HomeMy WebLinkAboutFile Documents.500 W Smuggler St.0158-2023-BRES (3) APPLICATION ACCEPTED DATE: ?0'3-:' 7 PERMIT NUMBER: 0158-2023-BRES
Field Plan Set Must Be Printed In Color �10k'l
COMMUNITY DEVELOPMENT DEPARTMENT 44104:, CITY OF ASPEN ,�gl\t
BUILDING PERMIT COVERSHEET PERMIT NO.0158-2023-BRES CITY OF
CITY OFASPEN f ASPEN
OWNER CHGH ASPEN PROPERTIES LLC
PROPERTY INFORMATION
ADDRESS 500 W SMUGGLER ST These plans mU e�ept at the
ADDRESS 500 W SMUGGLER ST UNIT: building site or inspection
PARCEL ID: 273512404009 LEGAL DESCRIPTION: CITY AND TOWNSITE OF ASPEN PARCEL ID 273512404009 delays may occur.Construction
OWNER CHGH ASPEN PROPERTIES LLC shall conform to these plans.All
PERMIT CONTRACTOR: changes shall be approved by
the building official.
DESCRIPTION OF WORK Add Snowmelt walkwa s 80 SF+135F+13 SF SEPARATE PERMITS ARE
y REQUIRED FOR ELECTRICAL,
PLUMBING,MECHANICAL,OR
FIRE SPRINKLER WORK
Amenity Energy Use Approved(2021 CODE)
SMOKE ALARMS AND
USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? NO 0 RREMP ❑ CREMP CARBON MONOXIDE
DETECTORS REQUIRED
PERMIT#:0158-2023-BRES DATE:_1/23/2 THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
CLASS OF WORK Residential FIRE SPRINKLER TYPE NVP4 13 R SNOWMELT:_106 sq ft MUNICIPAL CODE 8.15
POOL:
SPA:
BUILDING TYPE(IRC) Two family REQUIRED SPECIAL Other
HEAT TAPE:INSPECTIONS It should be known that this review shall
HEAT MAT: not relieve the applicant of their
Ex HEATERS: responsibility to comply with the
CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table Ex FIREPLACES: requirements of the Ciry of Pursuant Aspen
1Pt Municipal Code. to
In FIREPLACES: Sec.26.104.050,any permit or approval
issued in error or otherwise not in
OCCUPANCY GROUP(IBC) R-3 WORK CHANGES BUILDING IV REMP SHEET(S): conformity with the requirements of this
shall b FOOTPRINT? MINIMUM BOILER AFUE: Title,or approvaliss�ledslarly,inrr any
upon oir
OFFSET: REMP PAYMENT as a result of,a materially false
CODE EDITIONS 2021 IBC TOTAL SPA SQ.FT. REVIEWED BY:_LINZHID statement or representation made in
the process of obtaining the permit or
development approval shall,likewise,
be void.Any person having received a
SNOWMELT MANDATORY REQ'S. void or voidable permit or approval
OTHER CODE EDITIONS 2021 1EBC TOTAL SNOWMELT SQ.FT. 106 All snowmelt systems shall meet the following per(Ordinance 1 Series2023): shall not be relieved from having to
-Any portions in the Right of Way must be on a separate zone.A ROW permit
and Permanent Encroachment License are required. comply with all applicable terms and
-R10 insulation shall be installed under the area to be snow melted or R5 4 conditions of this Title and the City shall
(insulation elan be installed under and et the slab edges not be estopped from fully enforcing
Automatic controls configured for stem shut off when surface temperature and
HISTORIC PROPERTY? No TOTAL POOL SQ.FT. q y p
air temperature are above 40°F and no precipitation is falling. same.
Inspection by testing hydrostatically at 1%times max system design pressure,
but not less then 100psi,for 15 minutes.(2021 IMC Sec.1208.1)
FIRE SPRINKLER EXISTING? Yes
r01/23/2024 J
FORC0111MIN'LINK E
linzhid
1. Exterior Energy Use Calculations Annual BTU
Energy Use Offset required A MID-INSPECTION AND
Application Efficiency Budget % Offset PV kW Payment in lieu FINALINSPECTION IS
1. In-Slab Snowmelt 106 sq. ft. REQUIRED TO RECEIVE A
Calculated- Total area of proposed in-slab snowmelt and heat source efficiency- LETTER OF
(1a) Exempt In-Slab Snowmelt: 0 sq. ft. COMPLETENESS
Enter area of exempt in-slab snowmelt. COA to verify.
(1b)Non-Exempt In-Slab Gas Snowmelt: 106 sq. ft. 92-0% 9,547,259 100'/, 1-87 $6,062.64
Enter total area of in-slab snowmelt less the exempt area. D EV 1))luisp
(1c)Non-Exempt In-Slab Electric Snowmelt: 0 sq. ft. 100.0% - 100% 0.00 $0.00 n01/02/2024 ...)
Enter total area of in-slab snowmelt less the exempt area. ZONING