Loading...
HomeMy WebLinkAboutFile Documents.205 E Durant Ave.0127-2023-BRES (10)NOBLE® RESIDENTIAL BOILER Submittal Sheet NKB-Sub-02 Job Name: __________________________________ Location: __________________________________ Engineer: __________________________________ Agent/Wholesaler: ______________________________ Contractor: __________________________________ NOTES: Model No. __________________________________ Type Gas: __________________________________ Equipment Tag(s): _____________________________________________ _____________________________________________ NOBLE® RESIDENTIAL CONDENSING BOILER MODELS NKB080-199 Smart Control™ Features » SMART CONTROL Digital Operating Control LCD Display with words, not codes » Outdoor Reset Control with Outdoor Air Sensor » Programmable System Efficiency Optimizers » Three Pump Control System Pump Boiler Pump DHW Pump » High-Voltage Junction Box 120 VAC / 60 Hertz / 1 Phase Power Supply » Low Voltage Terminal Strip Flow Switch Contacts Low-Water Cutoff Connection System Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts » Time Clock for Data Logging Last 10 Lockouts » Low-Water Flow Safety Control & Indication » Password Security » Built-in Cascading Sequencer for up to 8 units Standard Features » Modulating Burner with 10:1 Turndown Direct-Spark Ignition Low-NOx Operation » ASME Stainless Steel Heat Exchanger » Vertical & Horizontal Direct-Vent PVC, CPVC, Polypropylene or SS Venting up to 100 feet » Condensate Trap » California Code Compliant » Other Features Automatic Reset High Limit Adjustable High Limit w/Manual Reset Wall-Mount Bracket Zero Clearances to Combustible Materials See Warranty for Details: 10 Year HEX Warranty 5 Year Parts Warranty Optional Equipment Low-Water Cutoff w/Manual Reset & Test Concentric Vent Kit Condensate Neutralization Kit Sidewall Vent Termination Floor Stand Flow Switch Wireless Outdoor Sensor Nat to LP Gas Conversion Kit 10/23/2023 A B E G D H I F L M N K J O P C FLUEAIR INTAKE RELIEF VALVE GAS WATER IN WATER OUT CONDENSATE HIGH VOLTAGE CONNECTIONS 5/19—Printed in U.S.A. Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com INPUT Heating Model Min Max Capacity Net Number MBH MBH AFUE % MBH MBH A B C D E F G H NKB080N 8.3 80 95.0 74 64 24” 17-1/4” 17-1/4” 2-1/4” 5-1/8” 8-1/2” 5-1/8” 1-1/2” NKB110N 11 110 95.0 102 89 24” 17-1/4” 18” 2-3/4” 2-7/8” 9” 5-1/2” 2-7/8” NKB150N 15.0 150 95.0 139 125 24” 17-1/4” 18” 4-1/2” 2-3/4” 9-1/8” 11-3/4” 4-1/2” NKB199N 19.9 199 95.0 185 161 24” 17-1/4” 18” 4-1/8” 2-3/4” 9-3/8” 11-1/2” 4” Model Shipping Number Gas Water Air Vent Wt. (continued) I J K L M N O P Conn. Conn. Inlet Size (lbs.) NKB080N 1-1/2” 6-3/8” 12-5/8” 5-1/8” 4-5/8” 8-1/2” 1-1/2” 2-1/2” 1/2” 1” 2” 2” 120 NKB110N 2-7/8” 7-3/4” 13-1/8” 2-7/8” 5-1/2” 9” 2” 3” 1/2” 1” 3” 3” 126 NKB150N 4-1/2” 2-7/8” 13-1/8” 3” 5-3/8” 9-1/8” 1-7/8” 4-5/8” 1/2” 1” 3” 3” 132 NKB199N 4” 2-3/4” 13-1/2” 2-7/8” 5-1/2” 9-1/4” 1-3/8” 1-3/8” 1/2” 1” 3” 3” 140 NOTES: • Information subject to change without notice. Change “N” to “L” for LP gas models. • The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. ® FIRE TUBE • The ratings have been determined under the provisions governing forced draft burners. • Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. DIMENSIONS & SPECIFICATIONS 10/23/2023