACCESS PER SECTION R910 EXISTING PENETRATION TO BE USED FOR 8" EXHAUST PT-01 PT-02 W53 W54 W52 3' - 0 1 / 8 " 2' - 0 1 / 2 " 2' - 0 1 / 2 " (E) SKYLIGHT TO REMAIN, REPLACE GLASS AS NEEDED WITH .06" PVB LAMINATED GLASS PER SKYLIGHT SPEC 1A 1A 1B 1B 4B 4B 11 1/2" 6' - 4 7 / 8 " R1 SL O P E 12 " : 1 2 " SL O P E 12 " : 1 2 " SL O P E 12 " : 1 2 " SL O P E 12 " : 1 2 " SLOPE 12" : 12" SLOPE 12" : 12" SLOPE 4" : 12" SLOPE 4" : 12" WALKWAY WALKWAY GRAVEL WALKWAY WALKWAY DR I V E W A Y BALCONY BALCONY WALKWAY SIDEWALK 1 A.4.03 1 A.4.06 Th e s e d o c u m e n t s a r e t h e p r o p e r t y o f EA D . A n y u n a u t h o r i z e d u s e w i t h o u t t h e wr i t t e n c o n s e n t o f E A D i s p r o h i b i t e d b y la w . E A D d i s c l a i m s r e s p o n s i b i l i t y f o r th e s e d o c u m e n t s i f t h e y a r e u s e d w h o l e or i n p a r t a t a n y o t h e r l o c a t i o n a n d f o r an y o t h e r a p p l i c a t i o n o t h e r t h a n t h e or i g i n a l i n t e n t . I f y o u a r e n o t t h e in t e n d e d r e c i p i e n t , y o u a r e h e r e b y no t i f i e d t h a t a n y d i s s e m i n a t i o n , di s t r i b u t i o n o r r e p r o d u c t i o n o f t h e s e do c u m e n t s i s p r o h i b i t e d b y l a w . 350 MARKET STREET SUITE 309 BASALT, COLORADO 81621 PHONE: 970.300.3423 FAX: 415.358.5771 INFO@EIGELBERGER.COM N Co p y r i g h t c 2 0 1 8 b y E I G E L B E R G E R A R C H I T E C T U R E & D E S I GN SCALE: Plot Date Drawn By Checked By Project No. CLIENT REVIEW: REVIEWED AND APPROVED FOR DESIGN INTENT: CLIENT UNDERSTANDS THE DESIGN INTENT OF THE DOCUMENT. CLIENT APPROVES DESIGN INTENT. ARCHITECT WILL PROCEED WITH DETAILS AND COORDINATION WITH CONTRACTOR PER SIGN OFF ON DOCUMENT. NOTE: ANY CHANGES TO THE APPROVED DRAWINGS BY CLIENT ARE ADDITIONAL SERVICE PER CONTRACT. ARCHITECT TO PICKUP CORRETIONS AS NOTED CLIENT SIGNATURE: ___________________________ DATE OF APPROVAL: __________________________ Date Issue 1/4" = 1'-0" BI M 3 6 0 : / / 1 9 0 1 7 - 1 3 4 B l e e k e r / 1 9 0 1 7 _ 1 3 4 E B l e e k e r S t _C E N T R A L . r v t 5/11/2021 1:40:12 PM A.2.10 (P) ROOF PLAN 13 4 E A S T B L E E K E R AS P E N , C O 19017 HANNAH-HUNT MOELLER Checker SCALE : 1/4" = 1'-0"A.2.10 1 (P) ROOF PLAN 8/12/2020 PERMIT Date 3 PERMIT COMMENT REV. 1 2 ARCHITECTURAL ASPHALT SHINGLES FOR ALL ROOFS, TYPICAL Staff & Monitor approve the request to change the roofing material to a dark colored architectural shingle on the historic resource and non-historic structure. The flashing material will be galvanized and the snow clips on the historic resource will be lead-coated copper. Date: 05/17/2021 Technical Data Sheet Landmark®, Landmark® Premium, Landmark® Pro Shingles, Landmark® Pro/Architect 80 (NW Region Only) Shingles PRODUCT INFORMATION Landmark shingles reflect the same high manufacturing standards and superior warranty protection as the rest of CertainTeed's line of roofing products. Landmark Premium (and Algae Resistant-AR), Landmark PRO (and AR) and Landmark (and AR) are built with the industry's toughest fiber glass mat base, and their strict dimensional tolerance assures consistency. Complex granule color blends and subtle shadow lines produce a distinctive color selection. Landmark is produced with the unique NailTrak nailing feature. Please see the installation instruction section below for important information regarding NailTrak. In the Northwest Region Landmark PRO (AR) is double-branded as Landmark PRO/Architect 80 (AR). Landmark algae-resistant (AR) shingles are algae-resistant and help protect against dark or black discoloration, sometimes called staining or streaking, caused by blue-green algae. AR shingles are not available in all regions. Colors: Please refer to the product brochure or CertainTeed website for the colors available in your region. Limitations: Use on roofs with slopes greater than 2" per foot. Low-slope applications (2:12 to < 4:12) require additional underlayment. In areas where icing along eaves can cause the back-up of water, apply CertainTeed WinterGuard Waterproofing Shingle Underlayment, or its equivalent, according to application instructions provided with the product and on the shingle package. Product Composition: Landmark Series shingles are composed of a fiber glass mat base. Ceramic- coated mineral granules are tightly embedded in carefully refined, water-resistant asphalt. Two pieces of the shingle are firmly laminated together in a special, tough asphaltic cement. All Landmark shingles have self-sealing adhesive strips. Applicable Standards ASTM D3018 Type I ASTM D3462 ASTM E108 Class A Fire Resistance ASTM D3161 Class F Wind Resistance ASTM D7158 Class H Wind Resistance UL 790 Class A Fire Resistance ICC-ES ESR-1389 and ESR-3537 CSA Standard A123.5 (Regional) Miami-Dade Product Control Approved Florida Product Approval # FL5444 Meets TDI Windstorm Requirements Technical Data: Landmark Landmark PRO* Landmark Premium (and AR) (and AR) (and AR) Weight/Square (approx.) 219 to 238 lb ** 240 to 267 lb ** 300 lb Dimensions (overall) 13 1/4" x 38 3/4" 13 1/4" x 38 3/4" 13 1/4" x 38 3/4" Shingles/Square (approx.) 66 66 66 Weather Exposure 5 5/8" 5 5/8" 5 5/8" *Includes Landmark PRO AR/Architect 80 **Dependent on manufacturing location Technical Data Sheet Landmark® Series Shingles Page 2 of 2 INSTALLATION Detailed installation instructions are supplied on each bundle of Landmark shingles and must be followed. Separate application sheets may also be obtained from CertainTeed. Hips and Ridges: For capping hip and ridge apply CertainTeed Shadow Ridge, Cedar Crest or Mountain Ridge shingles of a like color. MAINTENANCE These shingles do not require maintenance when installed according to manufacturer's application instructions. However, to protect the investment, any roof should be routinely inspected at least once a year. Older roofs should be looked at more frequently. WARRANTY Landmark Premium (and AR), Landmark PRO/Architect 80 AR, Landmark PRO (and AR), and Landmark (and AR) shingles carry a lifetime limited, transferable warranty to the consumer against manufacturing defects when applied to stated CertainTeed application instructions for this product. In addition, Landmark Premium (and AR), Landmark PRO (and AR), Landmark PRO/Architect 80 AR, and Landmark (and AR) carry 10-years of SureStart™ Protection. Landmark AR shingles carry a 10-year algae resistance warranty. Landmark Premium AR, Landmark PRO AR, and Landmark PRO/Architect 80 AR shingles carry a 15-year algae resistance warranty. For specific warranty details and limitations, refer to the warranty itself (available from the local supplier, roofing contractor or on-line at www.certainteed.com). FOR MORE INFORMATION Sales Support Group: 800-233-8990 Web site: www.certainteed.com See us at our on-line specification writing tool, CertaSpec®, at www.certainteed.com/certaspec. CertainTeed 20 Moores Road Malvern, PA 19355 © 01/20 CertainTeed Th e s e d o c u m e n t s a r e t h e p r o p e r t y o f EA D . A n y u n a u t h o r i z e d u s e w i t h o u t t h e wr i t t e n c o n s e n t o f E A D i s p r o h i b i t e d b y la w . E A D d i s c l a i m s r e s p o n s i b i l i t y f o r th e s e d o c u m e n t s i f t h e y a r e u s e d w h o l e or i n p a r t a t a n y o t h e r l o c a t i o n a n d f o r an y o t h e r a p p l i c a t i o n o t h e r t h a n t h e or i g i n a l i n t e n t . I f y o u a r e n o t t h e in t e n d e d r e c i p i e n t , y o u a r e h e r e b y no t i f i e d t h a t a n y d i s s e m i n a t i o n , di s t r i b u t i o n o r r e p r o d u c t i o n o f t h e s e do c u m e n t s i s p r o h i b i t e d b y l a w . 350 MARKET STREET SUITE 309 BASALT, COLORADO 81621 PHONE: 970.300.3423 FAX: 415.358.5771 INFO@EIGELBERGER.COM Co p y r i g h t c 2 0 1 8 b y E I G E L B E R G E R A R C H I T E C T U R E & D E S I G N SCALE: Plot Date Drawn By Checked By Project No. CLIENT REVIEW: REVIEWED AND APPROVED FOR DESIGN INTENT: CLIENT UNDERSTANDS THE DESIGN INTENT OF THE DOCUMENT. CLIENT APPROVES DESIGN INTENT. ARCHITECT WILL PROCEED WITH DETAILS AND COORDINATION WITH CONTRACTOR PER SIGN OFF ON DOCUMENT. NOTE: ANY CHANGES TO THE APPROVED DRAWINGS BY CLIENT ARE ADDITIONAL SERVICE PER CONTRACT. ARCHITECT TO PICKUP CORRETIONS AS NOTED CLIENT SIGNATURE: ___________________________ DATE OF APPROVAL: __________________________ Date Issue BI M 3 6 0 : / / 1 9 0 1 7 - 1 3 4 B l e e k e r / 1 9 0 1 7 _ 1 3 4 E B l e e k e r S t _ C E N T R A L . r v t 5/11/2021 1:37:59 PM A.7.05 MATERIALS 13 4 E A S T B L E E K E R AS P E N , C O 19017 HANNAH-HUNT MOELLER Checker GUTTERS, FLASHING, DOWNSPOUTS, AND SNOW STOPS 8/12/2020 PERMIT Date 3 PERMIT COMMENT REV. 1 ROOF SHINGLE ORIGNIAL EXTERIOR LIGHTING FIXTURE EXTERIOR LIGHTING FIXTURE EL-01 EXTERIOR LIGHTING FIXTURE EL-02 2 ARCHITECTURAL ROOF SHINGLE CERTAINTEED LANDMARK, OR EQUAL COLOR: WEATHERED WOOD SEQUENCE OF INSTALLATION FOR SELF ADHERING FLASHING (S.A.F.) 1. LAP S.A.F. OVER BLDG. PAPER AT SILL 2. INSTALL JAMB S.A.F. -LAP OVER SILL S.A.F. 3. INSTALL WINDOW WITH CONTINUOUS BEAD OF SEALANT UNDER FRAME. 4. INSTALL HEAD S.A.F. -LAP OVER JAMB S.A.F. 5. INSTALL BLDG. PAPER AT JAMB AND HEAD OVER S.A.F. 4. HEAD S.A.F. LAPPED OVER JAMB S.A.F. -LAP OVER WINDOW FIN 2. JAMB S.A.F. LAPPED OVER SILL S.A.F. - UNDER WINDOW FIN 3. INSTALL WINDOW 1. SILL S.A.F. OVER BLDG. PAPER -UNDER WINDOW FIN 5. BLDG. PAPER OVER HEAD AND JAMB S.A.F. BLDG. PAPER S.A.F. BLDG. PAPER S.A.F. SHIM SHIM S.A.F. BLDG. PAPER HEAD JAMB SILL 3 1 / 4 " 6" P.T. WOOD SILL OR OTHER TREATED MATERIAL OR CONCRETE (VARIES) SILL EXTENSION SILL PLATE BEHIND 22 GA. LEAD COATED COPPER THRESHOLD FLASHING PAN SELF ADHERING MEMBRANE OVER FLASHING FRAMING 1/4" RETURN 1" RETURN SLOPE PAN 1/4" PER FOOT MIN. SELF-ADHERING FLASHING BITUTHANE SLOPE PAN 1/4" PER FOOT MIN. 1/4" RETURN POST BITUTHANE WRAP OVER FLASHING P.T. WOOD SILL OR OTHER TREATED MATERIAL 6" 3 1 / 4 " 6" 3 1 / 4 " BITUTHANE WRAP OVER FLASHING 22 GA. LEAD COATED COPPER THRESHOLD FLASHING PAN SILL EXTENSION P.T. WOOD SILL OR OTHER TREATED MATERIAL BITUTHANE SLOPE PAN FLASHING 1/4" PER FOOT MIN. 1" RETURN 1/4" RETURN FRAMING 1 1/2" MIN. V.I.F. 1" MIN. 16 OZ. LEAD COATED COPPER BASE FLASHING SET ALL LAPS IN SEALANT FULLY SOLDERED END DAMN SOLDER ALL JOINTS WATER TIGHT 1/2" HEMMED EDGE 6" 6" 1 1/2" V.I.F. 4" 4" V.I.F. 6" V.I.F. 6" 1/2" HEMMED EDGE SOLDER ALL JOINTS WATERTIGHT 16 OZ. LEAD COATED COPPER BASE FLASHING SET ALL LAPS IN SEALANT LEAD COATED COPPER DRIP BITUTHANE STRIP S.A.F COPPER BITUTHANE STRIP GRAD 'D' BUILDING PAPER TYPICAL WATER PROOFING & FLASHING AT DOOR HEAD DRAIN MAT Th e s e d o c u m e n t s a r e t h e p r o p e r t y o f EA D . A n y u n a u t h o r i z e d u s e w i t h o u t t h e wr i t t e n c o n s e n t o f E A D i s p r o h i b i t e d b y la w . E A D d i s c l a i m s r e s p o n s i b i l i t y f o r th e s e d o c u m e n t s i f t h e y a r e u s e d w h o l e or i n p a r t a t a n y o t h e r l o c a t i o n a n d f o r an y o t h e r a p p l i c a t i o n o t h e r t h a n t h e or i g i n a l i n t e n t . I f y o u a r e n o t t h e in t e n d e d r e c i p i e n t , y o u a r e h e r e b y no t i f i e d t h a t a n y d i s s e m i n a t i o n , di s t r i b u t i o n o r r e p r o d u c t i o n o f t h e s e do c u m e n t s i s p r o h i b i t e d b y l a w . 350 MARKET STREET SUITE 309 BASALT, COLORADO 81621 PHONE: 970.300.3423 FAX: 415.358.5771 INFO@EIGELBERGER.COM Co p y r i g h t c 2 0 1 8 b y E I G E L B E R G E R A R C H I T E C T U R E & D E S I GN SCALE: Plot Date Drawn By Checked By Project No. CLIENT REVIEW: REVIEWED AND APPROVED FOR DESIGN INTENT: CLIENT UNDERSTANDS THE DESIGN INTENT OF THE DOCUMENT. CLIENT APPROVES DESIGN INTENT. ARCHITECT WILL PROCEED WITH DETAILS AND COORDINATION WITH CONTRACTOR PER SIGN OFF ON DOCUMENT. NOTE: ANY CHANGES TO THE APPROVED DRAWINGS BY CLIENT ARE ADDITIONAL SERVICE PER CONTRACT. ARCHITECT TO PICKUP CORRETIONS AS NOTED CLIENT SIGNATURE: ___________________________ DATE OF APPROVAL: __________________________ Date Issue 3" = 1'-0" BI M 3 6 0 : / / 1 9 0 1 7 - 1 3 4 B l e e k e r / 1 9 0 1 7 _ 1 3 4 E B l e e k e r S t _C E N T R A L . r v t 5/11/2021 3:16:21 PM A.6.11 FLASHING DETAILS 13 4 E A S T B L E E K E R AS P E N , C O 19017 HANNAH-HUNT MOELLER Checker A.6.11 1 BITUTHANE FLASHING DETAILS, TYP. A.6.11 3 PAN FLASHING AT DOOR, TYP. A.6.11 2 PAN FLASHING AT POST, TYP. A.6.11 4 PAN FLASHING AT WINDOW, TYP. A.6.11 5 PAN FLASHING AT WINDOW AXON, TYP. A.6.11 6 DOOR PAN FLASHING AXON, TYP. A.6.11 7 DRIP DETAIL AT HEAD, TYP. 8/12/2020 PERMIT