Loading...
HomeMy WebLinkAboutFile Documents.205 E Durant Ave.0127-2023-BRES (9)Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: FEATURES • Variable speed INVERTER-driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 52 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection MXZ-3C30NA32.5-TON MULTI-ZONE INVERTER HEAT-PUMP SYSTEM 10/23/2023 Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: MXZ-3C30NA3 test Cooling1 (Non-Ducted // Mix // Ducted) Maximum Capacity BTU/H 28,400 // 28,400 // 28,400 Rated Capacity BTU/H 28,400 // 27,900 // 27,400 Minimum Capacity BTU/H 11,600 // 11,300 // 11,000 Maximum Power Input W 2,680 // 2,680 // 2,680 Rated Power Input W 2,680 // 2,760 // 2,840 Power Factor (208V, 230V)%99.0, 99.0 // 99.0, 99.0 // 99.0, 99.0 Heating at 47°F2 (Non-Ducted // Mix // Ducted) Maximum Capacity BTU/H 36,000 // 36,000 // 36,000 Rated Capacity BTU/H 28,600 // 28,100 // 27,600 Minimum Capacity BTU/H 18,100 // 18,300 // 18,500 Maximum Power Input W 3,300 // 3,300 // 3,300 Rated Power Input W 2,150 // 2,185 // 2,220 Power Factor (208V, 230V)%98.5, 98.5 // 98.4, 98.4 // 98.2, 98.2 Heating at 17°F3 (Non-Ducted // Mix // Ducted) Maximum Capacity BTU/H 21,000 // 21,000 // 21,000 Rated Capacity BTU/H 17,800 // 17,800 // 17,800 Maximum Power Input W 2,740 // 2,780 // 2,820 Rated Power Input W 1,760 // 1,830 // 1,900 Heating at 5°F4 (Non-Ducted // Mix // Ducted) Maximum Capacity BTU/H 18,200 // 18,200 // 18,200 Maximum Power Input W 2,310 // 2,355 // 2,400 Efficiency (Non-Ducted // Mix // Ducted) SEER | SEER2 19.0 // 17.6 // 16.2 | 19.00 // 17.60 // 16.20 EER1 | EER21 10.6 // 10.12 // 9.65 | 10.60 // 10.10 // 9.60 HSPF (IV) | HSPF2 (IV)10.6 // 10.1 // 9.6 | 9.3 // 9.05 // 8.8 COP at 47°F2 3.9 // 3.77 // 3.65 COP at 17°F at Maximum Capacity3 2.25 // 2.22 // 2.18 COP at 5°F at Maximum Capacity4 2.31 // 2.26 // 2.22 ENERGY STAR® Certified No // No // No Electrical Electrical Power Requirements Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range V AC 187-253 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR)kA 5 Recommended Fuse/Breaker Size A 25 Recommended Wire Size AWG 14 Minimum Circuit Ampacity A 22.1 Maximum Overcurrent Protection A 25 Fan Motor Full Load Amperage A 2.43 Outdoor unit Airflow Rate (Cooling / Heating)CFM 2,287 / 2,382 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling1 dB(A)52 Sound Pressure Level, Heating2 dB(A)56 Compressor Type DC INVERTER-driven Twin Rotary Compressor Model SNB220FQGMC Compressor Rated Load Amps A 12 Compressor Locked Rotor Amps A 13.7 Compressor Oil Type // Charge oz.FV50S // 23.7 Base Pan Heater Optional Unit Dimensions W: In. [mm]37-13/32 [950] D: In. [mm]13 [330] H: In. [mm]31-11/32 [796] Package Dimensions W: In. [mm]40-15/16 [1,040] D: In. [mm]17-11/16 [450] H: In. [mm]40-11/16 [1,033] Unit Weight Lbs.[kg]137 [62] Package Weight Lbs.[kg]157 [71] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum*A)°FDB 115 / 14 Cooling Thermal Lock-out / Re-start Temperatures °FDB 10.4 / 14 Heating Intake Air Temp (Maximum / Minimum)°FWB 65 / 5 Heating Thermal Lock-out / Re-start Temperatures °FDB 1.4 / 5 Refrigerant Charge Lbs, oz 6.0, 13.0 Chargeless Piping Length Ft. [m]98.0 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m]0.216 [20] NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. *A 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. 10/23/2023 SPECIFICATIONS: MXZ-3C30NA3 Indoor unit connection Maximum Number of Connected IDU 3 Minimum Number of Connected IDU 2 Minimum connected capacity BTU/H 12,000 Maximum connected capacity BTU/H 36,000 Piping Liquid Pipe Size O.D. (Flared)In.[mm]A,B,C: 1/4 [A,B,C: 6.35] Gas Pipe Size O.D. (Flared)In.[mm]A: 1/2; B,C: 3/8 [A: 12.72; B,C: 9.52] Total Piping Length Ft. [m]230 [70] Maximum Height Difference, ODU above IDU Ft. [m]49 [15] Maximum Height Difference, ODU below IDU Ft. [m]49 [15] Farthest Piping Length from ODU to IDU Ft. [m]82 [25] Maximum Number of Bends for IDU 70 NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. *A 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 10/23/2023 Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide (1 Piece) PAC-SH96SG-E Ball Valve Refrigeration Ball Valve - 1/2” BV12FFSI2 Refrigeration Ball Valve - 1/4” BV14FFSI2 Refrigeration Ball Valve - 3/8” BV38FFSI2 Refrigeration Ball Valve - 5/8” BV58FFSI2 Control Wire M-Net Control Wire, 1,000’ Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) CW162S-1000 M-Net Control Wire, 250’ Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) CW162S-250 Drain Socket Drain Socket PAC-SG60DS-E Hail Guards Hail Guard HG-A9 M-NET Converter M-NET Converter PAC-IF01MNT-E Mini-Split Wire 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll SW144-250 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll SW144-50 16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 16 Gauge, 4 wire MiniSplit Cable—250 ft. roll SW164-250 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll SW164-50 Mounting Pad Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic DSD-400P Port Adapter Adaptor: 1/2” x 3/8” MAC-A455JP-E Adaptor: 1/2” x 5/8” MAC-A456JP-E Adaptor: 3/8” x 1/2” MAC-A454JP-E Adaptor: 3/8” x 5/8” PAC-SG76RJ-E Stand 18” Single Fan Stand QSMS1801M 24” Single Fan Stand QSMS2401M Condenser Wall Bracket QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish QSWBSS Outdoor Unit Stand — 12” High QSMS1201M OUTDOOR UNIT ACCESSORIES: MXZ-3C30NA3 10/23/2023 Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. FORM# MXZ-3C30NA3 - 202206 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Unit: inch (mm) Lock nut Conduit plates Conduit connector OUTDOOR UNIT DIMENSIONS: MXZ-3C30NA3 10/23/2023