Loading...
HomeMy WebLinkAboutFile Documents.500 W Smuggler St.0158-2023-BRES (3) APPLICATION ACCEPTED DATE: ?0'3-:' 7 PERMIT NUMBER: 0158-2023-BRES Field Plan Set Must Be Printed In Color �10k'l COMMUNITY DEVELOPMENT DEPARTMENT 44104:, CITY OF ASPEN ,�gl\t BUILDING PERMIT COVERSHEET PERMIT NO.0158-2023-BRES CITY OF CITY OFASPEN f ASPEN OWNER CHGH ASPEN PROPERTIES LLC PROPERTY INFORMATION ADDRESS 500 W SMUGGLER ST These plans mU e�ept at the ADDRESS 500 W SMUGGLER ST UNIT: building site or inspection PARCEL ID: 273512404009 LEGAL DESCRIPTION: CITY AND TOWNSITE OF ASPEN PARCEL ID 273512404009 delays may occur.Construction OWNER CHGH ASPEN PROPERTIES LLC shall conform to these plans.All PERMIT CONTRACTOR: changes shall be approved by the building official. DESCRIPTION OF WORK Add Snowmelt walkwa s 80 SF+135F+13 SF SEPARATE PERMITS ARE y REQUIRED FOR ELECTRICAL, PLUMBING,MECHANICAL,OR FIRE SPRINKLER WORK Amenity Energy Use Approved(2021 CODE) SMOKE ALARMS AND USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? NO 0 RREMP ❑ CREMP CARBON MONOXIDE DETECTORS REQUIRED PERMIT#:0158-2023-BRES DATE:_1/23/2 THROUGHOUT DWELLING UNIT PER CITY OF ASPEN CLASS OF WORK Residential FIRE SPRINKLER TYPE NVP4 13 R SNOWMELT:_106 sq ft MUNICIPAL CODE 8.15 POOL: SPA: BUILDING TYPE(IRC) Two family REQUIRED SPECIAL Other HEAT TAPE:INSPECTIONS It should be known that this review shall HEAT MAT: not relieve the applicant of their Ex HEATERS: responsibility to comply with the CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table Ex FIREPLACES: requirements of the Ciry of Pursuant Aspen 1Pt Municipal Code. to In FIREPLACES: Sec.26.104.050,any permit or approval issued in error or otherwise not in OCCUPANCY GROUP(IBC) R-3 WORK CHANGES BUILDING IV REMP SHEET(S): conformity with the requirements of this shall b FOOTPRINT? MINIMUM BOILER AFUE: Title,or approvaliss�ledslarly,inrr any upon oir OFFSET: REMP PAYMENT as a result of,a materially false CODE EDITIONS 2021 IBC TOTAL SPA SQ.FT. REVIEWED BY:_LINZHID statement or representation made in the process of obtaining the permit or development approval shall,likewise, be void.Any person having received a SNOWMELT MANDATORY REQ'S. void or voidable permit or approval OTHER CODE EDITIONS 2021 1EBC TOTAL SNOWMELT SQ.FT. 106 All snowmelt systems shall meet the following per(Ordinance 1 Series2023): shall not be relieved from having to -Any portions in the Right of Way must be on a separate zone.A ROW permit and Permanent Encroachment License are required. comply with all applicable terms and -R10 insulation shall be installed under the area to be snow melted or R5 4 conditions of this Title and the City shall (insulation elan be installed under and et the slab edges not be estopped from fully enforcing Automatic controls configured for stem shut off when surface temperature and HISTORIC PROPERTY? No TOTAL POOL SQ.FT. q y p air temperature are above 40°F and no precipitation is falling. same. Inspection by testing hydrostatically at 1%times max system design pressure, but not less then 100psi,for 15 minutes.(2021 IMC Sec.1208.1) FIRE SPRINKLER EXISTING? Yes r01/23/2024 J FORC0111MIN'LINK E linzhid 1. Exterior Energy Use Calculations Annual BTU Energy Use Offset required A MID-INSPECTION AND Application Efficiency Budget % Offset PV kW Payment in lieu FINALINSPECTION IS 1. In-Slab Snowmelt 106 sq. ft. REQUIRED TO RECEIVE A Calculated- Total area of proposed in-slab snowmelt and heat source efficiency- LETTER OF (1a) Exempt In-Slab Snowmelt: 0 sq. ft. COMPLETENESS Enter area of exempt in-slab snowmelt. COA to verify. (1b)Non-Exempt In-Slab Gas Snowmelt: 106 sq. ft. 92-0% 9,547,259 100'/, 1-87 $6,062.64 Enter total area of in-slab snowmelt less the exempt area. D EV 1))luisp (1c)Non-Exempt In-Slab Electric Snowmelt: 0 sq. ft. 100.0% - 100% 0.00 $0.00 n01/02/2024 ...) Enter total area of in-slab snowmelt less the exempt area. ZONING